hanson construction greenacre, nsw 2190 12.0 x 6.0m ... · w3 pvo obscure glass 350 750 1960 pvc 1...

8
ATCO STRUCTURES & LOGISTICS PTY. LTD. 149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132 P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118 E-mail: [email protected] PHONE: FAX: ABN: (07) 3412 8600 (07) 3803 0175 71 083 902 309 Greenacre, NSW 2190 Hanson Construction 150109 12.0 x 6.0m Lunchroom/Amenities - Drawing List Sheet Number Sheet Name Current Revision 00 Title Page E 01 Floor Plan E 02 Elevations E 06 Sales Schedules E View indicative only View indicative only ENERGY REQUIREMENTS: CEILING/ROOF - R2.8 ADDED INSULATION EXTERNAL WALLS - R2.5 ADDED INSULATION INTERNAL WALLS - R2.0 BETWEEN CONDITIONED & UNCONDITIONED AREAS FLOOR - R1.0 ADDED INSULATION WINDOWS GLAZING - SINGLE GLAZED GREY FRAMES - ALUMINIUM GENERAL NOTES: ALL EXHAUST FANS TO BE SELF CLOSING ALL WINDOW FRAMES TO BE WEATHER STRIPPED. ALL GAPS AND CRACKS SEALED. ALL GLAZING TO REFER TO PART J REPORT FOR MINIMUM U & SHGC VALUES. HVAC SYSTEM TO COMPLY WITH ALL PARTS OF PART J5 ARTIFICIAL LIGHTING TO COMPLY WITH ALL PARTS OF PART J6 PLEASE NOTE R VALUES NOTED REPRESENT ADDED INSULATION AND NOT TOTAL R VALUE. NOTE: These Energy Efficiency notes have been included in the Part J DTS Report and override ALL other energy notes. Assessor Name: Matthew Morelli Certificate date: 10.10.18 Dwelling address: Ausnviro Pty Ltd Environmental Rating Specialists Office: 1300 NABERS Melbourne | Sydney | Brisbane | Canberra Head Office: Level 14, 470 Collins Street, Melbourne Lot 1 Honeycomb Drive, Eastern Creek Compliance Method: Deems to Satify (DTS) THE ENDORSED PLANS HAVE BEEN PROVIDED BY THE CLIENT AND ASSESSED USING NCC PARTJ DTS PROVISIONS. Accreditation number: VIC/BDAV/16/1737

Upload: others

Post on 14-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Hanson Construction Greenacre, NSW 2190 12.0 x 6.0m ... · W3 PVO Obscure Glass 350 750 1960 PVC 1 Sales Roof Structure Schedule Roof Structure Comments 2° End to End Roof 611mm

ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

Greenacre, NSW 2190Hanson Construction

150109

12.0 x 6.0m Lunchroom/Amenities

- Drawing ListSheet

Number Sheet NameCurrentRevision

00 Title Page E01 Floor Plan E02 Elevations E06 Sales Schedules E

View indicative only

View indicative only

ENERGY REQUIREMENTS:

CEILING/ROOF - R2.8 ADDED INSULATION

EXTERNAL WALLS - R2.5 ADDED INSULATION

INTERNAL WALLS - R2.0 BETWEEN CONDITIONED & UNCONDITIONED AREAS

FLOOR - R1.0 ADDED INSULATION

WINDOWS GLAZING - SINGLE GLAZED GREYFRAMES - ALUMINIUM

GENERAL NOTES: ALL EXHAUST FANS TO BE SELF CLOSINGALL WINDOW FRAMES TO BE WEATHER STRIPPED.ALL GAPS AND CRACKS SEALED.ALL GLAZING TO REFER TO PART J REPORT FOR MINIMUM U & SHGC VALUES.HVAC SYSTEM TO COMPLY WITH ALL PARTS OF PART J5ARTIFICIAL LIGHTING TO COMPLY WITH ALL PARTS OF PART J6PLEASE NOTE R VALUES NOTED REPRESENT ADDED INSULATION AND NOT TOTAL R VALUE.

NOTE: These Energy Efficiency notes have been included in the Part J DTS Report and override ALL other energy notes.

Assessor Name: Matthew Morelli

Certificate date: 10.10.18Dwelling address:

Ausnviro Pty LtdEnvironmental Rating Specialists

Office: 1300 NABERSMelbourne | Sydney | Brisbane | CanberraHead Office: Level 14, 470 Collins Street,

Melbourne

Lot 1 Honeycomb Drive,Eastern CreekCompliance Method: Deems to Satify (DTS)

THE ENDORSED PLANS HAVE BEEN PROVIDED BY THE CLIENT AND ASSESSED USING NCC PARTJ DTS PROVISIONS.

Accreditation number: VIC/BDAV/16/1737

Page 2: Hanson Construction Greenacre, NSW 2190 12.0 x 6.0m ... · W3 PVO Obscure Glass 350 750 1960 PVC 1 Sales Roof Structure Schedule Roof Structure Comments 2° End to End Roof 611mm

fwfwfw

fw

IPX5

22

22 2

2

2 2

22

2 2

WP

22

2

DSB

POE

02A

02C

02B

02D

A

1 2

B

C

C30030 Stiffened & Cambered Paired Beams

1

7347

86

900

86

1000

86

1000

86

214

86

945

2a2a

Jc

x

D22040

820x

D32040

820x

D32040

820x

D42040

820

x

W3750350

x

W11808900

x

W11808900

x

W21208900

x

W21208900

x

D12040

920

HWS

85 11836 8585

5836

85NORTH

(ASSUMED)16

465

086

2100

85

Covered Verandah & Stairs - By others

5

x

W11808900

2b7

6

M3 M3 M3

85 7047 86 120086

100086

100086

1245 85

8528

3616

428

3685

1200060

00

Ver

anda

h

1800

Floo

r-1

3000

Floo

r-2

3000

2° Roof Pitch

J1

Jb

4

Ja JaM1

M2

WI

333COMMS. CABINET- BY OTHERS200

THIS DRAWING REMAINS THEPROPERTY OF ATCO

STRUCTURES PTY. LTD. IT MAYNOT BE REPRODUCED OR

COPIED WHOLE OR IN PARTWITHOUT WRITTEN AUTHORITY

QUALITY CERTIFIED TO AS/NZSISO 9001:2008 BY SCI-QUAL

INTERNATIONAL REGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

Project No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS IMP. LEVEL

Greenacre, NSW 2190 1 : 100

13/0

5/20

15 1

2:47

:38

PM

EH:\02 Projects\2015\01-January\150109_Hanson Construction_SYD\02 Drawings\150109 RevE.rvt

Hanson Construction12.0 x 6.0m Lunchroom/Amenities

VT

TA

150109 -01

14-1-15

Floor Plan Reg. B Cat. 2

6 2

- Fire fighting equipment supplied & installed by others.- Any 3D views are to be regarded as indicative only.- Draw Wires indicated for Data & Telecom - cable by others.- Comms. Cabinet - By others.- Covered verandah, landings & stairs/railings shown are indicative only

- By others.- The Glazing Calculator for Energy Efficiency has been calculated uponthe North point indicated. Should the final postion vary, the EnergyEfficiency may be compromised, and additional costs / redesign may berequired for compliance.

Notes

1 : 100

Floor Plan1

1 945 x 945 Fibreglass shower cubicle2a WC Suite c/w toilet roll holder2b WC - Ambulant c/w Grabrails, Toilet Roll Holder & Coat Hook3 Hand Basin, Compact, Stainless Steel (Hot & cold flickmixer) w/ mirror4 S/S Insert Sink c/w Flickmixer & Drainers - 1200x4505 Autoboiler - 2.5 litre - BIRKO c/w inbuilt timer6 Coat Hooks on Timber Rail - 1000w7 300mm Wide Timber slatted bench seat - 1000L172 Comms. Cabinet - 600W x 550D x 635H (BY OTHERS)fw Floor WasteHWS 125Ltr Hot water system - mounted externallyJ1 Benchtop c/w splashback & end panels - Laminated - 32mm - Straight

- 600 Deep - 2514 Long - 900 HighJa Base Cabinet - 2 door, 1 shelf x 1000wJb Base Cabinet - 4 Drawer x 450w c/w Cutlery InsertJc Microwave Shelf - 750wWI Plumbing - Water Inlet

Item ListD1 2040 x 920 External Door - Half Glass : Hollow Core MCD2 2040 x 820 External Door - Standard : Hollow Core MCD3 2040 x 820 External Door - Standard : Hollow Core MCD4 2040 x 820 External Door - Standard : Hollow Core MCW1 900 x 1808 Sliding Glass Window - Grey GlassW2 900 x 1208 Sliding Glass Window - Grey GlassW3 350 x 750 Sliding Glass Window - Obscure GlassM1 7.0kW R/C Split System Air ConditionerM2 5.0kW R/C Split System Air ConditionerM3 Wall Mounted Exhaust Fan

EXIT

240V Smoke detector

Distribution Switchboard

External light18W Single Vandalite

36w Single fluorescent light

15amp Single GPO.10amp Double GPO10amp Single GPO

36w Single fluorescent light - IP65 rated

36w Double fluorescent light

10amp GPO - IPX5 rated

Comms. - Draw wire only

Light switchTwo-way light switch

Photo electric light switchSpot light

'F' Type television outlet

Oyster light

Light switch - IPX5 rated

20amp Single GPO

Emergency exit light

Oyster Light - 11W Round Fluro

36w Emergency back-up fluorescent light

POE - Point Of Entry

- Indicates floor mounting- Indicates ceiling mounting

DSB

IPX5

IPX5

WP

PE

Symbol Legend

2

Isolation Switch

PLUMBING - Water Inlet PointPLUMBING - Waste Manifold Outlet Point

Emergency light - Spitfire 10W - battery backup

SALE STRUCTURAL NOTES for Reg. B Cat. 2 - Minimum Design Criteria

Dead and Live Windloads in accordance with the latest version of AS1170.2Wind Region: A or B - Terrain Category: 2Strength Design Wind Speed: Vu = 52m/sServiceability Wind Speed: Vs = 33.8m/sShielding Multiplier: 1.0 Topographic Multiplier: 1.0Earthquake Loads in accordance with the latest version of AS1170.4

WINDOW SPECIFICATIONULS (ULTIMATE) - 2.23kPASLS (SERVICEABILITY) - 0.91kPAWATER PENETRATION - 300PA

Rev Description Date ByD Replaced EXT door hardwares w/ passage

set & dead lock, Replaced windowamplimesh screens w/ Crimsafe typescreens.

16.03.15 VT

E Added half glass c/w screen to D1,Relocated DSB, Added ceiling MTD drawwire conduit, Added Comms. cabinet.

06.05.15 VT

Assessor Name: Matthew Morelli

Certificate date: 10.10.18Dwelling address:

Ausnviro Pty LtdEnvironmental Rating Specialists

Office: 1300 NABERSMelbourne | Sydney | Brisbane | CanberraHead Office: Level 14, 470 Collins Street,

Melbourne

Lot 1 Honeycomb Drive,Eastern CreekCompliance Method: Deems to Satify (DTS)

THE ENDORSED PLANS HAVE BEEN PROVIDED BY THE CLIENT AND ASSESSED USING NCC PARTJ DTS PROVISIONS.

Accreditation number: VIC/BDAV/16/1737

Page 3: Hanson Construction Greenacre, NSW 2190 12.0 x 6.0m ... · W3 PVO Obscure Glass 350 750 1960 PVC 1 Sales Roof Structure Schedule Roof Structure Comments 2° End to End Roof 611mm

12

1 2

FFL

0

Ceiling

2445

GL

-530

A B C

App

rox.

Tra

nspo

rt H

eigh

t

3016

FFL

0

Ceiling

2445

GL

-530

ABC

THIS DRAWING REMAINS THEPROPERTY OF ATCO

STRUCTURES PTY. LTD. IT MAYNOT BE REPRODUCED OR

COPIED WHOLE OR IN PARTWITHOUT WRITTEN AUTHORITY

QUALITY CERTIFIED TO AS/NZSISO 9001:2008 BY SCI-QUAL

INTERNATIONAL REGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

Project No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS IMP. LEVEL

Greenacre, NSW 2190 1 : 100

13/0

5/20

15 1

2:47

:47

PM

EH:\02 Projects\2015\01-January\150109_Hanson Construction_SYD\02 Drawings\150109 RevE.rvt

Hanson Construction12.0 x 6.0m Lunchroom/Amenities

VT

TA

150109 -02

14-1-15

Elevations Reg. B Cat. 2

6 2

1 : 100

Elevation AA

1 : 100

Elevation BB

Maxirib External Cladding

2° End to End Roof

Aluminium Framed Windowsc/w Crimsafe Type Security Screens

Split System Air ConditionerCompressors

Metal Clad External Doorc/w Half Glass + Crimsafe Type Security Screen

150PFC Skid Beams

1 : 100

Elevation DD

1 : 100

Elevation CC

Aluminium Framed WindowsPermanently Vented Open (PVO)c/w Crimsafe Type Security Screens

Rev Description Date ByD Replaced EXT door hardwares w/ passage

set & dead lock, Replaced windowamplimesh screens w/ Crimsafe typescreens.

16.03.15 VT

E Added half glass c/w screen to D1,Relocated DSB, Added ceiling MTD drawwire conduit, Added Comms. cabinet.

06.05.15 VT

Metal Clad External Doors

Assessor Name: Matthew Morelli

Certificate date: 10.10.18Dwelling address:

Ausnviro Pty LtdEnvironmental Rating Specialists

Office: 1300 NABERSMelbourne | Sydney | Brisbane | CanberraHead Office: Level 14, 470 Collins Street,

Melbourne

Lot 1 Honeycomb Drive,Eastern CreekCompliance Method: Deems to Satify (DTS)

THE ENDORSED PLANS HAVE BEEN PROVIDED BY THE CLIENT AND ASSESSED USING NCC PARTJ DTS PROVISIONS.

Accreditation number: VIC/BDAV/16/1737

Page 4: Hanson Construction Greenacre, NSW 2190 12.0 x 6.0m ... · W3 PVO Obscure Glass 350 750 1960 PVC 1 Sales Roof Structure Schedule Roof Structure Comments 2° End to End Roof 611mm

THIS DRAWING REMAINS THEPROPERTY OF ATCO

STRUCTURES PTY. LTD. IT MAYNOT BE REPRODUCED OR

COPIED WHOLE OR IN PARTWITHOUT WRITTEN AUTHORITY

QUALITY CERTIFIED TO AS/NZSISO 9001:2008 BY SCI-QUAL

INTERNATIONAL REGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

Project No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3

ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS IMP. LEVEL

Greenacre, NSW 2190

13/0

5/20

15 1

2:47

:51

PM

EH:\02 Projects\2015\01-January\150109_Hanson Construction_SYD\02 Drawings\150109 RevE.rvt

Hanson Construction12.0 x 6.0m Lunchroom/Amenities

VT

TA

150109 -06

14-1-15

Sales Schedules Reg. B Cat. 2

6 2

Sales Window Schedule

No. Type Glazing Height WidthSill

HeightWindowMoulds Quantity Comments

W1 Sliding XO Grey Glass 900 1808 1000 PVC 3W2 Sliding XO Grey Glass 900 1208 1000 PVC 2W3 PVO Obscure Glass 350 750 1960 PVC 1

Sales Roof Structure ScheduleRoof Structure Comments

2° End to End Roof611mm Ceiling Joist CentresCeiling Joist - SLC7512Insulation - R2.3 Foil Backed Blanket- 95mmLining - Internal - 3.6mm Silver Cloud PlywoodPurlins - LC7512Roof - 0.42mm BMT Superdek Roofing

- Wall ScheduleWall Structure Comments

External Wall - Poly Ply Internal611mm Stud CentresCladding - External - Maxirib - HorizontalFraming - LC7810Insulation - R3.1 Batts - 75mmLining - Internal - 3.6mm Polyester CoatedPlywoodThermal Break between Framing and CladdingInternal Wall - Ply611mm Stud CentresFraming - LC7810Lining - Internal - 3.6mm Polyester CoatedPlywood

* Plumbing FixturesNo. Description Quantity Comments

1 945 x 945 Fibreglass shower cubicle 1 Hot & Cold2a WC Suite c/w toilet roll holder 22b WC - Ambulant c/w Grabrails, Toilet Roll Holder

& Coat Hook1

3 Hand Basin, Compact, Stainless Steel (Hot &cold flickmixer) w/ mirror

3

4 S/S Insert Sink c/w Flickmixer & Drainers -1200x450

1 Hot & Cold

5 Autoboiler - 2.5 litre - BIRKO c/w inbuilt timer 1fw Floor Waste 4

HWS 125Ltr Hot water system - mounted externally 1WI Plumbing - Water Inlet 1 Lighting Fixtures Quantity

1x18W Fluro & Diffuser 31x18W Fluro - IP65 11x36W Fluro & Diffuser 12x36W Fluro & Diffuser 7Switch - IPX5 1Switch - Std 4

- Electrical FixturesDescription Quantity

1x10amp GPO 61x15amp GPO - Autoboil 12x10amp GPO 15Comms. Cabinet - 600W x 550D x 635H (BY OTHERS) 1Draw Wire 5Draw Wire (With Conduit - Ceiling To Floor) - CeilingMounted.

1

Isolation Switch - AC 2Switchboard 1

- CupboardsNo. Description Quantity CommentsJ1 Benchtop c/w splashback & end panels -

Laminated - 32mm - Straight - 600 Deep - 2514Long - 900 High

1

Ja Base Cabinet - 2 door, 1 shelf x 1000w 2Jb Base Cabinet - 4 Drawer x 450w c/w Cutlery

Insert1

Jc Microwave Shelf - 750w 1

Sales Mechanical EquipmentNo. Supplier Description QuantityM1 TCL 7.0kW R/C Split System Air Conditioner 1M2 TCL 5.0kW R/C Split System Air Conditioner 1M3 AIRFLOW Wall Mounted Exhaust Fan 3

- Floor Structure ScheduleFloor Structure Comments

Floor600mm Floor Joist CentresCovering - 2.0mm Vinyl 150mm Coved

in wet areas onlyFloor Joists - LC7512Flooring - 17mm F11 T&G PlywoodInsulation - Under Floor - R2.1 Heavy Duty FoilFaced Batts

Wall Height2445

Manufacturing Structural Members

DescriptionMember

SizeBack to

BackSkid Beams c/w Retractable Lifters 150PFC 2000Paired Beams C30030

Stiffened &Cambered

Sales Door Schedule

No. Panel Height WidthHandleType

HardwareSet

PWDCompliant Closer

PanicBar

C/BJamb

TimberJamb Security Quantity Comments

D1 Half Glass : Hollow Core MC 2040 920 Lever Passage Yes Yes No Yes No Dead Lock,Crimsafe Type

Security Screen

1 E/E seals, LaminatedGrey Glass

D2 Standard : Hollow Core MC 2040 820 Standard Passage No Yes No Yes No Dead Lock,Indicator bolt

1 E/E seals, Door Grille

D3 Standard : Hollow Core MC 2040 820 Standard Passage No Yes No Yes No Dead Lock,Indicator bolt

2 E/E seals, Door Grille

D4 Standard : Hollow Core MC 2040 820 Lever Passage No Yes No Yes No Dead Lock,Indicator bolt

1 E/E seals, Door Grille

- Security FeaturesDescription Size Quantity

Crimsafe Type Security Screen 350 x 750. 1Crimsafe Type Security Screen 900 x 1200. 2Crimsafe Type Security Screen 900 x 1800. 3

Rev Description Date ByD Replaced EXT door hardwares w/ passage

set & dead lock, Replaced windowamplimesh screens w/ Crimsafe typescreens.

16.03.15 VT

E Added half glass c/w screen to D1,Relocated DSB, Added ceiling MTD drawwire conduit, Added Comms. cabinet.

06.05.15 VT

Assessor Name: Matthew Morelli

Certificate date: 10.10.18Dwelling address:

Ausnviro Pty LtdEnvironmental Rating Specialists

Office: 1300 NABERSMelbourne | Sydney | Brisbane | CanberraHead Office: Level 14, 470 Collins Street,

Melbourne

Lot 1 Honeycomb Drive,Eastern CreekCompliance Method: Deems to Satify (DTS)

THE ENDORSED PLANS HAVE BEEN PROVIDED BY THE CLIENT AND ASSESSED USING NCC PARTJ DTS PROVISIONS.

Accreditation number: VIC/BDAV/16/1737

Page 5: Hanson Construction Greenacre, NSW 2190 12.0 x 6.0m ... · W3 PVO Obscure Glass 350 750 1960 PVC 1 Sales Roof Structure Schedule Roof Structure Comments 2° End to End Roof 611mm

ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

Greenacre, NSW 2190Hanson Construction

150108

12.0 x 6.0m Office Complex

- Drawing ListSheet

Number Sheet NameCurrentRevision

00 Title Page E01 Floor Plan E02 Elevations E06 Sales Schedules E

View indicative only

View indicative only

ENERGY REQUIREMENTS:

CEILING/ROOF - R2.8 ADDED INSULATION

EXTERNAL WALLS - R2.5 ADDED INSULATION

INTERNAL WALLS - R2.0 BETWEEN CONDITIONED & UNCONDITIONED AREAS

FLOOR - R1.0 ADDED INSULATION

WINDOWS GLAZING - SINGLE GLAZED GREYFRAMES - ALUMINIUM

GENERAL NOTES: ALL EXHAUST FANS TO BE SELF CLOSINGALL WINDOW FRAMES TO BE WEATHER STRIPPED.ALL GAPS AND CRACKS SEALED.ALL GLAZING TO REFER TO PART J REPORT FOR MINIMUM U & SHGC VALUES.HVAC SYSTEM TO COMPLY WITH ALL PARTS OF PART J5ARTIFICIAL LIGHTING TO COMPLY WITH ALL PARTS OF PART J6PLEASE NOTE R VALUES NOTED REPRESENT ADDED INSULATION AND NOT TOTAL R VALUE.

NOTE: These Energy Efficiency notes have been included in the Part J DTS Report and override ALL other energy notes.

Assessor Name: Matthew Morelli

Certificate date: 10.10.18Dwelling address:

Ausnviro Pty LtdEnvironmental Rating Specialists

Office: 1300 NABERSMelbourne | Sydney | Brisbane | CanberraHead Office: Level 14, 470 Collins Street,

Melbourne

Lot 1 Honeycomb Drive,Eastern CreekCompliance Method: Deems to Satify (DTS)

THE ENDORSED PLANS HAVE BEEN PROVIDED BY THE CLIENT AND ASSESSED USING NCC PARTJ DTS PROVISIONS.

Accreditation number: VIC/BDAV/16/1737

Page 6: Hanson Construction Greenacre, NSW 2190 12.0 x 6.0m ... · W3 PVO Obscure Glass 350 750 1960 PVC 1 Sales Roof Structure Schedule Roof Structure Comments 2° End to End Roof 611mm

fw

222222

222222

22

2

2

2

2 2

2 2 2

2

2

2

PE

DSB

POE

02A

02C

02B

02D

A

1 2

B

C

12000

Verandah

1800

6000

Ver

anda

h

1800

96 4000 98 5628 98 2000 96

9658

2491

Floo

r-1

3000

Floo

r-2

3000

MEETING

x

D22040

920

x

W1600600x

W31808900

x

W31808900

x

W31808900

x

W31808900

x

W2908900

4

J15Jg

Je

WI

1

9128

2417

628

2496

23

UNISEXPWD WC

M1

x

D32040

920

RAMP (1:14) - By others

Covered verandah, landings,stairs/railings - TYP. - By others

OFFICE

KITCHEN

7 7

7 7

J2

Jf

PRINTER SPACE

Jc Jc

Jb Ja

1800 2028 1800

RECEPTION

8

NORTH(ASSUMED)

2° R

oof P

itch

C30030 Stiffened & Cambered.Paired Beams (Concealed) - TYP.

Partition walls- 1200H (TYP.)

COMMS. CABINET- BY OTHERS

MONITOR SPACE

6

STORAGE

96 4000 98 7726 96

J2

Jc Jc

Ram

p

1240

Stairs

900

Sta

irs

900

x

W31808900

M2M3

x

D12040

920

2126

9836

00THIS DRAWING REMAINS THE

PROPERTY OF ATCOSTRUCTURES PTY. LTD. IT MAY

NOT BE REPRODUCED ORCOPIED WHOLE OR IN PART

WITHOUT WRITTEN AUTHORITY

QUALITY CERTIFIED TO AS/NZSISO 9001:2008 BY SCI-QUAL

INTERNATIONAL REGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

Project No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3

ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS IMP. LEVEL

Greenacre, NSW 2190 1 : 100

13/0

5/20

15 1

2:45

:48

PM

EH:\02 Projects\2015\01-January\150108_Hanson Construction_SYD\02 Drawings\150108 RevE.rvt

Hanson Construction12.0 x 6.0m Office Complex

AAC

VT

150108 -01

12.01.15

Floor Plan Reg. B Cat. 2

5 2

- Fire fighting equipment supplied & installed by others.- Any 3D views are to be regarded as indicative only.- Draw Wires indicated for Data & Telecom - cable by others.- Comms. Cabinet - By others.- Skirtings around building are indicative only - By ATCO operations.- Covered verandah, landings, stairs/railings, ramp & tactile indicators shown

are indicative only - By others.- The Glazing Calculator for Energy Efficiency has been calculated upon the Northpoint indicated. Should the final postion vary, the Energy Efficiency may becompromised, and additional costs / redesign may be required for compliance.

Notes

1 : 100

Floor Plan1

1 Toilet Suite, Disabled c/w Grab Rails & Backrest2 Disabled Hand Basin - c/w Oversized Mirror Over3 Handbasin - Disabled Shelf4 S/S Insert Sink c/w Flickmixer & Drainer - 900x4505 Autoboiler - 2.5 litre - BIRKO c/w inbuilt timer6 Drinking Water Fountain Bubbler (BY OTHERS)7 Workstation - 1800x1800 (BY OTHERS)8 MeetingTable - 3000x1500 (BY OTHERS)fw Floor WasteJ1 Benchtop c/w splashback & end panels - Laminated -

32mm - Straight - 600 Deep - 2000 Long - 900 HighJ2 Benchtop c/w end panels - Laminated - 32mm - Straight

- 450 Deep - 1764 Long - 1200 HighJa Base Cabinet - 2 door, 1 shelf x 900wJb Base Cabinet - 4 Drawer x 400w c/w Cutlery InsertJc Base Cabinet - 2 door, 1 shelf x 850wJe Microwave Shelf - 600wJf Overhead Cupboard - 1 Door & 1 Shelf x 450 wideJg Overhead Cupboard - 2 Door & 1 Shelf x 900 wideWI Plumbing - Water Inlet

Item ListD1 6.38mm Grey Laminated Glass c/w

'Crimsafe Type' Security Screen.Shop Front Door

D2 2040 x 920 External Door - Standard : Hollow Core MCD3 2040 x 920 Internal Door - Standard : Hollow CoreW1 600 x 600 Sliding Glass Window - Obscure GlassW2 900 x 908 Sliding Glass Window - Grey GlassW3 900 x 1808 Sliding Glass Window - Grey GlassM1 Wall Mounted Exhaust FanM2 7.0kW R/C Split System Air ConditionerM3 5.0kW R/C Split System Air Conditioner

240V Smoke detector

Distribution Switchboard

36w Single fluorescent light

15amp Single GPO.10amp Double GPO10amp Single GPO

36w Single fluorescent light - IP65 rated

36w Double fluorescent light

10amp GPO - IPX5 rated

Comms. - Draw wire only

Light switchTwo-way light switch

'F' Type television outlet

Light switch - IPX5 rated

20amp Single GPO

Emergency exit light

36w Emergency back-up fluorescent light

POE - Point Of Entry

- Indicates floor mounting- Indicates ceiling mounting

DSB

IPX5

IPX5

WP

EXIT

Symbol Legend

2

Isolation Switch

External light18W Single Vandalite

Photo electric light switchSpot light

Oyster light

Oyster Light - 11W Round Fluro

PE

PLUMBING - Water Inlet PointPLUMBING - Waste Manifold Outlet Point

Emergency light - Spitfire 10W - battery backup

SALE STRUCTURAL NOTES for Reg. B Cat. 2 - Minimum Design Criteria

Dead and Live Windloads in accordance with the latest version of AS1170.2Wind Region: A or B - Terrain Category: 2Strength Design Wind Speed: Vu = 52m/sServiceability Wind Speed: Vs = 33.8m/sShielding Multiplier: 1.0 Topographic Multiplier: 1.0Earthquake Loads in accordance with the latest version of AS1170.4

WINDOW SPECIFICATIONULS (ULTIMATE) - 2.23kPASLS (SERVICEABILITY) - 0.91kPAWATER PENETRATION - 300PA

Rev Description Date ByD Replaced EXT door hardwares w/ passage

set & dead lock, Replaced windowamplimesh screens w/ Crimsafe typescreens.

16.03.15 VT

E Replaced D1 w/ Shop Front type c/wscreen, Relocated DSB & PE cell, Addedceiling MTD draw wire conduit,Reconfigured Comms. cabinet.

06.05.15 VT

Assessor Name: Matthew Morelli

Certificate date: 10.10.18Dwelling address:

Ausnviro Pty LtdEnvironmental Rating Specialists

Office: 1300 NABERSMelbourne | Sydney | Brisbane | CanberraHead Office: Level 14, 470 Collins Street,

Melbourne

Lot 1 Honeycomb Drive,Eastern CreekCompliance Method: Deems to Satify (DTS)

THE ENDORSED PLANS HAVE BEEN PROVIDED BY THE CLIENT AND ASSESSED USING NCC PARTJ DTS PROVISIONS.

Accreditation number: VIC/BDAV/16/1737

Page 7: Hanson Construction Greenacre, NSW 2190 12.0 x 6.0m ... · W3 PVO Obscure Glass 350 750 1960 PVC 1 Sales Roof Structure Schedule Roof Structure Comments 2° End to End Roof 611mm

12

1 2

FFL

0

Ceiling

2710

GL

-530

A B C

App

rox.

Tra

nspo

rt H

eigh

t

3784

200

(App

rox.

Par

apet

Hei

ght)

FFL

0

Ceiling

2710

GL

-530

ABC

THIS DRAWING REMAINS THEPROPERTY OF ATCO

STRUCTURES PTY. LTD. IT MAYNOT BE REPRODUCED OR

COPIED WHOLE OR IN PARTWITHOUT WRITTEN AUTHORITY

QUALITY CERTIFIED TO AS/NZSISO 9001:2008 BY SCI-QUAL

INTERNATIONAL REGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

Project No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS IMP. LEVEL

Greenacre, NSW 2190 1 : 100

13/0

5/20

15 1

2:46

:01

PM

EH:\02 Projects\2015\01-January\150108_Hanson Construction_SYD\02 Drawings\150108 RevE.rvt

Hanson Construction12.0 x 6.0m Office Complex

AAC

VT

150108 -02

12.01.15

Elevations Reg. B Cat. 2

5 2

1 : 100

Elevation AA

1 : 100

Elevation BB

Maxirib External Cladding

2° Skillion Roof

Aluminium Framed WindowPermanently Vented Open (PVO)c/w Crimsafe Type Security Screen

Split System Air ConditionerCompressors

Commercial Shop Front External Doorc/w Crimsafe Type Security Screen

150PFC Skid Beams(In Skirtings)

1 : 100

Elevation DD

1 : 100

Elevation CC

Aluminium Framed Windowsc/w Crimsafe Type Security Screens

Scyon Matrix External Cladding

Metal Clad External Door

Rev Description Date ByD Replaced EXT door hardwares w/ passage

set & dead lock, Replaced windowamplimesh screens w/ Crimsafe typescreens.

16.03.15 VT

E Replaced D1 w/ Shop Front type c/wscreen, Relocated DSB & PE cell, Addedceiling MTD draw wire conduit,Reconfigured Comms. cabinet.

06.05.15 VT

Assessor Name: Matthew Morelli

Certificate date: 10.10.18Dwelling address:

Ausnviro Pty LtdEnvironmental Rating Specialists

Office: 1300 NABERSMelbourne | Sydney | Brisbane | CanberraHead Office: Level 14, 470 Collins Street,

Melbourne

Lot 1 Honeycomb Drive,Eastern CreekCompliance Method: Deems to Satify (DTS)

THE ENDORSED PLANS HAVE BEEN PROVIDED BY THE CLIENT AND ASSESSED USING NCC PARTJ DTS PROVISIONS.

Accreditation number: VIC/BDAV/16/1737

Page 8: Hanson Construction Greenacre, NSW 2190 12.0 x 6.0m ... · W3 PVO Obscure Glass 350 750 1960 PVC 1 Sales Roof Structure Schedule Roof Structure Comments 2° End to End Roof 611mm

THIS DRAWING REMAINS THEPROPERTY OF ATCO

STRUCTURES PTY. LTD. IT MAYNOT BE REPRODUCED OR

COPIED WHOLE OR IN PARTWITHOUT WRITTEN AUTHORITY

QUALITY CERTIFIED TO AS/NZSISO 9001:2008 BY SCI-QUAL

INTERNATIONAL REGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

Project No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS IMP. LEVEL

Greenacre, NSW 2190

13/0

5/20

15 1

2:46

:05

PM

EH:\02 Projects\2015\01-January\150108_Hanson Construction_SYD\02 Drawings\150108 RevE.rvt

Hanson Construction12.0 x 6.0m Office Complex

AAC

VT

150108 -06

12.01.15

Sales Schedules Reg. B Cat. 2

5 2

Sales Window Schedule

No. Type Glazing Height WidthSill

HeightWindowMoulds Quantity Comments

W1 PVO Obscure Glass 600 600 1700 Timber 1W2 Sliding XO Grey Glass 900 908 1200 Timber 1W3 Sliding XO Grey Glass 900 1808 1200 Timber 5

Sales Roof Structure ScheduleRoof Structure Comments

2° Skillion Roof (Complexing On Site - By ATCO operations)600mm Ceiling Joist CentresCeiling Joist - SLC7512Insulation - R2.3 Foil Backed Blanket- 95mmLining - Internal - 10mm Plasterboard Painted FinishPurlins - LC7512Roof - 0.42mm BMT Superdek Roofing

- Wall ScheduleWall Structure Comments

External Wall - Plasterboard Internal600mm Stud CentresCladding - 8mm Matrix Cladding As IndicatedCladding - External - Maxirib - Horizontal As IndicatedFraming - LC7810Insulation - R3.1 Batts - 75mmInsulation - Sisalation Wall WrapLining - Internal - 10mm Plasterboard Painted FinishThermal Break between Framing and CladdingInternal Wall - Plasterboard600mm Stud CentresFraming - LC7810Lining - Internal - 10mm Plasterboard Painted Finish

* Plumbing FixturesNo. Description Quantity Comments

1 Toilet Suite, Disabled c/w Grab Rails & Backrest 12 Disabled Hand Basin - c/w Oversized Mirror Over 1 Cold Only3 Handbasin - Disabled Shelf 14 S/S Insert Sink c/w Flickmixer & Drainer - 900x450 1 Cold Only5 Autoboiler - 2.5 litre - BIRKO c/w inbuilt timer 16 Drinking Water Fountain Bubbler (BY OTHERS) 1fw Floor Waste 1WI Plumbing - Water Inlet 1

Lighting Fixtures Quantity1x36W Fluro & Diffuser 12x36W Fluro & Electronic Ballast Diffuser 9Photo Electric Cell 1Single Vandalite - Wall Mounted 2Switch - Std 3

- Electrical FixturesDescription Quantity

1x10amp GPO 21x15amp GPO - Autoboil 12x10amp GPO 242x10amp GPO - Floor Mounted 1Comms. Cabinet - 600W x 550D x 635H (BY OTHERS) 1Draw Wire 18Draw Wire (With Conduit - Ceiling To Floor) - CeilingMounted.

1

Draw Wire - Floor Mounted 1Isolation Switch - AC 2Switchboard 1

- FurnitureNo. Description Quantity Comments

7 Workstation - 1800x1800 (BY OTHERS) 48 MeetingTable - 3000x1500 (BY OTHERS) 1

- CupboardsNo. Description Quantity CommentsJ1 Benchtop c/w splashback & end panels -

Laminated - 32mm - Straight - 600 Deep - 2000Long - 900 High

1

J2 Benchtop c/w end panels - Laminated - 32mm -Straight - 450 Deep - 1764 Long - 1200 High

2

Ja Base Cabinet - 2 door, 1 shelf x 900w 1Jb Base Cabinet - 4 Drawer x 400w c/w Cutlery Insert 1Jc Base Cabinet - 2 door, 1 shelf x 850w 4Je Microwave Shelf - 600w 1Jf Overhead Cupboard - 1 Door & 1 Shelf x 450 wide 1Jg Overhead Cupboard - 2 Door & 1 Shelf x 900 wide 1

Sales Mechanical EquipmentNo. Supplier Description QuantityM1 AIRFLOW Wall Mounted Exhaust Fan 1M2 TCL 7.0kW R/C Split System Air Conditioner 1M3 TCL 5.0kW R/C Split System Air Conditioner 1

- Floor Structure ScheduleFloor Structure Comments

Floor600mm Floor Joist CentresCovering - 2.0mm Non-Slip Vinyl - Unisex PWDWC Area Only

150mm Coved

Covering - 2.0mm VinylFloor Joists - LC7512Flooring - 17mm F11 T&G PlywoodInsulation - Under Floor - R2.1 Heavy Duty FoilFaced Batts

Wall Height2710

- Security FeaturesDescription Size Quantity

Crimsafe Type Security Screen 600 x 600. 1Crimsafe Type Security Screen 900 x 900. 1Crimsafe Type Security Screen 900 x 1800. 5

Manufacturing Structural Members

DescriptionMember

SizeBack to

BackSkid Beams c/w Retractable Lifters 150PFC 2000Paired Beams (Concealed) - TYP. C30030

Stiffened &Cambered.

Sales Door Schedule

No. Panel Height WidthHandleType

HardwareSet

PWDCompliant Closer

PanicBar

C/BJamb

TimberJamb Security Quantity Comments

D1 Shop Front Door 2040 920 Push/PullHandle

Entrance Yes Yes Crimsafe TypeSecurity Screen

1 E/E seals, LaminatedGrey Glass

D2 Standard : Hollow Core MC 2040 920 Lever Passage Yes Yes No No Yes Dead Lock,Indicator bolt

1 E/E & weather seals

D3 Standard : Hollow Core 2040 920 Lever Passage Yes No No No Yes 1

Rev Description Date ByD Replaced EXT door hardwares w/ passage

set & dead lock, Replaced windowamplimesh screens w/ Crimsafe typescreens.

16.03.15 VT

E Replaced D1 w/ Shop Front type c/wscreen, Relocated DSB & PE cell, Addedceiling MTD draw wire conduit,Reconfigured Comms. cabinet.

06.05.15 VT

Assessor Name: Matthew Morelli

Certificate date: 10.10.18Dwelling address:

Ausnviro Pty LtdEnvironmental Rating Specialists

Office: 1300 NABERSMelbourne | Sydney | Brisbane | CanberraHead Office: Level 14, 470 Collins Street,

Melbourne

Lot 1 Honeycomb Drive,Eastern CreekCompliance Method: Deems to Satify (DTS)

THE ENDORSED PLANS HAVE BEEN PROVIDED BY THE CLIENT AND ASSESSED USING NCC PARTJ DTS PROVISIONS.

Accreditation number: VIC/BDAV/16/1737