graffiti - wall washer · 1306 doris avenue, ocean, nj 07712 usa 800.462.7812 | 732.517.0800 fax...

3
GR-W Series GR-W Series TM WALL WASHER Project Name: Specifier: Distributor: Quantity: Type: Signature: Series wallwashing in low to medium ceiling heights typically found in residential, commercial or retail applications.The wall wash fixture creates consistant and even illumination from ceiling down using our propri- etary Supertex TM lens. Fixture provided with LED positioned for optimal performance. The Graffiti TM fixtures provide cost effective LED lighting solutions. As the creative spirit of its name implies, Graffiti TM systems provide all the quality SLI has grown famous for over the last 25 years, but at re- duced lead times, affordable price points and innovative technologies that will liberate your creative flair. is the innovative new line of LED lighting solutions from Specialty Lighting Industries. 1306 Doris Avenue, Ocean, NJ 07712 USA 800.462.7812 | 732.517.0800 FAX 732.517.0971 www.specialtylightingindustries.com Patent Pending. These specifications subject to change without notice. 12/19 GRW SPECIFICATIONS THERMAL MANAGEMENT: Proprietary high performance aluminum black heatsink for maximum LED life MOUNTING - Recessed in architectural ceiling. Butterfly brackets and Hanger bars included with housing and mounting pans. RM- Open fixture for retrofit for remodel in existing ceilings IC- Housing for new construction where insulation comes in contact with fixture NIC- Housing for new construction where IC not required NP- For New construction DP- Pan for dropped ceilings BP- Pan for metal studs CP- Chicago Plenum HOUSING - C1/C2 Fixed housing is smaller size than Lutron/EldoLED Fixed housing (see page 3 for details)*. TRIM - Die cast aluminum, flanged or flangeless trim with a regress bevel and overlap for flange . Available for wet locations. Accommodates up to 1” ceiling thickness as standard. ZT- for use in plaster/GWB ceilings FT/FST- for use in architectural ceilings ELECTRICAL Standard 0-10v (C1) Dimming down to 1% TRIAC/ELV (C2) Dimming down to 1% EldoLED 0-10v (E1) Logarithmic Dimming down to 0.1% EldoLED Dali (E2) Dimming down to 0.1% EldoLED 0-10v (E3) Linear Dimming down to 0.1% Lutron Hi-lume (L2) Hi-lume 1% (former A-Series) 2-wire Driver Lutron Hi-lume EcoSystem 1% (LTB) Hi-lume 1% with Fade-to-Black (former H-Series) digital EcoSystem Driver Lutron Hi-lume Premier 0.1% (LTP) Hi-lume Premier 0.1% with Fade-to-Black digital EcoSystem EM Pack Dimming driver with emergency battery backup All drivers are field replaceable* LED CZ- Citizen 2700-4000K, 90+CRI AD- Ambient Dim TM 3000-1900K, 97 CRI XT- Xicato 2700-4000K, 90+ CRI LENS/OPTICS - Supertex borosilicate spread lens, hinged for relamping. Alzak kick reflector. FINISH - Black powder paint housing. Aper. trim available in white as standard. Can be field painted to match ceiling finish. WARRANTY - 5 year limited on LED and driver. See website for details. LABELS - , US tested to UL standards 1598, Dry/Damp and Wet listings. IC/Airtight, compliant, compliant. Chicago Plenum Available. Specifier/Installer is responsible for testing & validating compatability of any control equipment used. Additional conductors may be required depending on dimming system. 8 JA

Upload: others

Post on 15-Oct-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GRAFFITI - WALL WASHER · 1306 Doris Avenue, Ocean, NJ 07712 USA 800.462.7812 | 732.517.0800 FAX 732.517.0971 Patent Pending. These specifications subject to change without notice

G R- W SeriesG R- W Series

TM

WALL WASHER

Project Name: Specifier:Distributor: Quantity: Type:Signature:

Series wallwashing in low to medium

ceiling heights typically found in residential, commercial or

retail applications.The wall wash fixture creates consistant

and even illumination from ceiling down using our propri-

etary SupertexTM lens. Fixture provided with LED positioned

for optimal performance. The GraffitiTM fixtures provide cost

effective LED lighting solutions. As the creative spirit of its

name implies, GraffitiTM systems provide all the quality SLI

has grown famous for over the last 25 years, but at re-

duced lead times, affordable price points and innovative

technologies that will liberate your creative flair.

is the innovative new line

of LED lighting solutions from

Specialty Lighting Industries.

1306 Doris Avenue, Ocean, NJ 07712 USA 800.462.7812 | 732.517.0800 FAX 732.517.0971 www.specialtylightingindustries.com

Patent Pending. These specifications subject to change without notice. 12/19

G R W

SPECIF ICATIONS

THERMAL MANAGEMENT: Proprietary high performance aluminum black heatsink for maximum LED life

MOUNTING - Recessed in architectural ceiling. Butterfly brackets and Hanger bars included with housing and mounting pans. • RM- Open fixture for retrofit for remodel in existing ceilings• IC- Housing for new construction where insulation comes in contact with fixture• NIC- Housing for new construction where IC not required• NP- For New construction• DP- Pan for dropped ceilings• BP- Pan for metal studs• CP- Chicago Plenum

HOUSING - C1/C2 Fixed housing is smaller size than Lutron/EldoLED Fixed housing (see page 3 for details)*.

TRIM - Die cast aluminum, flanged or flangeless trim with a regress bevel and overlap for flange . Available for wet locations. Accommodates up to 1” ceiling thickness as standard.• ZT- for use in plaster/GWB ceilings• FT/FST- for use in architectural ceilings

ELECTRICAL • Standard 0-10v (C1) Dimming down to 1% • TRIAC/ELV (C2) Dimming down to 1% • EldoLED 0-10v (E1) Logarithmic Dimming down to 0.1%• EldoLED Dali (E2) Dimming down to 0.1%• EldoLED 0-10v (E3) Linear Dimming down to 0.1% • Lutron Hi-lume (L2) Hi-lume 1% (former A-Series) 2-wire Driver • Lutron Hi-lume EcoSystem 1% (LTB) Hi-lume 1% with Fade-to-Black (former H-Series) digital EcoSystem Driver • Lutron Hi-lume Premier 0.1% (LTP) Hi-lume Premier 0.1% with Fade-to-Black digital EcoSystem • EM Pack Dimming driver with emergency battery backup All drivers are field replaceable*

LED • CZ- Citizen 2700-4000K, 90+CRI • AD- Ambient DimTM 3000-1900K, 97 CRI• XT- Xicato 2700-4000K, 90+ CRI

LENS/OPTICS - Supertex borosilicate spread lens, hinged for relamping. Alzak kick reflector.

FINISH - Black powder paint housing. Aper. trim available in white as standard.Can be field painted to match ceiling finish.

WARRANTY - 5 year limited on LED and driver. See website for details.

LABELS - , US tested to UL standards 1598, Dry/Damp and Wet

listings. IC/Airtight, compliant, compliant. Chicago Plenum Available.

Specifier/Installer is responsible for testing & validating compatability of any control equipment used. Additional conductors may be required depending on dimming system.

8JA

Page 2: GRAFFITI - WALL WASHER · 1306 Doris Avenue, Ocean, NJ 07712 USA 800.462.7812 | 732.517.0800 FAX 732.517.0971 Patent Pending. These specifications subject to change without notice

1306 Doris Avenue, Ocean, NJ 07712 USA 800.462.7812 | 732.517.0800 FAX 732.517.0971 www.specialtylightingindustries.com

Patent Pending. These specifications subject to change without notice. 12/18

ORDER INFO

SQUARE / FLANGED

ROUND/ FLANGED

SQUARE / FLANGELESS

ROUND / FLANGELESS

JA824TITLE

JA824TITLE

JA824TITLE

JA824TITLE

JA824TITLE

JA824TITLE

JA824TITLE

JA824TITLE

JA824TITLE

JA824TITLE

JA824TITLE

JA824TITLE

JA824TITLE

JA824TITLE

JA824TITLE

JA824TITLE

JA824TITLE

JA824TITLE

CODE

Graffiti TM Housing

HousingRM = Retrofit*IC = ICNIC = Non ICNP = New Pan*DP = Dropped Pan*BP = Bracket Pan* * Consult factory for XicatoCP = Chicago Plenum

Source/Wattage/Lumens/DeliveredAD14 = Ambient DimTM / 14.5W / 1000lm / 475lmCZ14 = Citizen / 14W / 1640lm / 574lmCZ20 =Citizen / 20W / 2265lm / 786lmXT8 = Xicato / 8W / 800lm / 440lmXT12 = Xicato / 12W / 1055lm / 580lmXT17 = Xicato / 17W / 1400lm / 817lm

Type

WW = Wall Wash

CCT27 = 2700K30 = 3000K35 = 3500K40 = 4000KAD = 3000K-1900K

DriverC1 = 0-10V dimming, 1%, 120-277vC2 = TRIAC/ELV 2-wire, 1% 120V only (Leading/Trailing Edge) E1 = EldoLED 0-10V Logarithmic Dim, 0.1%, 120-277vE2 = EldoLED DALI, 0.1%, 120-277v E3 = EldoLED 0-10V Linear Dim, 0.1%, 120-277v L2 = Hi-lume 1% (former A-Series) 2-wire Driver, 120v only (LTEA)LTB = Hi-lume 1% with Fade-to-Black (former H-Series) digital EcoSystem Driver, 120-277v (LDE1)LTP = Hi-lume Premier 0.1% with Fade-to-Black digital EcoSystem, 120-277v (PEQ0) EM**= Emergency Pack

GraffitiTM Trim

ShapeRD = RoundSQ = Square

TrimFT = FlangedZT = FlangelessFST* = Flanged Shower

FinishWHT = White

Lens82A = Frosted Supertex

* CLICK HERE to view Accessories for Trims.

GRW

GRTW

**Lutron & EldoLED require Inverter

C1/C2 Fixed Housing is smaller size than Lutron / Eldo LED Fixed Housing (See page 3 for Details)*

PHOTOMETRICS

*Visit website for further photometric data

or Click Here

*LED Technology rapidly changes. Please consult factory for latest specs and photometry.

INFORMATION - TRIM

TM

WHT

82A

WW

Page 3: GRAFFITI - WALL WASHER · 1306 Doris Avenue, Ocean, NJ 07712 USA 800.462.7812 | 732.517.0800 FAX 732.517.0971 Patent Pending. These specifications subject to change without notice

1306 Doris Avenue, Ocean, NJ 07712 USA 800.462.7812 | 732.517.0800 FAX 732.517.0971 www.specialtylightingindustries.com

Patent Pending. These specifications subject to change without notice. 7/18

For projects requiring housings or IC rated fixtures.

RETROFIT

PAN

ROUND / PLASTER FLANGESQUARE / FLANGE

For easy installation in existing ceilings.

OPTION - New Pan

OPTION - Dropped Pan

OPTION - Bracket Pan

64 MM [2 1/2”]

316 MM [12 1/2”]

559 MM [22”]349 MM [13 3/4”] 210 MM [8 1/4”]

203 MM [8”]

631 MM [24 7/8”]592 MM [23 1/4”]

229 MM [9”]

406 MM [16”]

229 MM [9”]

For new construction applications not requiring a housing.

INFORMATION - HOUSING

13 1/2

15/32

Female

Male

1 3/8

4 1516"

[124 MM]

4 34" [120MM]

SQ CUTOUT4 5

8" [118 MM]

ILLUMINATEDWALL

3 38"

4 1516"

[124 MM]

4 34" [120MM]

SQ CUTOUT4 5

8" [118 MM]

ILLUMINATEDWALL

3 38"

4 1516"

[124 MM]

4 34" [120MM]

SQ CUTOUT4 5

8" [118 MM]

ILLUMINATEDWALL

3 38"

1" MAXCEILING

4" 34"

SQ CUTOUT

ILLUMINATEDWALL4" 5 1

2"

DRIVER ENCLOSURE

1 12"

8"

2"

3 38"

1287 Hanger Bar comes standard with Bracket Pan & IC/NICMaximum Extension: 26”

10" [254 mm]

6 58" [168 mm]8 5

8" [219 mm]

9 12" [241 mm]

4 18" [105 mm]

4 58" SQ [118 mm] CUTOUT

1" [25 mm] MAX

5 38" [137 mm] 3 1

4" [83 mm]

10" [254 mm]6 5

8" [168 mm]

4 18" [105 mm]

4 58" [118 mm] CUTOUT

1" [25 mm] MAX

8 58" [219 mm]

9 12" [241 mm]

5 38" [137 mm] 3 1

4[83 mm]

"

1287 Hanger Bars comes standard with fixed and adjustable housing (see below for hanger bar dimensions).

9" [229 MM]

4 58"

[117 MM]

4 34" [120 MM]

SQ CUTOUT

14 12" [368 MM]

13" [330 MM]

3 12"

[89 MM]

1" [25 MM]MAX

4 12"

[114 MM]10" [254 MM] 4 12"

[114 MM]4 1

2"[114 MM]

IC NIC

CP

/

/

for use in Armstrong®T-Bar ceilings

FIXED C1/C2 Drivers FIXED LUTRON / ELDO Drivers

34" [19 mm]