green sustainable solar energy solutions

32
FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM GREEN SUSTAINABLE SOLAR ENERGY SOLUTIONS

Upload: others

Post on 20-Mar-2022

3 views

Category:

Documents


0 download

TRANSCRIPT

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

GREEN SUSTAINABLE SOLAR ENERGY SOLUTIONS

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

Speakers

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

Agenda

• NetHope Intro– Why is NetHope looking at Renewable Energy solutions?

• GSOL Energy Global

• General on Renewable Energy – System calculations– Do’s & Dont’s

• Field Solutions (with user cases)– Fixed Installations– Deployment Solutions– Containerized Solutions

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

GSOL Energy Global (GEG)

• Founded in 2010, established player specialized in advising on and providing quality solar solutions.

• Committed to remain at the forefront of the sustainable energy market within the humanitarian sector

• Offering 360°solution (from site survey to after sales support and maintenance)

• LTA holders for PV solutions

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

GEG ServicesProject Management Implementation Support Logistics

✓ Consultancy/Needs

Assessment

✓ Training ✓ Extended

Warranty

✓ Emergency Stock

✓ System design

(Multi-Standard

and Multi-Vendor

✓ Configuration ✓ Service Packages ✓ 48-hour global

delivery

✓ Product Lifecycle

Management &

Planning

✓ Installation

Supervision

✓ Local Maintenance ✓ Customized labels

and packaging

✓ Turnkey Solar

Power Solutions

✓ FAT/UAT ✓ Local Repair ✓ Consolidated

Shipments

✓ Assigned Project

Coordinator

✓ Commissioning ✓ Spare Parts ✓ Export Licenses

✓ Technical

Hotline/Online

Support

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

GEG – Projects around the world

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

General on Renewable Energy

• Renewable energy is goodfor the environment as youlimit your Co2 output– PV, Wind, Hydro– Often mixed with storage

systems

• When matched againstgenerators, Hybrid systems with PV and storage is alsothe cheapest solution if calculated right.

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

General on Renewable Energy

• When focus is on renewable energy it oftenalso generates focus on the actualconsumption and the limitation thereof.

• There is a renewable energy system for everypurpose. If you can define it properly you canimprove the overall TCO – even with backup generator.

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

System Calculations

• A battery driven energysystem is best designed to meet a defined load and energy profile.

• Inaccurate profile can makethe system

– Fail

– Unnecessarily expensiveBenghazi Pediatric Hospital, Libya

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

System Calculations

3 main factors:

• Power

– How much power (kW) is required to ensure the operation of all loads

• Energy

– How much energy (kWh) is required during a certainperiod – typically 24h

• Storage

– For how long time is it required for the system to operatewithout the need for external power sources

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

System Calculations

• Once the 3 main factors have been determined, you consider otherimportant system criteria– AC or DC Coupling

– Interaction with one or more external energysources

– Future expansion options

– Local conditions• Temperature

• Roof / Open space

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

Power

The amount of power needed is what is at maximum required to operate all load connected to the system.

Units Watt Watt total

Security light 10 50 500

Office light 20 30 600

Cooling 2 800 1600

Fans 8 30 240

IT equipment 1 2000 2000

Selfconsumption 1 200 200

TOTALS 5140

Overlay 20% 6168

Pmax 6168

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

Energy

The energy requirement is important to calculate the size of the PV plant.

Sometimes it is possible to measure the consumption and sometimes youhave to make a list of connected items and calculate the energy

Units Watt Watt total Hours in use (Day) Factor Wh Hours in use (Night) Factor Wh

Security light 10 50 500 2 100% 1000 12 100% 6000

Office light 20 30 600 10 100% 6000 0 100% 0

Cooling 2 800 1600 8 60% 7680 0 30% 0

Fans 8 30 240 10 100% 2400 0 50% 0

IT equipment 1 2000 2000 12 100% 24000 12 100% 24000

Selfconsumption 1 200 200 12 100% 2400 12 100% 2400

TOTALS 5140 43480 32400

Overlay 20% 6168 0% 43480 0% 32400

Pmax 6168

E24H 75880

E Day 43480

E Night 32400

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

Energy

The PV plant is meant to generate the energy needed for dayand night or a defined faction for systems with generally stable grid.

Pmax (W) 6.168 Pmax (VA) 8.867

E 24H (Wh) 75.880

E Day (Wh) 43480

E Night (Wh) 32400

E bat (Wh) 75.880 PV (kWp) 30,44

Power Factor 0,8 kVA-kW conversion

PV System Efficiency 0,7 0,7 when offgrid

Battery Efficiency 0,9

Battery Discharge lvl 0,5

Solar irridation (kWh/kWp) 1300

Solar irridation (kWh/m2) 3,5

Formula:=E 24H/1000*365/(Solar Irridation*System efficiency)

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

Energy

The used Solar irridation is a standard UN for worstproduction period. To get the proper value, you look at the total system and use a professional calculationprogram.

Pmax (W) 6.168 Pmax (VA) 8.867

E 24H (Wh) 75.880

E Day (Wh) 43480

E Night (Wh) 32400

E bat (Wh) 75.880 PV (kWp) 30,44

Power Factor 0,8 kVA-kW conversion

PV System Efficiency 0,7 0,7 when offgrid

Battery Efficiency 0,9

Battery Discharge lvl 0,5

Solar irridation (kWh/kWp) 1300

Solar irridation (kWh/m2) 3,5

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

Storage

Stored energy is used at time when PV and/or the external energy source is not available.

The tendencies is to consider:

- Nighttime only (Silent night)

- A few hours because grid is generally stable or a generator is automaticallystarting

- Several days (Vaccine or remote areas)

Pmax (W) 6.168 Pmax (VA) 8.867

E 24H (Wh) 75.880 BAT Ah @ 48V 3513

E Day (Wh) 43480 BAT AH @ 24V 7026

E Night (Wh) 32400 BAT AH @ 12V 14052

E bat (Wh) 75.880 PV (kWp) 30,44

PV System Efficiency 0,70,7 when offgrid

Battery Efficiency 0,9

Battery Discharge lvl 0,5

Formula:=E bat (Wh)/(Battery Efficiency (0,9)*Discharge level (0,5)*Bat voltage (48))

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

Storage TypeBattery Technologies:• AGM, GEL, Longlife 2V OPzV, 2V OPzS and LiOn batteries.

• AGM and GEL is used for small applications of no more than 15 kWh per day.

• 2V OPzV and 2V OPzS are designed for higher currents and in particular solar installations.

• Lithium is used primarily in applications with focus on low weight (mobile systems), limited space (Containers), UPS or where the client want the best TCO.

Battery On StockCycles at 50% d.o.d.

AGM Yes 600

GEL Yes 600

OPzV No 1000-3000

OPzS No 1000-3000

LiOn Yes 5000-10.000

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

Calculation sum up

• Know your power requirement (calculation or measure)– Look for the maximum simultaneous load

• Example: 6000W max load

• Know your energy requirement for a 24h period (calculationor measure). – Divide the found by 2,5-4 depending on local circumstance to get your

PV plant size in kWp• Example: Consumption is 60.000W

– PV requirement is minimum 60kW/4 = 15kWp (not regarding seasonal changes)

• Know your required storage in kW.– Divide the found by discharge level and efficiency (eg 0,5 and 0,9) to

get your storage.• Example: Night consumption is 20.000Wh

– Storage is 20kWh /(0,5 x 0,9) = 45 kWh.

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

Professional Calculations

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

Do’s and Dont’s

• Do’s:

– Make correct system calculations to increase the quality of your delivered and installed system.

– Instruct users that loweringconsumption significantlyimproves the system performance and TCO.

• Dont’s:

– Purchase a PV-Hybrid system as if it is a generator.• The energy that a generator

have 24 hours to generate, a PV system need to generate when daytime (or as in earlierexample, during 2,5-4 hours)

– Suddenly think that havingenergy means free access to energy. The system is designed for a purpose.

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

Field Solutions Examples

• Fixed Solar Power Systems

• Deployment Kits

– Pelicase

– Flightcase

• Containerized SolutionsHealth Facility in Red sea state - Sudan

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

Fixed Solar Power (PV) systems

• Completely customizable• Suitable for small and

large-scale power needs• On-grid, off-grid or hybrid

solutions• Ground- or roof mounted• Clean and renewable

energy solution (in line with SDG’s)

• Long-lasting, reliable and durable

• Cost-effective100 kWp on-grid system

UN compound Windhoek, Namibia

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

UN House Caicoli, Dili – Timor Leste

• Provision of a 300 kWp turnkey PV Solar System

• Installation of the PV system on different buildings

• Construction of steel frame canopies for placement of panels over car parking lots

• Installation and supervision/project management of the complete PV system/diesel generator hybrid solution and commissioning.

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

On-grid system in Zimbabwe

• 67 health facilitiesacross Zimbabwe

• 7kWp & 10kWp systems

• Battery backup

• Power critical loads

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

Deployment Solar Solution – Pelicase

• Renewable energy rapid deployment kits driven by flexible solar cells

• Dust, water and shock-proof

• Portable and durable in a variety of sizes (up to 150 amp hours from 1 or 2 batteries)

• Powerful enough to charge satellite, comms and laptops, these suitcases work well in remote locations, or for temporary power supply

• With customizable range of power levels and a selection of power source options, these products are a perfect on-the-spot, emergency energy solution.

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

Deployment Solar Solution – Flight case

• Larger-scale selection of self-contained renewable energy solutions

• Scalable size and driven by flexible solar cells or fixed solar panels

• Can provide from 1,200 to 15,000 amp hours

• Durable, “plug and play” solution fully water-& dust- and shock proof (reuse in multiple locations)

• Powerful enough to for smaller offices, comms rooms, IT and light supplies

• With customizable range of power levels and a selection of power source options, these products are a perfect on-the-spot, emergency energy solution

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

Containerized Power Solutions

• We design, build and implement containerized Solar PV Power Solutions

• Application in remote, rural areas with little or no public power connection

• Produce, use and store energy throughout the day and utilize stored power from battery storage system

• Cut down on diesel generator operations, expensive fuel costs and have silent hours when tapping into battery bank for evening and night power consumption

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

Plug and play solution

• Installation done prior to shipment

• Tested prior to dispatch to final destination

• Ready to connect onsite

• Training & Commissioning

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

Containerized Solution - KazakhstanIndependent Power for rural area of Kyzylorda

• Hybrid solution with 30 kVA system, wind turbine and generator

• 124 solar modules

• 48V/1325Ah battery bank

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

Projects Videos

• Please have a look at our GSOL Energy Global Youtube Channel

• https://www.youtube.com/channel/UCcgVMEG04f0-J6VudLIITlw

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

Q & As

FINLANDSVEJ 12 | 5700 SVENDBORG | DENMARK | TEL: +45 2227 2525 | WWW.GSOLENERGY.COM

Learn more on

www.gsolenergy.com@GSOLENERGY

GSOL Energy Global A/S

Or contact us directly:

Jesper Pedersen – [email protected] Ditlevsen – [email protected]

Duncan Drury – [email protected]