hen design.pdf

40
DESIGN OF MAXIMUM ENERGY RECOVERY  NETWORKS

Upload: tuansyafiq

Post on 14-Apr-2018

306 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 1/40

DESIGN OF MAXIMUMENERGY RECOVERY

 NETWORKS

Page 2: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 2/40

MER NETWORKS

• Networks featuring minimum utility usageare called MAXIMUM ENERGY

RECOVERY (MER) Networks.

Page 3: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 3/40

DIVISION AT THE PINCH

RECALL THAT

• No heat is transferred through the pinch.

• This makes the region above the pinch a

HEAT SINK region and the region belowthe pinch a HEAT SOURCE region.

Page 4: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 4/40

Pinch

Minimum

heating utility

Minimum

cooling utilityHeat Source

Heat is released to

cooling utility

Heat Sink 

Heat is obtained from

the heating utility

7.5

12.0

14.0

0.0

-6.0

1.0

-4.0

4.0

3.0

9.0

-2.0

-2.0

14.0

1.5

10.0

T

H

Page 5: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 5/40

CONCLUSION

• One can analyze the two systems separately,

that is,

• Heat exchangers will not contain heattransfer across the pinch.

Page 6: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 6/40

PINCH MATCHES• Consider two streams above the pinch

Q/FCpH > Q/FCpC

T p- ∆TminTC,outQ

TH,inT p

TC,out= T p- ∆Tmin + Q/FCpC

TH,in= T p+Q/FCpH

But TH,in> TC,out+ ∆Tmin.

Thus replacing one obtains

FCpH <FCpCGolden rule for pinch

matches above the pinch.

∆Tmin Violation when FCpH >FCpC∆Tmin

Page 7: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 7/40

EXERCISE

• A similar rule is obtained below the pinch. Derive it

and illustrate it.

Page 8: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 8/40

ANSWER TH,out

T p- ∆Tmin

TC,inQ

T p

TC,in= T p- ∆Tmin - Q/FCpC

TH,out= T p-Q/FCpH

But TH,out> TC,in + ∆Tmin.

Thus replacing one obtains

FCpC <FCpHGolden rule for pinchmatches below the pinch.

∆Tmin∆Tmin

Violation when FCpC >FCpH

Page 9: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 9/40

CONCLUSION

• Since matches at the pinch need to satisfy these rules,one should start locating these matches first. Thus, our first design rule:

START BY MAKING PINCH

MATCHES

Page 10: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 10/40

QUESTION

• Once a match has been selected how much heat should be exchanged?

Page 11: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 11/40

ANSWER • As much as possible!

• This means that one of the streams has its dutysatisfied!!

THIS IS CALLLED THE

TICK-OFF RULE

Page 12: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 12/40

HANDS ON EXERCISE

Stream Type Supply T Target T ∆H F*Cp

(oC) (oC) (MW) (MW oC-1)

Reactor 1 feed Cold 20 180 32.0 0.2

Reactor 1 product Hot 250 40 -31.5 0.15

Reactor 2 feed Cold 140 230 27.0 0.3

Reactor 1 product Hot 200 80 -30.0 0.25

T=140 0C

T=20 0C

∆H=27 MW

REACTOR 2

∆H=-30 MW

∆H=32 MW

REACTOR 1

∆H=-31.5 MW

T=230 0C

T=180 0CT=250 0C T=40 0C

T=200 0CT=80 0C

∆Tmin=10 oC PINCH=150 oC

Page 13: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 13/40

HANDS ON EXERCISE

Stream Type Supply T Target T ∆H F*Cp

(oC) (oC) (MW) (MW oC-1)

Reactor 1 feed Cold 20 180 32.0 0.2

Reactor 1 product Hot 250 40 -31.5 0.15

Reactor 2 feed Cold 140 230 27.0 0.3

Reactor 1 product Hot 200 80 -30.0 0.25

∆Tmin=10 oC PINCH=150 oC

200 0C

20 0C

40 0C

180 0C

250 0CH1

H2

C2

C1

230 0C

FCp=0.15

FCp=0.25

FCp=0.2

FCp=0.3

140 0C

80 0C

150 0C

Page 14: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 14/40

ABOVE THE PINCH

• Which matches are possible?

200 0C

180 0C

250 0CH1

H2

C2

C1

230 0C

FCp=0.15

FCp=0.25

FCp=0.2

FCp=0.3

140 0C

150 0C

Page 15: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 15/40

ANSWER (above the pinch)

2000

C

180 0C

250 0CH1

H2

C2

C1

230 0C

FCp=0.15

FCp=0.25

FCp=0.2

FCp=0.3140 0C

150 0C

• The rule is that FCpH <FCpC . We therefore can onlymake the match H1-C1 and H2-C2.

Page 16: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 16/40

ANSWER (above the pinch)

• The tick-off rule says that a maximum of 8 MW is exchangedin the match H1-C1 and as a result stream C1 reaches its targettemperature.

• Similarly 12.5 MW are exchanged in the other match and thestream H2 reaches the pinch temperature.

200 0C

180 0C

203.3 0CH1

H2

C2

C1

181.7 0C

FCp=0.15

FCp=0.25

FCp=0.2

FCp=0.3

140 0C

150 0C

8

12.5

230 0C

250 0C

Page 17: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 17/40

BELOW THE PINCH

• Which matches are possible?

20 0C

40 0CH

1

H2

C1

FCp=0.15

FCp=0.25

FCp=0.2 140 0C

80 0C

150 0C

The rule is that FCpC <FCp H . Thus, we can

only make the match H2-C1

Page 18: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 18/40

ANSWER (below the pinch)

• The tick-off rule says that a maximum of 17.5 MW isexchanged in the match H2-C1 and as a result stream H2reaches its target temperature.

52.5 0C

40 0CH1

H2

C1

FCp=0.15

FCp=0.25

FCp=0.2 140 0C

80 0C

150 0C

17.5

20 0C

Page 19: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 19/40

COMPLETE NETWORK AFTER PINCH MATCHES

• Streams with unfulfilled targets are colored.

200 0C

180 0C

203.3 0CH1

H2

C2

181.7 0C

FCp=0.15

FCp=0.25

FCp=0.2

FCp=0.3

140 0C

8

12.5

52.5 0C C1

140 0C

80 0C

150 0C

17.5

250 0C

230 0C

20 0C

40 0C

Page 20: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 20/40

WHAT TO DO NEXT?

• Away from the pinch, there is more flexibility to make

matches, so the inequalities do not have to hold.

• The pinch design method leaves you now on your own!!!!!

• Therefore, use your judgment as of what matches to select!!

2000

C

180 0C

203.3 0CH1

H2

C2

181.7 0C

FCp=0.15

FCp=0.25

FCp=0.2

FCp=0.3

140 0C

8

12.5

52.5 0C C1

140 0C

800

C

150 0C

17.5

250 0C

230 0C

20 0C

40 0C

Page 21: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 21/40

ANSWER 

• We first note that we will use heating above the pinch. Thusall hot streams need to reach their inlet temperature. We are

then forced to look for a match for H1. Please locate it.

200 0C

180 0C

203.3 0CH

1

H2

C2

181.7 0C

FCp=0.15

FCp=0.25

FCp=0.2

FCp=0.3

140 0C

8

12.5

52.5 0C C1

140 0C

80 0C

150 0C

17.5

250 0C

230 0C

20 0C

40 0C

Page 22: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 22/40

ANSWER 

140 0C

• The match is H1-C1. We finally put a heater on the

cold stream

200 0C

180 0C

H1

H2

C2

230 0C

FCp=0.15

FCp=0.25

FCp=0.2

FCp=0.38

12.5

52.5 0C C1

140 0C

80 0C

150 0C

17.5

77.5

H

250 0C

200

C

40 0C

Page 23: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 23/40

ANSWER • Below the pinch we try to have the cold streams start at

their inlet temperatures and we later locate coolers (one in

this case).

140 0C

200 0C

180 0C

H1

H2

C2

230 0C

FCp=0.15

FCp=0.25

FCp=0.2

FCp=0.38

12.5

20 0C C1

140 0C

80 0C

150 0C

17.5

77.5

H6.5

C

10

40 0C250 0C

Page 24: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 24/40

DISCUSSION

• State what are your objections to the pinch design

method, so far!!

Page 25: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 25/40

THESE ARE MINE

• It seems to imply building expertise• It does not seem to guarantee that one will always

obtain a good result.

• What if there are unequal number of streams at the pinch?

• What if the inequalities are not satisfied at the

 pinch?

Page 26: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 26/40

GENERAL FORMULA FOR UNIT TARGETING

Nmin= (S-P)above pinch+ (S-P) below pinch

If we do not consider two separate problems, above

and below the pinch we can get misleading results.

Page 27: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 27/40

EXAMPLE

Nmin= (S-P)above pinch+ (S-P) below pinch =

=(5-1) + (4-1) = 7

If we do not consider two separate problems

 Nmin= (6-1)= 5, which is wrong

Note: A heat exchanger network with 5 exchangers exists, but it is impractical andcostly. This is beyond the scope of this course.

140 0C

200 0C

180 0C

H1

H2

C2

230 0C

FCp=0.15

FCp=0.25

FCp=0.2

FCp=0.38

12.5

20 0C C1

140 0C

80 0C

150 0C

17.5

77.5

H6.5

C

10

250 0C 40 0C

Page 28: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 28/40

UNEQUAL NUMBER OFSTREAMS AT THE PINCH

Above the pinch, we notice the following rule

SH≤SC

Page 29: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 29/40

UNEQUAL NUMBER OF

STREAMS AT THE PINCH

Indeed, if the number of hot streams is larger than the

number of cold streams, then no pinch matches are possible.

C2

C1

H1

H2

H3

Assume the matches H1-C1 and

the matches H2-C2 have beenselected. Since H3 needs to go to

the pinch temperature, there is no

cold stream left to match, even if 

there is portions of C1 or C2 that

are left for matching. Suchmatching would be infeasible.

150 OC 100 OCFCp=0.15

FCp=0.25

FCp=0.2

FCp=0.4

FCp=0.1

90 OC

7.5

140 OC

10

Target=170 OC127.5 OC

122.5 OCTarget=140 OC

130 OC

What is then, the solution?

Page 30: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 30/40

ANSWER 

Split cold stream until the inequality is satisfied.

Notice that different combinations of flowrates in the split

satisfy the inequality.

C2

C1

H1

H2

H3

150O

C100 OC

FCp=0.15

FCp=0.25

FCp=0.2

FCp=0.25

FCp=0.1

90 OC

7.5

140 OC

10

Target=170 OC127.5 OC

130 OCTarget=140 OC

130 OC

FCp=0.15 110 OC

3

Page 31: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 31/40

UNEQUAL NUMBER OFSTREAMS AT THE PINCH

A similar rule can be discussed below the pinch,

that is,

SH≥SC

and similar splitting of hot streams may benecessary.

Page 32: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 32/40

INEQUALITY NOTSATISFIED

Consider the following case:

C2

C1

H1

150 OC 100 OCFCp=0.5

FCp=0.2

FCp=0.4

90 OCTarget=170 OC

Target=140 OC

Suggest a solution.

Page 33: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 33/40

ANSWER Split the hot stream

C2

C1

H1 150O

C 100O

CFCp=0.2

FCp=0.2

FCp=0.4

90 OC

15

Target=170 OC

Target=140 OC

FCp=0.3

10

140 OC

127.5 OC

Page 34: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 34/40

SOLVE THE FOLLOWING

PROBLEM

Below the Pinch :

C1

H2

H1

100 OCFCp=0.5

FCp=0.3

FCp=0.790 OC

Target=40 OC

Target=20 OC

30 OC

Page 35: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 35/40

ANSWER 

Below the Pinch :

30

C1

H2

H1

100 OCFCp=0.5

FCp=0.3

FCp=0.590 OC

Target=40 OC

Target=20 OC

30 OC

FCp=0.2

12

40 OC

60 OC

Page 36: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 36/40

COMPLETE PROCEDUREABOVE THE PINCH

Start

SH≤SC

Split Cold

Stream

FCpH≤FCpC

at pinch?

Place

matchesSplit Hot

Stream

YesYes

NoNo

Page 37: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 37/40

COMPLETE PROCEDUREBELOW THE PINCH

SH≥SC

Split Hot

Stream

FCpH≥ FCpC

at pinch?

Split Cold

Stream

Start

Place

matches

YesYes

No No

Page 38: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 38/40

HANDS ON EXERCISEType Supply T Target T F*Cp

(oC) (oC) (MW oC-1)

Hot 750 350 0.045

Hot 550 250 0.04

Cold 300 900 0.043

Cold 200 550 0.02

∆Tmin=50 oC

Minimum Heating Utility= 9.2 MW

Minimum Cooling Utility= 6.4 MW

Page 39: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 39/40

ANSWER 

750 0C

900 0C

H1

H2

C2

FCp=0.045

FCp=0.04

FCp=0.043

FCp=0.02

500 0C

8

C1

250 0C

61

9.2

300 0C

8.6

0.4

550 0C

550 0C

6

3500

C

200 0C

FCp=0.04

686.05 0C 400 0C

358.89 0C

Page 40: HEN Design.pdf

7/27/2019 HEN Design.pdf

http://slidepdf.com/reader/full/hen-designpdf 40/40

ANSWER 