group gc2 - inverters r us

2
DEEP CYCLE AGM PREMIUM DEEP CYCLE SERIES | fullriverbattery.com DC250-6 GROUP GC2 BATTERY & TERMINAL DIMENSIONS (All units shown in mm) 250 Amp Hours 20 Hour Rate CYCLING CAPACITY RESERVE CAPACITY - All listed ratings are @ 100% SoC, T=77°F (25°C), 1.75VPC unless otherwise specified. - Specifications listed are for estimation purposes only. Battery performance can vary depending on application. Battery design subject to change. (unit: mm) 6 Volt 1.6m ELECTRICAL SPECIFICATIONS Nominal Voltage 275AH C100 250AH C20 229AH C10 204AH C5 960 CCA 1160 CA or MCA 2000 Amps HPCA Internal Resistance GC2 ABS Plastic - Flame Res. Rating UL94-HB MECHANICAL SPECIFICATIONS Group Size Terminal Type 11.14” Height (w/ terminal) 10.47” Height (case only) 7.13” Width 10.31” Length 76.1 lbs. Weight See reverse side M8 w/ TP08 Brass AP 283mm 266mm 181mm 262mm 34.5 kg Terminal Torque Case Type DISCHARGE TABLE (Constant Current) Time 20hr 10hr 8hr 5hr 3hr 2hr 1hr Amps 12.5 22.9 27.2 40.8 56.6 78.5 136 Rate 0.05CA 0.10CA 0.13CA 0.25CA 0.33CA 0.50CA 1.00CA DISCHARGE PROFILE (Constant Current) Battery bank spacing required, 12.5mm (1/2” inch) minimum Reserve @25 AMPS Reserve @75 AMPS 531 Minutes 135 Minutes 6-Volt Battery Temperature: 77°F (25°C) Terminal Voltage Discharge Time 6.5 6.0 5.5 5.0 4.5 4.0 1 2 2 5 5 10 10 Hours Minutes 20 20 60 250A 145A 40.8A 22.9A 12.5A 500A Terminal: M8 with TP08 Brass AP 191.5 262 266 181 80 262 283 20 20 21 17.2 19.1 16 17.9 21 25 25 M8 M8 45 40

Upload: others

Post on 27-Oct-2021

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GROUP GC2 - Inverters R US

DEEP

CYCL

E AGM

PREM

IUM

DEEP

CYC

LE SE

RIES

|ful

lriverb

attery

.com

DC250-6GROUP GC2

BATTERY & TERMINAL DIMENSIONS (All units shown in mm)

250 Amp Hours20 Hour Rate

CYCLING CAPACITY RESERVE CAPACITY

- All listed ratings are @ 100% SoC, T=77°F (25°C), 1.75VPC unless otherwise specified.- Specifications listed are for estimation purposes only. Battery performance can vary depending on application. Battery design subject to change.

(unit: mm)

6 Volt

1.6m Ω

ELECTRICAL SPECIFICATIONSNominal Voltage

275AHC100

250AHC20

229AHC10

204AHC5

960CCA

1160CA or MCA

2000 AmpsHPCA

Internal Resistance

GC2

ABS Plastic - Flame Res. Rating UL94-HB

MECHANICAL SPECIFICATIONSGroup Size

Terminal Type

11.14”Height (w/ terminal)

10.47”Height (case only)

7.13”Width

10.31”Length

76.1 lbs.Weight

See reverse sideM8 w/ TP08 Brass AP

283mm266mm181mm262mm34.5 kg

Terminal Torque

Case Type

DISCHARGE TABLE (Constant Current)Time20hr

10hr

8hr

5hr

3hr

2hr

1hr

Amps12.5

22.9

27.2

40.8

56.6

78.5

136

Rate0.05CA

0.10CA

0.13CA

0.25CA

0.33CA

0.50CA

1.00CA

DISCHARGE PROFILE (Constant Current)

Battery bank spacing required,12.5mm (1/2” inch) minimum

Reserve @25 AMPS Reserve @75 AMPS531 Minutes 135 Minutes

6-Volt Battery Temperature: 77°F (25°C)

Term

inal

Vol

tage

Discharge Time

6.5

6.0

5.5

5.0

4.5

4.0

1 2 25 510 10HoursMinutes

20 2060

250A 145A40.8A 22.9A 12.5A

500A

Terminal: M8 with TP08 Brass AP191.5262

266

18180

262 28

3

20 20

21

17.2

19.1

16

17.9

21

25 25

M8 M8

45

40

Page 2: GROUP GC2 - Inverters R US

Storage

Operation

Charge with TC

TEMPERATURE RANGE SPECIFICATIONS

Charge w/o TC*TC= Temperature Compensation

5°F to 122°F

RecommendedCondition

5°F to 104°F

5°F to 122°F

32°F to 104°F

-40°F to 160°F

Maximum

-40°F to 160°F

-40°F to 160°F

5°F to 122°F

-15°C to 50°C

Recommended

-15°C to 40°C

-15°C to 50°C

0°C to 40°C

-40°C to 71°C

Maximum

-40°C to 71°C

-40°C to 71°C

-15°C to 50°C

Bulk

Absorption

Float

CHARGE VOLTAGES

7.35V

6V

TC Factor: (-2mV/°F/cell) or (-4mV/°C/cell)

Charge Stage

Battery Voltages

7.35V

6.8V

14.7V

12V

14.7V

13.6V

29.4V

24V

29.4V

27.2V

58.8V

48V

58.8V

54.6V

TERMINAL TORQUE SPECS (applicable values are highlighted)

TEMPERATURE vs CAPACITY110%

100%

90%

80%

70%

60%

50%

40%

30%

20%

10%

0%-20 0

TEMPERATURE °F (°C)

CAPA

CITY

%

20 40 60 80 100 120(-29.9) (-17.8) (-6.7) (4.4) (15.6) (26.7) (37.8) (48.9)

STATE of CHARGE (SOC) vs OPEN CIRCUIT VOLTAGE (OCV)6.50

6.38

6.25

6.13

6.00

5.88

5.75

13.00

12.75

12.50

12.25

12.00

11.75

11.5010 20

State of Charge (SOC)

OCV

(6V

Batt

ery)

OCV (12V Battery)

30 40 50 60 70 90 10080

SELF DISCHARGE vs TIME/TEMPERATURE100%

90%

80%

70%

60%

50%

40%

30%

20%

10%

0%0 2 4 6 8 10 12 14 16 18 20 22 24STORAGE PERIOD (MONTHS) Note: “Boost Charge” required @ 75% SoC, Max 50% Soc

Stat

e of

Cha

rge

(SoC

)

104°F (40°C) 86°F (30°C) 77°F (25°C)

CYCLE LIFE vs DEPTH of DISCHARGE (DOD)100%

90%

80%

70%

60%

50%

40%

30%

20%

10%

0%

DO

D

0 500LIFE CYCLES (per BCI)

1000 1500 2000 2500 3000 40003500 4500 5000

*(Based on BCI Testing @ 2-hr Rate)

9001:2008 Quality Management System14001:2004 Environmental Management System18001:2007 Occupational Health & Safety Management System

DELIVERY APPROVED!

LAND, SEA& AIR

Fullriver batteries are sealed lead acid batteries made with Absorbed Glass Mat (AGM) technology. The electrolyte is absorbed into the fiberglass separator material rather than in a free-flowing liquid form. Fullriver batteries are non-spillable electric storage batteries. They are excepted from the requirements of DOT’s hazardous materials regulations, since they adhere to the requirements of code 49 CFR Section 173.159(D) - (CLASSIFIED APPROVED: DOT, CFR, HMR49, IATA, ICAO67, IMDG27)

CERTIFIED

M6, AP

50-70lbs-in

4.1-5.8ft-lbs

5.6-7.9Nm

M8

85-95lbs-in

7.1-7.9ft-lbs

9.6-10.7Nm

M10

115-141lbs-in

9.6-12ft-lbs

13-16Nm

M6M (Stud)

40-56lbs-in

3.3-4.6ft-lbs

4.5-6.3Nm

M8M (Stud)

58-75lbs-in

4.9-6.3ft-lbs

6.6-8.5Nm

M10M (Stud)

92-115lbs-in

7.7-9.6ft-lbs

10.4-13Nm

3/8” Stud

106-150lbs-in

8.9-12ft-lbs

12-16.9Nm

FR45

70-90lbs-in

5.8-7.4ft-lbs

7.9-10.1Nm

TP06 (AP)

40-56lbs-in

3.3-4.6ft-lbs

4.5-6.3Nm

TP08/TP68 (AP)

63-83lbs-in

50-70ft-lbs

7.1-9.4Nm