GRUNDFOS Management A/SPoul Due Jensens Vej 7 DK-8850 BjerringbroTel: +45 87 50 14 00
www.grundfos.com
The Oxiperm Pro offers superior water disinfection technology for all types of water systems. It has the following, unique features:• Destroysbothfreebacteriaandbiofilm• Useschlorinedioxide,whichisextremelyefficient,buthasnoeffectonthetasteandsmellofthewater
• TherobustdesignoftheOxipermProensureshighoperationalreliabilityandlowmaintenancecosts
• User-friendlyoperation• Easyinstallationwithnointerruptionofthebuilding’swatersupply
GRUNDFOS OXIPERM PROsupreme Water disinfection
aLL round cHLorine dioXide soLutions
GRUNDFOS OXIPERM PRO
9697
4125
040
9
The GRUNDFOS OxipeRm pRO SySTem eNSUReS eFFecTive DiSiNFecTiON OF waTeR iN a SeRieS OF applicaTiON aReaSWater disinfection is of great importance in all buildings with drinking water consumption, and particularly in buildings that supply shower and bathing facilities. Water disinfection is also essential in applications where water mist is sprayed into the air, for instance cooling towers and evaporative condensers.
Grundfos’ Oxiperm Pro system ensures safe, clean water to all its end users in buildings such as:• Hotels• Hospitals• Sportsandswimmingfacilities• Fitnesscentres• Wellnessresorts• Residentialbuildings
The problemNaturally,thewaterwedrinkandshowerinhastobecleanifwearetostayhealthy.Unfortunately,oneofthe most widespread health hazards in drinking water installations worldwide is connected to exceptionally resistantbacteria–legionella.
Legionella exist mainly in hot water systems with a lowflowrate,areasofstagnationorbadlyservicedhot water tanks. A layer of slime in the water pipes calledbiofilmisthehabitatforlegionellaandothermicroorganisms.Thebacterialive,breedandthriveinbiofilmintemperaturesbetween30and50°Candtheyconstituteaseverehealthrisk.
The solutionThe Grundfos Oxiperm Pro system is the all round solutiontothehazardofbothlegionellaandotherkinds of micro organisms. It offers the following uniquebenefitsthatremainunmatchedbyotherdisinfection methods: •Worksonbothbacteriaandbiofilm•Affectshighlychlorineresistantgerms•Efficientinareasofthepipesystemwith no flow (dead ends) •Noeffectonthetasteandsmellofthewater•Sustainedreleaseeffectforlong-termdisinfection
OXIPERM PRO introduction
leGiONella cONTROl beGiNS heRe
Worldwide drinking water regulations require clean and healthy water free of:• Bacteria(legionella,salmonellaetc.)• Viruses(hepatitis,polio,norovirusetc.)• Parasites(giardia,cryptosporidium,entamoebaetc.)• Fungusspores(yeast,mouldsetc.)
Drinking water regulations
What are legionella bacteria?Legionellabacteriaaretheprimarysourceoflegionnaire’sdisease–apotentiallyfataldisease,particularly for those with a weakened immune system.Itisestimatedthatlegionnaire’sdiseaseisresponsiblefor15-20,000deathsinEuropeeveryyear.∗
Legionellabacteriaandthebiofilmwheretheyliveand feed are highly resistant to most disinfection methods.Thatmakeseffectivecombatagainstthemdifficult,andtheirsuccessfuleliminationcallsforspecificandhighlyspecialisedsolutions.
The right solution is both tough and gentleTherearemanyapproachestofightinglegionellabacteriaandbiofilm,butnoapproachisasefficient or gentle as the Grundfos Oxiperm Pro system. Thesystemeffectivelybattleslegionellaandbiofilmwithout affecting the taste and smell of the water. BychoosingOxipermPro,youhavemadetheright choice for the safety and comfort of the end consumers.
∗ Source:RobertKochInstitute,Berlin,2008
TOUGh pROblem – GeNTle SOlUTiON
OXIPERM PRO disinfection facts
Characteristics of typical disinfection solutions
Legionellapneumophila;theprimarysourcetolegionnaire’sdisease.
residual germs with
residual germswith hypochlorite (HClO)
00,01 0,02 0,03 0,04 0,05 0,06
20
40
60
80
100
Resi
dual
ger
ms [
%]
Concentration of disinfectant [mg/l]
pH > 7.5
Comparison of the disinfecting action of chlorine dioxide and hypochlorite at a pH of 7,5.
Comparison of the disinfectant action
Thermal treatment
UV radiation
Filtration
Chlorination (hypochlorite sol.)
Ozone
Rem
oves
bio
film
Benefits
Dis
infe
ctio
n pr
inci
ple
Effec
tive
aga
inst
bac
teria
in b
iofil
m
Effec
tive
aga
inst
free
bac
teria
Affec
ts w
ater
tast
e an
d sm
ell
Sens
itiv
e to
wat
er-p
H
Life
cyc
le c
ost
Use
r sca
ldin
g ris
k
Long
-ter
m e
ffec
t
Chlorine dioxide
= Inferior
= Average
= Superior
No No
No
No
No
Low Mid No No High Yes
No No NoHigh No Mid No
No No No No No Mid
Mid
No
No Mid High Yes Yes Low No
No No NoHigh No Low No
HighYes High NoHigh No Low No
This chart illustrates how the typical solutions for disinfection performonanumberofparameters. The chlorine dioxide solution of the Oxiperm Pro system is superior to the rest.
OXIPERM PRO tHe Benefits
The chemistry of great benefitsThe Oxiperm Pro system uses chlorine dioxide for the disinfection of water. This particular chemical compoundpresentsanumberofadvantagesthatcannotbematchedbyanyotherdisinfection method.
RemovesbothfreelegionellaandbiofilmLegionellabacteriagrowandreproduceinbiofilmasdoes90%ofallbacteriainwatersystems.Biofilmisalayerofslimethatexistsinwaterpipesandespeciallyinhotwatertanks.Chlorinedioxidediffusesintothebiofilmanddestroysitfromwithin,whereasotherdisinfectantsonlyattackthesurfaceofthefilm.
No effect on water taste and smellChlorinedioxidedoesnotformthetoxicchloraminesandhaloformsthatareaby-productofchlorine-baseddisinfectionmethods.Ineffect,thewaterneither tastes nor smells of chlorine with the use of the Oxiperm Pro.
Long-term effectChlorinedioxidehasthebestresidualeffectofalltheavailabledisinfection methods. It stays in thewatersystemforseveraldays,reachesintoeverycrackofthepipefittings,andevendissolvesintodead-endpipeswithnowaterflow.
Digital dosingThe Oxiperm Pro is a digital dosing systemwhichmakesitflexible,costeffectiveandeliminatestheriskofoverdosing.
Compact designTheOxipermProhasabuilt-inmeasuringapplication,which measures the residual chlorine in the water. It also has an integrated digital dosing pump making itanall-in-onecompactsolution.
WaterpHadaptableWithchlorinedioxide,noparticular pHvalueisneeded,whichmakesit anextremelyflexibledisinfectant.
Low life cycle costWaterdisinfectionwiththeOxipermPromeansreduced chemical use and reduced energy consumption. The chemical use is reduced due to theadvancedbatch-reaction-technologyandthehigh-precisionflowmeasurementsthatadjusttheamountofchemicalstothecurrentflowgivingtheOxipermProanextremelylowoveralllifecyclecost.
OXIPERM PRO siZinG
Typicaldosingratesinbuildingapplicationsarebetween0,1and0,4g/m³.
The exact quantity of required chlorine dioxide isdefinedbytestingon-site.Samplesaretakenfromthevariouswateroutletsinthebuildingand tested for chlorine dioxide residual. Based on the residual amount, the unit settings can beadjusted.ContactyourlocalGrundfosofficeforadetailedoverviewoftheguidelinesandregulationsrelevanttoyourproject.
cONceNTRaTiON
10
543
2
1
0,50,40,3
0,2
0,11 2 3 4 5 10 20 30 40 50 100
CI0 2
conc
entr
atio
n [g
/m³]
m3/hQpeak
Oxiperm OCD 162-10
Oxiperm OCD 162-5
Example: 200 room hotel Oxiperm Pro 5 should be used for disinfection of hot water only
Example: 200 room hotel Oxiperm Pro 10 should be used for disinfection of both hot and cold water only
Selectionchart
Note:MaximumconcentrationofCI0₂addedtodrinking water depends on national guidelines and regulations.
Quick glance flow chart, Qpeak
The required total consumption and maximum flow requirementdependsonthebuildingtype.Thereisabigdifferenceinannualwaterconsumption,dailymaximum consumption and the peak consumption inablockofflatscomparedtoafivestarhotel.Ifyouhavenoreliableflowmeasurementsinthebuilding,thetablebelowgivesyouanexampleofhowtocalculatepeakwaterflowinvarioustypesofbuildingsin order to select the right Oxiperm Pro.
FlOw
11 10 20 50 100 200 500 1000 2000 5000 10000 20000
2
4
6810
20
40
6080100
200
400
6008001000
Qpeak
[m³/h]
Units
Hotel
Residentia
l build
ing
Office
School
Example of calculation of maximum hourly flow rate in a 200-bed hotel Annual water consumption: Qyear=180m3/bed/yearConsumptionperiod:365days/yearAveragedailyconsumption:Qavg=180/365=0,5m3/bed/dayDayfactor:fd = 1,5Maximum daily flow rate: Qmax = 0,5 x 1,5 = 0,75 m3/bed/dayPeak factor: fp = 4Maximum hourly flow rate per unit: Qpeak=0,75x4/24=0,125m3/bed/hNumberofbeds:n=200Maximum hourly flow rate for the whole hotel: Qpeak = 200 x 0,125 = 25 m3/h(hotandcoldwater)Maximum hourly flow rate for the whole hotel: Qpeak = 25 x 0,4 = 10 m3/h(hot water only)
Alternatively,usethequickglanceflowcharttotheright.
Defining peak flow, Qpeak
AbovefiguresareassumptionsbasedonDanishlegislationDS442/1989CodeofPracticeforcommonwater-works.Calculationofwaterflowetc.mayvaryfromcountrytocountrydependingonnationalguidelinesandlegislation.
Building Unit Qyear Consumption period Qavg fd Qmax fp Qpeak type [m per year] [days/year] [m/unit/day] [m/unit/day] [m/unit/h]
Residentialbuilding Residents(2,5pers.) 183 365 0,5 1,3 0,65 1,7 0,046
Officebuildings Employee 25 250 0,1 1,2 0,12 3,6 0,018
Shoppingcentre Employee 25 300 0,08 1,2 0,1 4,3 0,018
Supermarket Employee 80 300 0,27 1,5 0,4 3,0 0,050
Hotel Bed 180 365 0,5 1,5 0,75 4,0 0,125
Hospital Bed 300 365 0,8 1,2 1,0 3,0 0,120
School Pupil 20 200 0,1 1,3 0,13 2,5 0,014
OXIPERM PRO tHe Water system
HOTWATERTANK
INJECTION POINTHOT AND COLD WATER
HOT WATER
HOT WATER, CIRCULATION
COLD WATER MUNICIPAL WATER MAIN
INJECTION POINT.HOT WATER ONLY
Injectionofchlorinedioxideintothewatersystemcanbedonewhereveritisdeemedsuitable.Ifatotaldisinfectionisdesired,theinjectionpointshouldbelocatedwherethewatermainentersthebuilding.
Inmostcases,itissufficienttotreatonlythehotwater system where there is the highest risk of bacteriagrowth.
iNjecTiON pOiNTS
Afivestarhotelmustdelivertheveryhighestlevel of comfort and safety for its guests. Le Meridien BristolinWarsawopenedin1993andreliedontheexpertise of Grundfos for all its installations. Grundfosprovidedcirculationpumps,boosters andwastewaterpumps.Toensuretheguests’protectionfromlegionellabacteria,thehotelchose to install the Oxiperm Pro. As a result, the hotel cancontinuetoprovideworld-classservice,andthehealth and safety of its guests is secured.
le meRiDieN bRiSTOl – Five STaR hOTel iN waRSaw
HClNaCIO²
Waterpipe/tube
ClO₂dosingline
Signalline
OXIPERM PRO tHe detaiLs
Main water lineWaterflowtobetreatedwith chlorine dioxide
Supplywaterout-takeWatersupplyforOxipermPro
Sodiumchloritestorage tank30litresstandardcontainer
Water meterProvidesimpulseoranaloguesignalforproportional dosing of chlorine dioxide
Chlorine dioxide measurementMeasurement module that controls the chlorine dioxide residual in treated water
Samplewaterre-feedSamplewaterforchlorinedioxidemeasurementisre-fedtoavoidunnecessary water consumption
Injection pointDosingpointofchlorinedioxide solution in water line
Drip pansContainmentforchemicaltankstoavoidchemicalspilling
Samplewaterout-takeSamplewaterformeasurementofchlorine dioxide residual
Hydrochloricacidstorage tank30litresstandardcontainer
ThiNkiNG bUilDiNGSAtGrundfosCBS,wearealwaysthinkingbuildings,andourproductscontributetomakingbuildingsthatcanalmostthinkforthemselves.Wedonotjustconsiderourproductsasstandalonedevices–weconsiderthemanintegralpartofalivingbuildingwhosepurposeistofunctioninthebestwaypossibleforitsinhabitants.
GrundfosCBSoffersproductsacrossthefullrangeofapplications, including heating, air conditioning, waste water,boostersystems,fireprotectionsystemsanddistrict energy.
Ourexpertiseisfoundedindecadesofglobalexperience and we are proud to share our knowledge withourclients.Wearealsodeterminedto taketheleadonnewtechnologiesandinnovationopportunities.
TolearnmoreaboutGrundfosCBSandtofindouthowwecanbeofassistance,contactGrundfos orvisitusatwww.grundfos.com/commercialbuilding.
explORe OUR ONliNe UNiveRSe
OXIPERM PRO tecHnicaL data
Technical data
Chlorinedioxidegenerationcapacity OCD-162-5 5mg/l OCD-162-10 10mg/l
Adjustmentofthepreparationcapacity manualbymenu-controlledoperatorprompting, automaticbyinputsignal
Protectionlevel IP65 electronics,dosingpumps,solenoidvalve
Requiredconcentrationofchemicals •HCI(toEN939) 9%byweight
•NaCIO₂(toEN938) 7,5%byweight
Admissible •ambienttemperature 5-35°C •operationwatertemperature 10-30°C •chemicalstemperature 10-35°C
Admissibleoperationwaterpressure 3to6bars
Admissiblerelativeairhumidity max80%at35°C,notcondensing
Concentrationofthechlorinedioxide productsolution ca.2g/l(2000ppm)
Material system rack PP fasteningsleeves stainlesssteel solenoidvalve PVC reaction/storagetank PVC internalhoses PTFE gaskets FPM
Fulltextmenucontrolfor •commissioning •enteringoperatingparameters •rinsingthesystem •maintenance
Connections dosinglineCIO₂ 230Vhose4/6” 115Vhose1/8”x1/4” dilutionwater 230Vhose6/9”or6/12”orPVCpipeDN10 115Vhose1/4”x3/8”
Electrical and electronic data
Mainsconnection 110/120V/50-60Hzor230/240V/50-60Hz
Powerconsumption ca.50VA
Analogueinput •input0(4)-20mA(watermeter) •measuringcell(CIO₂pHorRedox,temperature)(option)
Digitalinput •contactwatermeter(min.3pulses/min.,max.50pulses/sec) •remoteOn/Off
Analogueoutput •output0(4)-20mA(pumpregulation) •measuredvalueCIO₂0(4)-20mA
Potential-freeoutput •alarmrelay,250V/6A,max.550VA (chemicals empty signal, dosing time monitoring, preparation process timemonitoring,wirebreakcurrentoutput) •warningrelay,250V/6A,max.550VA (chemicalsemptypre-alert,maintenance) •CIO₂dosingpump
MakethemostofGrundfosCBS –visittheThinkingBuildingsUniverseatwww.grundfos.com/commercialbuilding. Ourwebsitecontainsarangeofservicesthat functionasyouronlineGrundfosCBSexpert:
• QuickPumpSelectionwithanextensive product database and dimensioning tool that helps you choose the right pump for your needs