hal s3201 - brochure 2011_noprices (1)

6
® Gaumard Simulators for Health Care Education HAL ® S3201 ... a proven tetherless simulator • Simulation Made Easy TM • Fully responsive in transit • Wireless streaming audio • Automatic or instructor control

Upload: omar-garcia-munoz

Post on 10-Mar-2015

99 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: HAL S3201 - Brochure 2011_noprices (1)

®GaumardSimulators for Health Care Education

HAL® S3201

. . . a proven tether less s imulator• SimulationMadeEasyTM

• Fullyresponsiveintransit

•Wirelessstreamingaudio

• Automaticorinstructorcontrol

Page 2: HAL S3201 - Brochure 2011_noprices (1)

HAL® S3201HAL S3201combines thebestofsimulationtechnologiesinanaffordablepackage.

EasytoUseOur intuitiveandpowerful3Duserinterfacedefines...SimulationMadeEasyTM

ReliableProven HALtechnologysoruggeditwasawardedanairworthinesscertificatebytheUSArmy

UseRealDevicesConnectdirectlytoarealventilator.Useareal12leadECGmonitor,realOsatmonitors,BPcuffs,defibrillatorsorexternalcardiacpacemakers.

AffordableGaumarddedicatesitstalentstoprovidingsimulatorsataffordableprices.Thisprincipleremainsastruetodayasitwasover50yearsago.

TetherlessTetherlesstechnology,pioneeredbyGaumardin2004,allowsthecommunications,compressor,andpowersupplytobeinsidethesimulator,eliminatingexternaltubes,wiresandcompressors.

Advanced“Beyondcomplexityliessimplicity”...HALtechnologyissoadvanceditisactuallyeasytouse

Pro+|Recordinganddebriefingsystem

Pro+issuppliedwithtwowirelessandonewiredcamera.Capturemultiplevideo(withwiredorwirelesscameras),audio,andpatientmonitors,aswellasthesimulatorlogfile.ControlbothsimulationandrecordingsimultaneouslyusingonePC.

Page 3: HAL S3201 - Brochure 2011_noprices (1)

Dynamicairwayandlungcompliance

Changelungcompliance/airwayresistanceduringscenarioandseeresultsonarealventilator.HALholdsPEEP,triggerstheventilator,andexhalesrealandmeasurableCO2.Useourpre-programmedpathologiesorcreateyourown.

12leadECGwithintegratedMImodel

DisplayandinterpretHAL’s12leadECGusingyourreal12leadmonitor.ChoosefromthethousandsofcardiacrhythmsinourECGlibraryorcreateyourownwithourrhythmeditor.UseintegratedMImoduletospecifyocclusions,ischemiaornecrosis.

Drugrecognition

Identifiesdrugtypeandvolumeinjectedintoveinsofrighthandandforearm.Useourformularyoryours.Effectisdeterminedbyphysiologicmodel,updatingthesimulatedvitalsignsmonitor.

Page 4: HAL S3201 - Brochure 2011_noprices (1)

AutomaticMode

Respondstocaregiverorinstructoractions;topharmacologicintervention,toinjury;ortocardiacandrespiratoryevents

ReactiveEyes

HALhasblinkingeyeswithphotosensitivepupils.Dilation,reactivity,andblinkratecanbecontrolledautomaticallyorbytheinstructor.

TabletPCHALincludesa12inchtouchscreentabletPCwithstyluscontrol,“bump”caseandscenarios

TheMonitors

• Includes17inchtouchscreenvirtualmonitororupgradetoa12inchtabletvirtualmonitor

• Customizeeachtraceindependently;userscansetalarms,andtimescales.

• Displayupto12numericvaluesincludingHR,ABP,CVP,PAWP,NIRP,CCO,SpO2,SvO2,RR,EtCO2,temperature,andtime

• Selectupto12dynamicwaveformsincludingECGLeadI,II,III,aVR,aVL,aVF,V1,V2,V3,V4,V5,V6,AVP,CVP,PAWP,pulse,CCO,SvO2,respiration,capnography.

• Shareimagessuchasx-rays,CTscans,labresults,orevenmultimediapresentationsasthescenarioprogresses

WirelessStreamingAudio

BethevoiceofHALandhearcaregiverresponses.Createandstorevocalresponsesorselectfromapre-recordedvocalmenu.

Page 5: HAL S3201 - Brochure 2011_noprices (1)

MeasureOSATusingrealoximeter

MeasureBloodPressureusingrealcuff

OralandNasalIntubationReactiveEyes

CentralCyanosis

Defibrillate,cardiovertandpaceusingrealdevices

12LeadECGDynamicAirwayandLungCompliance

AutomaticChestRise BilateralIVarms

TheSoftware|GIGATM

Ourintuitiveandpowerfulsoftwareofferseaseofuseandtheflexibilityrequiredbythemostdemandingusers

GIGA Features

•Basicviewprovideswindowsforthe3Dmodelofthesimulator,acompletelyconfigurablevitalsignsmonitorandanactivitieslog.• 3Dimagecanberotatedorenlarged;theskinremovedandphysiologicparametersaccessedtochangeanyelementsofapowerfulphysiologicengine.• Physiologicparametergroupsincludeairway,breathing,cardiac,cephalicandcirculation.Moveeachaboutthestatuspanel.• Expandwindowstoincludestatus,palettes,scenario,branchingscenario,actions,log,monitors,CPRrecorder,speech,medication,andquickmeds.• Specifyonlyfrequentlyusedparametersorbeasdetailedasyouwish.

Realisticsurgicaltrachea

Page 6: HAL S3201 - Brochure 2011_noprices (1)

General•Availableinethnicskintones• Tetherlessandfullyresponsiveevenwhilebeingtransported•Poweredfromaninternalrechargeablebatteryorwalloutlet•Batteryoperatesthesimulatorupto5hours• SimulatorreceivescommandsfromawirelesstabletPCandoperatesatdistancesupto300meters• Simulatormaybeusedoutdoorsorindoors;becoveredwithablanketorplacedinaNATOlitter• Simulatorcanoperateautomaticallyusinga“physiologic”modelorbytheinstructor•Optionalprogrammablebleedingarmsandlegs• Instructionmanualwithbothbasicandadvancedinteractivescenarios•Usepreprogrammedscenarios,modifythemorcreateyourownquicklyandeasily• Installationandtrainingworldwide•SimulationMadeEasyTM

Airway• Programmableairway:tongueedema,laryngospasm,andpharyngealswelling•Multipleupperairwaysoundssynchronizedwithbreathing•Nasalororalintubation•Rightmainstemintubation•Sensorsdetectdepthofintubation•Airwaymaybeobstructed•Blockrightlung,leftlung,orbothlungs•Headtilt/chinlift•Jawthrust•Simulatedsuctioningtechniquescanbepracticed•Bag-Valve-MaskVentilation•Placementofconventionalairwayadjuncts•EndotrachealintubationusingconventionalETTs•Retrogradeintubation•Sellickmaneuverbringsvocalcordsintoview•Realisticsurgicaltracheaallowstracheostomyorneedlecricothyrotomy•Tracheostomycareandsuctioning

Breathing•Controlrateanddepthofrespirationandobservechestrise•Automaticchestriseissynchronizedwithrespiratorypatterns•Selectindependentlungsounds:upperrightfrontandback;upperleftfrontanback;lowerrightfrontandback;lowerleftfrontandback•Chestriseandlungsoundsaresynchronizedwithselectablebreathingpatterns•AccommodatesassistedventilationincludingBVMandmechanicalsupport•Ventilationsaremeasuredandlogged•GastricdistensionwithexcessiveBVMventilation•Detectionandloggingofventilationsandcompressions•Simulatedspontaneousbreathing•CO2onexhalation(4levels)usingreplaceablecartridgemountedinsidethesimulator•Variablerespiratoryratesandinspiratory/expiratoryratios•Attachtorealmechanicalventilators•Bilateralchestriseandfall•Unilateralchestrisesimulatespneumothoraces•Normalandabnormalbreathsounds•Anteriorandposteriorauscultationsites•Bilateralneedledecompressionatsecondintercostal•DynamicAirwayandLungcompliance/resistance- Tenlevelsofstaticcompliance, 15-50ml/cmH2O- Tenlevelsofairwayresistance- Useinconventionalventilationmodes- HoldsPEEPfrom5to20cmH2O- ExhalesrealandmeasurableCO2- Varylungmechanicsthroughoutscenario- Receiverealtimefeedbackfromrealmechanicalventilator

- Capableofassistingtheventilatoratvariablerespiratoryrate

- Complianceandresistancecanbevariedwhileconnectedtotheventilator

Cardiac •ECGsaregeneratedinrealtimewithphysiologicvariationsneverrepeatingtextbookpatterns•HeartsoundsmaybeauscultatedandaresynchronizedwithECG•ECGrhythmsshownforeachofthe12leads•Viewdynamicratherthanstatic12leadrhythms• 12LeadECGwithintegratedMImodel- Useyourreal12leadmonitor- ExtensiveHALECGlibrary- Specifyother12leadECGsusingoureditor- UseintegratedMImoduletospecifyocclusions,ischemiaornecrosis

Circulation •Measurebloodpressurebypalpationorauscultation•UserealBPcuffratherthana“virtual”cufftomeasurebloodpressure•Korotkoffsoundsaudiblebetweensystolicanddiastolicpressures•Oxygensaturationdetectedusingrealmonitorsratherthana“virtual”value•PulsesitessynchronizedwithBPandheartrate•BilateralIVarmswithfill/drainsites•Realisticflashback•SubQandIMinjectionsites•Intraosseousaccessattibia•Chestcompressionsaremeasuredandlogged•ChestcompressionsgeneratepalpablebloodpressurewaveformandECGartifacts•ECGmonitoringusingrealdevices•Defibrillate,cardiovertandpaceusingrealdevices•Multipleheartsounds,ratesandintensities•ECGrhythmsaregeneratedinrealtime•HeartsoundssynchronizedwithECG•Dynamicratherthanstatic12leadECGdisplay•Pacingmaybepracticedanteriorally•Bilateralcarotid,radial,brachial,femoral,poplitealandpedalpulsessynchronizedwithECG•Pulsesvarywithbloodpressure,arecontinuousandsynchronizedwiththeECGevenduringapacedrhythm

Instructor or Automatic Mode•Intuitiveinterfaceandautomaticitymakessimulationeasy•Vitalsignsaregeneratedinrealtime•Druglibrarywithmedications•Useofmedicationschangeconditionsinrealtimemimickingrealclinicalsituations

Drug Recognition System•Identifiesdrugtypeandvolumeinjectedintoveinsoftherighthandandforearm•Suppliedwith100syringeshavingwirelesstags•Usedrugsfromlibraryorchoosetomodelotherdrugsusingsoftwaretemplate•Physiologicmodelsupdatesimulatedvitalsignsmonitors•Additionalpacksof20syringeswithtagsavailable•22gaugeneedlerecommended;largerneedleswilldecreasevenouslife•Suppliedwitheasilyreplaceableveins

Neural Responses•Eyesarecontrolledautomaticallybyphysiologicmodelordirectlybytheinstructor•Eyesopenandclose•Selectblinkrate•Selectpupillaryresponsetolight

Speech•Wirelessstreamingaudio•Prerecordedsounds•Createandstorevocalresponsesinanylanguage•Instructorcansimulatepatient’svoiceandlistentocaregiversconversationwirelessly•Bethevoiceofthesimulatorandhearresponsesatdistancesupto50meters

Vital Signs Monitor•ControlledviawirelesstabletPC•Simulatedvitalsigns•Useselectedconfigurationorcreateyourownconfigurationtomimictherealmonitorsusedinyourfacility•Customizealarms•Easytooperateandcontrol•Reflectsimulator’sconditionduringthescenario•Shareimagessuchasultrasounds,CTscans,labresults•Touchscreencontrol•Monitorcanbeconfiguredbytheinstructortosuitthescenario•Displayupto12numericparameters•Selectupto12dynamicwaveforms

Articulation and Movement•Seizure/convulsions•Realisticrotationoftheshoulderandhipjoints•Legsbendattheknees•Supineorsemi-recumbentpositions

Other•Centralcyanosis•FillbladderandperformFoleycatheterization•Interchangeablegenitalia•Insertfeedingtubes•Auscultatebowelsounds•Remainsfullyfunctionalevenwhileintransit• Softcarryingcase

User Interface •Sensorstrackstudentactions•Changesinconditionandcareprovidedaretimestampedandlogged•Viewtheactionsofupto6careprovidersusingaresponsivemenuorwritenarrative•Generateandsharediagnosticlabresults•Linkswithoptionalrecordinganddebriefingsystemintegratingtheeventlogwithcamerasandpatientmonitor•SuppliedwithwirelesstabletPC•Interactive“Physiologic”modeling•26preprogrammedscenarioswhichcanbemodifiedbytheinstructorevenduringthescenario•Createyourownscenarios-add/edit•Changesimulator’sconditionduringthescenario•Optionalintegratedthreecamerarecordinganddebriefingsystemavailable- ControlbothsimulationandrecordingsimultaneouslyusingonePC

-Capturemultiplevideo,audio,andpatientmonitors,aswellassimulatorlogfilefordebriefing

S3201 |HAL

Patented;otherpatentspending

Optional Add-Ons1

Pro+ recording and debriefing system 2

S3201.211 |

Traumatic leg amputation

S3201.004 |

Traumatic arm amputation

S3201.005 |

Upgrade to 12 inch tablet virtual monitor

S3201.003 |

Toll Free: USA 800.882.6655 - Worldwide: 305.971.3790 - Fax: 305.667.6085Email: [email protected] - www.gaumard.com - Gaumard Scientific, 2011

HAL®S3201...apartofGaumard’sgrowingfamilyoftetherlesssimulators

1 Price applicable with initial purchase. Contact us for upgrade pricing2 Pro+ recording and debriefing system includes two wireless cameras, one wired camera,

and access to the Pro+ software. Pro+ works in the same tablet used to control simulator

MADE IN AMERICA