Rethinking Gas AnalyticsGPro 500 TDL Series
![Page 2: GPro 500 Leporello - Elscolab · GPro 500 Leporello Author: Mettler-Toledo AG Subject: First Release: 01/2014 Created Date: 2/3/2014 1:33:13 PM](https://reader030.vdocuments.mx/reader030/viewer/2022041117/5f2d98780331d8085b61b962/html5/thumbnails/2.jpg)
Looking for the accuracy and reliability of a TDL, without the hassle of the optics alignment?
![Page 3: GPro 500 Leporello - Elscolab · GPro 500 Leporello Author: Mettler-Toledo AG Subject: First Release: 01/2014 Created Date: 2/3/2014 1:33:13 PM](https://reader030.vdocuments.mx/reader030/viewer/2022041117/5f2d98780331d8085b61b962/html5/thumbnails/3.jpg)
Look no more. The first compact probe-style TDL for process applications: GPro 500 with standard purged probe
• One flange only, no alignment required• Convenience of a sensor, power of an analyzer• A breakthrough innovation from METTLER TOLEDO
METTLER TOLEDO GPro 500 Q & A Guide 3
Innovative Value Solution | The GPro 500 TDL
![Page 4: GPro 500 Leporello - Elscolab · GPro 500 Leporello Author: Mettler-Toledo AG Subject: First Release: 01/2014 Created Date: 2/3/2014 1:33:13 PM](https://reader030.vdocuments.mx/reader030/viewer/2022041117/5f2d98780331d8085b61b962/html5/thumbnails/4.jpg)
Drift-free in-situ TDL measurements with static inertization conditions: not possible?
![Page 5: GPro 500 Leporello - Elscolab · GPro 500 Leporello Author: Mettler-Toledo AG Subject: First Release: 01/2014 Created Date: 2/3/2014 1:33:13 PM](https://reader030.vdocuments.mx/reader030/viewer/2022041117/5f2d98780331d8085b61b962/html5/thumbnails/5.jpg)
METTLER TOLEDO GPro 500 Q & A Guide 5
Yes, it is. The first probe-style TDL without process side purging:GPro 500 with “non-purged” probe
• No process side purging necessary• Suitable for static, dry and clean gases• Fast response time and no long-term drift
Unique Application Expansion | Non-Purged Probe
![Page 6: GPro 500 Leporello - Elscolab · GPro 500 Leporello Author: Mettler-Toledo AG Subject: First Release: 01/2014 Created Date: 2/3/2014 1:33:13 PM](https://reader030.vdocuments.mx/reader030/viewer/2022041117/5f2d98780331d8085b61b962/html5/thumbnails/6.jpg)
You want the superior performance of a TDL in dust-loaded combustion applica-tions, without the expensive purge?
![Page 7: GPro 500 Leporello - Elscolab · GPro 500 Leporello Author: Mettler-Toledo AG Subject: First Release: 01/2014 Created Date: 2/3/2014 1:33:13 PM](https://reader030.vdocuments.mx/reader030/viewer/2022041117/5f2d98780331d8085b61b962/html5/thumbnails/7.jpg)
METTLER TOLEDO GPro 500 Q & A Guide 7
Certainly. The first probe-style TDL for high-dust environments: GPro 500 with non-purged probe with filter tip
• Ideal for combustion applications• Insensitive to high dust loads• Several filter pore sizes available
Unique Non-Purged Probe | For Dusty Processes
![Page 8: GPro 500 Leporello - Elscolab · GPro 500 Leporello Author: Mettler-Toledo AG Subject: First Release: 01/2014 Created Date: 2/3/2014 1:33:13 PM](https://reader030.vdocuments.mx/reader030/viewer/2022041117/5f2d98780331d8085b61b962/html5/thumbnails/8.jpg)
You need the reliability of a TDL everywhere in your process applications, even in the smallest pipes?
![Page 9: GPro 500 Leporello - Elscolab · GPro 500 Leporello Author: Mettler-Toledo AG Subject: First Release: 01/2014 Created Date: 2/3/2014 1:33:13 PM](https://reader030.vdocuments.mx/reader030/viewer/2022041117/5f2d98780331d8085b61b962/html5/thumbnails/9.jpg)
METTLER TOLEDO GPro 500 Q & A Guide 9
Of course. The only TDL for measurement in pipes down to DN50 (2"):GPro 500 with wafer adaption
• High-accuracy measurement in small pipes• No flow obstruction• Purge gas, temperature and pressure ports
Unique Wafer TDL | For Pipe Installation
![Page 10: GPro 500 Leporello - Elscolab · GPro 500 Leporello Author: Mettler-Toledo AG Subject: First Release: 01/2014 Created Date: 2/3/2014 1:33:13 PM](https://reader030.vdocuments.mx/reader030/viewer/2022041117/5f2d98780331d8085b61b962/html5/thumbnails/10.jpg)
Interested in deploying TDL technology, but without throwing away your sampling system?
![Page 11: GPro 500 Leporello - Elscolab · GPro 500 Leporello Author: Mettler-Toledo AG Subject: First Release: 01/2014 Created Date: 2/3/2014 1:33:13 PM](https://reader030.vdocuments.mx/reader030/viewer/2022041117/5f2d98780331d8085b61b962/html5/thumbnails/11.jpg)
METTLER TOLEDO GPro 500 Q & A Guide 11
Here’s the solution. The only TDL that retrofits to your extractive analyzer:GPro 500 with on-line adaption
• Flow-through chamber with ATEX and FM integrity• Suitable for corrosive gases• Convenient handling and low maintenance
Make it Easy | Simply Retrofit with Extractive TDL
![Page 12: GPro 500 Leporello - Elscolab · GPro 500 Leporello Author: Mettler-Toledo AG Subject: First Release: 01/2014 Created Date: 2/3/2014 1:33:13 PM](https://reader030.vdocuments.mx/reader030/viewer/2022041117/5f2d98780331d8085b61b962/html5/thumbnails/12.jpg)
GPro 500The Game Changers
A unique set of process adaptions for in-situ and on-line TDL measurements. www.mt.com/gas
No alignment
No purge
DN50 pipes
High dustOn-line
• Oxygen• CO• H2O