Page 1: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Technical Sheets – December 2016

Haworth Power

Includes Power Base

Page 2: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

This page intentionally left blank.

Page 3: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Table of Contents

Power Feeds Base Feed Module PB.5 Cord Base Feed Module PB.7 Raised Floor Power Interface Jumper PB.9 Wall Feed PB.11 Concealed Base Feed Module PB.13 Top Feed Module PB.15 External Top Feed Module PB.17 Belong Top Feed Module PB.19 Infeed Harness PB.21

Power Through Power Distribuation Assembly PB.23 Flexible Power Connector PB.25 Extended Power Connector PB.27 PREMISE Vertical Power Connector PB.29 Compose Vertical Power Connector PB.31

Power Out Triplex 15 Amp Receptacle PB.33 Triplex 15 Amp Duplex Receptacle with USB Charging Outlet PB.35 Triplex 20 Amp Receptacle PB.37 15 Amp Duplex Receptacle PB.39 20 Amp Duplex Receptacle PB.41 Hardwire Junction Box PB.43 Port Kit PB.45

Wiring Schematics 3-Circuit and 4-Circuit Wiring Diagrams PB.47 3-Circuit Wiring Schematic PB.49 4-Circuit Wiring Schematic – 2+2 Configuration PB.49 3-Circuit Wiring Diagram – 3+1 Configuration PB.50

Haworth Power Technical Sheets PB.3

Power Technical Sheet | Base Feed M

odule

Page 4: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

This page intentionally left blank.

Page 5: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Haworth Power Technical Sheets PB.5

Power Technical Sheet | Base Feed M

oduleBase Feed Module

Overview• Flexible metal conduit construction for routing power to panels and tables• Provides power connection between building and power distribution assembly• Available in either 3 circuit/separate neutral or 4 circuit/shared neutral 8 wire configurations

UniGroup®TooUniGroup®PLACES®Tactics®

PREMISE®Compose®

Page 6: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical Sheet | Product D

etails

Haworth Power Technical Sheets

Power Technical Sheet | Base Feed M

odule

PB.6

General Specifications• 20 Amp 208Y/120V, 120/240V or 120V 60 Hertz rated circuits• Constructed with 1/2” flexible metal conduit, painted black, and 12 AWG wire (10 AWG for shared neutrals)• Modular power head connects at receptacle location of power distribution assembly• Use to connect between junction box of building and power distribution assembly within panel• 3 Circuit Base Feed

– Three line, three neutral, and two ground conductors – Connector head color coded black

• 4 Circuit Base Feed – Four line, two neutral, and two ground conductors – Connector head for 4 Circuit (2+2) configuration is color coded blue – Connector head for 4 Circuit (3+1) configuration is color coded green

• System polarity keyed for 3 circuit, 4 circuit (2+2) and 4 circuit (3+1)

Listings• ETL listed manufactured wiring system rated for 20A 208Y/120V, 120/240V or 120V 60 Hz per NEC Article 604• ETL listed office furnishing accessory rated for 20A 208Y/120V, 120/240V or 120V 60 Hz per Article 605• ETL listed per UL 183 and UL 1286 and CSA standard C22.2 #203 and #203.1

Applicable Codes• Base Feed Module must be installed in accordance with the National Electrical Code (NEC), the Canadian

Electrical Code (CEC), and local electrical codes

Complimentary Products• Haworth UniGroup Too®, UniGroup®, PLACES®, PREMISE®, Compose® panel systems and Tactics® table

Typical Configuration• Power distribution from building to panel systems or table

PREMISE®Compose®

4.10”1.90”

.920” .920” 3.8”3”

4’, 10’, 15’, & 25’4’, 10’, 15’, & 25’

UniGroup®TooUniGroup®PLACES®Tactics®

4 Circuit3+1 2+2

3 Circuit

4 Circuit3+1 2+2

3 Circuit

Page 7: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Haworth Power Technical Sheets

Power Technical Sheet | Cord Base Feed M

odule

Overview• Extra hard usage cord with plug for routing single circuit to panel systems• Provides quick connection between building and power distribution assembly• Available with 20 Amp plug for US applications or 15 Amp plug for Canadian applications• Available with modular connector for interface to either 3 circuit or 4 circuit style power distribution assembly

PB.7

Cord Base Feed Module

UniGroup®TooUniGroup®

PLACES®PREMISE®Compose®

Page 8: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Haworth Power Technical Sheets

Cord Base Feed Module

Power Technical Sheet | Cord Base Feed M

odule

PB.8

General Specifications• 20 Amp 120V 60 Hertz rating for US Configuration, NEMA 5-20P plug configuration• 15 Amp 120 60 Hertz rating for Canadian Configuration, NEMA 5-15P plug configuration• Not for use with isolated ground receptacles• Constructed with extra hard usage cord with 12 AWG wire• US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per

the Canadian Electrical Code (CEC)• Modular power head connects at receptacle location of power distribution assembly• Use to connect between outlet in building and circuit 1 of power distribution assembly within panel

Listings• ETL listed office furnishing accessory rated for USA Version 20A, Canadian Version to 15A. 120V 60 Hz per Article 605• ETL listed per UL 1286 and CSA standard C22.2, and USA Version to UL 1286 and CSA C22.2 #203 Canada Version to CSA C22.2 #203 only

Applicable Codes• Base Feed Module must be installed in accordance with the National Electrical Code (NEC), the Canadian

Electrical Code (CEC), and local electrical codes

Complimentary Products• Haworth UniGroup Too®, UniGroup®, PLACES®, PREMISE®, and Compose® panel systems

Typical Configuration• Single circuit power distribution from building to panel systems

UniGroup®Too, UniGroup®, PLACES®& Tactics®Cord Base Feed Side View

PREMISE® & Compose®Cord Base Feed Side View

Cord Length

20A (USA Only) Cord Base Feed

1.90”4.10”

3”

3.87

L L

L=Length

24” USA72” Canada

Page 9: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Haworth Power Technical Sheets

Power Technical Sheet | Raised Floor Pow

er Interface Jumper

PB.9

Raised Floor Power Interface Jumper

Overview• Flexible metal conduit construction for routing power from under raised floor to panels, tables and moveable walls• Provides connection between Power Base AI raised floor modular power and Power Base power distribution

assembly• Available in either 3 circuit/separate neutral or 4 circuit/shared neutral 8 wire configurations

Internal Infeed Raised Floor Base Feed Module Raised Floor Base Feed Module

UniGroup®TooUniGroup®PLACES®PREMISE®Compose®Tactics®Enclose®Reside®Beside®Intuity®Planes® Benching

UniGroup®TooUniGroup®PLACES®Tactics®

PREMISE®Compose®

Page 10: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Haworth Power Technical Sheets

Power Technical Sheet | Raised Floor Pow

er Interface Jumper

PB.10

Raised Floor Power Interface Jumper

General Specifications• 20 Amp 208Y/120V, 120/240V or 120V 60 Hertz rated circuits• Constructed with galvanized flexible metal conduit 12 AWG wire (10 AWG for shared neutrals)• Use to connect Power Base AI raised floor power components to a power distribution assembly within a panel• One end of base feed connects to a Power Base AI jumper with the use of 2-port splitter (included), the other

end connects to the receptacle connector location on a power distribution assembly with any panel• 3 Circuit System

– Three line, three neutral, and two ground conductors – Connector head is color coded black – Internal base feed head is color coded black

• 4 Circuit System – Four line, two neutral, and two ground conductors – Connector head for 4 Circuit (2+2) configuration is color coded blue – Connector head for 4 Circuit (3+1) configuration is color coded green – Internal base feed head is color coded blue for 4 circuit (2+2) and green for 4 Circuit (3+1)

• System polarity keyed for 3 circuit, 4 circuit (2+2) and 4 circuit (3+1)

Listings• ETL listed manufactured wiring system rated for 20A 208Y/120V, 120/240V or 120V 60Hz per NEC Article 604• ETL listed office furnishing accessory rated for 20A 208Y/120V, 120/240V or 120V 60 Hz per Article 605• ETL listed per UL 183 and UL 1286 and CSA standard C22.2 #203 and #203.1

Applicable Codes• Raised Floor Base Feed Module must be installed in accordance with the National Electrical Code (NEC), the

Canadian Electrical Code (CEC), and local electrical codes

Complimentary Products• Haworth UniGroup Too®, UniGroup®, PREMISE®, Compose® panel systems, Tactics® tables, Reside®, Beside®,

Planes® Benching, Intuity and Enclose® Moveable Walls

Typical Configuration• Power distribution from Haworth Power Base® AI to panel systems, table, or moveable walls

UniGroup®TooUniGroup®PLACES®Tactics® (72” length)

PREMISE®Compose®

UniGroup®TooUniGroup®PLACES®PREMISE®Compose®Tactics®Enclose®Reside®Beside®Intuity®Planes® Benching

3”

64”, 102”, 144”, & 300”

3”3”

48” 1.90”

48” 4.10”

3.87

Internal

4 Circuit3+1 2+2

3 Circuit

Page 11: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Haworth Power Technical Sheets

Power Technical Sheet | W

all Feed

PB.11

Wall Feed

Overview• Modular connector with latch mounted to 4 11/16” (119mm) steel plate• Provides connection between field supplied 4 11/16” Junction box and Haworth raised floor power interface jumper• Available in either 3 circuit/separate neutral or 4 circuit/shared neutral 8 wire configurations

Page 12: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Haworth Power Technical SheetsPB.12

Power Technical Sheet | W

all Feed

Wall Feed

General Specifications• 20 Amp 120/208Y or 120/240V 60 Hertz rated circuits• Constructed with 12 AWG wire (10 AWG for shared neutrals supplied by others)• Use to connect between 4 11/16” Junction box supplied by others and modular power jumper• 3 circuit system provides three phase conductors, three neutral conductors and two ground conductors• 4 circuit system provides four phase conductors, two neutral conductors and two ground conductors

Listings• UL listed manufactured wiring system rated for 20A 120V/208Y or 120/240V 60Hz per NEC Articale 604• UL listed per UL 183 and CSA standard C22.2 #203.1

Applicable Codes• Wall Feed must be installed in accordance with the NEC, CEC and local electrical codes

Typical Configuration• Transition from building hardwire and modular power• Conversion of furniture top feed to modular connection

Complimentary Products• Use with Systems Furniture Power Interface Jumper to connect power to Haworth Unigroup® Too, Unigroup®, Places®, PREMISE®, Compose® panel systems, Tactics® tables, Reside®, Beside®, Planes® Benching or Intuity®• Use with Haworth Unigroup® Too, Unigroup®, Places®, PREMISE®, Compose® panel systems, Tactics® tables, Reside®, Beside®, Planes® Benching or Intuity® top feed to make quick connect to Power Base AI Jumper installed above dropped ceiling.• Use with building wiring junction box for quick connect to Power Base AI Jumpers under raised floor

Top View

Power Base AI Ceiling Distribution Wall or Column

Side View

4.688”(119 mm)

1.5”(38.1 mm)

Page 13: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Haworth Power Technical Sheets PB.13

Power Technical Sheet | Concealed Base Feed M

oduleConcealed Base Feed Module

UniGroup®TooUniGroup®PLACES®PREMISE®Compose®Intuity®Planes® Benching

Overview• Junction box with modular power connector mounts within panel base raceway• Complies with New York City Code• Provides connection between building and power distribution assembly• Available in either 3 circuit/separate neutral or 4 circuit/shared neutral 8 wire configurations

Reside®Beside®Intuity®Compose® Benching

Page 14: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Haworth Power Technical Sheets

Power Technical Sheet | Concealed Base Feed M

odule

General Specifications• 20 Amp 208Y/120V , 120/240V or 120V 60 Hertz rated circuits• Constructed with 12 AWG wire (10 AWG for shared neutrals)• Junction box constructed of 16 gauge galvanized steel with three 1/2” knockouts• Junction box is 37 cubic inches• Modular power head connects at receptacle location of power

distribution assembly• Use to connect conduit from building to power distribution assembly

within panel• 3 Circuit System Concealed Base Feed

– Three line, three neutral, and two ground conductors – Connector head color coded black

• 4 Circuit System Concealed Base Feed – Four line, two neutral, and two ground conductors – Connector head for 4 Circuit (2+2) configuration is color coded blue – Connector head for 4 Circuit (3+1) configuration is color coded green

• System polarity keyed for 3 circuit, 4 circuit (2+2) and 4 circuit (3+1)

PB.14

Concealed Base Feed Module

Listings• ETL listed manufactured wiring system rated for 20A 208Y/120V,

120/240V or 120V 60 Hz per NEC Article 604 (Compose Architectural base feed only)

• ETL listed office furnishing accessory rated for 20A 208Y/120V, 120/240V or 120V 60 Hz per Article 605 (PLACES®, PREMISE®, Compose®, UniGroup Too®, and UniGroup® base feeds)

Applicable Codes• Concealed Base Feed Modules must be installed in accordance with the National Electrical Code (NEC), the

Canadian Electrical Code (CEC), and local electrical codes

Complimentary Products• Haworth UniGroup Too®, UniGroup®, PREMISE®, PLACES®, Compose®, Reside®, Beside® and Intuity® and Compose®

Benching furniture

Typical Configuration• Power distribution from building to panel systems and benching assemblies, Reside®, Beside®, Intuity® furniture

3.06

1.81”

1/2” Trade SizeKnock Out

3.7

8”

Refe

renc

e

8”

30” UniGroup Too®

30” UniGroup®

30” PLACES®

36” PREMISE®

36” Compose®

Minimum Panel Width24” Enclose®

Minimum Wall Width

Panel Width

Compose®, PREMISE®, Unigroup®,Unigroup Too® and PLACES®

ETL Listed per UL 1286 andCSA C22.2 #203

ETL Listed per UL 183 and UL 1286 andCSA C22.2 #203 and #203.1

1/2” Trade Size Knock Out

3.06

8”

NOTE: Polarity keys (A) are on3 circuit connector heads only.A

Page 15: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Haworth Power Technical Sheets

Power Technical Sheet | Top Feed M

odule

PB.15

Top Feed Module

UniGroup®TooUniGroup®PLACES®

PREMISE®Compose®

Overview• Vertical pole for routing power harness and communication cables from above dropped ceiling tiles to panel• Provides power connection between building and power distribution assembly• Available in either 3 circuit/separate neutral or 4 circuit/shared neutral 8 wire configurations or hardwire

Page 16: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Haworth Power Technical Sheets

Power Technical Sheet | Top Feed M

odule

1.26

1.26

2.4”

8”

1.72” 1.72”

PB.16

Top Feed Module

General Specifications• 20 Amp 208Y/120V, 120/240V or 120V 60 Hertz rated circuits• Harness is constructed with flexible metal conduit and 12 AWG wire (10 AWG for shared neutrals)• Top feed junction box is 4 11/16” square, 2 1/8” deep, 42 cubic inch capacity and has 1/2” knockouts• Use to connect between junction box above ceiling and power distribution assembly within panel• 3 Circuit System

– Three line, three neutral, and two ground conductors – Connector head color coded black

• 4 Circuit System – Four line, two neutral, and two ground conductors – Connector head for 4 Circuit (2+2) configuration is color coded blue – Connector head for 4 Circuit (3+1) configuration is color coded green

• System polarity keyed for 3 circuit, 4 circuit (2+2) and 4 circuit (3+1)

Listings• ETL listed manufactured wiring system rated for 20A 208Y/120V, 120/240V or 120V 60 Hz per NEC Article 604• ETL listed office furnishing accessory rated for 20A 208Y/120V, 120/240V or 120V 60 Hz per Article 605• ETL listed per UL 183 and UL 1286 and CSA standard C22.2 #203 and #203.1

Applicable Codes• Top Feed Module must be installed in accordance with the National Electrical Code (NEC), the Canadian

Electrical Code (CEC), and local electrical codes

Complimentary Products• Haworth UniGroup Too®, UniGroup®, PREMISE®, PLACES®, Compose® panel systems• Haworth Power Base® AI modular power for use above ceilings

Typical Configuration• Power distribution from building to panel systems

Pole Cross-section for: PREMISE®Compose®Belong® Intuity®

Pole Cross-section for: UniGroup Too®UniGroup®PLACES®

3 & 4 Circuit Hardwire

Example: Compose® Top Feed

Page 17: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Haworth Power Technical Sheets

Power Technical Sheet | External Top Feed M

odule

PB.17

External Top Feed Module

Overview• Vertical pole for routing power harness and communication cables from above dropped ceiling tiles to panel• Provides connection between building and distribution harness• Available in either 3 circuit/separate neutral or 4 circuit/shared neutral 8 wire configurations or hardwire

Compose® Connections PREMISE®

Page 18: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Haworth Power Technical Sheets

Power Technical Sheet | External Top Feed M

odule

PB.18

External Top Feed Module

General Specifications• 20 Amp 208Y/120V, 120/240V or 120V 60 Hertz rated circuits• Harness is constructed with flexible metal conduit and 12 AWG wire (10 AWG for shared neutrals)• Top feed junction box is 4 11/16” square, 2 1/8” deep, 42 cubic inch capacity and has 1/2” knockouts• Use to connect between junction box above ceiling and power distribution assembly with Premise or Compose

Connections panel • Mounts to Premise at

– End of run – 90˚ corner – 3 way

• Mounts to Compose Connections at end of run• 3 Circuit System

– Three line , three neutral, and two ground conductors – Connector head color coded black

• 4 Circuit System – Four line, two neutral, and two ground conductors – Connector head for 4 Circuit (2+2) configuration is color coded blue – Connector head for 4 Circuit (3+1) configuration is color coded green

• System polarity keyed for 3 circuit, 4 circuit (2+2) and 4 circuit (3+1)

Listings• ETL listed manufactured wiring system rated for 20A 208Y/120V, 120/240V or 120V 60Hz per NEC Article 604• ETL listed office furnishing accessory rated for 20A 208Y/120V, 120/240V or 120V 60 Hz per Article 605• ETL listed per UL 183 and UL 1286 and CSA standard C22.2 #203 and #203.1

Applicable Codes• External Top Feed Modules must be installed in accordance with the National Electrical Code (NEC), the

Canadian Electrical Code (CEC ), and local electrical codes

Haworth Panels System• Haworth Compose Connections panels system• Haworth Power Base® AI modular power for use above ceilings

Typical Configuration• Power distribution from above ceiling to Compose Connections

panel system

Top View

End-of-Run

3”

2 3/4”

Page 19: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Haworth Power Technical Sheets

Power Technical Sheet | Belong Top Feed M

odule

PB.19

Belong Top Feed Module

Overview• Vertical pole for routing power harness and communication cables from above dropped ceiling tiles to panel• Provides power connection between building and power distribution assembly• Available in either 3 circuit/separate neutral or 4 cirrcuit/shared neutral 8 wire configurations or hardwire

Reside®Intuity® Beside®

Page 20: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Haworth Power Technical Sheets

Power Technical Sheet | Belong Top Feed M

odule

PB.20

Beyond Top Feed Module

General Specifications• 20 Amp 208Y/120V, 120/240V or 120V 60 Hertz rated circuits• Harness is constructed with flexible metal conduit and 12 AWG wire (10 AWG for shared neutrals)• Top feed junction box is 4 11/16” square, 2 1/8” deep, 42 cubic inch capacity and has 1/2” knockouts• Use to connect between junction box above ceiling and power distribution assembly within panel• 3 Circuit System

– Three line, three neutral, and two ground conductors – Connector head color coded black

• 4 Circuit System – Four line, two neutral, and two ground conductors – Connector head for 4 Circuit (2+2) configuration is color coded blue – Connector head for 4 Circuit (3+1) configuration is color coded green

• System polarity keyed for 3 circuit, 4 circuit (2+2) and 4 circuit (3+1)

Listings• ETL listed manufactured wiring system rated for 20A 208Y/120V, 120/240V or 120V 60 Hz per NEC Article 604• ETL listed office furnishing accessory rated for 20A 208Y/120V, 120/240V or 120V 60 Hz per Article 605• ETL listed per UL 183 and UL 1286 and CSA standard C22.2 #203 and #203.1

Applicable Codes• Top Feed Module must be installed in accordance with the National Electrical Code (NEC), the Canadian

Electrical Code (CEC), and local electrical codes

Complimentary Products• Haworth Reside®, Beside® and Intuity® furniture

Typical Configuration• Power distribution from building to panel systems

Example: Reside® Top Feed

2.4”

8”

Pole Cross-section for: PREMISE®Compose®Belong® Intuity®

Page 21: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Haworth Power Technical Sheets

Power Technical Sheet | Infeed H

arness

PB.21

Infeed Harness

Overview• Flexible metal conduit construction for routing power to panels, tables and moveable walls• Provides power connection between building and power distribution assembly• Available in either 3 circuit/separate neutral or 4 circuit/shared neutral 8 wire configurations

Enclose®Beside®Reside®Intuity®Patterns®Compose®

PREMISE®UniGroup®TooTactics®PLACES®Enclose®Planes® Benching

Page 22: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Haworth Power Technical Sheets

Power Technical Sheet | Infeed H

arness

A

PB.22

Infeed Harness

General Specifications• 20 Amp 208Y/120V, 120/240V or 120V 60 Hertz rated circuits• Constructed of galvanized steel flexible conduit and 12 AWG wire (10 AWG for shared neutral) with 1/2” conduit fitting• Modular power head connects to power distribution assembly (PDA)• Use to connect between junction box of building and PDA within furniture/moveable wall• Modular power connector is polarity keyed for 3 circuit, 4 circuit (2=+2) and 4 circuit (3+1) configurations• 3 Circuit Infeed Harness

– Three line, three neutral, and two ground conductors – Connector head color coded black

• 4 Circuit System – Four line, two neutral, and two ground conductors – 2+2 configuration connector head color coded blue – 3+1 configuration connector head color coded green

Listings• ETL listed manufacturing wiring system componnet rated for 20A 208Y/120V, 120/240V or 120V 60 Hz per NEC

Article 604• ETL listed office furnishing accessory rated for 20A 208Y/120V, 120/240V or 120V 60 Hz per NEC Article 605• ETL listed per UL 183, UL 1286 and CSA standard C22.2 No. 203-M, #203 and #203.1

Applicable Codes• Infeed Harness must be installed in accordance with the National Electrical Code (NEC), the Canadian Electrical

Code (CEC) and local electrical codes.

Complimentary Products• Use with Systems Furniture Power Interface Jumper to connect power to Haworth Unigroup® Too, Unigroup®,

Places®, PREMISE®, Compose® panel systems, Tactics® tables, Reside®, Beside®, Planes® Benching or Intuity®.• Use with Haworth Unigroup® Too, Unigroup®, Places®, PREMISE®, Compose® panel systems, Tactics® tables,

Reside®, Beside®, Planes® Benching or Intuity® top feed to make quick connect to Power Base AI Jumper installed above dropped ceiling.

• Use with building wiring junction box for quick connect to Power Base AI Jumpers under raised floor.

Typical Configuration• Power Distribution from building to panel system, furniture or moveable wall

3” 3”3” 3”

4 Circuit3+1 2+2

3 Circuit

3 Circuit 4 Circuit

NOTE: Polarity keys (A) are on3 circuit connector heads only.

Page 23: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Technical Sheet | Pow

er Distribution A

ssembly

PB.23Haworth Power Technical Sheets

Power Distribution Assembly

Overview• Mounts to panel, table, or Enclose® moveable wall panel• Provides connector locations to connect other modular power components• Available in either 3 circuit/separate neutral or 4 circuit/shared neutral 8 wire configuration

UniGroup®TooUniGroup®PLACES®

PREMISE®Compose®Tactics®Enclose®Reside®Beside®Intuity®Planes® Benching

Page 24: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Technical Sheet | Pow

er Distribution A

ssembly

PB.24 Haworth Power Technical Sheets

Power Distribution Assembly

General Specifications• 20 Amp 208Y/120V, 120/240V or 120V 60 Hertz rated circuits• Constructed with 12 AWG wire (10 AWG for shared neutrals)• Allows connections of up to four power connectors and four receptacles• Infeeds may connect to receptacle or power connector location, see infeed for details.• 3 Circuit System

– Three line, three neutral, and two ground conductors – Color coded black

• 4 Circuit System – Four line, two neutral, and two ground conductors – Four Circuit (2+2) configuration is color coded with blue connector – Four Circuit (3+1) configuration is color coded with green connector

• System polarity keyed for 3 circuit, 4 circuit (2+2) and 4 circuit (3+1)

Listings• ETL listed manufactured wiring system rated for 20A 208Y/120V, 120/240V or 60Hz per NEC Article 604• ETL listed office furnishing accessory rated for 20A 208Y/120V, 120/240V or 60Hz per NEC Article 605• ETL listed per UL 183 and UL1286 and CSA standard C22.2, #203 and #203.1

Applicable Codes• Power Distribution Assembly must be installed in accordance with the National Electrical Code (NEC), the

Canadian Electrical Code (CEC), and local electrical codes

Complimentary Products• Haworth UniGroup Too, UniGroup®, PLACES®, PREMISE®, Compose® panel systems, Tactics® tables, Intuity®, Planes®

benching, Reside®, Beside® and Enclose® moveable walls

Typical Configuration• Power Distribution Assembly mounted within panel systems, tables, or moveable walls

Power Connector Location Power Connector Location

Receptacle ConnectorLocation

Receptacle ConnectorLocation

*L

3-Circuit Shown

4 Circuit3+1 2+2

3 Circuit

Page 25: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical Sheets PB.25

Power Technical Sheet | Flexible Pow

er ConnectorFlexible Power Connector

Overview• Use to route power horizontally between panels• Provides connection between two power distribution assemblies• Available in either 3 circuit/separate neutral or 4 circuit/shared neutral 8 wire configurations

UniGroup®TooUniGroup®PLACES®PREMISE®Compose®

Page 26: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical SheetsPB.26

Power Technical Sheet | Flexible Pow

er Connector

Flexible Power Connector

General Specifications• 20 Amp 208Y/120V, 120/240V or 120V 60 Hertz rated circuits• Constructed with nonmetallic raceway and 12 AWG wire (10 AWG for shared neutrals)• Use to connect between two power distribution assemblies, panel to panel• 3 Circuit System

– Three line, three neutral, and two ground conductors – Color coded black

• 4 Circuit System – Four line, two neutral, and two ground conductors – 4 Circuit (2+2) configuration is color coded with blue connector – 4 Circuit (3+1) configuration is color coded with green connector

• System polarity keyed for 3 circuit, 4 circuit (2+2) and 4 circuit (3+1)

Listings• ETL listed office furnishing accessory rated for 20A 208Y/120V, 120/240V or 120V 60 Hz per NEC Article 605• ETL listed per UL 1286 and CSA standard C22.2 #203

Applicable Codes• Flex Connectors must be installed in accordance with the National Electrical Code (NEC), the Canadian Electrical

Code (CEC), and local electrical codes

Complimentary Products• Haworth UniGroup®Too, UniGroup®, PREMISE®, and Compose® panel systems

Typical Configuration• Horizontal power distribution within panel systems.

See price list for specific application.

4 Circuit3+1 2+2

3 Circuit

3-Circuit1.72”

7” through 19”

3”

Page 27: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical Sheets PB.27

Power Technical Sheet | Extended Pow

er ConnectorExtended Power Connector

Overview• Flexible metal conduit construction for routing power horizontally• Provides connection between two power distribution assemblies• Available in either 3 circuit/separate neutral or 4 circuit/shared neutral 8 wire configurations

PREMISE®

UniGroup® TooUniGroup®PLACES®PREMISE®Compose®Tactics®Enclose®Reside®Beside®Intuity®Planes® Benching

Page 28: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical SheetsPB.28

Power Technical Sheet | Extended Pow

er ConnectorA

Extended Power Connector

General Specifications• 20 Amp 208Y/120V, 120/240V or 120V 60 Hertz rated circuits• Constructed with flexible metal conduit and12 AWG wire (10 AWG for shared neutrals)• Used to connect two power distribution assemblies when separated by a non-powered panel or panel to panel

for architectural applications which require flexible conduit.• Available in a variety of lengths.• 3 Circuit System

– Three line, three neutral, and two ground conductors – Color coded with black connector

• 4 Circuit System – Four line, two neutral, and two ground conductors – 4 Circuit (2+2) configuration is color coded with blue connector – 4 Circuit (3+1) configuration is color coded with green connector

• System polarity keyed for 3 circuit, 4 circuit (2+2) and 4 circuit (3+1)

Listings • ETL listed manufactured wiring system rated for 20A 208Y/120V, 120/240V or 120V 60Hz per NEC Article 604• ETL listed office furnishing accessory rated for 20A 208Y/120V, 120/240V or 120V 60Hz per NEC Article 605• ETL listed per UL 183 and UL1286 and CSA standard C22.2, #203 and #203.1

Applicable Codes• Extended Flexible Metal Power Connector must be installed in accordance with the National Electrical Code

(NEC), the Canadian Electrical Code (CEC), and local electrical codes

Complimentary Products• Haworth PREMISE® and Compose® panel system, Tactics® Tables, Reside® and Beside®, Planes® Benching, Intuity® and

Enclose® moveable walls

Typical Configuration• Power distribution with in panel systems, table, or moveable walls

UniGroup® TooUniGroup®PLACES®Compose®Enclose®Tactics®Reside®Beside®

PREMISE®

NOTE: Polarity keys (A)are on 3 circuit connectorheads only.

4 Circuit3+1 2+2

3 Circuit

3-Circuit Shown 3-Circuit Shown

3” 3”

3” 3”

Page 29: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical Sheets PB.29

Power Technical Sheet | PREM

ISE Vertical Power Connector

PREMISE Vertical Power Connector

PREMISE®

Overview• Use to route power vertically within PREMISE® stackable panels (requires Super Base panel)• Provides connection between two power distribution assemblies within a PREMISE® stackable panel• Available in either 3 circuit/separate neutral or 4 circuit/shared neutral 8 wire configurations

Page 30: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical SheetsPB.30

Power Technical Sheet | PREM

ISE Vertical Power Connector

PREMISE Vertical Power Connector

General Specifications• 20 Amp 208Y/120V, 120/240V or 120V 60 Hertz rated circuits• Constructed with nonmetallic raceway and 12 AWG wire (10 AWG for shared neutrals)• Use to connect between two power distribution assemblies within a PREMISE stackable panel• 3 Circuit System

– Three line, three neutral, and two ground conductors – Color coded black

• 4 Circuit System – Four line, two neutral, and two ground conductors – 4 Circuit (2+2) configuration is color coded with blue connector – 4 Circuit (3+1) configuration is color coded with green connector

• System polarity keyed for 3 circuit, 4 circuit (2+2) and 4 circuit (3+1)

Listings• ETL listed office furnishing accessory rated for 20A 208Y/120V, 120/240V or 120V 60 Hz per NEC Article 605.• ETL listed per UL 1286 and CSA standard C22.2 #203

Applicable Codes• Vertical Power Connector must be installed in accordance with the National Electrical Code (NEC), the Canadian

Electrical Code (CEC), and local electrical codes

Complimentary Products• Haworth PREMISE stackable panels system

Typical Configuration• Power distribution within PREMISE® stackable panel system

4 Circuit3+1 2+2

3 Circuit

L = Length32” Beltline48” Standing Height

3”

3.58”

L

Page 31: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical Sheets PB.31

Power Technical Sheet | Com

pose Vertical Power Connector

Compose Vertical Power Connector

Overview• Use to route power vertically with Compose® panels• Provides connection between two power distribution assemblies within a Compose® panel• Available in either 3 circuit/separate neutral or 4 circuit/shared neutral 8 wire configurations

Compose®

Page 32: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical SheetsPB.32

Power Technical Sheet | Com

pose Vertical Power Connector

Compose Vertical Connector

General Specifications• 20 Amp 208Y/120V, 120/240V or 120V 60 Hertz rated circuits• Constructed with flexible metal conduit and 12 AWG wire (10 AWG for shared neutrals)• Use to connect between two power distribution assemblies within a Compose panel• 3 Circuit System

– Three line, three neutral, and two ground conductors – Connector color coded black

• 4 Circuit System – Four line, two neutral, and two ground conductors – 4 Circuit (2+2) configuration is color coded with blue connector – 4 Circuit (3+1) configuration is color coded with green connector

• System polarity keyed for 3 circuit, 4 circuit (2+2) and 4 circuit (3+1)

Listings• ETL listed manufactured wiring system rated for 20A 208Y/120V, 120/240V or 120V 60Hz per NEC Article 604.• ETL listed office furnishing accessory rated for 20A 208Y/120V, 120/240V or 120V 60Hz per NEC Article 605.• ETL listed per UL 183 and UL1286 and CSA standard C22.2, #203 and #203.1

Applicable Codes• Vertical Power Connector must be installed in accordance with the National Electrical Code (NEC), the Canadian

Electrical Code (CEC), and local electrical codes

Complimentary Products• Haworth Compose® panel system

Typical Configuration• Power distribution within Compose® panel system

NOTE: Polarity keys (A)are on 3 circuit connector

heads only.

4 Circuit3+1 2+2

3 Circuit

A

Page 33: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical Sheets PB. 33

Power Technical Sheet | Triplex 15 A

mp Receptacle

Triplex 15 Amp Receptacle

Overview• Use to access power within PREMISE® and Compose® panel systems, Tactics® table, Reside® desking, Intuity®,

Planes® Benching and Enclose® moveable walls• Provides three 15 Amp outlets• Available for connection to either 3 circuit/separate neutral or 4 circuit/shared neutral 8 wire configurations

PREMISE®Compose®Enclose®Tactics®Reside®Intuity®Planes® Benching

Page 34: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical SheetsPB. 34

Power Technical Sheet | Triplex 15 A

mp Receptacle

Triplex 15 Amp Receptacle

General Specifications• Three outlet 15 Amp 120V 60 Hertz rated, NEMA 5-15R configuration• Available in common ground or isolated ground configuration• Snaps into power distribution assembly with receptacle face exposed through base raceway cover.

Up to 4 receptacles per power distribution assembly, maximum 2 for Moveable Walls and Tactics• 3 Circuit Receptacle

– Selector for access to circuit 1, 2, 3 – Non-ground towers on rear of receptacle are color coded white

• 4 Circuit Receptacle – Fixed circuit access – Non-ground towers on rear of 4 Circuit (2+2) receptacle are color coded blue – Non-ground towers on rear of 4 Circuit (3+1) receptacle are color coded green

• System polarity keyed for 3 circuit, 4 circuit (2+2) and 4 circuit (3+1)

Listings• ETL listed manufactured wiring system component rated for 15A 120V 60Hz per NEC Article 604• ETL listed office furnishing accessory rated for 15A 120V 60 Hz per Article 605• ETL listed per UL 183, UL 498 and UL 1286 and CSA standard C22.2, #203 and #203.1

Applicable Codes• Receptacles must be installed in accordance with the National Electrical Code (NEC), the Canadian Electrical

Code (CEC), and local electrical codes

Complimentary Products• Haworth PREMISE® and Compose® panel systems, Tactics® tables, Reside® desking, Intuity®, Planes® Benching

and Enclose® moveable walls

Typical Configuration• Power distribution within PREMISE® and Compose® panel systems, Tactics® tables, Intuity®, Planes® Benching

and Enclose® moveable walls.

Programmable3 Circuit only

Non-Programmable4 Circuit

3+1 & 2+2

BlueTowers

2+2

GreenTowers

3+1

4.63”

1.98

WhiteTowers

3 Circuit

Circuit Identifier

A = Circuit 1B = Circuit 2C = Circuit 3D = Circuit 4

1 = Circuit 12 = Circuit 23 = Circuit 34 = Circuit 4

Page 35: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical Sheets PB. 35

Power Technical Sheet | 15 A

mp D

uplex Receptacle with U

SB Charging Outlet

15 Amp Duplex Receptacle with USB Charging Outlet

Overview• Use to access power within PREMISE® and Compose® panel systems, Tactics® tables, Reside® desking, Intuity®,

Planes Benching® and Enclose® movable walls• Provides two 15 Amp outlets and two USB charging outlets• Available for connection to either 3 circuit/separate neutral or 4 circuit/shared neutral 8 wire configurations

PREMISE®Compose®Enclose®Tactics®Reside®Planes® Benching

Page 36: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical SheetsPB. 36

Power Technical Sheet | 15 A

mp D

uplex Receptacle with U

SB Charging Outlet

15 Amp Duplex Receptacle with USB Charging Outlet

General Specifications• Two outlet 15 Amp 120V 60 Hertz rated, NEMA 5-15R configuration and two USB 2.0 A type outlets• 2 Amp (shared) USB Charging Capacity: 5 V DC.• Available in common ground configuration• Snaps into power distribution assembly with receptacle face exposed through base raceway cover.

Up to 4 receptacles per power distribution assembly, maximum 2 for Moveable Walls and Tactics• 3 Circuit Receptacle

– Fixed circuit access-circuit 1 only – Non-ground towers on rear of receptacle are color coded black

• 4 Circuit Receptacle – Fixed circuit access-circuit 1 only – Non-ground towers on rear of 4 Circuit (2+2) receptacle are color coded blue – Non-ground towers on rear of 4 Circuit (3+1) receptacle are color coded green

• System polarity keyed for 3 circuit, 4 circuit (2+2) and 4 circuit (3+1)

Listings• ETL listed per UL 498 and CSA standard C22.2 #42

Applicable Codes• Receptacles must be installed in accordance with the National Electrical Code (NEC), the Canadian Electrical

Code (CEC), and local electrical codes

Complimentary Products• Haworth PREMISE® and Compose® panel systems, Tactics® table, Reside® desking, Intuity®, Planes® Benching and

Enclose® moveable walls

Typical Configuration• Power distribution within PREMISE® and Compose® panel systems, Tactics® tables, Intuity®, Planes® Benching

and Enclose® moveable walls

BlackTowers

3 Circuit

4.63”

1.98

Non-Programmable3 Circuit and 4 Circuit

3+1 & 2+2

BlueTowers

2+2

GreenTowers

3+1

Circuit Identifier

I = Circuit 1II = Circuit 2III = Circuit 3

A = Circuit 1B = Circuit 2C = Circuit 3D = Circuit 4

1 = Circuit 12 = Circuit 23 = Circuit 34 = Circuit 4

Page 37: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical Sheets PB. 37

Power Technical Sheet | Triplex 20 A

mp Receptacle

Triplex 20 Amp Receptacle

Overview• Use to access power within PREMISE® and Compose® panel systems, Tactics® table, Reside® desking, Intuity®,

Planes® Benching and Enclose® moveable walls• Provides three 20 Amp outlets• Available for connection to either 3 circuit/separate neutral or 4 circuit/shared neutral 8 wire configurations

PREMISE®Compose®Enclose®Tactics®Reside®Intuity®Planes® Benching

Page 38: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical SheetsPB. 38

Power Technical Sheet | Triplex 20 A

mp Receptacle

Triplex 20 Amp Receptacle

General Specifications• Three outlet 20 Amp 120V 60 Hertz rated, NEMA 5-15R configuration• Available in common ground or isolated ground configuration• Built to access one circuit only, circuit 1, 2, 3 or 4• Snaps into power distribution assembly with receptacle face exposed through base raceway cover.

Up to 4 receptacles per power distribution assembly, maximum 2 for Moveable Walls and Tactics• 3 Circuit Receptacle

– Selector for access to circuit 1, 2, 3 – Non-ground towers on rear of receptacle are color coded white

• 4 Circuit Receptacle – Fixed circuit access – Non-ground towers on rear of 4 Circuit (2+2) receptacle are color coded blue – Non-ground towers on rear of 4 Circuit (3+1) receptacle are color coded green

• System polarity keyed for 3 circuit, 4 circuit (2+2) and 4 circuit (3+1)

Listings• ETL listed manufactured wiring system component rated for 15A 120V 60Hz per NEC Article 604• ETL listed office furnishing accessory rated for 15A 120V 60 Hz per Article 605• ETL listed per UL 183 and UL 1286 and CSA standard C22.2, #203 and #203.1

Applicable Codes• Receptacles must be installed in accordance with the National Electrical Code (NEC), the Canadian Electrical

Code (CEC), and local electrical codes

Complimentary Products• Haworth PREMISE® and Compose® panel systems, Tactics® table, Reside® desking, Intuity®, Planes® Benching

and Enclose® moveable walls

Typical Configuration• Power distribution within PREMISE® and Compose® panel systems, Tactics® table, Intuity®, Planes® Benching and

Enclose® moveable walls

BlueTowers

2+2

GreenTowers

3+1

4.63”

2.27

WhiteTowers

3 Circuit

Circuit Identifier

I = Circuit 1II = Circuit 2III = Circuit 3

A = Circuit 1B = Circuit 2C = Circuit 3D = Circuit 4

1 = Circuit 12 = Circuit 23 = Circuit 34 = Circuit 4

Non-Programmable3 and 4 Circuit

Page 39: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical Sheets PB. 39

Power Technical Sheet | 15 A

mp D

uplex Receptacle15 Amp Duplex Receptacle

Overview• Use to access power within Unigroup Too®, Unigroup® or PLACES®• Provides two 15 Amp outlets • Available for connection to either 3 circuit/separate neutral or 4 circuit/shared neutral 8 wire configurations

Unigroup® TooUnigroup®PLACES®

Page 40: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical SheetsPB. 40

Power Technical Sheet | 15 A

mp D

uplex Receptacle

15 Amp Duplex Receptacle

General Specifications• Two outlets 15 Amp 120V 60 Hertz rated, NEMA 5-15R configuration• Available in common ground or isolated ground configuration• Snaps into power distribution assembly with receptacle face exposed through base raceway cover. Up to 4

re-ceptacles per power distribution assembly• 3 Circuit Receptacle

– Selector for access to circuit 1, 2, 3 – Non-ground towers on rear of receptacle are color coded white

• 4 Circuit Receptacle – Fixed circuit access – Non-ground towers on rear of 4 circuit (2+2) receptacle are color coded blue – Non-ground towers on rear of 4 Circuit (3+1) receptacle are color coded green

• System polarity keyed for 3 circuit, 4 circuit (2+2) and 4 circuit (3+1)

Listings• ETL listed manufactured wiring system component rated for 15A 120V 60 Hz per NEC Article 604• ETL listed office furnishing accessory rated for 15A 120V 60 Hz per NEC Article 605• ETL listed per UL 183, UL 498 and UL 1286 and CSA standard C22.2, #203 and #203.1

Applicable Codes• Receptacles must be installed in accordance with the National Electrical Code (NEC), the Canadian Electrical

Code (CEC), and local electrical codes

Complimentary Products• Haworth UniGroup® Too, UniGroup®, PLACES® panel systems

Typical Configuration• Power distribution within UniGroup®, UniGroup Too®, PLACES® panel systems

BlackTowers

3 Circuit

4.63”

1.98

Programmable3 Circuit only

Non-Programmable3+1 & 2+2

BlueTowers

2+2

GreenTowers

3+1

Circuit Identifier

A = Circuit 1B = Circuit 2C = Circuit 3D = Circuit 4

1 = Circuit 12 = Circuit 23 = Circuit 34 = Circuit 4

Page 41: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical Sheets PB. 41

Power Technical Sheet | 20 A

mp D

uplex Receptacle20 Amp Duplex Receptacle

Overview• Use to access power within Unigroup Too®, Unigroup® or PLACES®• Provides two 15 Amp outlets • Available for connection to either 3 circuit/separate neutral or 4 circuit/shared neutral 8 wire configurations

Unigroup® TooUnigroup®PLACES®

Page 42: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical SheetsPB. 42

Power Technical Sheet | 20 A

mp D

uplex Receptacle

A

20 Amp Duplex Receptacle

General Specifications• Two outlet 20 Amp 120V 60 Hertz rated, NEMA 5-20R configuration• Receptacle is circuit 1 access only• Plugs into the receptacle location on the left side of the power distribution assembly• 3 Circuit Receptacle

– Receptacle connects to 3 circuit system – Rear of receptacle color coded black

• 4 Circuit Receptacle – Non-ground towers on rear of 4 circuit (2+2) receptacle color coded blue – Non-ground towers on rear of 4 circuit (3+1) receptacle color coded green

• System polarity keyed for 3 circuit, 4 circuit (2+2) and 4 circuit (3+1) configuration

Listings• ETL listed office furnishing accessory rated for 20A 120V 60Hz per Article 605• ETL listed per UL 1286 and CSA standard C22.2, #203 and #203.1

Applicable Codes• Receptacles must be installed in accordance with the National Electrical Code (NEC) and local electrical codes

Complimentary Products• Planes®and Unigroup® 20 Amp Raceway Cover

Typical Configuration• Power distribution within UniGroup Too®, UniGroup® and PLACES® panel systems

4 Circuit3+1 2+2

3 Circuit

2.48

5”7”

NOTE: Polarity keys (A)are on 3 circuit connectorheads only.

Page 43: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical Sheets PB. 43

Power Technical Sheet | H

ardwire Junction Box

Hardwire Junction Box

Overview• Two sided junction box with brackets to mount directly to Haworth furniture and position outlet in standard

raceway cover openings.• For use when local electrical codes or special performance requirements call for hardwired power distribution

installed on site.• Designed for use with 1/2” conduit.

Compose®Reside®Intuity®PREMISE®Beside®

Page 44: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical SheetsPB. 44

Power Technical Sheet | H

ardwire Junction Box

Beltline Height

Standing HeightStanding Height

BelowWorksurface

Receptacle Plate

Back

BottomSide

Hardwire Junction Box

General Specifications• Welded and galvanized steel junction box with 35 cubic inches volume• Junction box provided with two 1/2” knockouts at each end for branching to adjacent furniture• Allows mounting two receptacles (NEMA 5-15R or 5-20R), one on each side• Duplex or rectangular receptacle face plates sold separately• Available with brackets for specific Haworth furniture, consult specific price book for proper catalog number

Listings• UL listed for 20A 120V 60 Hz circuits• UL listed per UL 1286 and CSA C22.2 #203

Applicable Codes• Hardware junction box must be installed in accordance with the National Electrical Code (NEC), the Canadian

Electrical Code (CEC) and local electrical codes

Complimentary Products• Haworth Premise®, Compose®, Reside®, Beside® and Intuity®

Typical Configuration• Mounted on Premise® or Compose® panels, Reside® or Intuity® power tray, Beside® cabinet

W

H +

18”

5”

2.48

2.40

2.82

”2.

40”

2.82”

4.81”

Dia. 0.88

4.81”

Page 45: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical Sheets PB. 45

Power Technical Sheet | Port Kit

Port Kit

Overview• Provides 15 Amp triplex receptacle and modular furniture telecommunications outlet opening above base raceway

level for UniGroup® Too, UniGroup®, PLACES®, and PREMISE® monolithic fabric panels• Available with modular connector for attachment to either 3 circuit or 4 circuit power distribution assembly

Port Kit Module Port Kit Connector

UniGroup® TooUniGroup®PLACES®PREMISE®

Page 46: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical SheetsPB. 46

Power Technical Sheet | Port Kit

General Specifications• 15 Amp 120V 60 Hertz rated single circuit connector and 15A triplex

receptacle (NEMA 5-15R)• Connector constructed with flexible metal conduit and 12 AWG wire• Connector connects to right-hand receptacle location of power

distribution assembly in base raceway• Available for below work surface (PREMISE only) and above work

surface panel locations• Available with common ground or isolated ground receptacle• Built to access one circuit only, specify circuit 1, 2, 3 or 4• 3 Circuit

– line, neutral, and ground conductors – Base connector head is color coded black

• 4 Circuit – line, neutral, and ground conductors – Base connector head for 4 Circuit (2+2) configuration is color coded blue – Base connector head for 4 Circuit (3+1) configuration is color coded green

• System polarity keyed for 3 circuit, 4 circuit (2+2) and 4 circuit (3+1)

Port Kit

Listings• ETL listed office furnishing accessory rated for 15A 208Y/120V, 120/240V or 120V 60 Hz per Article 605• ETL listed per UL 183 and UL 1286 and CSA standard C22.2, #203 and #203.1

Applicable Codes• Port Kit must be installed in accordance with the National Electrical Code (NEC), the Canadian Electrical Code

(CEC), and local electrical codes

Typical Configuration• Power access above base raceway in monolithic fabric panels

Complimentary Products• Haworth UniGroup®Too, UniGroup®, PLACES®, and PREMISE® monolithic fabric panel system

3.25”

Port Kit dimensions basedon panel height

1.38”

9”

2.71

34”

18”

Port Kit Module

PREMISE®UniGroup®TooUniGroup®PLACES®

PREMISE® only

1 1/2” UniGroup Too®2” PREMISE®

Page 47: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical Sheets

Power Technical Sheet | W

iring Diagram

PB. 47

Wiring Diagram

Circuit 1 Hot-L1-Black

Circuit1 Neutral-N1-White

Circuit 2 Neutral-N2-White/Red

Circuit 3 Neutral-N3-White/Blue

System Ground G1-Bare

Isolated Ground G2-Green/Yellow

Circuit 2 Hot-L2-Red

Circuit 3 Hot-L3-Blue

Circuit 1 Hot-L1-Black

Circuit 2 Hot-L2-Red

Circuit 3 Hot-L3-Blue

Circuit 1 Neutral-N1-White

Circuit 2 Neutral-N2-White/Red

Circuit 3 Neutral-N3-White/Blue

System Ground G1-Bare

Isolated Ground G2-Green/Yellow

1 2

Circuit 1 Hot-L1-Black

Circuit 2 Hot-L2-Red

Circuit 3 Hot-L3-Blue

Circuit 4 Hot-L4-Violet

Circuit 1 & 2 Neutral-N1-Grey

Circuit 3 & 4 Neutral-N2-Grey/Red

Systems Ground-G1-Bare

Isolated Ground-G2-Green/Yellow

Circuit 1 Hot-L1-Black

Circuit 2 Hot-L2-Red

Circuit 3 Hot-L3-Blue

Circuit 4 Hot-L4-Violet

Circuit 1, 2 & 3 Neutral-N1-Gray

Circuit 4 Neutral-N2-Gray/Red

System Ground-G1-Bare

Isolated Ground-G2-Green/Yellow

Circuit 1 Hot-L1-Black

Circuit 2 Hot-L2-Red

Circuit 3 Hot-L3-Blue

Circuit 4 Hot-L4-Violet

Circuit 1 & 2 Neutral-N1-Gray

Circuit 3 & 4 Neutral-N2-Gray/Red

Systems Ground-G1-Bare

Isolated Ground-G2-Green/Yellow

1 2

Haworth Power Base components, are offered in three different wiring schematics to allow you to match your specific wiring strategy to any typical building wiring plan. All the components in the electrical system must use the same wiring schematic. The components are color coded and keyed to assure correct polarity.

Black = Three-circuit, separate neutralsGreen = Four-circuit, 3+1Blue = Four-circuit, 2+2

In the three-circuit, each circuit is supported with its own neutral and a common ground (L1 & N1, L2 & N2, L3 & N3).

Three 208Y/120V Phase Circuit Panel

On a 3-phase circuit panel, circuits are distributed as shown.

Three Wire Single 120/240V Phase Circuit Panel

Three 208Y/120V Phase Circuit Panel

On a 3-wire single phase circuit panel, circuits are distributed

as shown.

On a single 3-phase circuit panel, circuits are distributed as shown.

On a 3 wire single phase circuit panel, circuits are distributed as shown.

On a 3-phase circuit panel, circuits are distributed as shown.

Three Wire Single 120/240V Phase Circuit Panel

Three 208Y/120V Phase Circuit Panel

Four-Circuit, 3+1 Four-Circuit, 2+2In the four-circuit, 2+2 schematic, circuits 1 and 2 aredistributed from two different phases and are supported with one shared neutral, N1. Circuits 3 and 4 are distributed from two different phases and supported by their own shared neutral, N2.

In the four-circuit 3+1 schematic, Circuits 1, 2, and 3 are supported with one shared neutral, N1. Circuit 4 is supported with a separate neutral, N2.

Page 48: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

This page intentionally left blank.

Page 49: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical Sheets PB. 49

Power Base Technical Sheet | W

iring Schematic

Wiring Schematic

3-Circuit Wiring Diagram:

3-3-2 ConfigurationCONNECTIONS TO A GROUNDED THREE-PHASE SYSTEMRATING: 208Y/120V. 3-PH WYE60Hz, 20 AMP (CSA 15 AMP)WHITE RATED AT 20 AMP (CSA 15 AMP)CIRCUITS 1, 2 & 3 EACH USE SEPARATE NEUTRALS

4-Circuit Wiring Diagram:

2+2 ConfigurationCONNECTIONS TO A GROUNDED THREE-PHASE SYSTEMRATING: 208Y/120V. 3-PH WYE60Hz, 20 AMP (CSA 15 AMP)WHITE RATED AT 35 AMP (CSA 26 AMP)MULTIWIRE BRANCH CIRCUITCIRCUIT 1 & 2 SHARE NEUTRAL 1CIRCUIT 3 & 4 SHARE NEUTRAL 2

L1 N1 G1CIRCUIT

L2 N2 G1CIRCUIT

L3 N3 G1CIRCUIT

I II III

RECEPTACLE CONNECTIONS (LOAD)Circuit 1, 2 & 3 Isolated ground receptacles also available.

WHITE/BLUEBLUE

BAREGREEN/YELLOWWHITEBLACK

WHITE/REDRED

I

II

III

RECEPTACLE CONNECTIONS (LOAD)Circuit 1, 2, 3 & 4 Isolated ground receptacles also available.

L1 N1 G1CIRCUIT

L2 N1 G1CIRCUIT

L4 N2 G1CIRCUIT

L3 N2 G1CIRCUIT

VIOLETBLUEGRAY/RED

BAREGRAYREDBLACK

GREEN/YELLOW

1

43

21

2 3 4

Page 50: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

Power Base Technical SheetsPB. 50

Power Base Technical Sheet | W

iring Schematic

Wiring Schematic (continued)

4-Circuit Wiring Diagram:

3+1 ConfigurationCONNECTIONS TO A GROUNDED THREE-PHASE SYSTEMRATING: 208Y/120V. 3-PH WYE60Hz, 20 AMP (CSA 15 AMP)WHITE RATED AT 35 AMP (CSA 26 AMP)MULTIWIRE BRANCH CIRCUITCIRCUIT 1, 2 & 3 SHARE NEUTRAL 1CIRCUIT 4 USES SEPARATE NEUTRAL 2

D

CBA

L1 N1 G1CIRCUIT

L2 N1 G1CIRCUIT

L4 N2 G1CIRCUIT

RECEPTACLE CONNECTIONS (LOAD)

L3 N1 G1CIRCUIT

VIOLETGRAY/RED

BAREGRAYBLUEREDBLACK

Circuit 1, 2, 3 & 4 Isolated ground receptacles also available.

GREEN/YELLOW

A B C D

Page 51: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

This page intentionally left blank.

Page 52: Haworth Power Power...US configuration has 24” cord per the National Electrical Code (NEC), Canadian configuration has 72” cord per the Canadian Electrical Code (CEC) • Modular

For more information call 800.344.2600 or 616.393.3000.

Haworth is a registered trademark of Haworth, Inc.©Haworth, Inc. 2016 10.16

haworth.com | haworth-europe.com | haworth-asia.com