hazcat17.12.12 lores

Download HazCat17.12.12 Lores

Post on 31-Jan-2016

58 views

Category:

Documents

0 download

Embed Size (px)

DESCRIPTION

hzardous

TRANSCRIPT

  • Pro t e c t a I I I

    A c c l a i m

    C u r i e E l i t e

    L o m o n d

    Evo l u t i o n I I

    N ev i s

    N ex L E D

    S t e r l i n g I I

    8 0 0 S e r i e s

    M i c ro n ex / M a x i n ex

    N ex x u s I I

    E c l i p s e I I

  • CHALMIT2

    Chalmit, formerly known as Andrew Chalmers and Mitchell was formed in 1910as a supplier of marine equipment to shipyards in the west of Scotland.

    Today the company is one of the largest and most respected hazardous area and marinelighting companies in the world and supplies product internationally through sales offices

    and agents located in over 40 countries.

    As part of the Hubbell Harsh and Hazardous division, Chalmit can offer a global range of IEC & NECproducts suitable for hazardous area lighting and apparatus installations on any continent

    and complying with all international codes and standards.

    In addition to hazardous area luminaires, Chalmit has in-house facilities for thedesign and manufacture of fluorescent and HID control gear. This capability provides Chalmit with

    the ability to create ballasts tailored to meet the specific requirements of individual luminaires.These bespoke design services are also available to our customers upon request.

  • A CENTURY OF BRILLIANCE

    3

    INDEX PAGE INDEX PAGE

    Technical Introduction

    Products for ATEX Category 2 and Zone 1 Applications

    Protecta III Key Features

    Protecta III Ex e Fluorescent

    Protecta III E Ex e Emergency Fluorescent

    Protecta III S/S Stainless Ex e Fluorescent

    Protecta III Mounting Options

    Acclaim Ex e Recessible Fluorescent

    Acclaim Ceiling Type Options & Dimensions

    Curie Elite Ex e Recessible Fluorescent

    Curie Elite Ceiling Type Options & Dimensions

    Lomond Ex d Fluorescent

    Lomond Mounting Options & Accessories

    Evolution II Key Features

    Evolution II Ex d e Asymmetric Floodlight

    Evolution Ex d e Floodlight and Pendant

    Evolution Junior Ex d e Floodlight

    Evolution Servicing & Mounting Accessories

    Nevis Ex d e Bulkhead

    216 Ex d e Well-Glass

    238 Ex d e Well-Glass

    261 Ex d e Well-Glass

    Solas LED Floodlight

    261E and 723 Emergency Projector

    NexLED Ex e LED Bulkhead

    NexLED Ex e ib mb Emergency Bulkhead

    Universal Ex e Control Box

    Products for ATEX Category 3 and Zone 2 Applications

    Protecta n Ex n Normal & Emergency FluorescentSterling II Ex n FluorescentSterling II E Ex n Emergency FluorescentSterling II S/S Stainless Ex n FluorescentSterling II E Stainless Ex n Emergency Fluorescent800 Series Ex n FloodlightsMicronex and Maxinex Ex n Floodlights503 Ex n FloodlightNexxus II Ex nA LED BulkheadNexxus Ex n BulkheadEclipse II Key FeaturesEclipse II Ex n Well-GlassEclipse Junior Ex n Well-GlassEclipse Mounting Variations & Accessories

    4

    20

    22

    24

    26

    28

    30

    32

    34

    36

    38

    40

    42

    44

    46

    48

    50

    52

    54

    56

    58

    60

    62

    64

    66

    68

    70

    72

    74

    76

    78

    80

    82

    84

    86

    88

    90

    92

    94

    96

    Products for Industrial and Marine Applications

    Protecta Surface Mounted FluorescentProtecta E Emergency FluorescentProtecta S/S Stainless FluorescentSterling II Surface Mounted FluorescentSterling II H/F Surface Mounted FluorescentSterling II S/S Stainless FluorescentSterling II S/S H/F Stainless FluorescentAcclaim Recessed FluorescentCurie Recessed FluorescentCurie Ceiling Type Options & DimensionsSolas LED FloodlightNexLED LED BulkheadNexxus Heavy Duty Bulkhead800 Series FloodlightsMicronex and Maxinex FloodlightsDexlux Stainless Steel Floodlights503 FloodlightEclipse II Well-GlassEclipse Junior Well-GlassChieftan II Street LanternUniversal Box Control Box502 Control Box279 EPDM Bulkhead458 EPDM Floodlight

    Common Spare Parts

    Ordering InformationLamps Available from ChalmitLamp Types to use with Chalmit LuminairesHawke Cable GlandsHawke Hazardous Area EnclosuresKillark RangeLighting Design - ChalmliteChalmit Quality, Technology, ServiceNotes

    98

    100

    102

    104

    106

    108

    110

    112

    114

    116

    118

    120

    122

    124

    126

    128

    130

    132

    134

    136

    138

    140

    142

    144

    146

    165

    166

    167

    168

    170

    171

    172

    174

    175

  • TECHNICAL INTRODUCTION4

    This technical guide outlines the design and use of equipment protected against the ignition of hazardousatmospheres formed from gases, vapours or dusts. The information given applies specifically to Chalmit

    products and can also be used as a general guide.

    The guide refers to equipment and methods complying with safety practices being used throughout the world.This material is included both for completeness and because Chalmit operates throughout the worldsupplying all lighting requirements. Chalmit hazardous area products are designed and manufactured inaccordance with the best engineering practices and to well established construction standards for explosionprotected equipment.

    The equipment must be selected, installed, maintained and disposed of in accordance with any regulation orlegislation appropriate to its use. Reference must be made to the data sheets and the certification applying toeach individual product.

    The guide also refers to construction standards and application codes. The correct application of protectedequipment is a specialist subject and these notes must be treated as being only informative. In addition to theChalmit technical information users must themselves study the relevant codes of practice and constructionstandards.

    Installation operation and maintenance manuals (IOM) are enclosed with each product and are available uponrequest. These contain information essential to the safe use of the equipment and must be read andunderstood by installers and users before putting equipment into service. Much of the information is alsoavailable on the Chalmit website (www.chalmit.com). Usually this will be for the latest version of a particularrange. If detailed information on superseded product is needed Chalmit should be contacted directly.

    This revised technical introduction was prepared in 2009 during a period of transition in the history of Exstandardisation. As such this section aims to highlight some of the current initiatives underway to simplify andrationalise product standards on a global scale.

    The process of developing product standards which initially began with the invention of equipment for the safeoperation of gassy mines, led to the standardisation of the flameproof and intrinsic safety concepts forproduct design. The standardisation of equipment on a national basis is now in its final stage of transition withthe final move towards global standardisation under the IEC Ex scheme. This may cause some confusion in theshort term but leads to international uniformity.

    The early IEC standards were largely based on the national standards of European countries.

    The first EU Directive [1976] for product standardisation prompted the rapid development of Euro-normes[EN] which were numbered in the EN 50014 etc. series. Gradually the IEC 79 series, later re-numbered60079- series were updated using the EN's as a basis but with growing international input. These were mostlythe gas hazard standards. In the late 1990's it was agreed in CENELEC that all work that could be carried outat IEC level, would be, and the standards voted in parallel as IEC standards and EN's. These standards carry theEN 60079- numbering.

    The second ATEX directive [1994], see later section, introduced further factors. The directive covers gas anddust hazards and both electrical and mechanical equipment. It introduced basic requirements for safety, theEssential Health and Safety Requirements [ESHR's]. Three levels of safety Categories 1, 2 and 3 were definedeffectively as:

    Category 1 - very safe and considering two possible equipment faults

    Category 2 - safe with one fault

    Category 3 - safe in normal operation

    Although the performance criteria of the Categories aligned with the expected area of application, the Zones,the designation of equipment protection by zone was removed. The selection of a particular type of explosionprotection for a particular zone was by risk assessment.

    In order to eliminate this potentially long term anomaly at international level and to introduce the concept of adeclared level of safety, IEC agreed to introduce Equipment Protection Levels [EPL's]. These EPL's are Ga, Gband Gc for gas and Da, Db and Dc for dust. Ma and Mb also exist for mining. These are an alternative andadditional specification for equipment made in accordance with the standards.

    The key point is that the definitions of product performance are in effect identical to the ATEX Categorydefinitions. In future, rationalisation may see the EPL's incorporated into ATEX.

    The basic technical requirements for ATEX and IEC via the IEC Ex scheme (see the section on the IEC Exscheme) will therefore be identical as EPL's are introduced right across the standards series. The ATEX markingis different from IEC and must be shown in addition to the IEC marking.

    International, Regional and National Standards - Ongoing Changes

    IEC Standards & ATEX

    Rationalisation

  • 5Sub-Division

    Index to Technical Introduction

    A further effect of the introduction of EPL's is to give a definition to the emergence of sub-divisions in some ofthe protection concepts. The principle