heating pl 2015 cze - daikin hce program€¦ · daikin inverter compressors with high modulation...
TRANSCRIPT
2
> Daikin Altherma low temperature split
System Introduction 4
Technical Specifications 6
Pricelist 8
> Daikin Altherma low temperature monobloc
System Introduction 10
Technical Specifications 12
Pricelist 14
> Daikin Altherma high temperature
System Introduction 16
Technical Specifications 18
Pricelist 20
> Daikin Altherma hybrid heat pump
System Introduction 22
Technical Specifications 24
Pricelist 25
Flue Gas System 26
> Daikin Altherma ground source heat pump
System Introduction 28
Technical Specifications 30
Pricelist 31
> Daikin Altherma Flex Type
System Introduction 32
Technical Specifications 34
Pricelist 36
> Daikin heat pump convector
System Introduction 38
Technical Specifications 39
Pricelist 39
> Daikin solar system
System Introduction 40
Technical Specifications 42
Pricelist 43
> Table of contents
▪ NOTESThe pricelist is valid from 15. April 2015. All prior pricelists are not valid anymore. All prices are list prices in Euro and excl. VAT. The Daikin Commercial Terms
and Conditions apply (see last page or http://www.daikin-ce.com). We reserve the right for printing errors and model changes.
NEW!
3
You and your customer have decided to switch to an energy-effi cient heating
system that produces low CO2 emissions. Daikin Altherma is a total heating
and domestic hot water system based on air source heat pump technology.
One that represents a fl exible and cost-eff ective alternative to a fossil fuel boiler.
It also has an option for cooling.*
The inherent energy-effi ciency characteristics of Daikin Altherma make it
an ideal solution for reduced energy consumption and low CO2
emissions. Its high- and low-temperature heating systems provide optimal
comfort. Highly energy-effi cient heat pumps with advanced compressor
technology transform unused and inexhaustible heat from the surrounding air
into usable heat, either as part of the overall climate-control system or to
heat domestic hot water. Moreover, the system is easy to install.
*The Daikin Altherma cooling option is available for low-temperature heating systems (under fl oor heating system, heat pump convectors).
4
High heat pump effi ciencies at all outdoor and water
temperatures guarantee low running costs and low CO2
emissions.
High heating capacities enable best effi ciencies down to low
outside temperature. The electrical back-up heater assistance is
no longer required or only very limited.
Daikin inverter compressors with high modulation range
provide:
– Higher compressor effi ciency in partial load operation.
– Delivered capacities exactly matching the actual heating
demand of the building.
– Obtaining the capacities needed with minimum energy
consumption.
– Less on/off operation, increasing the operation life cycle
of the compressor.
Limiting electrical inputs of auxiliary components
contribute to the high seasonal effi ciencies:
– Factory-mounted high effi ciency circulating pump
already qualifying for future regulations (ErP2015) with
an A-energy label (EEI ≤ 0.23)
– No standby losses of inverter drive PCB, lowering
electricity consumption during standby mode
– No bottom plate heater needed on 4-8kW class
– Low-capacity bottom plate heater on 11-16kW class
(ERLQ-C series), only operating during defrost cycles.
NEW: Optimised unit for low heat loads available
The new-build house market in Europe is moving towards
smaller heat loads, due to:
– Growing importance of low-energy houses
– Strengthened legislation on energy consumption in
new residential constructions (e.g. EPBD regulations)
– Decreasing size of new-build houses
– EU member states planning to reach their
20-20-20 targets
The new Daikin Altherma low temperature is designed to
meet the requirements of newly built and low-energy houses
characterised by low heat loads.
With capacities from 4 to 16kW Daikin Altherma covers 90%
of all new built applications.
All types of heat emitters are possible:
– Under-fl oor heating: 25°C à 35°C
– Heat pump convector: 35°C à 45°C
– Low temperature radiators: 40°C à 50°C
Daikin Altherma is suitable for all climates, even
withstanding severe winter conditions.
Best seasonal effi ciencies,providing the highest savings on
running costs and CO2 emissions.
Perfect fi t
for new builds,
as well as for low-energy houses
> Daikin Altherma low temperature split
COP up to 4,02
A2/W35 (according to
EN14511)
5
Easiest and fastest installation, domestic hot water tank included
– Fast installation: the stainless steel domestic hot water
tank is included in the unit, with all connections between
heat pump module and tank factory made.
– All hydraulic components are included.
– Lower installation footprint.
Minimised installation space, both in terms of footprint
and height:
– Small footprint with a width
of only 60cm and a depth of 74cm
– The required installation height is
less than 2m
– Sleek design and modern look
Best solution for domestic hot water
heating with high effi ciency and high comfort
– 50% less heat loss compared to a standard insulated tank.
– High hot water volumes: 300l at 40°C, enough for
6 showers without any electrical assistance.
Wall-mounted indoor unit including all hydraulic components.
Quick and easy commissioning:
– Quick confi guration wizard to guide installer through
commissioning process
– Menu-based navigation to fi ne-tune the basic parameters
– Parameters are up- and downloadable from/to PC
– Actuator test mode to activate all wired components
one by one
– Automatic screed-drying function
Room temperature control functionality:
The user interface itself is equipped with a temperature sensor
and can be directly used as a rom thermostat, resulting in more
stable room temperatures, increased effi ciency and operation
life cycle.
User-friendly with intuitive control:
– The large graphical interface allows an intuitive and
self-explanatory menu
– Provides additional information such as the energy
consumption and heat production of the system
74
cm
60 cm
Graphical screen with backlight
On/Off
Menu back
Navigational buttonsConfi rm
Home
Error info
Integratedindoor unit: best solution for domestic
hot water for installer & customer
User interface:
high functionalities, easy to use
> Daikin Altherma low temperature split
6
HEATING & COOLING
INDOOR UNIT - WALL MOUNTEDEHBX04CB3V
EHBX08CB3VEHBX08CB9W
Dimensions Unit H x W x D mm 890x480x344 890x480x344
Operation range Heating Water side Min.~Max. °C 15~55 15~55
Cooling Water side Min.~Max. °C 5~22 5~22
Domestic hot water Water side Min.~Max. °C 25~80 25~80
Sound pressure level* Nom. dBA 26 26
Power supply (phase/voltage) 1~/230V 1~/230V / 3~/400V
HEATING ONLY
INDOOR UNIT - FLOORSTANDINGEHVH04S18CB3V
EHVH08S18CB3VEHVH08S26CB9W
Dimensions Unit H x W x D mm 1.732x600x728 1.732x600x728
Operation range Heating Water side Min.~Max. °C 15~55 15~55
Domestic hot water Water side Min.~Max. °C 25~60 25~60
Sound pressure level* Nom. dBA 28 28
Power supply (phase/voltage) 1~/230V 1~/230V / 3~/400V
HEATING & COOLING
INDOOR UNIT - FLOORSTANDINGEHVX04S18CB3V
EHVX08S18CB3VEHVX08S26CB9W
Dimensions Unit H x W x D mm 1.732x600x728 1.732x600x728
Operation range Heating Water side Min.~Max. °C 15~55 15~55
Cooling Water side Min.~Max. °C 5~22 5~22
Domestic hot water Water side Min.~Max. °C 25~60 25~60
Sound pressure level* Nom. dBA 28 28
Power supply (phase/voltage) 1~/230V 1~/230V / 3~/400V
OUTDOOR UNIT ERLQ004CV3 ERLQ006CV3 ERLQ008CV3
Heating capacity Min. kW 1,80 1 1,801 1,801
Nom. kW 4,401 / 3,272 6,001 / 4,582 7,401 / 5,802
Max. kW 5,121 8,351 10,021
Cooling capacity Nom. kW 5,003 / 4,174 6,763 / 4,844 6,863 / 5,364
COP nom. 5,041 / 4,022 4,741 / 3,682 4,451 / 3,532
EER nom. 3,373 / 2,324 3,453 / 2,344 3,423 / 2,294
Dimensions Unit H x W x D mm 735x832x307 735x832x307 735x832x307
Operation range Heating Min.~Max. °C -25~25 -25~25 -25~25
Cooling Min.~Max. °C 10~43 10~43 10~43
Domestic hot water Min.~Max. °C -25~35 -25~35 -25~35
Sound pressure
level*
Heating Nom. dBA 48 48 49
Cooling Nom. dBA 48 49 50
Power supply (phase/voltage) 1~/230V 1~/230V 1~/230V
▪ Technical specifi cations
> Daikin Altherma low temperature split
INDOOR UNIT - WALL MOUNTEDEHBH04CB3V
EHBH08CB3VEHBH08CB9W
Dimensions Unit H x W x D mm 890x480x344 890x480x344
Operation range Heating Water side Min.~Max. °C 15~55 15~55
Domestic hot water Water side Min.~Max. °C 25~80 25~80
Sound pressure level* Nom. dBA 26 26
Power supply (phase/voltage) 1~/230V 1~/230V / 3~/400V
HEATING ONLY
7
*Measured in 1m distance from the unit.
(1) EW 30°C; LW 35°C; ambient conditions: 7°CDB/6°CWB
(2) EW 30°C; LW 35°C; ambient conditions: 2°CDB/1°CWB
(3) EW 23°C; LW18°C; ambient conditions: 35°C
(4) EW 12°C; LW 7°C; ambient conditions 35°C
EHBX11CB3V
EHBX11CB9W*
EHBX16CB3V
EHBX16CB9W*
890x480x344 890x480x344
15~55 15~55
5~22 5~22
25~80 25~80
33 33
1~/230V / *3~/400V 1~/230V / *3~/400V
EHVH11S18CB3V
EHVH11S26CB9W*
EHVH16S18CB3V
EHVH16S26CB9W*
1.732x600x728 1.732x600x728
15~55 15~55
25~60 25~60
33 33
1~/230V / *3~/400V 1~/230V / *3~/400V
EHVX11S18CB3V
EHVX11S26CB9W*
EHVX16S18CB3V
EHVX16S26CB9W*
1.732x600x728 1.732x600x728
15~55 15~55
5~22 5~22
25~60 25~60
33 33
1~/230V / *3~/400V 1~/230V / *3~/400V
ERLQ11CV3 / ERLQ11CW1 ERLQ14CV3 / ERLQ14CW1 ERLQ16CV3 / ERLQ16CW1
– – –
11,201 / 8,562 14,501 / 10,302 16,001 / 11,102
11,381 14,551 16,101
15,053 / 11,724 16,063 / 12,554 16,763 / 13,124
4,601 / 3,602 4,301 / 3,452 4,251 / 3,352
3,323 / 2,724 2,963 / 2,474 2,723 / 2,294
1.345x900x320 1.345x900x320 1.345x900x320
-25~35 -25~35 -25~35
10~46 10~46 10~46
-20~35 -20~35 -20~35
51 51 52
50 52 54
1~/230V / 3~/400V 1~/230V / 3~/400V 1~/230V / 3~/400V
> Daikin Altherma low temperature split
EHBH11CB3V
EHBH11CB9W*
EHBH16CB3V
EHBH16CB9W*
890x480x344 890x480x344
25~55 25~55
25~80 25~80
33 33
1~/230V / *3~/400V 1~/230V / *3~/400V
8
Daikin Altherma Low Temperature Outdoor Unit
Inverter Split Heat pump outdoor unit with nominal capacities from 4 to 8 kW. Nominal capacity is measured at A7/W35**. PRICE CZK
Daikin Altherma 4 kW outdoor unit* ERLQ004CV3 Power Supply 1~ 230V 44.921,-
Daikin Altherma 6 kW outdoor unit ERLQ006CV3 Power Supply 1~ 230V 49.439,-
Daikin Altherma 8 kW outdoor unit ERLQ008CV3 Power Supply 1~ 230V 67.465,-
Daikin Altherma wallmounted indoor unit for heating only applications.
Controller is not included, EKRUCBL is mandatory for system operation. All basic necessary hydraulic components included.PRICE CZK
Wallmounted indoor unit 4kW with 3kW BUH* EHBH04CB3V Electrical Backup Heater 1~ 230V 69.562,-
Wallmounted indoor unit 6-8 kW with 3kW BUH EHBH08CB3V Electrical Backup Heater 1~ 230V 76.847,-
Wallmounted indoor unit 6-8kW with 3-9 kW BUH EHBH08CB9W Electrical Backup Heater 1~ 230V or 3~ 400V 80.749,-
Daikin Altherma wallmounted indoor unit for heating & cooling applications.
Controller is not included, EKRUCBL is mandatory for system operation. All basic necessary hydraulic components included. PRICE CZK
Wallmounted indoor unit 4kW with 3kW BUH* EHBX04CB3V Electrical Backup Heater 1~ 230V 75.915,-
Wallmounted indoor unit 6-8 kW with 3kW BUH EHBX08CB3V Electrical Backup Heater 1~ 230V 79.908,-
Wallmounted indoor unit 6-8kW with 3-9 kW BUH EHBX08CB9W Electrical Backup Heater 1~ 230V or 3~ 400V 83.629,-
Daikin Altherma Indoor unit (fl oorstanding with domestic hot water tank) for heating only applications.
Controller is not included, EKRUCBL is mandatory for system operation. All basic necessary hydraulic components included. PRICE CZK
Floorstanding indoor unit 4kW with 3kW BUH & 180L Tank* EHVH04S18CB3V Electrical Backup Heater 1~ 230V 101.236,-
Floorstanding indoor unit 6-8 kW with 3kW BUH & 180L Tank EHVH08S18CB3V Electrical Backup Heater 1~ 230V 108.550,-
Floorstanding indoor unit 6-8kW with 3-9 kW BUH & 260L Tank EHVH08S26CB9W Electrical Backup Heater 1~ 230V or 3~ 400V 116.561,-
Daikin Altherma Indoor unit (fl oorstanding with domestic hot water tank) for heating & cooling applications.
Controller is not included, EKRUCBL is mandatory for system operation. All basic necessary hydraulic components included. PRICE CZK
Floorstanding indoor unit 4kW with 3kW BUH & 180L Tank* EHVX04S18CB3V Electrical Backup Heater 1~ 230V 107.584,-
Floorstanding indoor unit 6-8 kW with 3kW BUH & 180L Tank EHVX08S18CB3V Electrical Backup Heater 1~ 230V 111.588,-
Floorstanding indoor unit 6-8kW with 3-9 kW BUH & 260L Tank EHVX08S26CB9W Electrical Backup Heater 1~ 230V or 3~ 400V 119.450,-
Daikin Altherma Low Temperature Outdoor Unit
Inverter Split Heat pump outdoor unit with nominal capacities from 11 to 16 kW. Nominal capacity is measured at A7/W35**PRICE CZK
Daikin Altherma 11 kW outdoor unit ERLQ011CV3 Power Supply 1~ 230V 70.005,-
Daikin Altherma 14 kW outdoor unit ERLQ014CV3 Power Supply 1~ 230V 83.397,-
Daikin Altherma 16 kW outdoor unit ERLQ016CV3 Power Supply 1~ 230V 94.700,-
Daikin Altherma Low Temperature Outdoor Unit
Inverter Split Heat pump outdoor unit with nominal capacities from 11 to 16 kW. Nominal capacity is measured at A7/W35**. PRICE CZK
Daikin Altherma 11 kW outdoor unit ERLQ011CW1 Power Supply 3~ 400V 78.197,-
Daikin Altherma 14 kW outdoor unit ERLQ014CW1 Power Supply 3~ 400V 91.956,-
Daikin Altherma 16 kW outdoor unit ERLQ016CW1 Power Supply 3~ 400V 113.863,-
Daikin Altherma wallmounted indoor unit for heating only applications.
Controller is not included, EKRUCBL is mandatory for system operation. All basic necessary hydraulic components included.PRICE CZK
Wallmounted indoor unit 11kW with 3KW BUH EHBH11CB3V Electrical Backup Heater 1~ 230V 81.600,-
Wallmounted indoor unit 11 kW with 3-9 kW BUH EHBH11CB9W Electrical Backup Heater 1~ 230V or 3~ 400V 86.700,-
Wallmounted indoor unit 16 kW with 3 kW BUH EHBH16CB3V Electrical Backup Heater 1~ 230V 88.603,-
Wallmounted indoor unit 16 kW with 3-9 kW BUH EHBH16CB9W Electrical Backup Heater 1~ 230V or 3~ 400V 93.058,-
Daikin Altherma wallmounted indoor unit for heating & cooling applications.
Controller is not included, EKRUCBL is mandatory for system operation. All basic necessary hydraulic components included.PRICE CZK
Wallmounted indoor unit 11kW with 3KW BUH EHBX11CB3V Electrical Backup Heater 1~ 230V 85.300,-
Wallmounted indoor unit 11 kW with 3-9 kW BUH EHBX11CB9W Electrical Backup Heater 1~ 230V or 3~ 400V 89.275,-
Wallmounted indoor unit 16 kW with 3 kW BUH EHBX16CB3V Electrical Backup Heater 1~ 230V 91.949,-
Wallmounted indoor unit 16 kW with 3-9 kW BUH EHBX16CB9W Electrical Backup Heater 1~ 230V or 3~ 400V 96.275,-
Daikin Altherma Indoor unit (fl oorstanding with domestic hot water tank) for heating only applications.
Controller is not included, EKRUCBL is mandatory for system operation. All basic necessary hydraulic components included. PRICE CZK
Floorstanding indoor unit 11 kW with 3kW BUH & 180 L Tank EHVH11S18CB3V Electrical Backup Heater 1~ 230V 116.800,-
Floorstanding indoor unit 11 kW with 3-9 kW BUH & 260 L Tank EHVH11S26CB9W Electrical Backup Heater 1~ 230V or 3~ 400V 124.200,-
Floorstanding indoor unit 16 kW with 3kW BUH & 180L Tank EHVH16S18CB3V Electrical Backup Heater 1~ 230V 118.168,-
Floorstanding indoor unit 16 kW with 3-9 kW BUH & 260 L Tank EHVH16S26CB9W Electrical Backup Heater 1~ 230V or 3~ 400V 126.459,-
▪ Pricelist
Daikin Altherma is a low temperature, inverter driven air to water split heat pump system. The outdoor unit is connected to the indoor unit (wallmounted or fl oorstanding) with refrigerant piping. The heat pump system can be used for space heating, space cooling and domestic hot water production.
> Daikin Altherma low temperature split
9
INDOOR UNIT
Wallmounted Floorstanding Wallmounted FloorstandingEHBH04CB3V
EHBX04CB3V
EHBH08CB3V
EHBX08CB3V
EHBH08CB9W
EHBX08CB9W
EHVH04S18CB3V
EHVX04S18CB3V
EHVH08S18CB3V
EHVX08S18CB3V
EHVH08S26CB9W
EHVX08S26CB9W
EHBH11CB*
EHBX11CB*
EHBH16CB*
EHBX16CB*
EHVH11S18CB*
EHVX11S18CB*
EHVH16S26CB*
EHVX16S26CB*
OU
TD
OO
R U
NIT
ERLQ004CV3 ● – – ● – – – – – –ERLQ006CV3 – ● ● – ● ● – – – –ERLQ008CV3 – ● ● – ● ● – – – –ERLQ011CV3 – – – – – – ● – ● –ERLQ014CV3 – – – – – – – ● – ●ERLQ016CV3 – – – – – – – ● – ●ERLQ011CW1 – – – – – – ● – ● –ERLQ014CW1 – – – – – – – ● – ●ERLQ016CW1 – – – – – – – ● – ●
*3V versions and 9W versions (1~ 230V and 3~ 400V versions)
▪ Combinations
Controller and User Interface, mandatory for each *CB unit. (Other languages you will fi nd on page 25)Applicable for:
PRICE CZK4-8kW 11-16kW
Controller EKRUCBL1 User interface with languages FR, NL, DE, IT ● ● 3.296,-
Controller EKRUCBL5 User interface with languages DE, SI, CZ, SK ● ● 3.296,-
Options & AccessoriesApplicable for:
PRICE CZK4-8kW 11-16kW
Drainpan for outdoor unit
(exl. drainpan heater)
EKDP008C Collect water from defrost cycle and drain via central hole to remote location.
If installed additional heater tape EKDPH00bC is mandatory!● 4.997,-
Heater tape for outdoor unit drainpan EKDPH008C Heater tape to install in central hole of drain pan to prevent ice blockage ● 7.555,-
Remote temperature sensor for outdoor unit EKRSC1 Ambient temperature measurement remotely from outdoor unit ● 2.617,-
U-beams for outdoor unit EKFT008CA Beams to mount outdoor unit on (height 25cm) ● 3.112,-
Remote indoor sensor KRCS01-1 Temperature measurement remotely from user interface ● ● 2.432,-
PC cable EKPCCAB2 Cable to upload fi eld settings from PC to unit ● ● 7.555,-
Drain pan kit for indoor unit EKHBDPC2 Collect and drain condensate during cooling operation ● ● 4.527,-
Wired room thermostat EKRTWA Wired Digital Room Thermostat ● ● 3.938,-
Wireless room thermostat EKRTR Wireless Digital Room Thermostat ● ● 6.713,-
Thermostat external sensor EKRTETS Temperature measurement remotely from wireless room thermostat (e.g. fl oor temperature) ● ● 516,-
Digital I/O PCB EKRP1HBA Remote alarm / operation status ● ● 4.144,-
Demand PCB EKRP1AHT Power consumption limitation with 4 digital inputs on hydrobox ● 4.158,-
Demand PCB KRP58M51 Power consumption limitation via outdoor unit ● 5.640,-
Solar Kit EKSOLHW Heat exchanger to connect Daikin solar system to EKHWS and EKHWE DHW tank ● ● 23.134,-
Electricity meter K.ELECMETV Single phase electricity meter ● ● 4.962,-
Electricity meter K.ELECMETW Three phase electricity meter ● ● 10.353,-
Domestic hot water connection kit for EKHWP300B H/O EKDVCPLT3H/X Connection kit for LT 4-8kW in combination with EKHWP300B ● 7.140,-
Domestic hot water connection kit for EKHWP500B H/O EKDVCPLT5H Connection kit for LT 4-16kW heating only in combination with EKHWP500B ● ● 15.049,-
Domestic hot water connection kit for EKHWP500B H/C EKDVCPLT5X Connection kit for LT 4-16kW heating & cooling in combination with EKHWP500B ● ● 19.967,-
Electrical Booster Heater EKBH3S Electrical booster heat for EKHWP-B tanks ● ● 9.803,-
Domestic Hot Water Tank Sets
(consists of tank, booster heater, contactor/fuse assembly for BH, tanksensor + 12m connection wire, 3 Way Valve + motor)
Applicable for:PRICE CZK
4-8kW 11-16kW
Stainless Steel Domestic Hot Water Tank 150L EKHWS150B3V3 incl. 3kW booster heater 1~ 230V, height 900mm, diameter 580mm, weight 37kg ● ● 30.657,-
Wallbracket for 150L stainless steel tank EKWBSWW150 ● ● 8.701,-
Stainless Steel Domestic Hot Water Tank 200L EKHWS200B3V3 incl. 3kW booster heater 1~ 230V, height 1150mm, diameter 580mm, weight 45kg ● ● 31.670,-
Stainless Steel Domestic Hot Water Tank 200L EKHWS200B3Z2 incl. 3kW booster heater 2~ 400V, height 1150mm, diameter 580mm, weight 45kg ● ● 31.670,-
Stainless Steel Domestic Hot Water Tank 300L EKHWS300B3V3 incl. 3kW booster heater 1~ 230V, height 1600mm, diameter 580mm, weight 59kg ● ● 35.814,-
Stainless Steel Domestic Hot Water Tank 300L EKHWS300B3Z2 incl. 3kW booster heater 2~ 400V, height 1600mm, diameter 580mm, weight 59kg ● ● 35.814,-
Enameled Domestic Hot Water Tank 150L EKHWE150A3V3 incl. 3kW booster heater 1~ 230V, height 1205mm, diameter 545mm, weight 80kg ● ● 25.556,-
Enameled Domestic Hot Water Tank 150L (wallmounted) EKHWET150A3V3 incl. 3kW booster heater 1~ 230V, height 1205mm, diameter 545mm, weight 82kg ● ● 26.620,-
Enameled Domestic Hot Water Tank 200L EKHWE200A3V3 incl. 3kW booster heater 1~ 230V, height 1580mm, diameter 545mm, weight 104kg ● ● 26.412,-
Enameled Domestic Hot Water Tank 200L EKHWE200A3Z2 incl. 3kW booster heater 2~ 400V, height 1580mm, diameter 545mm, weight 104kg ● ● 26.412,-
Enameled Domestic Hot Water Tank 300L EKHWE300A3V3 incl. 3kW booster heater 1~ 230V, height 1572mm, diameter 660mm, weight 140kg ● ● 29.815,-
Enameled Domestic Hot Water Tank 300L EKHWE300A3Z2 incl. 3kW booster heater 2~ 400V, height 1572mm, diameter 660mm, weight 140kg ● ● 29.815,-
Domestic Hot Water Tanks with pressureless buff er tank and hygienic domestic hot water production
(can be used for solar option)
Applicable for:PRICE CZK
4-8kW 11-16kW
Pressureless 300L Domestic Hot Water Tank EKHWP300B Pressureless hygienic domestic hot water tank with solar option for 4-8 kW LT heat pumps ● 44.212,-
Pressureless 500L Domestic Hot Water Tank EKHWP500B Pressureless hygienic domestic hot water tank with solar option for 4-16kW LT heat pumps ● ● 50.615,-
> Daikin Altherma low temperature split
Daikin Altherma Indoor unit (fl oorstanding with domestic hot water tank) for heating & cooling applications.
Controller is not included, EKRUCBL is mandatory for system operation. All basic necessary hydraulic components included. PRICE CZK
Floorstanding indoor unit 11 kW with 3 kW BUH & 180 L Tank EHVX11S18CB3V Electrical Backup Heater 1~ 230V 123.581,-
Floorstanding indoor unit 11 kW with 3-9 kW BUH & 260 L Tank EHVX11S26CB9W Electrical Backup Heater 1~ 230V or 3~ 400V 128.032,-
Floorstanding indoor unit 16 kW with 3kW BUH & 180L Tank EHVX16S18CB3V Electrical Backup Heater 1~ 230V 125.200,-
Floorstanding indoor unit 16 kW with 3-9 kW BUH & 260 L Tank EHVX16S26CB9W Electrical Backup Heater 1~ 230V or 3~ 400V 129.732,-
* The 4kW outdoor ERLQ004CV3 unit can only be combined with a 4kW indoor unit (either wallmounted or fl oorstanding)!
** Ta DB/WB 7°C / 6°C - LWC 35°C (DT = 5K)
11
Monobloc system
Outdoor unit:
11, 14 and 16 kW Under floor heating
Heat pump convectorDomestic hot water Solar connection (optional)
Everything combined in one outdoor unit
In addition to Daikin Altherma split systems, Daikin has introduced a monobloc
version in which all hydraulic parts are located within the outdoor unit.
In this system, the water pipes, rather than the refrigerant pipes, run indoors
from the outdoor unit, making installation much quicker and easier
for the domestic installer.
Available capacities for monobloc: 11, 14, 16 kW
> Daikin Altherma low temperature monobloc
12
THREE
PHASE
SINGLE
PHASE
HEATING ONLY
EDLQ011BC6V3 EDLQ014BC6V3 EDLQ016BC6V3
Heating capacity Nom. kW 11,201 / 8,112 14,001 / 9,722 16,001 / 10,692
Power input Heating Nom. kW 2,561 / 2,572 3,291 / 3,122 3,881 / 3,442
COP 4,381 / 3,162 4,251 / 3,122 4,121 / 3,112
Dimensions Unit Height X Width X Depth mm 1.418 X 1.435 X 382
Weight Unit kg 180
Hydraulic
component
Back-up
heater current
Type 6V3
Power
supply
Phase/Frequency/
Voltage
~/Hz/V1~/50/230
Operation range Heating Ambient Min.~Max. °C -20~35
Water side Min.~Max. °C 15 ~55
Domestic hot
water
Ambient Min.~Max. °C -20~43
Water side Min.~Max. °C 25~80
Refrigerant Type R-410A
Charge kg 2,95
Sound power level Heating Nom. dBA 64 65 66
Sound pressure level Heating Nom. dBA 51 52
Compressor
component
Main power
supply
Name V3
Phase 1~
Frequency Hz 50
Voltage V 230
(1) cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (nom. values according to EN14511)
(2) cooling Ta 35°C - LWE 7°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) (nom. values according to EN14511)
HEATING ONLY
EDLQ011BC6W1 EDLQ014BC6W1 EDLQ016BC6W1
Heating capacity Nom. kW 11,201 / 8,112 14,001 / 9,722 16,001 / 10,692
Power input Heating Nom. kW 2,601/ 2,612 3,301 / 3,132 3,811 / 3,442
COP 4,311 / 3,112 4,241 / 3,112 4,201 / 3,112
Dimensions Unit Height X Width X Depth mm 1.418 X 1.435 X 382
Weight Unit kg 180
Hydraulic
component
Back-up
heater current
Type 6W1
Power
supply
Phase/Frequency/
Voltage
~/Hz/V3~/50/400
Operation range Heating Ambient Min.~Max. °C -25~35
Water side Min.~Max. °C 15 ~55
Domestic hot
water
Ambient Min.~Max. °C -25~43
Water side Min.~Max. °C 25~80
Refrigerant Type R-410A
Charge kg 2,95
Sound power level Heating Nom. dBA 64 65 66
Sound pressure level Heating Nom. dBA 49 51 53
Compressor
component
Main power
supply
Name W1
Phase 3N~
Frequency Hz 50
Voltage V 400
(1) cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (nom. values according to EN14511)
(2) cooling Ta 35°C - LWE 7°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) (nom. values according to EN14511)
> Daikin Altherma low temperature monobloc
▪ Technical specifi cations
13
SINGLE
PHASE
THREE
PHASE
HEATING & COOLING
EBLQ011BC6V3 EBLQ014BC6V3 EBLQ016BC6V3
Heating capacity Nom. kW 11,201 / 8,112 14,001 / 9,722 16,001 / 10,692
Cooling capacity Nom. kW 12,851 / 10,002 15,991 / 12,502 16,731 / 13,102
Power input Cooling Nom. kW 3,871 / 3,692 5,751 / 5,392 6,361 / 5,932
Heating Nom. kW 2,561 / 2,572 3,291 / 3,122 3,881 / 3,442
COP 4,381 / 3,162 4,251 / 3,122 4,121 / 3,112
EER 3,321 / 2,712 2,781 / 2,322 2,631 / 2,212
Dimensions Unit Height X Width X Depth mm 1.418 X 1.435 X 382
Weight Unit kg 180
Hydraulic
component
Back-up
heater current
Type 6V3
Power
supply
Phase/Frequency/
Voltage
~/Hz/V1~/50/230
Operation range Heating Ambient Min.~Max. °C -20~35
Water side Min.~Max. °C 15~55
Cooling Ambient Min.~Max. °C 10~46
Water side Min.~Max. °C 5~22
Domestic hot
water
Ambient Min.~Max. °C -20~43
Water side Min.~Max. °C 25~80
Refrigerant Type R-410A
Charge kg 2,95
Sound power level Heating Nom. dBA 64 65 66
Cooling Nom. dBA 65 66 69
Sound pressure
level
Heating Nom. dBA 5 52
Cooling Nom. dBA 50 52 54
Compressor
component
Main power
supply
Name V3
Phase 1~
Frequency Hz 50
Voltage V 230
(1) cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)(nom. values according to EN14511)
(2) cooling Ta 35°C - LWE 7°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) (nom. values according to EN14511)
HEATING & COOLING
EBLQ011BC6W1 EBLQ014BC6W1 EBLQ016BC6W1
Heating capacity Nom. kW 11,201 / 8,112 14,001 / 9,722 16,001 / 10,692
Cooling capacity Nom. kW 12,851 / 10,002 15,991 / 12,502 16,731 / 13,102
Power input Cooling Nom. kW 3,871 / 3,692 5,401/ 5,062 6,151 / 5,752
Heating Nom. kW 2,601/ 2,612 3,301 / 3,132 3,811 / 3,442
COP 4,311 / 3,112 4,241 / 3,112 4,201 / 3,112
EER 3,321 / 2,712 2,961 / 2,472 2,721 / 2,282
Dimensions Unit Height X Width X Depth mm 1.418 X 1.435 X 382
Weight Unit kg 180
Hydraulic
component
Back-up
heater current
Type 6W1
Power
supply
Phase/Frequency/
Voltage
~/Hz/V3~/50/400
Operation range Heating Ambient Min.~Max. °C -25~35
Water side Min.~Max. °C 15~55
Cooling Ambient Min.~Max. °C 10~46
Water side Min.~Max. °C 5~22
Domestic hot
water
Ambient Min.~Max. °C -25~43
Water side Min.~Max. °C 25~80
Refrigerant Type R-410A
Charge kg 2,95
Sound power level Heating Nom. dBA 64 65 66
Cooling Nom. dBA 65 66 69
Sound pressure
level
Heating Nom. dBA 49 51 53
Cooling Nom. dBA 50 52 54
Compressor
component
Main power
supply
Name W1
Phase 3N~
Frequency Hz 50
Voltage V 400
(1) cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (nom. values according to EN14511)
(2) cooling Ta 35°C - LWE 7°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) (nom. values according to EN14511)
> Daikin Altherma low temperature monobloc
14
▪ Pricelist
Daikin Altherma monobloc is designed as a compact unit, including
refrigeration cycle and all necessary parts of the water cycle in the units
casing.
Daikin Altherma monobloc simply has to be connected to water pipings,
without the need for refrigeration piping done by the installer.
Beside hydraulic parts such as water pump, expansion vessel, safety valve,
water fi lter and fl ow switch monobloc also includes a 6 kW factory mounted
backup heater, which can be reduced during commissioning to a minimum
of 2 kW (400V heater) or 3 kW (230V heater).
Daikin Altherma low temperature monobloc heating only
Inverter monobloc heat pump with nominal capacities from 11 to 16 kW. Nominal capacity is measured at A7/W35. PRICE CZK
Daikin Altherma 11kW Monobloc 230V EDLQ011BC6V3 6kW BUH, Power Supply 1~ 230V 162.600,-
Daikin Altherma 14kW Monobloc 230V EDLQ014BC6V3 6kW BUH, Power Supply 1~ 230V 178.000,-
Daikin Altherma 14kW Monobloc 230V EDLQ016BC6V3 6kW BUH, Power Supply 1~ 230V 191.600,-
Daikin Altherma 11kW Monobloc 400V EDLQ011BC6W1 6kW BUH, Power Supply 3~ 400V 177.000,-
Daikin Altherma 14kW Monobloc 400V EDLQ014BC6W1 6kW BUH, Power Supply 3~ 400V 194.000,-
Daikin Altherma 14kW Monobloc 400V EDLQ016BC6W1 6kW BUH, Power Supply 3~ 400V 209.000,-
Daikin Altherma low temperature monobloc heating & cooling
Inverter monobloc heat pump with nominal capacities from 11 to 16 kW. Nominal capacity is measured at A7/W35. PRICE CZK
Daikin Altherma 11kW Monobloc 230V EBLQ011BC6V3 6kW BUH, Power Supply 1~ 230V 169.000,-
Daikin Altherma 14kW Monobloc 230V EBLQ014BC6V3 6kW BUH, Power Supply 1~ 230V 184.900,-
Daikin Altherma 14kW Monobloc 230V EBLQ016BC6V3 6kW BUH, Power Supply 1~ 230V 198.200,-
Daikin Altherma 11kW Monobloc 400V EBLQ011BC6W1 6kW BUH, Power Supply 3~ 400V 183.300,-
Daikin Altherma 14kW Monobloc 400V EBLQ014BC6W1 6kW BUH, Power Supply 3~ 400V 200.300,-
Daikin Altherma 14kW Monobloc 400V EBLQ016BC6W1 6kW BUH, Power Supply 3~ 400V 216.000,-
> Daikin Altherma low temperature monobloc
15
Options & accessoriesApplicable for:
11-16kWPRICE CZK
Wired room thermostat EKRTWA Wired Digital Room Thermostat ● 3.938,-
Wireless room thermostat EKRTR Wireless Digital Room Thermostat ● 6.713,-
Digital I/O PCB EKRP1HBA Remote alarm / operation status / … ● 4.144,-
Thermostat external sensor EKRTETS Temperature measurement remotely from wireless
room thermostat (e.g. fl oor temperature) ● 516,-
Solar Kit EKSOLHW Heat exchanger to connect Daikin solar system to EKHWS and EKHWE DHW tank ● 23.134,-
Domestic hot water connection kit for
EKHWP500B H/O
EKDVCPLT5H Connection kit for EDLQ heating only models
in combination with EKHWP500B ● 15.049,-
Domestic hot water connection kit for
EKHWP500B H/C
EKDVCPLT5X Connection kit for EBLQ heating & cooling models
in combination with EKHWP500B ● 19.967,-
Electrical Booster Heater EKBH3S Electrical booster heat for EKHWP-B tanks ● 9.803,-
Domestic hot water tanks (can be used for solar option)Applicable for:
11-16kWPRICE CZK
Stainless Steel Domestic Hot Water Tank 150L EKHWS150B3V3 incl. 3kW booster heater 1~ 230V, height 900mm, diameter 580mm, weight 37kg ● 30.657,-
Wallbracket for 150L stainless steel tank EKWBSWW150 ● 8.701,-
Stainless Steel Domestic Hot Water Tank 200L EKHWS200B3V3 incl. 3kW booster heater 1~ 230V, height 1150mm, diameter 580mm, weight 45kg ● 31.670,-
Stainless Steel Domestic Hot Water Tank 200L EKHWS200B3Z2 incl. 3kW booster heater 2~ 400V, height 1150mm, diameter 580mm, weight 45kg ● 31.670,-
Stainless Steel Domestic Hot Water Tank 300L EKHWS300B3V3 incl. 3kW booster heater 1~ 230V, height 1600mm, diameter 580mm, weight 59kg ● 35.814,-
Stainless Steel Domestic Hot Water Tank 300L EKHWS300B3Z2 incl. 3kW booster heater 2~ 400V, height 1600mm, diameter 580mm, weight 59kg ● 35.814,-
Enameled Domestic Hot Water Tank 150L EKHWE150A3V3 incl. 3kW booster heater 1~ 230V, height 1205mm, diameter 545mm, weight 80kg ● 25.556,-
Enameled Domestic Hot Water Tank 150L
(wallmounted)
EKHWET150A3V3 incl. 3kW booster heater 1~ 230V, height 1205mm, diameter 545mm, weight 82kg ● 26.620,-
Enameled Domestic Hot Water Tank 200L EKHWE200A3V3 incl. 3kW booster heater 1~ 230V, height 1580mm, diameter 545mm, weight 104kg ● 26.412,-
Enameled Domestic Hot Water Tank 200L EKHWE200A3Z2 incl. 3kW booster heater 2~ 400V, height 1580mm, diameter 545mm, weight 104kg ● 26.412,-
Enameled Domestic Hot Water Tank 300L EKHWE300A3V3 incl. 3kW booster heater 1~ 230V, height 1572mm, diameter 660mm, weight 140kg ● 29.815,-
Enameled Domestic Hot Water Tank 300L EKHWE300A3Z2 incl. 3kW booster heater 2~ 400V, height 1572mm, diameter 660mm, weight 140kg ● 29.815,-
Pressureless 500L Domestic Hot Water Tank EKHWP500B Pressureless hygienic domestic hot water tank with solar option ● 50.615,-
> Daikin Altherma low temperature monobloc
16
Domestic hot
water tank
For replacement of traditional boilers
Indoor unit
Outdoor unit
Solar connection (optional)
Daikin Altherma high temperature system off ers heating and domestic hot
water for your home. This system can perfectly replace a traditional boiler and
connect to the existing piping. Daikin Altherma high temperature is therefore
the ideal solution for renovations. The split system consists of an outdoor unit and
an indoor unit and can be completed with solar connection.
> Daikin Altherma high temperature
17
A split system consists of an outdoor unit and an indoor unit
The Daikin Altherma outdoor unit includes a heat pump that extracts heat from the outside air resulting in nearly 2/3 of all
usable heat coming from a sustainable and free source.
The outdoor unit extracts heat from the ambient outdoor air. This heat is transferred to the indoor unit via refrigerant piping.
The indoor unit receives the heat from the outdoor unit and further increases the temperature, allowing water temperatures
up to 80°C for heating through radiators and for domestic hot water use. Daikin’s unique cascade compressor approach
to the heat pumps (one in the outdoor unit/one in the indoor unit) means optimum comfort at even the coldest outdoor
temperatures, without the need for an electric back-up heater.
Daikin Altherma high temperature heats up to 3 times more effi ciently than a traditional heating system based on fossil
fuels or electricity. A lower running cost is thus achieved, while you can still enjoy a stable and pleasant level of comfort.*
* COP (Coeffi cient of Performance) of up to 3.08
Daikin Altherma’s high water temperature is ideal for heating domestic hot water without the need for an additional electric
heater. Rapid heating of domestic hot water also means smaller heaters are needed. For a family of approximately 4 people,
the standard tank is the best solution. Should you require more hot water, a larger tank is also available.
Heat emitters
The Daikin Atherma high temperature system is designed
to work with high-temperature radiators, which come in
various sizes and formats to suit the interior design as well as
the heating requirement. The radiators can be individually
controlled or they can be regulated by the central heating
control programme.
Solar connection
The Daikin Altherma high temperature heating system can
optionally use solar energy for hot water production.
If the solar energy is not required immediately, the purpose-
built hot water tank (EKHWP) can store large quantities of
heated water for up to a day for later use as domestic hot
water or for heating.
Domestic hot water tank
Split system
18
▪ Technical specifi cations
OUTDOOR UNIT ERRQ011AV1 ERRQ014AV1 ERRQ016AV1 ERRQ011AY1 ERRQ014AY1 ERRQ016AY1
Heating capacity Nom. kW 11 1 / 11 2 14 1 / 14 2 16 1 / 16 2 11 1 / 11 2 14 1 / 14 2 16 1 / 16 2
Power input Heating Nom. kW 3,57 1 / 4,40 2 4,66 1 / 5,65 2 5,57 1 / 6,65 2 3,57 1 / 4,402 4,66 1 / 5,65 2 5,57 1 / 6,65 2
COP 3,08 1 / 2,50 2 3,00 1 / 2,48 2 2,88 1 / 2,41 2 3,08 1 / 2,50 2 3,00 1 / 2,48 2 2,88 1 / 2,41 2
Dimensions Unit H x W x D mm 1.345x900x320
Weight Unit kg 120
Operation
range
Heating Min.~Max. °CWB -20~20
Domestic hot water Min.~Max. °CDB -20~35
Refrigerant Type R-410A
Charge kg 4,5
Sound power level Heating Nom. dBA 68 69 71 68 69 71
Sound pressure level Heating Nom. dBA 52 53 55 52 53 55
Power supply Name/Phase/Frequency/Voltage Hz/V 1~/50/220-440 3~/50/380-415
Current Recommended fuses A 25 16
(1) EW 55ºC; LW 65ºC; Dt 10ºC; ambient conditions: 7ºCDB/6ºCWB
(2) EW 70ºC; LW 80ºC; Dt 10ºC; ambient conditions: 7ºCDB/6ºCWB
INDOOR UNIT - fl oor standing EKHBRD011ACV1 EKHBRD014ACV1 EKHBRD016ACV1 EKHBRD011ACY1 EKHBRD014ACY1 EKHBRD016ACY1
Casing Colour Metallic grey
Material Precoated sheet metal
Dimensions Unit H x W x D mm 705x600x695
Weight Unit kg 144,25 147,25
Operation
range
Heating Ambient Min.~Max. °C -20~20
Water side Min.~Max. °C 25~80
Domestic hot
water
Ambient Min.~Max. °CDB -20~35
Water side Min.~Max. °C 25~80
Refrigerant Type R-134a
Charge kg 3,2
Sound pressure
level
Nom. dBA 43 / 46 45 / 46 46 / 46 43 / 46 45 / 46 46 / 46 43 / 46 45 / 46 46 / 46 43 / 46 45 / 46 46 / 46
Night quiet mode Level 1 dBA 40 43 45 40 43 45 40 43 45 40 43 45
Power supply Name V1 Y1
Phase 1~ 3~
Frequency Hz 50
Voltage V 220-240 380-415
Current Recommended fuses A 25 16
> Daikin Altherma high temperature
19
Domestic hot water tank EKHTS200AC EKHTS260AC
Casing Colour Metallic grey
Material Galvanised steel (precoated sheet metal)
Dimensions Unit H x W x D mm 2.010x600x695 2.285x600x695
Weight Unit Empty kg 70 78
Tank Water volume l 200 260
Material Stainless steel (EN 1.4521)
Maximum water temperature °C 75
Insulation Heat loss kWh/24h 1,2 1,5
Heat exchanger Quantity 1
Tube material Duplex steel (EN 1.4162)
Face area m² 1,56
Internal coil volume l 7,5
Domestic hot water tank EKHWP300B EKHWP500B
Dimensions Unit Height mm 1.640 1.640
Width mm 595 790
Depth mm 615 790
Weight Unit Empty kg 59 93
Tank Water volume l 300 500
Maximum water temperature °C 85
Insulation Heat loss kWh/24h 1,3 1,4
Heat exchanger Domestic hot
water
Tube material Stainless steel
Face area m² 5,8 6
Internal coil volume l 27,9 29
Operating pressure bar 6
Average specifc thermal output W/K 2.790 2.900
Charging Tube material Stainless steel
Face area m² 2,7 3,8
Internal coil volume l 13,2 18,5
Operating pressure bar 3
Average specifc thermal output W/K 1.300 1.800
Auxiliary solar
heating
Tube material Stainless steel
Face area m² - 0,5
Internal coil volume l - 2,3
Operating pressure bar 3
Average specifc thermal output W/K - 280
Solar collector EKSH26P EKSV21P EKSV26P
Dimensions Unit H x W x D mm 1.300x2.000x85 2.000x1.006x85 2.000x1.300x85
Weight Unit kg 42 35 42
Volume l 2,1 1,3 1,7
Surface Outer m² 2,6 2,01 2,6
Aperture m² 2,350 1,79 2,35
Absorber m² 2,360 1,8 2,36
Coating Micro-therm (absorption max.96%, Emission ca. 5% +/-2%)
Absorber Harp-shaped copper pipe register with laser-welded highly selective coated aluminium plate
Glazing Single pane safety glass, transmission +/- 92%
Allowed roof angle Min.~Max. ° 15~80
Operating pressure Max. bar 6
Stand still temperature Max. °C 200
Thermal performance Zero loss collector effi ciency η0 % -
Solar controller EKSRPS3
Mounting On side of tank
Dimensions Unit H x W x D mm 815x230x142
Thermal performance Zero loss collector effi ciency η0 % -
Control Type Digital temperature diff erence controller with plain text display
Power consumption W 2
Sensor Solar panel temperature sensor Pt1000
Storage tank sensor PTC
Return fl ow sensor PTC
Feed temperature and fl ow sensor Voltage signal (3,5V DC)
Power supply Voltage V 230
> Daikin Altherma high temperature
20
▪ Pricelist
Daikin Altherma HT represents the most innovative solution for refurbishment
projects. Equipped with a double inverter cascade system, it can produce
leaving water temperatures up to 80°C, reached purely on thermodynamic
principles – without an additional direct electrical heater.
Change a boiler directly to Daikin Altherma HT - your radiators can stay, no
additional investments are necessary.
Daikin Altherma high temperature outdoor units
Inverter Split Heat pump System with nominal capacities from 11 to 16 kW. Nominal capacity is measured at A7/W65, delta T 5K.
Can only be combined with an indoor unit of the same capacity class and power supply.
PRICE CZK
Daikin Altherma HT 11kW outdoor unit ERRQ011AV1 Power Supply 1~ 230V 80.161,-
Daikin Altherma HT 14kW outdoor unit ERRQ014AV1 Power Supply 1~ 230V 95.810,-
Daikin Altherma HT 16kW outdoor unit ERRQ016AV1 Power Supply 1~ 230V 108.783,-
Daikin Altherma HT 11kW outdoor unit ERRQ011AY1 Power Supply 3~400V 91.794,-
Daikin Altherma HT 14kW outdoor unit ERRQ014AY1 Power Supply 3~400V 108.434,-
Daikin Altherma HT 16kW outdoor unit ERRQ016AY1 Power Supply 3~400V 123.637,-
Daikin Altherma high temperature indoor units (fl oorstanding) for heating only applications.
All basic necessary hydraulic components included. Domestic Hot water tank can be mounted on top of or next to the indoor unit
as an option. Can only be combined with an outdoor unit of the same capacity class and power supply.
PRICE CZK
Daikin Altherma HT 11kW indoor unit EKHBRD011ACV1 Floorstanding unit, power supply 1~ 230V 127.626,-
Daikin Altherma HT 14kW indoor unit EKHBRD014ACV1 Floorstanding unit, power supply 1~ 230V 132.500,-
Daikin Altherma HT 16kW indoor unit EKHBRD016ACV1 Floorstanding unit, power supply 1~ 230V 136.574,-
Daikin Altherma HT 11kW indoor unit EKHBRD011ACY1 Floorstanding unit, power supply 3~ 400V 131.235,-
Daikin Altherma HT 14kW indoor unit EKHBRD014ACY1 Floorstanding unit, power supply 3~ 400V 136.429,-
Daikin Altherma HT 16kW indoor unit EKHBRD016ACY1 Floorstanding unit, power supply 3~ 400V 141.177,-
INDOOR UNIT
EKHBRD011ACV1 EKHBRD014ACV1 EKHBRD016ACV1 EKHBRD011ACY1 EKHBRD014ACY1 EKHBRD016ACY1
230V 400V
OU
TD
OO
R U
NIT
23
0V
ERRQ011AV1 ● - – – – –ERRQ014AV1 – ● – – – –ERRQ016AV1 – – ● – – –
40
0V
ERRQ011AY1 – – – ● – –ERRQ014AY1 – – – – ● –ERRQ016AY1 – – – – – ●
Daikin Altherma cascade technology
High performance in 3 steps:
1 The outdoor unit extracts heat
from the ambient outdoor air. This
heat is transferred to the indoor unit
via R-410A refrigerant.
> Daikin Altherma high temperature
▪ Combinations
21
Options & accessoriesApplicable for:
11-16kWPRICE CZK
Wired room thermostat EKRTWA Wired Digital Room Thermostat ● 3.938,-
Wireless room thermostat EKRTR Wireless Digital Room Thermostat ● 6.713,-
Digital I/O PCB EKRP1HBA Remote alarm / operation status / … ● 4.144,-
Modbus PCD RTD-W Monitoring and control ModBus interface ● 10.538,-
Sequencing Controller EKCC-W Master/slave control kit that can control and monitor up
to 16 hydroboxes, connected through RTD-W ● 28.562,-
Thermostat external sensor EKRTETS Temperature measurement remotely from wireless
room thermostat (e.g. fl oor temperature) ● 516,-
Demand PCB for connection of room
thermostat or backup heater
EKRP1AHT Required when EKRTWA or EKRTR is used as a room
thermostat or if a backup heater is installed ● 4.158,-
Remote user interface EKRUAHTB Can be used as a second user interface (master/slave)
besides the one delivered with the indoor unit ● 6.177,-
In-line backup heater 1~, 230V, 6kW EKBUHA6V3 Electrical backup heater for space heating support only ● 18.198,-
In-line backup heater 3~, 400V, 6kW EKBUHA6W1 Electrical backup heater for space heating support only ● 18.198,-
Option kit for standalone tank EKFMAHTB Kit required when EKHTS tanks are to be placed next to the indoor unit ● 15.427,-
Domestic hot water connection kit for
EKHWP300B
EKEPHT3H Connection kit for HT in combination with EKHWP300B ● 7.836,-
Domestic hot water connection kit for
EKHWP500B
EKEPHT5H Connection kit for HT in combination with EKHWP500B ● 14.066,-
Domestic hot water tanksApplicable for:
11-16kWPRICE CZK
Stainless steel domestic hot water tank
200LEKHTS200AC
Domestic hot water tank 200L, Dimensions HxBxT = 1.335x600x695,
height increases to 2.010 mm if mounted on top of indoor unit ● 41.962,-
Stainless steel domestic hot water tank
260LEKHTS260AC
Domestic hot water tank 260L, Dimensions HxBxT = 1.610x600x695,
height increases to 2.285 mm if mounted on top of indoor unit ● 47.397,-
Pressureless 300L domestic hot water tank EKHWP300B Pressureless hygienic domestic hot water tank with solar option ● 44.212,-
Pressureless 500L domestic hot water tank EKHWP500B Pressureless hygienic domestic hot water tank with solar option ● 50.615,-
Outdoor Indoor
1 2 3Step Step Step
3
2 The indoor unit receives the heat
and further increases the temperature
with R-134a refrigerant.
The heat is transferred from the R-134a
refrigerant circuit to the water circuit.
Thanks to the unique cascade compressor
approach, water temperatures of 80°
C can be reached without using an
additional back-up heater.
> Daikin Altherma high temperature
22
There is a growing demand from home owners to replace heating systems, especially replacing
of gas boilers, with more effi cient, more cost-eff ective and more environmentally friendly systems
that reduce CO2 emissions, reduce energy consumption and protect their budget.
The answer is the Rotex hybrid heat pump.
For space heating, the Rotex hybrid heat pump will combine air-to-water heat pump technology with gas condensing technology by searching for the optimum economical condition for its operation,
combining parameters of energy costs (electricity, gas), heat pump effi ciency and heat load
requirements to deliver up to 35% more heating effi ciency, plus major cost savings.
For domestic hot water, the Rotex hybrid heat pump optimises the operation
of the most effi cient gas condensing boiler.
Hybrid technol
ogy
> Rotex hybrid heat pump
For replacement of a gas boiler
A unique opportunity in residential heating!
Your benefi ts ü Low running costs for heating
and domestic hot water
compared to traditional boilers
ü Low investment cost
ü Provides suffi cient heat in
renovation applications
ü Easy and fast installation
NEW!
23
Hybrid operation
-7 0 15
Required
heat output
kWh/°C
Ambient
temperature °C
Gas
operation
Heat pump
operation
Looking at an average European climate, the largest part of the required heat output is covered by the hybrid and
heat pump operation, resulting in up to 35% more heating effi ciency.
1800
1600
1400
1200
1000
800
600
400
200
0
Illustration of an average European climate
+ 35% effi ciency (space heating) compared to condensing boiler
• Heat load: 14 kW
• 70% heat pump output
• 30% gas boiler output
Heat load = the capacity of the space heating system required to maintain comfortable indoor temperatures at any time.
Required heat output = heat load x n° of occuring hours per year
Heat pump operation
The heat pump integrated in the Rotex hybrid heat pump is the best available technology for optimizing running costs
at moderate outdoor temperatures, resulting in a coeffi cient of performance of 5,041 !
(1) heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
Gas operation
When outdoor temperatures are dropping drastically, it is no longer effi cient to operate in hybrid mode. At that point,
the unit will switch automatically to gas operation only.
Hybrid operation
If a high heat load is required, or to achieve the highest effi ciencies at the current conditions, both the gas boiler and heat pump
operate at the same time in the most economical way.
The water fl ow rate will be automatically regulated, in order to have the possibility of lowering the temperature of the water
fl owing from the radiators to the heat pump and so maximizing heat pump effi ciency.
The exact time the switch-over is made from heat pump operation to hybrid operation depends on the house characteristics,
energy prices and the requested indoor temperature setting.
> Rotex hybrid heat pump NEW!
24
HEATING ONLY
INDOOR UNIT RHYHBH05AAV3 RHYHBH08AAV3 RHYKOMB33AA3
Casing Colour White White - RAL9010
Material Precoated sheet metal
Dimensions Unit H x W x D mm 902x450x164 710x450x240
Weight Unit kg 30 31,2 36
Operation
range
Heating Ambient Min.~Max. °C -25~25 -~-
Water side Min.~Max. °C 25~55 15 (1)~80 (1)
Domestic hot water Water side Min.~Max. °C -~- 40~65
Power supply Name/Phase/Frequency/Voltage Hz/V V3 / 1~ / 50 / 230 -
(1) DB/WB 7°C/6°C - LWC 35°C (DT=5°C), boiler bypassed
OUTDOOR UNIT RVLQ05CV3 RVLQ08CV3
Heating
capacity
Min. kW 1,80 (1) / 1,80 (2)
Nom. kW 4,40 (1) / 4,03 (2) / 3,27 (3) 7,40 (1) / 6,89 (2) / 5,80 (3)
Max. kW 5,12 (1) / 4,90 (2) / 4,81 (3) 10,02 (1) / 9,53 (2) / 7,68 (3)
Power input Heating Nom. kW 0,87 (1) / 1,13 (2) / 1,23 (3) 1,66 (1) / 2,01 (2) / 1,64 (3)
COP 5,04 (1) / 3,58 (2) / 4,02 (3) 4,45 (1) / 3,42 (2) / 3,53 (3)
Dimensions Unit H x W x D mm 735x832x307
Weight Unit kg 54 56
Operation range Heating Min.~Max. °CWB -25~25
Refrigerant Type R-410A
Charge kg 1,45 1,60
Sound power level Heating Nom. dBA 61 62
Sound pressure level Heating Nom. dBA 48 49
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230
Current Recommended fuses A 20
(1) Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C); (2) Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C); (3) Condition: Ta DB/WB 2°C/1°C - LWC 35°C (Dt=5°C)
HEATING & COOLING
INDOOR UNIT RHYHBX08AAV3 RHYKOMB33AA3
Casing Colour White White - RAL9010
Material Precoated sheet metal
Dimensions Unit H x W x D mm 902x450x164 710x450x240
Weight Unit kg 31,2 36
Operation
range
Heating Ambient Min.~Max. °C -25~25 -~-
Water side Min.~Max. °C 25~55 15 (1)~80 (1)
Cooling Ambient Min.~Max. °C 10~43 -
Water side Min.~Max. °C 5~22 -
Domestic hot water Water side Min.~Max. °C -~- 40~65
Power supply Name V3 -
Phase 1~
Frequency Hz 50
Voltage V 230
OUTDOOR UNIT RVLQ08CV3
Heating
capacity
Min. kW 1,80 (1) / 1,80 (2)
Nom. kW 7,40 (1) / 6,89 (2) / 5,80 (3)
Max. kW 10,02 (1) / 9,53 (2) / 7,68 (3)
Cooling
capacity
Min. kW 2,50 (4) / 2,50 (5)
Nom. kW 6,86 (4) / 5,36 (5)
Power input Heating Nom. kW 1,66 (1) / 2,01 (2) / 1,64 (3)
Cooling Nom. kW 2,01 (4) / 2,34 (5)
COP 4,45 (1) / 3,42 (2) / 3,53 (3)
EER 3,41 (4) / 2,29 (5)
Dimensions Unit H x W x D mm 735x832x307
Weight Unit kg 56
Operation range Heating Min.~Max. °CWB -25~25
Refrigerant Type R-410A
Charge kg 1,60
Sound power level Heating Nom. dBA 62
Sound pressure level Heating Nom. dBA 49 (3)
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230
Current Recommended fuses A 20
(1) Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C); (2) Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C); (3) Condition: Ta DB/WB 2°C/1°C - LWC 35°C (Dt=5°C)
(4) Cooling: Ta 35°C - LWE 18°C (DT=5°C); (5) Cooling: Ta 35°C - LWE 7°C (DT=5°C)
▪ Technical specifi cations
> Rotex hybrid heat pump NEW!
25
▪ Pricelist
Daikin Altherma hybrid heat pump combines air-to-water heat pump technology with gas condensing technology by
searching for the optimum economical condition for its operation, combining parameters of energy costs (electricity, gas),
heat pump effi ciency and heat load requirements to deliver up to 35% more heating effi ciency, giving major cost savings.
Please note that a complete hybrid system consists of one outdoor unit, one hydro module, one gas boiler module, one
user interface and one cover plate.
DAIKIN Altherma hybrid heat pump - outdoor units PRICE CZK
Rotex Hybrid Outodoor unit 5kW RVLQ05CV3 Power Supply 1~ 230V 40.641,-
Rotex Hybrid Outodoor unit 8kW RVLQ08CV3 Power Supply 1~ 230V 58.276,-
DAIKIN Altherma hybrid heat pump - hydro module
(Controller needs to be ordered separately!)PRICE CZK
Rotex Hybrid indoor unit for 5kW
outdoor unit, heating only
RHYHBH05AAV3 power supply 1~ 230V, incl. high effi ciency pump, expansion vessle,
safety valve assembly, fl ow guard...etc. (W x D x H) 450 x 164 x 902
34.714,-
Rotex Hybrid indoor unit for 8kW
outdoor unit, heating only
RHYHBH08AAV3 power supply 1~ 230V, incl. high effi ciency pump, expansion vessle,
safety valve assembly, fl ow guard...etc. (W x D x H) 450 x 164 x 902
36.552,-
Rotex Hybrid indoor unit for 8kW
outdoor unit, heating & cooling
RHYHBX08AAV3 power supply 1~ 230V, incl. high effi ciency pump, expansion vessle,
safety valve assembly, fl ow guard...etc. (W x D x H) 450 x 164 x 902
38.568,-
DAIKIN Altherma hybrid heat pump - gas condensing combi boiler* PRICE CZK
Rotex Hybrid
Gas condensing combi boiler
7,9 - 31,9kW (80°C/60°C)
RHYKOMB33AA3 gas condensing combi boiler with special 2 in 1 heat exchanger for
space heating and instantaneous domestic hot water production,
for natural and liquid gas, (W x D x H) 450 x 240 x 710
51.351,-
*The gas boiler module is standard equipped with a concentric fl ue gas connection diameter 60/100.
*The gas boiler is certifi ed for following fl ue gas systems : C13, C33, C43, C53, C63, C83
Necessary accessories for a complete installation
(please only order one of the 7 controllers listed below)
Applicable for:PRICE CZK
5kW model 8kW model
Remote Controller RKRUCBL1 User interface with languages FR, NL, DE, IT ● ● 3.296,-
Remote Controller RKRUCBL2 User interface with languages EN, SV, FI, NO ● ● 3.296,-
Remote Controller RKRUCBL3 User interface with languages EN, ES, PT, EL ● ● 3.296,-
Remote Controller RKRUCBL4 User interface with languages EN, RO, PL, TR ● ● 3.296,-
Remote Controller RKRUCBL5 User interface with languages DE, SI, CZ, SK ● ● 3.296,-
Remote Controller RKRUCBL6 User interface with languages EN, HR, HU, BG ● ● 3.296,-
Remote Controller RKRUCBL7 User interface with languages EN, DA, RU, LT ● ● 3.296,-
Cover plate EKHY093467 Cover plate to hide the pipe
connections underneath the unit ● ● 671,-
Optional Accessories PRICE CZK
Propane Set EKHY075787 Kit for connection with liquid gas supply ● ● 305,-
Valve kit EKVK1A Valves for space heating, domestic
hot water an gas connection ● ● 3.478,-
Mounting jig EKHYMNT1A Jig to help mount the indoor unit onto the wall ● ● 7.479,-
Flue gas connector EKHY090707 connection for 2x80 parallel
connection (C53/C83) ● ● 488,-
Double-walled connection set EKHY090717 Concentric connection set from
DN 60/100 to DN 80/125 ● ● 549,-
U-beams for outdoor unit EKFT008CA Beams to mount outdoor unit on (height 25cm) ● ● 3.112,-
PC cable EKPCCAB2 Cable to upload fi eld settings from PC to unit ● ● 7.555,-
Drain pan kit for indoor unit EKHYDP Collect and drain condensate
during cooling operation ● ● 3.296,-
Drainpan for outdoor unit (exl. drainpan heater) EKDP008C Collect water from defrost cycle and drain
via central hole to remote location ● ● 4.997,-
Heater tape for outdoor unit drainpan EKDPH008C Heater tape to install in central hole of
drain pan to prevent ice blockage ● ● 7.555,-
Pressureless 300L domestic hot water tank EKHWP300B pressureless hygienic domestic hot
water tank with solar option ● ● 44.212,-
Pressureless 500L domestic hot water tank EKHWP500B pressureless hygienic domestic hot
water tank with solar option ● ● 50.615,-
Domestic hot water connection kit EKEPHT3H connection kit for combination with
EKHWP300B & EKHWP500B ● ● 7.836,-
> Rotex hybrid heat pump NEW!
26
▪ Flue gas system for Daikin Altherma hybrid boiler
For the combination with the Daikin Altherma hybrid gas condensing boiler, Daikin off ers a robust white concentric PP-fl ue
system. To safeguard an optimal operation of the system, Daikin advises to use this fl ue gas system in combination with it’s
Daikin Altherma hybrid heat pump system. The fl ue gas system is easy to set up in combination with the Daikin Altherma
hybrid gas condensing boiler.
In order to make the selection of you fl ue gas system easier for you, please visit http://fl uegas.daikin.eu/ and use the Daikin
fl ue gas selector tool.
C33 TOP
C33 FLAT C93 C33S
C13
C43
C43
> Rotex hybrid heat pump NEW!
27
C13, C33 concentric 60/100
Material name
Description Price CZK
EKFGP6837 Roof Terminal PP/GLV
60/100 AR460
1.892,-
EKFGS0518 Weather Slate Steep
Pb/GLV 60/100 18°-22°
2.747,-
EKFGS0519 Weather Slate Steep
Pb/GLV 60/100 23°-27°
2.747,-
EKFGP7910 Weather Slate Steep
PF 60/100 25°-45°
1.099,-
EKFGS0523 Weather Slate Steep
Pb/GLV 60/100 43°-47°
2.869,-
EKFGS0524 Weather Slate Steep
Pb/GLV 60/100 48°-52°
2.991,-
EKFGS0525 Weather Slate Steep
Pb/GLV 60/100 53°-57°
3.051,-
EKFGP1296 Weather Slate Flat Alu
60/100 0°-15°
1.709,-
EKFGP6940 Weather Slate Flat Alu
60/100
793,-
EKFGP2978 Kit horizontal PP/GLV
60/100
1.221,-
EKFGP2977 Kit horizontal low
profi le PP/GLV 60/100
1.526,-
EKFGP4651 Extension PP/GLV
60/100 x 500mm
793,-
EKFGP4652 Extension PP/GLV
60/100 x 1000mm
915,-
EKFGP4664 Elbow PP/GLV
60/100 30°
1.037,-
EKFGP4661 Elbow PP/GLV
60/100 45°
671,-
EKFGP4660 Elbow PP/GLV
60/100 90°
733,-
EKFGP4667 Meas. Tee with Inspection
Panel PP/GLV 60/100
2.563,-
EKFGP4631 Fixation / Wall Bracket
Dn.100
245,-
C13, C33 Concentric 80/125
Material name
Description Price CZK
EKFGP6864 Roof Terminal PP/GLV
80/125 AR300 Ral-9011
2.259,-
EKFGT6300 Weather Slate Steep
Pb/GLV 80/125 18°-22°
2.807,-
EKFGT6301 Weather Slate Steep
Pb/GLV 80/125 23°-27°
2.869,-
EKFGP7909 Weather Slate Steep PF
80/125 25°-45° Ral-9011
1.159,-
EKFGT6305 Weather Slate Steep
Pb/GLV 80/125 43°-47°
3.051,-
EKFGT6306 Weather Slate Steep
Pb/GLV 80/125 48°-52°
3.112,-
EKFGT6307 Weather Slate Steep
Pb/GLV 80/125 53°-57°
3.356,-
EKFGP1297 Weather Slate Flat
Alu 80/125 0°-15°
1.831,-
EKFGW5333 Weather Slate Flat
Alu 80/125
793,-
EKFGW6359 Wall Terminal Kit PP/
GLV 80/125
2.137,-
EKFGP4801 Extension PP/GLV
80/125 x 500mm
915,-
EKFGP4802 Extension PP/GLV
80/125 x 10000mm
977,-
EKFGP4814 Elbow PP/GLV
80/125 30°
1.037,-
EKFGP4811 Elbow PP/ALU
80/125 45°
793,-
EKFGP4810 Elbow PP/ALU
80/125 90°
793,-
EKFGP4820 Inspection Elbow Plus PP/
ALU 80/125 90° EPDM
2.014,-
EKFGP4481 Fixation / Wall Bracket
Dn.125
305,-
Multi Flex PP Dn.100 & Dn.130 C43 60/100 ONLY
Material name
Description Price CZK
EKFGP6368 Tee Flex 100 Boiler
Connectionset 1
4.760,-
EKFGP6354 Flex 100-60 +
Support Elbow
3.478,-
EKFGP6215 Tee Flex 130 Boiler
Connectionset 1
5.248,-
EKFGS0257 Flex 130-60 +
Support Elbow
3.906,-
EKFGP4678 Chimney Connection
60/100
1.221,-
EKFGP5461 Extension PP
60x500
245,-
Flex PP Dn.100 in combination with C43
Material name
Description Price CZK
EKFGP5497 Chimney Top PP
100 incl. Flue Pipe
2.502,-
EKFGP6316 Adapter Flex-Fixed
PP 100
1.159,-
EKFGP6337 Support Breaket
Top Inox Dn.100
549,-
EKFGP6346 Extension Flex PP
100 L=10 M
6.225,-
EKFGP6349 Extension Flex PP
100 L=15 M
9.337,-
EKFGP6347 Extension Flex PP
100 L=25 M
15.379,-
EKFGP6325 Connector Flex-
Flex PP 100
1.037,-
Flex PP Dn.130 in combination with C43
Material name
Description Price CZK
EKFGP5197 Chimney Top PP
130 incl. Flue Pipe
3.662,-
EKFGS0252 Adapter Flex-Fixed
PP 130
1.465,-
EKFGP6353 Support Breaket
Top Inox Dn.130
1.037,-
EKFGS0250 Extension Flex PP
130 L=30 M
20.140,-
EKFGP6366 Connector Flex-
Flex PP 130
1.526,-
Flex PP Dn.60-80 C93/C33s
Material name
Description Price CZK
EKFGP1856 Flex Kit PP Dn.60-
80
6.285,-
EKFGP4678 Chimney
Connection 60/100
1.221,-
EKFGP2520 Flex Kit PP Dn.80 7.140,-
EKFGP4828 Chimney
Connection 80/125
1.221,-
EKFGP6340 Extension Flex PP
80 L=10 M
5.126,-
EKFGP6344 Extension Flex PP
80 L=15 M
7.690,-
EKFGP6341 Extension Flex PP
80 L=25 M
11.779,-
EKFGP6342 Extension Flex PP
80 L=50 M
21.971,-
EKFGP6324 Connector Flex-
Flex PP 80
915,-
EKFGP6333 Spacer PP 80-100 305,-
> Rotex hybrid heat pump NEW!
28
Geothermal energy is a free source of energy for heating, and domestic
hot water. It delivers enormous cost savings in even
the coldest climates as the energy is at a relatively constant temperature
all year round. The compact design of the inside unit requires very
little space whilst, at the same time, making the system very
easy and quick to install. And, once commissioned, our easy,
user-friendly controls put the user in complete command.
For new build and replacement of boilers
> Daikin Altherma ground source heat pump
A new opportunity
for heating and domestic hot water.
NEW!
Daikin Altherma ground source heat pump horizontal Daikin Altherma ground source heat pump vertical
29
Cap
acit
y (k
W)
Ambient temperature (Ta) °C
Typical application:
• Location: Sweden
• Design temperature: -17°C
• Heat load: 13kW
• Heating off temperature: 16°C
Heat load line
Traditional ON/OFF unit
Daikin unit
BUH* = Back-up heater
High seasonal effi ciency thanks
to our inverter heat pump technologyThe Daikin inverter heat pump technology has been shown to provide an increase in seasonal efficiency of up to
20% when compared to traditional on/off ground source heat pumps.
• The brine, a water/anti-freeze mixture that operates as heat transfer medium between the ground and the heat pump,
is kept at a higher stable temperature
• Back up operation is reduced to a minimum
• High operating efficiencies of the compressor are reached at partial load operation, i.e. when no full capacity of
the unit is required.
• This results in reduced running costs and a faster return on investment.
When no full capacity is required of the system the compressor works in partial load. In partial load conditions, a traditional
on/off ground source heat pump sequently switches ON and OFF, whereby the brine temperature decreases down to
-4°C when the unit is operating. Daikin’s inverter technology results in a stable outgoing brine temperature of around 0°C.
This increased stability in brine temperature results in a higher and more constant evaporating temperature which leads to
higher operating effi ciencies.
Compared to a traditional On/Off unit, the requirement for support from the back up heater is much lower for the
Daikin Altherma ground source heat pump, thanks to the boosting eff ect of our inverter compressors, also this leads to
lower running costs.
Less back up heater operation thanks to the boosting of the inverter compressor
frequency
10
8
6
4
2
0
-2
-4
-6
-8
10
8
6
4
2
0
-2
-4
-6
-8
T (°C) T (°C)
Outgoing Brine Temperature (HP as reference)
Operation ON/OFF unit
Partial load condition - ON/OFF
Operation Daikin unit
Partial load condition - Inverter controlled
tt
Outgoing Brine Temperature (HP as reference)
ON ON
ON
OFFOFF
Case study
Higher brine temperatures during continuous
compressor operation, in partial load conditions
BUH*
Required heat output of
your home
> Daikin Altherma ground source heat pump NEW!
30
HEATING ONLY
INDOOR UNIT EGSQH10S18A9W
Heating
capacity
Min. kW 3,11 (1) / 2,47 (2)
Nom. kW 10,2 (1) / 9,29 (2)
Max. kW 13,0 (1) / 11,9 (2)
Power input Nom. kW 2,34 (1) / 2,82 (2)
COP 4,35 (1) / 3,29 (2)
Casing Colour White
Material Precoated sheet metal
Dimensions Unit HxWxD mm 1.732x600x728
Weight Unit kg 210
Tank Water volume l 180
Insulation Heat loss kWh/24h 1,36
Corrosion protection Anode
Operation
range
Installation
space
Min.~Max. °C 5~30
Brine side Min.~Max. °C -5~20
Heating Water side Min.~Max. °C 24~60 (heat pump) / 65 (heat pump + back up heater)
Domestic hot water Water side Min.~Max. °C 24~60 (heat pump) / 60 (back up heater)
Refrigerant Type R-410A
Charge kg 1,8
Sound power level Nom. dBA 46
Sound pressure level Nom. dBA 32
Power supply Name 9W
Phase 3~
Frequency Hz 50
Voltage V 400
Current Recommended fuses A 32
(1) EWB/LWB 0°C/-3°C - LWC 35°C (DT=5°C)
(2) EWB/LWB 0°C/-3°C - LWC 45°C (DT=5°C)
▪ Technical specifi cations
> Daikin Altherma ground source heat pump NEW!
31
> Daikin Altherma ground source heat pump
▪ Pricelist
The Daikin Altherma ground source heat pump system features a compact indoor unit with a fully integrated inverter heat
pump module and hot water tank. It needs to be combined with either a deep or shallow collector to draw energy from
the ground. It is easy to use too, with smart room temperature controls and an energy usage display, helping to reduce
energy consumption, while ensuring high levels of comfort.
DAIKIN Altherma ground source heat pump PRICE CZK
Daikin Altherma ground source heat pump
10kW
EGSQH10S18A9W Daikin Altherma ground source heat pump unit
incl. 180L DHW tank
224.079,-
Necessary accessories for a complete installation
(please only order one of the 7 controllers listed below)PRICE CZK
Controller EKRUCBL1 User interface with languages FR, NL, DE, IT 3.296,-
Controller EKRUCBL2 User interface with languages EN, SV, FI, NO 3.296,-
Controller EKRUCBL3 User interface with languages EN, ES, PT, EL 3.296,-
Controller EKRUCBL4 User interface with languages EN, RO, PL, TR 3.296,-
Controller EKRUCBL5 User interface with languages DE, SI, CZ, SK 3.296,-
Controller EKRUCBL6 User interface with languages EN, HR, HU, BG 3.296,-
Controller EKRUCBL7 User interface with languages EN, DA, RU, LT 3.296,-
Optional accessories PRICE CZK
Digital I/O PCB EKRP1HBA Remote alarm / operation status / … 4.144,-
Brine fi lling kit KGSFILL Kit to fi l land fl ush the brine circuit 4.699,-
Demand PCB EKRP1AHT Power consumption limitation with 4 digital inputs on hydrobox 4.158,-
Remote indoor sensor KRCS01-1 Temperature measurement remotely from user interface 2.432,-
PC cable EKPCCAB2 Cable to upload fi eld settings from PC to unit 7.555,-
Wired room thermostat EKRTWA Wired Digital Room Thermostat 3.938,-
Wireless room thermostat EKRTR Wireless Digital Room Thermostat 6.713,-
Thermostat external sensor EKRTETS Temperature measurement remotely from wireless
room thermostat (e.g. fl oor temperature)516,-
NEW!
32
One or more outdoor units
+ several indoor units
>> a modular system
Outdoor unit
Indoor installationDomestic hot
water tank
= +
Heating/Cooling
Indoor unit
Hot water
1 2Heating
3Cooling
Fit for purpose &Hot water on demand
The challenges for a fi tness center:
• Large exercise rooms with high levels
of heat being generated requiring
rigorous climate control throughout
the space
• High ‘on demand’ hot water usage
in the changing rooms
The solution:
• Daikin Altherma
Flex Type with its
modular and fl exible
approach.
Effi cient climate control for
residential applications
Commercial applications
Outdoor
1
2
3
> Daikin Altherma Flex Type
33
1 Commercial space /
1 ApartmentTotal building
20kW
22kW
40kW
45kWInstall separate
outdoor units to reach higher
capacities
(Separate system:
the outdoor units are not
connected to each other)
Note:
Heating capacities 7°C ambient
temperature, cooling capacities
35°C ambient temperature
6kW 9kW 11kW 14kW 16kW
5kW 8kW
3-IN-1 SYSTEM
Daikin Altherma Flex Type heats, cools and produces domestic hot water:
• Heating: leaving water temperatures up to 80° C
• Cooling: leaving water temperatures down to 5° C
• Hot water: tank temperatures up to 75° C
Thanks to the heat recovery function, the system can heat up the hot water tank up to 60°C with rejected heat from
cooling operation.
ENERGY EFFICIENT HEAT PUMP TECHNOLOGY
Compared to an oil boiler, this results in:
• Up to 36% less running costs*
• Up to 71% reduction of CO2 emissions*
• Up to 35% reduction in primary energy use*
* Data calculated taking in account Belgian conditions: SCOP of 3, average energy prices 2007-2010, CO2 emission factor for electricity production
MODULAR SYSTEM
One or more inverter-controlled outdoor heat pump units can provide heating, cooling and hot water. Outdoor units
between 23 and 45 kW extract the heat from the outdoor air, raise it to an intermediate temperature and transfer this heat
energy to the individual indoor units.
Indoor units are available in several classes (6, 9, 11 ,14 and 16 kW), ensuring optimum effi ciency. One outdoor unit can be
combined with up to ten indoor units. Multiple outdoor units can be installed for larger applications.
3P, 400V1P, 230V
> Daikin Altherma Flex Type
34
▪ Technical specifi cations
OUTDOOR UNIT EMRQ8A EMRQ10A EMRQ12A EMRQ14A EMRQ16A
Heating capacity Nom. kW 22,4 28 33,6 39,2 44,8
Cooling capacity Nom. kW 20 25 30 35 40
Dimensions Unit HxWxD mm 1.680x1.300x765
Weight Unit kg 331 339
Operation
range
Heating Min.~Max. °CWB -15~20
Domestic hot water Ambient Min.~Max. °CDB -15~35
Cooling Min.~Max. °CDB 10~43
Refrigerant Type R-410A
Piping
connections
Liquid OD mm 9,52 12,7
Suction OD mm 19,1 22,2 28,6
High and low pressure gas OD mm 15,9 19,1 22,2
Piping length OU - IU Max. m 100
System Equivalent m 120
Total piping length System Actual m 300
Sound power level Heating Nom. dBA 78 80 83 84
Sound pressure level Heating Nom. dBA 58 60 62 63
Power supply Phase/Voltage V 3~/380-415
Heating conditions: Ta = 7°CDB / 6°CWB, 100% connection ratio
Cooling conditions: Ta = 35°CDB, 100% connection ratio
* Capacity not guaranteed between -20°C and -15°C
> Daikin Altherma Flex Type
35
INDOOR UNIT EKHVMRD50A EKHVMRD80A EKHVMYD50A EKHVMYD80A
Casing Colour Metallic grey
Material Precoated sheet metal
Dimensions Unit HxWxD mm 705x600x695
Weight Unit kg 92 120
Operation
range
Heating Ambient Min.~Max. °C -15~20
Water side Min.~Max. °C 25~80
Cooling Ambient Min.~Max. °CDB -~- 10~43
Water side Min.~Max. °C -~- 5~20
Domestic hot
water
Ambient Min.~Max. °CDB -15~35
Water side Min.~Max. °C 45~75
Refrigerant Type R-134a
Charge kg 2
Sound pressure
level
Nom. dBA 40 1 / 43 2 42 1 / 43 2 40 1 / 43 2 42 1 / 43 2
Night quiet mode Level 1 dBA 38 1
Power supply Name V1
Phase 1~
Frequency Hz 50
Voltage V 220-240
Current Recommended fuses A 20
INDOOR UNIT EKHBRD011ACV1 EKHBRD014ACV1 EKHBRD016ACV1 EKHBRD011ACY1 EKHBRD014ACY1 EKHBRD016ACY1
Casing Colour Metallic grey
Material Precoated sheet metal
Dimensions Unit HxWxD mm 705x600x695
Weight Unit kg 144,25 147,25
Operation
range
Heating Ambient Min.~Max. °C -20~20
Water side Min.~Max. °C 25~80
Cooling Ambient Min.~Max. °CDB -~-
Water side Min.~Max. °C -~-
Domestic hot
water
Ambient Min.~Max. °CDB -20~35
Water side Min.~Max. °C 25~80
Refrigerant Type R-134a
Charge kg 3,2
Sound pressure
level
Nom. dBA 43 1 / 46 2 45 1 / 46 2 46 1 / 46 2 43 1 / 46 2 45 1 / 46 2 46 1 / 46 2
Night quiet mode Level 1 dBA 40 1 43 1 45 1 40 1 43 1 45 1
Power supply Name V1 Y1
Phase 1~ 3~
Frequency Hz 50
Voltage V 220-240 380-415
Current Recommended fuses A 25 16
(1) Sound levels are measured at: EW 55°C; LW 65°C (2) Sound levels are measured at: EW 70°C; LW 80°C
> Daikin Altherma Flex Type
36
Daikin Altherma Flex Type outdoor units.
Nominal heating capacity is measured at Ta 7°C and nominal cooling capacity at Ta 35°C with a 100% connection ratio. PRICE CZK
Daikin Altherma Flex outdoor unit 8HP EMRQ8A Outdoor unit with 22,4kW heating and 20kW
cooling capacity, power suppy 3~ 400V
256.069,-
Daikin Altherma Flex outdoor unit 10HP EMRQ10A Outdoor unit with 28 kW heating and 25kW cooling
capacity, power suppy 3~ 400V
327.514,-
Daikin Altherma Flex outdoor unit 12HP EMRQ12A Outdoor unit with 33,6kW heating and 30kW
cooling capacity, power suppy 3~ 400V
372.323,-
Daikin Altherma Flex outdoor unit 14HP EMRQ14A Outdoor unit with 39,2kW heating and 35kW
cooling capacity, power suppy 3~ 400V
388.972,-
Daikin Altherma Flex outdoor unit 16HP EMRQ16A Outdoor unit with 44,8kW heating and 40kW
cooling capacity, power suppy 3~ 400V
478.315,-
Daikin Altherma Flex Type indoor units (fl oorstanding) for heating& cooling and heating only applications.
All basic necessary hydraulic components included. PRICE CZK
Daikin Altherma Flex 5kW indoor unit
heating only
EKHVMRD50A Power Supply 1~ 230V 129.521,-
Daikin Altherma Flex 5kW indoor unit
heating & cooling
EKHVMYD50A Power Supply 1~ 230V 143.646,-
Daikin Altherma Flex 8kW indoor unit
heating
EKHVMRD80A Power Supply 1~ 230V 133.781,-
Daikin Altherma Flex 8kW indoor unit
heating & cooling
EKHVMYD80A Power Supply 1~ 230V 147.853,-
Daikin Altherma Flex 11kW indoor unit
heating only
EKHBRD011ACV1 Power Supply 1~ 230V 127.626,-
Daikin Altherma Flex 14kW indoor unit
heating only
EKHBRD014ACV1 Power Supply 1~ 230V 132.500,-
Daikin Altherma Flex 16kW indoor unit
heating only
EKHBRD016ACV1 Power Supply 1~ 230V 136.574,-
Daikin Altherma Flex 11kW indoor unit
heating only
EKHBRD011ACY1 Power Supply 3~400V 131.235,-
Daikin Altherma Flex 14kW indoor unit
heating only
EKHBRD014ACY1 Power Supply 3~400V 136.429,-
Daikin Altherma Flex 16kW indoor unit
heating only
EKHBRD016ACY1 Power Supply 3~400V 141.177,-
▪ Pricelist
Daikin Altherma Flex Type for residential and commercial applications is a
3-in-1 system off ering heating, domestic hot water and cooling all-in-one
highly effi cient.
Daikin Altherma Flex Type achieves a typical seasonal COP of 3 in the
moderate Western and central European climate. Further more, Daikin
Altherma Flex Type is a modular system. Depending from your project one
or more outdoor units can be combined with up to ten indoor units per
outdoor unit.
> Daikin Altherma Flex Type
37
Options & accessoriesApplicable for:
11-16kWPRICE CZK
Wired room thermostat EKRTWA Wired Digital Room Thermostat ● 3.938,-
Wireless room thermostat EKRTR Wireless Digital Room Thermostat ● 6.713,-
Digital I/O PCB EKRP1HBA Remote alarm / operation status ● 4.144,-
Modbus Interface RTD-W monitoring and control ModBus interface ● 10.538,-
Sequencing Controller EKCC-W master/slave control kit that can control and monitor up
to 16 hydroboxes, connected through RTD-W ● 28.562,-
Thermostat external sensor EKRTETS Temperature measurement remotely from wireless
room thermostat (e.g. fl oor temperature) ● 516,-
Demand PCB for connection of room
thermostat or backup heater
EKRP1AHT required when EKRTWA or EKRTR is used as a room
thermostat or if a backup heater is installed ● 4.158,-
Remote user interface EKRUAHTB can be used as a second user interface (master/slave)
besides the one delivered with the indoor unit ● 6.177,-
In-line backup heater 1~, 230V, 6kW EKBUHA6V3 Electrical backup heater for space heating support only ● 18.198,-
In-line backup heater 3~, 400V, 6kW EKBUHA6W1 Electrical backup heater for space heating support only ● 18.198,-
Option kit for standalone tank EKFMAHTB Kit required when EKHTS tanks are to be placed next to the indoor unit ● 15.427,-
Optionional billing kit EKMBIL1 Option kit for billing of tank mounted on indoor unit ● 4.308,-
Central drainpan kit for outdoor unit KWC25C450 drain pan kit to collect the condensate after defrost operation ● 36.601,-
Domestic hot water connection kit for
EKHWP300B
EKEPHT3H connection kit for HT in combination with EKHWP300B ● 7.836,-
Domestic hot water connection kit for
EKHWP500B
EKEPHT5H connection kit for HT in combination with EKHWP500B ● 14.066,-
Domestic hot water tanksApplicable for:
11-16kWPRICE CZK
Stainless steel domestic hot water tank
200L
EKHTS200AC Domestic hot water tank 200L, Dimensions HxBxT = 1335x600x695,
height increases to 2010 if mounted on top of indoor unit ● 41.962,-
Stainless steel domestic hot water tank
260L
EKHTS260AC Domestic hot water tank 200L, Dimensions HxBxT = 1610x600x695,
height increases to 2285 if mounted on top of indoor unit ● 47.397,-
Pressureless 300L domestic hot water tank EKHWP300B pressureless hygienic domestic hot water tank with solar option ● 44.212,-
Pressureless 500L domestic hot water tank EKHWP500B pressureless hygienic domestic hot water tank with solar option ● 50.615,-
Refrigerant branch kits for outdoor units 3 pipes 3 pipes
Outdoor unit capacity type (HP) imperial metric imperial metric
8 + 10 KHRQ23M29T9 KHRQM23M29T KHRQ22M29T9 KHRQM22M29T
Price CZK 5.046,- 5.046,- 4.542,- 4.542,-
12 ~ 16 KHRQ23M64T KHRQM23M64T KHRQ22M64T KHRQM22M64T
Price CZK 8.223,- 8.223,- 5.492,- 5.492,-
Refnet joints for indoor units 3 pipes 3 pipes
Indoor unit capacity index imperial metric imperial metric
< 200 KHRQ23M20T KHRQM23M20T KHRQ22M20T KHRQM22M20T
Price CZK 4.424,- 4.424,- 3.384,- 3.384,-
200 ≤ x < 290 KHRQ23M29T9 KHRQM23M29T KHRQ22M29T9 KHRQM22M29T
Price CZK 5.046,- 5.046,- 4.542,- 4.542,-
290 ≤ x < 520 KHRQ23M64T KHRQM23M64T KHRQ22M64T KHRQM22M64T
Price CZK 8.223,- 8.223,- 5.492,- 5.492,-
Refnet headers for indoor units 3 pipes 3 pipes
Indoor unit capacity index imperial metric imperial metric
<200 and 200 ≤ x < 290 KHRQ23M29H KHRQM23M29H KHRQ22M29H KHRQM22M29H
Price CZK 8.966,- 8.966,- 6.381,- 6.381,-
290 ≤ x < 520 KHRQ23M64H KHRQM23M64H KHRQ22M64H KHRQM22M64H
Price CZK 10.923,- 10.923,- 7.896,- 7.896,-
> Daikin Altherma Flex Type
38
The heat pump convector unit can provide both heating and cooling if required, since the heat
pump convector is more than just a fan coil unit.
The heat pump convector also has a very low noise level.
When combining under fl oor heating and fan coil units, the
low leaving water temperatures, important for effi ciency,
are adequate for under fl oor heating, but the fan coil units
then need to be oversized in order to emit the proper levels
of heat at these low water temperatures. The heat pump
convector solves this problem.
The heat pump convector is able to emit the required
levels of heat at low leaving water temperatures, while
retaining a modest size.
Instead of the leaving water circuit being switched on
and off via a thermostat in a single master room, each
heat pump convector can be directly wired to the Daikin
Altherma indoor unit, the system’s intelligence centre. This
allows all rooms to have heat when required, regardless of
the state of the other rooms.
The heat pump convector saves on running costs thanks to the improved effi ciency by approximately
25% compared to a heating system that combines under-
fl oor heating and regular fan coil units. The heat pump
convector can easily replace existing heat emitters, thanks
to its plug and play installation.
Heat pump convector
> Heat pump convector
39
INDOOR UNITS FWXV20A FWXV15A
Heating capacity Total capacity Nom. kW 2,0 1,5
Cooling capacity Total capacity Nom. kW 1,7 1,2
Sensible
capacity
Nom. kW 1,4 0,98
Power input Heating Nom. kW 0,015 0,013
Cooling Nom. kW 0,015 0,013
Dimensions Unit H x W x D mm 600/700/210
Weight Unit kg 15
Piping connections Drain/OD/Inlet/Outlet mm/
inch18/G 1/2/G 1/2
Sound pressure
level
Heating Nom. dBA 29 19
Cooling Nom. dBA 29 19
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
(1) Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K.
(2) Heating: room temperature 20°CDB and entering water temperature 45°C, water temperature drop 5K.
▪ Technical specifi cations
Daikin Altherma Heat pump Convector PRICE CZK
Daikin Altherma
Heat pump Convector 1,5kW
FWXV15A Heat pump convector with 1,5kW* heating capacity
and 1,2kW** and 0,3kW*** cooling capacity 19.149,-
Daikin Altherma
Heat pump Convector 2,0kW
FWXV20A Heat pump convector with 2,0kW* heating capacity
and 1,7kW** and 0,4kW*** cooling capacity 20.701,-
Options & Accessories PRICE CZK
2 way valve kit EKVKHPC needs to be used in all cooling and high temperature applications, where
watertemperatures of below 18°C and/or 60°C or above can occur 2.651,-
* water inlet temperature 45°C and water outlet temperature 40°C, room temperature 20°C DB - medium fanspeed
**water inlet temperature 7°C and water outlet temperature 12°C, room temperature 27°C DB / 19°C WB - medium fanspeed
***water inlet temperature 18°C and water outlet temperature 23°C, room temperature 27°C DB / 19°C WB - medium fanspeed
▪ Pricelist
Daikin‘s Heat pump convector with interlink function is another heating
innovation coming from the Daikin internal product development. Perfectly
suitable for low temperature applications, e.g. in combination with underfl oor
heating, the Heat pump convector is a stylish, compact, intelligent and very
silent solution for quick heating or cooling of residential areas.
> Heat pump convector
40
Solar kit
The solar kit provides the transfer of solar heat to the Daikin
Altherma hot water tank via an external heat exchanger.
In contrast to tanks with two heat exchangers, this system
allows the entire content of the tank to be effi ciently heated
with solar heat and, if necessary, with heat pump energy.
Solar collector
The high-effi ciency collectors transfer all the short-wave
solar radiation into heat as a result of their highly selective
coating. The collectors can be mounted on the roof tiles.
Pressurised system
The system is fi lled with heat transfer fl uid with the correct
amount of of antifreeze to avoid freezing in winter. The
whole system is then pressurised and sealed.
Pressureless system
The system is fi lled with pure water which is transferred
from the pressureless energy storage tank, whenever the
sun is out. If no sun is out and thus no energy is needed, the
water is drained back into the pressureless energy storage
tank.
What do you need?
• Solar collector
• Plumbing network and solar pump station
• Supply tank: standard Daikin Altherma domestic hot
water tank
• Solar kit
• Re-heater (Daikin Altherma heat pump unit which also
provides the home with heating)
Solar connection
> Daikin solar system
1- Solar collector
2- Solar pump station
3- Solar kit available in combination with stand alone
(EKHWS - EKHWE) domestic hot water tank
3
2
1
Daikin off ers two types of solar
systems in combination with
their heat pumps.
41
Solar collectors
Averaged over an entire year, the sun
delivers half of the energy we need to bring
our domestic hot water up to the desired
temperature. High-effi ciency collectors
with highly selective coating transfer all the
short-wave solar radiation into heat. The
collectors can be mounted on roof tiles.
Operation
The solar collectors are only fi lled with
water when suffi cient heat is provided by
the sun. In this case, both pumps in the
control and pump unit switch on briefl y
and fi ll the collectors with storage tank
water. After fi lling, which takes less than
a minute, one of the pumps switches off
and water circulation is maintained by the
remaining pump.
1. Cold water connection
2. Hot water connection
3. Storage tank charging flow
4. Storage tank charging return flow
5. Heating support flow
6. Heating support return
7. Drain Back solar flow
8. Storage tank (polypropylene double
walled jacket with PUR hard foam heat
insulation)
9. Mount for solar R3 controller / handle
10. Safety overflow connection
11. Drain-back solar - return flow / Filling
and draining connection for storage
tank water
12. Fill level indicator
13. Connection for booster heater
14. Electric immersion booster heater
15. Sensor pocket for tank temperature
sensor
16. Domestic hot water heat exchanger
17. Charging heat exchanger
18. Inlet from solar collector
19. Pressure-free storage tank water
20. Solar zone
21. Hot water zone
> Daikin solar system
EKHWP: domestic hot water tank
The domestic hot water tank has two sections: The upper, always hot, section – the active water zone – and the
lower, colder section – the solar zone.
1. The active water is heated in the upper section of the storage tank. The high temperature of this zone
ensures that sufficient hot water is always available.
2. Solar collectors work more efficiently when colder water flows through the solar collectors. Therefore, the water
that is fed directly to the solar collectors in solar operation is stored in the solar zone.
1413
126
5 71
24
3
1010
8
18
9
2417
16
9
11
1519
20
21
23
Solar collector
Indoor unit and
domestic hot water tank
42
SOLAR CONNECTION EKSOLHWAV1
Dimensions Unit H x W x D mm 770x305x270
Weight Unit kg 8
Operation
range
Ambient
temperature
Min,~Max, °C1~35
Sound pressure
level
Nom, dBA27
Thermal
performance
Zero loss collector effi ciency η0
%-
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240
Power supply intake Indoor unit
ACCESSORY EKSR3PA
Mounting On wall
Dimensions Unit H x W x D mm 332x230x145
Thermal
performance
Zero loss collector effi ciency η0
%-
Control Type Digital temperature diff erence controller with plain text display
Power consumption W 2
Sensor Solar panel temperature sensor Pt1000
Storage tank sensor PTC
Return fl ow sensor PTC
Feed temperature and fl ow sensor Voltage signal (3,5V DC)
Power supply Frequency/Voltage Hz/V 50/230
SOLAR COLLECTOR EKSV26P EKSH26P EKSV21P
Dimensions Unit H x W x D mm 2,000x1,300x85 1,300x2,000x85 2,000x1,006x85
Weight Unit kg 42 35
Volume l 1,7 2,1 1,3
Surface Outer m² 2,601 2,01
Aperture m² 2,364 1,795
Absorber m² 2,354 1,791
Coating Micro-therm (absorption max,96%, Emission ca, 5% +/-2%)
Absorber Harp-shaped copper pipe register with laser-welded highly selective coated aluminium plate
Glazing Single pane safety glass, transmission +/- 92%
Allowed roof
angle
Min,~Max, °C15~80
Operating
pressure
Max, bar6
Stand still
temperature
Max, °C200
Thermal
performance
Zero loss collector effi ciency η0
% 78,7 78,3
Heat loss coeffi cient a1 W/m²,K 4,270 4,25
Temperature dependence of
the heat loss coeffi cient a2
W/
m²,K²0,0070 0,0057
Thermal capacity kJ/K 6,5 -
Incident
angle
modifi er
AM at 50°
0,94 -
Installed position Vertical Horizontal Vertical
SOLAR CONNECTION EKSRPS3B
Dimensions Unit H x W x D mm -
Control Type Digital temperature diff erence controller with plain text display
Power consumption W -
Mounting On side of tank
Sensor Solar panel temperature sensor Pt1000
Storage tank sensor PTC
Return fl ow sensor PTC
Feed temperature and fl ow sensor Voltage signal (3,5V DC)
> Daikin solar system
▪ Technical specifi cations
43
> Daikin solar system
▪ Pricelist
For Daikin Altherma LT, HT and Flex units a pressurised and pressureless solar system is available. Main components are the standard Daikin tanks as well as pressureless hygienic domestic hot water tanks, combined with Daikin‘s solar kits and controllers and solar panels for on-roof, in-roof and fl at roof installations.
Material Description Price per unit CZK
Solar Panel EKSV26P Vertical big solar panel 2000 x 1300 mm21.053,-
EKSH26P Horizontal big solar panel 2000 x 1300 mm21.689,-
EKSV21P Vertical small solar panel 2000 x 1006 mm17.896,-
Daikin hot water tanks & accessories EKHWS* Stainless steel tank see page 9
EKHWE* Enameled tank see page 9
EKSOLHW Solar heat exchanger kit 23.134,-
EKHWP300B Hygienic Domestic hot water tank, 300l 44.212,-
EKHWP500B Hygienic Domestic hot water tank, 500l 50.615,-
165070 Set of 2 gravity brakes 456,-
164102-RTX FLG FLG - fl ow regulating valve with fl ow rate indicator 2.279,-
156015 VTA32 Thermostatic antiscald mixing valve 2.888,-
156016 1“ screw connection set for VTA32 1.140,-
162070 MAGS12 Solar Expansion Vessel 12L 4.388,-
162050 MAGS25 Solar Expansion Vessel 25L 5.320,-
162051-RTX MAGS35 Solar Expansion Vessel 35L 8.209,-
Solar Controlers & Pump Stations EKSRPS3B Solar controller for drain back applications 22.918,-
EKSR3PA Solar controller for pressurized applications 10.214,-
EKSRDS1A Solar pump station 15.155,-
164116 Flow sensor for a pressurized system 4.694,-
Solar priority PCB + cable EKRP1HBA PCB kit to disable hot water mode through HP during solar water heating 4.144,-
164110-RTX BSKK Solar priority cable / connection cable to disable heatpump 684,-
Solar panel installation accessories 164732 CON15 Pressureless Connection piping between solar panel & pump station: 15m 5.244,-
164733 CON20 Pressureless Connection piping between solar panel & pump station: 20m 6.232,-
164261-RTX CONX25 Pressureless elongation pipe 2,5m including couplings 3.268,-
164262-RTX CONX50 Pressureless elongation pipe 5m including couplings 3.725,-
164263 CONX100 Pressureless elongation pipe 10m including couplings 4.864,-
164264 CONXV80 Pressureless elongation for inlet pipe 8m 4.181,-
162073 CON15P16 Pressure solar pipe DN16 - 15m 18.849,-
162071 CONXP16 Connectors DN16 456,-
162074 CON15P20 Pressure solar pipe DN20 - 15m 23.333,-
162072 CONXP20 Connectors DN20 684,-
162075 CONCP16 Pressure solar connection set DN 16 2.351,-
162076 CONCP20 Pressure solar connection set DN 20 3.384,-
EKSRCRP Connection kit, incl. red roof tile 8.164,-
EKSRCAP Connection kit, incl. anthracite roof tile 8.164,-
EKSRCP Connection kit ON ROOF 5.906,-
162037-RTX RCIP Mounting kit IN-ROOF 5.169,-
162038-RTX RCFP Mounting kit FLAT ROOF 9.880,-
164709 CONFE Additional roof breakthrough for opposite side connection 3.041,-
162016-RTX FIXVBP Connection kit between 2 solar panels 2.128,-
162035-RTX CONRVP Connection kit between 2 rows of collectors 2.736,-
162045 CONLCP Connection kit between 2 rows of collectors 4.181,-
162066 FIXMP100 Mounting rail for V21 1.520,-
162067 FIXMP130 Mounting rail for V26P 1.672,-
162068 FIXMP200 Mounting rail for H26P 2.279,-
164245 TS Suporting shell for pressureless connection pipe 304,-
162036-RTX FIXADP Variable height mounting set for on-roof mounting suitable for roof tiles 3.725,-
162069 FIXADD Standard mounting set for on-roof mounting suitable for roof tiles 746,-
164723 FIXADS Mounting set for on-roof mounting suitable for fl at tiles e.g. shingles 2.203,-
164703-RTX FIXWD Mounting set for on-roof mounting suitable for corrugated plates 2.128,-
164704-RTX FIXBD Mounting set for on-roof mounting suitable for metal roofs 2.509,-
162017 IBV21P Basic IN ROOF installation kit for 2 EKSV21P 18.849,-
162018 IEV21P Extension IN ROOF installation kit for 1 additional EKSV21P 8.437,-
162019 IBV26P Basic IN ROOF installation kit for 2 EKSV26P 20.142,-
162020 IEV26P Extension IN ROOF installation kit for 1 additional EKSV26P 8.816,-
164616-RTX FIXIES IN ROOF covering slate complementing kit 4.940,-
162058 FBV26P Basic FLAT ROOF support frame for 2 EKSV26P 22.649,-
162059 FEV26P Extension FLAT ROOF support frame for additional EKSV26P 9.045,-
162060 FBH26P Basic FLAT ROOF support frame for 1 EKSH26P 10.717,-
162061 FEH26P Extension FLAT ROOF support frame for additional EKSH26P 6.992,-
162029-RTX FIXLP Release tool 304,-
162052-RTX GFL 20l ready to use glycol Tmin
= -28°C 3.573,-
44
▪ Drain back combination tables
▪ Additional items drain back in function of installation
> Daikin solar system
EKSV21P Drain back
# of panels 2 3 4 5
Material On
roof
In
roof
On
roof
In
roof
On
roof
In
roof
On
roof
In
roof
EKSV21P 2 2 3 3 4 4 5 5
FIXVBP 1 1 2 2 3 3 4 4
FIXMP100 2 2 3 3 4 4 5 5
FIXADP
2 0 3 0 4 0 5 0FIXADS
FIXWD
FIXDB
IBV21P 0 1 0 1 0 1 0 1
IEV21P 0 0 0 1 0 2 0 3
EKHWP***B 1 1 1 1 1 1 1 1
EKSRPS3B 1 1 1 1 1 1 1 1
EKRP1HBA 1 1 1 1 1 1 1 1
BSKK 1 1 1 1 1 1 1 1
FLG 1* 1* 1* 1* 1* 1* 1* 1*
TS 1 1 1 1 1 1 1 1
CON15 1 1 1 1 1 1 1 1
EKSRCAP/EKSRCRP 1 0 1 0 1 0 1 0
RCIP 0 1 0 1 0 1 0 1
* : optional (recommended)
EKSV26P Drain back
# of panels 2 3 4 5
Material On
roof
In
roof
Flat
roof
On
roof
In
roof
Flat
roof
On
roof
In
roof
Flat
roof
On
roof
In
roof
Flat
Roof
EKSV26P 2 2 2 3 3 3 4 4 4 5 5 5
FIXVBP 1 1 1 2 2 2 3 3 3 4 4 4
FIXMP130 2 2 2 3 3 3 4 4 4 5 5 5
FIXADP
2 0 0 3 0 0 4 0 0 5 0 0FIXADS
FIXWD
FIXDB
IBV26P 0 1 0 0 1 0 0 1 0 0 1 0
IEV26P 0 0 0 0 1 0 0 2 0 0 3 0
FBV26P 0 0 1 0 0 1 0 0 1 0 0 1
FEV26P 0 0 0 0 0 1 0 0 2 0 0 3
EKHWP***B 1 1 1 1 1 1 1 1 1 1 1 1
EKSRPS3B 1 1 1 1 1 1 1 1 1 1 1 1
EKRP1HBA 1 1 1 1 1 1 1 1 1 1 1 1
BSKK 1 1 1 1 1 1 1 1 1 1 1 1
FLG 1* 1* 1* 1* 1* 1* 1* 1* 1* 1* 1* 1*
TS 1 1 1 1 1 1 1 1 1 1 1 1
CON15 1 1 1 1 1 1 1 1 1 1 1 1
EKSRCAP/EKSRCRP 1 0 0 1 0 0 1 0 0 1 0 0
RCIP 0 1 0 0 1 0 0 1 0 0 1 0
RCFP 0 0 1 0 0 1 0 0 1 0 0 1
* : optional (recommended)
EKSH26P Drain back
# of panels 1 2 3 4 5
Material On
roof
Flat
roof
On
roof
Flat
roof
On
roof
Flat
roof
On
roof
Flat
roof
On
roof
Flat
roof
EKSH21P 1 1 2 2 3 3 4 4 5 5
FIXVBP 0 0 1 1 2 2 3 3 4 4
FIXMP200 1 1 2 2 3 3 4 4 5 5
FIXADP
1 0 2 0 3 0 4 0 5 0FIXADS
FIXWD
FIXDB
FBH26P 0 1 0 1 0 1 0 1 0 1
FEH26P 0 0 0 1 0 2 0 3 0 4
EKHWP***B 1 1 1 1 1 1 1 1 1 1
EKSRPS3B 1 1 1 1 1 1 1 1 1 1
EKRP1HBA 1 1 1 1 1 1 1 1 1 1
BSKK 1 1 1 1 1 1 1 1 1 1
FLG 1* 1* 1* 1* 1* 1* 1* 1* 1* 1*
TS 1 1 1 1 1 1 1 1 1 1
CON15 1 1 1 1 1 1 1 1 1 1
EKSRCAP/EKSRCRP 1 0 1 0 1 0 1 0 1 0
RCFP 0 1 0 1 0 1 0 1 0 1
* : optional (recommended)
Material Description Required quantity
165070 Gravity brakes 1 set per tank heat exchanger adviced if piping from heat exchanger is not making downward bend at the tank
CONX25
Elongation sets Depending on required elongationCONX100
CONX50
CONXV80 Elongation pipe with couplings for inlet 8 m Only required if rooftransit of outlet pipe collector can not be located next to outlet connection of solar collector
CONRVP Connection pipe between solar panel rows Number of rows - 1; Remove 1 FIXVBP per CONRVP
45
> Daikin solar system
▪ Pressurised combination tables
EKSV21P Pressurised
# of panels 2 3 4
Material On
roof
In
roof
On
roof
In
roof
On
roof
In
roof
EKSV21P 2 2 3 3 4 4
FIXVBP 1 1 2 2 3 3
FIXMP100 2 2 3 3 4 4
FIXADD 6 0 10 0 12 0 standard roof tiles
FIXADP
2 0 3 0 4 0 other roof typesFIXWD
FIXDB
IBV21P 0 1 0 1 0 1
IEV21P 0 0 0 1 0 2
EKHWS / EKHWE 1 1 1 1 1 1
EKSOLHWAV1 1 1 1 1 1 1
EKSRDS1A 1 1 1 1 1 1
164116 1 1 1 1 1 1
EKSR3PA 1 1 1 1 1 1
FLG 1* 1* 1* 1* 1* 1*
CON15P16 1 1 1 1 0 0
CONCP16 1 1 1 1 0 0
CON15P20 0 0 0 0 1 1
CONCP20 0 0 0 0 1 1
MAGS12 1 1 0 0 0 0
MAGS25 0 0 1 1 0 0
MAGS35 0 0 0 0 1 1
EKSRCP 1 1 1 1 1 1
GFL Depending on system volume
* : optional (recommended)
EKSV26P Pressurised
# of panels 1 2 3
Material On
roof
In
roof
Flat
roof
On
roof
In
roof
Flat
roof
On
roof
In
roof
Flat
roof
EKSV26P 1 2 2 2 3 3 3
FIXVBP 0 1 1 1 2 2 2
FIXMP130 1 2 2 2 3 3 3
FIXADD 4 6 10 standard roof tiles
FIXADP
1 2 0 0 3 0 0other roof
typesFIXWD
FIXDB
IBV26P 0 0 1 0 0 1 0
IEV26P 0 0 0 0 0 1 0
FBV26P 0 0 0 1 0 0 1
FEV26P 0 0 0 0 0 0 1
EKHWS / EKHWE 1 1 1 1 1 1 1
EKSOLHWAV1 1 1 1 1 1 1 1
EKSRDS1A 1 1 1 1 1 1 1
164116 1 1 1 1 1 1 1
EKSR3PA 1 1 1 1 1 1 1
FLG 1* 1* 1* 1* 1* 1* 1*
CON15P16 1 1 1 1 1 1 1
CONCP16 1 1 1 1 1 1 1
MAGS12 1 1 1 1 0 0 0
MAGS25 0 0 0 0 1 1 1
EKSRCP 1 1 1 1 1 1 1
GFL Depending on system volume
* : optional (recommended)
EKSH26P Pressurised
# of panels 1 2 3
Material On
roof
Flat
roof
On
roof
Flat
roof
On
roof
Flat
roof
EKSH21P 1 1 2 2 3 3
FIXVBP 0 0 1 1 2 2
FIXMP200 1 1 2 2 3 3
FIXADD 4 0 6 0 10 0 standard roof tiles
FIXADP
1 0 2 0 3 0 other roof typesFIXWD
FIXDB
FBH26P 0 1 0 1 0 1
FEH26P 0 0 0 1 0 2
EKHWS / EKHWE 1 1 1 1 1 1
EKSOLHWAV1 1 1 1 1 1 1
EKSRDS1A 1 1 1 1 1 1
164116 1 1 1 1 1 1
EKSR3PA 1 1 1 1 1 1
FLG 1* 1* 1* 1* 1* 1*
CON15P16 1 1 1 1 1 1
CONCP16 1 1 1 1 1 1
MAGS25 1 1 1 1 1 1
EKSRCP 1 1 1 1 1 1
GFL Depending on system volume
* : optional (recommended)
▪ Additional items pressurised in function of installation
Material Description Required quantity
CONLCP Connection pipe between solar panel rows Number of rows - 1; Remove 1 FIXVBP per CONLCP
CONXP16 Connection between 2 CON15P16 Additional CON15P16 needed
CONXP20 Connection between 2 CON15P20 Additional CON15P20 needed
47
> Commercial terms and conditions
Campus 21, Europaring F12/402 · A-2345 Brunn am Gebirge, Austria
phone +43 2236 32557, fax +43 2236 32557-900, offi [email protected], www.daikin-ce.com
The Daikin Commercial terms and conditions are also available in the internet at http://www.daikin-ce.com
I. GENERAL
Our deliveries and services are exclusively subject to the following terms and conditions of sale and delivery, even
if the customer provides otherwise. The ordering party’s counter-confi rmations in reliance on his commercial
terms and conditions or his terms and conditions of purchase apply only if they are consistent with these terms
and conditions of delivery. Acceptance of the goods is in any event deemed to constitute an acknowledgment of
our terms and conditions of sale and delivery. Any deviating modifi cations and amendments require our express
consent and must be made in writing to be legally valid. Our commercial terms and conditions can be found at
www.daikin-ce.com.
II. OFFER
Our off ers are without engagement and non-binding. Any information about dimensions, weights, technical data,
quantities and delivery times is non-binding.
III. PLACING OF AN ORDER, CHANGE OF THE DELIVERABLE
1 . Orders must be placed in writing (by letter, fax or email). We are deemed to have accepted an order not until
after we have confi rmed in writing or actually executed that order. Any arrangement and agreement reached
verbally and by phone must be confi rmed in writing.
2. We reserve the right to rescind the contract even after having accepted an order if information we have
obtained about the customer’s liquidity in the meantime suggests that the customer will not be able to pay for
the entire or for part of the order.
3. Having accepted an order, we also reserve the right to change and improve the service or deliverable, e.g. in
respect of its type and design, to the extent the customer can be reasonably expected to accept such changes
and improvements in consideration of our interests (e.g. delivery of an equivalent or more sophisticated
device). Such changes and improvements are deemed approved in advance.
4. The customer’s cancellation or change of an entire or of part of an order requires our written consent
and entitles us to charge the customer - in addition to the services already provided and costs accrued
- a (cancellation) fee equal to 20 % of the order value and at least € 250. For certain product
groups (e.g. multiple scroll, screw chiller), separate cancellation rules apply which can be found at
www.daikin-ce.com.
IV. PRICES AND TERMS OF PAYMENT
1. Prices are based on the price list, as amended from time to time, which is usually issued once a year. We reserve
the right to change prices also during a year.
2. Prices are understood to be net prices without any taxes, duties or charges in the quoted currency, including
packaging, ex our forwarding warehouse, unless otherwise indicated. We will not take back packaging and
packing material.
3. We will not accept any objections to invoices which are received more than two weeks after receipt of an
invoice. Unless otherwise indicated, invoices are due net 30 days from the invoice date; the payment date is
the date on which a payment is received by us. In case of late payment, we will charge default interest at a rate
of 12% p.a. In case of default, we may also demand all costs related to the collection of our claim, including,
without limitation, dunning and collection charges.
4. If payment by instalments has been agreed, the maturity date will be accelerated if the customer is in default
in respect of only one instalment.
5. We may make deliveries dependent on advance payment.
6. The customer may not withhold or set off payments in reliance on warranty or other claims.
V. DELIVERY TIME
1. Indicated delivery times are non-binding and reference times only, although we endeavour to meet indicated
deadlines. The customer has no right to insist on compliance with a certain delivery time. As a consequence,
delays in delivery will not entail any claims for damages and do not entitle the customer to rescind the contract.
The same holds true if delivery deadlines are not met due to force majeure, strike or other events outside our
control.
2. We will not accept penalty claims asserted by the customer under any circumstances.
3. Partial deliveries are permitted.
4. If the ordering party is in arrears on an earlier delivery, Daikin may withhold deliveries pending payment of the
earlier delivery and is not required to pay to the ordering party any damages in this respect.
VI. ACCEPTANCE OF DELIVERIES, TRANSFER OF RISK, DELAYED ACCEPTANCE
1. Unless otherwise agreed, deliveries are made CIP (Incoterms 2010) to the named destination
2. In principle, delivery CIP covers only minimum transport insurance. Additional transport insurance will be
purchased only if explicitly requested by customer and subject to a separate agreement and at the customer’s
cost and expense.
3. The customer must immediately check deliverables received by him or directly by his customers for any
transport damage, and he must record any damage to the packaging or the device in the delivery note and
shall refuse delivery towards the forwarding agent. If the customer fi nds out only later that goods are damaged,
the customer shall report any such damage to us, immediately, in no case later than three working days after
delivery; otherwise, any insurance claim may expire.
4. If the customer accepts goods with delay, we - notwithstanding our other rights - may charge the goods as
delivered or may otherwise dispose of them @ setting a time limit. If we otherwise dispose of the goods, the
delivery time will recommence on the day we receive the customer’s written request calling for delivery of
the goods.
5. We may charge the customer for any costs incurred due to late acceptance, including, without limitation, any
storage costs.
VII. RESERVATION OF TITLE
1. We will retain title to goods delivered pending full payment of all claims arising from our business relationship
with the customer, even if the purchase price for specifi cally designated claims was paid. If our conditional
goods are processed, we will acquire title to the new item without consideration. If the goods delivered by us
are mixed, processed or combined with other items, the customer hereby assigns to us in proportion of the
value of our invoices an ownership or co-ownership right of the combined or new item, both in respect of the
interim and the fi nal products.
2. The customer may resell goods delivered by us and the items created by processing, mixing or combining
these only in the ordinary course of business. The customer hereby assigns to us any claims arising from such
resale or from any other legal ground toward third parties, including, ancillary rights, in order to secure our -
future - claims that may arise from our business relationship. The customer must record the assignment of these
claims in his books not later than when the goods are resold.
3. Before having paid the purchase price of an item, the customer may resell that item only if he simultaneously
informs the second buyer (end customer) that the resale proceeds have previously been assigned.
4. The customer may collect the assigned claims as long as he fulfi ls his payment obligations towards us according
to the terms of the contract. The customer may not otherwise dispose of the conditional goods (e.g.: transfer
of property by way of security, pledging).
5. The customer must immediately inform us of any attachment or other impairment of the conditional goods
and/or the assigned claims and explain to the third party that we have retained title to those goods. Any related
cost will be borne by the customer.
VIII. WARRANTY AND LIABILITY
A. Unless otherwise agreed and to the exclusion of any further claims, we are liable for any defects and the absence
of warranted qualities as follows:
1. Unless otherwise indicated below, the warranty period is 36 months of the delivery date (delivery to the
forwarding agent). This does not aff ect the applicability of Section 924 of the Austrian Civil Code.
2. The customer may assert a warranty claim only if the equipment is both installed and put into operation
by Daikin or a company trained by Daikin according to the Daikin installation instructions and regularly
maintained according to the Daikin service notes. Refrigerating machines featuring screw-type compressors
include a 12-month warranty claim only if the machine was put into operation by Daikin itself. In case of
products designated “J&E Hall International for Daikin” the customer may assert an 18-month warranty claim.
For “Rotex” branded products generally a 24-month warranty period is valid except for following variations: 10
years for underfl oor heating pipes and system plates, VA-piping and variosafe oil storage tanks. 5 years for solar
panels, variosystem and highcube oil tanks and variocistern rainwater tanks. 3 years for HPSU heat pump solar
unit and hot water storage tanks HYC, SCS and SC.
3. In a warranty event, we undertake, at our election, to replace or repair the defective goods or components. The
customer may not assert other warranty or guarantee claims whatsoever. Labour cost, travel times or other
costs will not be reimbursed.
4. No warranty and/or liability is accepted, unless the customer reports visible defects by giving written notice
within 3 working days of delivery and other defects without delay after these have been discovered.
5. In addition to paragraphs 2 and 4, no warranty and/or liability is accepted for defects that have been caused by
inadequate or improper use or treatment, failure to observe operating conditions or maintenance guideless,
excessive use or inadequate operating facilities or substitute materials.
6. Unless we are granted the required time and opportunity to take all necessary warranty measures, we are
released from any warranty claims and damages. If the customer continues to use defective goods, we warrant
and/or are liable only for the original defect. We will not reimburse any cost of repairs which are carried out
without our express prior consent. We disclaim any liability for the consequences of such repairs.
7. The warranty period for spare parts and other improvements is 6 months of delivery (delivery to the forwarding
agent).
8. If a defect is remedied, the warranty period will not recommence for the replaced or repaired components.
9. We may refuse to remedy defects as long as the customer is in default with his payment obligations. The
customer has no right to withhold payments, even if he gave justifi ed notice of defects.
10. If third-party products are delivered and installed, warranty is restricted to assigning the warranty claims we
may assert against the supplier of the third-party product. The customer may not assert any other warranty
claims and may particularly not claim a price reduction.
B. We are liable for damage only if we demonstrably acted with intent or gross negligence. We disclaim any
liability for slight negligence. We are particularly not liable for consequential damage (e.g. idle times due to wrong
deliveries) and fi nancial loss, lost profi t, unachieved savings, loss of interest and any damage suff ered from third-
party claims against the customer, unless the foregoing is attributable to our intent or gross negligence. If damage
is attributable to the defective condition of goods delivered by us, we are liable only to the extent the producer
or upstream supplier is liable to us. Our liability does in any case not exceed the invoice value of the incriminated
goods.
IX. RETURNED GOODS
1. Goods can be returned and exchanged only upon our express and written consent. We accept returned goods
only with a minimum net value of € 100,00 and a maximum net value of € 50.000,00 and only provided that
those goods are not damaged, have not been used, are in original packaging and are fi t for resale. In particular,
returns of already installed units (including chillers) and returns of any made to order units as well as spare
parts are not permitted.
2. The customer shall complete the “Request for Goods Return”-form (available at the DENV Extranet,
http:\\extranet.daikineurope.com) and send it to us to the fax number or email address provided by us within
10 calendar days after delivery, otherwise we will not accept the return.
3. Goods must be returned freight paid at the risk of customer to the destination indicated by us.
4. In every case of a return, a maximum of 80% of the net price charged by us to the customer will
be credited. All standard returns will be subject to a restocking / administration charge of 20 % of the net price.
5. All returns will be inspected by us. If goods are returned wrongly (i.e. not in compliance with paragraph 1.
above), we may refuse the returns and have them returned back to the customer at the customer’s risk and
costs. Alternatively, we may charge a higher restocking / administration fee than the above mentioned 20%.
6. Any credit notes whatsoever will exclusively be set off against future deliveries.
X. PLACE OF JURISDICTION, APPLICABLE LAW
1. All disputes arising from or in connection with this Agreement shall be exclusively referred to the courts in
Vienna.
2. All contracts concluded by us and all disputes arising in connection with those contracts shall be governed
by and construed in accordance with Austrian law without giving eff ect to its confl ict of law rules and the UN
Sales Convention.
XI. SEVERABILITY
Should any term of these commercial terms and conditions or of the contract concluded between us and the
customer be invalid or ineff ective, this shall not aff ect the remaining terms hereof or thereof. Invalid terms shall be
replaced by lawful terms which closest refl ect the parties’ intent.
The present publication is drawn up by way of information only and does not
constitute an offer binding upon Daikin Europe N.V./Daikin Central Europe
HandelsGmbH. Daikin Europe N.V./Daikin Central Europe HandelsGmbH has
compiled the content of this leaflet to the best of its knowledge. No express
or implied warranty is given for the completeness, accuracy, reliability or fitness
for particular purpose of its content and the products and services presented
therein. Specifications are subject to change without prior notice. Daikin Europe
N.V./Daikin Central Europe HandelsGmbH explicitly rejects any liability for any
direct or indirect damage, in the broadest sense, arising from or related to the
use and/or interpretation of this leaflet. All content is copyrighted by Daikin
Europe N.V.
DA
CE
He
atin
g P
rice
list
20
15
Ve
rsio
n 1
• C
op
yrig
ht
Dai
kin
We
re
serv
e t
he
rig
ht
for
pri
nti
ng
err
ors
an
d m
od
el c
han
ge
s.
DAIKIN AIRCONDITIONING CENTRAL EUROPE HandelsgmbH
campus 21, Europaring F12/402, A – 2345 Brunn am Gebirge
Tel.: +43 / 22 36 / 3 25 57, Fax: +43 / 22 36 / 3 25 57-900
e-mail: offi [email protected], www.daikin-ce.com
Daikin Europe N.V. participates in the Eurovent
Certifi cation programme for Air conditioners (AC),
Liquid Chilling Packages (LCP), Air handling units
(AHU) and Fan coil units (FCU), Check ongoing validity
of certifi cate online: www.eurovent-certifi cation.com
or using: www.certifl ash.com
Daikin Products are distributed by:
COP in heat pump operation: 5.04
Heating and domestic hot
water
Most economical mode to operate
Up to 35% effi ciency increase compared to condensing boiler
Gas condensing boiler of33 kW
Hybrid technology
The naturalcombination
Rotex hybrid heat pump