Page 1: Hansen House (Passive house Miguel Salgado)

PASSIVE HOUSE

Group: 19

Miguel SalgadoPedro RicoAdam Marko

Page 2: Hansen House (Passive house Miguel Salgado)

1. INTRODUCTION LOCATION

Galgehøj, 8700 Horsens Plot 33

Page 3: Hansen House (Passive house Miguel Salgado)

2. DESIGN A/V FACTOR

NUMBER OF FLOORS 2

A (GROSS FLOOR AREA) 154m2

A (BUILDING ENVELOPE) 420m2

V (GROSS ENVELOPE) 539m3

A/V 0,78m2/m3

Page 4: Hansen House (Passive house Miguel Salgado)

2. DESIGN AREAS

Ground floor

Page 5: Hansen House (Passive house Miguel Salgado)

2. DESIGN AREAS

1st floor

Page 6: Hansen House (Passive house Miguel Salgado)

2. DESIGN DIMENSIONS

Ground floor

Page 7: Hansen House (Passive house Miguel Salgado)

2. DESIGN DIMENSIONS

1st floor

Page 8: Hansen House (Passive house Miguel Salgado)

2. DESIGN U-VALUES

Assembly No. Building assembly description Interior insulation?

1 External Wall

Heat transfer resistance [m²K/W] interior Rsi : 0,13exterior Rse : 0,04

Area section 1l [W/(mK)] Area section 2 (optional)

l [W/(mK)] Area section 3 (optional)l [W/(mK)] Thickness [mm]

1. Brick 0,600 108

2. Insulation 0,032 350

3. Finish layer 0,250 10

4.

5.

6.

7.

8.Percentage of Sec. 2 Percentage of Sec. 3 Total

46,8 cm

U-Value: 0,088 W/(m²K)

Page 9: Hansen House (Passive house Miguel Salgado)

2. DESIGN U-VALUES

Assembly No. Building assembly description Interior insulation?

2 Roof

Heat transfer resistance [m²K/W] interior Rsi : 0,26

exterior Rse : 0,04

Area section 1 l [W/(mK)] Area section 2 (optional) l [W/(mK)] Area section 3 (optional) l [W/(mK)] Thickness [mm]

1. Tile 1,000 20

2. Mortar 0,100 100

3. Insulation 0,034 400

4. Mortar 0,100 50

5. Concrete 1,600 200

6.

7.

8.Percentage of Sec. 2 Percentage of Sec. 3 Total

77,0 cm

U-Value: 0,073 W/(m²K)

Page 10: Hansen House (Passive house Miguel Salgado)

2. DESIGN U-VALUES

Assembly No. Building assembly description Interior insulation?

3 Ground Floor supporter floor

Heat transfer resistance [m²K/W] interior Rsi : 0,17

exterior Rse: 0,00

Area section 1l [W/(mK)] Area section 2 (optional)

l [W/(mK)] Area section 3 (optional)l [W/(mK)] Thickness [mm]

1. Parquet 0,200 20

2. concrete 1,600 100

3. Hard insulation 0,037 350

4. Light clincker 0,085 250

5. Light clincker 0,102 75

6.

7.

8.Percentage of Sec. 2 Percentage of Sec. 3 Total

79,5 cm

U-Value: 0,074 W/(m²K)

Page 11: Hansen House (Passive house Miguel Salgado)

2. DESIGN ORIENTATION AND WINDOWS

WINDOWS

NORTH 9,5%

EAST 22,1%

SOUTH 44,9%

WEST 23,5%

Page 12: Hansen House (Passive house Miguel Salgado)

2. DESIGN ORIENTATION AND WINDOWS

Glazing.

Frame

Page 13: Hansen House (Passive house Miguel Salgado)

2. DESIGN SHADINGS

Page 14: Hansen House (Passive house Miguel Salgado)

2. DESIGN ELEVATIONS (SOUTH)

Page 15: Hansen House (Passive house Miguel Salgado)

2. DESIGN ELEVATIONS (EAST)

Page 16: Hansen House (Passive house Miguel Salgado)

2. DESIGN ELEVATIONS (WEST)

Page 17: Hansen House (Passive house Miguel Salgado)

2. DESIGN ELEVATIONS (NORTH)

Page 18: Hansen House (Passive house Miguel Salgado)

2. DESIGN SECTIONS (A-A’)

A’

A

B’B

Page 19: Hansen House (Passive house Miguel Salgado)

2. DESIGN SECTIONS (B-B’)

A’

A

B’B

Page 20: Hansen House (Passive house Miguel Salgado)

2. DESIGN DETAILS

Wall-Window

Page 21: Hansen House (Passive house Miguel Salgado)

2. DESIGN DETAILS

Roof-Wall

Air thingt layer

Page 22: Hansen House (Passive house Miguel Salgado)

3. INSTALATIONS VENTILATION

Passive House Standard

Supply air:30m3/h/person * 4 person = 120m3/h

Extract air:

1 Kitchen: 60 m3/h3 Bathrooms: 40 m3/h * 3 = 120 m3/h2 Storage room: 40 m3/h

Total= 220 m3/h

Minimun ari change of 0,3/h:

0,3/h*144 m2*2,5= 108 m3/h

Page 23: Hansen House (Passive house Miguel Salgado)

3. INSTALATIONS VENTILATION

INNOAIR 300 DC (max. 300 m³/h bei 100 Pa.)

Page 24: Hansen House (Passive house Miguel Salgado)

3. INSTALATIONS VENTILATION (SUPPLY)

Room No qbasic

(l/s)qbasic

(m3/s)Ʃq dimensioning

(m3/s)Type (M, B, C)

Velocity(m/s)

Duct dimension (calculated) (m)

Final duct dimension (mm)

Living room

12,5 0,0125 0,0125 C 2,5 75 75

Dinnigroom

12,5 0,0125 0,0125 C 2,5 75 75

Branch1

25 0,0250 0,0250 B 3,5 90 90

Room 1 11,2 0,0112 0,0112 C 2,5 75 75

Room2

11,2 0,0112 0,0112 C 2,5 75 75

Branch2

22,4 0,024 0,024 B 3,5 100 100

Room3

17 0,017 0,017 C 2,5 100 100

Branch3

39,4 0,0394 0,0394 B 3,5 125 125

Main 64,4 0,0644 0,0644 M 4 150 150

Page 25: Hansen House (Passive house Miguel Salgado)

3. INSTALATIONS VENTILATION (EXTRACTION)

Room No qbasic

(l/s)qbasic

(m3/s)Ʃq dimensioning

(m3/s)Type (M, B, C)

Velocity(m/s)

Duct dimension (calculated) (m)

Final duct dimension (mm)

Kitchen 20 0,020 0,020 C 2,5 90 90

Bathroom1

15 0,015 0,015 C 2,5 75 75

Branch1

35 0,0350 0,0350 B 3,5 110 110

Storage1

10 0,01 0,01 C 2,5 75 75

Brach2

45 0,045 0,045 B 3,5 125 125

Bathroom2

15 0,015 0,015 C 2,5 75 75

Storage2

10 0,01 0,01 C 2,5 75 75

Bathroom3

15 0,015 0,015 C 2,5 75 75

Brach3

40 0,04 0,04 B 3,5 125 125

Main 85 0,085 0,085 M 4 175 175

Page 26: Hansen House (Passive house Miguel Salgado)

3. INSTALATIONS VENTILATION (PLANS)

Ground floor

Suppy

Extract

Page 27: Hansen House (Passive house Miguel Salgado)

3. INSTALATIONS VENTILATION (PLANS)

1st floor

Suppy

Extract

Page 28: Hansen House (Passive house Miguel Salgado)

3. INSTALATIONS VENTILATION

Suppy

Extract

Page 29: Hansen House (Passive house Miguel Salgado)

3. INSTALATIONS DOMESTIC HOT WATER

Ground floor

Page 30: Hansen House (Passive house Miguel Salgado)

3. INSTALATIONS DOMESTIC HOT WATER

1st floor

Page 31: Hansen House (Passive house Miguel Salgado)

3. INSTALATIONS DOMESTIC HOT WATER

Page 32: Hansen House (Passive house Miguel Salgado)

4. CONCLUSIONS VERIFICATION

Page 33: Hansen House (Passive house Miguel Salgado)

THATS ALL!!THANKS!!