ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
Greenacre, NSW 2190Hanson Construction
150109
12.0 x 6.0m Lunchroom/Amenities
- Drawing ListSheet
Number Sheet NameCurrentRevision
00 Title Page E01 Floor Plan E02 Elevations E06 Sales Schedules E
View indicative only
View indicative only
ENERGY REQUIREMENTS:
CEILING/ROOF - R2.8 ADDED INSULATION
EXTERNAL WALLS - R2.5 ADDED INSULATION
INTERNAL WALLS - R2.0 BETWEEN CONDITIONED & UNCONDITIONED AREAS
FLOOR - R1.0 ADDED INSULATION
WINDOWS GLAZING - SINGLE GLAZED GREYFRAMES - ALUMINIUM
GENERAL NOTES: ALL EXHAUST FANS TO BE SELF CLOSINGALL WINDOW FRAMES TO BE WEATHER STRIPPED.ALL GAPS AND CRACKS SEALED.ALL GLAZING TO REFER TO PART J REPORT FOR MINIMUM U & SHGC VALUES.HVAC SYSTEM TO COMPLY WITH ALL PARTS OF PART J5ARTIFICIAL LIGHTING TO COMPLY WITH ALL PARTS OF PART J6PLEASE NOTE R VALUES NOTED REPRESENT ADDED INSULATION AND NOT TOTAL R VALUE.
NOTE: These Energy Efficiency notes have been included in the Part J DTS Report and override ALL other energy notes.
Assessor Name: Matthew Morelli
Certificate date: 10.10.18Dwelling address:
Ausnviro Pty LtdEnvironmental Rating Specialists
Office: 1300 NABERSMelbourne | Sydney | Brisbane | CanberraHead Office: Level 14, 470 Collins Street,
Melbourne
Lot 1 Honeycomb Drive,Eastern CreekCompliance Method: Deems to Satify (DTS)
THE ENDORSED PLANS HAVE BEEN PROVIDED BY THE CLIENT AND ASSESSED USING NCC PARTJ DTS PROVISIONS.
Accreditation number: VIC/BDAV/16/1737
fwfwfw
fw
IPX5
22
22 2
2
2 2
22
2 2
WP
22
2
DSB
POE
02A
02C
02B
02D
A
1 2
B
C
C30030 Stiffened & Cambered Paired Beams
1
7347
86
900
86
1000
86
1000
86
214
86
945
2a2a
Jc
x
D22040
820x
D32040
820x
D32040
820x
D42040
820
x
W3750350
x
W11808900
x
W11808900
x
W21208900
x
W21208900
x
D12040
920
HWS
85 11836 8585
5836
85NORTH
(ASSUMED)16
465
086
2100
85
Covered Verandah & Stairs - By others
5
x
W11808900
2b7
6
M3 M3 M3
85 7047 86 120086
100086
100086
1245 85
8528
3616
428
3685
1200060
00
Ver
anda
h
1800
Floo
r-1
3000
Floo
r-2
3000
2° Roof Pitch
J1
Jb
4
Ja JaM1
M2
WI
333COMMS. CABINET- BY OTHERS200
THIS DRAWING REMAINS THEPROPERTY OF ATCO
STRUCTURES PTY. LTD. IT MAYNOT BE REPRODUCED OR
COPIED WHOLE OR IN PARTWITHOUT WRITTEN AUTHORITY
QUALITY CERTIFIED TO AS/NZSISO 9001:2008 BY SCI-QUAL
INTERNATIONAL REGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
Project No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS IMP. LEVEL
Greenacre, NSW 2190 1 : 100
13/0
5/20
15 1
2:47
:38
PM
EH:\02 Projects\2015\01-January\150109_Hanson Construction_SYD\02 Drawings\150109 RevE.rvt
Hanson Construction12.0 x 6.0m Lunchroom/Amenities
VT
TA
150109 -01
14-1-15
Floor Plan Reg. B Cat. 2
6 2
- Fire fighting equipment supplied & installed by others.- Any 3D views are to be regarded as indicative only.- Draw Wires indicated for Data & Telecom - cable by others.- Comms. Cabinet - By others.- Covered verandah, landings & stairs/railings shown are indicative only
- By others.- The Glazing Calculator for Energy Efficiency has been calculated uponthe North point indicated. Should the final postion vary, the EnergyEfficiency may be compromised, and additional costs / redesign may berequired for compliance.
Notes
1 : 100
Floor Plan1
1 945 x 945 Fibreglass shower cubicle2a WC Suite c/w toilet roll holder2b WC - Ambulant c/w Grabrails, Toilet Roll Holder & Coat Hook3 Hand Basin, Compact, Stainless Steel (Hot & cold flickmixer) w/ mirror4 S/S Insert Sink c/w Flickmixer & Drainers - 1200x4505 Autoboiler - 2.5 litre - BIRKO c/w inbuilt timer6 Coat Hooks on Timber Rail - 1000w7 300mm Wide Timber slatted bench seat - 1000L172 Comms. Cabinet - 600W x 550D x 635H (BY OTHERS)fw Floor WasteHWS 125Ltr Hot water system - mounted externallyJ1 Benchtop c/w splashback & end panels - Laminated - 32mm - Straight
- 600 Deep - 2514 Long - 900 HighJa Base Cabinet - 2 door, 1 shelf x 1000wJb Base Cabinet - 4 Drawer x 450w c/w Cutlery InsertJc Microwave Shelf - 750wWI Plumbing - Water Inlet
Item ListD1 2040 x 920 External Door - Half Glass : Hollow Core MCD2 2040 x 820 External Door - Standard : Hollow Core MCD3 2040 x 820 External Door - Standard : Hollow Core MCD4 2040 x 820 External Door - Standard : Hollow Core MCW1 900 x 1808 Sliding Glass Window - Grey GlassW2 900 x 1208 Sliding Glass Window - Grey GlassW3 350 x 750 Sliding Glass Window - Obscure GlassM1 7.0kW R/C Split System Air ConditionerM2 5.0kW R/C Split System Air ConditionerM3 Wall Mounted Exhaust Fan
EXIT
240V Smoke detector
Distribution Switchboard
External light18W Single Vandalite
36w Single fluorescent light
15amp Single GPO.10amp Double GPO10amp Single GPO
36w Single fluorescent light - IP65 rated
36w Double fluorescent light
10amp GPO - IPX5 rated
Comms. - Draw wire only
Light switchTwo-way light switch
Photo electric light switchSpot light
'F' Type television outlet
Oyster light
Light switch - IPX5 rated
20amp Single GPO
Emergency exit light
Oyster Light - 11W Round Fluro
36w Emergency back-up fluorescent light
POE - Point Of Entry
- Indicates floor mounting- Indicates ceiling mounting
DSB
IPX5
IPX5
WP
PE
Symbol Legend
2
Isolation Switch
PLUMBING - Water Inlet PointPLUMBING - Waste Manifold Outlet Point
Emergency light - Spitfire 10W - battery backup
SALE STRUCTURAL NOTES for Reg. B Cat. 2 - Minimum Design Criteria
Dead and Live Windloads in accordance with the latest version of AS1170.2Wind Region: A or B - Terrain Category: 2Strength Design Wind Speed: Vu = 52m/sServiceability Wind Speed: Vs = 33.8m/sShielding Multiplier: 1.0 Topographic Multiplier: 1.0Earthquake Loads in accordance with the latest version of AS1170.4
WINDOW SPECIFICATIONULS (ULTIMATE) - 2.23kPASLS (SERVICEABILITY) - 0.91kPAWATER PENETRATION - 300PA
Rev Description Date ByD Replaced EXT door hardwares w/ passage
set & dead lock, Replaced windowamplimesh screens w/ Crimsafe typescreens.
16.03.15 VT
E Added half glass c/w screen to D1,Relocated DSB, Added ceiling MTD drawwire conduit, Added Comms. cabinet.
06.05.15 VT
Assessor Name: Matthew Morelli
Certificate date: 10.10.18Dwelling address:
Ausnviro Pty LtdEnvironmental Rating Specialists
Office: 1300 NABERSMelbourne | Sydney | Brisbane | CanberraHead Office: Level 14, 470 Collins Street,
Melbourne
Lot 1 Honeycomb Drive,Eastern CreekCompliance Method: Deems to Satify (DTS)
THE ENDORSED PLANS HAVE BEEN PROVIDED BY THE CLIENT AND ASSESSED USING NCC PARTJ DTS PROVISIONS.
Accreditation number: VIC/BDAV/16/1737
12
1 2
FFL
0
Ceiling
2445
GL
-530
A B C
App
rox.
Tra
nspo
rt H
eigh
t
3016
FFL
0
Ceiling
2445
GL
-530
ABC
THIS DRAWING REMAINS THEPROPERTY OF ATCO
STRUCTURES PTY. LTD. IT MAYNOT BE REPRODUCED OR
COPIED WHOLE OR IN PARTWITHOUT WRITTEN AUTHORITY
QUALITY CERTIFIED TO AS/NZSISO 9001:2008 BY SCI-QUAL
INTERNATIONAL REGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
Project No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS IMP. LEVEL
Greenacre, NSW 2190 1 : 100
13/0
5/20
15 1
2:47
:47
PM
EH:\02 Projects\2015\01-January\150109_Hanson Construction_SYD\02 Drawings\150109 RevE.rvt
Hanson Construction12.0 x 6.0m Lunchroom/Amenities
VT
TA
150109 -02
14-1-15
Elevations Reg. B Cat. 2
6 2
1 : 100
Elevation AA
1 : 100
Elevation BB
Maxirib External Cladding
2° End to End Roof
Aluminium Framed Windowsc/w Crimsafe Type Security Screens
Split System Air ConditionerCompressors
Metal Clad External Doorc/w Half Glass + Crimsafe Type Security Screen
150PFC Skid Beams
1 : 100
Elevation DD
1 : 100
Elevation CC
Aluminium Framed WindowsPermanently Vented Open (PVO)c/w Crimsafe Type Security Screens
Rev Description Date ByD Replaced EXT door hardwares w/ passage
set & dead lock, Replaced windowamplimesh screens w/ Crimsafe typescreens.
16.03.15 VT
E Added half glass c/w screen to D1,Relocated DSB, Added ceiling MTD drawwire conduit, Added Comms. cabinet.
06.05.15 VT
Metal Clad External Doors
Assessor Name: Matthew Morelli
Certificate date: 10.10.18Dwelling address:
Ausnviro Pty LtdEnvironmental Rating Specialists
Office: 1300 NABERSMelbourne | Sydney | Brisbane | CanberraHead Office: Level 14, 470 Collins Street,
Melbourne
Lot 1 Honeycomb Drive,Eastern CreekCompliance Method: Deems to Satify (DTS)
THE ENDORSED PLANS HAVE BEEN PROVIDED BY THE CLIENT AND ASSESSED USING NCC PARTJ DTS PROVISIONS.
Accreditation number: VIC/BDAV/16/1737
THIS DRAWING REMAINS THEPROPERTY OF ATCO
STRUCTURES PTY. LTD. IT MAYNOT BE REPRODUCED OR
COPIED WHOLE OR IN PARTWITHOUT WRITTEN AUTHORITY
QUALITY CERTIFIED TO AS/NZSISO 9001:2008 BY SCI-QUAL
INTERNATIONAL REGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
Project No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3
ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS IMP. LEVEL
Greenacre, NSW 2190
13/0
5/20
15 1
2:47
:51
PM
EH:\02 Projects\2015\01-January\150109_Hanson Construction_SYD\02 Drawings\150109 RevE.rvt
Hanson Construction12.0 x 6.0m Lunchroom/Amenities
VT
TA
150109 -06
14-1-15
Sales Schedules Reg. B Cat. 2
6 2
Sales Window Schedule
No. Type Glazing Height WidthSill
HeightWindowMoulds Quantity Comments
W1 Sliding XO Grey Glass 900 1808 1000 PVC 3W2 Sliding XO Grey Glass 900 1208 1000 PVC 2W3 PVO Obscure Glass 350 750 1960 PVC 1
Sales Roof Structure ScheduleRoof Structure Comments
2° End to End Roof611mm Ceiling Joist CentresCeiling Joist - SLC7512Insulation - R2.3 Foil Backed Blanket- 95mmLining - Internal - 3.6mm Silver Cloud PlywoodPurlins - LC7512Roof - 0.42mm BMT Superdek Roofing
- Wall ScheduleWall Structure Comments
External Wall - Poly Ply Internal611mm Stud CentresCladding - External - Maxirib - HorizontalFraming - LC7810Insulation - R3.1 Batts - 75mmLining - Internal - 3.6mm Polyester CoatedPlywoodThermal Break between Framing and CladdingInternal Wall - Ply611mm Stud CentresFraming - LC7810Lining - Internal - 3.6mm Polyester CoatedPlywood
* Plumbing FixturesNo. Description Quantity Comments
1 945 x 945 Fibreglass shower cubicle 1 Hot & Cold2a WC Suite c/w toilet roll holder 22b WC - Ambulant c/w Grabrails, Toilet Roll Holder
& Coat Hook1
3 Hand Basin, Compact, Stainless Steel (Hot &cold flickmixer) w/ mirror
3
4 S/S Insert Sink c/w Flickmixer & Drainers -1200x450
1 Hot & Cold
5 Autoboiler - 2.5 litre - BIRKO c/w inbuilt timer 1fw Floor Waste 4
HWS 125Ltr Hot water system - mounted externally 1WI Plumbing - Water Inlet 1 Lighting Fixtures Quantity
1x18W Fluro & Diffuser 31x18W Fluro - IP65 11x36W Fluro & Diffuser 12x36W Fluro & Diffuser 7Switch - IPX5 1Switch - Std 4
- Electrical FixturesDescription Quantity
1x10amp GPO 61x15amp GPO - Autoboil 12x10amp GPO 15Comms. Cabinet - 600W x 550D x 635H (BY OTHERS) 1Draw Wire 5Draw Wire (With Conduit - Ceiling To Floor) - CeilingMounted.
1
Isolation Switch - AC 2Switchboard 1
- CupboardsNo. Description Quantity CommentsJ1 Benchtop c/w splashback & end panels -
Laminated - 32mm - Straight - 600 Deep - 2514Long - 900 High
1
Ja Base Cabinet - 2 door, 1 shelf x 1000w 2Jb Base Cabinet - 4 Drawer x 450w c/w Cutlery
Insert1
Jc Microwave Shelf - 750w 1
Sales Mechanical EquipmentNo. Supplier Description QuantityM1 TCL 7.0kW R/C Split System Air Conditioner 1M2 TCL 5.0kW R/C Split System Air Conditioner 1M3 AIRFLOW Wall Mounted Exhaust Fan 3
- Floor Structure ScheduleFloor Structure Comments
Floor600mm Floor Joist CentresCovering - 2.0mm Vinyl 150mm Coved
in wet areas onlyFloor Joists - LC7512Flooring - 17mm F11 T&G PlywoodInsulation - Under Floor - R2.1 Heavy Duty FoilFaced Batts
Wall Height2445
Manufacturing Structural Members
DescriptionMember
SizeBack to
BackSkid Beams c/w Retractable Lifters 150PFC 2000Paired Beams C30030
Stiffened &Cambered
Sales Door Schedule
No. Panel Height WidthHandleType
HardwareSet
PWDCompliant Closer
PanicBar
C/BJamb
TimberJamb Security Quantity Comments
D1 Half Glass : Hollow Core MC 2040 920 Lever Passage Yes Yes No Yes No Dead Lock,Crimsafe Type
Security Screen
1 E/E seals, LaminatedGrey Glass
D2 Standard : Hollow Core MC 2040 820 Standard Passage No Yes No Yes No Dead Lock,Indicator bolt
1 E/E seals, Door Grille
D3 Standard : Hollow Core MC 2040 820 Standard Passage No Yes No Yes No Dead Lock,Indicator bolt
2 E/E seals, Door Grille
D4 Standard : Hollow Core MC 2040 820 Lever Passage No Yes No Yes No Dead Lock,Indicator bolt
1 E/E seals, Door Grille
- Security FeaturesDescription Size Quantity
Crimsafe Type Security Screen 350 x 750. 1Crimsafe Type Security Screen 900 x 1200. 2Crimsafe Type Security Screen 900 x 1800. 3
Rev Description Date ByD Replaced EXT door hardwares w/ passage
set & dead lock, Replaced windowamplimesh screens w/ Crimsafe typescreens.
16.03.15 VT
E Added half glass c/w screen to D1,Relocated DSB, Added ceiling MTD drawwire conduit, Added Comms. cabinet.
06.05.15 VT
Assessor Name: Matthew Morelli
Certificate date: 10.10.18Dwelling address:
Ausnviro Pty LtdEnvironmental Rating Specialists
Office: 1300 NABERSMelbourne | Sydney | Brisbane | CanberraHead Office: Level 14, 470 Collins Street,
Melbourne
Lot 1 Honeycomb Drive,Eastern CreekCompliance Method: Deems to Satify (DTS)
THE ENDORSED PLANS HAVE BEEN PROVIDED BY THE CLIENT AND ASSESSED USING NCC PARTJ DTS PROVISIONS.
Accreditation number: VIC/BDAV/16/1737
ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
Greenacre, NSW 2190Hanson Construction
150108
12.0 x 6.0m Office Complex
- Drawing ListSheet
Number Sheet NameCurrentRevision
00 Title Page E01 Floor Plan E02 Elevations E06 Sales Schedules E
View indicative only
View indicative only
ENERGY REQUIREMENTS:
CEILING/ROOF - R2.8 ADDED INSULATION
EXTERNAL WALLS - R2.5 ADDED INSULATION
INTERNAL WALLS - R2.0 BETWEEN CONDITIONED & UNCONDITIONED AREAS
FLOOR - R1.0 ADDED INSULATION
WINDOWS GLAZING - SINGLE GLAZED GREYFRAMES - ALUMINIUM
GENERAL NOTES: ALL EXHAUST FANS TO BE SELF CLOSINGALL WINDOW FRAMES TO BE WEATHER STRIPPED.ALL GAPS AND CRACKS SEALED.ALL GLAZING TO REFER TO PART J REPORT FOR MINIMUM U & SHGC VALUES.HVAC SYSTEM TO COMPLY WITH ALL PARTS OF PART J5ARTIFICIAL LIGHTING TO COMPLY WITH ALL PARTS OF PART J6PLEASE NOTE R VALUES NOTED REPRESENT ADDED INSULATION AND NOT TOTAL R VALUE.
NOTE: These Energy Efficiency notes have been included in the Part J DTS Report and override ALL other energy notes.
Assessor Name: Matthew Morelli
Certificate date: 10.10.18Dwelling address:
Ausnviro Pty LtdEnvironmental Rating Specialists
Office: 1300 NABERSMelbourne | Sydney | Brisbane | CanberraHead Office: Level 14, 470 Collins Street,
Melbourne
Lot 1 Honeycomb Drive,Eastern CreekCompliance Method: Deems to Satify (DTS)
THE ENDORSED PLANS HAVE BEEN PROVIDED BY THE CLIENT AND ASSESSED USING NCC PARTJ DTS PROVISIONS.
Accreditation number: VIC/BDAV/16/1737
fw
222222
222222
22
2
2
2
2 2
2 2 2
2
2
2
PE
DSB
POE
02A
02C
02B
02D
A
1 2
B
C
12000
Verandah
1800
6000
Ver
anda
h
1800
96 4000 98 5628 98 2000 96
9658
2491
Floo
r-1
3000
Floo
r-2
3000
MEETING
x
D22040
920
x
W1600600x
W31808900
x
W31808900
x
W31808900
x
W31808900
x
W2908900
4
J15Jg
Je
WI
1
9128
2417
628
2496
23
UNISEXPWD WC
M1
x
D32040
920
RAMP (1:14) - By others
Covered verandah, landings,stairs/railings - TYP. - By others
OFFICE
KITCHEN
7 7
7 7
J2
Jf
PRINTER SPACE
Jc Jc
Jb Ja
1800 2028 1800
RECEPTION
8
NORTH(ASSUMED)
2° R
oof P
itch
C30030 Stiffened & Cambered.Paired Beams (Concealed) - TYP.
Partition walls- 1200H (TYP.)
COMMS. CABINET- BY OTHERS
MONITOR SPACE
6
STORAGE
96 4000 98 7726 96
J2
Jc Jc
Ram
p
1240
Stairs
900
Sta
irs
900
x
W31808900
M2M3
x
D12040
920
2126
9836
00THIS DRAWING REMAINS THE
PROPERTY OF ATCOSTRUCTURES PTY. LTD. IT MAY
NOT BE REPRODUCED ORCOPIED WHOLE OR IN PART
WITHOUT WRITTEN AUTHORITY
QUALITY CERTIFIED TO AS/NZSISO 9001:2008 BY SCI-QUAL
INTERNATIONAL REGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
Project No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3
ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS IMP. LEVEL
Greenacre, NSW 2190 1 : 100
13/0
5/20
15 1
2:45
:48
PM
EH:\02 Projects\2015\01-January\150108_Hanson Construction_SYD\02 Drawings\150108 RevE.rvt
Hanson Construction12.0 x 6.0m Office Complex
AAC
VT
150108 -01
12.01.15
Floor Plan Reg. B Cat. 2
5 2
- Fire fighting equipment supplied & installed by others.- Any 3D views are to be regarded as indicative only.- Draw Wires indicated for Data & Telecom - cable by others.- Comms. Cabinet - By others.- Skirtings around building are indicative only - By ATCO operations.- Covered verandah, landings, stairs/railings, ramp & tactile indicators shown
are indicative only - By others.- The Glazing Calculator for Energy Efficiency has been calculated upon the Northpoint indicated. Should the final postion vary, the Energy Efficiency may becompromised, and additional costs / redesign may be required for compliance.
Notes
1 : 100
Floor Plan1
1 Toilet Suite, Disabled c/w Grab Rails & Backrest2 Disabled Hand Basin - c/w Oversized Mirror Over3 Handbasin - Disabled Shelf4 S/S Insert Sink c/w Flickmixer & Drainer - 900x4505 Autoboiler - 2.5 litre - BIRKO c/w inbuilt timer6 Drinking Water Fountain Bubbler (BY OTHERS)7 Workstation - 1800x1800 (BY OTHERS)8 MeetingTable - 3000x1500 (BY OTHERS)fw Floor WasteJ1 Benchtop c/w splashback & end panels - Laminated -
32mm - Straight - 600 Deep - 2000 Long - 900 HighJ2 Benchtop c/w end panels - Laminated - 32mm - Straight
- 450 Deep - 1764 Long - 1200 HighJa Base Cabinet - 2 door, 1 shelf x 900wJb Base Cabinet - 4 Drawer x 400w c/w Cutlery InsertJc Base Cabinet - 2 door, 1 shelf x 850wJe Microwave Shelf - 600wJf Overhead Cupboard - 1 Door & 1 Shelf x 450 wideJg Overhead Cupboard - 2 Door & 1 Shelf x 900 wideWI Plumbing - Water Inlet
Item ListD1 6.38mm Grey Laminated Glass c/w
'Crimsafe Type' Security Screen.Shop Front Door
D2 2040 x 920 External Door - Standard : Hollow Core MCD3 2040 x 920 Internal Door - Standard : Hollow CoreW1 600 x 600 Sliding Glass Window - Obscure GlassW2 900 x 908 Sliding Glass Window - Grey GlassW3 900 x 1808 Sliding Glass Window - Grey GlassM1 Wall Mounted Exhaust FanM2 7.0kW R/C Split System Air ConditionerM3 5.0kW R/C Split System Air Conditioner
240V Smoke detector
Distribution Switchboard
36w Single fluorescent light
15amp Single GPO.10amp Double GPO10amp Single GPO
36w Single fluorescent light - IP65 rated
36w Double fluorescent light
10amp GPO - IPX5 rated
Comms. - Draw wire only
Light switchTwo-way light switch
'F' Type television outlet
Light switch - IPX5 rated
20amp Single GPO
Emergency exit light
36w Emergency back-up fluorescent light
POE - Point Of Entry
- Indicates floor mounting- Indicates ceiling mounting
DSB
IPX5
IPX5
WP
EXIT
Symbol Legend
2
Isolation Switch
External light18W Single Vandalite
Photo electric light switchSpot light
Oyster light
Oyster Light - 11W Round Fluro
PE
PLUMBING - Water Inlet PointPLUMBING - Waste Manifold Outlet Point
Emergency light - Spitfire 10W - battery backup
SALE STRUCTURAL NOTES for Reg. B Cat. 2 - Minimum Design Criteria
Dead and Live Windloads in accordance with the latest version of AS1170.2Wind Region: A or B - Terrain Category: 2Strength Design Wind Speed: Vu = 52m/sServiceability Wind Speed: Vs = 33.8m/sShielding Multiplier: 1.0 Topographic Multiplier: 1.0Earthquake Loads in accordance with the latest version of AS1170.4
WINDOW SPECIFICATIONULS (ULTIMATE) - 2.23kPASLS (SERVICEABILITY) - 0.91kPAWATER PENETRATION - 300PA
Rev Description Date ByD Replaced EXT door hardwares w/ passage
set & dead lock, Replaced windowamplimesh screens w/ Crimsafe typescreens.
16.03.15 VT
E Replaced D1 w/ Shop Front type c/wscreen, Relocated DSB & PE cell, Addedceiling MTD draw wire conduit,Reconfigured Comms. cabinet.
06.05.15 VT
Assessor Name: Matthew Morelli
Certificate date: 10.10.18Dwelling address:
Ausnviro Pty LtdEnvironmental Rating Specialists
Office: 1300 NABERSMelbourne | Sydney | Brisbane | CanberraHead Office: Level 14, 470 Collins Street,
Melbourne
Lot 1 Honeycomb Drive,Eastern CreekCompliance Method: Deems to Satify (DTS)
THE ENDORSED PLANS HAVE BEEN PROVIDED BY THE CLIENT AND ASSESSED USING NCC PARTJ DTS PROVISIONS.
Accreditation number: VIC/BDAV/16/1737
12
1 2
FFL
0
Ceiling
2710
GL
-530
A B C
App
rox.
Tra
nspo
rt H
eigh
t
3784
200
(App
rox.
Par
apet
Hei
ght)
FFL
0
Ceiling
2710
GL
-530
ABC
THIS DRAWING REMAINS THEPROPERTY OF ATCO
STRUCTURES PTY. LTD. IT MAYNOT BE REPRODUCED OR
COPIED WHOLE OR IN PARTWITHOUT WRITTEN AUTHORITY
QUALITY CERTIFIED TO AS/NZSISO 9001:2008 BY SCI-QUAL
INTERNATIONAL REGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
Project No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS IMP. LEVEL
Greenacre, NSW 2190 1 : 100
13/0
5/20
15 1
2:46
:01
PM
EH:\02 Projects\2015\01-January\150108_Hanson Construction_SYD\02 Drawings\150108 RevE.rvt
Hanson Construction12.0 x 6.0m Office Complex
AAC
VT
150108 -02
12.01.15
Elevations Reg. B Cat. 2
5 2
1 : 100
Elevation AA
1 : 100
Elevation BB
Maxirib External Cladding
2° Skillion Roof
Aluminium Framed WindowPermanently Vented Open (PVO)c/w Crimsafe Type Security Screen
Split System Air ConditionerCompressors
Commercial Shop Front External Doorc/w Crimsafe Type Security Screen
150PFC Skid Beams(In Skirtings)
1 : 100
Elevation DD
1 : 100
Elevation CC
Aluminium Framed Windowsc/w Crimsafe Type Security Screens
Scyon Matrix External Cladding
Metal Clad External Door
Rev Description Date ByD Replaced EXT door hardwares w/ passage
set & dead lock, Replaced windowamplimesh screens w/ Crimsafe typescreens.
16.03.15 VT
E Replaced D1 w/ Shop Front type c/wscreen, Relocated DSB & PE cell, Addedceiling MTD draw wire conduit,Reconfigured Comms. cabinet.
06.05.15 VT
Assessor Name: Matthew Morelli
Certificate date: 10.10.18Dwelling address:
Ausnviro Pty LtdEnvironmental Rating Specialists
Office: 1300 NABERSMelbourne | Sydney | Brisbane | CanberraHead Office: Level 14, 470 Collins Street,
Melbourne
Lot 1 Honeycomb Drive,Eastern CreekCompliance Method: Deems to Satify (DTS)
THE ENDORSED PLANS HAVE BEEN PROVIDED BY THE CLIENT AND ASSESSED USING NCC PARTJ DTS PROVISIONS.
Accreditation number: VIC/BDAV/16/1737
THIS DRAWING REMAINS THEPROPERTY OF ATCO
STRUCTURES PTY. LTD. IT MAYNOT BE REPRODUCED OR
COPIED WHOLE OR IN PARTWITHOUT WRITTEN AUTHORITY
QUALITY CERTIFIED TO AS/NZSISO 9001:2008 BY SCI-QUAL
INTERNATIONAL REGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
Project No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS IMP. LEVEL
Greenacre, NSW 2190
13/0
5/20
15 1
2:46
:05
PM
EH:\02 Projects\2015\01-January\150108_Hanson Construction_SYD\02 Drawings\150108 RevE.rvt
Hanson Construction12.0 x 6.0m Office Complex
AAC
VT
150108 -06
12.01.15
Sales Schedules Reg. B Cat. 2
5 2
Sales Window Schedule
No. Type Glazing Height WidthSill
HeightWindowMoulds Quantity Comments
W1 PVO Obscure Glass 600 600 1700 Timber 1W2 Sliding XO Grey Glass 900 908 1200 Timber 1W3 Sliding XO Grey Glass 900 1808 1200 Timber 5
Sales Roof Structure ScheduleRoof Structure Comments
2° Skillion Roof (Complexing On Site - By ATCO operations)600mm Ceiling Joist CentresCeiling Joist - SLC7512Insulation - R2.3 Foil Backed Blanket- 95mmLining - Internal - 10mm Plasterboard Painted FinishPurlins - LC7512Roof - 0.42mm BMT Superdek Roofing
- Wall ScheduleWall Structure Comments
External Wall - Plasterboard Internal600mm Stud CentresCladding - 8mm Matrix Cladding As IndicatedCladding - External - Maxirib - Horizontal As IndicatedFraming - LC7810Insulation - R3.1 Batts - 75mmInsulation - Sisalation Wall WrapLining - Internal - 10mm Plasterboard Painted FinishThermal Break between Framing and CladdingInternal Wall - Plasterboard600mm Stud CentresFraming - LC7810Lining - Internal - 10mm Plasterboard Painted Finish
* Plumbing FixturesNo. Description Quantity Comments
1 Toilet Suite, Disabled c/w Grab Rails & Backrest 12 Disabled Hand Basin - c/w Oversized Mirror Over 1 Cold Only3 Handbasin - Disabled Shelf 14 S/S Insert Sink c/w Flickmixer & Drainer - 900x450 1 Cold Only5 Autoboiler - 2.5 litre - BIRKO c/w inbuilt timer 16 Drinking Water Fountain Bubbler (BY OTHERS) 1fw Floor Waste 1WI Plumbing - Water Inlet 1
Lighting Fixtures Quantity1x36W Fluro & Diffuser 12x36W Fluro & Electronic Ballast Diffuser 9Photo Electric Cell 1Single Vandalite - Wall Mounted 2Switch - Std 3
- Electrical FixturesDescription Quantity
1x10amp GPO 21x15amp GPO - Autoboil 12x10amp GPO 242x10amp GPO - Floor Mounted 1Comms. Cabinet - 600W x 550D x 635H (BY OTHERS) 1Draw Wire 18Draw Wire (With Conduit - Ceiling To Floor) - CeilingMounted.
1
Draw Wire - Floor Mounted 1Isolation Switch - AC 2Switchboard 1
- FurnitureNo. Description Quantity Comments
7 Workstation - 1800x1800 (BY OTHERS) 48 MeetingTable - 3000x1500 (BY OTHERS) 1
- CupboardsNo. Description Quantity CommentsJ1 Benchtop c/w splashback & end panels -
Laminated - 32mm - Straight - 600 Deep - 2000Long - 900 High
1
J2 Benchtop c/w end panels - Laminated - 32mm -Straight - 450 Deep - 1764 Long - 1200 High
2
Ja Base Cabinet - 2 door, 1 shelf x 900w 1Jb Base Cabinet - 4 Drawer x 400w c/w Cutlery Insert 1Jc Base Cabinet - 2 door, 1 shelf x 850w 4Je Microwave Shelf - 600w 1Jf Overhead Cupboard - 1 Door & 1 Shelf x 450 wide 1Jg Overhead Cupboard - 2 Door & 1 Shelf x 900 wide 1
Sales Mechanical EquipmentNo. Supplier Description QuantityM1 AIRFLOW Wall Mounted Exhaust Fan 1M2 TCL 7.0kW R/C Split System Air Conditioner 1M3 TCL 5.0kW R/C Split System Air Conditioner 1
- Floor Structure ScheduleFloor Structure Comments
Floor600mm Floor Joist CentresCovering - 2.0mm Non-Slip Vinyl - Unisex PWDWC Area Only
150mm Coved
Covering - 2.0mm VinylFloor Joists - LC7512Flooring - 17mm F11 T&G PlywoodInsulation - Under Floor - R2.1 Heavy Duty FoilFaced Batts
Wall Height2710
- Security FeaturesDescription Size Quantity
Crimsafe Type Security Screen 600 x 600. 1Crimsafe Type Security Screen 900 x 900. 1Crimsafe Type Security Screen 900 x 1800. 5
Manufacturing Structural Members
DescriptionMember
SizeBack to
BackSkid Beams c/w Retractable Lifters 150PFC 2000Paired Beams (Concealed) - TYP. C30030
Stiffened &Cambered.
Sales Door Schedule
No. Panel Height WidthHandleType
HardwareSet
PWDCompliant Closer
PanicBar
C/BJamb
TimberJamb Security Quantity Comments
D1 Shop Front Door 2040 920 Push/PullHandle
Entrance Yes Yes Crimsafe TypeSecurity Screen
1 E/E seals, LaminatedGrey Glass
D2 Standard : Hollow Core MC 2040 920 Lever Passage Yes Yes No No Yes Dead Lock,Indicator bolt
1 E/E & weather seals
D3 Standard : Hollow Core 2040 920 Lever Passage Yes No No No Yes 1
Rev Description Date ByD Replaced EXT door hardwares w/ passage
set & dead lock, Replaced windowamplimesh screens w/ Crimsafe typescreens.
16.03.15 VT
E Replaced D1 w/ Shop Front type c/wscreen, Relocated DSB & PE cell, Addedceiling MTD draw wire conduit,Reconfigured Comms. cabinet.
06.05.15 VT
Assessor Name: Matthew Morelli
Certificate date: 10.10.18Dwelling address:
Ausnviro Pty LtdEnvironmental Rating Specialists
Office: 1300 NABERSMelbourne | Sydney | Brisbane | CanberraHead Office: Level 14, 470 Collins Street,
Melbourne
Lot 1 Honeycomb Drive,Eastern CreekCompliance Method: Deems to Satify (DTS)
THE ENDORSED PLANS HAVE BEEN PROVIDED BY THE CLIENT AND ASSESSED USING NCC PARTJ DTS PROVISIONS.
Accreditation number: VIC/BDAV/16/1737