global calibration gases llc - welcome to the … · global calibration gases llc 1090 commerce...

26
Global Calibration Gases LLC 1090 Commerce Blvd N Sarasota, FL 34243 www.globalcalibrationgases.com ISO 17025:2005 Accredited For Calibration and Testing PGVP: N22016

Upload: duongtram

Post on 21-Apr-2018

219 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

Global Calibration Gases LLC1090 Commerce Blvd N

Sarasota, FL 34243www.globalcalibrationgases.com

ISO 17025:2005 Accredited

For Calibration and Testing

PGVP: N22016

Page 2: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

GLOBAL CALIBRATION GASES IS A

WORLD CLASS MANUFACTURER OF

PRECISION CALIBRATION GAS

STANDARDS AND CUSTOM GAS

MIXTURES. WE OFFER OUR PRODUCTS

BOTH DOMESTICALLY AND

INTERNATIONALLY THROUGH A

NETWORK OF AUTHORIZED

DISTRIBUTORS SELECTED BASED ON

THEIR EXTENSIVE KNOWLEDGE OF THE

PRODUCTS AND THEIR APPLICATIONS,

AND MOST IMPORTANTLY, THE

CUSTOMERS THEY SERVE.

Page 3: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

AUTHORIZED DISTRIBUTORS

IN THE USA AND CANADA: THROUGH A

NETWORK OF INDEPENDENT WELDING

SUPPLY DISYRIBUTORS THAT BELONG TO

IWDC (INDEPENDENT WELDING

DISTRIBUTOR CO-OP) AND OTHER

SELECT DISTRIBUTOR BUYING GROUPS

IN LATIN AND SOUTH AMERICA:

THROUGH GLOBAL SYSTEMS LLC

IN EUROPE AND THE MIDDLE EAST:

THROUGH AGT INTERNATIONAL

IN ASIA AND AUSTRALIA: THROUGH

SCIENTIFIC GASES CORP

Page 4: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

PROUDLY SERVING

POWER PLANTS MANUFACTURING FIBRE OPTICS FOOD & BEVERAGE

NATURAL GAS SEMICONDUCTOR PHARMACEUTICALS AIR QUALITY

PULP & PAPER RESEARCH PETROCHEMICALS WATER QUALITY

Page 5: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

EXTENSIVE CYLINDER PREPARATION TECHNOLOGY

EXCLUSIVE TO GLOBAL CALIBRATION GASES LLC

CYL-INERT® IS A PROPRIATERY ALUMINUM CYLINDER TREATMENTT PROCESS PERFECTED

OVER 40 YEARS OF SERVICE. THIS TREATMENT GUARANTEES THE LONG TERM STABILITY

OF LOW CONCENTRATION REACTIVE GAS MIXTURES. THIS STABILITY IS ESSENTIAL TO MEET

THE EXTENDED SHELF LIFE REQUIREMETS OF EPA PROTOCOL GAS MIXTURES. CYL-INERT® IS

A REGISTERED TRADEMARK OF SPECIAL GAS SERVICES INC.

Page 6: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

GAS BLENDING TECHNOLOGY

STATE OF THE ART BLENDING STATIONS DEDICATED TO INDIVIDUAL GAS SERVICES ARE

COUPLED WITH THE MOST ADVANCED GRAVIMETRIC CAPABILITIES IN THE INDUSTRY. SCALES

ARE CHECKED FOR ACCURACY AGAINST NIST TRACEABLE CLASS 1 WEIGHTS CERTIFIED

ANNUALLY BY AN INDEPENDENT ISO17025 NVLAP ACCREDITED METROLOGY INSTITUTE TO

ECHELON 1 STANDARDS. GRAVIMETRIC METHODOLOGY IS IN STRICT ACCORDANCE WITH

ISO 6142.

Page 7: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

ANALYTICAL CAPABILITIES

NON-DISPERSIVE INFRARED

FLAME IONIZATION

THERMAL CONDUCTIVITY

CHEMILUMINESCENCE

ELECTROCHEMICAL

ELECTROLYTIC

MICRO-TCD/GC TECHNOLOGY

PULSED DID GC TEHNOLOGY

PHOTO-IONIZATION

Page 8: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

ISO/IEC 17025:2005 ACCREDITATION

CALIBRATION

Page 9: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

ISO/IEC 17025:2005 ACCREDITATION

TESTING

Page 10: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

OUR CORE COMPETENCY

EPA Protocol Gas Mixtures

The EPA Protocol

(EPA-600/R-97/121 September 1997)

EPA Traceability Protocol for Assay and

Certification of Gaseous Calibration Standards

Acid Rain Requirements

Appendices A and B to 40 Code of Federal Regulations (CFR)

Part 75 which describe

specification and test procedures for continuous emissions

monitors including daily

calibration tests and periodic accuracy tests (RATA).

40 CFR 1065.750 Analytical gases

GLOBAL CALIBRATION GASES LLC: PGVP ID # N22016

Page 11: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

2012 Revision of EPA

Traceability Protocol

EPA 600/R-12/531 May 2012

Publication in June 2012 with recent

technical corrections

Specialty gas producers have one

year to implement the changes

New website for protocol, Excel

spreadsheets, Q&A compilation

http://www.epa.gov/nrmrl/appcd/m

md/db-traceability-protocol.html

Page 12: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

EPA 600/R-12/531 May 2012

This is a 174

page document

and is referred to as

“The Green Book”

Page 13: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

The Changes Were Dramatic and Costly to Producers

1) Expiration dating was changed to more closely resemble

the shelf life of the SRMs available.

2) Statistical requirements supporting the accuracy of the

analyses were drastically tightened-Students t Test vs. TOST

(Schuirmann’s two one-sided tests).

3) The regulated community must use EPA Protocol Gases from

PGVP vendors.

4) Protocol Gases in the field may be re-certified to the new

expiration periods.

Page 14: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

The AA-PGVP QA requirements in 40 CFR Part 58, Appendix A require:

"2.6 Gaseous and Flow Rate Audit Standards. Gaseous pollutant

concentration standards (permeation devices or cylinders of compressed gas)

used to obtain test concentrations for CO, SO2, NO, and NO2 must be

traceable to either a National Institute of Standards and Technology (NIST)

Traceable Reference Material (NTRM), NIST Standard Reference Materials

(SRM) and Netherlands Measurement Institute (NMi) Primary Reference

Materials (valid as covered by Joint Declaration of Equivalence) or a NIST-

certified Gas Manufacturer's Internal Standard (GMIS), certified in accordance

with one of the procedures given in reference 4 of this appendix. Vendors

advertising certification with the procedures provided in reference 4 of this

appendix and distributing gases as 'EPA Protocol Gas' must participate.

PGVP Ambient Audit

(EPA Region 2 & 7)

Page 15: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

"On and after May 27, 2011 for each unit subject to this

part that uses EPA Protocol gases, the owner or operator

must obtain such gases from either an EPA Protocol gas

production site that is on the EPA list of sites

participating in the PGVP on the date the owner or

operator procures such gases or from a reseller that sells

to the owner or operator unaltered EPA Protocol gases

produced by an EPA Protocol gas production site that

was on the EPA list of participating sites on the date the

reseller procured such gases."

PGVP Source Level Audit

(Blind Audit)

Page 16: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

Most Recent Audit Results

Carbon Monoxide -0.39% Nitric Oxide -0.31% Sulfur Dioxide +0.22%

A maximum bias of 2.0% Is Allowable and Acceptable

Carbon Monoxide

EPA Protocol Gas Verification Program Date of Assay: 16-Dec-14

Cylinder under Test: Global

EB0028036

Pollutant Gas: Carbon Monoxide

Balance Gas: Nitrogen

Cylinder Pressure After Assay: 1990psig

Assayed CO Concentration = 2981.24

Vendor Certified CO

Concentration = 2993

% bias = -0.39%

95% uncertainty of analysis = 0.38%

Reference Gas: SRM 2639a

CAL016818

Expiration Date: 18-Jan-16

Analyst: Avi Teitz/Mustafa Mustafa

Analytical

Facility: EPA Region 2 Ambient Air Standards

Laboratory, Edison, NJ

Oxides Of Nitrogen

EPA Protocol Gas Verification Program

Date of Assay: 15-Dec-14

Cylinder under Test: Global

EB0057743

Pollutant Gas: Nitric Oxide

Balance Gas: Nitrogen

Cylinder Pressure After Assay: 1900psig

Assayed NO Concentration = 50.37

Vendor Certified NO Concentration = 50.21

% bias = 0.31%

95% Uncertainty of Analysis = 0.27%

Assayed NOx Concentration = 50.44

Vendor Certified NOx Concentration = 50.59

% bias = -0.29%

95% Uncertainty of Analysis = 0.13%

Reference Gas: SRM 1683b

CAL015158

Expiration

Date: 1-Jun-16

Analyst: Avi Teitz/Mustafa Mustafa

Analytical Facility: EPA Region 2 Ambient Air Standards Laboratory,

Edison, NJ

Sulfur Dioxide

EPA Protocol Gas Verification

Program Date of Assay: 11-Dec-14

Cylinder under Test: Global

EB0057732

Pollutant Gas: Sulfur Dioxide

Balance Gas: Nitrogen

Cylinder Pressure After

Assay: 1925psig

Assayed SO2 Concentration = 50.41

Vendor Certified SO2

Concentration = 50.30

% bias = 0.22%

95% uncertainty of analysis = 0.20%

Reference Gas: SRM 1693a

CAL015159

Expiration Date: 1-Jun-16

Analyst: Avi Teitz/Mustafa Mustafa

Analytical

Facility: EPA Region 2 Ambient Air Standards

Laboratory, Edison, NJ

Page 17: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

17

Global

NO

/No

x

EPA Protocol Gas Verification Program

Date of Assay: 15-Dec-15

Cylinder under Test: Global

EB0052185

Pollutant Gas: Nitric Oxide

Balance Gas: Nitrogen

Cylinder Pressure After Assay: 1950psig

Assayed NO Concentration = 50.80

Vendor Certified NO Concentration = 50.10

% bias = 1.41%

95% Uncertainty of Analysis = 0.77%

Assayed NOx Concentration = 50.15

Vendor Certified NOx Concentration = 50.40

% bias = -0.49%

95% Uncertainty of Analysis = 0.68%

Reference Gas: SRM 1683b

CAL015158

Expiration

Date: 1-Jun-16

Analyst: Avi Teitz/Mustafa Mustafa

Analytical Facility:

EPA Region 2 Ambient Air Standards Laboratory, Edison, NJ

Page 18: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

18

Global

SO2

EPA Protocol Gas Verification Program

Date of Assay: 10-Dec-15

Cylinder under Test: Global

EB0028920

Pollutant Gas: Sulfur Dioxide

Balance Gas: Nitrogen

Cylinder Pressure After Assay: 1950psig

Assayed SO2 Concentration = 50.47

Vendor Certified SO2 Concentration = 50.50

% bias = -0.06%

95% uncertainty of analysis = 0.25%

Reference Gas: SRM 1693a

CAL015159

Expiration Date: 1-Jun-16

Analyst: Avi Teitz/Mustafa Mustafa

Analytical Facility:

EPA Region 2 Ambient Air Standards Laboratory, Edison, NJ

Page 19: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

19

Global

CO

EPA Protocol Gas Verification Program

Date of Assay: 17-Dec-15

Cylinder under Test: Global

EB0068037

Pollutant Gas: Carbon Monoxide

Balance Gas: Nitrogen

Cylinder Pressure After Assay: 1950psig

Assayed CO Concentration = 2965.08252

Vendor Certified CO Concentration = 2975

% bias = -0.33%

95% uncertainty of analysis = 0.51%

Reference Gas: SRM 2639a

CAL016818

Expiration Date: 18-Jan-16

Analyst: Avi Teitz/Mustafa Mustafa

Analytical Facility:

EPA Region 2 Ambient Air Standards Laboratory, Edison, NJ

Page 20: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

NIST RESEARCH GAS MATERIALS

Bias = 0.002%

Absolute

Bias = 0.003%

Absolute

Page 21: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

Customers under EPA regulations CFR 40 part 60

and part 75 use these mixtures as well as stack

testing professionals performing CFR 40 Part 60

Appendix A analyzer method compliance sampling,

namely Methods 3A, 6C, 7E, 10A, 320, and 321.

The most common Protocols produced are:

Oxygen (O2)

Carbon Dioxide (CO2)

Carbon Monoxide (CO)

Nitrogen Oxides (NOx)

Sulfur Dioxide (SO2)

Propane (C3H8)

Methane (CH4)

Page 22: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

EPA Method Method Requirements

Page 23: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

40 CFR 1065.750 Analytical gases

(ii) Table 1 of §1065.750—General specifications for purified gases

Constituent Purified synthetic air1 Purified N21

THC (C1equivalent) ≤ 0.05 µmol/mol ≤ 0.05 µmol/mol.

CO ≤ 1 µmol/mol ≤ 1 µmol/mol.

CO2 ≤ 10 µmol/mol ≤ 10 µmol/mol.

O2 0.205 to 0.215 mol/mol ≤ 2 µmol/mol.

NOX ≤ 0.02 µmol/mol ≤ 0.02 µmol/mol.

N2O2 ≤ 0.05 µmol/mol ≤ 0.05 µmol/mol.

(i) FID fuel . Use FID fuel with a stated H2concentration of (0.39 to 0.41) mol/mol,

balance He, and a stated total hydrocarbon concentration of 0.05 µmol/mol or less.

Page 24: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

Additional CapabilitiesNIST Traceable Primary Standards per ISO 6142

BTU (Natural Gas) Standards including hexanes+, nonane, decane,

undecane and dodecane

Multi-component BTEX mixtures (including O, M, and P-Xylene)

Multi-component sulfur gas standards including COS, CS2,

and C1-C4 mercaptans

Multi-component gas phase hydrocarbon blends through C12

Multi-component VOC standards

Low ppm DID standards

Low ppm Moisture standards

Low ppm oxygen standards traceable to VSL

Rare Gas laser blends (Excluding Excimer Laser Blends)

Page 25: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

What we do not do (but would like to)

Pure hydrocarbons for re-sale

Liquid hydrocarbon blends

Piston cylinder blends

TO 14/15/17 blends

BAR 97 blends

Grade 6.0 helium, argon, and nitrogen

Grade 5.0 helium, argon, and nitrogen

Semiconductor dopant blends

6000 psi filling

Excimer laser blends

Page 26: Global Calibration Gases LLC - Welcome to the … · Global Calibration Gases LLC 1090 Commerce Blvd N ... PGVP: N22016. GLOBAL CALIBRATION GASES IS A ... 95% uncertainty of analysis

Coming Soon!

The Specialty Gas Institute

Hosted by:

Global Calibration Gases