gree catalogo completo linha comercial 2012

36
COMMERCIAL AIR CONDITIONERS T1, 60Hz, R410A&R22 PRODUCTS CATALOGUE 2012 Distributor information Change For Life 2012 COMMERCIAL AIR CONDITIONERS T1, 60Hz, R410A&R22 Add:West Jinji Rd,Qianshan,Zhuhai,Guangdong,China 519070 Tel:(+86-756)8522218 Fax:(+86-756)8669426 Email:[email protected] Http://www.gree.com GREE ELECTRIC APPLIANCES,INC. OF ZHUHAI GC-1109-1 Specifications and appearance are subject to change without notice. Copyright Gree Electric Appliances,inc.of Zhuhai. All rights reserved. C

Upload: guilherme-gugelmin

Post on 17-Aug-2015

128 views

Category:

Services


20 download

TRANSCRIPT

Page 1: Gree   catalogo completo linha comercial 2012

COMMERCIAL AIR CONDITIONERST1, 60Hz, R410A&R22

PRODUCTS CATALOGUE 2012

Distributor information

Change For Life

2012C

OM

MER

CIA

L AIR

CO

ND

ITION

ERS

T1, 60Hz, R

410A&

R22

Add:West Jinji Rd,Qianshan,Zhuhai,Guangdong,China 519070Tel:(+86-756)8522218 Fax:(+86-756)8669426Email:[email protected] Http://www.gree.com

GREE ELECTRIC APPLIANCES,INC. OF ZHUHAI

GC-1109-1

Specifications and appearance are subject to change without notice.Copyright Gree Electric Appliances,inc.of Zhuhai. All rights reserved.C

Page 2: Gree   catalogo completo linha comercial 2012

GREE Electric Appliances, Inc. of Zhuhai, founded in 1991, is the world's

largest air conditioner enterprise integrating R&D, manufacturing,

marketing and services. With more than 150 million users over 100

countries and regions, Gree have topped No.1 in global sales market

since 2005. It has been ranked among the ‘Top 100 Chinese Listed

Companies’ by Fortune for 9 consecutive years.

COMPANY PROFILE

05

07

13

19

21

23

29

31

38

39

41

42

43

45

51

56

57

59

61

Unitary

U-match

Top Discharge Condensing Unit

Duct Split Unit

Rooftop Packaged Unit

Free Match

GMV

Inverter Series

Branching Joint

Chiller

Modular Air-cooled Scroll Chiller

Modular Air-cooled Screw Chiller

Terminal

Fan Coil Unit

Air Handling Unit

Diffuser

Specialized Air Conditioner

Marine Air Conditioner

Control System

CO

NTEN

TS

Page 3: Gree   catalogo completo linha comercial 2012

Golden fin condenserAnti-corrosive performance of golden fin is 3 times better than normal Fin.

Inner groove copperSpecial thickened inner groove copper tube enhances heat exchanging performance.

Built-in drain pumpThe drain pump can pump the condensation to a high level. It facilitates condensation draining from the indoor unit and makes the installation of indoor unit easier.

Washable filterFilters are easy to dismantle and install. You can use dirt collector or water to clear away the dust.

Quality motorQuality motor makes operation steady and in low noise.

Auxiliary electric heaterAuxiliary heater greatly improves heating capacity and saves energy.

High efficiencyThe air conditioner is designed to high energy efficiency and realizes power saving.

Intelligent defrostingMonitoring Intelligently to insure defrosting is performed if necessary. It improves heating efficiency and saves power.

Energy saving functionWhen this function is activated, the temperature setting is only in limited range, so that the energy is saved.

Comfortable sleeping modeThe setting temperature and the indoor noise can be adjusted to a more comfortable level when you set the “sleeping mode”.

Quiet functionUnit is ensured to operate with the lowest noise by ultra-low fan speed and auto adjustment according to system parameter.

Vertical swingAir discharge flaps can automatic move vertically for efficient air and temperature distribution throughout the room.

Horizontal swingAir discharge Louvre can automatic move horiizontally for efficient air and temperature distribution throughout the room.

Precise temperature controlThe temperature fluctuation can be controlled within plus and minus 0.5℃.

Turbo function To run with strong power and make you feel comfortable(cool or warm) quickly.

Fresh air supply ventilationThe unit can introduce a certain percentage of fresh air to satisfy the fresh air requirement.

Anti-cold functionThe indoor unit will not blow in the winter if the air is not worm enough

Some Parts

Memory functionUnit is able to remember the operations before power failure and automatically returns to those operations when power restored.

Compact designUnit is designed with smaller dimension, which is easy to install and transport, and saves the cost.

Easier maintainabilityThe unit is designed to be easier maintenance and component replacement.

Convenience

Modular structureHigh efficiency compressor presents reliable performance.

Low temperature heatingUnit is able to start and operate in normal when the ambient temperature is lower than -20℃ and heating capacity remains still.

Modular operatingA several units can operate together as modules, so that capacity output control is more precise, and also higher reliability.

Comprehensive protection The unit is designed with various of protection functions to ensure the reliability.

Wide voltage rangeThe unit can operate in wide range, greatly reducing the ambient temperature limitation.

Wide operation rangeUnit can operate in wide range, greatly reducing the ambient temperature limitation.

High ESPThe external static pressure range is higher, which ensures longer delivery distance for air to provide powerful cooling.

Multi fan speedThe fan can operate with multi speeds and satisfy different air flow volume requirement.

Versatility

Auto cleanAfter unit turn off , the indoor fan will keep running in low speed for a moment to dry the inner components and parts, in order to prevent mildew and keep users healthy.

Self-diagnosis Malfunction codes are shown on the display panel for fast and easy maintenance when problem occur.

Low voltage startupUnit is able to safely started when voltage below standard.

Reliability

24 hour timerUnit can be set to turn on or turn off at anytime in a day.(The timing interval is 5-minite.)

Weekly timerCan be set 0r start heating or cooling anytime on a daily or weekly basis.

℃/℉ switchUnder status of unit off, press MODE and “-” buttons simultaneity to switch ℃/℉.

Clock displayTime is shown on remote controller .

Child lockAvoid the child’s wrong operation on the remote controller.

Shield functionRemote control the indoor unit and shield the functions of wired controller which include ON/OFF, temp or mode setting, energy-saving function, etc.

Long-distance monitoringLong-distance monitoring enables the unit to be controlled and monitored from a long distance.

Centralized controlStarts, stops and regulates the air conditioner from a distance.

Key-card controlThe Key-card control function is especially designed for the hotel rooms, by removing the key-card the air conditioner can automatically switched to stand-by status.

Control

High Efficiency & Energy Saving

Comfortable & Healthy

COMMERCIALAIR CONDITIONERS

04COMMERCIAL AIR CONDITIONERS

03

Page 4: Gree   catalogo completo linha comercial 2012

U-MATCHTOP DISCHARGE CONDENSING UNITDUCT SPLIT UNITROOFTOP PACKAGED UNIT

UNITARY

COMMERCIALAIR CONDITIONERS

06COMMERCIAL AIR CONDITIONERS

05

UN

ITARY

Page 5: Gree   catalogo completo linha comercial 2012

U-Match

Double ambient temperature sensor design makes a precision temperature monitoring.

Low start-up current thanks to power delay control design.

Comprehensiveprotection

Easiermaintainability

Compactdesign

Qualitymotor

Flexibel air in/outlet and condensing water outlet direction according to different installation requirements.

Flexible design for installation, the air return can be either from bottom or rear, as well as the alternative drain water connections.

Optimized air duct design improves the performance and lower the noise.

Drain pump fitted as standard with increased lift of 1100mm.

Special low noise fan design.

Different swing angle design for cooling and heating mode for better comfort.

3-D air flue design.

Easy replacement of motor and fan blade thanks to clamp block propeller design.

Different swing angle design for cooling and heating mode for better comfort.

COMMERCIALAIR CONDITIONERS

08COMMERCIAL AIR CONDITIONERS

07

Cooling 95

Heating 47

75

43

80

70

67 70~125

60 19~75

Operation range (temperature)Outdoor condition

Nominal operating condition (temperature)Outdoor condition Indoor condition

DB (。F) WB (

。F) WB (

。F)WB (

。F)DB (

。F)

Item

Indoor Unit

Duct type Cassette type Floor ceiling type

GUCN18TD1AO GUCN24TD1AO GUCN30TD1AO GUCN36TD1AO GUCN36TF1AO GUCN36TH1AO

GUHN18TD1AO GUHN24TD1AO GUHN30TD1AO GUHN36TD1AO GUHN36TF1AO GUHN36TH1AO

GFH18D1BI GFH24D1BI GFH30D1BI

GKH18D1BI GKH24D1BI GKH30D1BI

GTH18D1BI GTH24D1BI GTH30D1BI GTH36D1BI

GFH42D1BI GFH48D1BI

GKH42D1BI GKH48D1BI

GTH42D1BI GTH48D1BI GTH60D1BI*

GFH36D1BI

Capacity Index (Btu/h) 36K 36K

Outdoor Unit

Indoor Unit

Duct

Cassette

Floor Ceiling

18K 24K 30K

GFH36D1BI

GUCN42TD1AO GUCN42TF1AO GUCN42TH1AO GUCN48TD1AO GUCN48TF1AO GUCN48TH1AO GUHN42TD1AO GUHN42TF1AO GUHN42TH1AO GUHN48TD1AO GUHN48TF1AO GUHN48TH1AO

Capacity Index (Btu/h)

Outdoor Unit

Indoor Unit

Duct

Cassette

Floor Ceiling

42K 60K48K

GFH60D1BI

GUCN60TF1A1O GUCN60TH1A1O GUHN60TF1A1O GUHN60TH1A1O

GUCN60TF1AO GUCN60TH1AO GUHN60TF1AO GUHN60TH1AO

It is a kind of split system that the outdoor unit can be freely connected to different types of indoor units according to various indoor decoration requirements.

Fixed Frequency Series

Units Line Up

* GUHN60TF1A1O and GUHN60TH1A1O can only match with duct type indoor unit.

UNITARY UN

ITARY

Page 6: Gree   catalogo completo linha comercial 2012

COMMERCIALAIR CONDITIONERS

10COMMERCIAL AIR CONDITIONERS

09

(W×D×H)

ESP

Outdoor unit

Panel

Indoor unit

Refrigerant charge volume

Current input

Power input

Power supply Ph/V/HzkWkWAAkg

CFM m3/h

PaPa

dB(A)

mmmm

kgmmmmkg

dB(A)mmmmkg

W/WBtu/h

WBtu/h

W

EER/COP*

Capacity

PackageCooling only

Heat pump

Cooling onlyHeat pump

Outline

PackageOutline

PackageOutline

RangeRated

ModelOutdoor unit

Indoor unit

Cooling

Heating*

Cooling

Heating*CoolingHeating*

Air flow volume

Sound pressure level (H/M/L)

Dimension

(W×D×H)Dimension

(W×D×H)Dimension

Net weight/Gross weight

Net weight/Gross weight

Sound pressure level

Net weight/Gross weight

Duct Cassette Floor ceiling Duct Cassette Floor ceiling

GFH18D1BI GKH18D1BI GTH18D1BI GFH24D1BI GKH24D1BI GTH24D1BI

GUHN24TD1AOGUHN18TD1AO GUCN24TD1AOGUCN18TD1AO

5000 5000 5200 7000 7000 700017000 17000 17700 23800 23800 238005500 5400 5900 7500 7100 750018800 18400 20000 25600 24200 25600

2.63/2.89 2.63/2.70 2.81/3.47 2.59/2.88 2.69/2.84 2.69/3.00

1.9 1.9 1.85 2.7 2.6 2.6 1.9 2.0 1.7 2.6 2.5 2.5 9.0 9.0 8.8 13.0 12.5 12.5 9.0 9.4 8.3 12.6 12.4 11.8 1.9 1.9 1.9 2.1 2.1 2.1

470/365/277 370/301/253 529/459/382 974/944/738 738/708/661 884/825/765800/620/470 630/512/430 900/780/650 1650/1600/1250 1250/1200/1120 1500/1400/1300

25 — — 25 — —0-40 — — 0-40 — —

46/45/44 49/47/45 42/38/34 49/47/45 49/47/45 50/48/451012×736×266 630×630×230 1220×700×225 1270×530×268 840×840×240 1420×700×2451123×798×323 851×681×325 1343×823×315 1348×597×283 963×963×325 1548×828×345

35/40 20/24 43/53 37/45 30/38 50/58— 650×650×40 — — 950×950×60 —— 670×730×102 — — 1040×1025×115 —— 4/7 — — 6.5/10 —

55/59997×431×740 1103×453×770912×378×690 1018×412×695

56

48/52

56

1/208-230/60 1/208-230/601/208-230/60 1/208-230/601/208-230/60 1/208-230/60

Connection pipe

inchinchm—Loading quantity 40'GP/40'HQ

Height/Length GasLiquidOuter

diameter

Max.distance100/108 108/118 89/97 88/99 74/83 63/70

15/20 15/30

kg 47/51 55/59

(W×D×H)

ESP

Connection pipe

Outdoor unit

Panel

Indoor unit

Refrigerant charge volume

Current input

Power input

Power supply Ph/V/HzkWkWAAkg

CFM m3/h

PaPa

dB(A)

mmmm

kgmmmmkg

dB(A)mmmmkgkg

inchinchm—

W/WBtu/h

WBtu/h

W

EER/COP*

Capacity

Loading quantity 40'GP/40'HQHeight/LengthGasLiquid

PackageOutline

PackageOutline

PackageOutline

RangeRated

ModelOutdoor unit

Indoor unit

Cooling

Heating*

Cooling

Heating*CoolingHeating*

Air flow volume

Sound pressure level (H/M/L)

Dimension

(W×D×H)Dimension

(W×D×H)Dimension

Net weight/Gross weight

Net weight/Gross weight

Sound pressure level

Net weight/Gross weight

Outer diameter

Max.distance

Cassette Floor Ceiling Cassette Floor CeilingGKH36D1B1I GTH36D1BI GKH36D1B1I GTH36D1BI

GUHN36TH1AOGUHN36TF1AO

GUCN36TH1AOGUCN36TF1AO

10500 10500 10500 10500

36000 36000 36000 36000

11000 11500 11000 1150037500 39200 37500 39200

2.69/2.82 2.62/3.11 2.69/2.82 2.62/3.11

3.9 4.0 3.9 4.0

3.9 3.7 3.9 3.7 13.0 13.5 6.5 6.6

13.0 12.6 6.5 6.2

972/907/830 1180/1032/914 972/907/830 1180/1032/9141650/1540/1410 2000/1750/1550 1650/1540/1410 2000/1750/1550

— — — —

— — — —52/50/47 55/52/47 52/50/47 55/52/47

840×840×320 1420×700×245 840×840×320 1420×700×245963×963×409 1548×828×345 963×963×409 1548×828×345

38/46 54/62 38/46 54/62

950×950×60 — 950×950×60 —

1040×1025×115 — 1040×1025×115 —6.5/10 — 6.5/10 —

60/66 58/70 60/66 58/70

3.6 3.6 3.6 3.6

3/220/60 3/220/60 3/380/60 3/380/60

Cooling onlyHeat pump

Cooling onlyHeat pump

(W×D×H)

ESP

Connection pipe

Outdoor unit

Panel

Indoor unit

Refrigerant charge volume

Current input

Power input

Power supply Ph/V/HzkWkWAAkg

CFM m3/h

PaPa

dB(A)

mmmm

kgmmmmkg

dB(A)mmmm

kgkg

inchinchm—

W/WBtu/h

WBtu/h

W

EER/COP*

Capacity

Loading quantity 40'GP/40'HQHeight/LengthGasLiquid

PackageOutline

PackageOutline

PackageOutline

RangeRated

ModelIndoor unit

Cooling

Heating*

Cooling

Heating*CoolingHeating*

Air flow volume

Sound pressure level (H/M/L)

Dimension

(W×D×H)Dimension

(W×D×H)Dimension

Net weight/Gross weight

Net weight/Gross weight

Sound pressure level

Net weight/Gross weight

Outer diameter

Max.distance

Duct Floor ceiling Duct Floor ceilingGFH42D1BI GTH42D1BI

CassetteGKH42D1BI GFH42D1BI

CassetteGKH42D1BI GTH42D1BI

GUHN42TF1AOGUHN42TD1AO

GUCN42TF1AOGUCN42TD1AO

12300420001400048000

2.43/2.591/208-230/60

5.075.4

25.5 27.5 4.5

1410/1165/9702400/1980/1650

370-37

55/51/481226×775×2901338×837×305

57/64———

12000410001400048000

2.60/2.651/208-230/60

4.625.2823.0 25.0 4.5

970/900/8301650/1540/1410

——

52/50/47840×840×320963×963×409

38/46950×950×60

1040×1025×1156.5/10

611107×440×11001158×483×1235

109/122109/122

1/2 3/430/50

12300420001400048000

2.43/2.643/220/60

5.075.3

15.5 17.1 4.5

1410/1165/9702400/1980/1650

370-37

55/51/481226×775×2901338×837×305

57/64———

12300420001400048000

2.62/2.861/208-230/60

4.7 4.9

23.5 22.5 4.5

1090/960/8301850/1640/1420

——

55/52/471420×700×2451548×828×345

57/65———

12000410001400048000

2.61/2.853/220/60

4.6 4.9114.5 14.0 4.5

970/900/8301650/1540/1410

——

52/50/47840×840×320963×963×409

38/46950×950×60

1040×1025×1156.5/10

611107×440×11001158×483×1235

109/122109/122

1/2 3/430/50

12300420001400048000

2.62/2.863/220/60

4.7 4.9 14.5 14.5 4.5

1090/960/8301850/1640/1420

——

55/52/471420×700×2451548×828×345

57/65———

44/52 44/59 40/50 44/5240/5044/59

Outdoor unitCooling onlyHeat pump

Cooling onlyHeat pump

(W×D×H)

ESP

Connection pipe

Outdoor unit

Panel

Indoor unit

Refrigerant charge volume

Current input

Power input

Power supply Ph/V/HzkWkWAAkg

CFM m3/h

PaPa

dB(A)

mmmm

kgmmmmkg

dB(A)mmmmkg

inchinchm

W/WBtu/h

WBtu/h

W

EER/COP*

Capacity

Loading quantity 40'GP/40'HQ

Height/LengthGasLiquid

PackageOutline

PackageOutline

PackageOutline

RangeRated

ModelIndoor unit

Cooling

Heating*

Cooling

Heating*CoolingHeating*

Air flow volume

Sound pressure level (H/M/L)

Dimension

(W×D×H)Dimension

(W×D×H)Dimension

Net weight/Gross weight

Net weight/Gross weight

Sound pressure level

Net weight/Gross weight

Outer diameter

Max.distance

Duct CassetteGUHN30TD1AOGUCN30TD1AO

Floor ceiling Duct CassetteGUHN36TD1AOGUCN36TD1AO

Floor ceilingGFH30D1BI GKH30D1BI GTH30D1BI GFH36D1BI GKH36D1BI GTH36D1BI

8500 8500 8800 10000 10000 10000

29000 29000 30000 34100 34100 34100

9300 9300 9300 10700 10300 10700

31700 31700 31700 36500 35100 36500

2.46/2.74 2.54/2.82 2.63/2.82 2.50/3.06 2.86/2.86 2.78/3.34

3.45 3.35 3.35 4.0 3.5 3.6

3.4 3.3 3.3 3.5 3.6 3.2

16.5 16.0 16.0 19.0 16.8 17.0

16.0 15.5 15.8 16.0 17.2 15.0

974/944/738 738/708/661 884/825/765 1473/1001/766 972/907/830 1180/1032/914

1650/1600/1250 1250/1200/1120 1500/1400/1300 2500/1700/1300 1650/1540/1410 2000/1750/1550

37 — — 37 — —

0-50 0 50— — — —49/47/45 49/47/45 50/48/45 55/51/48 52/50/47 55/52/47

1270×530×268 840×840×240 1420×700×245 1226×775×290 840×840×320 1420×700×2451348×597×283 963×963×325 1548×828×345 1338×837×305 963×963×409 1548×828×345

37/45 30/38 50/58 57/64 38/46 54/62

— 950×950×60 — — 950×950×60 —

— 1040×1025×115 — — 1040×1025×115 —— 6.5/10 — — 6.5/10 —

74/83 63/76 56/70 58/71 60/68 56/7015/30 30/50

68/76 68/761083×488×855 1083×488×855980×427×790 980×427×790

58 58

2.9 2.9 2.9 3.4 3.4 3.4

1/208-230/60 1/208-230/601/208-230/601/208-230/60 1/208-230/601/208-230/60

kg 68/76 68/76

Cooling only

Heat pump

Cooling onlyHeat pump

Outdoor unit

* Only available for heat pump model. * Only available for heat pump model.

1/2

3/8 3/8

5/8

3/4 1/2

5/8 3/8

30/50

87/951103×453×10001018×412×840

60

89/96

3/4

1/2

30/50

87/951103×453×10001018×412×840

60

89/96

3/4

1/2

UNITARY UN

ITARY

Page 7: Gree   catalogo completo linha comercial 2012

COMMERCIALAIR CONDITIONERS

12COMMERCIAL AIR CONDITIONERS

11

(W×D×H)

ESP

Connection pipe

Outdoor unit

Panel

Indoor unit

Refrigerant charge volume

Current input

Power input

Power supply Ph/V/HzkWkWAAkg

CFM m3/h

PaPa

dB(A)

mmmm

kgmmmmkg

dB(A)mmmmkgkg

inchinchm—

W/WBtu/h

WBtu/h

W

EER/COP*

Capacity

Loading quantity 40'GP/40'HQHeight/LengthGasLiquid

PackageOutline

PackageOutline

PackageOutline

RangeRated

ModelIndoor unit

Cooling

Heating*

Cooling

Heating*CoolingHeating*

Air flow volume

Sound pressure level (H/M/L)

Dimension

(W×D×H)Dimension

(W×D×H)Dimension

Net weight/Gross weight

Net weight/Gross weight

Sound pressure level

Net weight/Gross weight

Outer diameter

Max.distance

Duct Floor ceiling Duct Floor ceilingGFH42D1BI GTH42D1BI

CassetteGKH42D1BI GFH48D1BI

CassetteGKH48D1BI GTH48D1BI

GUHN48TD1AOGUHN42TH1AO

GUCN48TD1AOGUCN42TH1AO

12300420001400048000

2.43/2.663/380/60

5.075.279.0 9.2 4.6

1410/1165/9702400/1980/1650

370-37

55/51/481226×775×2901338×837×305

57/64———

12000410001400048000

2.61/2.853/380/60

4.6 4.918.0 8.0 4.6

970/900/8301650/1540/1410

——

52/50/47840×840×320963×963×409

38/46950×950×60

1040×1025×1156.5/10

611107×440×11001158×483×1235

109/122109/122

1/2 3/4

30/50

13200450001600054600

2.17/2.581/208-230/60

6.076.2 29.0 28.5 4.6

1410/1165/9702400/1980/1650

50 0-50

55/51/481226×775×2901338×837×305

57/64———

12300420001400048000

2.62/2.863/380/60

4.7 4.9 8.0 8.0 4.6

1090/960/8301850/1640/1420

——

55/52/471420×700×2451548×828×345

57/65———

13200450001520052000

2.40/2.601/208-230/60

5.5 5.85 26.5 27.0 4.6

970/900/8301650/1540/1410

——

52/50/47840×840×320963×963×409

38/46950×950×60

1040×1025×1156.5/10

611107×440×11001158×483×1235

109/122109/122

1/2 3/4

30/50

14000480001600054600

2.50/2.801/208-230/60

5.6 5.7

27.5 28.5 4.6

1470/1210/9902500/2060/1690

——

58/56/531700×700×2451828×828×345

65/73———

44/52 44/59 40/50 44/4840/5044/59

Outdoor unitCooling onlyHeat pump

Cooling onlyHeat pump

ESP

Connection pipe

Outdoor unit

Panel

Indoor unit

Refrigerant charge volume

Current input

Power input

Power supply Ph/V/HzkWkWAAkg

CFM m3/h

PaPa

dB(A)

mmmm

kgmmmmkg

dB(A)mmmmkgkg

inchinchm—

W/WBtu/h

WBtu/h

W

EER/COP*

Capacity

Loading quantity 40'GP/40'HQHeight/LengthGasLiquid

PackageOutline

PackageOutline

PackageOutline

RangeRated

ModelIndoor unit

Cooling

Heating*

Cooling

Heating*CoolingHeating*

Air flow volume

Sound pressure level (H/M/L)

Dimension(W×D×H)

Dimension(W×D×H)

Dimension(W×D×H)

Net weight/Gross weight

Net weight/Gross weight

Sound pressure level

Net weight/Gross weight

Outer diameter

Max.distance

Floor ceiling Duct Floor ceiling Floor ceilingGTH60D1BI GFH60D1BI

Floor ceilingGTH60D1BI GTH60D1BI

DuctGFH60D1BI GTH60D1BI

GUHN60TF1AO

GUCN60TH1A1OGUCN60TF1AO

GUHN60TH1AO

GUCN60TH1AO

GUHN60TF1A1O* GUHN60TH1A1O*

GUCN60TF1A1O

17000580001820062000

2.66/2.843/220/60

6.4 6.4

18.0 18.0 6.1

1470/-/-2500/-/-

——

58/56/531700×700×2451828×828×345

65/73———66

750×750×851773×773×1005

116/124113/128

1/2 3/430/5040/48

17000580001820062000

2.66/2.843/220/60

6.4 6.4

18.0 18.0 6.1

1470/-/-2500/-/-

——

58/56/531700×700×2451828×828×345

65/73———66

750×750×851773×773×1005

116/124113/128

1/2 3/430/5040/48

17000580001820062000

2.66/2.843/380/60

6.4 6.4

10.0 10.0 6.1

1470/-/-2500/-/-

——

58/56/531700×700×2451828×828×345

65/73———66

750×750×851773×773×1005

110/128115/130

1/2 3/430/5040/48

16400560002000068000

2.48/3.511/208-230/60

6.6 5.7

20.0 18.0 5.6

2120/1880/16503600/3200/2800

500-200

60/58/551463×799×3891543×883×470

88/111———66

1255×460×13501303×503×1490

134/151138/155 1/2 3/430/5029/31

17000580001820062000

2.66/2.843/220/60

6.4 6.4 18.0 18.0 6.1

1470/-/-2500/-/-

——

58/56/531700×700×2451828×828×345

65/73———66

750×750×851773×773×1005

116/124113/128

1/2 3/430/5040/48

16400560002000068000

2.48/3.511/208-230/60

6.6 5.7 20.0 18.0 5.6

2120/1880/16503600/3200/2800

500-200

60/58/551463×799×3891543×883×470

88/111———66

1255×460×13501303×503×1490

134/151138/155 1/2 3/430/5029/31

Outdoor unitCooling only

Heat pump

Cooling onlyHeat pump

(W×D×H)

ESP

Connection pipe

Outdoor unit

Panel

Indoor unit

Refrigerant charge volume

Current input

Power input

Power supply Ph/V/HzkWkWAAkg

CFM m3/h

PaPa

dB(A)

mmmm

kgmmmmkg

dB(A)mmmmkgkg

inchinchm—

W/WBtu/h

WBtu/h

W

EER/COP*

Capacity

Loading quantity 40'GP/40'HQHeight/LengthGasLiquid

PackageOutline

PackageOutline

PackageOutline

RangeRated

ModelIndoor unit

Cooling

Heating*

Cooling

Heating*CoolingHeating*

Air flow volume

Sound pressure level (H/M/L)

Dimension

(W×D×H)Dimension

(W×D×H)Dimension

Net weight/Gross weight

Net weight/Gross weight

Sound pressure level

Net weight/Gross weight

Outer diameter

Max.distance

Duct Floor ceiling Duct Floor ceilingGFH48D1BI GTH48D1BI

CassetteGKH48D1BI GFH48D1BI

CassetteGKH48D1BI GTH48D1BI

GUHN48TH1AOGUHN48TF1AO

GUCN48TH1AOGUCN48TF1AO

13200450001600054600

2.28/2.713/220/60

5.8 5.9 18.5 19.0 4.4

1410/1165/9702400/1980/1650

50 0-50

55/51/481226×775×2901338×837×305

57/64———

13200450001520052000

2.40/2.603/220/60

5.5 5.8517.0 18.5 4.4

970/900/8301650/1540/1410

——

52/50/47840×840×320963×963×409

38/46950×950×60

1040×1025×1156.5/10

611107×440×11001158×483×1235

109/122109/122

1/2 3/4

30/50

13200450001600054600

2.28/2.713/380/60

5.8 5.9 10.0 10.5 4.4

1410/1165/9702400/1980/1650

50 0-50

55/51/481226×775×2901338×837×305

57/64———

14000480001600054600

2.60/2.803/220/60

5.385.7 17.8 18.0 4.4

1470/1210/9902500/2060/1690

——

58/56/531700×700×2451828×828×345

65/73———

13200450001520052000

2.40/2.603/380/60

5.5 5.859.5 10.5 4.4

970/900/8301650/1540/1410

——

52/50/47840×840×320963×963×409

38/46950×950×60

1040×1025×1156.5/10

611107×440×11001158×483×1235

109/122109/122

1/2 3/4

30/50

14000480001600054600

2.60/2.803/380/60

5.385.7 9.8

10.0 4.4

1470/1210/9902500/2060/1690

——

58/56/531700×700×2451828×828×345

65/73———

44/48 44/59 40/50 44/4840/5044/59

Outdoor unitCooling only

Heat pump

Cooling onlyHeat pump

* Only available for heat pump model.

* Only available for heat pump model. GUHN60TF1A1O and GUHN60TH1A1O can only match with duct type indoor unit.

UNITARY UN

ITARY

Page 8: Gree   catalogo completo linha comercial 2012

Top Discharge Condensing Unit

Evolution SeriesIt is a kind of split system that adopt DC inverter compressor and with a high SEER of 22 which is far above the ENERGY STAR standard.

Excellent part load performance and precise temperature maintenance thanks to DC inverter compressor.

Power supply startup delay design, lower the unit starting current.

Outdoor unit base design, to meet various installation requirements without additional support needed.

Micro channel heat exchanger (MCHX) makes a higher efficiency and lighter weight.

No signal interfering thanks to strong and weak current separate wiring.

COMMERCIALAIR CONDITIONERS

14COMMERCIAL AIR CONDITIONERS

13

Inner groovecopper

Compactdesign

Easiermaintainability

Comprehensiveprotection

95 75 80 67

Operating range (temperature)

DB (℉) WB (℉)DB (℉) WB (℉) DB (℉)

Cooling 67~115

Item

Nominal operating condition (temperature)

Outdoor condition Indoor condition Outdoor condition

Model HW18018PNa-D HW18024PNa-D HW18030PNa-D HW18036PNa-D HW18042PNa-DCooling Btu/h 18000 23000 30000 35000 41000

Ph/V/Hz 1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60Cooling kW 1.54 1.96 2.38 2.85 3.7

Cooling A 11.1 14.5 16.6 18.7 24.1CFM 1764 1764 2650 2650 3530

m3/h 3000 3000 4500 4500 6000

dB(A) 57 62 62 63 65Outline mm 610×610×620 610×610×620 710×710×735Package mm 651×651×655 651×651×655 773×773×755

710×710×735773×773×755

710×710×850773×773×885

kg 63/68 64/68 80/85 81/86 91/96Liquid inch

Gas inch

40'GP — 162 162 135 135 9040'HQ — 216 216 135 135 135

Loading quantity

Power supply

Cooling onlyCapacity

Connection pipe diameter

Air flow volume

Power input

Rated current

Sound pressure level

Dimension(W×D×H)

Net weight/Gross weight3/85/8

3/85/8

3/83/4

3/83/4

3/87/8

Outdoor Unit (Up to 22 SEER)

A Coil

532×540×550

572×590×605

532×540×550 532×540×700

572×590×605 572×607×750

532×540×700

572×607×750

621×540×700

656×622×750

240 240 228 228 162

320 320 228 228 162

Model CACR1301824G CACR1301824G CACR1303036H CACR1303036H CACR1304248HOutline mm

Package mm

Liquid inch

Gas inch

40'GP —

40'HQ —

Dimension(W×D×H)

Connection pipe diameter

Loading quantity

3/8

5/8

3/8

5/8

3/8

5/8

3/8

3/4

3/8

7/8

Air Handler

Model HNF18018-D HNF18024-D HNF18030-D HNF18036-D HNF18042-DBtu/h 18000 23000 30000 35000 41000

Ph/V/Hz 1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60AC AC AC DC DC

kW 0.12 0.13 0.26 0.21 0.238A 0.7 0.82 1.45 1.01 1.12

CFM 610 750 1050 1147 1235

m3/h 1030 1270 1780 1950 2100

Pa 25 25 37 37 37

dB(A) 43 44 47 48 52

Outline mm 532×540×1105

Package mm 572×590×1160532×540×1105 532×540×1224572×590×1160 572×607×1280

532×540×1224572×607×1280

621×540×1224656×622×1280

kg 55 55 66 66 77kg 59 59 70 70 81

Liquid inch

Gas inch

40'GP —

154 154 112 112 8140'HQ — 154 154 152 152 108

Cooling capacityPower supply

Air flow volume

ESPSound pressure level

Dimension(W×D×H)

Loading quantity

Gross weight

Motor typePower input

Connection pipe diameter

Rated current

Net weight

3/85/8

3/85/8

3/85/8

3/83/4

3/87/8

Self-diagnosis

Wired remote controllerZ1A001A

UNITARY UN

ITARY

Page 9: Gree   catalogo completo linha comercial 2012

Top Discharge Condensing Unit

Fix Frequency SeriesIt is a kind of split system that is widely used in residential or commercial building and could be sold by set or separately.

Outdoor unit base design, to meet various installation requirements without additional support needed.

Micro channel heat exchanger (MCHX) makes a higher efficiency and lighter weight.(N/A for heat pump unit)

Three kinds indoor unit installation methods, to meet different construction requirements.

No signal interfering thanks to strong and weak current separate wiring.

COMMERCIALAIR CONDITIONERS

16COMMERCIAL AIR CONDITIONERS

15

Inner groovecopper

Easiermaintainability

Self-diagnosis Compactdesign

95 75 80 67 67~115

47 43 70 60

Operating range (temperature)

DB (℉) WB (℉)DB (℉) WB (℉) DB (℉)

Cooling

Heating 17~75

Item

Nominal operating condition (temperature)

Outdoor condition Indoor condition Outdoor condition

14 SEER

14 SEER

Model Cooling only HW14018Na-D HW14024Na-D HW14030Na-D HW14036Na-D HW14042Na-D HW14048Na-D HW14060Na-DW 5275 7030 8790 9960 12000 13400 16000

Btu/h 18000 24000 30000 34000 41000 46000 56000Ph/V/Hz

kW 1.54 1.98 2.55 2.91 3.50 3.80 5.00 A 9.1 11.6 14.6 19.2 24.3 27.4 30.0

CFM 1764 2650 2650 3530 3530 3530 4410m3/h 3000 4500 4500 6000 6000 6000 7500dB(A) 58 57 62 62 63 64 66

Outline mm 610×610×620Package mm 651×651×655

710×710×735773×773×755

710×710×735773×773×755

710×710×735773×773×755

710×710×735773×773×755

710×710×850773×773×885

750×750×850773×773×990

kg 50 63 65 77 87 88 97kg 55 68 70 83 93 95 113

Liquid inchGas inch40'GP — 162 135 135 135 135 90 9040'HQ — 216 135 135 135 135 135 90

Rated current

Cooling capacity

Power input

Net weight

Loading quantity

Power supply 1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60

Connection pipe diameter

Dimension(W×D×H)

Sound pressure level

Air flow volume

Gross weight

3/85/8

3/85/8

3/83/4

3/83/4

3/87/8

1/29/8

1/29/8

Model Heat pump HWR14018Na-D HWR14024Na-D HWR14030Na-D HWR14036Na-D HWR14042Na-D HWR14048Na-D HWR14060Na-DW 5180 6680 8790 9960 11870 13100 15500

Btu/h 17700 22800 30000 34000 40500 45000 53000W 4510 5862 7620 9085 10250 12000 14360

Btu/h 15400 20000 26000 31000 35000 41000 49000Ph/V/Hz

Cooling kW 1.54 1.96 2.38 2.85 3.50 4.10 5.36Heating kW 1.35 1.72 2.15 2.70 3.05 3.40 4.85Cooling A 11.1 14.5 16.6 18.7 24.1 26.3 32.4Heating A 10.8 13 16.2 17 22.8 23 30.5

CFM 1764 1764 2650 2650 3530 3530 4410m3/h 3000 3000 4500 4500 6000 6000 7500dB(A) 57 62 62 63 65 65 66

Outline mm 610×610×620Package mm 651×651×655

610×610×620651×651×655

710×710×735773×773×755

710×710×735773×773×755

710×710×735773×773×755

710×710×850773×773×885

750×750×850773×773×990

kg 63 64 80 81 91 100 107kg 68 68 85 86 96 104 121

Liquid inchGas inch40'GP — 162 162 135 135 135 90 9040'HQ — 216 216 135 135 135 135 90

CapacityHeating

Connection pipe diameter

Sound pressure level

Gross weight

Cooling

Air flow volume

Loading quantity

Power supply 1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60

Power input

Rated current

Net weight

Dimension(W×D×H)

3/85/8

3/85/8

3/83/4

3/83/4

3/87/8

1/29/8

1/29/8

13 SEER

Model HW18-D HW24-D HW30-D HW36-D HW42-D HW48-D HW60-DW 5275 7033 8792 10550 12309 14068 17585

Btu/h 18000 24000 30000 36000 42000 48000 60000Ph/V/Hz

kW 1.34 1.97 2.50 2.90 3.25 4.05 5.12A 6.3 8.7 11.9 14.5 16.1 18.5 32.3

CFM 1764 1764 2650 2650 2650 3530 4410m3/h 3000 3000 4500 4500 4500 6000 7500dB(A) 59 62 62 63 63 64 68

Outline mm 610×610×604Package mm 648×648×634

610×610×604648×648×634

710×710×718 710×710×718 710×710×718770×770×740 770×770×750 770×770×750

710×710×832770×770×852

710×710×832770×770×990

kg 54/56 55/57 75/77 83/85 83/85 85/87 108/113Liquid inchGas inch40'GP — 162 162 135 135 135 90 9040'HQ — 216 216 135 135 135 135 90

Power supplyPower inputRated current

Air flow volume

Sound pressure level

Dimension(W×D×H)

1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60

Cooling only

Loading quantity

Net weight /Gross weight

Connection pipe diameter

Cooling capacity

3/85/8

3/85/8

3/83/4

3/83/4

3/83/4

1/29/8

1/29/8

℃/℉ Switch

Model

(W×D×H)

HWR18-D HWR24-D HWR30-D HWR36-D HWR42-D HWR48-D HWR60-D

W 5275 7033 8790 10548 12309 14068 17585

Btu/h 18000 24000 30000 36000 42000 48000 60000

W 4820 5860 8057 9376 11134 12309 14650

Btu/h 16500 20000 27500 32000 38000 42000 50000

Ph/V/HzCooling kW 1.54 2.12 2.58 3.17 3.87 4.42 5.35Heating kW 1.40 1.79 2.52 2.97 3.42 3.86 4.75Cooling A 9.2 13 16.3 19.4 26.4 26.8 31.6Heating A 9.9 11.4 15.6 18.9 18.8 23.8 29.8

dB(A) 60 62 64 65 65 64 68Outline mm 610×610×604Package mm 648×648×634

610×610×604648×648×634

710×710×718770×770×750

710×710×718 710×710×718770×770×750 770×770×750

710×710×832770×770×852

750×750×832770×770×990

kg 61/63 67/69 83/86 85/88 87/90 98/102 115/120

Liquid inchGas inch40'GP — 162 162 135 135 135 90 90

40'HQ — 216 216 135 135 135 135 90

Rated current

CapacityCooling

Heating

Connection pipe diameter

Loading quantity

Air flow volume

Sound pressure level

Dimension

Net weight/Gross weight

Power supply 1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60

Power input

Heat pump

3/85/8

3/85/8

3/83/4

3/83/4

3/83/4

1/29/8

1/29/8

1764 1764 2650 2650 2650 3530 4410CFM 3000 3000 4500 4500 4500 6000 7500m3/h

UNITARY UN

ITARY

Page 10: Gree   catalogo completo linha comercial 2012

COMMERCIALAIR CONDITIONERS

18COMMERCIAL AIR CONDITIONERS

17

Fan Coil

Model HNDF18-D HNDF24-D HNDF30-D HNDF36-DW 5275 7033 8792 10550

Btu/h 18000 24000 30000 36000Ph/V/Hz 1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60

W 1500 1960 2450 3000A 10.23 12.64 15.00 18.00

CFM 647 691 883 1000m3/h 1100 1174 1500 1700dB(A) 52 52 52 53

Outline mmPackage mm

1034×245×5201093×260×568

1034×245×5201093×260×568

1334×245×5201393×260×568

1334×245×5201393×260×568

kg 21/26 21/26 29/36 29/36Liquid mm 9.52 9.52 9.52 9.52Gas mm 16 16 19 1940'GP — 336 336 264 26440'HQ — 378 378 297 297

Air flow volume

Dimension (W×D×H)

Net weight/Gross weight

Connection pipe diameter

Rated current

Sound pressure level

Cooling only

Capacity

Power supperPower input

Loading quantity

Air Handler

Model HNF13018-D HNF13024-D HNF13030-D HNF13036-D HNF1304260-D HNF1404260-DW 5275 7030 8790 10550 12309-17585 12309-17585

Btu/h 18000 24000 30000 36000 42000-60000 42000-60000Ph/V/Hz

kW 1.542 1.98 2.55 2.91 3.5 5A 9.1 11.6 14.6 19.2 24.3 30

AC AC AC AC DC DCCFM 610 750 1050 1150 1250-1650 1250-1650m3/h 1030 1270 1780 1955 2125-2805 2125-2805

Rate Pa 25 25 37 37 37 50Range Pa 0-80 0-80 0-120 0-120 0-160 0-160

dB(A) 43 44 47 48 52-62 52-62Outline mm 532×540×1105Package mm 571×597×1160

532×540×1105 532×540×1224571×597×1160 571×607×1280

532×540×1224571×607×1280

621×540×1224656×621×1280

621×675×1224663×758×1295

kg 55/59 55/59 66/70 66/70 77/81 90/98Liquid inchGas inch40'GP —

154 154 112 112 81 6640'HQ — 154 154 152 152 108 102

Loading quantity

Dimension(W×D×H)

Air flow volume

Sound pressure level

ESP

Net weight/Gross weight

Connection pipe diameter

Motor type

1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/601/208-230/601/208-230/60

Cooling capacity

Power supplyPower inputRated current

3/8

5/83/85/8

3/83/4

3/83/4

3/87/8

1/29/8

10 SEER / 60HzModel HW18M/A-D HW24M/A-D HW30M/A-D HW30M/A-D HW36M-F HW42M-F

W 5275 7033 8792 8792 10550 12309Btu/h 18000 24000 30000 30000 36000 42000

Ph/V/Hz 1/208-230/60 1/208-230/60 1/208-230/60 230 3/208-230/60 3/208-230/60

W 1509 2264 3355 2958 4200 4400A 10.30 13.73 19.10 19.25 17.95 18.67

CFM 1764 1764 2650 2650 2650 2650m3/h 3000 3000 4500 4500 4500 4500

dB(A) 59 67 63 65 63 63Outline mm 546×546×604Package mm 573×573×649

546×546×604573×573×649

546×546×718573×573×763

546×546×718573×573×763

610×610×830651×651×865

710×710×718773×773×755

kg 44/46 46/48 57/60 57/60 75/79 70/75Liquid inch

Gas inch

40’GP — 252 252 252 252 108 135

40’HQ — 336 336 336 336 162 135

Cooling only

Capacity

Power supplyPower inputRated current

Air flow volume

Sound pressure level

Dimension(W×D×H)

Loading quantity

Net weight/Gross weight

Connection pipe diameter

3/85/8

3/85/8

3/83/4

3/83/4

3/83/4

3/87/8

ModelW

Btu/hPh/V/Hz

WA

CFMm3/h

dB(A) Outline mm

Package mm

kgLiquid inch

Gas inch

40’GP —

40’HQ —

Cooling only

Capacity

Power supplyPower inputRated current

Air flow volume

Sound pressure level

Dimension(W×D×H)

Loading quantity

Net weight/Gross weight

Connection pipe diameter

HW24L-D HW48L-D HW60M-D HW60M-F HWR60M-F7034 14068 17585 17585 17500

24000 48000 60000 60000 600001/208-230/60 1/208-230/60 1/208-230/60 3/208-230/60 3/208-230/60

2219 4852 5800 6000 58009.80 35.20 45.40 19.30 22.40 1764 3530 3530 3530 35303000 6000 6000 6000 6000

60 63 65 65 66610×610×604651×651×629

710×710×718773×773×755

710×710×830773×773×857

710×710×830773×773×857

710×710×830773×773×857

50/53 70/75 91/96 80/85 90/95

162 90 90 90 90216 135 135 135 135

3/85/8

3/87/8

1/29/8

1/29/8

1/11-1/8

10 SEER / 50Hz

Model HWR24L-E HWR36L-E HWR36L-G HWR42L-G HWR60L-GW 7034 10550 10550 12309 17585

Btu/h 24000 36000 36000 42000 60000W 7034 10550 10550 12309 17585

Btu/h 24000 36000 36000 42000 60000Ph/V/Hz 1/230/50 1/230/50 3/380/50 3/380/50 60000

Cooling W 2006 4075 4075 3785 6736Heating W 1795 4075 4075 3784 6736Cooling A 12.5 18.9 10.3 9.8 15.8Heating A 10.6 18.6 10.5 10.3 15.6

m3/h1764 2650 2650 2650 3530CFM

3000 4500 4500 4500 6000dB(A) 60 63 63 63 65

Outline mmPackage mm

610×610×604651×651×629

610×610×718651×651×748

610×610×718651×651×748

610×610×832651×651×865

710×710×832773×773×857

kg 51/55 75/79 75/79 79/83 93/97Liquid inch

Gas inch

40’GP — 162 162 162 108 90

40’HQ — 216 162 162 162 135

Air flow volume

Net weight/Gross weight

Connection pipe diameter

Capacity Cooling

Heating

Power supply

Power input

Loading quantity

Heat pump

Dimension(W×D×H)

Current input

Sound pressure level

3/85/8

3/83/4

3/83/4

3/83/4

1/29/8

Model HW24L-E HW30M-E HW30M-G HW36L-E HW36L-G HW42L-G HW60L-GW 7038 8792 8792 10551 10550 12309 17585

Btu/h 24000 30000 30000 36000 36000 42000 60000Ph/V/Hz 1/230V/50 1/230V/50 3/380/50 3/380/50 3/380/50 3/380/501/230/50

W 2250 2760 2720 4490 4352 4150 5736A 13.8 18.9 6.4 21.6 11.1 10.6 15.8

CFMm3/h

dB(A) 60 62 62 63 63 63 65Outline mmPackage mm

610×610×604651×651×629

610×610×718651×651×748

610×610×718651×651×748

610×610×718651×651×748

610×610×718651×651×748

610×610×832651×651×865

710×710×832773×773×857

kg 46/50 68/73 68/71 68/73 68/73 75/78 87/91Liquid inchGas inch40’GP — 162 162 162 162 162 108 9040’HQ — 216 216 216 216 216 162 135

Cooling only

Connection pipe diameter

Air flow volume

Sound pressure level

Dimension(W×D×H)

Power input

Capacity

Power supply

Loading quantity

Rated current

Net weight/Gross weight 3/85/8

3/83/4

3/83/4

3/83/4

3/83/4

3/83/4

1/29/8

1764 2650 2650 2650 2650 2650 35303000 4500 4500 4500 4500 4500 6000

UNITARY UN

ITARY

Page 11: Gree   catalogo completo linha comercial 2012

COMMERCIALAIR CONDITIONERS

20COMMERCIAL AIR CONDITIONERS

19

Air Handler

Duct Split Unit

Operation range (temperature)

Outdoor condition

Heating 7 6 20 15

Cooling 35 24 27 19

Item

Nominal operating condition (temperature)

Outdoor condition Indoor condition

℃DB ( ) ℃WB ( ) ℃DB ( ) ℃WB ( ) ℃DB ( )

21~43 (without low ambient cooling)

-7~24

* Only available for heat pump model.

Model HNF36-R HNF48-R HNF60-RW 9965 14000 17580

Btu/h 34000 48000 60000Ph/V/Hz 1/220,50/60 1/220,50/60 1/208-230,50/60

kW 3800 4700 6500A 19 28 30.08

AC AC ACCFM 850 1760 1760m3/h 1443 2988 2988

Rate Pa 37 50 50Range Pa 0-120 0-160 0-160

dB(A) 56 59 60Outline mm 533×541×1124Package mm 597×572×1160

533×541×1240607×572×1280

533×541×1240607×572×1280

kg 55/59 60/64 66/70Liquid inchGas inch40'GP —

152 120 12040'HQ — 152 152 152

Connection pipe diameter

Loading quantity

Air flow volume

ESP

Sound pressure level

Dimension(W×D×H)

Net weight/Gross weight

Power inputRated currentMotor type

Cooling capacity

Power supply

3/85/8

3/83/4

1/29/8

Model HNTF24-R HNTF36-R HNTF48-R HNTF60-R

HNTFR24-R HNTFR36-R HNTFR48-R HNTFR60-RW 7000 10000 14000 17000

Btu/h 24000 36000 48000 60000W 8000 11000 15000 19000

Btu/h 27300 39600 51000 64500Ph/V/Hz 1/208/230,50/60 1/208/230,50/60 1/208/230,50/60 1/208/230,60

Cooling kW 2340 3065 4010 5010Heating* kW 2400 3150 4100 5100Cooling A 11.4 16.4 22.4 27Heating* A 12.1 18.1 24.5 29

CFM 647/589/559 589/530/500 1236/1206/1177 1236/1206/1177m3/h 1100/1000/950 1000/900/850 2100/2050/2000 2100/2050/2000dB(A) 50/48/46 50/48/46 57/52/46 57/52/46

Outline mm 1300×600×188 1300×600×188 1590×695×238 1590×695×238Package mm 1348×668×225 1348×668×225 1653×763×270 1653×763×270

kg 34/41 35/42 50/59 50/59Liquid inchGas inch

40'GP — 252 252 120 120

40'HQ — 252 252 126 126

Heat pump

CapacityCooling

Cooling only

Connection pipe diameter

Loading quantity

Heating*

Power input

Rated current

Air flow volume

Dimension(W×D×H)

Net weight/Gross weight

Sound pressure level

Power supply

3/85/8

3/85/8

1/23/4

1/23/4

Dual temperature sensor.

Anticorrosion heat exchanger,easy cleaning and less performance decline after years operation.

Thanks to optimized fan and air flue design that greatly improve the fan efficiency and lower the operation noise.

Five directions pipe connection connector to meet various installation environments.

Flexible air inlet/outlet direction and condensing water outlet direction, meet various installation environments.

Qualitymotor

High ESP

Compactdesign

Easiermaintainability

Comprehensiveprotection

It is a kind of split system that can be connected with air duct to realize cooling or heating in subdivided area.

FG20T3/B-F FG25T3/B-F FG30T3/B-F FG40T3/B-F FG50T3/B(2)-F FG60T3/B(2)-FFGR20T3/B-F FGR25T3/B-F FGR30T3/B-F FGR40T3/B-F FGR50T3/B(2)-F FGR60T3/B(2)-F

kW 19.5 24.5 29.5 39.5 49 59Btu/h 66537 83598 100658 134779 167196 201316kW 22 27 32.5 42 54 65

Btu/h 75067 92128 110895 139897 184256 221718W/W 2.29/3.14 2.40/3.10 2.22/3.10 2.32/3.00 2.40/3.10 2.34/3.32

Ph/V/Hz

kW 8.5 10.2 13.3 17 20.4 25.2kW 6.8 8.7 10.5 14 17.4 19.6A 38 32.5 45.5 63 66.4 87A 26 27.8 39.5 49 57 75kg 6.5 8.5 10.5 11.8 17 21

CFM 2354 2825 3237 4120 5297 6474

4000 4800 5500 7000 9000 11000Rated Pa 90 120 140 150 170 190Range Pa 30-200 30-200 30-250 30-250 30-250 30-250

dB(A) 54 56 57 59 59 60Outline mm 1500×1000×500 1700×1100×650Package mm 1840×1200×673

1500×1000×500

1840×1200×673

1500×1000×500

1840×1200×673 1890×1460×835

1900×1100×850

2090×1460×1040

1900×1100×700

2090×1460×885

Kg 150/200 150/200 170/220 210/260 315/365 325/375dB(A) 68 68 68 69 68 68

Outline mm 990×880×1772Package mm 1162×980×1950

990×880×1772

1162×980×1950

990×880×1772

1162×980×1950

1290×880×1772

1370×980×1950

990×880×1772

1162×980×1950

990×880×1772

1162×980×1950

Cooling only Kg 205/235 215/245 240/270 290/320 215/245 240/270Heat pump* Kg 220/250 225/255 250/280 300/330 225/255 250/280Liquid inch 5/8 5/8 5/8 5/8 5/8 5/8Gas inch 11/8 11/8 11/8 13/8 11/8 11/8Height m 30 30 30 30 30 30Length m 50 50 50 50 50 5040'GP/40'HQODU

IDU

— 24/24 24/24 24/24 16/16 12/12 12/12

40'GP/40'HQ — 26/26 26/26 26/26 14/21 16/22 16/16Loading quantity

Current input

Dimension (W×D×H)

Capacity

Cooling

Heating*

EER/COP*

Power supply

Power inputCooling

Heating*

Sound pressure level(H/M/L)

Dimension (W×D×H)

3/220/60 3/220/60 3/220/60 3/220/60 3/220/60 3/220/60

Cooling

Connection pipe

Outer diameter

Max. distance

Refrigerant charged volume

Indoor unit

Heating*

Model Cooling onlyHeat pump

Net weight/Gross weight

Outdoor unit

Net weight/ Gross weight

Air flow volume

ESP

Sound pressure level(H/M/L)

* Only available for heat pump model.

m3 /h

20/25/30kW 40kW 50/60kW

UNITARY UN

ITARY

Page 12: Gree   catalogo completo linha comercial 2012

It is a kind of packaged air conditioner that can be installed either on ground or roof and widely used in villa, hotel, school, supermarket and factory.

COMMERCIALAIR CONDITIONERS

22COMMERCIAL AIR CONDITIONERS

21

Rooftop Packaged Unit

Thanks to aluminum micro channel heat exchanger that gets a 30% higher of efficiency and a 40% lighter of weight(only for high effienciency series).

Range of 5~30kw electric heater is optional for heating.

The static pressure of the unit is in range of 25~250Pa. It make the blowing distance far away.

Flexible air inlet/outlet direction meets different installation requirements.

Thermostat with LCD display is optional.

Washablefilter

Comprehensiveprotection

High ESP

23.9 26.7 19.4

8.3 6.1 21.1 15.6

Operation range (temperature)

Outdoor condition

Heating

Cooling 35

Item

Nominal operating condition (temperature)

Outdoor condition Indoor condition

DB ( )℃ WB ( )℃ WB ( )℃ WB ( )℃ DB ( )℃

19.4~46.1

-8.3~23.9

Auxiliary electricheater

Easiermaintainability

T1

Model kW

RT

Btu/h.W

kW

Ph/V/Hz

kW

A

Kgl/h

m3 /h

CFMPa

Pa

dB(A)

inch

mm

Outline mmPackage mm

Net weight /Gross weight Kg

40'GP —40'HQ —

EER/COP*

Refrigerant charge volume

Dimension (W×D×H)

Current input

Capacity

Sound pressure level

Condensation water pipe

ESP

Power input

Power supply

Auxiliary heater capacity (optional)

Dehumidifying volume

Air flow volume

Cooling only

Loading quantity

GK-C14003NC3AD GK-C14004NC3AD GK-C14005NC3AD GK-C14005NC3AF10.5 14 17.5 17.5

3 4 5 5

11.3 12 11.3 11.8

/ / / /

1/208-230/60 1/208-230/60 1/208-230/60 3/208-230/60

3.2 4 5.3 5.1

14.4 18.4 23.5 14.8

2.9 2.5 2.6 2.5

6.5 6.5 8 8

1800 2700 3000 3000

1059 1589 1765 1765

37 50 50 50

0-75 0-75 0-75 0-75

66 66 66 66

3/4 3/4 3/4 3/4

19.05 19.05 19.05 19.05

1490×1090×1090

1530×1120×1125

1490×1090×1090

1530×1120×1125

1490×1090×1090

1530×1120×1125

1490×1090×1090

1530×1120×1125

255/270 255/270 260/275 260/275

30 30 30 30

30 30 30 30

Model kW

RT

Btu/h.W

kW

Ph/V/Hz

kW

A

Kg

l/h

m3 /h

CFM

PaPa

dB(A)

inch

mm

Outline mm

Package mm

Kg

40'GP —

40'HQ —

Refrigerant charge volume

Dimension (W×D×H)

Current input

Capacity

Sound pressure level

Condensation water pipe

ESP

Power input

Auxiliary heater capacity (optional)

Power supply

Dehumidifying volume

Air flow volume

Cooling only

Loading quantity

GK-C03NC1AD GK-C04NC1AD GK-C05NC1AD GK-C05NC1AF10.5 14 17.5 17.5

3 4 5 5

9 9 9 9

5/10 5/10 5/10 5/10

1/220/60 1/220/60 1/220/60 3/220/60

4.42 6.29 6.2 6.05

21 30 30 18.6

1.8 2.8 4.15 4.15

3.6 4.5 6.2 6.2

1630 1750 2400 2400

962 1030 1412 1412

25 25 75 75

0-75 0-75 0-150 0-150

65 67 67 69

3/4 3/4 3/4 3/4

19.05 19.05 19.05 19.05

1345×1055×640

1392×1100×665

1345×1055×640

1392×1100×665

1345×1055×790

1392×1100×815

1345×1055×790

1392×1100×815

185/190 185/190 205/215 205/215

48 48 32 32

64 64 48 48

EER/COP*

Net weight /Gross weight

T3Model

kW

RT

Btu/h.W

kW

Ph/V/Hz

kW

A

Kg

l/h

m3 /h

CFM

Pa

dB (A)

inch

mm

Outline mm

Package mm

Kg40'GP —

40'HQ —

Refrigerant charge volume

Dimension (W×D×H)

Current input

Capacity

Sound pressure level

Condensation water pipe

ESP Rated

Power input

Power supply

Dehumidifying volume

Air flow volume

Cooling only

Loading quantity

GK-C08TC1AF GK-C10TC1AF GK-C15TC1AF GK-C20TC1AF GK-C25TC1AF GK-C30TH1AF28 35 50 70 87.5 105

8 10 15 20 25 30

8 8 8 8 8 105

10/15/20 10/15/20 20/25/30 20/25/30 20/25/30 30

3/220/60 3/220/60 3/220/60 3/220/60 3/220/60 3/220/60

12.7 15.3 23.8 28 44 47

45 47 80 98 140 150

2×3.6 2×4 5.3+6.0 2×10 12+11.5 12+12

7.5 10 15.6 15.6 26 15.6

5500 7500 10000 14000 17500 15500

3245 4425 5900 8260 10324 9144

100 100 200 200 250 250

70 73 75 78 81 78

3/4 3/4 3/4 1 1 1

19.05 19.05 19.05 25.4 25.4 25.4

2006×1436×1117

2046×1466×1152

2006×1436×1117

2046×1466×1152

2205×1610×1190

2245×1640×12252870×2120×1375

2950×2198×1555

2870×2120×1375

2950×2198×1555

2870×2120×2283

2950×2198×2463

455/485 470/500 640/679 1005/1170 1049/1214 1200/1350

16 16 7 4 4 4

16 16 14 4 4 4

EER/COP*

Net weight /Gross weight

Auxiliary heater capacity (optional)

3/4RT 5RT

8/10RT 20/25RT 30RT

3/4/5/6RT

15RT

UNITARY UN

ITARY

T1,R410A

T3,R22

T1,R22

Page 13: Gree   catalogo completo linha comercial 2012

FREE MATCH

COMMERCIALAIR CONDITIONERS

24COMMERCIAL AIR CONDITIONERS

23

FREE M

ATCH

Page 14: Gree   catalogo completo linha comercial 2012

COMMERCIALAIR CONDITIONERS

26COMMERCIAL AIR CONDITIONERS

25

Cooling 35

Heating 7

24

6

27

20

19 -5~48

15 -15~27

Operation range (temperature)Outdoor condition

Nominal operating condition (temperature)Outdoor condition Indoor condition

DB (。C) WB (

。C) DB (

。C)WB (

。C)DB (

。C)

Item

Free MatchIt’s a kind of DC inverter multi-split air conditioner that consisted with one outdoor unit and up to five indoor units.

Intelligentdefrosting

High efficiency

Quiet function

Comprehensiveprotection

Compactdesign

Various series of indoor units from wall-mounted type to duct type can satisfy different kinds of requirements. Powered by GREE G10 Inverter technology, the unit operates with lower power consumption, lower noise, more comfort. The unit is designed with low temperature cooling function, can operate cooling mode under outdoor ambient of -15。C.

9+1212

9+9

One unit

9

Two units

GWHD(18)ND3CO

4 Combinations

Outdoor Units and Indoor Units Lineup

Btu/h

Hansol

U-CoolWallmounted

Artful

Cozy

Console

Duct

Cassette

Floor ceiling

9000 12000 18000 21000 24000

16 CombinationsTwo unit

9+9

9+1812+18

9+12

12+1218+18

9+9+9

9+12+1212+12+18

9+9+12

9+12+18

9+9+18

12+12+12

9+9+9+9 9+9+9+12 9+9+12+12Three units Four units

GWHD(30)ND3CO - ---

--

--

-

-

--- -

-

--

47 Combinations

9+99+129+189+219+24

12+1212+1812+21

12+2418+1818+2118+2421+2121+2424+24

9+9+99+9+129+9+189+9+219+9+24

9+12+129+12+189+12+21

9+12+249+18+189+18+219+18+249+21+21

12+12+1212+12+1812+12+21

12+12+2412+18+1812+18+2118+18+18

9+9+9+99+9+9+129+9+9+189+9+9+219+9+9+24

9+9+12+129+9+12+189+9+12+21

9+9+18+189+12+12+129+12+12+1812+12+12+12

Two units Three units Four units

GWHD(36)NK3AO

----

-

-

-

-

-

-

-

-

-

87 CombinationsTwo units Three units Four units Five units

GWHD(42)NK3AO

9+99+129+189+219+2412+1212+1812+2112+2418+18

18+2118+2421+2121+2424+24

9+9+99+9+129+9+189+9+219+9+249+12+129+12+189+12+219+12+249+18+18

9+18+219+18+249+21+219+21+249+24+2412+12+1212+12+1812+12+2112+12+2412+18+18

12+18+2112+18+2412+21+2112+21+2412+24+2418+18+1818+18+2118+18+2418+21+2121+21+21

9+9+9+99+9+9+129+9+9+189+9+9+219+9+9+249+9+12+129+9+12+189+9+12+219+9+12+249+9+18+18

9+9+18+219+9+18+249+9+21+219+12+12+129+12+12+189+12+12+219+12+12+249+12+18+189+12+18+219+12+21+21

9+18+18+1812+12+12+1212+12+12+1812+12+12+2112+12+12+2412+12+18+1812+12+18+21

9+9+9+9+99+9+9+9+129+9+9+9+189+9+9+9+219+9+9+9+249+9+9+12+129+9+9+12+189+9+9+12+219+9+9+18+189+9+12+12+12

9+9+12+12+189+9+12+12+219+12+12+12+129+12+12+12+1812+12+12+12+12

Outdoor UnitModel Heat Pump GWHD(42)NK3AOGWHD(24)ND3CO

39500 (11900-46400)44300 (15300-47700)

16208-230/60

3590 (1300-4900)3545 (1300-4400)

571015×440×11031155×490×1220

102/112 15.9 9.52

4848

26000(7500-33000)29000(7500-35000)

161/208-230/60

3050(650-4500)2800(980-3950)

59955×700×396

1018×840×45861/66 9.52 6.00171171

GWHD(36)NK3AO33400 (10200-34100)37500 (15300-40900)

15208-230/60

3030 (1300-4600)3010 (1300-4140)

56950×412×840

1103×453×92073/78 15.9 9.52

108108

GWHD(30)ND3CO29000(7500-34000)30500(7500-36000)

161/208-230/60

3450(650-4500)2850(980-3950)

59955×700×396

1029×750×45862/67 9.52 6.00171171

GWHD(18)ND3CO18000(7000-21000)19000(8530-22600)

161/208-230/60

1650(680-2800)1640(680-2800)

56899×596×378948×645×420

43/48 9.52

6.00 204272

Heating

Heating

Cooling

Cooling

SEER

Power input

Sound pressure level

Power supply

Capacity

Dimension (W×H×D)

Net weight/Gross weight

Loading quantity

PackageOutline

40'HQ

Btu/hBtu/hW/W

Ph/V/HzWW

dB(A)

Connecting pipediameter

GasLiquid

mmmm

mmmmkg

40'GP--

Note:Outdoor unit for 36K Btu/h has 4 sets of piping connection:1. 15.9mm(Gas), 9.52mm(Liquid); 2. 12.7mm(Gas), 6.35mm(Liquid); 3. 9.52mm(Gas), 6.35mm(Liquid); 4. 9.52mm(Gas), 6.35mm(Liquid). Outdoor unit for 42K Btu/h has 5 sets of piping connection:1. 15.9mm(Gas), 9.52mm(Liquid); 2. 12.7mm(Gas), 6.35mm(Liquid); 3. 12.7mm(Gas), 6.35mm(Liquid); 4. 9.52mm(Gas), 6.35mm(Liquid);5. 9.52mm(Gas), 6.35mm(Liquid).

11 Combinations

9+12+12

9+9+1812+12+12

Two units9+9

9+1812+18 18+18

9+12

12+12

9+9+9

9+9+12

Three units

GWHD(24)ND30CO -

FREE MATCHFR

EE MATC

H

Page 15: Gree   catalogo completo linha comercial 2012

COMMERCIALAIR CONDITIONERS

28COMMERCIAL AIR CONDITIONERS

27

Model GWH18MC-D3DNA3D/I 1800019800850

46/44/40/35940×298×2001013×288×395

13/17558619

GWH12MB-D3DNA3D/I1200013000580

42/38/36/28845×275×180918×258×370

10/13684798

GWH09MB-D3DNA3D/I90009800560

41/37/35/26845×275×180918×258×370

10/13684798

Cozy

Heating

Package

Cooling

Outline

Airflow volume

Dimension(W×H×D)

Sound pressure level (SH/H/M/L)

Capacity

Net weight/Gross weight

Loading quantity40'GP40'HQ

Btu/hBtu/hm3/h

mmmmkg

dB(A)

-

-

Model GWH18AC-D3DNA1D/I1800019800830

46/43/40/35960×300×1951038×393×295

13/18512576

GWH12AB-D3DNA1D/I1200013000600

44/38/30/28872×283×178938×378×275

11/15600675

GWH09AB-D3DNA1D/I90009800580

43/38/30/28872×283×178938×378×275

11/15600675

Artful

Heating

Package

Cooling

Outline

Airflow volume

Dimension(W×H×D)

Sound pressure level (SH/H/M/L)

Capacity

Net weight/Gross weight

Loading quantity40'GP40'HQ

Btu/hBtu/hm3/h

mmmmkg

dB(A)

--

Model GWH18UC-D3DNA1A/I1800019800850

44/40/37/35/33/31/28998×340×1781083×428×283

15/19440495

GWH12UB-D3DNA1A/I1200013000560

42/39/37/34/31/28/26896×320×159973×403×255

12/15585650

GWH09UB-D3DNA1A/I90009800500

41/37/35/32/30/28/25896×320×159973×403×255

12/15585650

U-Cool

Heating

Package

Cooling

Outline

Airflow volume

Dimension(W×H×D)

Sound pressure level (SH/H/MH/M/ML/L/SL)

Capacity

Net weight/Gross weight

Loading quantity40'GP40'HQ

Btu/hBtu/hm3/h

mmmmkg

dB(A)

-

-

Model GTH(24)BA-D3DNA1A/I24200273001250

481220×700×2251343×823×315

45/549696

GTH(12)BA-D3DNA1A/I120001300065040

1220×700×2251343×823×315

40/509696

GTH(18)BA-D3DNA1A/I170001880095045

1220×700×2251343×823×315

40/509696

GTH(09)BA-D3DNA1A/I8500960065040

1220×700×2251343×823×315

40/509696

Floor Ceiling Type Indoor Unit

Heating

Package

Cooling

Outline

Airflow volume

Dimension(W×H×D)

Sound pressure level

Capacity

Net weight/Gross weight

Loading quantity40'GP40'HQ

Btu/hBtu/hm3/h

mmmmkg

dB(A)

--

Cassette Type Indoor UnitModel GKH(24)BA-D3DNA1A/I

2420027300118039/35

840×840×240963×963×325

18/23950×950×60

1043×1028×1302.5108128

GKHD(18)ABND3A2AI1800019500860

47/44/39600×230×600848×310×678

20/28650×50×650

730×102×6702.5234280

GKHD(12)ABND3A2AI1200013500580

44/40/36600×230×600848×310×678

20/27650×50×650

730×102×6702.5234280

Heating

Package

Cooling

Outline

PackageOutline

Airflow volume

Main body

Sound pressure level (H/M/L)

Capacity

Loading quantity

Net weight/Gross weight

Net weight/Gross weight

Dimension(W×H×D)

Dimension(W×H×D) Panel

40'GP40'HQ

Btu/hBtu/hm3/h

mmmmkg

mmmmkg

dB(A)

--

Duct Type Indoor UnitModel GFH(24)EA-D3DNA1A/I

2420027300100042/34

1100×615×2001323×743×305

31/41162162

GFH(18)EA-D3DNA1A/I1700018800700

40/33900×615×200

1123×743×30527/36180180

GFH(12)EA-D3DNA1A/I1200013000550

39/32700×615×200893×743×305

23/29234234

GFH(21)EA-D3DNA1A/I2000022500100042/34

1100×615×2001323×743×305

31/41162162

GFH(09)EA-D3DNA1A/I85009600450

37/31700×615×200893×743×305

22/27234234

Heating

Package

Cooling

Outline

Airflow volume

Dimension(W×H×D)

Sound pressure level (H/L)

Capacity

Net weight/Gross weight

Loading quantity40'GP40'HQ

Btu/hBtu/hm3/h

mmmmkg

dB(A)

--

Wall Mounted Indoor Unit

Model GWH18TC-D3DNA1A/I1800019000950

49/44/41/39/36/33/301018×319×2301097×397×340

15/20402464

GWH12TB-D3DNA1A/I1200013000800

44/37/35/33/31/30/29866×292×209945×297×377

11/14590668

GWH09TB-D3DNA1A/I90009800750

43/36/34/32/30/29/28866×292×209945×297×377

11/14590668

Hansol

Heating

Package

Cooling

Outline

Airflow volume

Dimension(W×H×D)

Sound pressure level (SH/H/MH/M/ML/L/SL)

Capacity

Net weight/Gross weight

Loading quantity40'GP40'HQ

Btu/hBtu/hm3/h

mmmmkg

dB(A)

--

Model GEH(18)AA-D3DNA1C/I1800019800

65048/46/44/41/37/35/33

700×600×215788×695×283

15/18380426

GEH(12)AA-D3DNA1C/I1200013000600

43/40/38/37/35/32/27700×600×215788×695×283

15/18380426

GEH(09)AA-D3DNA1C/I90009500500

40/38/36/33/30/26/25700×600×215788×695×283

15/18380426

Heating

Package

Cooling

Outline

Airflow volume

Dimension(W×H×D)

Sound pressure level (SH/H/MH/M/ML/L/SL)

Capacity

Net weight/Gross weight

Loading quantity40'GP40'HQ

Btu/hBtu/hm3/h

mmmmkg

dB(A)

--

Console

FREE MATCHFR

EE MATC

H

Page 16: Gree   catalogo completo linha comercial 2012
Page 17: Gree   catalogo completo linha comercial 2012
Page 18: Gree   catalogo completo linha comercial 2012
Page 19: Gree   catalogo completo linha comercial 2012
Page 20: Gree   catalogo completo linha comercial 2012
Page 21: Gree   catalogo completo linha comercial 2012

MODULAR AIR-COOLED SCROLL CHILLERMODULAR AIR-COOLED SCREW CHILLER

CHILLER

CH

ILLER

COMMERCIAL AIR CONDITIONERS

39COMMERCIAL

AIR CONDITIONERS

40

CH

ILLER

Page 22: Gree   catalogo completo linha comercial 2012

Running condition real-time display.

Low start-up current thanks to power delay control design.

Unique compressor alternation operation technology largely prolong the lifespan of compressor.

Double-flow design makes a higher heat exchange efficiency.

Special top cover design: make a better cooling capacity of 5% improvement and higher heat exchanging efficiency of 3% improvement.

Main module patent: any unit can be set as main module via wired controller.

Up to 16 units can be combined freely to get a max capacity of 1280kw thanks to modular design.

Auto anti-freezing function under heating mode when the unit is switched.

Modular Air-cooled Scroll Chiller Modular Air-cooled Screw Chiller (With Heat Recovery Function)

It is a kind of air-cooled screw chiller that can be connected to all sorts of fan coil unit to realize cooling/heating for civil or industrial buildings.

Running condition real-time display. Low start-up current thanks to power delay control design.

Multistep adjustment plus modular design makes a better unloading capacity that ensures the stability of water temperature.

Double spray cooling design to both compressor chamber and motor, ensure the reliability operation of motor and discharging bearing.

Well radiating and waterproof of electric control box thanks to special waterproof design.

Double-flow design makes a higher heat exchange efficiency.

Main module patent: any unit can be set as main module via wired controller.

Up to 8 units can be integrated freely to get a max. capacity of 3440kw thanks to modular design.

Auto anti-freezing function under heating mode when the unit is switched off.

Inner groove copper

Modular structure

Self-diagnosis

24 hour timerMemory function

Long-distance monitoring

Comprehensive protection

COMMERCIAL AIR CONDITIONERS

41

It is a kind of air-cooled scroll chiller that can be connected to all sorts of fan coil unit to realize cooling/heating for civil or industrial buildings.

(℃) φ ×

Operating range

Cooling

Heating

0.172 7 5~15 2.5~8 35 5~ 46

Nominal operating condition Operating range

Water side (water temperature) Air side (outdoor temperature)

Nominal operating conditionItem

DB (℃)I/O difference (℃)Outlet (℃)Outlet (℃) WB (℃) DB (℃)

0.172 45 40~50 2.5~8 7 -15~ 246

Water flow volume [m3/(h·kw)]

Model Cooling only

TypeStarting mode

Type

Connection pipeType

Fan type and quantity

Total fan motor power

Outline(W×D×H)Package(W×D×H)

Loading quantity 40'GP/40'HQ

Total fan air flow

Sound pressure level

Dimension

Net/Gross/Operating weight

Air side heatexchanger

Capacity steps

Capacity/Heat recovery

EERPower supply

Power input

Compressor

Water side heatexchanger

Water flow volume

Pressure drop

Quantity

kW

TR%

W/W

Ph/V/HzkW——

(℃) φ ×

Operating range

Cooling

Heat recovery

0.172 7 5~15 2.5~8 35 18~52

Nominal operating condition Operating range

Water side (water temperature) Air side (outdoor temperature)

Nominal operating conditionItem

DB (℃)I/O difference (℃)Outlet (℃)Outlet (℃) WB (℃) DB (℃)

0.172 7 15~55 2.5~8 35 18~52

Water flow volume [m3/(h·kw)]

——

l/s

GPMkPa

ft.WG

CFMkW

dB(A)mmmm

kgset

High-efficient fin tubeHigh-efficient fin tube High-efficient fin tube

LSBLGF230MR/Nb-H LSBLGF350MR/Nb-H LSBLGF430MR/Nb-H

Shell and tube

Semi-hermetic screwY—△ or Part winding

Shell and tube

Semi-hermetic screwY—△ or Part winding

Shell and tube

Semi-hermetic screwY—△ or Part winding

m3/h

230/6965/20

25-50-75-1002.88/-

3/380/6080

1

39.6 174 ≤50≤16

DN100

axial×410×104

5.9×104

2.0×478

3150×2100×23003230×2180×23003400/3420/3740

0/3

350/105100/30

25-50-75-1002.80/-

3/380/60125

1

60.2 265 ≤50≤16

DN100

axial×615×104

8.8×104

2.0×679

4330×2100×23004410×2180×23004800/4820/5280

0/2

430/129122/37

25-50-75-1002.83/-

3/380/60152

1

74.0 326 ≤50≤16

DN125

axial×820×104

11.8×104

2.0×880

5250×2100×23005330×2180×23005650/5670/6215

0/2

ModelHeat pump

Capacity Cooling/Heating*

Cooling only

Cooling/Heating*

TypeStarting mode

Type

Connection pipeType

Fan type and quantity

Total fan motor power

Outline(W×D×H)Package(W×D×H)

Cooling onlyHeat pump

Loading quantity 40'GP/40'HQ

Total fan air flow

Sound pressure level

Dimension

Net/Gross/Operating weight

Air side heat exchanger

Capacity stepsEER/COPPower supplyPower input

Compressor

Water side heat exchanger

Water flow volume

Pressure drop

Quantity

kW

TR%

W/W

Ph/V/HzkW

——

——

——

l/s

GPMkPa

ft.WG

l/sCFMkW

dB(A)mmmm

kgkgset

62.5/70.0 71.5/80.017.8/19.9 20.3/22.7 0-50-100 0-50-1002.52/2.90 2.68/3.00

24.8/24.1 26.7/26.7 Hermetic scroll Hermetic scrollDirect starting Direct starting

2 2

3.0 3.4 47.6 54.230 359.8 11.5

DN50 DN50

axial×3 axial×3

0.8×104

1.8×104

0.9×104

1.9×104

0.7×3 0.7×367 68

1100×2265×2214 1100×2265×22141130×2295×2214 1130×2295×2214

900/910/990 1000/1010/1100950/960/1045 1050/1060/1155

10/10 10/10

High-efficient fin tube type heat exchanger

LSQWF65MG/NaC-F LSQWF80MG/NaC-FLSQWRF65MG/NaC-F LSQWRF80MG/NaC-F

3/220/60 3/220/60

Shell and tube heat exchanger

High-efficient fin tube type heat exchanger

Shell and tube heat exchanger

C Series

Golden fincondenser

Inner groove copper

Modular structure

Self-diagnosis 24 hour timerMemory function

Long-distance monitoring

Comprehensive protection

Golden fincondenser

Easier maintainability

*Only available for heat pump unit.

COMMERCIALAIR CONDITIONERS

42

Chiller C

HILLER

Page 23: Gree   catalogo completo linha comercial 2012

FAN COIL UNITAIR HANDLING UNITDIFFUSER

TERMINAL

COMMERCIALAIR CONDITIONERS

44COMMERCIAL AIR CONDITIONERS

43

TERM

INAL

Page 24: Gree   catalogo completo linha comercial 2012

Fan Coil Unit

It is a kind of fan coil unit that is connected to the chillers to realize cooling/heating for civil or residential use.

COMMERCIALAIR CONDITIONERS

46COMMERCIAL AIR CONDITIONERS

45

Inner groovecopper

Washablefilter

Quiet function

Multi fanspeed

Compactdesign

Item DB (℃) WB (℃) Inlet (℃) Outlet (℃)

Cooling 27 19 7 12

Heating 21 — 60 —

Nominal test condition (temperature)

3 Rows

3 Rows

4 Rows

Model FP 34WAS R FP 51WAS R FP 68WAS R FP 85WAS R FP 102WAS R FP 136WAS RHigh CFM 200 300 400 500 600 800Medium CFM 146 232 291 375 464 644Low CFM 125 155 194 250 309 429

Pa 30 30 30 30 30 30Cooling kW 2.19 3.37 4.28 5.04 6.46 8.17Heating kW 3.29 5.06 6.42 7.56 9.7 10.9Type Ph/V/HzInput W 44 59 72 87 108 156Water flow volume l/s 0.11 0.17 0.22 0.25 0.32 0.37

kPa 10 15 25 30 40 20

Ft·WG 3.3 5 8.4 10 13.3 6.7

dB(A) 38 40 42 44 46 47

Water inlet & outlet inchCondensed water drain inch

Outline mm 881×510×245 1011×510×245 1131×510×245 1211×510×245 1371×510×245 1761×510×245Package mm 900×560×275 1030×560×275 1150×560×275 1230×560×275 1390×560×275 1780×560×275

kg 15/19 16/20.5 18/23 19.5/24.5 21/26 30/35

40'GP — 448 392 344 316 268 22040'HQ —

——

490 434 386 355 301 247

HF31 HF32 HF33 HF34 HF35 HF36HF41 HF42 HF43 HF44 HF45 HF46

1/220-230/60 1/220-230/60 1/220-230/60 1/220-230/60 1/220-230/60 1/220-230/60Power system

Capacity

ESP

Air flow volume

Connection pipe diameter

Sound pressure level

Pressure dropWater system

LCD controller: WK-110PA0

Plenum without filterPlenum with filterWired remote controller

Optionals

Loading quantity

Net weight/Gross weight

Dimension(W×D×H)

Luxury wired controller: WK-010PA-K;

ModelHigh CFMMedium CFMLow CFM

PaCooling kW

Heating kW

Type Ph/V/HzInput WWater flow volume l/s

kPa

Ft·WGdB(A)

Water inlet & outlet inch

Condensed water drain inch

Outline mmPackage mm

kg

40'GP —40'HQ —

——

1/220-230/60 1/220-230/60 1/220-230/60 1/220-230/60 1/220-230/60 1/220-230/60Power system

Capacity

ESP

Air flow volume

Connection pipe diameter

Sound pressure level

Pressure dropWater system

Plenum without filterPlenum with filter

Wired remote controllerOptionals

Loading quantity

Net weight/Gross weight

Dimension(W×D×H)

FP 170WAS R FP 204WAS R FP 238WAS R FP 272WAS R FP 306WAS R FP 340WAS R

1000 1200 1400 1600 1800 2000750 926 971 1235 1006 1400500 618 729 868 674 81230 30 30 30 30 30

11.4 12.16 12.4 13.5 16 1718.2 18.55 19.5 21.3 24.8 26.1

174 212 380 475 535 6400.55 0.57 0.57 0.64 0.74 0.79

38 45 21.9 27.9 37.5 41.212.7 15 7.3 9.3 12.5 13.7

49 52 56 59 62 63

1921×510×245 1921×510×245 1671×595×354 1671×595×354 1921×595×354 1921×595×3541940×560×275 1940×560×275 1750×650×380 1750×650×380 1950×650×380 1950×650×380

33/38.5 24/39.5 48/55 48/55 52/60 52/60

196 196 140 140 130 130220 220 166 166 153 153

HF37 HF37 HF28 HF28 HF29 HF29HF47 HF47 HF48 HF48 HF49 HF49

LCD controller: WK-110PA0Luxury wired controller: WK-010PA-K;

ModelHigh CFMMedium CFMLow CFM

PaCooling kWHeating kW

Type Ph/V/HzInput WWater flow volume l/s

kPa

Ft·WGdB(A)

Water inlet & outlet inchCondensed water drain inch

Outline mmPackage mm

kg

40'GP —40'HQ —

——

1/220-230/60 1/220-230/60 1/220-230/60 1/220-230/60 1/220-230/60 1/220-230/60Power system

Capacity

ESP

Air flow volume

Connection pipe diameter

Sound pressure level

Pressure dropWater system

Plenum without filterPlenum with filter

Wired remote controllerOptionals

Loading quantity

Net weight/Gross weight

Dimension(W×D×H)

FP 34WAF R FP 51WAF R FP 68WAF R FP 85WAF R FP 102WAF R FP 136WAF R188 289 383 477 571 760156 259 324 368 507 61680 186 207 242 395 42430 30 30 30 30 30

2.11 3.82 4.85 5.71 7.32 9.263.7 5.7 7.2 8.5 10.9 13.8

44 59 80 87 108 1560.11 0.19 0.24 0.31 0.35 0.43 15 7.8 9.7 23.3 35.5 16.45 2.6 3.2 7.8 11.8 5.5 40 42 44 47 49 50

1011×510×245 1131×510×245 1211×510×245 1371×510×245 1761×510×245881×510×245

900×560×275 1030×560×275 1150×560×275 1230×560×275 1390×560×275 1780×560×27514.4/18.9 17.2/21.9 19.2/24.1 20.5/25.6 23.2/28.7 34.2/40.5

448 392 344 316 268 220

490 434 386 355 301 247

HF31 HF32 HF33 HF34 HF35 HF36HF41 HF42 HF43 HF44 HF45 HF46

LCD controller: WK-110PA0Luxury wired controller: WK-010PA-K;

Concealed Ceiling Type

Thanks to optimized air flue design that greatly improve the fan efficiency and lower the operation noise.

Flexible air inlet/outlet directions, meet different installation requirements.

Washable filter is optional when equiped with air return box.

3/4(outer groove)3/4(inner groove)

3/4(inner groove)

3/4(outer groove)

3/4(inner groove)3/4(outer groove)

ModelHigh CFMMedium CFMLow CFM

PaCooling kW

Heating kW

TypeInput WWater flow volume l/s

kPa

Ft·WGdB(A)

Water inlet & outlet inchCondensed water drain inch

Outline mmPackage mm

kg

40'GP —

40'HQ ———

Power system

Capacity

ESP

Air flow volume

Connection pipe diameter

Sound pressure level

Pressure dropWater system

Plenum without filterPlenum with filterWired remote controller

Optionals

Loading quantity

Net weight/Gross weight

Dimension(W×D×H)

FP 170WAF R FP 204WAF R FP 238WAF R FP 272WAF R FP 306WAF R FP 340WAF R948 1043 1400 1600 1800 2000750 926 971 1235 1006 1400500 618 729 868 674 81230 30 30 30 30 30

11.4 12.16 14.28 16 18.7 19.818.2 20.6 21.42 24 28.05 29.7

174 212 380 475 535 6400.51 0.58 0.78 0.89 1.02 1.13 23.9 31.5 29.2 21.7 26.2 32.58.0 10.5 9.7 7.2 8.7 10.8 51 52 56 58 60 61

1921×510×245 1921×510×245 1671×595×354 1921×595×3541940×560×275 1940×560×275 1750×650×380

1671×595×3541750×650×380 1950×650×380

1921×595×3541950×650×380

37.5/44 37.5/44 52/60 52/60 59/66 59/66

196 196 140 140 130 130

220 220 166 166 153 153

HF37 HF37 HF28 HF28 HF29 HF29HF47 HF47 HF48 HF48 HF49 HF49

LCD controller: WK-110PA0Luxury wired controller: WK-010PA-K;

Ph/V/Hz 1/220-230/60 1/220-230/60 1/220-230/60 1/220-230/60 1/220-230/60 1/220-230/60

3/4(inner groove)3/4(outer groove)

TERM

INAL

TERMINALTER

MIN

AL

Page 25: Gree   catalogo completo linha comercial 2012

COMMERCIALAIR CONDITIONERS

48COMMERCIAL AIR CONDITIONERS

47

Inner groove copper

3+1 RowsModel

High CFMMedium CFMLow CFM

PaCooling kW

Heating kW

TypeInput WWater flow volume l/s

kPa

Ft·WGdB(A)

Water inlet & outlet inchCondensed water drain inch

Outline mmPackage mm

kg

40'GP —40'HQ —

——

Power system

Capacity

ESP

Air flow volume

Connection pipe diameter

Sound pressure level

Pressure dropWater system

Plenum without filterPlenum with filterWired remote controller

Optionals

Loading quantity

Net weight/Gross weight

Dimension(W×D×H)

FP 34WAT R FP 51WAT R FP 68WAT R FP 85WAT R FP 102WAT R FP 136WAT R188 289 383 477 571 760156 259 324 368 507 61680 186 207 242 395 42430 30 30 30 30 30

1.95 3.07 3.88 4.55 5.82 7.351.76 2.49 3.17 3.83 4.85 6.69

44 59 80 87 108 1560.11 0.17 0.21 0.29 0.32 0.39 10.6 23.3 18.2 38 56.5 16.83.5 7.8 6.1 12.7 18.8 5.6 40 42 44 47 49 50

881×510×245 1011×510×245 1131×510×245

900×560×275 1030×560×275 1150×560×275

1211×510×245

1230×560×275

1371×510×245

1390×560×275

1761×510×245

1780×560×27514.4/18.9 17.2/21.9 19.2/24.1 20.5/25.6 23.2/28.7 34.2/40.5

448 392 344 316 268 220

490 434 386 355 301 247

HF31 HF32 HF33 HF34 HF35 HF36HF41 HF42 HF43 HF44 HF45 HF46

LCD controller: WK-110PA0Luxury wired controller: WK-010PA-K;

Ph/V/Hz 1/220-230/60 1/220-230/60 1/220-230/60 1/220-230/60 1/220-230/60 1/220-230/60

Fan Coil Unit

Thanks to optimized air flue design that greatly improve the fan efficiency and lower the operation noise.

Four directions airflow that makes an even temperature and humidity distribution.

Evaporator moisture auto clean after power off to avoid mildew.

Forced high speed fan operation under emergency condition.

Washable filter

Quiet function

Multi fan speed

Compact design

Item DB (℃) WB (℃) Inlet (℃) Outlet (℃)

Cooling 27 19 7 12

Heating 21 — 60 —

Nominal test condition (temperature)

Anti-cold function

Self-diagnosis

Cassette Type

3/4(inner groove)3/4(outer groove)

ModelHigh CFMMedium CFMLow CFM

PaCooling kW

Heating kW

TypeInput WWater flow volume l/s

kPa

Ft·WGdB(A)

Water inlet & outlet inchCondensed water drain inch

Outline mmPackage mm

kg

40'GP —40'HQ —

———

Power system

Capacity

ESP

Air flow volume

Connection pipe diameter

Sound pressure level

Pressure dropWater system

Plenum without filterPlenum with filterWired remote controller

Optionals

Loading quantity

Net weight/Gross weight

Dimension(W×D×H)

FP 170WAT R FP 204WAT R FP 238WAT R FP 272WAT R FP 306WAT R FP 340WAT R948 1043 1400 1600 1800 2000836 786 970 1235 1006 1400645 754 729 867 674 81230 30 30 30 30 30

9.65 10.96 12.35 13.49 15.67 16.537 8.85 12.97 14.165 16.46 17.36

174 212 380 475 535 6400.50 0.52 0.59 0.65 0.80 0.84 28 29.4 21.8 26.6 42.1 46.4

9.3 9.8 7.3 8.9 14.0 15.5 51 52 56 58 60 61

1921×510×245 1671×595×354 1921×595×3541940×560×275

1921×510×2451940×560×275 1750×650×380

1671×595×3541750×650×380 1950×650×380

1921×595×3541950×650×380

37.5/44 37.5/44 52/60 52/60 59/66 59/66

196 196 140 140 130 130220 220 166 166 153 153

HF37 HF37 HF28 HF28 HF29 HF29HF47 HF47 HF48 HF48 HF49 HF49

LCD controller: WK-110PA0Luxury wired controller: WK-010PA-K;

Ph/V/Hz 1/220-230/60 1/220-230/60 1/220-230/60 1/220-230/60 1/220-230/60 1/220-230/60

3/4(inner groove)3/4(outer groove)

ModelCFM

kWkW

Wl/s

kPa

Ft·WGdB(A)

inch

mm

mmmm

mm

mmkg

kg

——

——

Ph/V/Hz

FP 85XD/B T FP 102XD/B T FP 125XD/B T FP 140XD/B T FP 160XD/B T FP 180XD/B T FP 200XD/B T500/375/303 600/464/362 735/606/538 841/802/705 965/853/781 1060/1035/932 1176/9945/860

4.64 5.40 6.70 7.74 8.70 9.60 13.00 7.50 9.10 10.50 11.20 12.90 14.60 19.00

100 100 150 140 150 180 2000.23 0.26 0.33 0.38 0.43 0.47 0.6415 19 21 21 31 36 37

5.025 6.365 7.035 7.035 10.385 12.060 12.395 46 46 47 48 53 54 58

33 33 33 33 33 33 33

OutlinePackage

27/35 27/35 27/35 33/42 33/42 33/42 33/42OutlinePackage

7/11 7/11 7/11 7/11 7/11 7/11 7/11

132 132 132 112 112 112 112148 148 148 120 120 120 120

YB1FA(X-FAN) YB1FA(X-FAN) YB1FA(X-FAN) YB1FA(X-FAN) YB1FA(X-FAN) YB1FA(X-FAN) YB1FA(X-FAN)Z4E351B Z4E351B Z4E351B Z4E351B Z4E351B Z4E351B Z4E351B

Standard controller Wireless remoteOptional controller Wired remote

PanelDimension 950×950×85

1030×1035×118950×950×85

1030×1035×118950×950×85

1030×1035×118950×950×85

1030×1035×118950×950×85

1030×1035×118950×950×85

1030×1035×118950×950×85

1030×1035×118Net weight/Gross weight

Loading quantity

40'GP40'HQ

BodyDimension(W×D×H)

(W×D×H)

840×840×240 840×840×320960×960×310

840×840×240960×960×310

840×840×240960×960×310 960×960×394

840×840×320960×960×394

840×840×320960×960×394

840×840×320960×960×394

Net weight/Gross weight

Water system Water flow volumePressure drop

Sound pressure level

Connection pipe size

Water inlet & outletCondensed water drain

CapacityCoolingHeating

Power system Type 1/220-240/60 1/220-240/60 1/220-240/60 1/220-240/60 1/220-240/60 1/220-240/60 1/220-240/60Input

H/M/LAir flow volume

3/4 3/4 3/4 3/4 3/4 3/4 3/4

Built-in drain pump

TERM

INAL

TERMINALTER

MIN

AL

Page 26: Gree   catalogo completo linha comercial 2012

COMMERCIALAIR CONDITIONERS

50COMMERCIAL AIR CONDITIONERS

49

Thanks to optimized airflow design that greatly improve the fan efficiency and lower the operation noise.

The fan will be operated only if the water inlet temperature is lower than the setting value to avoid warm air under cooling condition.

Item DB (℃) WB (℃) Inlet (℃) Outlet (℃)

Cooling 27 19 7 12

Heating 21 — 60 —

Nominal test condition (temperature)

Auto clean

ModelCFMkWkW

Wl/s

kPa

Ft·WGdB(A)

inchinch

mmmm

kg

——

——

Ph/V/Hz

FP 34ZD/B T FP 51ZD/B T FP 68ZD/B T FP 85ZD/B T FP 102ZD/B T FP 136ZD/B T FP 170ZD/B T FP 204ZD/B TH/M/L 200/146/125 300/232/155 400/291/194 500/375/250 600/464/309 800/644/429 1000/750/500 1200/926/618

Cooling 1.9 2.8 3.6 4.5 5.4 7.2 9 10.8

Heating 2.8 4.15 5.4 6.75 8.1 10.8 13.5 16.2

TypeInput 40 40 62 77 99 162 240 275Water flow volume 0.10 0.14 0.18 0.23 0.26 0.37 0.42 0.55

9.8 15 36.5 36.5 30.8 34.8 38.4 42.8

3.21 4.92 11.97 11.97 10.10 11.41 12.60 14.04 48 48 49 49 49 51 52 55

Water inlet & outletCondensed water drain

Outline Package

26/35 26/35 34/38 34/38 34/38 48.5/57 48.5/57 48.5/57

40'GP 224 224 220 220 220 111 111 111

40'HQ 267 267 244 244 244 117 117 117

Air flow volume

Capacity

Wired remote

Power system1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60 1/208-230/60

Water systemPressure drop

Sound pressure level

Connection pipe diameter

1300×188×600 1590×238×695Dimension(W×D×H)

Net weight/Gross weight

Loading quantity

Wireless remote YB1FA(X-FAN)Z4E351B

YB1FA(X-FAN)Z4E351B

YB1FA(X-FAN)Z4E351B

YB1FA(X-FAN)Z4E351B

YB1FA(X-FAN)Z4E351B

YB1FA(X-FAN)Z4E351B

YB1FA(X-FAN)Z4E351B

YB1FA(X-FAN)Z4E351B

1414×248×7241300×188×6001414×248×724

1300×188×6001414×248×724 1714×330×830

1590×238×6951714×330×830

1590×238×6951714×330×830

834×238×695960×330×830

834×238×695960×330×830

3/4(outer groove)3/4(outer groove)

Optionals controller Sandard controller

Fan Coil Unit

Floor Ceiling Type

Inner groove copper

Washable filter

Quiet function

Multi fan speed

Compact design

Anti-cold function

Inner groove copper

Washable filter

Quiet function

Multi fan speed

Compact design

Anti-cold function

Self-diagnosis

Fan Coil Unit

Thanks to optimized air flue design that greatly improve the fan efficiency and lower the operation noise.

Reasonable airflow that makes an even temperature and humidity distribution.

Item DB (℃) WB (℃) Inlet (℃) Outlet (℃)

Cooling 27 19 7 12

Heating 21 — 60 —

Nominal test condition (temperature)

Auto clean

Wall Mounted Type

ModelCFMCFMCFM

kWkW

W

kPa

Ft·WGdB(A)

inch

mm

mm

mm

kg

———

Ph/V/Hz

(W×D×H)

FP 34BA2/B D FP 51BA2/B D FP 68BA2/B D FP 85BA2/B D FP 102BA2/B DHigh 212 324 400 500 588Medium 189 242 347 416 493 Low 166 215 312 362 423

Cooling 2.10 2.70 3.60 4.20 5.40 Heating 3.15 4.05 5.40 6.30 8.50 Type 1/208-230/601/208-230/601/208-230/601/208-230/601/208-230/60Input 50 50 60 60 70Water flow volume l/s 0.11 0.13 0.18 0.22 0.25

13 24 44 45 63

4.3 7.9 14.5 14.8 20.7 35 40 43 48 49

Water inlet & outletCondensing water drain 15.6 15.6 15.6 15.6 15.6

Outline 845×180×275 845×180×275 940×200×298 940×200×298 940×200×298Package 915×255×355 915×255×355 1010×285×380 1010×285×380 1010×285×380

11/14 11/14 13/17 13/17 13/17

40'GP 765 765 595 595 59540'HQ 850 850 671 671 671

Standard wireless remote controller YB1FA(X-FAN) YB1FA(X-FAN) YB1FA(X-FAN) YB1FA(X-FAN) YB1FA(X-FAN)

Net weight/Gross weight

Loading quantity

Air flow volume

Capacity

Power system

Water systemPressure drop

Sound pressure level

Connection pipe size

Dimension

1/2 1/2 1/2 1/2 1/2

TERMINALTER

MIN

AL

Page 27: Gree   catalogo completo linha comercial 2012

COMMERCIALAIR CONDITIONERS

52COMMERCIAL AIR CONDITIONERS

51

Anti-freeze designed cooling coil.

Anti-corrosion thanks to painted double-faced electro-galvanized or hot-electro-galvanized metal case.

Easy maintenance thanks to detachable panel and adjustable motor base.

Blue hydrophilic aluminum fin: The fin is anti-corrosion and easy to clean, lower decreasing of performance after years of operation.

Anti-frostcrack design for heat exchanger: With proper designed water discharge valve, complete water discharging is ensured, so that the copper tube will not be frost cracked during winter.

The heat exchange stream is well optimized design, that the heat exchange performance of the heat exchanger can be maximum utilized.

Slimmer body by maximum optimized design, can save more space and bring down the cost.

Easier maintainability

G 1.5WD(I)(Y)/B H G 2WD(I)(Y)/B H G 2.5WD(I)(Y)/B H G 3WD(I)(Y)/B H G 4WD(I)(Y)/B HG 1.5WD(I)(Y)/B F G 2WD(I)(Y)/B F G 2.5WD(I)(Y)/B F G 3WD(I)(Y)/B F G 4WD(I)(Y)/B F

m3/h 1500 2000 2500 3000 4000

CFM 881 1174 1468 1761 2348

Cooling kW 8.40/12.03 11.03/13.50 14.10/18.42 17.11/21.53 22.50/28.78

Heating kW 13.70/17.28 17.96/19.58 22.27/27.02 27.80/30.13 34.55/42.79

l/s 0.41/0.57 0.53/0.65 0.67/0.88 0.86/1.03 1.08/1.38

GPM 1.80/2.51 2.33/2.86 2.95/3.87 3.78/4.53 4.75/6.07

kPa 5/7 7/10 8/11 11/15 13/16Ft·WG 1.67/2.34 2.34 2.67 3.67 4.34

kPa 40-300 40-300 50-350 50-350 65-350Ft·WG 0.16-1.2 0.16-1.2 0.2-1.4 0.2-1.4 0.26-1.4

kg 103/140 138/150 146/160 167/180 186/200

kg 130/170 173/185 186/200 207/220 236/250

dB(A) 53 55 56 58 59

Water inlet & outlet inch DN40 DN40 DN40 DN40 DN40Condensed water drain inch DN25 DN25 DN25 DN25 DN25Outline mm 1100×1020×440 1100×1020×460 1400×1120×460 1600×1120×460

Package mm 1280×1130×595 1280×1230×615 1580×1230×615 1780×1230×615

2000×1120×460

2180×1230×615

40'GP/40'HQ — 54/54 54/54 44/44 44/44 18/18

Model

Air flow volume

Gross weight (4/6rows)

Sound pressure level

Loading quantity

Dimension (W×D×H)

Connection pipe size

Water flow volume (4/6rows)

Pressure drop (4/6rows)

Net weight (4/6rows)

Esp.range (optional )

Capacity(4/6rows)

m3/h

CFM

Cooling kW

Heating kW

l/s

GPM

kPa

Ft·WG

kPa

Ft·WG

kg

kg

dB(A)

Water inlet & outlet inch

Condensed water drain inch

Outline mm

Package mm

40'GP/40'HQ —

Model

Air flow volume

Gross weight(4/6rows)

Sound pressure level

Loading quantity

Dimension (W×D×H)

Connection pipe size

Water flow volume(4/6rows)

Pressure drop(4/6rows)

Net weight(4/6rows)

Esp.range (optional )

Capacity(4/6rows)

G 5WD(I)(Y)/B H G 6WD(I)(Y)/B H G 7WD(I)(Y)/B H G 8WD(I)(Y)/B HG 5WD(I)(Y)/B F G 6WD(I)(Y)/B F G 7WD(I)(Y)/B F G 8WD(I)(Y)/B F

5000 6000 7000 8000

2935 3522 4109 4696

28.69/36.19 33.47/43.52 39.04/53.22 44.62/59.70

43.40/53.90 52.70/63.40 62.80/77.17 66.80/87.56

1.37/1.73 1.68/2.08 2.01/2.54 2.33/2.85

6.03/7.61 7.39/9.15 8.84/11.18 10.25/12.54

16/19 16/21 17/21 18/22

5.34/6.35 5.28/6.95 5.68/7.01 6.01/7.35

65 350 75 400 75 400 90 450

0.26 1.4 0.3 1.6 0.3 1.6 0.36 1.8

235/250 235/250 280/300 325/350

290/305 290/305 340/360 390/415

60 60 61 63

DN50 DN50 DN50 DN50

DN25 DN25 DN25 DN25

2100×1320×5602280×1430×715

2100×1320×5602280×1430×715

2100×1320×5602280×1430×715

2300×1320×6602480×1430×815

18/18 18/18 18/18 18/18

Anti-corrosion and cold bridges prevention thanks to sandwich structure case.

Anti-corrosion thanks to painted double-faced electro-galvanized or hot-electro-galvanized metal case.

Painted electro-galvanized metal sheet as outer-layer.

Hot galvanized metal sheet as inner-layer.

High-density heat-insulated urethane foam filled between outer and inner layers.

Easy maintenance thanks to detachable panel and adjustable motor base.

Note:Total fresh air unit is optional.

Note:Total fresh air unit is optional.

Air Handling Unit

It is a kind of fan coil unit that is connected to the chillers to realize cooling/heating for civil or industrial use.

Horizontal Mounted Packaged

Return air typeCooling

Heating

Cooling

Heating

27 19.5 7 12

21 — 60 —

Nominal test condition (temperature)

Item Inlet (。C) Outlet (

。C)

Fresh air type35 28 7 12

7 — 60 —

Air Handling Unit

It is a kind of fan coil unit that is connected to the chillers to realize cooling/heating for civil or industrial use.Vertical Mounted Packaged

27 19.5 7 12

21 — 60 —

Nominal test condition (temperature)

Item DB (℃) WB (℃) Inlet (℃) Outlet (℃)

35 28 7 12

7 — 60 —

Return air typeCooling

Heating

Cooling

HeatingFresh air type

Washable filter

Quiet function

Easier maintainability

Compact design

Washable filter

Quiet function

Compact design

WB (。C)DB (

。C)

TERMINALTER

MIN

AL

Page 28: Gree   catalogo completo linha comercial 2012

DB (℃) WB (℃) Inlet (℃) Outlet (℃)

Cooling 27 19.5 7 12

Heating 21 — 60 —

Nominal test condition (temperature)

Item

Note:1. The specification is base on 100% return air. 100% fresh air model is also available for the same range.2. The power input of motor is subjected to the external static pressure, please refer to the brand for the accurate value.

COMMERCIALAIR CONDITIONERS

54COMMERCIAL AIR CONDITIONERS

53

G 3(I)(Y) H G 4(I)(Y) H G 5(I)(Y) H G 6(I)(Y) H G 8(I)(Y) H G 10(I)(Y) H G 12(I)(Y) HG 3(I)(Y) F G 4(I)(Y) F G 5(I)(Y) F G 6(I)(Y) F G 8(I)(Y) F G 10(I)(Y) F G 12(I)(Y) F

m3/h 3000 4000 5000 6000 8000 10000 12000CFM 1761 2348 2935 3522 4696 5870 7044

Cooling kW 18.2/26.5 23.5/35.1 32.2/44.1 36.4/52.5 48.5/66.1 60.1/84.1 72.1/96.5Heating kW 28.2/35.3 40.2/46.5 50.2/58.4 58.2/68.9 75.8/88.8 92.3/122.3 112.8/133.5

l/s 0.87/1.27 1.13/1.68 1.54/2.10 1.74/2.51 2.32/3.16 2.87/4.02 3.44/4.61GPM 3.83/3.588 4.97/7.39 6.78/9.24 7.66/11.04 10.21/13.90 12.63/17.69 15.14/20.28kPa 9.15/12.9 11.9/14.6 16.0/15.0 21.2/16.1 30.9/20.8 57.1/23.2 12.0/15.6

Ft·WG 3.06/4.31 3.97/4.88 5.34/5.01 7.08/5.38 10.32/6.95 19.07/7.75 4.01/8.55kPa 50-300 65-350 65-350 75-350 90-450 90-500 100-500

Ft·WG 0.2-1.2 0.26-1.4 0.2-1.4 0.3-1.4 0.36-1.8 0.36-2.0 0.4-2.0kg 215/240 260/295 305/330 340/375 390/435 450/485 503/535kg 250/275 295/335 345/360 420/455 430/475 475/535 563/585

dB(A) 56 56 57 58 59 59 61Water inlet & outlet inch DN40 DN40 DN50 DN65 DN65 DN65 DN65Condensed water drain inch DN25 DN25 DN25 DN25 DN40 DN40 DN40Outline mm 1150×730×1300 1350×830×1400 1350×830×1600 1750×830×1800Package mm 1260×830×1420

1150×730×1400

1260×830×1520 1450×930×1520 1450×930×1720 1880×948×1920

1950×830×1800

2070×948×1920

1950×830×1900

2070×948×202040'GP 22 22 16 14 12 12 12

40'HQ —

22 22 16 14 12 12 12

Net weight(4/6rows)

Esp.range (optional )

Gross weight(4/6rows)

Model

Air flow volume

Capacity(4/6rows)

Water flow volume(4/6rows)

Pressure drop(4/6rows)

Sound pressure level

Loading quantity

Connection pipe size

Dimension (W×D×H)

m3/h

CFM

Cooling kW

Heating kW

l/s

GPM

kPa

Ft·WG

kPa

Ft·WG

kg

kg

dB(A)

Water inlet & outlet inch

Condensed water drain inch

Outline mm

Package mm

40'GP

40'HQ —

Net weight(4/6rows)

Esp.range (optional )

Gross weight(4/6rows)

Model

Air flow volume

Capacity(4/6rows)

Water flow volume(4/6rows)

Pressure drop(4/6rows)

Sound pressure level

Loading quantity

Connection pipe size

Dimension (W×D×H)

G 14(I)(Y) H G 16(I)(Y) H G 18(I)(Y) H G 20(I)(Y) H G 22(I)(Y) H G 25(I)(Y) H G 30(I)(Y) HG 14(I)(Y) F G 16(I)(Y) F G 18(I)(Y) F G 20(I)(Y) F G 22(I)(Y) F G 25(I)(Y) F G 30(I)(Y) F

14000 16000 18000 20000 22000 25000 30000

8218 9392 10566 11740 12914 14675 17610

82.1/111.6 91.1/123 106.2/143.8 121.5/168 133.5/179 152.3/195 175.5/233

129.5/155.4 143.3/173.2 161.5/198.2 178.4/224 207.2/245.6 226.3/278.5 271.4/335

3.92/5.34 4.35/5.88 5.07/6.87 5.81/7.89 6.38/8.56 7.28/9.32 8.39/11.14

17.25/23.50 19.14/25.87 22.31/30.23 25.56/34.72 28.07/37.66 32.03/41.01 36.92/49.02

22.1/28.0 23.0/32.1 25.0/35.2 25.0/38.5 20.0/32.1 29.0/36.0 23.0/38.0

7.36/9.36 7.68/10.72 8.35/11.78 8.35/12.86 6.68/10.72 9.69/12.02 7.68/12.69

100 550 120 600 120 650 140 700 170 750 170 750 220 800

0.42.2 0.48 2.4 0.48 2.6 0.56 2.8 0.68 3.0 0.68 3.0 0.44 3.2

545/580 745/780 790/840 815/860 865/915 910/960 1015/1250

590/630 820/850 850/900 890/930 905/980 950/1000 1075/131063.5 63.5 65.5 67 68 68 71

DN65 DN65 DN65 DN80 DN80 DN80 DN80

DN40 DN40 DN40 DN40 DN40 DN40 DN40

2250×930×2100

2338×1048×2230

2250×930×2100

2338×1048×2230

2250×930×2100

2338×1048×2230

1950×1440×1930

2040×1500×2060

2250×1640×2030

2340×1700×2160

2250×1640×2030

2340×1700×2160

2250×1640×2330

2340×1700×24608 8 8 7 5 5 4

8 8 8 7 5 5 4

Air Handling Unit

Cold bridge preventing design: The AHU adopts anodized aluminum alloy with high anti-corrosion performance, hard PVC as cold bridge, soft PVC as seal packing ring and beading, of which insulation performance is higher. Double skin panel with polyurethane foam insulation, which is lighter and lower heat conductivity factor.

Modular design: All the function sections of the AHU are of modular design,which can be matched randomly to satisfy various of requirements.

High airtightness design: The AHU adopts special rubber material as seal packing ring and buckle aluminum extruded sections, with extreme low air leakage rate.

Computer software selection: AHU selection software is available to make computer selection according to need.

It is a kind of air handling unit that the function section could be chosen customized according to various project requirements.

Hydronic Air Handling Unit

Easier maintainability

Compact design

Washable filter

Quiet function

TERMINALTER

MIN

AL

Page 29: Gree   catalogo completo linha comercial 2012

COMMERCIALAIR CONDITIONERS

56COMMERCIAL AIR CONDITIONERS

55

Diffuser

Adjustable grille

Square diffuser Return air grille

B

A

CCBB

A

BB

A

HH

HHHH

11

HH

Airflow directionFilter

Return air grille Adjustable grilleSquare diffuser

Installation Dimension

Square dif fuser

A HThroat B

FKDB45 60448×448

FKDB60 598×598 60

FKDB6325

FKDB10025

630×253 685×308 28

1005×260 1034×290 30

25

A C H H1

FKFS45 270×270

FKFS60 368×368

448x448

517x517

375x375

598x598

365

485

25

27 34

A H

FKSB6312

FKSB10012

630×120 180

160120

690× 50

1000× 1040× 50

Throat B

Throat B

Return air grille

Adjustable grille

Model

Model

Model

Single Deflection Return Air Grille The single-layer louver air inlet is equipped with filter which is detachable and mountable.

Adjustable Double Deflection Grille The dual-layer grille type air outlet can adjust the airflow to each corner.

The diffuser is applicable to various constructions for its combination of square and round types. It is with good appearance, strong air pressure,low noise, even airflow distribution and long distribution distance, etc.

Air-suction section(fresh air/return air)

Air-suction section(secondary air

-returning section)

Mixing section

Primary filtratingsection

(plate type/bag type)

Primary filtratingsection

(plate type/bag type)

Sub high-efficiencyfiltrating section

High-efficiencyfiltrating section

Name Sketch Name Sketch Name Sketch Name Sketch

Cooling coilsection

Electrical heatingsection

Heating coilsection

Steam coilsection

Electrodehumidifying

section

Contact humidifyingsection

Dry steamhumidifying

section

Fan section

Complex section(combination

sections of exhaust,air-returning

and fresh air sections)

Air equalizingsection

Sound absorbersection

Service section(maintenance

section)Turning section

Blowing section

Optionl Funtion Section

Spec. Cooling capacity under air return condition

Cooling capacity under fresh air condition Air supply total pressure

GZK W(mm) H(mm) Unit 2(m/s) 2.25(m/s) 2.5(m/s) 2.75(m/s) 3(m/s) kW kW Pa

CFM

CFM

CFM

CFM

CFM

CFM

CFM

CFM

CFM

CFM

CFM

CFM

Section dimension Airflow volume against air velocity

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

CFM

CFM

CFM

CFM

CFM

m3/h

m3/h

m3/h

m3/h

m3/h

1241 1396 1552 1707 1862

729 820 911 1003 10942172 2444 2715 2987 3258

1276 1435 1595 1754 1914

3103 3491 3879 4267 4655

1823 2051 2278 2506 2734

4109 4622 5136 5650 6163

2414 2715 3017 3319 3620

5115 5754 6393 7033 7672

3004 3380 3756 4131 4507

7126 8017 8908 9799 10690

4186 4709 5233 5756 6279

5342 6009 6677 7345 8012

3138 3530 3922 4314 4707

6649 7480 8311 9143 9974

3906 4394 4882 5371 5859

9186 10334 11482 12631 13779

5396 6070 6745 7419 8094

12278 13813 15347 16882 18417

7212 8114 9015 9917 10819

8936 10053 11170 12287 13404

5249 5906 6562 7218 7874

12405 13956 15507 17057 18608

7287 8198 9109 10020 10931

15750 17719 19687 21656 23625

9252 10408 11565 12721 13878

16566 18637 20708 22779 24850

9731 10948 12164 13381 14597

18907 21270 23634 25997 28361

11106 12495 13883 15271 16660

21248 23904 26560 29216 31872

12481 14042 15602 17162 18722

26133 29399 32665.86 35932 39199

15351 17270 19189 21107 23026

0804

0806

850

850

850

1050

0808

1008

1050

1250

450

650

850

850

1050

1250

1650

2050

1250

1650

850

850

1050

1050

1050

1250

1250

1250

1650

1650

2012

1616

1650

2050

1650

1208

1608

1010

1210

1212

1612

1610

2010

1650

20502050

1816

2016

2020

1850

2050

6-14

10-24

15-35

20-44

25-56

36-81

25-57

53-95 400~1200

60-136

80-164

81-182

400~1200

400~1500

400~1500

400~1500

99-210

32-72

46-104

62-127

41-93

17-28

94-162

69-124

86-151

111-195

400~1200

29-50 400~1200

41-71 400~1200

66-116 400~1200

114-222

139-273

122-209 400~1500

147-254 400~1500

191-329 400~1500

213-366 400~1500

159-274 400~1500

317-547 400~2000

222-422 400~1500

258-445 400~1500

TERMINALTER

MIN

AL

Page 30: Gree   catalogo completo linha comercial 2012

MARINE AIR CONDITIONER

COMMERCIALAIR CONDITIONERS

58COMMERCIAL AIR CONDITIONERS

57

SPECIALIZED

AC

SPECIALIZED

AIR CONDITIONER

Page 31: Gree   catalogo completo linha comercial 2012

Marine Air Conditioner

360 degree air blowing.

Outlay electric box for easy installation & maintenance.

Low start-up current thanks to power delay control design.

Forced operation available for emergency situation.

LCD display of operation status.

Highly anti-corrosion special spray processing on the complete unit.

Nickel-copper tube-in-tube heat exchanger for sea water side.

All-copper fined tube heat exchanger for air side.

Only one PCB for the entire control and minimize cable connections, with higher reliability and also easier maintenance.

COMMERCIALAIR CONDITIONERS

60COMMERCIAL AIR CONDITIONERS

59

Model CYR5/NaB T CYR9/NaB T CYR12/NaB T CYR16/NaB TW 1650 2600 3500 4500

Btu/h 5630 8870 11900 15360

W 1750 2650 3800 4750

Btu/h 5970 9050 13000 16200

W/W 3.06/3.24 3.10/3.15 3.18/3.45 3.60/3.80

Ph/V/Hz 1/230/60 1/230/60 1/230/60 1/230/60

Cooling kW 0.54 0.84 1.1 1.25

Heating kW 0.54 0.84 1.1 1.25

Cooling A 2.4 3.7 4.6 5.6

Heating A 2.4 3.7 5 5.6

dB(A) 58 58 58 58

kg 0.35 0.34 0.55 0.66

m3/h 330 470 550 720

CFM 194 276 324 424

Outline mm 309×440×324 409×458×370

Package mm 547×540×404

411×457×324

672×617×308 647×568×450

478×488×365

701×607×445

Kg 25/30 28/33 34/39 35/40.5

inch 3.07 3.07 2.99 3.61

inch 0.63 0.87 0.87 0.87

40'GP 552 576 312 345

40'HQ 644 648 390 414

Fan motor supply air outlet diameter

Net weight/Gross weight

EER/COP

Dimension(W×D×H)

Loading quantity

Capacity

Power supply

Sound pressure level

Air flow volume

Power input

Input current

Refrigerant charge volume

Cooling

Heating

Condenser pipe diameter

Heat pump

__

__

Washable filter

℃/℉ SwitchMemory function

Model Heat pumpW

Btu/h

W

Btu/h

W/W

Ph/V/Hz

Cooling kW

Heating kW

Cooling A

Heating A

dB(A)

kg

m3/h

CFM

Outline mm

Package mm

Kg

inch

inch

40'GP

40'HQ

Fan motor supply air outlet diameter

Net weight/Gross weight

EER/COP

Dimension(W×D×H)

Loading quantity

Capacity

Power supply

Sound pressure level

Air flow volume

Power input

Input current

Refrigerant charge volume

Condenser pipe diameter

CYR5/NaB A CYR9/NaB A CYR12/NaB A CYR16/NaB A1600 2600 3500 4400

5460 8874 11946 15017

1750 2800 3800 4750

5973 9556 12969 16212

2.90/3.50 3.02/3.33 3.15/3.02 3.03/3.47

1/115/60 1/115/60 1/115/60 1/115/60

0.55 0.86 1.11 1.45

0.5 0.84 1.26 1.37

4.7 7.7 9.7 11.7

4.5 7.3 10.9 11

58 58 58 58

0.35 0.45 0.55 0.66

350 470 450 700

205 276 264 412

295×428×295

478×528×277.5

390×435×295

574×531×279

390×448×330

574×556×291.5

460×480×330

641×568×293.5

24/29 28/33 34/39 35/40

3.07 3.07 2.99 3.61

0.87 0.87 0.87 1

768 704 672 576

864 792 756 648

Cooling

Heating

__

__

It is a kind of sea water source AC that is widely used in yachts and boats.

Display panelZ5A35

Compact design

Golden fincondenser

Inner groovecopper

Self-diagnosisQuiet function

SPECIALIZED AIR CONDITIONERSPEC

IALIZED AC

Page 32: Gree   catalogo completo linha comercial 2012

COMMERCIAL AIR CONDITIONERS

61

CONTROL SYSTEM LINEUP

GMV CONTROL SYSTEM

GREE LONG-DISTANCE CONTROL SYSTEM & BMS INTERFACE

Control SYSTEMS

COMMERCIALAIR CONDITIONERS

62

CO

NTR

OL SYSTEM

S

Page 33: Gree   catalogo completo linha comercial 2012

COMMERCIALAIR CONDITIONERS

64COMMERCIAL AIR CONDITIONERS

63

Duct type

Wireless remote controller

Wired remote controller

Long-distancemonitoring software

BMS accessories

Centralized controller

Other modules

Product series

Control system

Cassette type Wall-mounted type

Floor ceiling type

Air handler type

Communicationmodule

(modbus)

Communication module(modbus)

only applicable to DCinverter 600&900

Gree ACEudemon 2009*

GMV BACet gateway(BACnet)

Group controller(mini centralized

controller)

Centralizedcontroller*(modbus)

Smart zone controller

Key-card controlboard

Optoelectronic isolatedconverter

Optoelectronic isolatedsignal multiplier

Y512

YB1FA

Z60351F(Heat/Cool)

Z60151F(Cool)

Z63351F(Heat/Cool)

Z63151F(Cool)

ZX60451

JS02(Reseiver)

FE30-00/A(M)

ME30-00/E2

ME30-24/E2(M)

MG30-24/D1(B)

ZJA011

CE51-24/E(M)

CE50-24/E

MK03

RS232-RS422/485

RS-422/485

Note:● means standard, ● means optional.* If centralized controller CE51-24/E(M) or long-distance monitoring software Gree Eudemon 2009 is selected, the communication module ME30-00/E2 shall be selected also.

The quantity of the module should be confirmed according the quantity of the outdoor unit.

Wireless remote controller

Wired remote controller

Long-distancemonitoring software

U-Match

Duct type Cassette type Floor ceiling type

YB1F2

Z4E351A

FE30-00/A(M)

ME30-00/E2BMS accessories

Centralizedcontroller

Other modules

ZJ4011AWeekly centralized

controller

Communication module

(modbus)

Gree AC Eudemon 2009

Smart zone controller

Optoelectronic isolated

converter

Optoelectronicisolated signal

multiplier

CE50-24/E

RS232-RS422/485

RS-422/485

Note:● means standard, ● means optional.

Duct split unit

Product series

Control system

CONTROL SYSTEM LINEUPC

ON

TRO

L SYSTEMS

Unitary GMV

Page 34: Gree   catalogo completo linha comercial 2012

COMMERCIALAIR CONDITIONERS

66COMMERCIAL AIR CONDITIONERS

65

Note:● means standard, ● means optional.

Control system

Air-cooled scrow chillerProduct series

Display panel

Air-cooled scroll chiller (C series)

Long-distancemonitoring software

Other modules

Gree ACEudemon 2009

Communicationmodule

Optoelectronic isolatedconverter

Optoelectronic isolatedsignal multiplier

Z26301C

Z2F11E*

FE30-00/A(M)

ME30-28/E (M)

RS232-RS422/485

RS-422/485

Product series

Wireless remote controlier

Wired remote controlier

Digital thermostat

Long-distancemonitoring software

BMS accessories(modbus)

BMS accessories(modbus)

Other modules

YB1FA

Gree ACEudemon 2009

Communication module

(modbus)

Optoelectronicisolated converter

Optoelectronic isolated

signal multiplier

Y512

Z4E351B

Luxury

FE30-00/A(M )

ME30-17/E2(M)

RS232-RS422/485

RS-422/485

WK-110PA0

Note:● means standard, ● means optional.* If long-distance monitoring software Gree Eudemon 2009 is selected, the communication module ME30-17/E2(M) shall be selected also.

The quantity of the module should be confirmed according the quantity of the outdoor unit.

Wall mounted type

Concealed ceiling type

Control system

Floor ceilingtype

4-way cassette type

* With BMS (modbus) function.

CONTROL SYSTEM LINEUPC

ON

TRO

L SYSTEMS

Chiller

Terminal

Page 35: Gree   catalogo completo linha comercial 2012

COMMERCIAL AIR CONDITIONERS

67

GMV System Air Conditioning

Individual Control Air ConditioningCentral Control Buiding Management

Module link

Transmission line (GMV network)

Group controller line

Remote controller line

Modbus network

BACnet network

IR receiver line

Key-card control board line

Key-card signal line

IR Receiver UnitJS01

Group ControllerZJA011

Wired Remote ControllerZ63351F/Z63151FZ60351F/Z60151F

Centrallzed ControllerCE51-24/E(M)

BMS Interface (Modbus)ME 30-00/E2

MS Interface (BACnet)MG30-24/D1(B)

Smart Zone ControllerCE50-24/E

Web Monitoring Client

RS-422/485 Repeater

Communlcatlon Module

RS-232 to RS-422/485 Converter

Gree AC Eudemon 2009 (Monitoring Software)

Web Monitoring Server

Web Monitoring Client

Building Management System

Wired Remote ControllerZX60451

ME30-00/E2

ME30-00/E2

ME30-00/E2

ME30-00/E2

FE30-00/A(M)

MK03 (Field supplied)

Y512YB1FA

Wireless Remote Controller

Key-card Control Board

Key-card

Note:Control network sketch is for reference only,please refer to the equipment manuals for actual cable connection method.

COMMERCIALAIR CONDITIONERS

68

GMV CONTROL SYSTEMC

ON

TRO

L SYSTEMS

Page 36: Gree   catalogo completo linha comercial 2012

COMMERCIALAIR CONDITIONERS

70COMMERCIAL AIR CONDITIONERS

69

GREE LONG-DISTANCE CONTROL SYSTEM & BMS INTERFACE

Wiring CommunicationModule

CommunicationModule

CommunicationModule

GMV Unit GMV Unit

GMV Unit

CommunicationModule

CommunicationModule

CommunicationModule

Scroll Chiller

Scroll Chiller

CommunicationModule

Water-cooled ScrewChiller

Water-cooled ScrewChiller

CommunicationModule

CommunicationModule

Centrifugal Chiller

Centrifugal Chiller

Other GreeAC Unit

Communication Module

Max16 Max16 Max16

Max16

Max8

Elevator

VentilationGMV Unit

Scroll Chiller

CommunicationModule

CommunicationModule

Air-cooled ScrewChiller

Air-cooled ScrewChiller

CommunicationModule

CommunicationModule

Centrifugal Chiller

Fire Protection

Lighting

BMS of User

PC&Software

Gree ACEudemon 2009

Communication

Converter

Max16

Max

255

Max

255

Max

255

Max16

Max16

Max8

CO

NTR

OL SYSTEM

S