HEAT PUMP
ontentscAbout New Times
Pool & spa heaters
Spa heat pumps
Residential pool heat pumps
Commercial pool heat pumps
Domestic hot water units
All in one heat pumps (A series)
All in one heat pumps (B series)
Split heat pumps
Monobloc heat pumps
Commercial hot water units
Commercial cycle heating heat pumps
Commercial direct heating heat pumps
High temperature heat pumps
Room heating units
Low temperature heat pumps (EVI system)
Air cooled chiller
Multifunctional heat pumps
...............................................
.......................................................
.............................................
...........................................
...........................................
..........................................
......................................................
.................................................
....................................
....................................
...........................................
................................
.......................................................
...............................................
01
03
05
07
09
11
13
15
17
19
21
23
25
27
Established in 1994, Dongguan New
Times New Energy Science &
Technology Co., Ltd always persists in
ph i losophy o f “Energy sav ing
Technology, People oriented”. We
specialize in researching, producing
and marketing heat pump water
heaters. New Times has a total
manufacturing base of more than
60,000 m2.
As one of the leading professional
manufacturers of Heat Pumps in China
with more than 20 years experience in
this field, New Times has a full
production line for heat pump. On the
whole, New Times found a R&D center
and has more than 30 well-qualified
technology elites. We have our own
mold workshop, metal plate workshop,
water tank workshop and product
testing line. Our water tank annual
output can reach 100,000 sets,
manufacturing ability of metal plate is
50,000 sets one year.
We control strictly quality for guarantee eligible products. And we have
passed ISO9001:2000 International Quality System, ISO14001
International Environmental Management System authentication,
International Standard Production Enterprise Certification and Energy-
saving Products Certification. In addition, products of New Times are
approved with CCC, CE, CB,C-Tick, SAA, EN14511 etc. In view of good
quality, New Times products are designated by the People’s Liberation
Army in CISM Village at the 29th session of Olympic Games and 2010
Shanghai World EXPO ZED Pavilion as the sole air source hot water
facilities supplier. New Times is also designated by the China National
Standards Committee as member to participate in drafting out the
National Standard for Air Source Heat Pump Water Heater industry.
Products manufactured by New Times have been exported to UK,
France, Italy, Middle East, Australia,and Africa etc. Our development
vision will keep on persisting in principle of practicability, pioneer and
innovation, and research & develop more efficient, energy-saving, eco-
friendly and safer products to make great contribution to Chinese &
worldwide energy saving and emission reduction, security and
environmental cause.
Compared to counterparts, our product advantages include safety,
energy-saving, eco-friendly, practical, durable, easy to operate and
install, stable running, low noise, intelligent defrosting etc.
About New Times
01 02
03 04
pa Heat Pumps S
Specifications
Testing condition: Heating working condition: Outdoor DB/WB temp = 24℃/19℃, 62.5%RH, inlet water temp = 26℃.
Model
Heating Capacity
COP
Max Water Outlet Temperature
Rated Input Power
Rated Input Current
Max Input Power
Max Input Current
Power Supply
Compressor Type
Number of Compressors
Heat Exchanger
Throttling device
Fan type
Fan Direction
Number of Fans
Fan Air Flow Volume
Fan Power Input
Fan Rotation Speed
Ambient Temperature
Refrigerant
Water circulation flow
Water circulation pressure drop
Noise in 1 meter distance
Piping Diameter
Cabinet
Discharge Pressure
Suction Pressure
Product Dimension
kW
BTU/h
----
℃
kW
A
kW
A
V/PH/Hz
m /h3
W
RPM
℃
m /h3
kPa
dB (A)
mm
Mpa
Mpa
mm
HLRC6-SP HLR 8-SP C HLR 10-SP C HLR 12-SPC
5.8 7.6 10.3 12.1
19800 25900 35100 41300
5.47 5.35 5.48 5.43
1.06
5.07
1.45
6.94
50
1.42
6.79
1.96
9.38
1.88
9
2.64
12.6
2.23
10.07
3.15
15.1
220-240V/1N~/50Hz
Rotary
1 1 1 1
Titanium tube in PPR shell
Capillary
Low noise high efficiency axial type
Horizontal
1 1 1 1
2000
20
850
2000
20
850
2600
40
850
2600
40
850
-7℃-43℃
R410A
1.7-2.5
30
≤48
Rc1-1/2"
2.2-3.3
30
≤48
Rc1-1/2"
2.9-4.4
30
≤54
Rc1-1/2"
3.5-5.2
30
≤54
Rc1-1/2"
Steel with powder coated
2.2-3.8
0.8-1.6
930/350/550 930/350/550 1010/350/620 1010/350/620
Net Weight Kg 45 50 60 66
Features:
*
*
*
*
*
*
*
*
Titanium tube in PPR shell heat exchanger
Rotary compressor
Intelligent defrosting
Compact configuration
Horizontal fan discharge
Easy installation
Low noise & vibration
High temperature hot water outlet
The application of R410A refrigerant which will not do harm to the
ozone layer and thus is more environmently-friendly. Titanium heat
exchanger which is corrosion resisting makes the unit with a longer
service life. This series also integrates with many intelligent functions.
This series is specially suitable for SPA.
05 06
Specifications
Residential Pool Heat Pumps
Features:*
*
*
*
*
Scroll compressor
R407c refrigerant
Intelligent defrosting
Compact structure
Easy installation & operation;
1. Heating working condition: Outdoor DB/WB temp: 24℃/19℃,62.5%RH, inlet water temp:26℃.
2. Cooling working condition: Outdoor DB/WB temp: 43℃/37℃,68%RH, inlet water temp:32℃.
Note:
9.8
33400
4.76
6.2
21200
2.82
13.5
46100
4.33
8.8
30000
2.67
21.3
72700
4.95
14.7
50200
2.67
Rated Input Current (Heating/ Cooling)
kW
BTU/h
----
kW
BTU/h
----
℃
V/PH/HZ
kW
A
kW
A
℃
m /h3
W
RPM
dB (A)
mm
Mpa
Mpa
MPa
3m /h
Kg
4.5
15400
5
3
10200
2.86
7
23900
4.83
4.5
15400
2.73
HLRC8-YC HLRC9-YC HLRC15-YCUnits HLRC3-YC HLRC5-YCModel
Heating Capacity
COP
Cooling Capacity
EER
Max Water Outlet Temperature
Power Supply
Rated Input Power (Heating/Cooling)
Max Input Power
Max Input Current
Ambient Temperature
Heat Exchanger
Refrigerant
Compressor Type
Number of Compressors
Number of Fans
Fan Air Flow Volume
Fan Direction
Fan Power Input
Fan Rotation Speed
Noise
Piping Diameter
Discharge Pressure
Suction Pressure
Rated Water Pressure
Water Flow Volume
Net Weight
220-240V/1N~/50Hz 380V-415V/3N~/50Hz
0.9/1.05
4.3/5.0
1.4
6.7
1.45/1.65
6.9/7.9
1.9
9.1
2.06/2.20
9.9/10.5
2.5
12
3.12/3.30
14.9/15.8
3.4
16.3
4.3/5.50
8.2/10.4
6.1
11.6
- 7℃~43℃
PVC shell Titanium tulae in
R410A R407C
Rotary Scroll
1 1 1 1 1
1 1 1 1 2
2000 2000 2600 3900 6500
Horizontal
20
850
≤48
Rc1-1/2"
20
850
≤48
Rc1-1/2"
40
850
≤50
Rc1-1/2"
90
750
≤54
Rc1-1/2"
90x2
850
≤56
Rc1-1/2"
2.5
0.3-0.8
0.2~0.6
1.3-1.9
38
2.0-3.0
45
2.8-4.2
68
3.9-5.8
95
6.1-9.1
114
mmProduct Dimension 930/350/550 930/350/550 1010/350/620 1115/425/710 1110/420/1222
45
New times swimming pool heat
pump app l ies t i tan ium co i l
exchanger and hea t pump
technology which can move heat
from surrounding to the pool
water.The use of R410A refrigerant
makes the un i t i n pe r fec t
performance and more eco-friendly.
This series is specially suitable for
res iden t ia l sw imming poo l .
*
*
*
*
*
Tube in tube titanium heat exchanger/tube in shell
All range of capacity from 4.5kW to 21.3kW
Stable running, economic & durable
Emerson thermal expansion valve
Cooling & Heating
07 08
Specifications
Features:
Commercial Pool Heat Pumps
*
*
*
*
*
Scroll compressor
R407c refrigerant
Intelligent defrosting
Compact structure
Easy installation & operation;
Tube in tube titanium/Tube in shell heat exchanger
All range of capacity from 13.5kW to 140kW
Stable running, economic & durable
Emerson thermal expansion valve
Cooling & Heating
*
*
*
*
*
Model
HP
Heating Capacity
COP
Cooling Capacity
EER
Max Water Outlet Temperature
Power Supply
Rated Input Power (Heating/Cooling)
Rated Input Current (Heating/ Cooling)
Max Input Power
Max Input Current
Ambient Temperature
Heat Exchanger
Refrigerant
Compressor Type
Number of Compressors
Number of Fans
Fan Air Flow Volume
Fan Direction
Fan Power Input
Fan Rotation Speed
Noise
Piping Diameter
Discharge Pressure
Suction Pressure
Rated Water Pressure
Water Flow Volume
Net Weight
Units
kW
BTU/h
----
kW
BTU/h
----
℃
V/PH/HZ
kW
A
kW
A
℃
m /h3
W
RPM
dB (A)
mm
Mpa
Mpa
MPa
3m /h
Kg
HLRD9-YC
3HP
13.5
46100
4.33
8.8
30000
2.67
HLRD15-YC
5HP
21.3
72700
4.95
14.7
50200
2.67
HLRD24-YC
8HP
35.5
121100
4.86
25.5
87000
3.00
HLRD30-YC
10HP
45.5
155200
4.84
30.5
104100
2.77
HLRD36-YC
12HP
52.8
180200
4.74
35.8
122100
2.86
HLRD45-YC
15HP
66
225200
4.46
44.9
153200
2.77
HLRD60-YC
20HP
87.4
298200
4.65
59.5
203000
2.71
HLRD75-YC
25HP
110
375300
4.72
75
255900
2.80
HLRD95-YC
30HP
140
477700
4.86
95.2
324800
2.83
45
380V-415V/3N~/50Hz220-240V/1N~/50Hz
3.12/3.30
14.9/15.8
3.4
16.3
4.3/5.50
8.2/10.4
6.1
11.6
7.30/8.50
13.9/16.1
10
19.0
9.40/11.00
17.9/20.9
13.5
25.6
11.15/12.50
21.2/23.7
15.1
28.7
14.80/16.20
28.1/30.8
18.9
35.9
18.80/22.00
35.7/41.8
25.4
48.2
23.30/26.80
44.3/50.9
31.5
59.8
28.80/33.6
54.7/63.8
38.8
73.7
-10℃~43℃
Scroll
2 1
1
1
1 2
2 2 2 2 2 2
2 2 2 2 2 2
3900 6500 13000 13000 13000 19500 28000 28000 38000
Vertical
90
750
≤54
Rc1-1/2"
250
850
≤56
Rc1-1/2"
250*2
850
≤61
Rc2"
250*2
850
≤61
Rc2"
250*2
850
≤66
Rc2"
550×2
910
≤66
Rc2"
750*2
940
≤66
Rc3"
750*2
940
≤68
Rc3"
1100*2
920
≤70
Rc3"
2.5
0.3-0.8
0.2~0.6
4
90
6
114
10
214
13
244
15
276
19
450
25
472
31
680
40
720
Product Dimension mm 695/655/740 703/687/930 1450/705/965 1450/705/1065 1450/710/1255 1580/850/1570 1990/980/2050 1990/980/2050 1900/1020/2050
Note:
1. Heating working condition: Outdoor DB/WB temp: 24℃/19℃,62.5%RH, inlet water temp:26℃.
2. Cooling working condition: Outdoor DB/WB temp: 43℃/37℃,68%RH, inlet water temp:32℃.
R407C
Tube in tube Titanium heat exchanger / Titanium tube in PVC shell
New times swimming pool heat pump applies titanium coil exchanger and heat pump technology
which can move heat from surrounding to the pool water.The use of R407C refrigerant makes the unit
in perfect performance and more eco-friendly. This series is specially suitable for commercial
swimming pool.
09
Features:
10
Hot sanitary water
Energy saving Eco-friendly
R134a refrigerant
Compact design
Intelligent defrosting
Auto pressure unloading protection
Safe, reliable &eco-friendly
Stable running
Low noise & vibration
Long service life
Easy installation & operation
*
*
*
*
*
*
*
*
*
Easy installation
Specifications
The Domestic All in One Heat Pump is unique and exceptional
in every way. It will generate domestic hot water from heat within the home. The All in One Heat Pump also dehumidifies air to recover waste heat. The by-product of the All in One Heat Pump is cold air that can be recycled into the house to provide cooling for a larder, bedrooms and storage rooms in summer, and so on.
Model
Heating capacity
COP
Water tank volume
Rated heated water output
Rated outlet water temp
Max outlet water temp
Rated power input
Rated current
Power supply
Compressor type
Number of Compressors
Heat exchanger type
Throttling device
Fan type
Fan discharge
Fan quantity
Fan input
Fan speed
Ambient temperature
Refrigerant
Noise in 1 meter distance
Water pipe connector size
Cabinet
Low pressure protection system
High pressure protection system
Water flow switch
Automatic defrosting system
Product Net weight
Product dimensions
Testing condition
kW
L
L/h
℃
℃
w
A
V/Hz/Ph
W
RPM
℃
dB
kg
mm
KH60-A/150L
1.8
3.6
150
39
KH60-A/200L
1.8
3.6
200
39
KH60-A/250L
1.8
3.6
250
39
KH60-A/300L
1.8
3.6
300
39
55
60
500 500 500 500
2.4 2.4 2.4 2.4
220-240V/50Hz/1Ph
Rotary
1
External coil
Electrical expansion valve
High efficiency and low noise centrifugal fan
Top with 5m exhaust pipe
1
200
920
200
920
200
920
200
920
(0℃~43℃)
R134a
43dB(A)
G3/4"
Stainless steel or galvanized powder coated steel
Yes
Yes
No
Yes
73 90 99 107
∮560*1475 ∮560*1760 ∮560*1900 ∮640*1860
Ambient temp.(DB/WB) = 20℃/ 15 ℃, water temp.(input/output) = 15℃/55℃
All In One Heat Pumps (A series)
11 12
Hot sanitary water
Energy saving Eco-friendly Easy
installation
Specifications
This series of Domestic All in One Heat
Pump is Unique and Exceptional Design. It
adopts Double tanks, high eff iciency
Compressor and Heat Exchanger, which
ensure not only high efficiency performance of
the system but also stable outlet water
temperature.
Double tanks Water
circulation
*
*
*
*
*
*
*
*
*
*
Double tanks
High efficiency R134a special Heat Pump
Compressor
High efficiency tube in shell Heat Exchanger
Water pump built in
Intelligent defrosting
Intelligent controller
Auto pressure unloading protection
Low noise & vibration
Long service life
Easy installation & operation
Features:
Model
Heating capacity
COP
Water tank volume
Rated heated water output
Rated output water temp
Max outlet water temp
Rated power input
Rated current
Power supply
Compressor type
Number of compressor
Heat exchanger type
Throttling device
Fan type
Fan discharge
Fan quantity
Fan input
Fan speed
Ambient temp
Refrigerant
Noise in 1 meter distance
Water pipe connection size
Cabinet
Low pressure protection system
High pressure protection system
Water flow switch
Automatic defrosting system
Product Net weight
Product dimension
Testing condition
3kW
3.8
60 L
65L/h
55℃
60℃
800W
3.8A
220V- /50Hz/1Ph240V
Rotary
1
High efficiency tube in shell
Capillary
High efficiency and low noise centrifugal fan
Top with 5m exhaust pipe
1
200W
920RPM
0 ℃-43℃
R22/R134a
43 dB (A)
G1/2”(inlet/outlet),G3/4”(circulating)
Galvanized powder coated steel
Yes
Yes
No
Yes
88 kg
550*310*1400 mm
Ambient temp. (DB/WB)=20℃/15℃, water temp.(input/output) =15℃/55℃.
air in air out
KH60-B/60L
All In One Heat Pumps (B series)
13
Intelligent defrosting
Famous brand rotary compressor
R22/R410A refrigerant
Horizontal fan discharge
Safe, reliable, stable running & durable
Concise design
Easy installation & operation
Intelligent controller
*
*
*
*
*
*
*
*
Features:
Pressured water tank with external copper
coil heating exchanger
Pressured water tank with internal copper
/ 316 coil heating exchanger
Floor standing water tank and wall
mounted water tank
*
*
*
SS
Optional:
14
Model
Heating capacity
COP
Water tank volume
Rated heated water output
Rated outlet water temp
Max outlet water temp
Rated power input
Rated current
Power supply
Compressor type
Number of Compressors
Heat exchanger type
Throttling device
Fan type
Fan discharge
Fan quantity
Fan input
Fan speed
Ambient temperature
Refrigerant
Noise in 1 meter distance
Water pipe size
Cabinet
Low pressure protection system
High pressure protection system
Water flow switch
Automatic defrosting system
Product dimensions mm
dB
W
RPM
℃
kW
L
L/h
℃
℃
kw
A
V/Hz/Ph
KF80-A/100F
3.5
4.12
100
75
KF80-A/150F
3.5
4.12
150
75
KF120-A/100F
4.9
3.98
100
105
KF120-A/200F
4.9
3.98
200
105
KF120-A/320F
4.9
3.98
320
105
55
60
0.85 0.85 1.23 1.23 1.23
4.07 4.07 5.89 5.89 5.89
220-240V/50Hz/1Ph
Rotary
1
Copper coil pipe/ss316 pipe
Capillary
Low noise high efficiency axial type
Horizontal
1
20
830
20
830
20
830
20
830
20
830
(-7℃~43℃)
R22/R410A
≤54dB(A)
Rc3/4
Yes
Yes
No
Yes
galvanized powder coated steel
850×260×540 850×260×540 850×260×540 850×260×540 850×260×540
Eco-friendly Hot sanitary
water Energy saving
Specifications
This type of Domestic Split Heat Pump adopts
copper/SS316 coil heat exchanger inside/outside
the pressurized water tank, supplying sanitary hot
water for homes and residence.
Testing condition Ambient temp.(DB/WB) = 20℃/ 15 ℃, . = 15℃/55℃ water temp.(input/output)
Product dimensions(water tank) mm ¢470*1121 ¢470*1592 ¢470*1121 ¢555*1333 ¢555*1839
31 31 33 33 33Product Net weight kg
28 34 28 48 58Net weight(water tank) kg
Package dimensions mm 930×370×620 930×370×620 930×370×620 930×370×620 930×370×620
Split Heat Pumps
15
Features: Optional:
16
* *
* *
* *
* *
Famous brand compressor Water pump built in monobloc
Automatic defrosting Intelligent control
Safe, reliable ,stable running Long working life
Low noise & vibration Easy to install & operate
*
*
*
Refrigerant: R22, R410A, R134A,
R417A, R407C
Cabinet: Stainless steel / galvanized
powder coated steel
Heating exchanger: tube-in-shell
V/Hz/Ph
Model
Heating capacity
COP
Rated heated water output
Rated outlet water temp.
Max outlet water temp.
Rated power input
Rated current
Power supply
Compressor type
Number of Compressors
Heat exchanger type
Throttling device
Fan type
Fan discharging
Fan quantity
Fan input
Fan speed
Ambient temperature
Refrigerant
Noise in 1 meter distance
Water pipe size
Suggested water tank capacity
Cabinet
Low pressure protection system
High pressure protection system
Water flow switch
Automatic defrosting system
Product Dimensions
Product Net weight
Testing condition
kW
L/h
℃
℃
kw
A
W
RPM
℃
dB
inch
L
mm
kg
KF80-B
3.5
4.12
75
KF120-B
5
4.17
110
KF160-B
7.4
4.01
160
KF240-B
11.2
4.46
240
KF400-B
18.6
4.14
400
KF480-B
22.3
4.45
480
0.85 1.2 1.85 2.5 4.5 5
4.07 5.74 8.85 11.96 8.55 23.9
220-240V/50Hz/1Ph 380-415V/50Hz/3Ph
220-240V/50Hz/1Ph
Rotary Scroll
1 1 1 1 1 2
High efficiency tube in shell heat exchanger
Capillary EEV expansion Emerson thermal valve
Low noise high efficiency axial type
Horizontal
1
20
830
(-7℃~43℃)
R22/R410A/R134A
≤54
Rc3/4
100-150
1
20
830
1
40
850
R417A
≤55
Rc3/4
300-500
≤54
Rc3/4
200-300
1
50
850
2
90
750
2
90
750
R22/R407C
≤59
R1
300-500
≤62
R1
500
≤62
R1-1/2
500
Stainless steel/galvanized powder coated steel
Yes
Yes
No
Yes
1005/305/587 800/400/1220 1110/530/1260 1430/700/860
Heating: Ambient temp. (DB/WB): 20℃/15℃, water : 15℃/55℃.temp. (input/output)
Specifications
55
60
This series of Domestic Monobloc Heat Pump
adopts high efficiency heat exchanger and built-
in water pump inside the heat pump, which
ensures not only high efficient performance of
the system but also easy installation.
Heating
Hot sanitary water
Energy saving
Eco-friendly
55 62 66 110 155 190
Stainless steel/galvanized powder coated steel
710/310/940 710/310/940
Package dimensions
Product Dimensions(left-right)
Package dimensions(left-right)
mm
mm
mm
930/360/560 930/360/560
755/380/950 755/380/950 1040/360/640 850/476/1235 1130/590/1285 1570/840/1050
995/370/570 995/370/570
Monobloc Heat Pumps
17 18
Specifications
ommercial C
Heating Hot sanitary water
Energy saving Eco-friendly
Cycle Heat PumpsHeating
55
60
Model
Heating capacity
COP
Rated heated water output
Rated outlet water temp.
Max outlet water temp
Rated power input
Rated current
Power supply
Compressor type
Number of Compressors
Heat exchanger type
Throttling device
Fan type
Fan discharging
Fan quantity
Fan input
Fan speed
Ambient temperature
Refrigerant
Noise in 1 meter distance
Water pipe size
Cabinet
Low pressure protection system
High pressure protection system
Water flow switch
Automatic defrosting system
Product Dimensions
Product Net weight
Testing condition
kW
L/h
℃
℃
kw
A
W
RPM
℃
dB
inch
mm
V/Hz/Ph
Yes
Yes
No
Yes
KFRS-10I
11.20
4.67
241
KFRS-20II
18.00
4.62
388
KFRS-35II
36.30
4.65
780
KFRS-45II
43.70
4.62
940
KFRS-55II
54. 40
4.69
1170
KFRS-70II
69.80
4.58
1500
KFRS-90II
87.40
4.64
1882
2.40 3.90 7.80 9.45 11.60 15.23 18.85
11.5 7.41 14.81 17.94 22.03 28.92 35.8
220-240V/50Hz/1Ph 380-415V/50Hz/3Ph
Scroll
1 1 2 2 22 2
High efficiency tube in shell heat exchanger
Emerson thermal expansion valve
Low noise high efficiency axial type
Vertical
1 1 2 2 22 2
70 250 250 250 550 750 750
850 850 850 850 910 940 940
(-7℃~43℃)
R22/R407C
59 62 63 63 66 68 68
R1 R1 R1-1/2 R1-1/2 Rc2 Rc2-1/2 Rc2-1/2
Stainless Steel/galvanized powder coated steel
710/710/795 810/810/995 1450/705/1375 1450/705/1375 1445/850/1850 1990/980/2045 1990/980/2045
Heating: Ambient temp. (DB/WB): 20 ℃/15℃, water temp. : 15℃/55℃. (input/output)
The series of New Times are designed with fan
coil for wide use in hotel, office building, hospital,
commercial residence and Research Institutes.
New Times Commercial cycle heat pump can
supply heating, hot sanitary water, floor heating.
99 137 276 305 380 552 586kg
Features:American Copeland Scroll Compressor
Easy installation and operation
R22/R407C refrigerant
* *
* *
* *
* *
*
Tube in shell heat exchanger
High efficiency evaporator Intelligent defrosting
Concise design
V style evaporator Durable & stable running
Package dimensions mm 810/810/980 920/920/1080 1580/840/1450 1580/840/1450 1580/860/2000 2090/1190/2145 2090/1190/2145
19 20
Specifications
ommercial C
Heating Hot sanitary water
Energy saving Eco-friendly
Direct Heat PumpsHeating
This series enhance low-grade heat from air
then exchange heat with tap water, which will
after sufficient
heat exchange. Customers can set up
temperature according to demand, comfortable
water use, stable outlet water temperature. The
units are high-efficiency and durable.
go into insulation water tank
55
60
kW
L/h
℃
℃
kw
A
W
RPM
℃
dB
inch
mm
V/Hz/Ph
Yes
Yes
No
Yes
2.40 3.90 7.80 9.45 11.60 15.23 18.85
11.5 7.41 14.81 17.94 22.03 28.92 35.8
220-240V
/50Hz380-415V/50Hz/3Ph
Scroll
1 1 2 2 22 2
1 1 2 2 22 2
70 250 250 250 550 750 750
850 850 850 850 910 940 940
(-7℃~43℃)
R22/R407C
59 62 63 63 66 68 68
R1 R1 R1-1/2 R1-1/2 Rc2 Rc2-1/2 Rc2-1/2
Stainless Steel/galvanized powder coated steel
710/710/795 810/810/995 1450/705/1375 1450/705/1375 1445/850/1850 1990/980/2045 1990/980/2045
Model
Heating capacity
COP
Rated Heated water output
Rated outlet water temp.
Max outlet water temp
Rated power input
Rated current
Power supply
Compressor type
Number of Compressors
Heat exchanger type
Throttling device
Fan type
Fan discharging
Fan quantity
Fan input
Fan speed
Ambient temperature
Refrigerant
Noise in 1 meter distance
Water pipe size
Cabinet
Low pressure protection system
High pressure protection system
Water flow switch
Automatic defrosting system
Product Dimensions
KFS10-N-JR
11.20
4.67
241
KFS20-N-JR
18.00
4.62
388
KFS35-N-JR
36.30
4.65
780
KFS45-N-JR
43.70
4.62
940
KFS55-N-JR
54.40
4.69
1170
KFS70-N-JR
69.80
4.58
1500
KFS90-N-JR
87.40
4.64
1882
High efficiency tube in shell heat exchanger
Emerson thermal expansion valve
Low noise high efficiency axial type
Vertical
Features:R22/R407C refrigerant Tube in shell heat exchanger
Modular system design V style evaporator Economic & durable
Low noise & vibration Install and operate easily
* * *
* * *
* * *
American Copeland scroll compressor
Intelligent defrosting
Heating: Ambient temp. (DB/WB): 20 ℃/15℃, water temp. : 15℃/55℃. (input/output)
Product Net weight
Testing condition
99 137 276 305 380 552 586kg
Package dimensions mm 810/810/980 920/920/1080 1580/840/1450 1580/840/1450 1580/860/2000 2090/1190/2145 2090/1190/2145
21 22
Hot sanitary water
Low temperature -25℃
Heating Eco-friendly Energy saving
Features:
*
*
*
*
*
*
American Copeland scroll compressor
Tube in shell heat exchanger
R134A refrigerant
Low noise & vibration
Automatical defrost system
Easy to install & maintain
COP
Rated heated water output
Rated outlet water temp.
Max outlet water temp
Rated power input
Rated current
Power supply
Compressor type
Number of Compressors
Heat exchanger type
Throttling device
Fan type
Fan discharging
Fan quantity
Fan input
Fan speed
Ambient temperature
Refrigerant
Hot water circulation flow
Hot water circulation pressure drop
Noise in 1 meter distance
Water pipe size
Cabinet
Low pressure protection system
High pressure protection system
Water flow switch
Automatical defrost system
Dimension
L/h
℃
℃
kw
A
V/PH/Hz
W
RPM
℃
m3/h
kPa
dB
inch
mm
2.53
183
2.56
367
2.53
650
75
80
5.06 10.00 17.93
9.61 18.99 34.05
380V-415V/3N~/50Hz
Scroll
1 2 2
High efficiency tube in shell heat exchanger
Emerson thermal expansion valve/EEV
Low noise high efficiency axial type
Vertical
250 250 750
880 880 940
1 2 2
(-15℃-43℃)
R134a
2.75 5.50 9.75
65 70 70
62 65 68
R1 R1-1/2 R2
Stainless Steel/Steel with powder coated
Yes
Yes
No
Yes
810/810/995 1450/705/1375 1990/980/2045
Net wieght kg 148 296 600
Testing condition Ambient temp. (DB/WB): 20 ℃/15℃, : 15℃/75℃. water temp.(input/output)
This series adopts the most advanced enchanced vapors
injection compressor technology,EVI heat pump delivers
higher heating capacity thereby better responding to
heating equipments than normal air source heat pumps.
Model
HP
kW
KFR-13/II-GW
5
12.80
KFR-26/II-GW
10
25.60
KFR-45/II-GW
18
45.40 Heating capacity
Specifications
High Temperature Heat Pumps
80℃
23 24
This series adopts the most advanced low-temperature
enhanced vapors injection compressor technology, EVI heat
pump delivers higher heating capacity at low evaporation
temperature thereby better responding to heating
requirements than normal air source heat pumps.
Hot sanitary water
Low temperature -25℃
Heating Eco-friendly Energy saving
Model
Heating capacity
COP
Rated Heated water output
Rated outlet water temp.
Max outlet water temp
Rated power input
Rated current
Power supply
Compressor type
Number of Compressors
Heat exchanger type
Throttling device
Fan type
Fan discharging
Fan quantity
Fan input
Fan speed
Ambient temperature
Refrigerant
Noise in 1 meter distance
Water pipe size
Cabinet
Low pressure protection system
High pressure protection system
Water flow switch
Automatic defrosting system
Product Dimensions
Product Net weight
Testing condition
kW
L/h
℃
℃
kW
A
V/Hz/Ph
W
RPM
℃
dB(A)
inch
mm
KF240-B/D
10.3
4.42
220
2.32
11.1
220-240V/50Hz/1Ph
1
KF400-B/D
17.8
4.44
381
4.02
7.63
380-415V/50Hz/3Ph
1
KFRS- /D10I
10.3
4.42
220
2.32
11.1
220-240V/50Hz/1Ph
1
KFRS-20Ⅱ/D
17.8
4.44
381
55
60
4.02
7.63
1
KFRS-35Ⅱ/D
37.4
4.41
800
8.48
16.11
2
KFRS-45Ⅱ/D
43.4
4.51
930
9.63
18.29
380-415V/50Hz/3Ph
2
KFRS-70Ⅱ/D
69.8
4.58
1500
15.23
28.93
Scroll
2
High efficiency tube in shell heat exchanger
Emerson thermal expansion valve
Low noise high efficiency axial type
Horizontal Vertical
1
50
850
(-25℃~43℃)
R22/R407C
59
Rc1
2
90
750
63
Rc1
1
70
850
59
R1
1
250
850
62
R1
2
250
850
63
R1-1/2
2
250
850
63
R1-1/2
2
750
940
68
Rc2-1/2
Stainless Steel/
Yes
Yes
No
Yes
galvanized powder coated steel
800/400/1220 1110/530/1260 710/710/795 810/810/995 1450/705/1375 1450/705/1375 1990/980/2045
Heating: Ambient temp. (DB/WB): 20 ℃/15℃, : 15℃/55℃. water temp.(input/output)
Specifications
110 155 107 129 285 305 552
Features:*
*
*
*
*
*
*
Safe working temp down to -25℃
American Copeland scroll compressor
Tube in shell heat exchanger
R407C Refrigerant
Low noise & vibration
Automatic defrosting
Easy to install & maintain
R22/
kg
Package dimensions mm 850/476/1235 1130/590/1285 810/810/980 920/920/1080 1580/840/1450 1580/840/1450 2090/1190/2145
Low Temperature
Heat Pumps (EVI System)
25 26
Specifications
Model
Heating capacity
COP
Cooling capacity
EER
Power supply
Heating input power
Heating input current
Cooling input power
Cooling input current
Compressor type
Number of Compressors
Heat exchanger type(water side)
Throttling device
Fan type
Fan discharging
Fan quantity
Fan input
Fan speed
Ambient temperature
Refrigerant
Noise in 1 meter distance
Water pipe size
Cabinet
Low pressure protection system
High pressure protection system
Water flow switch
Automatic defrosting system
Product Dimensions
Product Net weight
Testing condition:
Yes
Yes
Yes
No
kW
kW
kw
A
kw
A
W
RPM
℃
dB
inch
mm
kg
380-415V/50Hz/3Ph
2.4 3.9 7.8 9.45 11.6 15.23 18.85
11.48 7.41 14.81 17.94 22.03 28.92 35.8
Scroll
K S10-DL
7.9
3.3
7.5
2.9
F KFS20-D Ⅱ
13
3.3
12.8
3.2
L KFS35-D Ⅱ
27.5
3.5
25.30
3.1
L KFS45-D Ⅱ
32.5
3.4
31
3.2
L KFS55-D Ⅱ
42
3.6
40
3.2
L KFS70-D Ⅱ
52
3.4
50
3.1
L KFS90-D Ⅱ
68
3.6
65
3.4
L
220-240V/50Hz/1Ph
2.6 4.02 8.26 9.7 12.5 16 19
12.44 7.63 15.69 18.42 23.74 30.39 36.09
Stainless steel brazing plate heat exchanger
Emerson thermal expansion valve
Low noise high efficiency axial type
Vertical
1 1 2 2 22 2
(-7℃~43℃)
R22/R407C
59 62 63 63 66 68 68
R1 R1 R1-1/2 R1-1/2 Rc2 Rc2-1/2 Rc2-1/2
1 1 2 2 22 2
Stainless Steel/galvanized powder coated steel
710/710/795 810/810/995 1450/705/1375 1450/705/1375 1445/850/1850 1990/980/2045 1990/980/2045
112 137 311 324 406 584 626
V/Hz/Ph
250 250 250 550 750 750 70
850 850 850 910 940 940 850
Package dimensions mm 810/810/980 920/920/1080 1580/840/1450 1580/840/1450 1580/860/2000 2090/1190/2145 2090/1190/2145
Heating condition: outside temp.(DB/WB) = 7℃/6℃, water temp.(inlet/outlet) = 40℃/45℃.
Cooling condition: outside temp.(DB/WB) = 35℃/24℃, water temp.(inlet/outlet) = 12℃/7℃.
Heating Energy saving Eco-friendly Cooling
Features:*
*
*
*
Stable running, safe & reliable
Low noise & vibration
Automatic defrosting
Easy installation
*
*
*
*
American Copeland compressor
Stainless steel brazing plate heat exchanger
Super intelligence
Vertical fan discharge
Air-cooled Chiller is splendid for heating and
cooling, which are suitable for villas, hotels,
factories, schools, salons , leisure centers etc.
Air Cooled Chiller
27
Features:
SpecificationsKFS10-N-LR3Model
Hot water capacity
Heating capacity
Cooling capacity
COP
Rated heated water output
Rated outlet water temp.
Max outlet water temp
Heating input power
Heating input current
Cooling input power
Cooling input current
Power supply
Compressor type
Number of Compressors
Heat exchanger type(water side)
Heat exchanger type(heat recovery)
Throttling device
Fan type
Fan discharge
Fan quantity
Fan input
Fan speed
Ambient temperature
Refrigerant
Hot water circulation flow
Hot water circulation pressure drop
Chiller water circulation flow
Chiller water circulation pressure drop
Noise in 1 meter distance
Water pipe size
Cabinet
Low pressure protection system
High pressure protection system
Water flow switch
Automatic defrosting system
Product Dimensions
Product Net weight
kW
kW
kW
L/h
℃
℃
kw
A
kw
A
V/Hz/Ph
W
RPM
℃
m3/h
kPa
m3/h
kPa
dB
inch
mm
kg
11.20
7.90
7.50
4.67
241
18.00
13.00
12.80
4.62
388
KFS20-N-LR3 KFS35-N-LR3 KFS45-N-LR3 KFS55-N-LR3 KFS70-N-LR3 KFS90-N-LR3
36.30
27.50
25.30
4.65
780
43.70
32.50
31.00
4.62
940
54.40
42.00
40.00
4.69
1170
69.80
52.00
50.00
4.58
1500
87.40
68.00
65.00
4.64
1882
55
60
2.40 3.90 7.80 9.45 11.60 15.23 18.85
11.48 7.41 14.81 17.94 22.03 28.92 35.8
2.60 4.02 8.26 9.70 12.50 16.00 19.00
12.44 7.63 15.69 18.42 23.74 30.39 36.09
220-240V/50Hz/1Ph 380-415V/50Hz/3Ph
Scroll
1 1 2 2 2 2 2
Stainless steel brazing plate heat exchanger
High efficiency tube in shell heat exchanger
Emerson thermal expansion valve
Low noise high efficiency axial type
Vertical
1 1 2 2 2 2 2
70 250 250 250 550 750 750
850 850 850 850 910 940 940
1.93
30
1.36
30
59
R1
3.1
60
2.24
40
62
R1
6.24
65
4. 73
40
63
R1-1/2
7.51
65
5.59
50
63
R1-1/2
9.35
70
7.22
55
66
Rc2
12
65
8.94
50
68
Rc2-1/2
15.03
70
11.69
50
68
Rc2-1/2
Stainless Steel/galvanized powder coated steel
(-7℃~43℃)
R22/R407C
Yes
Yes
No
Yes
710/710/795 810/810/995 1450/705/1375 1450/705/1375 1445/850/1850 1990/980/2045 1990/980/2045
28
Heating Eco-friendly Energy saving Hot sanitary water
Cooling
Multi-function Heat Pumps provide free sanitary
hot water while cooling. This series can run alone air
heating, air cooling and domestic hot water
functions. Moreover, air heating &domestic hot water
at the same time, air cooling& domestic hot water at
the same time.
R22/R407C refrigerant * * American Copeland scroll compressor
* Tube in shell and plate heat exchanger * Vertical fan discharge
* Intelligent control
* Automatic defrosting
* Low noise & vibration
* Safe, reliable & durable
* Stable running
V style evaporator *
* Easy to install
112 137 311 324 406 584 626
Package dimensions mm 810/810/980 920/920/1080 1580/840/1450 1580/840/1450 1580/860/2000 2090/1190/2145 2090/1190/2145
Testing condition:
Hot water condition: outdoor temp.(DB/WB) = 20℃/15℃, water temp.(inlet/outlet) = 15℃/55℃.
Heating condition: outside temp.(DB/WB) = 7℃/6℃, water temp.(inlet/outlet) = 40℃/45℃.
Cooling condition: outside temp.(DB/WB) = 35℃/24℃, water temp.(inlet/outlet) = 12℃/ 7℃.
Multifunctional Heat Pumps