GRID CONNECTED SOLAR INVERTERS

Channel Partner and Techno-Commercial support in India from GreenTech Labs

www.greentech-labs.com

Page 2: GRID CONNECTED SOLAR INVERTERS Channel …greentech-labs.com/.../GreenTech_TBEA_GC_SolarInverters.pdfGRID CONNECTED SOLAR INVERTERS Channel Partner and Techno-Commercial support in

Grid ConnectedSolar Inverter 250 KW

FEATURES• Perfectsinewavecurrentoutput• Highconversionefficiency• Maximumpowerpointtracking(MPPT)>99%MPPTefficiency• Wideinputvoltagerange• Withouttransformerdesigning• AdvancedIGBTpowerdevices• Truecolortouchhuman-machineinterface• Easy-to-setmultilingualLCDdisplay• HigherreliabilityduetoPerfectprotectionfunction• Multiformcommunicationinterface• Modulardesign,easyinstallationandmaintenance• Adjustableprotectionandoperationparameters

Grid ConnectedSolar Inverter 500 KW

TBEASunOasisCo.,Ltd.isaprofessionalhi-techenterpriseengagedintheresearchandmanufactureofphotovoltaicproductsandsystemintegrationtechnology,co-investedbyTBEA,TsinghuaUniversity,andChinaEnergyConservationandEnvironmentalProtectionGroup,isfoundedin2000.whichisoneoftheearliesthi-techenterprisesengagedinsolarenergyresearchandexploration.

Page 3: GRID CONNECTED SOLAR INVERTERS Channel …greentech-labs.com/.../GreenTech_TBEA_GC_SolarInverters.pdfGRID CONNECTED SOLAR INVERTERS Channel Partner and Techno-Commercial support in

PARAMETERTBEA

GC-250KTL TBEA

GC-500KTLInput SideMPPTInputRange(VMPPTmin,r...VMPPTmax,r) 450-1000V 450-1000V

MPPTInputRange(VMPPTmin,f...VMPPTmax,f)atFullPower

450-820V 480-820V

AbsoluteMaximumInputVoltage(Vmax,abs) 1000V 1000V

NumberofIndependentMPPTInputs 1 1

MaximumCombinedInputCurrent(Idcmaxc) 600A 1200A

MaximumInputCurrentforEachModule(Idcmax,m) 600A 1200A

NumberofDCInputsPairs 2/16 2/16

DCConnectionsType 6xM10 10xM10

Output SideACGridConnection(Vacmin...Vacmax) Threephase Threephase

RatedPower(Pac,r) 250kW 500kW

RatedGridVoltage(Vac,r) 315V 315V

ACVoltageRange(Vacmin...Vacmax) 270-330V 270-330V

MaximumOutputCurrent(Iac,max) 590A 1180A

RatedFrequency(fr) 50/60Hz 50/60Hz

FrequencyRange(fmin...fmax) 48.5-52.5Hz 48.5-52.5Hz

NominalPowerFactor(Cosphiac,r <0.99 <0.99

TotalHarmonicDistortion <3% <3%

ACConnectionType 6xM10 9xM16

Input Protection ReversePolarityProtection Yes Yes

InputOverVoltageProtection Yes Yes

PhotovoltaicArrayIsolationControl Yes Yes

FuseSizeforEachInputPair 800A/1000V 1600A/1000V

Output ProtectionAnti-IslandingProtection Yes Yes

OutputOvervoltageProtection Yes Yes

ACCircuitBreaker T5 T7

NightTimeDisconnect Yes Yes

GRID CONNECTED SOLAR INVERTER: 250KW v/s 500KW

Page 4: GRID CONNECTED SOLAR INVERTERS Channel …greentech-labs.com/.../GreenTech_TBEA_GC_SolarInverters.pdfGRID CONNECTED SOLAR INVERTERS Channel Partner and Techno-Commercial support in

PARAMETERTBEA

GC-250KTL TBEA

GC-500KTLOperating Performance MaximumEfficiency(max)98.5%98.5% 98.20% 98.30%

WeightedEfficiency(EURO/CEC)98.2%/-98.2%/- 97.60% 97.70%

Stand-byConsumption/Night-timepowerloss<33W<66W

<50W <50W

AuxiliarySupply3x400Vac/N/PE3x400Vac/N/PE 3x400Vac/N/PE 3x400Vac/N/PE

AuxiliarySupplyConsumption<405W<810W <400W <400W

AuxiliarySupplyConsumptionwithoutCooling<100W<220W

<50W <50W

InverterSwitchingFrequency 2.4kHz 2.4kHz

CommunicationWiredLocalMonitoring-1xRS485(inc.) RS485_232 RS485_232

RemoteMonitoring-1xRS485(inc.) GPRS\Zigbee GPRS\Zigbee

StringCombiner1xRS485(inc.) RS485 RS485

UserInterface TFTLCD7” TFTLCD7”

PhysicalEnvironmentalProtection IP20 IP20

Cooling ForcedAir ForcedAir

Dimensions(H*W*D) 2200mm*1600mm*850mm

2200mm*2200mm*850mm

Weight 1400kg 2100kg

SafetyTransformerNoNo No No

Marking CE,TUV,CQC CE,TUV,CQC

SafetyandEMCStandard EN50178,EN61000-3-12,EN61000-6-2,EN61000-6-4,IEC62109-1

EN50178,EN61000-3-12,EN61000-6-2,EN61000-6-4,IEC62109-1

GridStandard IEC62109-1 IEC62109-1

GRID CONNECTED SOLAR INVERTER: 250KW v/s 500KW

Page 5: GRID CONNECTED SOLAR INVERTERS Channel …greentech-labs.com/.../GreenTech_TBEA_GC_SolarInverters.pdfGRID CONNECTED SOLAR INVERTERS Channel Partner and Techno-Commercial support in

100

99

98

97

96

95

94

93

92

0 25 75 100Pout/Prate[%]

n[%]

50

100

99

98

97

96

95

94

93

92

0 25 75 100Pout/Prate[%]

n[%]

50

EFFICIENCY CURVE: 500KW

CIRCUIT TOPOLOGY: 250KW and 500KW

EFFICIENCY CURVE: 250KW

Page 6: GRID CONNECTED SOLAR INVERTERS Channel …greentech-labs.com/.../GreenTech_TBEA_GC_SolarInverters.pdfGRID CONNECTED SOLAR INVERTERS Channel Partner and Techno-Commercial support in

GreenTech Labs - Channel partner for TBEA products

About UsGreenTechLabsLLP,incorporatedin2010,withitsregisteredofficeandR&DcentersituatedinBangalore,theITandTechnologyhubofIndia.GreenTechLabsisstrategicallylocatedclosetoanindustrialhubconsistingofmechanical,chemical,painting,coating,castingcompanies.GreenTechLabsLLP isdedicatedtodevelopingandmanufacturingnonconventionalenergyrelated products for both International & domestic customers. Our products includeSolarPowerOptimizerandMicro-Invertersforsolarpanels,SolarPhoto-voltaicModulesandData-Loggersforremoteenergymanagement.With a strong in-house R&D team both in hardware& software, GreenTech engineers areworking towards challenging new technologies and also constantly improvising existingproductsforreliabilityandefficiencies.

Greentech Labs LLP #140, 2nd Cross, 1st Phase, Reliable Residency, Harlur, HSR Layout,Bangalore 560 102, INDIA

Telephone: +91-80-22579011Handphone: +91 98920 10204E-mail: [email protected]

www.greentech-labs.com

The information provided in this document is subject to change without prior notice. GreenTech Labs LLP takes no responsibility for correctness of information provided.