guide for fitting handle-less rail - myba — dashboard · 2020. 2. 10. · guide for fitting...
TRANSCRIPT
-
REF: 230518
Base Units - Guide for Doors & Drawer Sizes: Standard layout shown. Suitable for Made-to-Measure.
Hinge Drillings – Door Drillings for Standard Base Unit with 100mm Drillings (Includes Clic Box)
• Door Top Hinge = 71mm
• Door Bottom Hinge = 98mm
Base Units – Standard Door Installation:
Cut unit top back 95mm from front edge to allow space for
Universal Connector
Cut units for Single Rail Profile as
shown.
Guide for Fitting Handle-less Rail
Step 2
Square or Radius
Cut. R.6mm
257
257
Step 1
Note: All Layouts Shown Use Standard Clic Box Drilling Patterns
-
REF: 230518
Drill units for Profile Connectors using 2mm drill bit.
*Note: Careful consideration should be given to the planning and installation of built-in under appliances.
It is advisable to check appliance manufacturers’ technical specifications and set the height of the base
units accordingly.
Some built-in under appliances are not suitable for handle-less rail installations.
Base Units – drawer Installation:
Step 3
Step 4 Step 5
Cut Single Rail Profile
to size and Snap-On to
Profile Connectors.
Step 6
If External Plant-On Gables are
not being used – Use Single Rail
External Caps.
Secure Profile Connectors
to pre-drilled holes using
30mm screws.
Step 1
Step 2
Cut units for Single &
Double Rail Profiles
as shown.
Drill units for Profile
Connectors using
2mm drill bit.
Square or Radius
Cut. R. 6mm
Square or Radius
Cut. R. 6mm
Note: All Layouts Shown Use Standard Clic Box Drilling Patterns
-
REF: 230518
Base Corner Units Installation:
Step 3
Step 4 Step 5
Secure Profile
Connectors to pre-
drilled holes using
30mm screws.
Cut Single & Double Rail Profiles to
size and Snap-On to the Profile
Connectors.
If External Plant-On Gables are not
being used – Use Single & Double Rail
External Caps.
Step 1 Step 2
Cut & Drill gables
of Corner Unit
the same as a
Standard Door
Installation.
Mitre cut Rail
Profiles at
corner and use
the Single Rail
90° Internal
Corner
Connector to
fix together.
Note: All Layouts Shown Use Standard Clic Box Drilling Patterns
-
REF: 230518
Island Installation:
Tall/Vertical Unit Installation:
The Single & Double Rail Profiles may be
returned at the ends of a base unit or on an
Island Installation.
For Returns – Mitre cut Rail Profiles at the
end of the unit gables and use 90° External
Corner Connector to fix together. C or G
Gables are recommended for this kind of
installation pending on desired finish.
Step 1
Gables
Tall/Vertical Plan View
Back
17m
m
Cut front of carcass
gables back 17mm.
Step 2 Drill units for Profile Connectors.
Note: All Layouts Shown Use Standard Clic Box Drilling Patterns
-
REF: 230518
Step 3
Step 4
Step 5
Secure Profile Connectors to pre-drilled holes using
17mm screws.
Connect units by joining Profile
Connectors together.
Cut Rail Profiles to the overall height of the units
and Snap-On to Profile Connectors.
NOTE:
Recommended to
secure Tall units
together with
bracket on Top.
(not supplied)
Note: All Layouts Shown Use Standard Clic Box Drilling Patterns
-
REF: 230518
Wall Unit Installation:
*Note: Lengthen Plant-on Gables by 48mm to finish them flush with bottom of Profile Rail.
Components List:
Step 1 Step 2
Drill and secure Profile Connectors as
shown.
Cut Single Rail Profile to exact width of unit and
Snap-On to Profile Connectors.
Double Rail Single Rail
Door Height = Carcase Height + 16mm
Hinge Drillings - Door Drillings for Standard Wall
Unit with 100mm Drillings (Includes Clic Box)
• Door Top Hinge = 98mm
• Door Bottom Hinge = 116mm