grazing incidence spectrometer

4
McPherson, 7-A Stuart Road, Chelmsford MA 01824-4107 USA | Telephone 1-978-256-4512 | www.McPhersonInc.com Soft Xray & EUV Monochromator & Spectrograph 1m grazing incidence spectrometer with AndorTechnology DOseries CCD for directdetection, great performance, and flexibility in the soft xray and extreme UV wavelength range. The spectrometer scans and positions the CCD detector to simplify and speed up data acquisition. Features Benefits CCD compatibility for spectrograph operation Fast, easy data acquisition of spectral data in the soft xray, extreme and vacuum UV Grazing Incidence Angles, 84 to 88 degrees Various angles available to tailor reflectivity and range to the application High vacuum operation Internally welded, clean construction with Viton™ seals for 10E6 torr. UHV (10E10 torr) available* Kinematic grating mount Easy to change kinematic single grating holder High performance drive system Precision curved way and drive for guaranteed reproducibility, RS232 and USB included SXR, EUV and VUV gratings available A variety of diffraction gratings are available delivering best efficiency for your application Compact built in vacuum isolation valve (optional) Vacuum valve simplifies integration with experimental systems Compact built in filter mount (optional) Filters (Al metal film, for example) reject long wave VUV and Visible light * call or email to consult; we can quote the instrument setup that best meets your needs

Upload: erik-schoeffel

Post on 01-Apr-2016

241 views

Category:

Documents


5 download

DESCRIPTION

McPherson 1m focal length Rowland circle spectrometer for soft x-ray (SXR) and extreme ultraviolet (EUV) spectroscopy. Fast acquisition with direct detection CCD and micro channel plate intensified detection systems.

TRANSCRIPT

 

McPherson, 7-A Stuart Road, Chelmsford MA 01824-4107 USA | Telephone 1-978-256-4512 | www.McPhersonInc.com

 

Soft X‐ray & EUV Monochromator & Spectrograph 

 1m grazing incidence spectrometer with Andor‐Technology DO‐series CCD for direct‐detection, great performance, and flexibility in the soft x‐ray and extreme UV wavelength range. The spectrometer scans and positions the CCD detector to simplify and speed up data acquisition. 

 

 

 

Features  Benefits

CCD compatibility for spectrograph operation Fast, easy data acquisition of spectral data in the

soft x‐ray, extreme and vacuum UV 

Grazing Incidence Angles, 84 to 88 degrees Various angles available to tailor reflectivity and 

range to the application 

High vacuum operation Internally welded, clean construction with Viton™ 

seals for 10E‐6 torr. UHV (10E‐10 torr) available* 

Kinematic grating mount  Easy to change kinematic single grating holder

High performance drive system Precision curved way and drive for guaranteed 

reproducibility, RS232 and USB included 

SXR, EUV and VUV gratings available A variety of diffraction gratings are available 

delivering best efficiency for your application 

Compact built in vacuum isolation valve (optional) Vacuum valve simplifies integration with  

experimental systems 

Compact built in filter mount (optional) Filters (Al metal film, for example) reject long 

wave VUV and Visible light 

 

* call or email to consult; we can quote the instrument setup that best meets your needs 

 

McPherson, 7-A Stuart Road, Chelmsford MA 01824-4107 USA | Telephone 1-978-256-4512 | www.McPhersonInc.com

Soft X‐ray & EUV Monochromator & Spectrograph 

 Above: Gas pinch soft x‐ray spectrum from 1m grazing‐incidence spectrometer with direct‐detection CCD  

     

Grating Selection (others available) 

 Contact  us  today  to  learn  more  about  monochromators  and  spectrographs  for  the  vacuum ultraviolet,  extreme  UV  and  soft  x‐ray  wavelength  region.  We  also  have  calibration  sources, detectors, sample chambers, collimators and telescopes for the VUV. 

SpecificationsFocal Length  998.8 mm Grazing Angle (degrees)  84 to 88 availableAperture Ratio  44 Linear Dispersion* 0.3 nm/mmResolution (fwhm)*  0.02 nm Accuracy* ±0.05 nmRepeatability*  ±0.005 nm Vacuum Range 10E‐6 torrOptical Design  Grazing Rowland Circle Focal Plane 40mm max (tangential)Scan Range*  0 – 35 nm Grating Size 25 x 20 mmGrating Mount  Kinematic single UHV Construction**  Optional 10E‐10 torrAdjustable Slits  0.01 to 0.5 mm  Optical Axis Height 195 mm (+10mm)Weight  80 kg Computer Interface  RS232 or USB*Using 1200g/mm grating with 0.01mm slit**Please inquire 

 

McPherson, 7-A Stuart Road, Chelmsford MA 01824-4107 USA | Telephone 1-978-256-4512 | www.McPhersonInc.com

SXR Spectrograph with direct detection CCD 

 

Model 248/310 one meter grazing incidence spectrometer with an Andor‐Technology DO420BN‐995 CCD:  This diagnostic instrument is mounted vertically, looking down into the XAPPER light source at Lawrence Livermore National Laboratory. The source is a “Radio‐frequency‐preionized xenon Z‐pinch source for extreme ultraviolet lithography” used for lithography, damage threshold and ablation experiments. Some typical spectra are shown below. 

  

 

Other technical papers with data from the 248/310 grazing spectrograph and DO420BN‐995 CCD: 

‐Liquid‐jet laser–plasma extreme ultraviolet sources: from droplets to filaments ‐Influence of Z‐pinch evolution on laser pulse duration at 46.9 nm in Ne‐like Ar ions  ‐The Spectrum of Ne‐Like Ar and the 4d‐4p Transition of Kr7+ at 45 nm in Capillary Discharge Experiment  ‐Debris‐free soft x‐ray generation using a liquid droplet laser‐plasma target ‐Rep‐rated X‐ray Damage and Ablation Experiments for IFE and ICF Applications ‐Effect of multi‐shot X‐ray exposures in IFE armor materials    

 

McPherson, 7-A Stuart Road, Chelmsford MA 01824-4107 USA | Telephone 1-978-256-4512 | www.McPhersonInc.com

SXR Spectrograph with Microchannel plate + CCD 

 Model 248/310 one meter grazing incidence spectrometer with microchannel plate intensifier and Andor‐Technology DH420A‐FO CCD:  The microchannel plate (MCP) mounts tangent to the Rowland circle to intercept best focus across the detector array. In addition to gain, the MCP may be gated and synchronized with signals from the experiment. The MCP is efficiently fiber coupled to the CCD. (UNM) 

Left: Images of HHG‐spectra recorded at different central wavelength positions using the McPherson grazing incidence spectrometer with MCP and Andor CCD (Max‐Planck‐Institut). Below: HHG scanning mode spectra (Friedrich‐Schiller‐University) 

 

Other technical papers with data from 248/310 grazing spectrograph with MCP and fiber coupled DH420A‐F0  ‐Photon Diagnostic for the Seeding Experiment at FLASH (Free‐electron LASer at DESY, Germany) ‐Influence of current prepulse on capillary‐discharge extreme‐ultraviolet laser ‐High‐order harmonic generation directly from a filament ‐Spatial fingerprint of quantum path interferences in high order harmonic generation ‐High harmonics from solid surfaces as a source of ultra‐bright XUV radiation for experiments ‐A Gigawatt High‐Voltage Generator for Coherent Soft X‐Ray Generation