heat pump - nanodomi · tube in tube titanium heat exchanger/tube in shell ... new times swimming...

16
ISO14001 CCC CE ISO9001 C-Tick CB CB SAA ROHS t c u d ro P en Gre c. In h c te ly o IP e B c A Head Office: Yangwu First Industrial District, Dalingshan Town, Dongguan City, Guangdong Province, China TEL: +86-769-82783328 FAX: +86-769-85621399 Guangzhou branch: TEL: +86-20-38891913 FAX: +86-20-38891611 Website: www.xsdxny.com Email: bill@xsdxny.com Room 2501-2506,Vili international building, No.167 Linhexi Road, Tianhe District, Guangzhou,China Dongguan New Times New Energy Science & Technology Co., Ltd. HEAT PUMP

Upload: duongthien

Post on 27-May-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HEAT PUMP - Nanodomi · Tube in tube titanium heat exchanger/tube in shell ... New times swimming pool heat pump applies titanium coil exchanger and heat pump technology

Partner of 2010 Shanghai Expo Sole Designated Heat pump supplier for ZED PAVILIONPartner of 2010 Shanghai Expo Sole Designated Heat pump supplier for ZED PAVILION

ISO14001CCCCE ISO9001C-TickCB

CBSAAROHS

tcud

ro P

enGre

c.Inhcte

lyoIP

eBc

A

Head Office: Yangwu First Industrial District, Dalingshan Town, Dongguan City,

Guangdong Province, China

TEL: +86-769-82783328 FAX: +86-769-85621399

Guangzhou branch:

TEL: +86-20-38891913 FAX: +86-20-38891611

Website: www.xsdxny.com

Email: [email protected]

Room 2501-2506,Vili international building, No.167 Linhexi Road,

Tianhe District, Guangzhou,China

Dongguan New Times New Energy Science & Technology Co., Ltd.

HEAT PUMP

Page 2: HEAT PUMP - Nanodomi · Tube in tube titanium heat exchanger/tube in shell ... New times swimming pool heat pump applies titanium coil exchanger and heat pump technology

ontentscAbout New Times

Pool & spa heaters

Spa heat pumps

Residential pool heat pumps

Commercial pool heat pumps

Domestic hot water units

All in one heat pumps (A series)

All in one heat pumps (B series)

Split heat pumps

Monobloc heat pumps

Commercial hot water units

Commercial cycle heating heat pumps

Commercial direct heating heat pumps

High temperature heat pumps

Room heating units

Low temperature heat pumps (EVI system)

Air cooled chiller

Multifunctional heat pumps

...............................................

.......................................................

.............................................

...........................................

...........................................

..........................................

......................................................

.................................................

....................................

....................................

...........................................

................................

.......................................................

...............................................

01

03

05

07

09

11

13

15

17

19

21

23

25

27

Page 3: HEAT PUMP - Nanodomi · Tube in tube titanium heat exchanger/tube in shell ... New times swimming pool heat pump applies titanium coil exchanger and heat pump technology

Established in 1994, Dongguan New

Times New Energy Science &

Technology Co., Ltd always persists in

ph i losophy o f “Energy sav ing

Technology, People oriented”. We

specialize in researching, producing

and marketing heat pump water

heaters. New Times has a total

manufacturing base of more than

60,000 m2.

As one of the leading professional

manufacturers of Heat Pumps in China

with more than 20 years experience in

this field, New Times has a full

production line for heat pump. On the

whole, New Times found a R&D center

and has more than 30 well-qualified

technology elites. We have our own

mold workshop, metal plate workshop,

water tank workshop and product

testing line. Our water tank annual

output can reach 100,000 sets,

manufacturing ability of metal plate is

50,000 sets one year.

We control strictly quality for guarantee eligible products. And we have

passed ISO9001:2000 International Quality System, ISO14001

International Environmental Management System authentication,

International Standard Production Enterprise Certification and Energy-

saving Products Certification. In addition, products of New Times are

approved with CCC, CE, CB,C-Tick, SAA, EN14511 etc. In view of good

quality, New Times products are designated by the People’s Liberation

Army in CISM Village at the 29th session of Olympic Games and 2010

Shanghai World EXPO ZED Pavilion as the sole air source hot water

facilities supplier. New Times is also designated by the China National

Standards Committee as member to participate in drafting out the

National Standard for Air Source Heat Pump Water Heater industry.

Products manufactured by New Times have been exported to UK,

France, Italy, Middle East, Australia,and Africa etc. Our development

vision will keep on persisting in principle of practicability, pioneer and

innovation, and research & develop more efficient, energy-saving, eco-

friendly and safer products to make great contribution to Chinese &

worldwide energy saving and emission reduction, security and

environmental cause.

Compared to counterparts, our product advantages include safety,

energy-saving, eco-friendly, practical, durable, easy to operate and

install, stable running, low noise, intelligent defrosting etc.

About New Times

01 02

Page 4: HEAT PUMP - Nanodomi · Tube in tube titanium heat exchanger/tube in shell ... New times swimming pool heat pump applies titanium coil exchanger and heat pump technology

03 04

pa Heat Pumps S

Specifications

Testing condition: Heating working condition: Outdoor DB/WB temp = 24℃/19℃, 62.5%RH, inlet water temp = 26℃.

Model

Heating Capacity

COP

Max Water Outlet Temperature

Rated Input Power

Rated Input Current

Max Input Power

Max Input Current

Power Supply

Compressor Type

Number of Compressors

Heat Exchanger

Throttling device

Fan type

Fan Direction

Number of Fans

Fan Air Flow Volume

Fan Power Input

Fan Rotation Speed

Ambient Temperature

Refrigerant

Water circulation flow

Water circulation pressure drop

Noise in 1 meter distance

Piping Diameter

Cabinet

Discharge Pressure

Suction Pressure

Product Dimension

kW

BTU/h

----

kW

A

kW

A

V/PH/Hz

m /h3

W

RPM

m /h3

kPa

dB (A)

mm

Mpa

Mpa

mm

HLRC6-SP HLR 8-SP C HLR 10-SP C HLR 12-SPC

5.8 7.6 10.3 12.1

19800 25900 35100 41300

5.47 5.35 5.48 5.43

1.06

5.07

1.45

6.94

50

1.42

6.79

1.96

9.38

1.88

9

2.64

12.6

2.23

10.07

3.15

15.1

220-240V/1N~/50Hz

Rotary

1 1 1 1

Titanium tube in PPR shell

Capillary

Low noise high efficiency axial type

Horizontal

1 1 1 1

2000

20

850

2000

20

850

2600

40

850

2600

40

850

-7℃-43℃

R410A

1.7-2.5

30

≤48

Rc1-1/2"

2.2-3.3

30

≤48

Rc1-1/2"

2.9-4.4

30

≤54

Rc1-1/2"

3.5-5.2

30

≤54

Rc1-1/2"

Steel with powder coated

2.2-3.8

0.8-1.6

930/350/550 930/350/550 1010/350/620 1010/350/620

Net Weight Kg 45 50 60 66

Features:

*

*

*

*

*

*

*

*

Titanium tube in PPR shell heat exchanger

Rotary compressor

Intelligent defrosting

Compact configuration

Horizontal fan discharge

Easy installation

Low noise & vibration

High temperature hot water outlet

The application of R410A refrigerant which will not do harm to the

ozone layer and thus is more environmently-friendly. Titanium heat

exchanger which is corrosion resisting makes the unit with a longer

service life. This series also integrates with many intelligent functions.

This series is specially suitable for SPA.

Page 5: HEAT PUMP - Nanodomi · Tube in tube titanium heat exchanger/tube in shell ... New times swimming pool heat pump applies titanium coil exchanger and heat pump technology

05 06

Specifications

Residential Pool Heat Pumps

Features:*

*

*

*

*

Scroll compressor

R407c refrigerant

Intelligent defrosting

Compact structure

Easy installation & operation;

1. Heating working condition: Outdoor DB/WB temp: 24℃/19℃,62.5%RH, inlet water temp:26℃.

2. Cooling working condition: Outdoor DB/WB temp: 43℃/37℃,68%RH, inlet water temp:32℃.

Note:

9.8

33400

4.76

6.2

21200

2.82

13.5

46100

4.33

8.8

30000

2.67

21.3

72700

4.95

14.7

50200

2.67

Rated Input Current (Heating/ Cooling)

kW

BTU/h

----

kW

BTU/h

----

V/PH/HZ

kW

A

kW

A

m /h3

W

RPM

dB (A)

mm

Mpa

Mpa

MPa

3m /h

Kg

4.5

15400

5

3

10200

2.86

7

23900

4.83

4.5

15400

2.73

HLRC8-YC HLRC9-YC HLRC15-YCUnits HLRC3-YC HLRC5-YCModel

Heating Capacity

COP

Cooling Capacity

EER

Max Water Outlet Temperature

Power Supply

Rated Input Power (Heating/Cooling)

Max Input Power

Max Input Current

Ambient Temperature

Heat Exchanger

Refrigerant

Compressor Type

Number of Compressors

Number of Fans

Fan Air Flow Volume

Fan Direction

Fan Power Input

Fan Rotation Speed

Noise

Piping Diameter

Discharge Pressure

Suction Pressure

Rated Water Pressure

Water Flow Volume

Net Weight

220-240V/1N~/50Hz 380V-415V/3N~/50Hz

0.9/1.05

4.3/5.0

1.4

6.7

1.45/1.65

6.9/7.9

1.9

9.1

2.06/2.20

9.9/10.5

2.5

12

3.12/3.30

14.9/15.8

3.4

16.3

4.3/5.50

8.2/10.4

6.1

11.6

- 7℃~43℃

PVC shell Titanium tulae in

R410A R407C

Rotary Scroll

1 1 1 1 1

1 1 1 1 2

2000 2000 2600 3900 6500

Horizontal

20

850

≤48

Rc1-1/2"

20

850

≤48

Rc1-1/2"

40

850

≤50

Rc1-1/2"

90

750

≤54

Rc1-1/2"

90x2

850

≤56

Rc1-1/2"

2.5

0.3-0.8

0.2~0.6

1.3-1.9

38

2.0-3.0

45

2.8-4.2

68

3.9-5.8

95

6.1-9.1

114

mmProduct Dimension 930/350/550 930/350/550 1010/350/620 1115/425/710 1110/420/1222

45

New times swimming pool heat

pump app l ies t i tan ium co i l

exchanger and hea t pump

technology which can move heat

from surrounding to the pool

water.The use of R410A refrigerant

makes the un i t i n pe r fec t

performance and more eco-friendly.

This series is specially suitable for

res iden t ia l sw imming poo l .

*

*

*

*

*

Tube in tube titanium heat exchanger/tube in shell

All range of capacity from 4.5kW to 21.3kW

Stable running, economic & durable

Emerson thermal expansion valve

Cooling & Heating

Page 6: HEAT PUMP - Nanodomi · Tube in tube titanium heat exchanger/tube in shell ... New times swimming pool heat pump applies titanium coil exchanger and heat pump technology

07 08

Specifications

Features:

Commercial Pool Heat Pumps

*

*

*

*

*

Scroll compressor

R407c refrigerant

Intelligent defrosting

Compact structure

Easy installation & operation;

Tube in tube titanium/Tube in shell heat exchanger

All range of capacity from 13.5kW to 140kW

Stable running, economic & durable

Emerson thermal expansion valve

Cooling & Heating

*

*

*

*

*

Model

HP

Heating Capacity

COP

Cooling Capacity

EER

Max Water Outlet Temperature

Power Supply

Rated Input Power (Heating/Cooling)

Rated Input Current (Heating/ Cooling)

Max Input Power

Max Input Current

Ambient Temperature

Heat Exchanger

Refrigerant

Compressor Type

Number of Compressors

Number of Fans

Fan Air Flow Volume

Fan Direction

Fan Power Input

Fan Rotation Speed

Noise

Piping Diameter

Discharge Pressure

Suction Pressure

Rated Water Pressure

Water Flow Volume

Net Weight

Units

kW

BTU/h

----

kW

BTU/h

----

V/PH/HZ

kW

A

kW

A

m /h3

W

RPM

dB (A)

mm

Mpa

Mpa

MPa

3m /h

Kg

HLRD9-YC

3HP

13.5

46100

4.33

8.8

30000

2.67

HLRD15-YC

5HP

21.3

72700

4.95

14.7

50200

2.67

HLRD24-YC

8HP

35.5

121100

4.86

25.5

87000

3.00

HLRD30-YC

10HP

45.5

155200

4.84

30.5

104100

2.77

HLRD36-YC

12HP

52.8

180200

4.74

35.8

122100

2.86

HLRD45-YC

15HP

66

225200

4.46

44.9

153200

2.77

HLRD60-YC

20HP

87.4

298200

4.65

59.5

203000

2.71

HLRD75-YC

25HP

110

375300

4.72

75

255900

2.80

HLRD95-YC

30HP

140

477700

4.86

95.2

324800

2.83

45

380V-415V/3N~/50Hz220-240V/1N~/50Hz

3.12/3.30

14.9/15.8

3.4

16.3

4.3/5.50

8.2/10.4

6.1

11.6

7.30/8.50

13.9/16.1

10

19.0

9.40/11.00

17.9/20.9

13.5

25.6

11.15/12.50

21.2/23.7

15.1

28.7

14.80/16.20

28.1/30.8

18.9

35.9

18.80/22.00

35.7/41.8

25.4

48.2

23.30/26.80

44.3/50.9

31.5

59.8

28.80/33.6

54.7/63.8

38.8

73.7

-10℃~43℃

Scroll

2 1

1

1

1 2

2 2 2 2 2 2

2 2 2 2 2 2

3900 6500 13000 13000 13000 19500 28000 28000 38000

Vertical

90

750

≤54

Rc1-1/2"

250

850

≤56

Rc1-1/2"

250*2

850

≤61

Rc2"

250*2

850

≤61

Rc2"

250*2

850

≤66

Rc2"

550×2

910

≤66

Rc2"

750*2

940

≤66

Rc3"

750*2

940

≤68

Rc3"

1100*2

920

≤70

Rc3"

2.5

0.3-0.8

0.2~0.6

4

90

6

114

10

214

13

244

15

276

19

450

25

472

31

680

40

720

Product Dimension mm 695/655/740 703/687/930 1450/705/965 1450/705/1065 1450/710/1255 1580/850/1570 1990/980/2050 1990/980/2050 1900/1020/2050

Note:

1. Heating working condition: Outdoor DB/WB temp: 24℃/19℃,62.5%RH, inlet water temp:26℃.

2. Cooling working condition: Outdoor DB/WB temp: 43℃/37℃,68%RH, inlet water temp:32℃.

R407C

Tube in tube Titanium heat exchanger / Titanium tube in PVC shell

New times swimming pool heat pump applies titanium coil exchanger and heat pump technology

which can move heat from surrounding to the pool water.The use of R407C refrigerant makes the unit

in perfect performance and more eco-friendly. This series is specially suitable for commercial

swimming pool.

Page 7: HEAT PUMP - Nanodomi · Tube in tube titanium heat exchanger/tube in shell ... New times swimming pool heat pump applies titanium coil exchanger and heat pump technology

09

Features:

10

Hot sanitary water

Energy saving Eco-friendly

R134a refrigerant

Compact design

Intelligent defrosting

Auto pressure unloading protection

Safe, reliable &eco-friendly

Stable running

Low noise & vibration

Long service life

Easy installation & operation

*

*

*

*

*

*

*

*

*

Easy installation

Specifications

The Domestic All in One Heat Pump is unique and exceptional

in every way. It will generate domestic hot water from heat within the home. The All in One Heat Pump also dehumidifies air to recover waste heat. The by-product of the All in One Heat Pump is cold air that can be recycled into the house to provide cooling for a larder, bedrooms and storage rooms in summer, and so on.

Model

Heating capacity

COP

Water tank volume

Rated heated water output

Rated outlet water temp

Max outlet water temp

Rated power input

Rated current

Power supply

Compressor type

Number of Compressors

Heat exchanger type

Throttling device

Fan type

Fan discharge

Fan quantity

Fan input

Fan speed

Ambient temperature

Refrigerant

Noise in 1 meter distance

Water pipe connector size

Cabinet

Low pressure protection system

High pressure protection system

Water flow switch

Automatic defrosting system

Product Net weight

Product dimensions

Testing condition

kW

 

L

L/h

w

A

V/Hz/Ph

 

 

 

 

 

 

 

W

RPM

 

dB

 

 

 

 

 

 

kg

mm

KH60-A/150L

1.8

3.6

150

39

KH60-A/200L

1.8

3.6

200

39

KH60-A/250L

1.8

3.6

250

39

KH60-A/300L

1.8

3.6

300

39

55

60

500 500 500 500

2.4 2.4 2.4 2.4

220-240V/50Hz/1Ph

Rotary

1

External coil

Electrical expansion valve

High efficiency and low noise centrifugal fan

Top with 5m exhaust pipe

1

200

920

200

920

200

920

200

920

(0℃~43℃)

R134a

43dB(A)

G3/4"

Stainless steel or galvanized powder coated steel

Yes

Yes

No

Yes

73 90 99 107

∮560*1475 ∮560*1760 ∮560*1900 ∮640*1860

Ambient temp.(DB/WB) = 20℃/ 15 ℃, water temp.(input/output) = 15℃/55℃

All In One Heat Pumps (A series)

Page 8: HEAT PUMP - Nanodomi · Tube in tube titanium heat exchanger/tube in shell ... New times swimming pool heat pump applies titanium coil exchanger and heat pump technology

11 12

Hot sanitary water

Energy saving Eco-friendly Easy

installation

Specifications

This series of Domestic All in One Heat

Pump is Unique and Exceptional Design. It

adopts Double tanks, high eff iciency

Compressor and Heat Exchanger, which

ensure not only high efficiency performance of

the system but also stable outlet water

temperature.

Double tanks Water

circulation

*

*

*

*

*

*

*

*

*

*

Double tanks

High efficiency R134a special Heat Pump

Compressor

High efficiency tube in shell Heat Exchanger

Water pump built in

Intelligent defrosting

Intelligent controller

Auto pressure unloading protection

Low noise & vibration

Long service life

Easy installation & operation

Features:

Model

Heating capacity

COP

Water tank volume

Rated heated water output

Rated output water temp

Max outlet water temp

Rated power input

Rated current

Power supply

Compressor type

Number of compressor

Heat exchanger type

Throttling device

Fan type

Fan discharge

Fan quantity

Fan input

Fan speed

Ambient temp

Refrigerant

Noise in 1 meter distance

Water pipe connection size

Cabinet

Low pressure protection system

High pressure protection system

Water flow switch

Automatic defrosting system

Product Net weight

Product dimension

Testing condition

3kW

3.8

60 L

65L/h

55℃

60℃

800W

3.8A

220V- /50Hz/1Ph240V

Rotary

1

High efficiency tube in shell

Capillary

High efficiency and low noise centrifugal fan

Top with 5m exhaust pipe

1

200W

920RPM

0 ℃-43℃

R22/R134a

43 dB (A)

G1/2”(inlet/outlet),G3/4”(circulating)

Galvanized powder coated steel

Yes

Yes

No

Yes

88 kg

550*310*1400 mm

Ambient temp. (DB/WB)=20℃/15℃, water temp.(input/output) =15℃/55℃.

air in air out

KH60-B/60L

All In One Heat Pumps (B series)

Page 9: HEAT PUMP - Nanodomi · Tube in tube titanium heat exchanger/tube in shell ... New times swimming pool heat pump applies titanium coil exchanger and heat pump technology

13

Intelligent defrosting

Famous brand rotary compressor

R22/R410A refrigerant

Horizontal fan discharge

Safe, reliable, stable running & durable

Concise design

Easy installation & operation

Intelligent controller

*

*

*

*

*

*

*

*

Features:

Pressured water tank with external copper

coil heating exchanger

Pressured water tank with internal copper

/ 316 coil heating exchanger

Floor standing water tank and wall

mounted water tank

*

*

*

SS

Optional:

14

Model

Heating capacity

COP

Water tank volume

Rated heated water output

Rated outlet water temp

Max outlet water temp

Rated power input

Rated current

Power supply

Compressor type

Number of Compressors

Heat exchanger type

Throttling device

Fan type

Fan discharge

Fan quantity

Fan input

Fan speed

Ambient temperature

Refrigerant

Noise in 1 meter distance

Water pipe size

Cabinet

Low pressure protection system

High pressure protection system

Water flow switch

Automatic defrosting system

Product dimensions mm

dB

W

RPM

kW

 

L

L/h

kw

A

V/Hz/Ph

KF80-A/100F

3.5

4.12

100

75

KF80-A/150F

3.5

4.12

150

75

KF120-A/100F

4.9

3.98

100

105

KF120-A/200F

4.9

3.98

200

105

KF120-A/320F

4.9

3.98

320

105

55

60

0.85 0.85 1.23 1.23 1.23

4.07 4.07 5.89 5.89 5.89

220-240V/50Hz/1Ph

Rotary

1

Copper coil pipe/ss316 pipe

Capillary

Low noise high efficiency axial type

Horizontal

1

20

830

20

830

20

830

20

830

20

830

(-7℃~43℃)

R22/R410A

≤54dB(A)

Rc3/4

Yes

Yes

No

Yes

galvanized powder coated steel

850×260×540 850×260×540 850×260×540 850×260×540 850×260×540

Eco-friendly Hot sanitary

water Energy saving

Specifications

This type of Domestic Split Heat Pump adopts

copper/SS316 coil heat exchanger inside/outside

the pressurized water tank, supplying sanitary hot

water for homes and residence.

Testing condition Ambient temp.(DB/WB) = 20℃/ 15 ℃, . = 15℃/55℃ water temp.(input/output)

Product dimensions(water tank) mm ¢470*1121 ¢470*1592 ¢470*1121 ¢555*1333 ¢555*1839

31 31 33 33 33Product Net weight kg

28 34 28 48 58Net weight(water tank) kg

Package dimensions mm 930×370×620 930×370×620 930×370×620 930×370×620 930×370×620

Split Heat Pumps

Page 10: HEAT PUMP - Nanodomi · Tube in tube titanium heat exchanger/tube in shell ... New times swimming pool heat pump applies titanium coil exchanger and heat pump technology

15

Features: Optional:

16

* *

* *

* *

* *

Famous brand compressor Water pump built in monobloc

Automatic defrosting Intelligent control

Safe, reliable ,stable running Long working life

Low noise & vibration Easy to install & operate

*

*

*

Refrigerant: R22, R410A, R134A,

R417A, R407C

Cabinet: Stainless steel / galvanized

powder coated steel

Heating exchanger: tube-in-shell

V/Hz/Ph

Model

Heating capacity

COP

Rated heated water output

Rated outlet water temp.

Max outlet water temp.

Rated power input

Rated current

Power supply

Compressor type

Number of Compressors

Heat exchanger type

Throttling device

Fan type

Fan discharging

Fan quantity

Fan input

Fan speed

Ambient temperature

Refrigerant

Noise in 1 meter distance

Water pipe size

Suggested water tank capacity

Cabinet

Low pressure protection system

High pressure protection system

Water flow switch

Automatic defrosting system

Product Dimensions

Product Net weight

Testing condition

kW

 

L/h

kw

A

 

 

 

 

 

 

 

W

RPM

 

dB

inch

L

 

 

 

 

 

mm

kg

KF80-B

3.5

4.12

75

KF120-B

5

4.17

110

KF160-B

7.4

4.01

160

KF240-B

11.2

4.46

240

KF400-B

18.6

4.14

400

KF480-B

22.3

4.45

480

0.85 1.2 1.85 2.5 4.5 5

4.07 5.74 8.85 11.96 8.55 23.9

220-240V/50Hz/1Ph 380-415V/50Hz/3Ph

220-240V/50Hz/1Ph 

Rotary Scroll

1 1 1 1 1 2

High efficiency tube in shell heat exchanger

Capillary EEV expansion Emerson thermal valve

Low noise high efficiency axial type

Horizontal

1

20

830

(-7℃~43℃)

R22/R410A/R134A

≤54

Rc3/4

100-150

1

20

830

1

40

850

R417A

≤55

Rc3/4

300-500

≤54

Rc3/4

200-300

1

50

850

2

90

750

2

90

750

R22/R407C

≤59

R1

300-500

≤62

R1

500

≤62

R1-1/2

500

Stainless steel/galvanized powder coated steel

Yes

Yes

No

Yes

1005/305/587 800/400/1220 1110/530/1260 1430/700/860

Heating: Ambient temp. (DB/WB): 20℃/15℃, water : 15℃/55℃.temp. (input/output)

Specifications

55

60

This series of Domestic Monobloc Heat Pump

adopts high efficiency heat exchanger and built-

in water pump inside the heat pump, which

ensures not only high efficient performance of

the system but also easy installation.

Heating

Hot sanitary water

Energy saving

Eco-friendly

55 62 66 110 155 190

Stainless steel/galvanized powder coated steel

710/310/940 710/310/940

Package dimensions

Product Dimensions(left-right)

Package dimensions(left-right)

mm

mm

mm

930/360/560 930/360/560

755/380/950 755/380/950 1040/360/640 850/476/1235 1130/590/1285 1570/840/1050

995/370/570 995/370/570

Monobloc Heat Pumps

Page 11: HEAT PUMP - Nanodomi · Tube in tube titanium heat exchanger/tube in shell ... New times swimming pool heat pump applies titanium coil exchanger and heat pump technology

17 18

Specifications

ommercial C

Heating Hot sanitary water

Energy saving Eco-friendly

Cycle Heat PumpsHeating

55

60

Model

Heating capacity

COP

Rated heated water output

Rated outlet water temp.

Max outlet water temp

Rated power input

Rated current

Power supply

Compressor type

Number of Compressors

Heat exchanger type

Throttling device

Fan type

Fan discharging

Fan quantity

Fan input

Fan speed

Ambient temperature

Refrigerant

Noise in 1 meter distance

Water pipe size

Cabinet

Low pressure protection system

High pressure protection system

Water flow switch

Automatic defrosting system

Product Dimensions

Product Net weight

Testing condition

kW

 

L/h

kw

A

 

 

 

 

 

 

 

W

RPM

 

dB

inch

 

 

 

 

 mm

V/Hz/Ph

Yes

Yes

No

Yes

KFRS-10I

11.20

4.67

241

KFRS-20II

18.00

4.62

388

KFRS-35II

36.30

4.65

780

KFRS-45II

43.70

4.62

940

KFRS-55II

54. 40

4.69

1170

KFRS-70II

69.80

4.58

1500

KFRS-90II

87.40

4.64

1882

2.40 3.90 7.80 9.45 11.60 15.23 18.85

11.5 7.41 14.81 17.94 22.03 28.92 35.8

220-240V/50Hz/1Ph 380-415V/50Hz/3Ph

Scroll

1 1 2 2 22 2

High efficiency tube in shell heat exchanger

Emerson thermal expansion valve

Low noise high efficiency axial type

Vertical

1 1 2 2 22 2

70 250 250 250 550 750 750

850 850 850 850 910 940 940

(-7℃~43℃)

R22/R407C

59 62 63 63 66 68 68

R1 R1 R1-1/2 R1-1/2 Rc2 Rc2-1/2 Rc2-1/2

Stainless Steel/galvanized powder coated steel

710/710/795 810/810/995 1450/705/1375 1450/705/1375 1445/850/1850 1990/980/2045 1990/980/2045

Heating: Ambient temp. (DB/WB): 20 ℃/15℃, water temp. : 15℃/55℃. (input/output)

The series of New Times are designed with fan

coil for wide use in hotel, office building, hospital,

commercial residence and Research Institutes.

New Times Commercial cycle heat pump can

supply heating, hot sanitary water, floor heating.

99 137 276 305 380 552 586kg

Features:American Copeland Scroll Compressor

Easy installation and operation

R22/R407C refrigerant

* *

* *

* *

* *

*

Tube in shell heat exchanger

High efficiency evaporator Intelligent defrosting

Concise design

V style evaporator Durable & stable running

Package dimensions mm 810/810/980 920/920/1080 1580/840/1450 1580/840/1450 1580/860/2000 2090/1190/2145 2090/1190/2145

Page 12: HEAT PUMP - Nanodomi · Tube in tube titanium heat exchanger/tube in shell ... New times swimming pool heat pump applies titanium coil exchanger and heat pump technology

19 20

Specifications

ommercial C

Heating Hot sanitary water

Energy saving Eco-friendly

Direct Heat PumpsHeating

This series enhance low-grade heat from air

then exchange heat with tap water, which will

after sufficient

heat exchange. Customers can set up

temperature according to demand, comfortable

water use, stable outlet water temperature. The

units are high-efficiency and durable.

go into insulation water tank

55

60

kW

 

L/h

kw

A

 

 

 

 

 

 

 

W

RPM

 

dB

inch

 

 

 

 

mm

V/Hz/Ph

Yes

Yes

No

Yes

2.40 3.90 7.80 9.45 11.60 15.23 18.85

11.5 7.41 14.81 17.94 22.03 28.92 35.8

220-240V

/50Hz380-415V/50Hz/3Ph

Scroll

1 1 2 2 22 2

1 1 2 2 22 2

70 250 250 250 550 750 750

850 850 850 850 910 940 940

(-7℃~43℃)

R22/R407C

59 62 63 63 66 68 68

R1 R1 R1-1/2 R1-1/2 Rc2 Rc2-1/2 Rc2-1/2

Stainless Steel/galvanized powder coated steel

710/710/795 810/810/995 1450/705/1375 1450/705/1375 1445/850/1850 1990/980/2045 1990/980/2045

Model

Heating capacity

COP

Rated Heated water output

Rated outlet water temp.

Max outlet water temp

Rated power input

Rated current

Power supply

Compressor type

Number of Compressors

Heat exchanger type

Throttling device

Fan type

Fan discharging

Fan quantity

Fan input

Fan speed

Ambient temperature

Refrigerant

Noise in 1 meter distance

Water pipe size

Cabinet

Low pressure protection system

High pressure protection system

Water flow switch

Automatic defrosting system

Product Dimensions

KFS10-N-JR

11.20

4.67

241

KFS20-N-JR

18.00

4.62

388

KFS35-N-JR

36.30

4.65

780

KFS45-N-JR

43.70

4.62

940

KFS55-N-JR

54.40

4.69

1170

KFS70-N-JR

69.80

4.58

1500

KFS90-N-JR

87.40

4.64

1882

High efficiency tube in shell heat exchanger

Emerson thermal expansion valve

Low noise high efficiency axial type

Vertical

Features:R22/R407C refrigerant Tube in shell heat exchanger

Modular system design V style evaporator Economic & durable

Low noise & vibration Install and operate easily

* * *

* * *

* * *

American Copeland scroll compressor

Intelligent defrosting

 

Heating: Ambient temp. (DB/WB): 20 ℃/15℃, water temp. : 15℃/55℃. (input/output)

Product Net weight

Testing condition

99 137 276 305 380 552 586kg

Package dimensions mm 810/810/980 920/920/1080 1580/840/1450 1580/840/1450 1580/860/2000 2090/1190/2145 2090/1190/2145

Page 13: HEAT PUMP - Nanodomi · Tube in tube titanium heat exchanger/tube in shell ... New times swimming pool heat pump applies titanium coil exchanger and heat pump technology

21 22

Hot sanitary water

Low temperature -25℃

Heating Eco-friendly Energy saving

Features:

*

*

*

*

*

*

American Copeland scroll compressor

Tube in shell heat exchanger

R134A refrigerant

Low noise & vibration

Automatical defrost system

Easy to install & maintain

COP

Rated heated water output

Rated outlet water temp.

Max outlet water temp

Rated power input

Rated current

Power supply

Compressor type

Number of Compressors

Heat exchanger type

Throttling device

Fan type

Fan discharging

Fan quantity

Fan input

Fan speed

Ambient temperature

Refrigerant

Hot water circulation flow

Hot water circulation pressure drop

Noise in 1 meter distance

Water pipe size

Cabinet

Low pressure protection system

High pressure protection system

Water flow switch

Automatical defrost system

Dimension

L/h

kw

A

V/PH/Hz

W

RPM

m3/h

kPa

dB

inch

mm

2.53

183

2.56

367

2.53

650

75

80

5.06 10.00 17.93

9.61 18.99 34.05

380V-415V/3N~/50Hz

Scroll

1 2 2

High efficiency tube in shell heat exchanger

Emerson thermal expansion valve/EEV

Low noise high efficiency axial type

Vertical

250 250 750

880 880 940

1 2 2

(-15℃-43℃)

R134a

2.75 5.50 9.75

65 70 70

62 65 68

R1 R1-1/2 R2

Stainless Steel/Steel with powder coated

Yes

Yes

No

Yes

810/810/995 1450/705/1375 1990/980/2045

Net wieght kg 148 296 600

Testing condition Ambient temp. (DB/WB): 20 ℃/15℃, : 15℃/75℃. water temp.(input/output)

This series adopts the most advanced enchanced vapors

injection compressor technology,EVI heat pump delivers

higher heating capacity thereby better responding to

heating equipments than normal air source heat pumps.

Model

HP

kW

KFR-13/II-GW

5

12.80

KFR-26/II-GW

10

25.60

KFR-45/II-GW

18

45.40 Heating capacity

Specifications

High Temperature Heat Pumps

80℃

Page 14: HEAT PUMP - Nanodomi · Tube in tube titanium heat exchanger/tube in shell ... New times swimming pool heat pump applies titanium coil exchanger and heat pump technology

23 24

This series adopts the most advanced low-temperature

enhanced vapors injection compressor technology, EVI heat

pump delivers higher heating capacity at low evaporation

temperature thereby better responding to heating

requirements than normal air source heat pumps.

Hot sanitary water

Low temperature -25℃

Heating Eco-friendly Energy saving

Model

Heating capacity

COP

Rated Heated water output

Rated outlet water temp.

Max outlet water temp

Rated power input

Rated current

Power supply

Compressor type

Number of Compressors

Heat exchanger type

Throttling device

Fan type

Fan discharging

Fan quantity

Fan input

Fan speed

Ambient temperature

Refrigerant

Noise in 1 meter distance

Water pipe size

Cabinet

Low pressure protection system

High pressure protection system

Water flow switch

Automatic defrosting system

Product Dimensions

Product Net weight

Testing condition

kW

 

L/h

kW

A

V/Hz/Ph

 

 

 

 

 

 

 

W

RPM

 

dB(A)

inch

 

 

 

 

 

mm

KF240-B/D

10.3

4.42

220

2.32

11.1

220-240V/50Hz/1Ph

1

KF400-B/D

17.8

4.44

381

4.02

7.63

380-415V/50Hz/3Ph

1

KFRS- /D10I

10.3

4.42

220

2.32

11.1

220-240V/50Hz/1Ph

1

KFRS-20Ⅱ/D

17.8

4.44

381

55

60

4.02

7.63

1

KFRS-35Ⅱ/D

37.4

4.41

800

8.48

16.11

2

KFRS-45Ⅱ/D

43.4

4.51

930

9.63

18.29

380-415V/50Hz/3Ph

2

KFRS-70Ⅱ/D

69.8

4.58

1500

15.23

28.93

Scroll

2

High efficiency tube in shell heat exchanger

Emerson thermal expansion valve

Low noise high efficiency axial type

Horizontal Vertical

1

50

850

(-25℃~43℃)

R22/R407C

59

Rc1

2

90

750

63

Rc1

1

70

850

59

R1

1

250

850

62

R1

2

250

850

63

R1-1/2

2

250

850

63

R1-1/2

2

750

940

68

Rc2-1/2

Stainless Steel/

Yes

Yes

No

Yes

galvanized powder coated steel

800/400/1220 1110/530/1260 710/710/795 810/810/995 1450/705/1375 1450/705/1375 1990/980/2045

Heating: Ambient temp. (DB/WB): 20 ℃/15℃, : 15℃/55℃. water temp.(input/output)

Specifications

110 155 107 129 285 305 552

Features:*

*

*

*

*

*

*

Safe working temp down to -25℃

American Copeland scroll compressor

Tube in shell heat exchanger

R407C Refrigerant

Low noise & vibration

Automatic defrosting

Easy to install & maintain

R22/

kg

Package dimensions mm 850/476/1235 1130/590/1285 810/810/980 920/920/1080 1580/840/1450 1580/840/1450 2090/1190/2145

Low Temperature

Heat Pumps (EVI System)

Page 15: HEAT PUMP - Nanodomi · Tube in tube titanium heat exchanger/tube in shell ... New times swimming pool heat pump applies titanium coil exchanger and heat pump technology

25 26

Specifications

 

 

 

 

 

 

 

 

 

 

 

 

Model

Heating capacity

COP

Cooling capacity

EER

Power supply

Heating input power

Heating input current

Cooling input power

Cooling input current

Compressor type

Number of Compressors

Heat exchanger type(water side)

Throttling device

Fan type

Fan discharging

Fan quantity

Fan input

Fan speed

Ambient temperature

Refrigerant

Noise in 1 meter distance

Water pipe size

Cabinet

Low pressure protection system

High pressure protection system

Water flow switch

Automatic defrosting system

Product Dimensions

Product Net weight

Testing condition:

 

Yes

Yes

Yes

No

kW

 

kW

 

kw

A

kw

A

 

 

 

 

 

 

 

W

RPM

 

dB

inch

 

 

 

 

 

mm

kg

380-415V/50Hz/3Ph

2.4 3.9 7.8 9.45 11.6 15.23 18.85

11.48 7.41 14.81 17.94 22.03 28.92 35.8

Scroll

K S10-DL

7.9

3.3

7.5

2.9

F KFS20-D Ⅱ

13

3.3

12.8

3.2

L KFS35-D Ⅱ

27.5

3.5

25.30

3.1

L KFS45-D Ⅱ

32.5

3.4

31

3.2

L KFS55-D Ⅱ

42

3.6

40

3.2

L KFS70-D Ⅱ

52

3.4

50

3.1

L KFS90-D Ⅱ

68

3.6

65

3.4

L

220-240V/50Hz/1Ph

2.6 4.02 8.26 9.7 12.5 16 19

12.44 7.63 15.69 18.42 23.74 30.39 36.09

Stainless steel brazing plate heat exchanger

Emerson thermal expansion valve

Low noise high efficiency axial type

Vertical

1 1 2 2 22 2

(-7℃~43℃)

R22/R407C

59 62 63 63 66 68 68

R1 R1 R1-1/2 R1-1/2 Rc2 Rc2-1/2 Rc2-1/2

1 1 2 2 22 2

Stainless Steel/galvanized powder coated steel

710/710/795 810/810/995 1450/705/1375 1450/705/1375 1445/850/1850 1990/980/2045 1990/980/2045

112 137 311 324 406 584 626

V/Hz/Ph

250 250 250 550 750 750 70

850 850 850 910 940 940 850

Package dimensions mm 810/810/980 920/920/1080 1580/840/1450 1580/840/1450 1580/860/2000 2090/1190/2145 2090/1190/2145

Heating condition: outside temp.(DB/WB) = 7℃/6℃, water temp.(inlet/outlet) = 40℃/45℃.

Cooling condition: outside temp.(DB/WB) = 35℃/24℃, water temp.(inlet/outlet) = 12℃/7℃.

Heating Energy saving Eco-friendly Cooling

Features:*

*

*

*

Stable running, safe & reliable

Low noise & vibration

Automatic defrosting

Easy installation

*

*

*

*

American Copeland compressor

Stainless steel brazing plate heat exchanger

Super intelligence

Vertical fan discharge

Air-cooled Chiller is splendid for heating and

cooling, which are suitable for villas, hotels,

factories, schools, salons , leisure centers etc.

Air Cooled Chiller

Page 16: HEAT PUMP - Nanodomi · Tube in tube titanium heat exchanger/tube in shell ... New times swimming pool heat pump applies titanium coil exchanger and heat pump technology

27

Features:

SpecificationsKFS10-N-LR3Model

Hot water capacity

Heating capacity

Cooling capacity

COP

Rated heated water output

Rated outlet water temp.

Max outlet water temp

Heating input power

Heating input current

Cooling input power

Cooling input current

Power supply

Compressor type

Number of Compressors

Heat exchanger type(water side)

Heat exchanger type(heat recovery)

Throttling device

Fan type

Fan discharge

Fan quantity

Fan input

Fan speed

Ambient temperature

Refrigerant

Hot water circulation flow

Hot water circulation pressure drop

Chiller water circulation flow

Chiller water circulation pressure drop

Noise in 1 meter distance

Water pipe size

Cabinet

Low pressure protection system

High pressure protection system

Water flow switch

Automatic defrosting system

Product Dimensions

Product Net weight

kW

kW

kW

 

L/h

kw

A

kw

A

V/Hz/Ph

 

 

 

 

 

 

 

 

W

RPM

 

m3/h

kPa

m3/h

kPa

dB

inch

 

 

 

 

 

mm

kg

11.20

7.90

7.50

4.67

241

18.00

13.00

12.80

4.62

388

KFS20-N-LR3 KFS35-N-LR3 KFS45-N-LR3 KFS55-N-LR3 KFS70-N-LR3 KFS90-N-LR3

36.30

27.50

25.30

4.65

780

43.70

32.50

31.00

4.62

940

54.40

42.00

40.00

4.69

1170

69.80

52.00

50.00

4.58

1500

87.40

68.00

65.00

4.64

1882

55

60

2.40 3.90 7.80 9.45 11.60 15.23 18.85

11.48 7.41 14.81 17.94 22.03 28.92 35.8

2.60 4.02 8.26 9.70 12.50 16.00 19.00

12.44 7.63 15.69 18.42 23.74 30.39 36.09

220-240V/50Hz/1Ph 380-415V/50Hz/3Ph

Scroll

1 1 2 2 2 2 2

Stainless steel brazing plate heat exchanger

High efficiency tube in shell heat exchanger

Emerson thermal expansion valve

Low noise high efficiency axial type

Vertical

1 1 2 2 2 2 2

70 250 250 250 550 750 750

850 850 850 850 910 940 940

1.93

30

1.36

30

59

R1

3.1

60

2.24

40

62

R1

6.24

65

4. 73

40

63

R1-1/2

7.51

65

5.59

50

63

R1-1/2

9.35

70

7.22

55

66

Rc2

12

65

8.94

50

68

Rc2-1/2

15.03

70

11.69

50

68

Rc2-1/2

Stainless Steel/galvanized powder coated steel

(-7℃~43℃)

R22/R407C

Yes

Yes

No

Yes

710/710/795 810/810/995 1450/705/1375 1450/705/1375 1445/850/1850 1990/980/2045 1990/980/2045

28

Heating Eco-friendly Energy saving Hot sanitary water

Cooling

Multi-function Heat Pumps provide free sanitary

hot water while cooling. This series can run alone air

heating, air cooling and domestic hot water

functions. Moreover, air heating &domestic hot water

at the same time, air cooling& domestic hot water at

the same time.

R22/R407C refrigerant * * American Copeland scroll compressor

* Tube in shell and plate heat exchanger * Vertical fan discharge

* Intelligent control

* Automatic defrosting

* Low noise & vibration

* Safe, reliable & durable

* Stable running

V style evaporator *

* Easy to install

112 137 311 324 406 584 626

Package dimensions mm 810/810/980 920/920/1080 1580/840/1450 1580/840/1450 1580/860/2000 2090/1190/2145 2090/1190/2145

Testing condition:

Hot water condition: outdoor temp.(DB/WB) = 20℃/15℃, water temp.(inlet/outlet) = 15℃/55℃.

Heating condition: outside temp.(DB/WB) = 7℃/6℃, water temp.(inlet/outlet) = 40℃/45℃.

Cooling condition: outside temp.(DB/WB) = 35℃/24℃, water temp.(inlet/outlet) = 12℃/ 7℃.

Multifunctional Heat Pumps