heyi electrical - deutsche messe agdonar.messe.de/exhibitor/hannovermesse/2017/l860329/sct... ·...

4
YUE QING HEYI ELECTRICAL CO.,LTD ADD:ShangYanHou Village,LiuShi Town,YueQing City,ZheJiang,CHINA TEL:86-577-62659558 FAX:86-577-62659558 contact :Mrs Bethy E-mail:[email protected] Web:www.transformerfactory.com YUE QING HEYI ELECTRICAL CO.,LTD

Upload: others

Post on 10-Jul-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HEYI ELECTRICAL - Deutsche Messe AGdonar.messe.de/exhibitor/hannovermesse/2017/L860329/sct... · 2017-04-20 · HACT split core current transformer provides precision messurement

YUE QING HEYI ELECTRICAL CO.,LTD

HEYI ELECTRICALProduct Catalog

www.transformerfactory.com

YUE QING HEYI ELECTRICAL CO.,LTD

ADD:ShangYanHou Village,LiuShi Town,YueQing City,ZheJiang,CHINA

TEL:86-577-62659558

FAX:86-577-62659558

contact :Mrs Bethy

E-mail:[email protected]

Web:www.transformerfactory.com

YU

E QIN

G H

EY

I ELE

CTR

ICA

L CO

.,LTD

Page 2: HEYI ELECTRICAL - Deutsche Messe AGdonar.messe.de/exhibitor/hannovermesse/2017/L860329/sct... · 2017-04-20 · HACT split core current transformer provides precision messurement

Split Core Current TransformersHEYI ELECTRICAL

Technique Indes

PA / UL94-V0

PBT

Silicon steel

Epoxy

Tie

-25℃~75℃

≤85%

Ul1015 20AWG Wire(twinsted wire)2.5m

Electrical Parameter Electrical Parameter

Frequency

Rated Input

Measuring range

Rated Output

Ratio

Phase angle

Dielectric strength

Insulation Resistance

50-2KHz

5A-1500A

10%In-120%In

0.333V(AC)or 0-500mA

≤±1.0%

≤±60min

2.5KV/1mA/1min

DC500V/100MΩ min

Case

Bobbin

Core

Internal structure

Construction

Operating Temp

Operating Humidity

Output Connection

Split Core Current TransformersHEYI ELECTRICAL

SCT Series

SCT range of split core current transformers have been specially designed to facilitate their installation in new or already existing net works.

They may be installed without opening any cable or bus-bar circuit. An ineternal precision resistor across the secondary winding of the ct provides

a low safe voltage output.

Current measurement, monitoring and protection for electrical wiring and equipment.

Current and power measurement for electric motors, lighting, air compressor, heating and venti lation system, air-condition equipment and

automation-control system.

Current, power and energy monitoring device.

Relay protection device.

Applications

FeaturesSplit core design, safe, easy to install, portable.

Wide inner window, allowing clamping of big cables or bus-bars

Wide range of sizes to accommodate all the existing installations

Wires plugs, Audio plugs, Power plugs and so on five kinds of plugs

White(S1)

Black(S2)

1 TurnPrimary

1 s

Circuit connection diagram

SCT Series

Current Ratio

Primary Current(A)

Max. Current(A)

Output

Load Resistance(Ω)

Class

Turns Ratio

Protection Level

Insulation Category

Operating Condition

Storage Condition

MODEL

50A/10mA 

50A

60A

10mA

50Ω

1.0

5000:1

7.5V0-P

SCT-19

100A/20mA 

100A

120A

20mA

50Ω

1.0

5000:1

7.5V0-P

200A/33.3mA

200A

240A

33.3mA

20Ω

1.0

6000:1

7.5V0-P

CATⅢ

-20℃~+50℃,≤85%RH,No condensation,IN-house&Any direction installable

-30℃~+50℃,≤85%RH,No condensation

200A/0.333V 

200A

240A

333mV

/ 

1.0

/

7.5V0-P

19.1

19.150.8

17

50.8

Current Ratio

Primary Current(A)

Max. Current(A)

Output

Load Resistance(Ω)

Class

Turns Ratio

Protection Level

Insulation Category

Operating Condition

Storage Condition

MODEL

200A/40mA

200A

240A

40mA 

50Ω

1.0

5000:1 

7.5V0-P

SCT-32

300A/60mA

300A 

360A

60mA

50Ω

1.0

5000:1 

7.5V0-P

400A/40mA

400A

480A

40mA 

50Ω

1.0

10000:1 

7.5V0-P

CATⅢ

-20℃~+50℃,≤85%RH,No condensation,IN-house&Any direction installable

-30℃~+50℃,≤85%RH,No condensation

400A/0.333V 

400A 

480A 

333mV

/ 

1.0

/ 

7.5V0-P 

600A/60mA 

600A

720A

60mA 

25Ω

1.0

10000:1

7.5V0-P

32.5

3282.5

26.2

85.5

YUE QING HEYI ELECTRICAL CO.,LTD009 www.transformerfactory.com E-Mail: [email protected] Tel: 86-577-62659558 010

Page 3: HEYI ELECTRICAL - Deutsche Messe AGdonar.messe.de/exhibitor/hannovermesse/2017/L860329/sct... · 2017-04-20 · HACT split core current transformer provides precision messurement

Split Core Current TransformersHEYI ELECTRICAL

Technique Indes

PA / UL94-V0

PBT

Silicon steel

Epoxy

Tie

-25℃~75℃

≤85%

Ul1015 20AWG Wire(twinsted wire)2.5m

Electrical Parameter Electrical Parameter

Frequency

Rated Input

Measuring range

Rated Output

Ratio

Phase angle

Dielectric strength

Insulation Resistance

50-2KHz

5A-1500A

10%In-120%In

0.333V(AC)or 0-500mA

≤±1.0%

≤±60min

2.5KV/1mA/1min

DC500V/100MΩ min

Case

Bobbin

Core

Internal structure

Construction

Operating Temp

Operating Humidity

Output Connection

Split Core Current TransformersHEYI ELECTRICAL

SCT Series

SCT range of split core current transformers have been specially designed to facilitate their installation in new or already existing net works.

They may be installed without opening any cable or bus-bar circuit. An ineternal precision resistor across the secondary winding of the ct provides

a low safe voltage output.

Current measurement, monitoring and protection for electrical wiring and equipment.

Current and power measurement for electric motors, lighting, air compressor, heating and venti lation system, air-condition equipment and

automation-control system.

Current, power and energy monitoring device.

Relay protection device.

Applications

FeaturesSplit core design, safe, easy to install, portable.

Wide inner window, allowing clamping of big cables or bus-bars

Wide range of sizes to accommodate all the existing installations

Wires plugs, Audio plugs, Power plugs and so on five kinds of plugs

White(S1)

Black(S2)

1 TurnPrimary

1 s

Circuit connection diagram

SCT Series

Current Ratio

Primary Current(A)

Max. Current(A)

Output

Load Resistance(Ω)

Class

Turns Ratio

Protection Level

Insulation Category

Operating Condition

Storage Condition

MODEL

50A/10mA 

50A

60A

10mA

50Ω

1.0

5000:1

7.5V0-P

SCT-19

100A/20mA 

100A

120A

20mA

50Ω

1.0

5000:1

7.5V0-P

200A/33.3mA

200A

240A

33.3mA

20Ω

1.0

6000:1

7.5V0-P

CATⅢ

-20℃~+50℃,≤85%RH,No condensation,IN-house&Any direction installable

-30℃~+50℃,≤85%RH,No condensation

200A/0.333V 

200A

240A

333mV

/ 

1.0

/

7.5V0-P

19.1

19.150.8

17

50.8

Current Ratio

Primary Current(A)

Max. Current(A)

Output

Load Resistance(Ω)

Class

Turns Ratio

Protection Level

Insulation Category

Operating Condition

Storage Condition

MODEL

200A/40mA

200A

240A

40mA 

50Ω

1.0

5000:1 

7.5V0-P

SCT-32

300A/60mA

300A 

360A

60mA

50Ω

1.0

5000:1 

7.5V0-P

400A/40mA

400A

480A

40mA 

50Ω

1.0

10000:1 

7.5V0-P

CATⅢ

-20℃~+50℃,≤85%RH,No condensation,IN-house&Any direction installable

-30℃~+50℃,≤85%RH,No condensation

400A/0.333V 

400A 

480A 

333mV

/ 

1.0

/ 

7.5V0-P 

600A/60mA 

600A

720A

60mA 

25Ω

1.0

10000:1

7.5V0-P

32.5

3282.5

26.2

85.5

YUE QING HEYI ELECTRICAL CO.,LTD009 www.transformerfactory.com E-Mail: [email protected] Tel: 86-577-62659558 010

Page 4: HEYI ELECTRICAL - Deutsche Messe AGdonar.messe.de/exhibitor/hannovermesse/2017/L860329/sct... · 2017-04-20 · HACT split core current transformer provides precision messurement

Split Core Current TransformersHEYI ELECTRICAL

SCT Series

Split Core Current TransformersHEYI ELECTRICAL

Current Ratio

Primary Current(A)

Max. Current(A)

Output

Load Resistance(Ω)

Class

Turns Ratio

Protection Level

Insulation Category

Operating Condition

Storage Condition

MODEL

500A/25mA

500A

600A

25mA 

50Ω

1.0

20000:1

7.5V0-P

SCT-52

600A/30mA

600A 

720A

30mA

50Ω

1.0

20000:1 

7.5V0-P

1000A/50mA

1000A

1200A

50mA 

50Ω

1.0

20000:1 

7.5V0-P

CATⅢ

-20℃~+50℃,≤85%RH,No condensation,IN-house&Any direction installable

-30℃~+50℃,≤85%RH,No condensation

800A/0.333V 

800A

960A

333mV 

/

1.0

/ 

7.5V0-P 

1500A/75mA 

1000A

1200A

50mA 

25Ω

1.0

20000:1 

7.5V0-P

52

51.5122 128

30

Accuracy class characteristics:a) classes 0.2; 0.5; 1 b) comparison of classes 0.5 and 0.5S

-3.5

-2.5

-1.5

-0.5

0.5

1.5

2.5

3.5

5% 20% 100% 120%

-2

-1.5

-1

-0.5

0

0.5

1

1.5

2

1% 5% 20% 100% 120%

0,2 0,5

0,5 0,5S

Ipn [%] Ipn [%]

,

1

,

,

,

,

,

,

, ,

,

,

Current error [%]

,

Current error [%]

HACT Series

HACT split core current transformer provides precision messurement for energy monitoring applications to sensing power loading equipment

without interrupting the lines. It has been specifically designed to be easy to open and yet maintain the accuracy required for intelligent meter,

quick to fit around cables.

FeaturesReliable locking mechanism, safe, easy to install, portable.

Clamp On ergonomic design

Precision measurement and low phase shift

Wires plugs, Audio plugs, Power plugs and so on five kinds of plugs

Circuit connection diagram

Clamping Diodc

DIAGRAM

Current measurement, monitoring and protection for electrical wiring and equipment.

Current and power measurement for electric motors, lighting, air compressor, heating and ventilation system, air-condition equipment and automation-control system.

Current, power and energy monitoring device.

Relay protection device.

Applications

YUE QING HEYI ELECTRICAL CO.,LTD011 www.transformerfactory.com E-Mail: [email protected] Tel: 86-577-62659558 012