Elements of engineering

Guided by: Prepared by:Hitesh S. Patel Shukla harshita

131120131049 Branch- computer & sci engineering

Electrical engineering.

Page 2: Guided by: Prepared by: Hitesh S. Patel Shukla harshita 131120131049 Branch- computer & sci engineering

Types of wire and cable

Page 3: Guided by: Prepared by: Hitesh S. Patel Shukla harshita 131120131049 Branch- computer & sci engineering

Types of wires• For domestic wiring,the most extensively used conductor matirial is aluminium and copper which are properly insulated.• wires used for ordinary purpose are of single strand.• but for the power circuit such as mixer point,refrigerator point,iorn point,etc.where current may be more than 5Amp in such cases multistrand wires are used.• following are the different types of wires used in electrical installation work:

1. V.I.R. wires 4.lead alloy sheathed wires2. C.T.S or T.R.S. wires 5. weather proof wires3. P.V.S. wires 6. flexible wires

Page 4: Guided by: Prepared by: Hitesh S. Patel Shukla harshita 131120131049 Branch- computer & sci engineering

V.I.R(vulcanised indian ruubber)wires•Tinning of conductor prevents the sticking of rubber to yhe conductor.• thickn A V.I.R wire mainly consist of a tinned conductor having rubber coating.•ess of rubber mainly depends on the opreting voltage to whichwire is designed.• a cotton bradding is done over the rubber insulation to protect the conductor against the moisture.

Page 5: Guided by: Prepared by: Hitesh S. Patel Shukla harshita 131120131049 Branch- computer & sci engineering

• now a days these wires are not used since a better quality wires are available at a cheaper rate.• finally the wire is finished with wax for cleanliness.

Page 6: Guided by: Prepared by: Hitesh S. Patel Shukla harshita 131120131049 Branch- computer & sci engineering

C.T.S(cab type sheated)wires

• This type of wire is modification of V.I.R wire. It consist of the ordinary rubber coated conductors with an additional seath of tough rubber.

• this layer provides better protection againts moisture and wear and tear.also it provides an extra insulation.

• these wires are genrally available in singal conductor , two conductors or three conductors.

Page 7: Guided by: Prepared by: Hitesh S. Patel Shukla harshita 131120131049 Branch- computer & sci engineering

P.V.S.(poly vinyl cloride)wires

• this is the most commonly used wire for wiring purpose.• conductor is insulated by P.V.S.• P.V.S. has following properties.1. Moisture proof 2. tough3. Durable 4.

chemically inert

Page 8: Guided by: Prepared by: Hitesh S. Patel Shukla harshita 131120131049 Branch- computer & sci engineering

Lead alloy sheathed wires

• the ordinary wires can be used only at dry places but for damp places these wires are coverd with continuous lead sheaths.• the layer of lead covring is very thin like 0.12 cm thick.• these wires provides little mechanical protection to the wires.

Page 9: Guided by: Prepared by: Hitesh S. Patel Shukla harshita 131120131049 Branch- computer & sci engineering

Weather proof wires• these types of wires are used outdoor providing a service connection from overhead line to building etc.• in this type of wire the conductor is not tinned and the conductor is coverd with three braids of fibrous yarn and saturated with water proof compound.

Page 10: Guided by: Prepared by: Hitesh S. Patel Shukla harshita 131120131049 Branch- computer & sci engineering

Flexible wires

• these wires consist of number of strands instead of a single conductor.• the conductor is insulated with P.V.C.matirial.• these wires are very useful for household portable appliances where flexibility of wire is more important.

Page 11: Guided by: Prepared by: Hitesh S. Patel Shukla harshita 131120131049 Branch- computer & sci engineering

CablesUnderground cables are genrally classified into two ways:

1. according to the voltage level2. according to the insulating matirial

used. Generally first method of classification is

prefferred and it is further classiffied as:3. Low tention cables = upto 1000v4. high tention cables = upto 11000v5. super tention cables = from 22kv to 33

kv6. extra high tention cables = from 33 to

66 kv7. extra super voltage cables = beyound

132 kv.

Page 12: Guided by: Prepared by: Hitesh S. Patel Shukla harshita 131120131049 Branch- computer & sci engineering

Low tention cables

• these cables are genrally used for voltages up to 1000 v. these cables can be used for 6600 v. also as the electrostatic stress developed in the cables are very small.• fig shows the cross section of a single core low tention cable.• it consist of one circular core of tinned strand copper conductors insulated by layers of impregnated paper.

Page 13: Guided by: Prepared by: Hitesh S. Patel Shukla harshita 131120131049 Branch- computer & sci engineering

High tention cables

• fig shows the cross sectional view of 3 cope belted type high tention cable.• these cables are used upto 11000 v• it consist of three cores of strands copper.• these three cores are insulated from each other by layers of impregnated paper.

Page 14: Guided by: Prepared by: Hitesh S. Patel Shukla harshita 131120131049 Branch- computer & sci engineering

• three insulated cores are bunched together and wrapped with impregnated paper.• to have a circular cross sectional area the gaps between the insulated core are filled with fibrous insulating material.• lead sheath is wrapped around the paper belt which provids the protection against moisture.• cable is provided with armouring to protect the cable against the mechanical injury.• finally serving is provided over the armouring.

Page 15: Guided by: Prepared by: Hitesh S. Patel Shukla harshita 131120131049 Branch- computer & sci engineering

Super tention cable

•For voltage above 11000 v special construction of cable is required.• screened cables are used upto 33000 v in which leakage currents are diverted to earth through metalic sheath.

Page 16: Guided by: Prepared by: Hitesh S. Patel Shukla harshita 131120131049 Branch- computer & sci engineering