gossamer cove redwood city, ca illustrated preliminary defect list

78
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Slide 1 GOSSAMER COVE Redwood City, CA Illustrated Preliminary Defect List Presented By: R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 3550 Camino Del Rio North, Suite 305 San Diego, CA 92108 (619) 624-9272 FAX (619) 624-9566 www.rhadcock.com

Upload: george-guthrie

Post on 31-Dec-2015

55 views

Category:

Documents


2 download

DESCRIPTION

Presented By: R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 3550 Camino Del Rio North, Suite 305 San Diego, CA 92108 (619) 624-9272 FAX (619) 624-9566 www.rhadcock.com. GOSSAMER COVE Redwood City, CA Illustrated Preliminary Defect List. Overall. Overall. 1.0 ROOFS Composition Shingle. - PowerPoint PPT Presentation

TRANSCRIPT

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.Slide 1

GOSSAMER COVE Redwood City, CA

Illustrated Preliminary Defect ListPresented By:

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

3550 Camino Del Rio North, Suite 305

San Diego, CA 92108

(619) 624-9272

FAX (619) 624-9566

www.rhadcock.com

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Overall

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Overall

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

1.0 ROOFS Composition Shingle

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Degradation and tears in composition shingles.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Leaks at complex intersections of roof.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Shingle installed upside down.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Metal flashing laps not sealed.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Headwall flashing nailed through.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Discontinuous edge metal at outside corners.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Gaps in flashing.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Cracked shadow board.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Gutter system lifting shingles at eave.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Penetration flashings not set in mastic.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Penetration flashings not set in mastic.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

2.0 BALCONIES

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Balcony Overall

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Balcony waterproofing system failure; staining and water intrusion.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Ponding at balcony/inadequate slope.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

5.0 EXTERIOR SIDING AND TRIM

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Exterior siding fasteners popping and overdriven.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Exterior siding fasteners popping and overdriven.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Missing sealant at joints in siding.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Voids at penetrations.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Water table flashing nailed through.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Damaged siding installed.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Exterior light fixture not sealed.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Gaps and separation at wood trim.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Gaps and separation at wood trim.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Improper flashing termination at brick veneer; exposed building paper.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Garage door wood trim in contact with concrete.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

8.0 EXTERIOR DOORS

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

French door threshold failure; stained tack strip and missing sealant.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

French door sticking/racked.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Failed glazing strips at door exterior; leaking sealant.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Improper door weather strip; gaps.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

9.0 CONCRETE

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Concrete slab failure at garages/ponding and spalling.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Concrete flatwork failure at driveway; cracking.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Efflorescence at slab.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Driveway with reverse slope to garage/ponding.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Driveway slab with vertical displacement.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

11.0 WALLBOARD

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Drywall system failure; cracking.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Drywall system failure; cracking.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Wallboard cracks at doors.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Window sill and jamb drywall cracking.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

14.0 SUB-FLOORS

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Floor sheathing is improperly fastened; floor squeaks.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

15.0 MISCELLANEOUS ARCHITECTURAL

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Failure of rigid grout at counter tops to backsplash in kitchens; cracking.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Kitchen ceramic tile failure; cracking.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Laundry room ceramic tile failure; cracking.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Bathroom overall.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Bathroom vanity ceramic tile failure; cracking.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Bathtub/fiberglass panel joint failure; leaking.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Inadequately supported bathtub.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Vinyl flooring lifting in front of tub.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Shower enclosure failure; stained.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Shower enclosure failure; stained tack strip carpet.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Shower pan/ceramic tile joint without flexible grout.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Attic access inadequate; less than 30"x 30".

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

16.0 VINYL WINDOWS

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Window Overall

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Window system failure; staining.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Window system failure; staining.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Window system failure; staining.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Vinyl window damaged during installation.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Fogged dual pane window.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Window installed out of square.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

17.0 ELECTRICAL

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Ground wires not attached.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

GFI circuit overload easily tripped.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

19.0 PLUMBING

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Slab interior leak; requires further investigation.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Improper attachment of toilet.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

Plumbing leak at gas water heater.

R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC.

The End