glast lat project page 1 acd installation, post lat cdr response to glast lat cdr rfa number 13:...

5
GLAST LAT Project Page 1 ACD Installation, Post LAT CDR ACD Installation, Post LAT CDR Response to GLAST LAT CDR RFA Number 13: MGSE Detailed Dimension Study [for ACD Installation] A) Perform detailed dimension study. Crane hook height appears inadequate for installation of ACD See slides 3 and 4 B) Provide information on the clean room entrances and clearances that will exist when equipment (including GSE) is brought in and out. Large, Double Door to Class 100K Crane Room is 111” [ 2,819 mm ] wide by 108” [ 2,743 mm ] high Small, Single Door to Class 100K Clean Room is 59” [ 1,499 mm ] wide by 79” [ 2,007 mm ] high The LAT on the Integration Stand, the Low Profile ACD Integration Stand and the 8’ x 8’ x 6.2’ tall ACD Dolly fits in Rm 104; See slide 5 March 08, 2004

Upload: hector-wiggins

Post on 19-Jan-2016

222 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GLAST LAT Project Page 1 ACD Installation, Post LAT CDR Response to GLAST LAT CDR RFA Number 13: MGSE Detailed Dimension Study [for ACD Installation] –A)

GLAST LAT Project

Page 1

ACD Installation, Post LAT CDRACD Installation, Post LAT CDR

• Response to GLAST LAT CDR RFA Number 13: MGSE Detailed Dimension Study [for ACD Installation]– A) Perform detailed dimension study. Crane hook height

appears inadequate for installation of ACD• See slides 3 and 4

– B) Provide information on the clean room entrances and clearances that will exist when equipment (including GSE) is brought in and out.• Large, Double Door to Class 100K Crane Room is 111” [ 2,819 mm ]

wide by 108” [ 2,743 mm ] high

• Small, Single Door to Class 100K Clean Room is 59” [ 1,499 mm ] wide by 79” [ 2,007 mm ] high

• The LAT on the Integration Stand, the Low Profile ACD Integration Stand and the 8’ x 8’ x 6.2’ tall ACD Dolly fits in Rm 104; See slide 5

March 08, 2004

Page 2: GLAST LAT Project Page 1 ACD Installation, Post LAT CDR Response to GLAST LAT CDR RFA Number 13: MGSE Detailed Dimension Study [for ACD Installation] –A)

GLAST LAT Project

Page 2

ACD Installation, Post CDR ConceptACD Installation, Post CDR Concept

• SLAC will develop a low profile integration stand• When ready for ACD mate operations, the LAT will be lifted

from the Rotation / Support Stand and set onto the low profile stand

• Next slide shows available clearances• The “available clearances” assume an 8” [ 203 mm ] high

spreader– Current welded joint analyses indicate that the spreader

needs to be at least 8” high (i.e., Rectangular Structural Steel Tubing that is also 6” wide and 0.375” thick)

– 13.6” [ 345 mm ] of room to operate crane along Z (vertical)

March 08, 2004

Page 3: GLAST LAT Project Page 1 ACD Installation, Post LAT CDR Response to GLAST LAT CDR RFA Number 13: MGSE Detailed Dimension Study [for ACD Installation] –A)

GLAST LAT Project

Page 3

LAT With ACD To / From Rotation StandLAT With ACD To / From Rotation Stand

• Crane load block maximum height is 134 inches [ 3,403 mm ] (Hook removed)

• No problem moving LAT to / from integration stand

• 13.6” [ 345 mm ] Operable Height for Crane, with Scale in the loop

¾” OTS 316 CRES Turnbuckles Rated for 5,200 lbs each

6.0”[ 152.4 mm ]

53.0”[ 1,346 mm ]

120.4”[ 3,058 mm ]

ACD Installed

21.2” [ 538

mm ]

Crane Lift Block attaches directly to Crane Scale that

attaches directly to Lift Spreader Post

8,856 lbs

Crane Load Block

March 25, 2004

Page 4: GLAST LAT Project Page 1 ACD Installation, Post LAT CDR Response to GLAST LAT CDR RFA Number 13: MGSE Detailed Dimension Study [for ACD Installation] –A)

GLAST LAT Project

Page 4

ACD Installation, Low Profile Integration StandACD Installation, Low Profile Integration Stand

49.3”[ 1,253 mm ]

6.0”[ 153 mm ]

Crane Lift Block at high point

134”[ 3,403 mm ]

124”[ 3,150 mm ]

Low Profile ACD Integration Stand

ACD

LAT 4x4 Lift Spreader, 8” [203 mm] High

Working Hook Height 10” [ 254 mm ]

March 25, 2004

96.9”[ 2,461 mm ]

TKRs

18.0”[ 457 mm ]

4” [ 102 mm ]

Page 5: GLAST LAT Project Page 1 ACD Installation, Post LAT CDR Response to GLAST LAT CDR RFA Number 13: MGSE Detailed Dimension Study [for ACD Installation] –A)

GLAST LAT Project

Page 5

LAT With ACD To / From Rotation StandLAT With ACD To / From Rotation Stand

ACD Low Profile

Integration Stand ACD on

8’ by 8’ Dolly

• All Required Hardware for ACD Integration Fits in Room

• ACD Low Profile Integration Stand and its Dolly are within Crane’s Pick Zone

• ACD on Dolly easily fits through Double Doors ( LAT May require bagging during door opening events)

Integration Stand is Placed to Allow Range

of Motion for PAPs

March 08, 2004