gl-sp15 series users’ manual caution - glaciallight · users’ manual gl-sp15 series 1. the...

2
Users’ Manual GL-SP15 Series 1. The warranty period will last for two years since you buy the products. If the product fails or malfunctions under the proper installation and normal usage within the warranty period, please send it back to our company with our RMA approval or contact your local distributors for free repairing or replacing services. 2. Please do not add/remove any electrical components to/from the products or change/tamper the original electrical design without our permission. 3. Please do not add/remove any mechanical components to/from the products or change/tamper the original mechanical design without our permission. 4. lease store or use the products in an environment meeting the temperature and humidity conditions designated by the product specifications. Please do not uncover the GL-SP15 series LED products, lest waterproof and dustproof become invalid. 5. To avoid any electrical shock or functional damage, please do not insert any foreign objects into the products. 6. For further information, please contact us. CAUTION Best Position GL-SP15 100V-240V~ 50-60Hz Thank you for choosing the GL-SP15 series LED products. Please install and use the products according to the following directions to ensure the normal function and proper operation of the products. If not to follow these instructions to properly install and normally use the products, you will not get the warranty-committed compensation or protection. GlacialLight will not take any responsibility for any product damage caused by improper installation or abnormal usage. 1. Before installation, please turn off the power switch for the existing lamp. 2. Please make sure that both the AC voltage source and the power connector are compatible with the GL-SP15 series LED products. • Pick a vantage point based on the directions of human and car traffic • Install the sensor at a location within 10 ~ 15 meter radius of the vantage point, 2.5 ~ 3 meter high and at an angel of adjustable sensor is up / down 10° ~ 30° (best at 90 degree) • Make sure the sensor is firmly screwed Worst sensing effects (Straightline moving forward) Insufficent range due to low sensing angle Short sensing range and prone to false detections due to high sensing angle 4. Please insulate properly the wires/terminals of the AC voltage source, screw tightly the GL-SP15 series LED products onto a wall or a stand, and adjust freely the lighting angle in accordance with individual needs. 5. Please turn on the AC voltage source to check whether the GL-SP15 series LED products can work normally. If not, please check carefully whether all the above installation steps are taken and usage conditions are met. Installation Steps Indicators on the bottom of the sensors 1. SENS: The intensity of sensing. + indicates strong sensing. - indicates weak sensing. 2. LUX: The brightness of the environment. Moon mark (>3 lux) indicates night sensing; effective when human entering the sensing area in low illuminations. Please avoid strong light resource because it may lead sensor to false detections. Sun Mark indicates 24-hour sensing regardless day or night. It is effective. 3. TIME: The light up time of sensing. From 7 seconds to 12 minutes. SENS LUX TIME 10 m 15 m (Lateral Moving) Best sensing effects , Longest sensing range 2.5 m 3 m 3 m Installation height and sensing angle are proper ~ ~ 10 m ~ 15 m 3 ~ 5 m 90° ~ 100° 30° ~ 35° Ground wire green AC wire (N) white or blue AC wire (L) black or brown AC wire (L) black or brown AC wire (N) white or blue Ground wire green 3. The GL-SP15 series LED products feed only on an AC voltage source having an appropriate output voltage designated by the product specifications. Please connect respectively the Brown, Blue, and Green/yellow wires/terminals at the rear side of the GL-SP15 series LED products to the Line (L), Neutral (N), and Frame Ground (FG) wires/terminals of the AC voltage source. It depends on the model in use that the Brown, Blue, and Green/Yellow wires may be not screwed or screwed internally onto a terminal block. Misusing an inappropriate voltage source may lead to product damage. CAUTION CLASS 2 LED LIGHT Do not stare at the beam. Installation procedure should be undertaken by qualified technical personnel.

Upload: nguyenque

Post on 08-Nov-2018

226 views

Category:

Documents


0 download

TRANSCRIPT

Users’ ManualGL-SP15 Series

1. The warranty period will last for two years since you buy the products. If the product fails or malfunctions under the proper installation and normal usage within the warranty period, please send it back to our company with our RMA approval or contact your local distributors for free repairing or replacing services.

2. Please do not add/remove any electrical components to/from the products or change/tamper the original electrical design without our permission.3. Please do not add/remove any mechanical components to/from the products or change/tamper the original mechanical design without our permission.4. lease store or use the products in an environment meeting the temperature and humidity conditions designated by the product specifications. Please do not

uncover the GL-SP15 series LED products, lest waterproof and dustproof become invalid.5. To avoid any electrical shock or functional damage, please do not insert any foreign objects into the products.6. For further information, please contact us.

CAUTION

Best Position

GL-SP15100V-240V~ 50-60Hz

Thank you for choosing the GL-SP15 series LED products. Please install and use the products according to the following directions to ensure the normal function and proper operation of the products. If not to follow these instructions to

properly install and normally use the products, you will not get the

warranty-committed compensation or protection. GlacialLight will not take any responsibility for any product damage caused by improper installation or abnormal usage.

1. Before installation, please turn off the power switch for the existing lamp.

2. Please make sure that both the AC voltage source and the power connector are compatible with the GL-SP15 series LED products.

• Pick a vantage point based on the directions of human and car traffic • Install the sensor at a location within 10 ~ 15 meter radius of the vantage point, 2.5 ~ 3 meter high and at an angel of adjustable sensor is up / down 10° ~ 30° (best at 90 degree)• Make sure the sensor is firmly screwed

Worst sensing effects

(Straightline moving forward)

Insufficent range due to low sensing angle

Short sensing range and prone to false detections due to high sensing angle

4. Please insulate properly the wires/terminals of the AC voltage source, screw tightly the GL-SP15 series LED products onto a wall or a stand, and adjust freely the lighting angle in accordance with individual needs.

5. Please turn on the AC voltage source to check whether the GL-SP15 series LED products can work normally. If not, please check carefully whether all the above installation steps are taken and usage conditions are met.

Installation Steps

Indicators on the bottom of the sensors

1. SENS: The intensity of sensing. + indicates strong sensing. - indicates weak sensing.

2. LUX: The brightness of the environment. Moon mark (>3 lux) indicates night sensing; effective when human entering the sensing area in low illuminations. Please avoid strong light resource because it may lead sensor to false detections. Sun Mark indicates 24-hour sensing regardless day or night. It is effective.

3. TIME: The light up time of sensing. From 7 seconds to 12 minutes.

SENS LUX TIME

10 m

15 m

(Lateral Moving)

Best sensing effects , Longest sensing range

2.5 m

3 m

3 m

Installation height and sensing angle are proper

~

~

10 m ~ 15 m

3 ~ 5 m90° ~ 100°

30° ~ 35°

Ground wiregreen

AC wire (N)white or blue

AC wire (L) black or brown

AC wire (L) black or brown

AC wire (N)white or blue

Ground wiregreen

3. The GL-SP15 series LED products feed only on an AC voltage source having an appropriate output voltage designated by the product specifications. Please connect respectively the Brown, Blue, and Green/yellow wires/terminals at the rear side of the GL-SP15 series LED products to the Line (L), Neutral (N), and Frame Ground (FG) wires/terminals of the AC voltage source. It depends on the model in use that the Brown, Blue, and Green/Yellow wires may be not screwed or screwed internally onto a terminal block. Misusing an inappropriate voltage source may lead to product damage.

CAUTIONCLASS 2 LED LIGHT

Do not stare at the beam.

Installation procedure should be undertaken by qualified technical personnel.

Optical

Mechanical and Dimension

Electrical

Temperature Condition

Model No.

CCT (Typical)

GL-SP15-WW(Warm White)

GL-SP15CW (Cool White)

GL-SP15S-WWGL-SP15C5-WW GL-SP15C6-WW

(Warm White)

GL-SP15S-CWGL-SP15C5-CW GL-SP15C6-CW

(Cool White)

Luminous Flux (lm)

Typical Luminous Efficacy CRI (Ra)

Beam Angle

Net. Weight

Power Factor

Cover

3000 K

720 lm

36 lm / W 35 lm / W> 80

30° / 60° (Optional)

6000 K

1050 lm

53 lm / W 50 lm / W> 75

Outline Dim. 185 × 175 × 130 (mm) 185 × 260 × 140 (mm) 185 × 175 × 130 (mm) 185 × 260 × 140 (mm)

Specifications GL-SP15 Series Outlook

All rights reserved. All brand names and trademarks are the properties of their respective owners. The specifications are subject to change without notice.

17-SP15S000002

» GL-SP15

Sensor Style

Sensing Coverage

Detection Range

Light Up Time

Operating Hours

Protection Device

Image Pick-up Device Sony 1/3" color CCD

Gamma Characteristic

Lens Furnished

Video Output

S/N Ratio

Automatic infrared heat detector

4-15 meters. Center-horizontal moving

90° – 110°

7 seconds to 12 minutes

24 hrs

Inlaid with 220 V / 10A 5 x 20 mm fuse

Gain Control

Signal

Horizontal Resolution

0.45

Board lens 3.6 mm / 6 mm / 8 mm / f2.0

1 vp-p composite video / 75 ohms

More than 48 dB

Automatically

24H 1Vp-p video signal output

380TVL (optional 480TVL / 540TVL)

Sensor (optional)

CCD (optional)

Lux at 1 M (60°)

Lux at 1 M (30°)

373 450

1025

1.2 (Kgs)

20 W

> 0.9 for 115V AC; > 0.8 for 230V AC

100 - 240V AC

60 Hz (110V) / 50 Hz (220V)

21 W 20 W 21 W

1.3 (Kgs) 1.2 (Kgs) 1.3 (Kgs)

1265

-20 °C - +40 °C

-40 °C - +85 °C

185.0 mm 130.0 mm

175.

0 m

m

185.0 mm 140.0 mm

260.

0 m

m

» Sensor - GL-SP15S

185.0 mm

260.

0 m

m

140.0 mm

» CCD (Optional) - GL-SP15C5 / GL-SP15C6

Clear

Typical Power consumption

Input Voltage

Work Frequency

Operating Temperature

Storage Temperature

SP-15W-CW 60°

SP-15W-WW 60° SP-15W-WW 30°

SP-15W-CW 30°

(LUX)

Candle Power Distribution Curve ( 15 W / 1 M)

IP54 IP65 (without sensor type)

-15 15

45

3030-

-

-

--

45

90

6 0

75

9075

60

0

0 300300600 600 12001200 900 900 15001500 ( )LUX

m

1m

2m

3m

4m

5m

mo

0.27m

0.54m

0.8m

1.07m

1.34m

lux

1449

363

189

90

58

15

75

60

90

75

45

60

90--

-

-

30-30

45

-15 0

0 120120240 240 480480 360 360 600600 ( )LUX

m

1m

2m

3m

4m

5m

mo

0.58m

1.16m

1.73m

2.3m

2.89m

lux

517

129

64

32

20

0-15 15

45

3030-

-

--

-

45

90

6 0

75

9075

60

0 250250500 500 10001000 750 750 12501250 ( )LUX

m

1m

2m

3m

4m

5m

mo

0.27m

0.54m

0.8m

1.07m

1.34m

lux

1178

294

149

73

47

0-15 15

45

3030-

-

-

--

45

90

6 0

75

9075

60

0 100100200 200 400400 300 300 500500 ( )LUX

m

1m

2m

3m

4m

5m

mo

0.58m

1.16m

1.73m

2.3m

2.89m

lux

428

107

53

26

17