gt sena/09hf/i sena/09hf/o sena/12hf/i sena/12hf/o z · sena/09hf/iz sena/09hf/oz sena/12hf/iz...

8
SENA/09HF/IZ SENA/09HF/OZ SENA/12HF/IZ SENA/12HF/OZ SENA/18HF/IZ SENA/18HF/OZ SENA/24HF/IZ SENA/24HF/OZ GT The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details.

Upload: others

Post on 13-Jul-2020

79 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: GT SENA/09HF/I SENA/09HF/O SENA/12HF/I SENA/12HF/O Z · SENA/09HF/IZ SENA/09HF/OZ SENA/12HF/IZ SENA/12HF/OZ SENA/18HF/IZ SENA/18HF/OZ SENA/24HF/IZ SENA/24HF/OZ GT

SENA/09HF/IZSENA/09HF/OZSENA/12HF/IZSENA/12HF/OZSENA/18HF/IZSENA/18HF/OZSENA/24HF/IZSENA/24HF/OZ

GT

The design and specifications are subject to change without prior notice forproduct improvement. Consult with the sales agency or manufacturer for detai ls.

Page 2: GT SENA/09HF/I SENA/09HF/O SENA/12HF/I SENA/12HF/O Z · SENA/09HF/IZ SENA/09HF/OZ SENA/12HF/IZ SENA/12HF/OZ SENA/18HF/IZ SENA/18HF/OZ SENA/24HF/IZ SENA/24HF/OZ GT

CONTENTS

SOCIABLE REMARK

DISPOSAL: Do not dispose of this product as unsorted municipal waste. Collectionof such waste separately for special treatment is necessary.

It is prohibited to dispose of this appliance in domestic household waste.For disposal, there are several possibilities:A) The municipality has established collection systems, where electronic waste can

be disposed of at least free of charge to the user.B) When buying a new product, the retailer will take back the old product at least

free of charge.C) The manufacturer will take back the old appliance for disposal at least free of

charge to the user.D) As old products contain valuable resources, they can be sold to scrap metal

dealers.Wild disposal of waste in forests and landscapes endangers your health whenhazardous substances leak into the ground-water and find their way into the foodchain.

When using this air conditioner in the European countries, please read thefollowing information:

SOCIABLE REMARK

SAFETY PRECAUTIONS

OPERATING INSTRUCTIONS

CARE AND MAINTENANCE

OPERATION TIPS

TROUBLESHOOTING TIPS

Sociable remark........ ...............................................................................................................2

Warning ................... ...............................................................................................................3Caution .................... ...............................................................................................................4

Parts names ........... ...............................................................................................................5Special functions ...... ...............................................................................................................6Operating temperature.............................................................................................................7Manual operation ..... ...............................................................................................................7Airflow direction control ..........................................................................................................8How the air conditioner works ................................................................................................9

Care and maintenance ........... ......................................... ......................................................10

Operation tips .......... .. ........... ......................................... ......................................................12

Troubleshoot ing tips .............. ......................................... ......................................................14

Contact the authorized installer for installation of this unit.Contact an authorized service technician for repair or maintenance of this unit.This appliance is not intended for use by persons(including children) with reducedphysical, sensory or mental capabilities, or lack of experience and knowledge, unlessthey have been given supervision or instruction concerning use of the appliance bypersons responsible for their safety.Young children should be supervised to ensure that they do not play with theair conditioner.If the power cord is to be replaced, replacement work shall be performed byauthorized personnel only.Installation work must be performed in accordance with the national wiringstandards by authorized personnel only.

CAUTION

Page 3: GT SENA/09HF/I SENA/09HF/O SENA/12HF/I SENA/12HF/O Z · SENA/09HF/IZ SENA/09HF/OZ SENA/12HF/IZ SENA/12HF/OZ SENA/18HF/IZ SENA/18HF/OZ SENA/24HF/IZ SENA/24HF/OZ GT

SAFETY PRECAUTIONS

To prevent injury to the user or other people and property damage, the following instructionsmust be followed. Incorrect operation due to ignoring of instructions may cause harm or damage.The seriousness is classified by the following indications.

This symbol indicates the possibility of death or serious injury.

Meanings of symbols used in this manual are as shown below.

WARNING

Always do this.

Never do this.

CAUTION This symbol indicates the possibility of injury or damage to property.

Connect with the powerproperly.

Do not modify power cordlength or share the outletwith other appliances

Always ensure effectivegrounding.

Disconnect the power ifstrange sounds, smell, orsmoke comes from it.

Ventilate room before operating airconditioner if there is a gas leakagefrom another appliance.

Otherwise, it may cause electricshock or fire due to heatgeneration.

excess

It may cause electric shockor fire due to heat generation.

No grounding may causeelectric shock.

It may cause fire andelectric shock.

It may cause explosion, fire and burns.

It may cause electric shock or firedue to heat generation.

It may cause electric shock.

It may cause failure ofmachine or electric shock.

It contains contaminants andcould make you sick.

It may cause fire andelectric shock.

It may cause electric shockor fire.

This could damage yourhealth.

No installation may causefire and electric shock.

It may cause electric shock.

It may cause explosion or fire.

It may cause failure andelectric shock.

Do not operate or stop theunit by switching on or offthe power.

Do not operate with wethands or in dampenvironment.

Do not allow water to runinto electric parts.

Do not drink water drainedfrom air conditioner.

Do not use the power cordclose to heating appliances.

Do not damage or use anunspecified power cord.

Do not direct airflow atroom occupants only.

Always install circuitbreaker and a dedicatedpower circuit.

Do not open the unitduring operation.

Do not use the power cord nearflammable gas or combustibles, suchas gasoline, benzene, thinner, etc.

Do not disassemble ormodify unit.

WARNING

Use the correctly ratedbreaker or fuse.

There is risk of fire orelectric shock.

SAFETY PRECAUTIONS

CAUTION

When the air filter is to beremoved, do not touch themetal parts of the unit.

It may cause an injury.

Do not clean unit whenpower is on as it may causefire, electric shock or injury.

Operation with windowsopened may cause wettingof indoor and soaking ofhousehold furniture.

When the unit is to becleaned, switch off, and turnoff the circuit breaker.

Stop operation and closethe window in storm orhurricane.

Use caution when unpackingand installing. Sharp edgescould cause injury.

Water may enter the unit anddegrade the insulation. It maycause an electric shock.

This could injure the pet orplant.

Do not put a pet or houseplant where it will beexposed to direct air flow.

Ventilate the room wellwhen used togetherwith a stove, etc.

An oxygen shortagemay occur.

Do not use this air cond-itioner to preserve preci-sion devices, food, pets,plants, and art objects.It may cause deteriorationof quality, etc.

It may cause failure ofproduct or fire.

Do not use forspecial purposes.

Turn off the main powerswitch when not singthe unit for a long time.

u

If water enters theunit, turn the unit offand disconnect thepower , contact aqualified servicetechnician.

It may cause failure ofappliance or accident.

Appearance may bedeteriorated due to changeof product color orscratching of its surface.

Do not place obstaclesaround air-inlets or insideof air-outlet.

Do not use strong detergentsuch as wax or thinner. Usea soft cloth for cleaning.

If bracket is damaged, thereis concern of damage due tofalling of unit.

There is danger of fire orelectric shock.

Ensure that the installation bracket ofthe outdoor appliance is not damageddue to prolonged exposure.

Do not place heavy object on thepower cord and take care so thatthe cord is not compressed.

Operation without filtersmay cause failure.

Always insert the filterssecurely. Clean filteronce every two weeks.

Do not clean the airconditioner with water.

Do not put objects like thinrods into the panel of blowerand suction side.

The high-speed fan insidemay cause danger.

Page 4: GT SENA/09HF/I SENA/09HF/O SENA/12HF/I SENA/12HF/O Z · SENA/09HF/IZ SENA/09HF/OZ SENA/12HF/IZ SENA/12HF/OZ SENA/18HF/IZ SENA/18HF/OZ SENA/24HF/IZ SENA/24HF/OZ GT

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS

8. Connecting9. Connecting10. Stop valve

pipecable

Outdoor unitOutdoor unit

LED Display WindowIndication lamp on LED Display window

NOTE: The actual shape of the indoor unityou purchased may be slight differenton front panel and display window.

NOTE: The display on the indoor un ityou purchased may look like one ofthe following:

1. Front panel2. Air inlet3. Air filter4. Air outlet5.6.7. Display panel

Horizontal air flow grilleVertical air flow louver(inside)

Indoor unitIndoor unit Special functions

This air conditioner is equipped with ionizer or Plasma Dust Collector(Depending on specificconfigurat ion of the model). With the anions generated by Ionizer, the air circulation of the aircondit ioner fills the room with refreshing, natural and healthy air. The Plasma Dust Collectorgenerates a high voltage ionization zone, through which the air is converted to plasma. Insidethe air most of the dust, smoke, and pollen particles are captured by the electrostatic f ilter.

FRESH function(on some models)

SELF CLEAN function( )Optional

Refrigerant Leakage Detection

Anti-mildew function( )OptionalWhen turns off the unit on COOL, DRY, AUTO (Cool) mode, the air conditioner will continueoperating for about 7-10 minutes (depending on models) with soft wind. This will help todry up the condensed water inside the evaporator, and prevent the breeding of mildew.Under Anti-mildew operation, do not restart the air conditioner until the unit is completely off.

Louver Angle Memory Function(optional):Within the scope of safety angle, it will memorize the open angle of horizontal louver. Ifit exceeds, it will memorize the boundry of safety angle. In the following circumstances,it will return to standard angle: 1) pressing the turbo or manual control button, 2)unplugand then plug in the machine. So we strongly suggest that the open angle of the horizontallouver should not be set too small, in c ase the condensed water forms and drops from thehorizontal louver.

NOTE:All the pictures in this manual are forexplanation purpose only. Your airconditioner may be slightly different.The actual shape will prevail.

Vertical swing function( )OptionalAfter the AC starts up, users can control the vertical louver swing by the remote controller.

9

10

8

RUN indication lampThis lamp illuminates when the airconditioner is in operation.

FRESH indication lamp(optional function)This lamp illuminates when CleanAir feature is activated.

TIMER indication lampLights up during Timer operation.

DEFROST indication lamp(Applicable to cooling & heating models only):

when the air conditioner startsdefrosting automatically or when the warmair control feature is activated in heatingoperation.

Lights up

Temperature indicatorDisplays the temperature settings when theair conditioner is operational.Displays the malfunction code.

With this new technology, the dipsplay area will appear EC or the LED indication lampskeep flashing (depending on models) when the outdoor unit detects refrigerant leakage.

,,

Function used after the Shut Down of cooling operation to clean the Evaporator and keep itas fresh for the next operation.The unit wil l operate as following sequence : FAN ONLY mode at Low fan speed--Heatingoperation with LOW fan speed(applicable to c ooling & heating modles only) ---FAN ONLYoperation--Stop Operation---Turn off .

This function is only available under COOL(AUTO COOL, FORCED COOL) and DRY mode.Before selec t the function, it is recommended to run the air conditioner under Coolingoperation for about half an hour.Once the Self Clean function is activa ted, all T IMER setting wi l l be cancelled.Dur ing Self Clean operation, when press the SELF CLEAN button on the remote contro lleraga in will stop the operation and turn off the unit automatically.

Note:

( )A

( )B

fresh defrost run timer

fresh defrost run timer

Page 5: GT SENA/09HF/I SENA/09HF/O SENA/12HF/I SENA/12HF/O Z · SENA/09HF/IZ SENA/09HF/OZ SENA/12HF/IZ SENA/12HF/OZ SENA/18HF/IZ SENA/18HF/OZ SENA/24HF/IZ SENA/24HF/OZ GT

OPERATING INSTRUCTIONS

Airflow direction controlAdjust the air flow direction properly otherwise itmight cause discomfort or cause uneven roomtemperatures.Adjust the horizontal/vertical louver using the remotecontroller. For some models, the vertical louver canonly be adjusted manually.

Perform this function while the unit is in operation.Use the remote controller to adjust the air flow direction.The vertical/horizontal louver changes 6 degree in anglefor each press, or swing up and down automatically.Please refer to the REMOTE CONTROLLER OPERATIONMANUAL for details.

To set the horizontal/vertical air flow direction

For some models, the vertical louver can only be adjustedmanually. Move the deflector rod manually to adjust the airflow in the direction you prefer.

:Do not put your fingers into the panel ofblower and suction side.IMPORTANT

The high-speed fan inside maycause danger.

Do not operate the air conditioner for long periods withthe air flow direction set downward in cooling ordehumidifying mode. Otherwise, condensation mayoccur on the surface of the horizontal louver causingmoisture to drop on to the floor or on furnishings.When the air conditioner is started immediately after itwas stopped, the horizontal louver might not move forapproximately 10 seconds.Open angle of the horizontal louver should not be settoo small, as COOLING or HEATING performance maybe impaired due to too restricted air flow area.Do not move the horizontal louver manually, otherwisethe horizontal louver will be out of sync. Please ceaseoperating, unplug power for a few seconds,then restartthe air conditioner.Do not operate unit with horizontal louver in closedposition.

CAUTION

,,

,,

Manual operation can be used temporarily in case the remote controller is disable orthe unit requires maintenance.

OPERATING INSTRUCTIONS

Manual operation

NOTE: This manual does not include Remote Controller Operations, see the<<Remote Controller Instruction>> packed with the unit for details.

Operating temperature

Open and lift the front panel up to an angleuntil it remains fixed with a click ing sound.For some models, please use suspensionbars to prop up the panel.

Close the panel firmly to its originalposit ion.

One press of the manual control button willlead to the forced AUTO operation. If pressthe button twice within five seconds, the unitwill operate under forced COOL operation.

This button is used for testing purposesonly. You had better not choose it.To restore the remote controller operation,use the remote control ler directly.

CAUTION:

1

3

2

NOTE: The unit must be turned off beforeoperating the manual control button. If theunit is operational, continue pressing themanual control button until the un it is off.

ModeTemperatureRoom temperature

Outdoor temperature

1. Optimum performance wil l be achieved within these operating temperatures.If airconditioner is used outside of the above conditions, certain safety protection featuresmight come into operation and cause the unit to function abnormally.

2. Room re lative humidity less than 80%. If the air conditioner operates in excess of thisfigure, the surface of the air conditioner may attract condensation. Please sets the verticalair flow louver to i ts maximum angle (vertically to the floor), and set HIGH fan mode.

Suggestion: For the unit adopts an Electric Heater, when the outside ambient temperatureis below 0 C(32 F), we strongly recommend you to keep the machine plugged in order to

guarantee it running smoothly.

O O

NOTE:

Cooling operation Heating operation Drying operation

17 62

-15 50 5 122For the models with low

temperature cool ing system

0 5032 122

30 86

-15 305 86

10 50

0 5032 122

Deflector rod

Range

Range

Manual controlbutton

AUTO/COOL

Suspension bars

AUTO/COOL

( )1

( )2

Manual controlbutton

Page 6: GT SENA/09HF/I SENA/09HF/O SENA/12HF/I SENA/12HF/O Z · SENA/09HF/IZ SENA/09HF/OZ SENA/12HF/IZ SENA/12HF/OZ SENA/18HF/IZ SENA/18HF/OZ SENA/24HF/IZ SENA/24HF/OZ GT

Cleaning the Grille, Case and Remote Controller

A cloth dampened with cold water may be usedon the indoor unit if it is very dirty. Then wipe itwith a dry cloth.Do not use a chemically treated cloth or duster toclean the unit.Do not use benzine, thinner, polishing powder, orsimilar solvents for cleaning. These may causethe plastic surface to crack or deform.Never use water hotter than 40 C/104 F to cleanthe front panel, it could cause deformation ofdiscoloration.

CAUTIONS

CARE AND MAINTENANCE

Care and Maintenance

Turn the system off before cleaning. To clean, wipe witha soft, dry cloth. Do not use bleach or abrasives.NOTE: Power supply must be disconnectd beforecleaning the indoor unit.

A clogged air filter reduces the cooling efficiency ofthis unit. Please clean the filter once every 2 weeks.1. Lift the indoor unit panel up to an angle until it

stops with a clicking sound.For some models,please use suspension bars to prop up the panel.

2. Take hold of the handle of the air filter and lift itup slightly to take it out from the filter holder,then pull it downwards.

3. Remove the AIR FILTER from the indoor unit.Clean the AIR FILTER once two weeks.Clean the AIR FILTER with a vacuum cleaneror water, then dry it up in cool place.

Cleaning the air filter

OPERATING INSTRUCTIONS

How the air conditioner works

1 hour1 hour

SetTemperature

SetTemperature

Cooling

Heating

SLEEP operation

1 hour 1 hour

SLEEP operation7 hours timer o ff

7 hours timer off

NOTE: Power supply must be disconnectd beforecleaning the indoor unit.

AUTO operation

SLEEP operation

DRYING operation

Optimal operation

When you set the air conditioner in AUTO mode, it willautomatically select cooling, heating(cooling/heatingmodels only), or fan only operation depending on settemperature and the room temperature.The air conditioner will control room temperatureautomatically to the temperature point you set.If you feel uncomfortable in the AUTO mode, you can setyour desired temperature.

When you push SLEEP button on remote controllerduring cooling, heating(cooling & heating models only),or AUTO operation , the air conditioner willautomatically increase (cooling) or decrease (heating)

per hour for the first 2 hours, then holdsteadily for the next 5 hours, after that it will switch off.This mode saves you energy and brings you comfortat night.

To achieve optimal performance, please note thefollowing:Adjust the air flow direction correctly so that it is notforwards people.Adjust the temperature to achieve the highest comfortlevel. Do not adjust the unit to excessive temperaturelevels.Close doors and windows on COOL or HEAT modes,or performance may be reduced.Use TIMER ON button on the remote controller toselect a time you want to start your air conditioner.Do not put any object near air inlet or air outlet, as theefficiency of the air conditioner may be reduced andthe air conditioner may stop running.Clean the air filter periodically, otherwise cooling orheating performance may be reduced.Do not operate unit with horizontal louvre in closedposition.

The fan speed will be automatically controlled underdry operation.During the dry operation, if the room temperature islower than 10 C(50 F), the compressor stops operationand restarts until the room temperature is above12 C(54 F).

O O

O O

Filter Handle

Page 7: GT SENA/09HF/I SENA/09HF/O SENA/12HF/I SENA/12HF/O Z · SENA/09HF/IZ SENA/09HF/OZ SENA/12HF/IZ SENA/12HF/OZ SENA/18HF/IZ SENA/18HF/OZ SENA/24HF/IZ SENA/24HF/OZ GT

OPERATION TIPS

The following events may occur during normal operation.1.

The compressor can't restart for 3 minutes after it stops.

The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is inone of the following three situations and the set temperature has not been reached.A) When heating has just started.B) Defrosting.C) Low temperature heating.The indoor or outdoor fan stop running when defrosting (Cooling and heating models only).

Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is lowand humidity is high resulting in lower heating efficiency of the air conditioner.During this condition air conditioner will stop heating operation and start defrosting automatically.The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature andthe amount of frost built up on the outdoor unit.

2.A white mist may generate due to a large temperature difference between air inlet and air outleton COOL mode in an indoor environment that has a high relative humidity.A white mist may generate due to moisture generated from defrosting process when the airconditioner restarts in HEAT mode operation after defrosting.

3.You may hear a low hissing sound when the compressor is running or has just stopped running.It is the sound of the refrigerant flowing or coming to a stop.You can also hear a low "squeak" sound when the compressor is running or has just stoppedrunning. This is caused by heat expansion and cold contraction of the plastic parts in the unitwhen the temperature is changing.A noise may be heard due to louver restoring to its original position when power is turned on.

4.This is a normal condition when the air conditioner has not been used for a long time or during firstuse of the unit.

5.This is caused by the indoor unit giving off smells permeated from building material, from furniture,or smoke.

Protection of the air conditioner.Compressor protection

Anti-cold air (Cooling and heating models only)

Defrosting (Cooling and heating models only)

A white mist coming out from the indoor unit

Low noise of the air conditioner

Dust is blown out from the indoor unit.

A peculiar smell comes out from the indoor unit.

6.

When indoor temperature reaches the temperature setting on air conditioner, the compressor willstop automatically, and the air conditioner turns to FAN only mode. The compressor will start againwhen the indoor temperature rises on COOL mode or falls on HEAT mode (For cooling and heatingmodels only) to the set point.

7.

The air conditioner turns to FAN only mode from COOL or HEAT (For cooling andheating models only) mode.

The air conditioner runs function after turning off the unit.When turning off the unit under COOL(AUTO COOL, FORCED COOL) and DRY mode,the airconditioner will run function for 7-10 seconds, then stop the operation and turnoff the unit automatically.

Anti-mildew

Anti-mildew

CARE AND MAINTENANCE

Maintenance

Checks before operation

If you plan to not use the unit for a long time, performthe following:(1) Clean the indoor unit and filters.

Operate the fan for about half a day to dry theinside of the unit.Stop the air conditioner and disconnect power.

(4)The outdoor unit requires periodic maintenanceand cleaning. Do not attempt to do this yourself.Contact your dealer or service provider.

(2)

(3)Remove the batteries from the remote controller.

Check that the wiring is not broken off ordisconnected.Clean the indoor unit and filters.Check that the air filter is installed.Check if the air outlet or inlet is blocked after theair conditioner has not been used for a long time.

Do not touch the metal parts of the unit whenremoving the filter. Injuries can occur whenhandling sharp metal edges.Do not use water to clean inside the air conditioner.Exposure to water can destroy the insulation,leading to possible electric shock.When cleaning the unit, first make sure that thepower and circuit breaker are turned off.Do not wash with hot water at more than 40 .Shake off moisture completely and dry it in theshade; do not expose it directly to the sun.Thefilter may shrink.

Caution

4. Remove the Air Freshening Filters from its supportingframe (The solution to disassemble may differ fromeach other for different filters. Refer to and ).Clean the air freshening filter at least once a month,and replace it every 4-5 months.Clean it with vacuum cleaner, then dry it in cool place.For the models with plasma, do not touch the plasmawithin 10 minutes after you open the panel.

5. Install the air freshening filter back into position.6. Insert the upper portion of air filter back into the

unit, taking care that the left and right edges line upcorrectly and place filter into position.

1

2

1 2

Plasma

Air filter

Hold the two parts of Plasma where aremarked with signal and lift it. Then youcan open the cover of the the plasma andremove the filter.

Page 8: GT SENA/09HF/I SENA/09HF/O SENA/12HF/I SENA/12HF/O Z · SENA/09HF/IZ SENA/09HF/OZ SENA/12HF/IZ SENA/12HF/OZ SENA/18HF/IZ SENA/18HF/OZ SENA/24HF/IZ SENA/24HF/OZ GT

TROUBLESHOOTING TIPS

Troubleshooting Tips

Malfunctions

Unit does notstart

Unit not coolingor heating(Cooling/ heatingmodels only)room very wellwhile air flowingout from the aircond tioneri

Cause

Power cut

Unit may have become Unplugged.

Fuse may have blown.

Battery in Remote controller mayhave been exhausted.

The time you have set with timeris incorrect.

Wait for power to be restored.

Check that plug is securely in wallreceptacle.

Replace the fuse.

Replace the battery.

Wait or cancel timer setting.

Set temperature correctly. Fordetailed method please refer to" "Using remote control section.

Clean the air filter.

Close the doors or windows.

Clear obstructions away first, thenrestart the unit.

Wait.

Inappropriate temperaturesetting.

Air filter is blocked.

Doors or Windows are open.

Air inlet or outlet of indoor oroutdoor unit has been blocked.

Compressor 3 minutesprotection has been activated.

If the trouble has not been corrected, please contact a local dealer or the nearest customerservice center. Be sure to inform them of the detailed malfunctions and unit model number.

Notes: Do not attempt to repair the unit yourself.Always consult an authorized service provider.

What should be done?

8. Dripping water may generate on the surface of the indoor unit when cooling in a highrelatively humidity (relative humidity higher than 80%). Adjust the horizontal louver tothe maximum air outlet position and select HIGH fan speed.

9.The air conditioner draws in heat from the outdoor unit and releases it via the indoor unitduring heating operation. When the outdoor temperature falls, heat drawn in by the airconditioner decreases accordingly. At the same time, heat loading of the air conditionerincreases due to larger difference between indoor and outdoor temperature. If acomfortable temperature can't be achieved by the air conditioner, we suggest you use asupplementary heating device.

10.Power failure during operation will stop the unit completely.For the unit without Auto-restart feature, when the power restores, the OPERATION indicatoron the indoor unit starts flashing. To restart the operation, push the ON/OFF button on theremote controller. For the unit with Auto-restart feature, when the power restores, the unitrestarts automatically with all the previous settings preserved by the memory function.

11. Lightning or a car wireless telephone operating nearby may cause the unit to malfunction.Disconnect the unit with power and then re-connect the unit with power again. Push theON/OFF button on the remote controller to restart operation.

Heating mode (For cooling and heating models only)

Auto-restart function

OPERATION TIPS

If one of the following faults occurs, stop the air conditioner immediately, disconnect the powerand then connect it in again. If the problem still exists, disconnect the power and contact thenearest customer service center.

Fuse blows frequently or circuit breaker trips frequently.

Other objects or water fall into the air conditioner.

The remote controller won't work or works abnormally.

Trouble

OPERATION indicator or other indicators continue flashing.

If one of the following code appears on the display area :E0,E1,E2,E3.....or P0,P1,P2,P3......