hf systematics team sync aaf recirculation care solutions
TRANSCRIPT
![Page 1: HF SYSTEMATICS Team Sync AAF Recirculation Care Solutions](https://reader033.vdocuments.mx/reader033/viewer/2022042603/6262b2ee263cba2a8e7aeefa/html5/thumbnails/1.jpg)
THE WORLD LEADER FOR SAFE-AIR
HF SYSTEMATICS
Team Sync-AAF
Recirculation Care-Solutions
VariCel®I
AstroCel® VXL
AmAir®/C / AmAir®300E
INTIR NATIO N AL
Bringing clean air to life: https://sync-global.com/aaf
![Page 2: HF SYSTEMATICS Team Sync AAF Recirculation Care Solutions](https://reader033.vdocuments.mx/reader033/viewer/2022042603/6262b2ee263cba2a8e7aeefa/html5/thumbnails/2.jpg)
HF Systems
For Creation of "Isolation Zones" to Reduce
the Risk of Airborne Infection
AAF International is a leading supplier of negative pressure HEPA filtration equipment, with more than 25,000 air filtration systems in use today.
Our HEPA Filtration Systems are designed to create airborne infection isolation rooms in the healthcare setting. These systems can be used to meet certain engineering provisions from the 2003 CDC Guidelines for Healthcare Infection Control.
AAF HEPA Filtration Systems can be used for negative pressure environments or recirculation/dilution. All models are classified as Class II medical devices.
Our user-friendly systems are designed to provide the highest level of protection at an economical price. Each system features quiet, energy-saving motorized impellers, specially designed 99.99% gel seal HEPA filter, prefilter, aircraft-type cabinet construction, locking control and filter compartment, and attractive design. The HEPA and pre filter are UL listed and the fan is CE certified. Prefilters for the removal of smoke and odors are also available.
AP Portable HF-Systems
The AstroPure is the most versatile AAF model, with numerous infection control applications for the healthcare facility. It can be used as a portable system for movement from room to room on its stable, easy-to-move caster cart. If necessary, it can be removed from its cart for operation as a fixed
The AstroPure can be utilized in any of three operating modes:
• 1 00% exhaust*• Need based variable exhaust based on the
application• 100% recirculation
Option 1 and 2 can be supplied with an optional flexible ducting.
Dual (top and back) exhaust outlets further add to the versatility of the AstroPure.
The AstroPure is designed specifically to enable a healthcare facility to quickly and inexpensively convert a standard patient room to a negative pressure isolation room. It can also be rolled into an ER, OR, ICU, or radiology suite when an airborne infection isolation room is required. It can be used as a recirculating device in outpatient clinics, waiting areas, and other common use areas where the status of patients and visitors is unknown.
This powerful system delivers up to 500-2000 CFM operating airflow at the "HIGH" speed setting. As a result, the AstroPure can typically provide above 12 air changes per hour in rooms up to 2,500 cubic feet. Variable speed controls enable the AstroPure to be run at lower speeds where less airflow is required. With fan regulation, the delivered volume can go upto 2000 CFM.
Page 1
https://sync-global.com/aaf
![Page 3: HF SYSTEMATICS Team Sync AAF Recirculation Care Solutions](https://reader033.vdocuments.mx/reader033/viewer/2022042603/6262b2ee263cba2a8e7aeefa/html5/thumbnails/3.jpg)
AP500
Flexible ducting possibility for 100% exhaust
AstroCel® 11
AmAir®/C / AmAir®300E
MegaPleat® M8
Page2
https://sync-global.com/aaf
![Page 4: HF SYSTEMATICS Team Sync AAF Recirculation Care Solutions](https://reader033.vdocuments.mx/reader033/viewer/2022042603/6262b2ee263cba2a8e7aeefa/html5/thumbnails/4.jpg)
AP500-11
Flexible ducting possibility for 100% exhaust
Page3
AstroCel® 11
AmAir®300E
https://sync-global.com/aaf
![Page 5: HF SYSTEMATICS Team Sync AAF Recirculation Care Solutions](https://reader033.vdocuments.mx/reader033/viewer/2022042603/6262b2ee263cba2a8e7aeefa/html5/thumbnails/5.jpg)
AP500-Ill
Flexible ducting possibility for 100% exhaust
AmAir®300E
Page4
https://sync-global.com/aaf
![Page 6: HF SYSTEMATICS Team Sync AAF Recirculation Care Solutions](https://reader033.vdocuments.mx/reader033/viewer/2022042603/6262b2ee263cba2a8e7aeefa/html5/thumbnails/6.jpg)
AP 2000
Flexible ducting possibility
for 100% exhaust
VariCel® I
AstroCel® VXL
vW'\4' -��Jt._L� �(
�D_ ..._
MegaPleat® MB
Page5
https://sync-global.com/aaf
![Page 7: HF SYSTEMATICS Team Sync AAF Recirculation Care Solutions](https://reader033.vdocuments.mx/reader033/viewer/2022042603/6262b2ee263cba2a8e7aeefa/html5/thumbnails/7.jpg)
Technical SpecificationsName of Puificat1on System
1)1)8 P<>rtallle / S1and alone floor s1'ln<lng int ""'1eble / stand al0<>e ll00r s1andlng unit Stand alone floor s1'ln<:lng int
OveralOlmenSIOl'I
Air Aow �ily 500 CFM 500 CFM 500 CFM
Eloctoctty and Power Constn¥Jtion
Motot £C C<nlrltugal Fan EC Centrifugal Fan EC C<nlrllugal Fan
Eslknated Shipment we!!ll>t Is 54 Kg Estimated "'1.,mont weigh! Is 54 ICll Estmated shipmen! weight Is 54 kg
AmAi .. /C/ -OOE NA NA
99tlll&lial MPPS EN1822
<53.7 dB <53.7 dB <53.7 dB
1 Year 1 Year 1 YMr
ov«a1 Weigl>!
Pre Flter
� Alter
Sy"1Em Elllctency
Sound Love!
UV light
Wanan1y A9alnst Manu1actlJ'lng Defects
Speed CO<>trol
UV-L
Portatle I stand alone lloor st•n� unn
2000CFM
EC Cenmlugal Fan
Est,m;,t<ld shipment weight Is 54 Kgs
Goonicidal lamp 200·280 nm
t.lPPSuperEr-11822
1 Year
Broad-spectrum germicidal UV light which has wavelengths between 200 and 400 nanometers (nm), is highly effective at killing bacteria and viruses by destroying the molecular bonds that hold their DNA together.
UVC light also emits very short ultraviolet UV vacuum with wavelengths which creates ozone. It comes with a protective glass to block harmful UV wave lenghts.
Violet Red
Va<uum Short W1.wc. lJV M tddkt W,lvt UV long Wlt'H!: UV UV nM·CI (UV-Bl IIJV-AI
100 184 200
,53 300 315
,80
Page6
400
(nm)
https://sync-global.com/aaf
![Page 8: HF SYSTEMATICS Team Sync AAF Recirculation Care Solutions](https://reader033.vdocuments.mx/reader033/viewer/2022042603/6262b2ee263cba2a8e7aeefa/html5/thumbnails/8.jpg)
MEGApleat® MB
Product Overview • Excellent as a pre-filter
• Low operating resistance saves energy
• Highest dust holding capacity
• Strongest construction
• Guaranteed consistent performance
• Patent-pending filter design
• Heavy-duty, galvanised expanded metal support grid
Specification
EN779
ASHRAE52.2
ISO 16890
Filter Depth (mm)
Media Type
G4
MERV8
Coarse60%
22, 44, 95
Synthetic
Frame Material
Special Size Available
Antimicrobial Available
Recomm. Rnal Resistance
Max Operating Temperature
Air Filtration Certificate
Moisture Resistant Beverage Board
Yes
No
250 Pa
93°c
UL900
Pre-Filter Information
Nominal Size Actual Size Inches mm
(W x H x D) (W x H x D)
24 X 24 X 2 I 594 X 594 X 44 I
Page 7
Rated Rated Initial Airflow Resistance (CMH) (Pa)
3,400 I 67
https://sync-global.com/aaf
![Page 9: HF SYSTEMATICS Team Sync AAF Recirculation Care Solutions](https://reader033.vdocuments.mx/reader033/viewer/2022042603/6262b2ee263cba2a8e7aeefa/html5/thumbnails/9.jpg)
THE WORLD LEADER IN CLEAN AIR SOLUTIONS
AA300E
Product Overview • Excellent as a pre-filter• Disposable pleated filter• Wide selection range• High loft media increases dust holding capacity• Expanded metal support grid increases the stability of the pleat pack
Specification
EN 779
ASHRAE 52.2
ISO 16890
Filter Depth (mm)
Media Type
Frame Material
Special Size Available
Antimicrobial Available
Recomm. Final Resistance
Max Operating Temperature
Air Filtration Certificate
Product Information
G4
MERV?
Coarse 70%
22,44,95
Non-Woven Cotton Synthetic Blend
Moisture Resistant Beverage Board
Yes
Optional
250 Pa
93°c
UL900
LNominal Size Actual Size
Media Inches mm
(W x H x D) (W x H x D)
44mm
300E I 24 X 24 X 2 594x594 X 44
Rated
Airflow
(CMH)
850
Rated Initial
Resistance
{Pa)
-- -
30
Page8
https://sync-global.com/aaf
![Page 10: HF SYSTEMATICS Team Sync AAF Recirculation Care Solutions](https://reader033.vdocuments.mx/reader033/viewer/2022042603/6262b2ee263cba2a8e7aeefa/html5/thumbnails/10.jpg)
THE WORLD LEADER IN CLEAN AIR SOLUTIONS
AA-2
/C
Product Overview
• Disposable filter for economical, effective, gas-phase and
particulate filtration• Economical solution to many gaseous contaminant problems
including odors
• Carbon
• Odor removal and corrosion control protection
• Easy to install
• Directly interchangeable with standard air filters
Specification
EN779
ASHRAE 52.2
Filter Depth (mm)
Media Type
Frame Material
Special Size Available
Antimicrobial Available
Recommended Filter Resistance
Max Operating Temperature
Air Filtration Certificate
Product Information
AmAir • IC
Nominal Size
Inches {W X H X D)
44mm
24 X 24 X 2
Page9
G4
MERV?
44
Carbon
Moisture Resistance Beverage Board
Yes
No
250 Pa
49°c
UL900
Actual Size mm
{W x H x D)
594 X 594 X44
Airflow Rated Initial
(CMH) Resistance (Pa)
3400 90
https://sync-global.com/aaf
![Page 11: HF SYSTEMATICS Team Sync AAF Recirculation Care Solutions](https://reader033.vdocuments.mx/reader033/viewer/2022042603/6262b2ee263cba2a8e7aeefa/html5/thumbnails/11.jpg)
THE WORLD LEADER IN CLEAN AIR SOLUTIONS
AsC®-II (GS)
Product Overview • Individually tested for certified performance• Reduces operation costs with lowest possible pressure drop
from microglass media
• Available in a range of efficiencies• Lightweight and compact
Specification
EN1822
Filter Deplll (mm)
Media Type
Frame Material
Separator Style
Gasket Material
Gasket Position
Faceguard
Recommended Final Resistance
Max Operating Temperature
Air Filtration Certificate
Efficiency
Product Information
Actual Size mm
(H x W x D)
592 X 592 X 117
Page 10
H14
Various
Fibreglass
Aluminium
Hot Melt
EPDM
Upstream, Both Sides
Both Sides
500Pa
7CY'C
UL900
99.995% at MPPS
,·
I
Rated
Airflow
(CMH)
850
I
• All HEPA Filters are-Auto Scan Tested as per EN1822
• All HEPA Filters are made in
cleanroom (Class 100,000)
tirfrn�,,_ri ~�
Rated Initial
Resistance
(Pa)
140
https://sync-global.com/aaf
![Page 12: HF SYSTEMATICS Team Sync AAF Recirculation Care Solutions](https://reader033.vdocuments.mx/reader033/viewer/2022042603/6262b2ee263cba2a8e7aeefa/html5/thumbnails/12.jpg)
THE WORLD LEADER IN CLEAN AIR SOLUTIONS
VCl®-1
Product Overview • Excellent performance in difficult operating conditions• Dual density media delivers longer life and the lowest
initial resistance • Designed to improve Indoor Air Quality • Water-resistant media ideal for installations in humid areas,
or where exposed to moisture• MERV 13 meet LEED® Project Certification
efficiency requirements
Specification
EN779 M6- F9
ASHRAE 52.2 MERV 11 - 15
ISO 16890 ePM 10 65%, ePM1 50%, 70%, 80%
Filter Depth (mm) 149, 292
Media Type Fibreglass
Frame Material (Standard) Galvanised Steel
Frame Material (Optiona� Particle Board, MDF, Plywood
Separalor Style Aluminium
Special Size Available Yes
Antimicrobial Available Optional
Header Type Single, Double, None Header
Recommended Final Resistance 450 Pa
Max Operating Temperature 120°C (SH & DH), 93°C (NH)
Air Filtration Certificate UL 900
Product Information
Actual Size mm
(HxWx D)
594 X 594 X 292
Rated
Airflow
(CMH) --
3400
Rated Initial
Resistance
(Pa)
80
==-
Page 11
https://sync-global.com/aaf
![Page 13: HF SYSTEMATICS Team Sync AAF Recirculation Care Solutions](https://reader033.vdocuments.mx/reader033/viewer/2022042603/6262b2ee263cba2a8e7aeefa/html5/thumbnails/13.jpg)
AP Range Detail-1.01A
• • 2 0
Stage1J 1: MegaPleat M8 (2"} 2: Amair (2"} 3: MegaPleat M8 v(4"} 4: AmAir (4"}
Stage2 __ _.. 1: Amair 2: Amair C 3: AmAirC+ 4: Varicel VXL 5: Varicel II
C: SAAF MD 0:NA
• • H2 0
Stage 3 ___ _,
H 1 : Astrocel I H2: Astrocel II H3: Astrocel Ill H4: Megacel I H5: Megacel II H6: Megacel Ill 0: NA
UV light __ __,
U: With UV Light 0: Without UV Light
Fan
1: EC190 2:EC225 3:EC250 4:EC315
• �
• 0
• A
T: TVOC V: Velocity
• 2
• G
l Outlet
S: Spigot G: Grill
Panel Thickness
1: 1 " 2: 2 "S: Single Skin
DP Measurement
A: Analog D: Digital P:DP
P: PM sensor 0: NA
Page 12
https://sync-global.com/aaf
![Page 14: HF SYSTEMATICS Team Sync AAF Recirculation Care Solutions](https://reader033.vdocuments.mx/reader033/viewer/2022042603/6262b2ee263cba2a8e7aeefa/html5/thumbnails/14.jpg)
Proven Expertise of AAF
AAF offers the most comprehensive SAFE-Air portfolio in theindustry, including particulate and gas-phase filters, to provide a customized clean air solution. Each solution-set is carefully designed, manufactured, and tested in full compliance with all applicable standards to meet the most challenging demands.
Email us at:
support.aaf@ sync-global.com
Call us at 011-450 33 577
Disclaimer: The information contained within this catalogue and the features offered are intended to
provide information about products available for purchase from AAF. AAF does not warrant the accuracy and reserves the right to make changes to the catalogue and its features at any time without notice.
https://sync-global.com/aaf