TECHNICAL CATALOGUE Save energy! Reduce your costs! Take care of the environment! HEAT RECOVERY UNITS VENTILATION • AIR CONDITIONING • HEATING

Upload: others

Post on 23-Sep-2020

11 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HEAT RECOVERY UNITS...Heat recovery units evB aL 05.01-01 EVB AL – HEAT RECOVERY UNITS Description • Units for secondary use of energy of the exhaust air in ventilation and air-conditioning

TECHNICAL CATALOGUE

Save energy!

Reduce your costs!

Take care of the environment!

HEAT RECOVERY UNITS

VENTILATION • AIR CONDITIONING • HEATING

Pernik

Blagoevgrad

Petrich

Smolian

Plovdiv Haskovo

Kazanlak

Gabrovo

Sliven

Office of Tangra

Distributor of Tangra

Head office

Office Varna

Office Burgas6, Transportna Str.

Tel.: (00359 56) 861 200e-mail: [email protected]

Tel.: (00359 52) 611 767e-mail: [email protected]

West Industrial Rangebehind printing house Varna - East

Shumen

Ruse

Gorna Oriahovitsa

Stara Zagora

Vratsa

Sofia

Varna

Burgas

174, Europa Blvd.1331 Sofia, Bulgariawww.tangra.bgTel.: (00359 2) 925 05 99; 925 06 10Tel.: (00359 2) 927 58 13; 972 71 80Fax: (00359 2) 925 05 57e-mail: [email protected]

Page 2: HEAT RECOVERY UNITS...Heat recovery units evB aL 05.01-01 EVB AL – HEAT RECOVERY UNITS Description • Units for secondary use of energy of the exhaust air in ventilation and air-conditioning
Page 3: HEAT RECOVERY UNITS...Heat recovery units evB aL 05.01-01 EVB AL – HEAT RECOVERY UNITS Description • Units for secondary use of energy of the exhaust air in ventilation and air-conditioning

We reserve the right to introduce alternations both in design and technical data without prior notice, due to continued product development. www.tangra.bg

3

The air we breathe is important for our life!

One can live 3 weeks without food, 3 days without water, 3 minutes without air!

People in industrialized countries spend indoor, on average about 90% of the year. Modern buildings and systems do not allow natural ventilation. This is a major precondition for creation of mechanical ventilation.

The fresh air must be heated in winter and chilled in summer, and this is related with significant energy costs. There is a preliminary trend for growing of the price of energy resources for the last 10 years:

Energy consumption leads to environmental pollution and exhausting of resources of the planet. It is our duty to protect it for future generation.

Quickly return on investments using heat recovery systems:

Human health and productivity are closely connected with the air quality. Our children need fresh air even more than us – it could help to avoid illnesses and allergies.

The data shown are not universal. These parameters are valid for the following conditions:- Bulgaria, Sofia;- Indoor temperature 22oC;- Air flow – 3000m3/h;- Installation working time – 10 of 24h.- Installation life time – 10 years;- Energy price – 0.1 Euro/kWh;- 8% annual maintenance costs;- Energy price growth – 12% per year;- The initial expenses are average;

Your lost money!

Heat recovery units

Page 4: HEAT RECOVERY UNITS...Heat recovery units evB aL 05.01-01 EVB AL – HEAT RECOVERY UNITS Description • Units for secondary use of energy of the exhaust air in ventilation and air-conditioning

www.tangra.bg We reserve the right to introduce alternations both in design and technical data without prior notice, due to continued product development.

4

Heat recovery systems are the proper technical and economically acceptable solution:

Applications of heat recovery units:

Ventilation and air-conditioning systems, which provide fresh air supply in:- Office and residential buildings;- Hotels, restaurants, cafes, nightclubs;- Sports halls, gyms and swimming pools;- Hospitals, schools, laboratories;- Cinemas, theaters, concert halls;- Food industries – bakeries;- Technological systems;- Industrial ventilation.

0

1000

2000

3000

4000

5000

6000

7000

8000

9000

10000

-15 -10 -5 0 5 10

Q ,kWh

text , оС

ENERGY CONSUMPTION PER YEAR, kWh

AHU - A

0

1000

2000

3000

4000

5000

6000

7000

8000

9000

10000

-15 -10 -5 0 5 10

Q ,kWh

text , оС

ENERGY CONSUMPTION PER YEAR, kWh

AHU - A

AHU - B

0

1000

2000

3000

4000

5000

6000

7000

8000

9000

10000

-15 -10 -5 0 5 10

Q ,kWh

text , оС

ENERGY CONSUMPTION PER YEAR, kWh

AHU - A

AHU - C

0

1000

2000

3000

4000

5000

6000

7000

8000

9000

10000

-15 -10 -5 0 5 10

Q ,kWh

text , оС

ENERGY CONSUMPTION PER YEAR, kWh

AHU - A

AHU - D

0

1000

2000

3000

4000

5000

6000

7000

8000

9000

10000

-15 -10 -5 0 5 10

Q ,kWh

text , оС

ENERGY CONSUMPTION PER YEAR, kWh

AHU - A

AHU - E

AHU - A

REC AHU - B

AHU - C REC REC

AHU - D

AHU - E REC

System without recuperation

E=0%

System with plate heat exchanger

E=45 – 58%

System with high-efficiency plate heat

exchanger

E=65 – 70%

System with rotary heat exchanger

E=70 – 83%

E - % percentage of recovered energy

Heat recovery units

Page 5: HEAT RECOVERY UNITS...Heat recovery units evB aL 05.01-01 EVB AL – HEAT RECOVERY UNITS Description • Units for secondary use of energy of the exhaust air in ventilation and air-conditioning

We reserve the right to introduce alternations both in design and technical data without prior notice, due to continued product development. www.tangra.bg

5

Heat recovery units 05.01-01evB aL

EVB AL – HEAT RECOVERY UNITS

Description

• Units for secondary use of energy of the exhaust air inventilation and air-conditioning systems.

• Operationtemperaturesfrom-20°Cto+50°C.• Designed toworkwith clean air in non-aggressive and

explosion-proof environment

Construction

• Supporting construction,made by anodized aluminumprofiles.

• Thermo and sound insulated panels, powder coatedRAL7035

- Internal insulation – Firex 10 mm, fire resistance – class: 0-BS 476 Part 6; class – 1 BS 476 Part7;

-Sandwichpanels–25mmwithXPSinsulationclassM1or fiberglass class M0;

• Crossflowaluminumplateheatexchangerwithefficien-cy up to 55%;

• Doubleinletdirectdrivecentrifugalfans–230V,50Hz,IP20(higherprotection–onrequest);

• AirfiltersclassG4–EN779:2002;• Rectangularorroundductconnector;• Draintraywith½”connection;• Configurationallowseasilymodifyingpositionofthefil-

ters, fans and duct connectors;• Servicedoors–fromthebottomandfromtheside;• By-passwithmultipleleafdamper;• Heating/coolingcoil–onrequest;• Hangingsupportorbasicsteps–onrequest;• Roofpanelforoutdoorinstallation–onrequest.• Controlandmanagementsystems-seesection7

Page 6: HEAT RECOVERY UNITS...Heat recovery units evB aL 05.01-01 EVB AL – HEAT RECOVERY UNITS Description • Units for secondary use of energy of the exhaust air in ventilation and air-conditioning

www.tangra.bg We reserve the right to introduce alternations both in design and technical data without prior notice, due to continued product development.

6

05.01-02 Heat recovery unitsevB aL

Overall and joined dimensions

EVB AL, H – Horizontal installation

Model Max. air flow [m3/h]

В [mm]

Н [mm]

L [mm]

Hmax [mm]

C [mm]

D [mm]

Ø [mm]

G [mm]

I [mm]

ЕVB PP-04-H 500 800 280 800 320 215 150 200 215 150ЕVB AL-06-H 700 1000 350 1000 390 225 180 250 225 180ЕVB AL-10-H 1000 1000 420 1300 460 235 210 280 300 250ЕVB AL-20-H 2200 1060 480 1500 520 300 260 315 300 300ЕVB AL-30-H 3000 1200 580 1600 620 265 290 355 400 300ЕVB AL-35-H 3500 1200 680 1600 720 335 290 355 400 400ЕVB AL-45-H 4500 1300 900 2000 940 335 290 355 400 400

EVB AL, V – Vertical installation

Model Max. air flow [m3/h]

В [mm]

Н [mm]

L [mm]

Bmax [mm]

C [mm]

D [mm]

Ø [mm]

G [mm]

I [mm]

K [mm]

ЕVB PP-04-V 500 280 800 800 320 150 150 200 215 150 45ЕVB AL-06-V 700 350 1000 1000 390 180 225 250 225 180 50ЕVB AL-10-V 1000 420 1000 1300 460 210 235 280 250 300 85ЕVB AL-20-V 2200 510 1060 1500 550 260 300 315 300 300 105ЕVB AL-30–V 3000 580 1200 1600 620 290 265 355 300 400 90ЕVB AL-35-V 3500 680 1200 1600 620 290 335 355 400 400 140ЕVB AL-45-V 4500 900 1300 2000 940 290 335 355 400 400 250

Page 7: HEAT RECOVERY UNITS...Heat recovery units evB aL 05.01-01 EVB AL – HEAT RECOVERY UNITS Description • Units for secondary use of energy of the exhaust air in ventilation and air-conditioning

We reserve the right to introduce alternations both in design and technical data without prior notice, due to continued product development. www.tangra.bg

7

Heat recovery units 05.01-03evB aL

Overall and joined dimensions

EVB AL-BS (with by pass), H – Horizontal installation

Model В [mm] Н [mm] L [mm] Hmax [mm] C [mm] D [mm] Ø [mm] G [mm] I [mm]

ЕVB AL-06-BS 1050 450 1200 520 225 180 250 225 180

ЕVB AL-10-BS 1050 520 1300 590 235 210 280 300 250

ЕVB AL-20-BS 1060 650 1500 720 300 260 315 300 300

ЕVB AL-30-BS 1200 750 1600 820 265 290 355 400 300

ЕVB AL-35-BS 1300 850 1600 920 335 290 355 400 400

ЕVB AL-45-BS 1300 1150 2000 1220 335 290 355 400 400

• By-passwithinternalmultipleleafdamper;• Manualcontrol-onrequest;• “Belimo”ON-OFFactuator–standardversion

Page 8: HEAT RECOVERY UNITS...Heat recovery units evB aL 05.01-01 EVB AL – HEAT RECOVERY UNITS Description • Units for secondary use of energy of the exhaust air in ventilation and air-conditioning

www.tangra.bg We reserve the right to introduce alternations both in design and technical data without prior notice, due to continued product development.

8

Overall and joined dimensions

EVB AL-HBS (heating water coil and by pass), H – Horizontal installation

Model В [mm] Н [mm] L [mm] Hmax [mm] C [mm] D [mm] Ø [mm] G [mm] I [mm] d [mm]

ЕVB AL-06-HBS 1050 450 1600 520 225 180 250 225 180 ½”

ЕVB AL-10-HBS 1050 520 1600 590 235 210 280 300 250 ¾”

ЕVB AL-20-HBS 1200 650 1900 720 300 260 315 300 300 1”

ЕVB AL-30-HBS 1300 750 1900 820 265 290 355 400 300 1¼”

ЕVB AL-35-HBS 1300 850 1900 920 335 290 355 400 400 1¼”

ЕVB AL-45-HBS 1450 1150 2500 1220 335 290 355 400 400 1¼”

• By-passwithinternalmultipleleafdamper;• Manualcontrol-onrequest;• “Belimo”ON-OFFactuator–standardversion• Tworowswatercoil–Cu/Al;• Fourrowswatercoil(cooling)-onrequest.

05.01-04 Heat recovery unitsevB aL

Page 9: HEAT RECOVERY UNITS...Heat recovery units evB aL 05.01-01 EVB AL – HEAT RECOVERY UNITS Description • Units for secondary use of energy of the exhaust air in ventilation and air-conditioning

We reserve the right to introduce alternations both in design and technical data without prior notice, due to continued product development. www.tangra.bg

9

Heat recovery units 05.01-05evB aL

Technical characteristics

Exte

rnal

pre

ssur

e [P

a]

Airflow[m3/h]

EVB PP-04

Model Fan Nominal power [W] Nominal current [A]

EVB-P-04 CBM/2-133/190-185W 2x185 0.8

Airflow[m3/h]

Exte

rnal

pre

ssur

e [P

a]

EVB AL-06

Model Fan Nominal power [W] Nominal current [A]

ЕBV AL-06 СBM/2-146/180 2х220 1.01

Page 10: HEAT RECOVERY UNITS...Heat recovery units evB aL 05.01-01 EVB AL – HEAT RECOVERY UNITS Description • Units for secondary use of energy of the exhaust air in ventilation and air-conditioning

www.tangra.bg We reserve the right to introduce alternations both in design and technical data without prior notice, due to continued product development.

10

05.01-06 Heat recovery unitsevB aL

Technical characteristicsEx

tern

al p

ress

ure

[Pa]

Airflow[m3/h]

EVB AL-10

Model Fan Nominal power [W] Nominal current [A]

ЕBV AL-10 СBM/4-180/180 2х147 1.5

ЕBV AL-10/3V СBM/4-180/180-V 2х147 1.33

Airflow[m3/h]

Exte

rnal

pre

ssur

e [P

a]

EVB AL-20

Model Fan Nominal power [W] Nominal current [A]

ЕBV AL-20 СBM/4-240/240 2х370 4.2

ЕBV AL-20/3V СBM/4-240/240-3V 2х370 3.8

Page 11: HEAT RECOVERY UNITS...Heat recovery units evB aL 05.01-01 EVB AL – HEAT RECOVERY UNITS Description • Units for secondary use of energy of the exhaust air in ventilation and air-conditioning

We reserve the right to introduce alternations both in design and technical data without prior notice, due to continued product development. www.tangra.bg

11

Heat recovery units 05.01-07evB aL

Technical characteristics

Exte

rnal

pre

ssur

e [P

a]

Airflow[m3/h]

EVB AL-30

Model Fan Nominal power [W] Nominal current [A]

ЕBV AL-30 СBM/4-270/200 2х370 4.0

ЕBV AL-30/3V СBM/4-270/200-3V 2х370 3.0

Airflow[m3/h]

Exte

rnal

pre

ssur

e [P

a]

EVB AL-35

Model Fan Nominal power [W] Nominal current [A]

ЕBV AL-35 СBM/4-270/270 2х550 6.2

Page 12: HEAT RECOVERY UNITS...Heat recovery units evB aL 05.01-01 EVB AL – HEAT RECOVERY UNITS Description • Units for secondary use of energy of the exhaust air in ventilation and air-conditioning

www.tangra.bg We reserve the right to introduce alternations both in design and technical data without prior notice, due to continued product development.

12

05.01-08 Heat recovery unitsevB aL

Sound pressure level on frequency bands [dB]

Model Hz 63 125 250 500 1000 2000 4000 8000

EVB PP-04Inlet 49 54 51 50 48 52 50 41

Outlet 47 55 56 65 68 70 66 63Rad. 40 45 40 41 44 43 41 34

EVB AL-06Inlet 50 55 52 51 49 53 50 43

Outlet 48 56 58 66 70 71 67 65Rad. 41 46 42 41 45 45 42 35

EVB AL-10Inlet 46 51 56 61 56 51 47 40

Outlet 46 53 58 65 68 67 66 58Rad. 47 48 49 50 38 39 34 27

EVB AL-20Inlet 49 56 64 66 63 56 54 43

Outlet 48 58 67 70 75 74 71 62Rad. 48 52 56 55 52 46 41 33

EVB AL-30Inlet 49 56 63 66 64 57 56 45

Outlet 48 57 65 71 75 74 72 63Rad. 48 52 55 54 52 45 42 32

EVB AL-35Inlet 52 61 66 67 64 57 55 45

Outlet 51 63 69 71 75 75 72 64Rad. 51 58 61 56 53 47 42 35

EVB AL-45Inlet 52 61 66 67 64 57 55 45

Outlet 51 63 69 71 75 75 72 64Rad. 45 53 55 50 47 42 38 31

Note: Measured in free field conditions at a distance 1,5 m.

Своб

оден

нап

ор [P

a]

Дебитнавъздуха[m3/h]

Note: Thedottedcurvereferstoheatrecoveryunitwithheatexchanger800/600-2R

EVB AL-45

Model Fan Nominal power [W] Nominal current [A]

ЕBV AL– 45 СBM-10/104P,3V 2х750 7,8

Technical characteristics

Page 13: HEAT RECOVERY UNITS...Heat recovery units evB aL 05.01-01 EVB AL – HEAT RECOVERY UNITS Description • Units for secondary use of energy of the exhaust air in ventilation and air-conditioning

We reserve the right to introduce alternations both in design and technical data without prior notice, due to continued product development. www.tangra.bg

13

Accessories

• Externalhighefficiencyfilter–F7,ΔPmax = 80Pa• Soundattenuators• Externalelectricheater• Roofforoutdoorinstallation• Flexibleductconnectors• 3-wayvalveforwatercoil

• Freezeprotection• Pressureswitch• 3-speedswitch• Hangingsupports• Basicsteps• Frameforoutdoorinstallation• Controlandmanagementsystems-seesection7

EVB AL - 30 /3V -HBS

BS – By pass; HBS – heating coil and by pass

3-speed fan

Model

Heat recovery unit

Order designation

- Main parameters

- Optional parameters

Heat recovery units 05.01-09evB aL

Standard configuration

Configuration A and C as standard. Modification B and D-oncustomer’srequest.

A B

C D

EVB AL, H – Horizontal installation

EVB AL, V – Vertical installation

Page 14: HEAT RECOVERY UNITS...Heat recovery units evB aL 05.01-01 EVB AL – HEAT RECOVERY UNITS Description • Units for secondary use of energy of the exhaust air in ventilation and air-conditioning

www.tangra.bg We reserve the right to introduce alternations both in design and technical data without prior notice, due to continued product development.

14

Page 15: HEAT RECOVERY UNITS...Heat recovery units evB aL 05.01-01 EVB AL – HEAT RECOVERY UNITS Description • Units for secondary use of energy of the exhaust air in ventilation and air-conditioning
Page 16: HEAT RECOVERY UNITS...Heat recovery units evB aL 05.01-01 EVB AL – HEAT RECOVERY UNITS Description • Units for secondary use of energy of the exhaust air in ventilation and air-conditioning

TECHNICAL CATALOGUE

Save energy!

Reduce your costs!

Take care of the environment!

HEAT RECOVERY UNITS

VENTILATION • AIR CONDITIONING • HEATING

Pernik

Blagoevgrad

Petrich

Smolian

Plovdiv Haskovo

Kazanlak

Gabrovo

Sliven

Office of Tangra

Distributor of Tangra

Head office

Office Varna

Office Burgas6, Transportna Str.

Tel.: (00359 56) 861 200e-mail: [email protected]

Tel.: (00359 52) 611 767e-mail: [email protected]

West Industrial Rangebehind printing house Varna - East

Shumen

Ruse

Gorna Oriahovitsa

Stara Zagora

Vratsa

Sofia

Varna

Burgas

174, Europa Blvd.1331 Sofia, Bulgariawww.tangra.bgTel.: (00359 2) 925 05 99; 925 06 10Tel.: (00359 2) 927 58 13; 972 71 80Fax: (00359 2) 925 05 57e-mail: [email protected]