hermpac

29
SCALE ISSUED DATE DRAWING www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE Cavity Fix Bevel Back Weatherboard System @ A4 20/12/11 HC-BEVEL-000 Drawing Index HP DRAWING INDEX - HC-BEVEL-000 HP DRAWING INDEX - HC-BEVEL-000 HP DRAWING INDEX - HC-BEVEL-000 HP DRAWING INDEX - HC-BEVEL-000 Product Product Product Product Suffix Suffix Suffix Suffix Dwg No. Dwg No. Dwg No. Dwg No. Detail Detail Detail Detail Description Description Description Description Issued Issued Issued Issued HC BEVEL 000 HC-BEVEL-000 Drawing Index 20/12/11 HC BEVEL 100 HC-BEVEL-100 Bevel Back Weatherboard System Profiles 20/12/11 HC BEVEL 101 HC-BEVEL-101 Bevel Back Weatherboard System Profiles 20/12/11 HC BEVEL 200 HC-BEVEL-200 Window Head Detail, Aluminium Joinery 20/12/11 HC BEVEL 201 HC-BEVEL-201 Window Sill Detail, Aluminium Joinery 20/12/11 HC BEVEL 202 HC-BEVEL-202 Window Jamb Detail, Aluminium Joinery 20/12/11 HC BEVEL 210 HC-BEVEL-210 Door Head Detail Aluminium Joinery 20/12/11 HC BEVEL 211 HC-BEVEL-211 Door Sill Detail, Aluminium Joinery 20/12/11 HC BEVEL 212 HC-BEVEL-212 Door Jamb Detail, Aluminium Joinery 20/12/11 HC BEVEL 220 HC-BEVEL-220 Window Head Detail, Timber Joinery 20/12/11 HC BEVEL 221 HC-BEVEL-221 Window Sill Detail, Timber Joinery 20/12/11 HC BEVEL 222 HC-BEVEL-222 Window Jamb Detail, Timber Joinery 20/12/11 HC BEVEL 300 HC-BEVEL-300 Internal Corner HP110 20/12/11 HC BEVEL 301 HC-BEVEL-301 Internal Corner Scribed 20/12/11 HC BEVEL 302 HC-BEVEL-302 Internal Corner Boxed 20/12/11 HC BEVEL 400 HC-BEVEL-400 External Corner Boxed 20/12/11 HC BEVEL 401 HC-BEVEL-401 External Corner Soaker 20/12/11 HC BEVEL 410 HC-BEVEL-410 General Detail Cavity Fix, Stain Finish 20/12/11 HC BEVEL 411 HC-BEVEL-411 General Detail Cavity Fix, Paint Finish 20/12/11 HC BEVEL 500 HC-BEVEL-500 Base OF Wall, Concrete 20/12/11 HC BEVEL 501 HC-BEVEL-501 Base Of Wall, Timber 20/12/11 HC BEVEL 600 HC-BEVEL-600 Roof/Wall Junction 20/12/11 HC BEVEL 601 HC-BEVEL-601 Barge Detail, Overhang 20/12/11 HC BEVEL 602 HC-BEVEL-602 Eaves Detail, Overhang 20/12/11 HC BEVEL 603 HC-BEVEL-603 Eaves Detail, No Overhang 20/12/11 HC BEVEL 700 HC-BEVEL-700 Parapet Detail 20/12/11 HC BEVEL 800 HC-BEVEL-800 Meter Box Detail 20/12/11 HC BEVEL 801 HC-BEVEL-801 Pipe Penetration Detail 20/12/11 HC BEVEL 802 HC-BEVEL-802 Pipe Penetration Plan Detail 20/12/11 DRAFT Copyright Herman Pacific

Upload: brendan-laurence

Post on 23-Mar-2016

233 views

Category:

Documents


1 download

DESCRIPTION

Hermapc details

TRANSCRIPT

Page 1: Hermpac

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

@ A4 20/12/11

HC-BEVEL-000Drawing Index

HP DRAWING INDEX - HC-BEVEL-000HP DRAWING INDEX - HC-BEVEL-000HP DRAWING INDEX - HC-BEVEL-000HP DRAWING INDEX - HC-BEVEL-000

ProductProductProductProduct SuffixSuffixSuffixSuffix Dwg No.Dwg No.Dwg No.Dwg No. DetailDetailDetailDetail DescriptionDescriptionDescriptionDescription IssuedIssuedIssuedIssued

HC BEVEL 000 HC-BEVEL-000 Drawing Index 20/12/11

HC BEVEL 100 HC-BEVEL-100 Bevel Back Weatherboard System Profiles 20/12/11

HC BEVEL 101 HC-BEVEL-101 Bevel Back Weatherboard System Profiles 20/12/11

HC BEVEL 200 HC-BEVEL-200 Window Head Detail, Aluminium Joinery 20/12/11

HC BEVEL 201 HC-BEVEL-201 Window Sill Detail, Aluminium Joinery 20/12/11

HC BEVEL 202 HC-BEVEL-202 Window Jamb Detail, Aluminium Joinery 20/12/11

HC BEVEL 210 HC-BEVEL-210 Door Head Detail Aluminium Joinery 20/12/11

HC BEVEL 211 HC-BEVEL-211 Door Sill Detail, Aluminium Joinery 20/12/11

HC BEVEL 212 HC-BEVEL-212 Door Jamb Detail, Aluminium Joinery 20/12/11

HC BEVEL 220 HC-BEVEL-220 Window Head Detail, Timber Joinery 20/12/11

HC BEVEL 221 HC-BEVEL-221 Window Sill Detail, Timber Joinery 20/12/11

HC BEVEL 222 HC-BEVEL-222 Window Jamb Detail, Timber Joinery 20/12/11

HC BEVEL 300 HC-BEVEL-300 Internal Corner HP110 20/12/11

HC BEVEL 301 HC-BEVEL-301 Internal Corner Scribed 20/12/11

HC BEVEL 302 HC-BEVEL-302 Internal Corner Boxed 20/12/11

HC BEVEL 400 HC-BEVEL-400 External Corner Boxed 20/12/11

HC BEVEL 401 HC-BEVEL-401 External Corner Soaker 20/12/11

HC BEVEL 410 HC-BEVEL-410 General Detail Cavity Fix, Stain Finish 20/12/11

HC BEVEL 411 HC-BEVEL-411 General Detail Cavity Fix, Paint Finish 20/12/11

HC BEVEL 500 HC-BEVEL-500 Base OF Wall, Concrete 20/12/11

HC BEVEL 501 HC-BEVEL-501 Base Of Wall, Timber 20/12/11

HC BEVEL 600 HC-BEVEL-600 Roof/Wall Junction 20/12/11

HC BEVEL 601 HC-BEVEL-601 Barge Detail, Overhang 20/12/11

HC BEVEL 602 HC-BEVEL-602 Eaves Detail, Overhang 20/12/11

HC BEVEL 603 HC-BEVEL-603 Eaves Detail, No Overhang 20/12/11

HC BEVEL 700 HC-BEVEL-700 Parapet Detail 20/12/11

HC BEVEL 800 HC-BEVEL-800 Meter Box Detail 20/12/11

HC BEVEL 801 HC-BEVEL-801 Pipe Penetration Detail 20/12/11

HC BEVEL 802 HC-BEVEL-802 Pipe Penetration Plan Detail 20/12/11

DRAFT

Copyright Herman Pacific

Page 2: Hermpac

140

18.5

18.5

18.5

18.5

18.5

18.5

18.5

220

190

140

190

190

- 108mm Cover

- 158mm Cover

- 165mm Cover

- 115mm Cover

- 115mm Cover

- 165mm Cover

- 195mm Cover

HP61 Bevel Back Weatherboard

HP62 Bevel Back Weatherboard

HP64 Rebated Bevel Back Weatherboard

HP63 Rebated Bevel Back Weatherboard

HP150 New Bevel Back

HP151 New Bevel Back

HP152 New Bevel Back

140

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

1 : 2 @ A4 20/12/11

HC-BEVEL-100Bevel Back Weatherboard System Profiles

DRAFT

Copyright Herman Pacific

Page 3: Hermpac

90

18

69

18

40

27

39

39

18.5

18.5

180

135

HP32 Eaves Moulding

HP110 Internal Corner Mould

HP202 Cover Batten HP201 Cover Batten

HP69 Grooved Fascia

HP70 Grooved Fascia

HP 11 Timber Scriber

HP 13 Timber Scriber

HP 12 Timber Scriber

40

60 40

17

17

10

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

1 : 2 @ A4 20/12/11

HC-BEVEL-101Bevel Back Weatherboard System Profiles

DRAFT

Copyright Herman Pacific

Page 4: Hermpac

Breather Type BuildingWrap

Continuous Sealant OverPEF Rod

co

ver

10 m

in.

Aluminium Head Flashingwith minimum 15 degree fall

& optional Hem Edges as

per Table 7 E2/AS1

Timber Packer

Selected AluminiumWindow Joinery

Flexible Flashing Tape Over

Internal Lining

Timber Framing

Timber Architrave

7 m

in.

HP62 Bevel BackWeatherboard

to F

lash

ing

35 m

in.

co

ver

Ceadar Weatherhead ifRequired

5 m

in. g

ap

20 min.

Head Flashing Turned up toform Stop End

Cavity Closure Strip with15mm drip edge to

cladding

Head Flashing Stop End

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-200Window Head Detail, Aluminium Joinery

DRAFT

Copyright Herman Pacific

Page 5: Hermpac

Breather Type BuildingWrap

Continuous Sealant OverPEF Rod

Timber Packer

Selected AluminiumWindow Joinery

Timber Window SupportPacker

Flexible Flashing Tapecontinuous along sill,

100mm min. up each jamb

and 50mm onto face of

underlay

Internal Lining

Timber Architrave

Timber Framing

8 min. cover to Joinery

Horizontal Batten underwindow as nessesary to suit

profile

Provide window support asrequired by window

manufacturer

HP62 Bevel BackWeatherboard

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-201Window Sill Detail, Aluminium Joinery

DRAFT

Copyright Herman Pacific

Page 6: Hermpac

Timber Packer

Breather Type BuildingWrap

Selected AluminiumWindow Joinery

Continuous Sealant OverPEF Rod

Flashing extension

20 min Head

10 min. cover

Line of Head Flashing Over

Flexible Flashing Tapecontinuous along sill,

100mm min. up each jamb

and 50mm onto face of

underlay

Timber Architrave

HP12 Scriber cut to suitprofile, fixed and sealed to

Weatherboards

Timber Framing

Selected Herman PacificBevel Back Weatherboard

Internal Lining

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-202Window Jamb Detail, Aluminium Joinery

DRAFT

Copyright Herman Pacific

Page 7: Hermpac

Breather Type BuildingWrap

Continuous Sealant OverPEF Rod

Aluminium Head Flashingwith minimum 15 degree fall

& optional Hem Edges as

per Table 7 E2/AS1

Timber Packer

Selected Aluminium DoorJoinery

Flexible Flashing Tape Over

Internal Lining

Timber Framing

HP62 Bevel BackWeatherboard

Ceadar Weatherhead ifRequired

5 m

in. g

ap

co

ver

10 m

in.

20 min.

Head Flashing Turned up toform Stop End

to F

lash

ing

35 m

in.

co

ver

Cavity Closure Strip with15mm drip edge to

cladding

Head Flashing Stop End

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-210Door Head Detail Aluminium Joinery

DRAFT

Copyright Herman Pacific

Page 8: Hermpac

Breather Type BuildingWrap

Continuous Sealant OverPEF Rod

Timber Packer

Timber Door SupportPacker

Flexible Flashing Tapecontinuous along sill,

100mm min. up each jamb

and 50mm onto face of

underlay

Internal Lining

Timber Architrave

Timber Framing

Horizontal Batten underwindow as nessesary to suit

profile

8 min. cover to Joinery

HP62 Bevel BackWeatherboard

Provide window support asrequired by window

manufacturer

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-211Door Sill Detail, Aluminium Joinery

DRAFT

Copyright Herman Pacific

Page 9: Hermpac

Timber Packer

Breather Type BuildingWrap

Selected Aluminium DoorJoinery

Continuous Sealant OverPEF Rod

Flashing extension

20 min Head

Line of Head Flashing Over

Flexible Flashing Tapecontinuous along sill,

100mm min. up each jamb

and 50mm onto face of

underlay

Timber Architrave

HP12 Scriber cut to suitprofile, fixed and sealed to

Weatherboards

Timber Framing

Selected Herman PacificBevel Back Weatherboard

Internal Lining

10 min. cover

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-212Door Jamb Detail, Aluminium Joinery

DRAFT

Copyright Herman Pacific

Page 10: Hermpac

Breather Type BuildingWrap

Continuous Sealant OverPEF Rod

Aluminium Head Flashingwith minimum 15 degree fall

& optional Hem Edges as

per Table 7 E2/AS1

Timber Packer

Flexible Flashing Tape Over

Internal Lining

Timber Framing

Timber Window Head toNZS 3610

10 min.cover

HP62 Bevel BackWeatherboard

Ceadar Weatherhead ifRequired

Cavibat Cavity Batten

Cavity Closure Strip with15mm drip edge to

cladding

Head Flashing Stop End

to F

lash

ing

35 m

in.

co

ver

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-220Window Head Detail, Timber Joinery

DRAFT

Copyright Herman Pacific

Page 11: Hermpac

Breather Type BuildingWrap

Timber Packer

Flexible Flashing Tapecontinuous along sill,

100mm min. up each jamb

and 50mm onto face of

underlay

HP62 Bevel BackWeatherboard

Internal Lining

Timber Sill Board

Timber Framing

Horizontal Batten underwindow as nessesary to suit

profile

150mm Deep Aluminium SillTray with 20mm Stop Ends

as per Table 7 E2/AS1

Timber Window Sill to NZS3610

to F

lashin

g

35 m

in.

co

ver

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-221Window Sill Detail, Timber Joinery

DRAFT

Copyright Herman Pacific

Page 12: Hermpac

Timber Packer

Breather Type BuildingWrap

Continuous Sealant OverPEF Rod

Flashing extension

20 min. Head

Line of Head Flashing Over

Flexible Flashing Tapecontinuous along sill,

100mm min. up each jamb

and 50mm onto face of

underlay

Timber Window Jamb toNZS 3610

HP202 Cover Batten

Internal Lining

Timber Framing

Line of Sill Flashing Under

Selected Herman PacificBevel Back Weatherboard

HP12 Scriber cut to suitprofile, fixed and sealed to

Weatherboards

H3.1 Timber Jamb Battensfinish clear of Sill Flashing

Cavibat Cavity Battens

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-222Window Jamb Detail, Timber Joinery

DRAFT

Copyright Herman Pacific

Page 13: Hermpac

75 x 75 Hermpac AluminiumInternal Corner Flashing.

Hem Edges option as per

E2 NZBC

HP110 Internal CornerMould

Flexible Flashing Tape

Breather Type BuildingWrap continuous around

corner

Timber Framing

Internal Lining

Selected Herman PacificBevel Back Weatherboard

Cavibat Cavity Battens

cover

30 min.

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-300Internal Corner HP110

DRAFT

Copyright Herman Pacific

Page 14: Hermpac

75 x 75 Hermpac AluminiumInternal Corner Flashing.

Hem Edges option as per

E2 NZBC

Flexible Flashing Tape

Breather Type BuildingWrap continuous around

corner

Timber Framing

Internal Lining

Selected Herman PacificBevel Back Weatherboard

notched and scribed at

corner

Cavibat Cavity Battens

cover

30 min.

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-301Internal Corner Scribed

DRAFT

Copyright Herman Pacific

Page 15: Hermpac

75 x 75 Hermpac AluminiumInternal Corner Flashing.

Hem Edges option as per

E2 NZBC

Flexible Flashing Tape

Breather Type BuildingWrap continuous around

corner

Timber Framing

Internal Lining

Selected Herman PacificBevel Back Weatherboard

HP12 Scriber cut to suitprofile, fixed and sealed to

Weatherboards

HP202 Cover Batten

HP201 Cover Batten

Cavibat Cavity Battens

30 m

in.

co

ver

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-302Internal Corner Boxed

DRAFT

Copyright Herman Pacific

Page 16: Hermpac

75 x 75 Hermpac AluminiumExternal Corner Flashing.

Hem Edges option as per

E2 NZBC

HP201 Cover Batten

HP202 Cover Batten

Breather Type BuildingWrap

Timber Framing

Internal Lining

Selected Herman PacificBevel Back Weatherboard

HP12 Scriber cut to suitprofile, fixed and sealed to

Weatherboards

Cavibat Cavity Battens

50 min cover

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-400External Corner Boxed

DRAFT

Copyright Herman Pacific

Page 17: Hermpac

75 x 75 Hermpac AluminiumExternal Corner Flashing.

Hem Edges option as per

E2 NZBC

Breather Type BuildingWrap

Timber Framing

Internal Lining

Selected Herman PacificBevel Back Weatherboard

mitred at corner

Corner Soaker

Cavibat Cavity Battens

cover

15 min.

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-401External Corner Soaker

DRAFT

Copyright Herman Pacific

Page 18: Hermpac

Internal Lining

85 x 3.25 HP Crown HeadAnnular Grooved Shank Nail

(or as per E2/AS1 - Table

24)

Timber Nogging asRequired

HP62 Bevel BackWeatherboard

32

mm

lap

Breather Type BuildingWrap

Cavibat Cavity Batten

35

- 40m

m

Internal Lining

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-410General Detail Cavity Fix, Stain Finish

DRAFT

Copyright Herman Pacific

Page 19: Hermpac

Internal Lining

85 x 3.25 HP Crown HeadStainless Steel Nail

punched, paint primed and

filled (or as per E2/AS1 -

Table 24)

Timber Nogging asRequired

HP62 Bevel BackWeatherboard

32

mm

lap

Breather Type BuildingWrap

Cavibat Cavity Batten

35

- 40m

m

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-411General Detail Cavity Fix, Paint Finish

DRAFT

Copyright Herman Pacific

Page 20: Hermpac

as p

er

Cla

use 9

.1.3

of

E2/A

S1

150 m

in. to

Perm

an

en

t P

avi

ng

or

225 m

in.

to U

np

ave

d G

rou

nd

Breather Type BuildingWrap

Timber Framing

Internal Lining

DPC

Concrete Slab

Finished Ground Level

6 mm Framing Overhang

HP62 Bevel BackWeatherboard

Flo

or

Leve

l

50 m

in. b

elo

w

Cavibat Cavity Batten

Cavity Closure Strip with15mm drip edge to

cladding

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-500Base OF Wall, Concrete

DRAFT

Copyright Herman Pacific

Page 21: Hermpac

Breather Type BuildingWrap

Timber Framing

Internal Lining

Timber Boundry Joist

Flo

or

Str

uctu

re

50 m

in b

elo

w

HP62 Bevel BackWeatherboard

Cavity Closure Strip with15mm drip edge to

cladding

Cavibat Cavity Batten

Floor Lining

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-501Base Of Wall, Timber

DRAFT

Copyright Herman Pacific

Page 22: Hermpac

5 m

ax.

Refer Fig. 7 & Table 7 of E2/AS1

130 or 200 min.

Fla

sh

ing

35 m

in. a

bo

ve

ab

ove

bo

tto

m o

f C

lad

din

g

75 m

in F

lashin

g L

eg

Flexible Flashing Tape Over

Timber Nogging asRequired

Breather Type BuildingWrap

Roof Flashing with BottomEdge Dressed Down or

Notched as per Table 7

E2/AS1

Roofing Underlay continuedup behind Flashing

Roof Framing

Selected roofing with StopEnd

HP62 Bevel BackWeatherboard

Cavity Closure Strip with15mm drip edge to

cladding

Cavibat Cavity Batten

15° min. slope

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-600Roof/Wall Junction

DRAFT

Copyright Herman Pacific

Page 23: Hermpac

see T

ab

le 7

of E

2/A

S1

50 t

o 9

0 m

in.

co

ver

Breather Type BuildingWrap

Timber Framing

HP32 Eaves Moulding

Soffit Lining

Selected Roofing

Barge Flashing as per Table7 E2/AS1

HP70 Grooved Fascia

Roofing Underlay continuedup behind Flashing

Timber Framing

HP62 Bevel BackWeatherboard

Cavibat Cavity Batten

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-601Barge Detail, Overhang

DRAFT

Copyright Herman Pacific

Page 24: Hermpac

Breather Type BuildingWrap

Timber Framing

HP32 Eaves Moulding

Soffit Lining

HP62 Bevel BackWeatherboard

Cavibat Cavity Batten

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-602Eaves Detail, Overhang

DRAFT

Copyright Herman Pacific

Page 25: Hermpac

Breather Type BuildingWrap

Timber Framing

Roof Framing

HP70 Grooved Fascia

Continuous Sealant

Timber Nogging asRequired

Barge Flashing with 10 mmhem as per Table 7 E2/AS1

Roofing Underlay

Selected roofing

Timber Purlin

Refer to Figure 45 of E2\AS1

125 min. Flashing cover

Selected Gutter

HP62 Bevel BackWeatherboard

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-603Eaves Detail, No Overhang

DRAFT

Copyright Herman Pacific

Page 26: Hermpac

H3.2 Treated Timber, or H39mm Plywood, or

Polystyrene Packer to form

slope. Refer Figure 10

E2/AS1 for details

Timber Packer

Cap Flashing with minimum5 Degree Fall & minimum

cover as per E2/AS1 Table

7. Fix through sides only

Roof Underlay to provideseperation of metal capping

and timber

HP62 Bevel BackWeatherboard

Cavibat Cavity Batten

Breather Type BuildingWrap

5° min. slope

min

imu

m r

eq

uired

co

ver

Refe

r Ta

ble

7 E

2/A

S1 f

or

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-700Parapet Detail

DRAFT

Copyright Herman Pacific

Page 27: Hermpac

Timber Nogging asRequired

Flexible Flashing Tapecontinuous along sill,

100mm min. up each jamb

and 50mm onto face of

underlay

Breather Type BuildingWrap

Continuous Sealant OverPEF Rod

Meter Box

Internal Lining

Continuous Sealant OverPEF Rod

Aluminium Head Flashingwith 15 degree slope as per

E2/AS1

Flexible Flashing Tape Over

5 m

in. g

ap

HP62 Bevel BackWeatherboard

Cavibat Cavity Batten

Cavity Closure Strip with15mm drip edge to

cladding

co

ver

10 m

in.

HP62 Bevel BackWeatherboard

Horizontal Batten underMeterbox as nessesary to

suit profile

Metal Angle sealed andriveted around edge of

Meter Box. Refer to Figure

69 E2/AS1

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-800Meter Box Detail

DRAFT

Copyright Herman Pacific

Page 28: Hermpac

Breather Type BuildingWrap

Internal Lining

HP62 Bevel BackWeatherboard

Flexible Flashing Tape Over

Rubber Pipe Boot withadhesive colar, fixed to

building wrap and sealed

to pipe. Refer to Figure 68

E2/AS1 for alternative

methods

Continuous Sealant

Support Pipe with Nogunder & a screw fixed strap

over

Pipe

Cavibat Cavity Batten

Cavity Closure Strip with15mm drip edge to

cladding

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-801Pipe Penetration Detail

DRAFT

Copyright Herman Pacific

Page 29: Hermpac

Rubber Pipe Boot withadhesive colar, fixed to

building wrap and sealed

to pipe. Refer to Figure 68

E2/AS1 for alternative

methods

Support Pipe with Nogunder & a screw fixed strap

over

Breather Type BuildingWrap

Flexible Flashing Tape Over

Continuous Sealant

Continuous Sealant

Internal Lining

Timber Framing

Pipe

Selected Herman PacificBevel Back Weatherboard

Cavibat Cavity Battens

SCALE ISSUED DATE

DRAWING

www.hermpac.co.nzSUBJECT TO CHANGE WITHOUT NOTICE

Cavity Fix Bevel Back Weatherboard System

Notes:- All nail fixings pre-drilled minimum 1mm diameter smaller thanthe nail gauge.- All products to be precoated & cut edges to be sealed as perBranz Bulletin 411.- All materials and fixtures are to comply with E2/AS1 Clause 2.2- Provide PVC bond break between H3.1 battens and any flashing

1 : 2 @ A4 20/12/11

HC-BEVEL-802Pipe Penetration Plan Detail

DRAFT

Copyright Herman Pacific