gte service gmbh corporate presentation...of the conveyor systems and via local manual switch....

11
gte Service GmbH CORPORATE PRESENTATION

Upload: others

Post on 12-May-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: gte Service GmbH CORPORATE PRESENTATION...of the conveyor systems and via local manual switch. Category: Fire resistance class EI90 Scope of application: Model series 100E –EI90

gte Service GmbH

CORPORATE PRESENTATION

Page 2: gte Service GmbH CORPORATE PRESENTATION...of the conveyor systems and via local manual switch. Category: Fire resistance class EI90 Scope of application: Model series 100E –EI90

1

OUR AMBITIONSATISFIED CUSTOMERS

OUR PROMISERELIABLE SERVICE ANDGERMAN ENGINEERING SKILLS

Page 3: gte Service GmbH CORPORATE PRESENTATION...of the conveyor systems and via local manual switch. Category: Fire resistance class EI90 Scope of application: Model series 100E –EI90

2

INTRODUCTION

Fire protection systems are essential to protect human lives and material goods in case of fire.

A yearly maintenance required by law as well as repair measures ensure durable availibility and protection in an emergency.

The gte Service team is specialized in fire prevention of conveyors and ensures withits services for maximum safety at airports, manufactories and logistic centers.

We have more than 15 years of experience in our business, a great number of well-known companies as our customers and we maintain projects all over the world.

Page 4: gte Service GmbH CORPORATE PRESENTATION...of the conveyor systems and via local manual switch. Category: Fire resistance class EI90 Scope of application: Model series 100E –EI90

SERVICE PORTFOLIO

3

maintenancespare parts

servicetraining

gte Schoolreplacement of

control unitstechnicalopinion

Page 5: gte Service GmbH CORPORATE PRESENTATION...of the conveyor systems and via local manual switch. Category: Fire resistance class EI90 Scope of application: Model series 100E –EI90

MAINTENANCE

− Onetime or contract over 3 years - guaranteed pricestability over the whole contract period

− Scheduling at the end of a year for the following

− Service technicians on duty: Wuppertal, Berlin, Stuttgart, Hamburg, and Munich

5

Technical know-how and service for your safety, according to the european policy.

Page 6: gte Service GmbH CORPORATE PRESENTATION...of the conveyor systems and via local manual switch. Category: Fire resistance class EI90 Scope of application: Model series 100E –EI90

MAINTENANCE | BENEFITS

− Reliability performance for the maximum safety in case of fire

− Long working life and prevention of failures

− Preservation of insurance coverage and prevention of financialpenalties

6

Yearly maintenance according to law and safety-related terms

Compliance with documentary obligation and detailedmaintenance protocol

Compliance with building regulations (repair work)

Page 7: gte Service GmbH CORPORATE PRESENTATION...of the conveyor systems and via local manual switch. Category: Fire resistance class EI90 Scope of application: Model series 100E –EI90

7

HEIKO WÜSTENHAGENPurchasing/Spare Parts Management

Phone: + 49 (0) 3328 326 72 31Fax: + 49 (0) 3328 326 72 12E-Mail: [email protected]

SPARE PARTS SERVICE CONTACT

You can count on us in case of need.

− Quick solutions for less failure time

− Short delivery times (standard spare parts)

− Flexible coordination of necessaryrepair work

− Well-equipped and professional technicians

Page 8: gte Service GmbH CORPORATE PRESENTATION...of the conveyor systems and via local manual switch. Category: Fire resistance class EI90 Scope of application: Model series 100E –EI90

9

REPLACEMENT OF CONTROL UNITS

The control unit is an important part of yourfire protection system and essential for itsfunctionality.

An ongoing technical progress and new legal requirements cause changes and the need tomodernize old systems.

We can make sure that your fire protection system is always ready for use with an update of your control units.

Your control unit needs an update?

Page 9: gte Service GmbH CORPORATE PRESENTATION...of the conveyor systems and via local manual switch. Category: Fire resistance class EI90 Scope of application: Model series 100E –EI90

Our fire shutters are suitable for all industrial branches. They are planned and installed individually for your specific needs. All fire shutters can be made of stainless steel, if required.

In the area of conveyor technology our fire shutters are convenient both for intermittent and continuously conveyor systems, for example carrying chain-, belt-, and roller conveyor.

Normally the fire shutters will be kept open above the wall opening with help of the catch system (magnetic clamp).

In case of a fire alarm initiated by the built-in smoke detector, the fire shutters automatically fill in the gap of the conveyor systems.

If you choose the power-driven completion, all functionalities can be operated directly via control unit of the conveyor systems and via local manual switch.

Category: Fire resistance class EI90

Scope of application: Model series 100E – EI90

Sizes: max.width. 1500mm

max. height: 1500mm

(Large openings could require permission in individual cases)

Test regulations EN 1363-1 & EN 1366-7

Admission VKF No. 125596

Fire doors and gates

Space-saving fire shutters as a clap Characteristics

Page 10: gte Service GmbH CORPORATE PRESENTATION...of the conveyor systems and via local manual switch. Category: Fire resistance class EI90 Scope of application: Model series 100E –EI90

Our sliding doors are suitable for all industrial branches. They are planned and installed individually for your specific needs. All sliding doors can be made of stainless steel, if required.

In the area of conveyor technology our sliding doors are convenient both for intermittent and continuously conveyor systems, for example carrying chain-, belt-, and roller conveyor.

Normally the sliding doors will be kept open besides, above or under the wall opening with help of the catch system (magnetic clamp).

In case of a fire alarm initiated by the built-in smoke detector, the sliding doors automatically fill in the gap of the conveyor systems.

If you choose the power-driven completion, all functionalities can be operated directly via control unit of the conveyor systems and via local manual switch.

Category: Fire resistance class EI90

Scope of application: Model series 100E – EI90

Sizes: max.width. 3600mm

max. height: 3500mm

(Large openings could require permission in individual cases)

Test regulations EN 1363-1 & EN 1366-7

Admission VKF No. 18945

Fire doors and gates

Horizontal and vertical sliding doors Characteristics

Page 11: gte Service GmbH CORPORATE PRESENTATION...of the conveyor systems and via local manual switch. Category: Fire resistance class EI90 Scope of application: Model series 100E –EI90

CONTACT

gte Service GmbH P: + 49 (0) 202 963 118 00Administration F: + 49 (0) 202 963 118 11Baerenstrasse 11-13D-42117 Wuppertal [email protected] www.gteservice.de

gte Service GmbH P: + 49 (0) 3328 326 72 00Technical Office F: + 49 (0) 3328 326 72 12Hauptstrasse 6D-14979 Großbeeren [email protected] www.gteservice.de