14
Hensel Integra Pro 500 Plus Strobe Unit Instructions Precautions Read First Before Setting Up Any Lights This compact flash unit is for indoor use only. Never use outside. The glass dome must be installed for the safe operation of each strobe. Halogen lights and flashtubes generate high pressure during operation and can explode, particularly if the kit is chilled in winter during transport. Ventilation slots of each flash unit must be kept clear of any obstruction to avoid over heating. Do not disconnect any cords while the unit is powered up. Never move a flash unit while it is operating. Always turn the flash off for any adjustments. Do not run cables long distances where they could be damaged from dollies, ladders or furniture. Do not expose any flash unit to humidity or water. Do not connect any accessories from any other manufacturer, even if they use the same or similar connectors. Eye damage may occur if the flash unit is set up less than 5 meters from your subject. Ventilate any closed rooms regularly to prevent a build-up of inadmissible ozone concentrations which may occur during operation. Reflectors, speedrings and other accessories heat up during long operations. To avoid injuries, handle with gloves or wait until parts have cooled to make any adjustments. Never over tighten any fittings. Always finger tight any knobs. Page 1

Upload: others

Post on 08-Aug-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Hensel Integra Pro 500 Plus Strobe Unit Instructionsblogs.eciad.ca/photo/files/2011/07/henselstrobe...strobe. 6. Install the metal shade or softbox (additional instructions included)

Hensel Integra Pro 500 Plus Strobe Unit Instructions

Precautions

Read First Before Setting Up Any Lights

This compact flash unit is for indoor use only. Never use outside.

The glass dome must be installed for the safe operation of each strobe. Halogen lights and flashtubes generate high pressure during operation and can explode, particularly if the kit is chilled in winter during transport.

Ventilation slots of each flash unit must be kept clear of any obstruction to avoid over heating.

Do not disconnect any cords while the unit is powered up.

Never move a flash unit while it is operating. Always turn the flash off for any adjustments.

Do not run cables long distances where they could be damaged from dollies, ladders or furniture.

Do not expose any flash unit to humidity or water.

Do not connect any accessories from any other manufacturer, even if they use the same or similar connectors.

Eye damage may occur if the flash unit is set up less than 5 meters from your subject.

Ventilate any closed rooms regularly to prevent a build-up of inadmissible ozone concentrations which may occur during operation.

Reflectors, speedrings and other accessories heat up during long operations. To avoid injuries, handle with gloves or wait until parts have cooled to make any adjustments.

Never over tighten any fittings. Always finger tight any knobs.

Page 1

Page 2: Hensel Integra Pro 500 Plus Strobe Unit Instructionsblogs.eciad.ca/photo/files/2011/07/henselstrobe...strobe. 6. Install the metal shade or softbox (additional instructions included)

Assembly Instructions

1. Plan out what you will need for your setup. Do not setup any unnecessary equipment. Keep It Simple!

2.

Page 2

Page 3: Hensel Integra Pro 500 Plus Strobe Unit Instructionsblogs.eciad.ca/photo/files/2011/07/henselstrobe...strobe. 6. Install the metal shade or softbox (additional instructions included)

Carefully remove the light stands from the bottom side compartment of the bag and spread out the base struts horizontally for maximum footprint and stability.

NOTE: Carefully lift the entire case for easy removal of the stands.

**Extremely Important**

3. Place a sandbag over each leg of the stand to prevent it from falling over.

NOTE: Sandbags are available for your use. See a Technician or Monitor on duty to sign out a few.

Page 3

Page 4: Hensel Integra Pro 500 Plus Strobe Unit Instructionsblogs.eciad.ca/photo/files/2011/07/henselstrobe...strobe. 6. Install the metal shade or softbox (additional instructions included)

4. Fasten each strobe head securely to the stand. Do not over tighten. Use finger tight pressure on any knobs.

Page 4

Page 5: Hensel Integra Pro 500 Plus Strobe Unit Instructionsblogs.eciad.ca/photo/files/2011/07/henselstrobe...strobe. 6. Install the metal shade or softbox (additional instructions included)

5. Remove the protective plastic cap by swinging the lever at the top of each strobe.

6. Install the metal shade or softbox (additional instructions included) by swinging the lever at the top of each strobe.

Page 5

Page 6: Hensel Integra Pro 500 Plus Strobe Unit Instructionsblogs.eciad.ca/photo/files/2011/07/henselstrobe...strobe. 6. Install the metal shade or softbox (additional instructions included)

7. Make any adjustments to the strobe and/or setup it up in the appropriate location before turning on.

8. Plug in each strobe and turn it on. Wait a minute for the fan to work fully.

Overview of Controls

Compact Flash Unit –

Controls Front Panel

Compact Flash Unit –

Controls Front Panel1. ON Main Switch

ON/OFF2. RC Remote Control

Switch & ON Indicator

3. AUDIO Acoustical Ready Signal & ON Indicator

4. FC Flash Check Switch & ON Indicator

5. SLAVE Slave Switch & ON Indicator

6. TEST Manual Flash Release with Ready Indicator

7. Sync Socket

8. Slave

9.

Fuse 2A

10. 115V/60 Hz Main Connector

11. FULL Modeling Lamp Operation Mode & ON Indicator

Page 6

Page 7: Hensel Integra Pro 500 Plus Strobe Unit Instructionsblogs.eciad.ca/photo/files/2011/07/henselstrobe...strobe. 6. Install the metal shade or softbox (additional instructions included)

12. PROP Modeling Lamp Operation Mode & ON Indicator

13. Flash Power Control SwitchPress For Channel Selection

14. LED Display

RC = Remote Control SwitchThe head can become a radio control for slave purposes. Select when using the flash wizard.

AUDIO Always leave this on

FC = Flash Check SwitchAfter taking a photograph, the modeling lights come back on after 5 seconds when the flash is recharged and ready for another shot.

SLAVE The built in slave can trigger other flash units in this kit.

Please keep additional flash units at least 2 meters apart or the built in slave may be damaged. Deselect SLAVE and use a cable if it is not possible to have the units setup farther apart.

TEST Test the flash by pressing the button.

FULL Gives the full amount of power to the modeling lights.

PROP Shows the amount of modeling light intensity selected for the flash unit according to the LED number. (in the example; 6.4) The intensity of the modeling light is adjusted to match the amount of light the flash will give off.

Tilting Head ComponentsTilting Head Components

Page 7

Page 8: Hensel Integra Pro 500 Plus Strobe Unit Instructionsblogs.eciad.ca/photo/files/2011/07/henselstrobe...strobe. 6. Install the metal shade or softbox (additional instructions included)

15. Cable Holder16. Pre-Fiction17. Tilting Head Shift to Balance Heavy Loads18. Clamping Screw for Umbrella Attachment19. Locking Screw for Head Attachment to Stand20. Wing Nut for Head Angle Adjustment

Umbrella Installation

1. Always use a metal shade in combination with an umbrella.

2. Firmly insert the stem of the umbrella into the clamping screw of the tilting head.

3. Adjust the distance of the umbrella to the strobe. The goal is to have the strobe’s ring of

light reflected in the umbrella without spilling out the sides of the umbrella.

Page 8

Page 9: Hensel Integra Pro 500 Plus Strobe Unit Instructionsblogs.eciad.ca/photo/files/2011/07/henselstrobe...strobe. 6. Install the metal shade or softbox (additional instructions included)

Radio Transmitter ControlsRadio Transmitter Controls

21a. Flash Power Down and Modeling Light Options21b. Flash Power Up22. Channel Selection for 3 Channels23. Test Button for Flash24. Socket for Included Sync Cable 25. Hot Shoe Mounting to Camera26. Battery CompartmentRadio Receiver ControlsRadio Receiver Controls

27. Channel Selector for 3 Channels

Page 9

Page 10: Hensel Integra Pro 500 Plus Strobe Unit Instructionsblogs.eciad.ca/photo/files/2011/07/henselstrobe...strobe. 6. Install the metal shade or softbox (additional instructions included)

28. LED Green when Sync Voltage is Applied29. LED Red when Low Battery30. Interface Socket31. Battery Compartment

Slave Options

There are 3 possible ways the Hensel Strobe Unit can be slaved to each other:

1. SLAVE button on the back of the head.

Select the SLAVE button on each head that requires slaving.Keep flash units at least 2 meters apart or the built-in slave may be damaged. Deselect SLAVE and use a flash sync cable if it is not possible to have the units setup farther apart.

2. Hensel Strobe Wizard Plus

Insert wizard into camera’s flash mount and connect wire into the sync port of the camera.Each strobe can be setup for independent control from the wizard using the channel option located on the side of the wizard. On the strobe head press the Flash Power Control Switch for channel selection.

Page 10

Page 11: Hensel Integra Pro 500 Plus Strobe Unit Instructionsblogs.eciad.ca/photo/files/2011/07/henselstrobe...strobe. 6. Install the metal shade or softbox (additional instructions included)

Page 11

Page 12: Hensel Integra Pro 500 Plus Strobe Unit Instructionsblogs.eciad.ca/photo/files/2011/07/henselstrobe...strobe. 6. Install the metal shade or softbox (additional instructions included)

Radio Transmitter ControlsRadio Transmitter Controls

21a. Flash Power Down and Modeling Light Options21b. Flash Power Up22. Channel Selection for 3 Channels23. Test Button for Flash24. Socket for Included Sync Cable 25. Hot Shoe Mounting to Camera26. Battery Compartment

3. Sync Socket at the Top of Each Strobe

A cable is

provided in the kit for direct connection to your camera from a strobe.

Page 12

Page 13: Hensel Integra Pro 500 Plus Strobe Unit Instructionsblogs.eciad.ca/photo/files/2011/07/henselstrobe...strobe. 6. Install the metal shade or softbox (additional instructions included)

Honeycomb Diffuser Installation

1. Insert the honeycomb ring into the large metal shade with the white tab pointing up for easy removal. Carefully secure to strobe head.

Softbox Installation

1. Carefully follow the step-by-step instructions for assembly.

Page 13

Page 14: Hensel Integra Pro 500 Plus Strobe Unit Instructionsblogs.eciad.ca/photo/files/2011/07/henselstrobe...strobe. 6. Install the metal shade or softbox (additional instructions included)

2. The metal rods are under tension and care should be taken in their assembly and disassembly.

3. The metal shade is not required for the Softbox installation.

4. Slide the assembled Softbox carefully over the glass dome and swing the lever at the top of the head over to secure the Softbox to the head.

Page 14