g&l series ssh - hamiltonengineering.comhamiltonengineering.com/pdf/goulds ssh.pdf · john...

36
G&L Series SSH S & M-GROUP 316 STAINLESS STEEL END SUCTION PUMPS BOMBAS DE SUCCIÓN FINAL DE 316 ACERO INOXIDABLE GRUPO-M Y S TECHNICAL BROCHURE BSSH

Upload: leliem

Post on 18-Mar-2018

232 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

G&L Series SSHS & M-GROUP 316 STAINLESS STEEL END SUCTION PUMPS

BOMBAS DE SUCCIÓN FINAL DE 316 ACERO INOXIDABLE GRUPO-M Y S

TECHNICAL BROCHUREBSSH

Page 2: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 2

Commercial WaterGoulds Water Technology

A FULL RANGE OF PRODUCT FEATURES,UNA GAMA TOTAL DE CARACTERÍSTICAS DEL PRODUCTO

Superior Materials of Construction: AISI Type 316L stainless steel pump parts for reduced corrosion and improved strength and ductility.

Frame Mounted De-sign: Flexibility of instal-lation and driver arrange-ments.

Back Pull-Out Design: Simplifies maintenance when used with spacer type coupling.

Cast Iron Power Frame: Rigidly supported, grease lubricated ball bear-ing assembly.

Sello Mecánico: Sello mecánico estándar John Crane Tipo 21.

Motores de Accio-namiento: Motores de armazón-T NEMA estándar unifásicos o trifásicos.

Bridas de Succión y Descarga: Acoplan con bridas ANSI clase 150.

Diseño de Acople Cer-rado: El diseño compacto ahorra espacio y simplifica el mantenimiento.

Materiales Superiores de Construcción: Partes de la bomba de acero inox-idable AISI Tipo 316L para corrosión reducida y fuerza y ductilidad mejoradas.

Diseño de Armazón Montado: Flexibilidad de instalación y colocación del motor.

Diseño de Extracción Trasera: Simplifica el mantenimiento cuando se usa con el acople tipo espaciador.

Armazón del Motor de Hierro Fundido: Rígi-damente soportado, con ensamblaje de balineras de bolas lubricadas con grasa .

Mechanical Seal: Stan-dard John Crane Type 21 mechanical seal.

Drive Motors: Standard NEMA design T-frame or JM motors in single or three phase.

Suction and Discharge Flanges: Mate with ANSI class 150 flanges.

Close-Coupled Design: Compact design saves space and simplifies main-tenance.

Page 3: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 3

Commercial WaterGoulds Water Technology

PERFORMANCE COVERAGE, 3500 AND 1750 RPMALCANCE DE FUNCIONAMIENTO, 3500 Y 1750 RPM

150

125

100

75

50

25

0

40

30

20

10

04003002001000 600

40 60 160 180m3/hrCAPACITY (CAPACIDAD) – U.S. GPM

TOTA

L DYN

AMIC

HEA

D (C

ARGA

DIN

AMIC

A TO

TAL)

METERS(METROS)

FEET(PIES)

500 800

0

1750 RPM

700

20 80 100 120 140

23SH

27SH

22SH

6SH

25SH

24SH

11SH

10SH

9SH8SH

5SH4SH

28SH

7SH

600

500

400

0

100

75

50

25

04003002001000 600

40 60 160 260 m3/hrCAPACITY (CAPACIDAD) – U.S. GPM

TOTA

L DYN

AMIC

HEA

D (C

ARGA

DIN

AMIC

A TO

TAL)

METERS(METROS)

FEET(PIES)

500 800

0

3500 RPM

700

20 80 100 120 140

100

200

300

1000900 12001100

180 200 220 240

125

150

175

23SH

27SH

22SH

6SH5SH

8SH

25SH

24SH

11SH

10SH

7SH

9SH

4SH

28SH

Page 4: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 4

Commercial WaterGoulds Water Technology

Impeller Code,

Código del impulsor

24 SH 1 Q 1 2 A 0Example Product Code, Ejemplo Código del Producto

Mechanical Seals and O-Ring0 = Pre-engineered standard For optional mechanical seal modify catalog order no. with seal code listed below. Sello Mecánico y Anillo ‘0’0 = Estándar aprobado. Para sello mecánico opcional modificar el número de orden del catálogo con el código del sello anotado abajo.

Motor Enclosure, Caja del motor1 = ODP 5 = TEFC Premium Eff., Eficiencia superior2 = TEFC 6 = XP Premium Eff., Eficiencia superior3 = Explosion Proof, Prueba de explosiones 7 = Wash down, Lavado4 = ODP Premium Eff., Eficiencia superior

Motor Voltage, Voltaje del motor1 = 115/208-230 3 = 230 5 = 208-230/460 7 = 5752 = 115/230 4 = 230/460 6 = 460

HP Rating, Potencia nominal, HPC = ½ F = 1.5 J = 5 M = 15 Q = 30 T = 60D = .75 G = 2 K = 7.5 N = 20 R = 40 U = 75E = 1 H = 3 L = 10 P = 25 S = 50 V = 100

Driver: Hertz/Pole/RPM, Fuerza motriz: Hertz/Polos/RPM1 = 60/3500/1 3 = 60/1750/1 5 = 50/2900/12 = 60/3500/3 4 = 60/1750/3 6 = 50/2900/3

MaterialSH = 316L Stainless steel, Acero inoxidable

Pump Size, Tamaño de la Bomba9 = 1 x 2 – 6 4 = 1½ x 2½ – 6 8 = 2 x 2½ – 810 = 1 x 2 – 8 7 = 1½ x 2½ – 8 6 = 2½ x 3 – 611 = 1 x 2 – 10 5 = 2 x 2½ – 6 22 = 2½ x 3 – 823 = 3 x 4 – 8 24 = 1½ x 2½ – 10 25 = 2 x 2½ – 1027 = 2½ x 3 – 10 28 = 3 x 4 – 10

Pump Size, Tamaño de la Bomba

Seal Code,

Códigodel

Sello

Elastomers,Elastómeros

Stationary,Estacionario

Rotary,Rotativo

Part No., Pieza NúmeroMetal Parts,

Partes Metálicas

SSH S/M-GROUP NUMBERING SYSTEMSISTEMA DE NUMERACIÓN DEL GRUPO-S/M SSH

John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21

Impeller Option CodeFor optional impeller diameters modify catalog order no. with impeller code listed below. Select optional impeller diameter from pump performance curve.

Código del Impulsor OpcionalPara diámetros del impulsor opcional modificar el número de orden del catálogo con el código del impulsor anotado abajo. Seleccionar el diámetro del impulsor opcional de la curva de funcionamiento de la bomba.

180-210 250-360 Frames, Frames, Armazones Armazones

NOTE: Not all combinations of motor, impeller and seal options are available for every pump model. Please check with G&L on non-cataloged numbers.

NOTA: No todas las combinaciones de las opciones de motor, impulsor y sello están disponibles para cada modelo de bombas. Por favor verifique con G&L en los números no catalogados.

9SH 10SH 11SH 4SH 7SH 5SH 8SH 6SH 22SH 23SH 24SH 25SH 27SH 28SH 1 x 2-6 1 x 2-8 1 x 2-10 1½ x 2½-6 1½ x 2½-8 2 x 2½-6 2 x 2½-8 2½ x 3-6 2½ x 3 – 8 3 x 4 – 8 1½ x 2½ – 10 2 x 2½ – 10 2½ x 3 – 10 3 x 4 – 10 Dia. Dia. Dia. Dia. Dia. Dia. Dia. Dia. Dia. Dia. Dia. Dia. Dia. Dia. A 65⁄8 827⁄64 103⁄32 6¾ 8¼ 67⁄8 8¼ 75⁄16 91⁄16 91⁄16 97⁄8 97⁄8 103⁄8 105⁄8 B 67⁄16 81⁄16 917⁄32 63⁄8 713⁄16 67⁄16 7¾ 71⁄8 8¾ 811⁄16 9½ 9½ 915⁄16 10¼ C 511⁄16 711⁄16 91⁄8 61⁄16 7 513⁄16 7½ 615⁄16 8½ 87⁄16 93⁄16 91⁄8 99⁄16 913⁄16

D 53⁄8 73⁄8 8¾ 55⁄8 6¾ 5½ 73⁄16 611⁄16 8¼ 81⁄16 87⁄8 813⁄16 9¼ 97⁄16

E 71⁄8 55⁄16 67⁄16 51⁄8 67⁄8 63⁄8 77⁄8 711⁄16 89⁄16 83⁄16 8¾ 91⁄16

F 411⁄16 61⁄8 413⁄16 63⁄16 61⁄16 7½ 7½ 8¼ 715⁄16 811⁄16

G 43⁄8 47⁄16 55⁄8 71⁄8 71⁄8 711⁄16 H 43⁄16 611⁄16 67⁄8 J 6½ 6½ K 6 L 5½

0 Carbon Sil-Carb

Viton 316 SS, 10K27 10K45 2 EPR 316 Acero 10K19 10K20 5 Sil-Carb Sil-Carb Viton inoxidable 10K64 10K65

Frame Options, Opciones de mando Substitute, Description, Substituto Descripción

FRM2 7/8" Imp. Bore, Diámetro

interior del impulsor 7/8"

FRM3 1¼" Imp. Bore, Diámetro

interior del impulsor 1¼"

Page 5: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 5

Commercial WaterGoulds Water Technology

PERFORMANCE CURVES – 60 HZ, 3500 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 3500 RPM

0 10 20

1251007550250

50

200

10

40

00

20

30

60

150

100

Model SSH / 9SHSize (Tamaño) 1 x 2-6RPM 3500 Curve (Curva) CN0619R00

METERSMETROS

FEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) (H

)

CAPACITY (CAPACIDAD) (Q)

m3/ hr

U.S. GPM

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior alimpreso en la curva H-Q.

150

49

54

3025155

50

5'

8'

10'

39

56 EFF%

A 65/8" DIA.

B 67/16"

C 511/16"

D 53/8"

3 HP

5 HP

NPSHR – FEET (PIES)

0 10 20

125100755025050

300

40

20

30

90

150

100

Model SSH / 10SHSize (Tamaño) 1 x 2-8RPM 3500 Curve (Curva) CN0613R00

METERSMETROS

FEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) (H

)

CAPACITY (CAPACIDAD) (Q)

m3/ hr

U.S. GPM

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior alimpreso en la curva H-Q.

200

4025155

50

150 175

200

250

60

70

80

3530

NPSHR – FEET (PIES)

22'18'

14'10'

6'

42

49

47

33

42 EFF%

10 HP

B 81/16"

D 73/8"

C 711/16"

E 71/8"

71/2 HP

A 827/64" DIA.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 65⁄8" 5

B 67⁄16 5

C 511⁄16 3

D 53⁄8 3

NOTE: Pump will pass a sphere to 1⁄8" diameter.

NOTA: La bomba pasará una esfera a 1⁄8" diámetro.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 827⁄64" 10

B 81⁄16 10

C 711⁄16 7½

D 73⁄8 7½

E 71⁄8" 7½

NOTE: Pump will pass a sphere to 1⁄8" diameter.

NOTA: La bomba pasará una esfera a 1⁄8" diámetro.

Page 6: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 6

Commercial WaterGoulds Water Technology

PERFORMANCE CURVES – 60 HZ, 3500 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 3500 RPM

0 10 20

125100755025050

450

40

20

30

130

150

100

Model SSH / 11SHSize (Tamaño) 1 x 2-10RPM 3500 Curve (Curva) CN0616R00

METERSMETROS

FEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) (H

)

CAPACITY (CAPACIDAD) (Q)

m3/ hr

U.S. GPM

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior alimpreso en la curva H-Q.

200

4025155

50

150 175

200

250

60

70

80

3530

400

350

30090

120

110

100

20 HP

15 HP

22’

NPSHR – FEET (PIES)

25'

27'

29'

30

38

43 EFF%

A 103/32" DIA.

B 917/32"

C 91/8"

D 83/4"

45

10 HP

43

0 10 20 60

100500

50

125

175

10

40

00

20

30

50

150

100

75

25

Model SSH / 4SH Size (Tamaño) 11/2 x 21/2-6RPM 3500Curve (Curva) CN0488R01METERS

METROSFEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) (H

)

CAPACITY (CAPACIDAD) (Q)

m3/ hr

U.S. GPM

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior alimpreso en la curva H-Q.

150 200 250

504030

60

2 HP

3 HP

5 HP

10 HP

71/2 HP

5559

61 6365

65

63

EFF%61

NPSHR – FEET (PIES)5'

12'

8'

F 411/16"

D 55/8"

B 63/8"

A 63/4" DIA.

G 43/8"

H 43/16"

C 61/16"

E 55/16"

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 103⁄32" 20

B 917⁄32 15

C 91⁄8 15

D 8¾ 15

NOTE: Pump will pass a sphere to 1⁄8" diameter.

NOTA: La bomba pasará una esfera a 1⁄8" diámetro.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 6¾" 10

B 63⁄8 7½

C 61⁄16 7½

D 55⁄8 5

E 55⁄16 5

F 411⁄16 3

G 43⁄8 3

H 43⁄16 2

NOTE: Pump will pass a sphere to 3⁄16" diameter.

NOTA: La bomba pasará una esfera a 3⁄16" diámetro.

Page 7: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 7

Commercial WaterGoulds Water Technology

PERFORMANCE CURVES – 60 HZ, 3500 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 3500 RPM

0 10 20 60

15075500

50

200

250

10

40

00

20

30

50

225

100

75

25

Model SSH / 7SH Size (Tamaño) 11/2 x 21/2-8RPM 3500Curve (Curva) CN0491R00METERS

METROSFEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) (H

)

CAPACITY (CAPACIDAD) (Q)

m3/ hr

U.S. GPM

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

175 200 275

504030

27580

125

150

175

70

60

25022512510025

10 HP

71∨2 HP

15 HP

5958

EFF%57

56 5758

59

5055

40

D 63/4"

A 81/4" DIA.

E 67/16"

B 713/16"

C 7"

F 61/8"

6'

8'

10'

14'

NPSHR – FEET (PIES)

0 20 40 100

2000

75

125

175

10

40

00

20

30

150

50

Model SSH / 5SH Size (Tamaño) 2 x 21/2-6RPM 3500Curve (Curva) CN0494R01METERS

METROSFEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) (H

)

CAPACITY (CAPACIDAD) (Q)

m3/ hr

U.S. GPM

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior alimpreso en la curva H-Q.

250 300

8060

60

50

35015010050

25

100

400

71∨2 HP

10 HP

15 HP

5 HP

6867

EFF%66

686766

64

60

50

D 51/2"

A 67/8" DIA.

E 51/8"

B 67/16"

C 513/16"

F 413/16"

G 47/16"

NPSHR – FEET (PIES)6'

10'

14'

19'

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 8¼" 15

B 713⁄16 15

C 7 10

D 6¾ 10

E 67⁄16 7½

F 61⁄8 7½

NOTE: Pump will pass a sphere to 3⁄16" diameter.

NOTA: La bomba pasará una esfera a 3⁄16" diámetro.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 67⁄8" 15

B 67⁄16 15

C 513⁄16 10

D 5½ 10

E 51⁄8 7½

F 413⁄16 7½

G 47⁄16 5

NOTE: Pump will pass a sphere to 3⁄16" diameter.

NOTA: La bomba pasará una esfera a 3⁄16" diámetro.

Page 8: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 8

Commercial WaterGoulds Water Technology

PERFORMANCE CURVES – 60 HZ, 3500 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 3500 RPM

0 20 40 100

2000

150

250

10

40

00

20

30

200

50

Model SSH / 8SH Size (Tamaño) 2 x 21/2-8RPM 3500Curve (Curva) CN0497R01METERS

METROSFEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) (H

)

CAPACITY (CAPACIDAD) (Q)

m3/ hr

U.S. GPM

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior alimpreso en la curva H-Q.

250 300

8060

30090

50

35015010050

100

400

80

70

60

A 81/4" DIA.

E 67/8"

B 73/4"

F 63/16"

C 71/2"

D 73/16"

15 HP20 HP

25 HP

10 HP

69

EFF%65

71

71

69656050

NPSHR – FEET (PIES)8'

10'

13'

16'

21'

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 8¼" 25

B 7¾ 20

C 7½ 20

D 73⁄16 15

E 67⁄8 15

F 63⁄16 10

NOTE: Pump will pass a sphere to ¼" diameter.

NOTA: La bomba pasará una esfera a ¼" diámetro.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 75⁄16" 25

B 71⁄8 25

C 615⁄16 20

D 611⁄16 20

E 63⁄8 15

F 61⁄16 15

G 55⁄8 10

NOTE: Pump will pass a sphere to 5⁄16" diameter.

NOTA: La bomba pasará una esfera a 5⁄16" diámetro.

0 25 50 150

3000

150

250

10

40

00

20

30

200

50

Model SSH / 6SH Size (Tamaño) 21/2 x 3-6RPM 3500Curve (Curva) CN0500R00METERS

METROSFEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) (H

)

CAPACITY (CAPACIDAD) (Q)

m3/ hr

U.S. GPM

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior alimpreso en la curva H-Q.

400 500

75

80

50

600200100

100

700

70

60

E 63/8"

A 75/16" DIA.

F 61/16"

B 71/8"C 615/16"

G 55/8"

NPSHR – FEET (PIES)7'

60

65

7070

68

8'

10'

13'

66

EFF%60

15'

6520'

10 HP

20 HP

25 HP

125100 175

D 611/16"

63

15 HP

25'

Page 9: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 9

Commercial WaterGoulds Water Technology

PERFORMANCE CURVES – 60 HZ, 1750 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 1750 RPM

50403020100

10

0

20

Model SSH / 9SHSize (Tamaño) 1 x 2-6RPM 1750 Curve (Curva) CN0620R00

FEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) (H

)

CAPACITY (CAPACIDAD) (Q)

U.S. GPM

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior alimpreso en la curva H-Q.

80

6'

50

55 EFF%

A 65/8" DIA.

B 67/16"

C 511/16"

D 53/8"

NPSHR – FEET (PIES)

30

40

50

60 70

4'55

565'

8'

1/2 HP

3/4 HP

504030201000

70

40

30

Model SSH / 10SHSize (Tamaño) 1 x 2-8RPM 1750 Curve (Curva) CN0614R00

FEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) (H

)

CAPACITY (CAPACIDAD) (Q)

U.S. GPM

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior alimpreso en la curva H-Q.

8060 70

50

60

8'47

49 EFF%

20

10

1 HP

NPSHR – FEET (PIES)4'A 827/64" DIA.

C 711/16"

B 81/16"

E 71/8"

D 73/8"

3/4 HP

11/2 HP

5'42

6'

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 65⁄8" ¾

B 67⁄16 ¾

C 511⁄16 ½

D 53⁄8 ½

NOTE: Pump will pass a sphere to 1⁄8" diameter.

NOTA: La bomba pasará una esfera a 1⁄8" diámetro.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 827⁄64" 1½

B 81⁄16 1½

C 711⁄16 1

D 73⁄8 ¾

E 71⁄8 ¾

NOTE: Pump will pass a sphere to 1⁄8" diameter.

NOTA: La bomba pasará una esfera a 1⁄8" diámetro.

Page 10: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 10

Commercial WaterGoulds Water Technology

PERFORMANCE CURVES – 60 HZ, 1750 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 1750 RPM

502500

120

40

20

Model SSH / 11SHSize (Tamaño) 1 x 2-10RPM 1750 Curve (Curva) CN0617R00

FEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) (H

)

CAPACITY (CAPACIDAD) (Q)

U.S. GPM

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior alimpreso en la curva H-Q.

10075

60

100

80

2 HP

NPSHR – FEET (PIES)

12' 14'

17'

36

43 EFF%

A 103/32"

B 917/32"

C 91/8"

D 83/4"

45

1 HP

43

38

3 HP

8'

Model SSH / 4SH Size (Tamaño) 11/2 x 21/2-6RPM 1750Curve (Curva) CN0489R01

0 10 30

800

30

10

00

40

20

METERSMETROS

FEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) (H

)

CAPACITY (CAPACIDAD) (Q)

m3/ hr

U.S. GPM100 120

252015

15

F 411/16"

D 55/8"

C 61/16"

A 63/4" DIA.

G 43/8"H 43/16"

5459

62

62

61

EFF%60

NPSHR – FEET (PIES)4'

6'

10

604020

5

5

8'

1/2 HP

1 HP

3/4 HP

B 63/8"

E 55/16"

60 61

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior alimpreso en la curva H-Q.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 103⁄32" 3

B 917⁄32 3

C 91⁄8 2

D 8¾ 2

NOTE: Pump will pass a sphere to 1⁄8" diameter.

NOTA: La bomba pasará una esfera a 1⁄8" diámetro.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 6¾" 1

B 63⁄8 1

C 61⁄16 1

D 55⁄8 ¾

E 55⁄16 ¾

F 411⁄16 ½

G 43⁄8 ½

H 43⁄16 ½

NOTE: Pump will pass a sphere to 3⁄16" diameter.

NOTA: La bomba pasará una esfera a 3⁄16" diámetro.

Page 11: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 11

Commercial WaterGoulds Water Technology

PERFORMANCE CURVES – 60 HZ, 1750 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 1750 RPM

Model SSH / 7SH Size (Tamaño) 11/2 x 21/2-8RPM 1750Curve (Curva) CN0492R00

0 10 30

80600

40

00

m3/ hr

U.S. GPM

252015

20

15

10

12020

11∨2 HP

5756

EFF%55

54 5556

57

4853

38

D 63/4"

E 67/16"

B 713/16"

C 7"

F 61/8"

NPSHR – FEET (PIES)6'

10'

13'

205

5

10040

8'

2 HP

1 HP

60

A 81/4" DIA.

METERSMETROS

FEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) (H

)

CAPACITY (CAPACIDAD) (Q)

NOTE: Not recommended for operation beyond printed H-Q curve.

NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

Model SSH / 5SH Size (Tamaño) 2 x 21/2-6RPM 1750Curve (Curva) CN0495R00

0 20 30

0

40

10

00

30

m3/ hr

U.S. GPM120

5040

160

20

200

1 HP

6766

65

676665

63

58

48

D 51/2"

A 67/8" DIA.

E 51/8"

B 67/16"

C 513/16"

F 413/16"

G 47/16"

NPSHR – FEET (PIES)4'

12'

10

40 80

10

5

7'

9'

2 HP

11/2 HP

3/4 HP

EFF%

METERSMETROS

FEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) (H

)

CAPACITY (CAPACIDAD) (Q)

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior alimpreso en la curva H-Q.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia A 8¼" 2

B 713⁄16 2

C 7 1½

D 6¾ 1½

E 67⁄16 1

F 61⁄8 1

NOTE: Pump will pass a sphere to 3⁄16" diameter.

NOTA: La bomba pasará una esfera a 3⁄16" diámetro.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 67⁄8" 2

B 67⁄16 2

C 513⁄16 1½

D 5½ 1½

E 51⁄8 1

F 413⁄16 1

G 47⁄16 ¾

NOTE: Pump will pass a sphere to 5⁄32" diameter.

NOTA: La bomba pasará una esfera a 5⁄32" diámetro.

Page 12: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 12

Commercial WaterGoulds Water Technology

Model SSH / 8SH Size (Tamaño) 2 x 21/2-8RPM 1750Curve (Curva) CN0498R01

0 20 30

0

10

00

20

50

m3/ hr

U.S. GPM120

5040

16080 200

67

69

A 81/4" DIA.

E 67/8"

B 73/4"

F 63/16"

C 71/2"

D 73/16"

EFF%

69

6763

5848NPSHR – FEET (PIES)5'

11'

40

30

20

10

60

40

10

5

15

7'

9'

3 HP

2 HP11/2 HP

METERSMETROS

FEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) (H

)

CAPACITY (CAPACIDAD) (Q)

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior alimpreso en la curva H-Q.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 8¼" 3

B 7¾ 3

C 7½ 2

D 73⁄16 2

E 67⁄8 1½

F 63⁄16 1½

NOTE: Pump will pass a sphere to 5⁄32" diameter.

NOTA: La bomba pasará una esfera a 5⁄32" diámetro.

0 25 50

3000

10

00

50

Model SSH / 6SH Size (Tamaño) 21/2 x 3-6RPM 1750Curve (Curva) CN0502R00

m3/ hr

U.S. GPM 400

75

20

200100

E 63/8"

A 75/16" DIA.

F 61/16"

C 615/16"

G 55/8"

NPSHR – FEET (PIES)4'

57

62

6767

65

5'

63

EFF%57

11'

6215'

60

2 HP

19'

7'

9'

11/2 HP

3 HP

B 71/8"

D 611/16"

60

40

30

20

10

15

5

METERSMETROS

FEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) (H

)

CAPACITY (CAPACIDAD) (Q)

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior alimpreso en la curva H-Q.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 75⁄16" 3

B 71⁄8 3

C 615⁄16 3

D 611⁄16 3

E 63⁄8 2

F 61⁄16 2

G 55⁄8 1½

NOTE: Pump will pass a sphere to 5⁄16" diameter.

NOTA: La bomba pasará una esfera a 5⁄16" diámetro.

PERFORMANCE CURVES – 60 HZ, 1750 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 1750 RPM

Page 13: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 13

Commercial WaterGoulds Water Technology

1007550250 U.S. GPM

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior alimpreso en la curva H-Q.

1501250

250

150

100

Model SSH / 10SHSize (Tamaño) 1 x 2-8RPM 2900 Curve (Curva) CN0615R00

FEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) (H

)

CAPACITY (CAPACIDAD) (Q)

2005'

49 EFF%

50

A 827/64" DIA.

D 73/8"

E 71/8"

C 711/16"

B 81/16"

7' 42

12’

NPSHR – FEET (PIES)

47

3 HP

5 HP

9’

402000

20

Model SSH / 9SHSize (Tamaño) 1 x 2-6RPM 2900 Curve (Curva) CN0621R00

FEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) (H

)

CAPACITY (CAPACIDAD) (Q)

U.S. GPM

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior alimpreso en la curva H-Q.

80

40A 65/8" DIA.

B 67/16"

C 511/16"

D 53/8"

60

40

120

60 100

80

100

120

50

5'

7'55 EFF%

3 HP

2 HP

NPSHR – FEET (PIES)

1/2 HP

56

55

4'

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 65⁄8" 3

B 67⁄16 3

C 511⁄16 2

D 53⁄8 2

NOTE: Pump will pass a sphere to 1⁄8" diameter.

NOTA: La bomba pasará una esfera a 1⁄8" diámetro.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 827⁄64" 5

B 81⁄16 5

C 711⁄16 5

D 73⁄8 5

E 71⁄8 3

NOTE: Pump will pass a sphere to 1⁄8" diameter.

NOTA: La bomba pasará una esfera a 1⁄8" diámetro.

PERFORMANCE CURVES – 50 HZ, 2900 RPMCURVAS DE FUNCIONAMIENTO – 50 HZ, 2900 RPM

Page 14: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 14

Commercial WaterGoulds Water Technology

50250

300

100

50

Model SSH / 11SHSize (Tamaño) 1 x 2-10RPM 2900 Curve (Curva) CN0618R00

FEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) (H

)

CAPACITY (CAPACIDAD) (Q)

U.S. GPM

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior alimpreso en la curva H-Q.

17575

250

8’

NPSHR – FEET (PIES)

14’18'

20'

30

43 EFF%

A 103/32" DIA.

B 917/32"

C 91/8"

D 83/4"

45

43

38

100 125 150

150

200

10 HP

71/2 HP

Model SSH / 4SH Size (Tamaño) 11/2 x 21/2-6RPM 2900Curve (Curva) CN0490R01

0 10 20 50

120800

60

120

10

00

20

30 100

80

40

m3/ hr

U.S. GPM160 200

4030

40

20

40

1 HP

5 HPF 411/16"

D 55/8"

C 61/16"

B 63/8"

A 63/4" DIA.

G 43/8"H 43/16"

5560

61 6264

64

62

EFF%61

NPSHR – FEET (PIES)4'

6'

8'

2 HP

3 HP

E 55/16"

METERSMETROS

FEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) (H

)

CAPACITY (CAPACIDAD) (Q)

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior alimpreso en la curva H-Q.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 103⁄32" 15

B 917⁄32 10

C 91⁄8 10

D 8¾ 7½

NOTE: Pump will pass a sphere to 1⁄8" diameter.

NOTA: La bomba pasará una esfera a 1⁄8" diámetro.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 6¾" 5

B 63⁄8 5

C 61⁄16 5

D 55⁄8 3

E 55⁄16 3

F 411⁄16 2

G 43⁄8 2

H 43⁄16 1½

NOTE: Pump will pass a sphere to 3⁄16" diameter.

NOTA: La bomba pasará una esfera a 3⁄16" diámetro.

PERFORMANCE CURVES – 50 HZ, 2900 RPMCURVAS DE FUNCIONAMIENTO – 50 HZ, 2900 RPM

Page 15: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 15

Commercial WaterGoulds Water Technology

0 10 20 50

12080400

40

200

10

40

00

20

30

50

80

Model SSH / 7SH Size (Tamaño) 11/2 x 21/2-8RPM 2900Curve (Curva) CN0493R00

m3/ hr

U.S. GPM160 200

4030

60

120

160

71/2 HP

10 HP

5857

EFF%56

55 5657

58

4954

39

D 63/4"

A 81/4" DIA.

E 67/16"

B 713/16"

C 7"

F 61/8"

NPSHR – FEET (PIES)6'

13'

17'

8'

5 HP

METERSMETROS

FEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) (H

)

CAPACITY (CAPACIDAD) (Q)

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior alimpreso en la curva H-Q.

Model SSH / 5SH Size (Tamaño) 2 x 21/2-6RPM 2900Curve (Curva) CN0496R01

0 20 40

2000

80

120

10

00

20

30

60

CAPACITY (CAPACIDAD) (Q)

m3/ hr

U.S. GPM280 320

8060

40

36016080

40

100

20

71/2 HP

3 HP

6867

EFF%66

686766

64

59

49

D 51/2"

A 67/8" DIA.

E 51/8"

B 67/16"

C 513/16"

F 413/16"

G 47/16"

NPSHR – FEET (PIES)5'

10'

14'

24012040

70503010

7'

10 HP

5 HP

METERSMETROS

FEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) (H

)

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior alimpreso en la curva H-Q.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 8¼" 10

B 713⁄16 7½

C 7 7½

D 6¾ 7½

E 67⁄16 5

F 61⁄8 5

NOTE: Pump will pass a sphere to 3⁄16" diameter.

NOTA: La bomba pasará una esfera a 3⁄16" diámetro.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 67⁄8" 10

B 67⁄16 7½

C 513⁄16 7½

D 5½ 5

E 51⁄8 5

F 413⁄16 3

G 47⁄16 3

NOTE: Pump will pass a sphere to 5⁄32" diameter.

NOTA: La bomba pasará una esfera a 5⁄32" diámetro.

PERFORMANCE CURVES – 50 HZ, 2900 RPMCURVAS DE FUNCIONAMIENTO – 50 HZ, 2900 RPM

Page 16: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 16

Commercial WaterGoulds Water Technology

Model SSH / 8SH Size (Tamaño) 2 x 21/2-8RPM 2900Curve (Curva) CN0499R01

0 20 40

2000

160

10

40

00

20

30

80

m3/ hr

U.S. GPM240 280

8060

50

32016012080

120

360

EFF%

A 81/4" DIA.

E 67/8"

B 73/4"

C 71/2"

D 73/16"

10 HP

68

64

70

71

70

68645949

NPSHR – FEET (PIES)6'

13'

16'

40

40

10 30 50 70

7'

9'

15 HP

71/2 HP

F 63/16"

METERSMETROS

FEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) (H

)

CAPACITY (CAPACIDAD) (Q)

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior alimpreso en la curva H-Q.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 8¼" 15

B 7¾ 15

C 7½ 10

D 73⁄16 10

E 67⁄8 7½

F 63⁄16 7½

NOTE: Pump will pass a sphere to 5⁄32" diameter.

NOTA: La bomba pasará una esfera a 5⁄32" diámetro.

0 25 50

3000

150

10

40

00

20

30

50

Model SSH / 6SH Size (Tamaño) 21/2 x 3-6RPM 2900Curve (Curva) CN0501R00

m3/ hr

U.S. GPM400 500

75

50

600200100

100

125100

25

75

125

175

E 63/8"

A 75/16" DIA.

F 61/16"

C 615/16"

G 55/8"

NPSHR – FEET (PIES)

58

64

6969

67

7'

11'

65

62

EFF%58

13'17'

21'

10 HP

15 HP

D 611/16"

B 71/8"

6'

64

8'

71/2 HP

METERSMETROS

FEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) (H

)

CAPACITY (CAPACIDAD) (Q)

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior alimpreso en la curva H-Q.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 75⁄16" 15

B 71⁄8 15

C 615⁄16 15

D 611⁄16 10

E 63⁄8 10

F 61⁄16 7½

G 55⁄8 7½

NOTE: Pump will pass a sphere to 5⁄16" diameter.

NOTA: La bomba pasará una esfera a 5⁄16" diámetro.

PERFORMANCE CURVES – 50 HZ, 2900 RPMCURVAS DE FUNCIONAMIENTO – 50 HZ, 2900 RPM

Page 17: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 17

Commercial WaterGoulds Water Technology

0 20

200150100500

EFF

0

40

70

250

40 60

50

100

150

250

300

60

50

30

20

Model SSH – 25SH / Size (Tamaño) 2 x 21/2-10RPM 3500Curve (Curva) CN0506R00

METERSMETROS

FEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) H

CAPACITY (CAPACIDAD) Q

m3/hr

U.S. GPM

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

300

200

350

400

450

100

90

80

400350 450 500

80 100

130

120

110

10

55%60

7' NPSHR – FEET (PIES)

11'

20'

6263

64

6463

9'B 91/2"

C 91/8"

D 813/16"

E 83/16"F 715/16"G 711/16"

A 97/8" DIA.

30 HP

25 HP

40 HP

50 HP

0 20

2001501005000

250

40 60

50

100

150

250

300

Model SSH – 24SH / Size (Tamaño) 11/2 x 21/2-10RPM 3500Curve (Curva) CN0503R00

FEETPIES

CAPACITY (CAPACIDAD) Q

m3/hr

U.S. GPM

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

300

200

350

400

450

50%

5759

59

60

8'

10'

12'

55

25 HP

20 HP

A 97/8" DIA.

B 91/2"

C 93/16"

D 87/8"

E 89/16"

F 81/4"

40

70

60

50

30

20

METERSMETROS

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) H

100

90

80

130

120

110

10

6' NPSHR – FEET (PIES)

EFF55

30 HP

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 97⁄8" 50

B 9½ 40

C 91⁄8 40

D 813⁄16 30

E 83⁄16 30

F 715⁄16 25

G 711⁄16 25

NOTE: Pump will pass a sphere to ½" diameter.

NOTA: La bomba pasará una esfera a ½" diámetro.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 97⁄8" 30

B 9½ 30

C 93⁄16 25

D 87⁄8 25

E 89⁄16 20

F 8¼ 20

NOTE: Pump will pass a sphere to 5⁄16" diameter.

NOTA: La bomba pasará una esfera a 5⁄16" diámetro.

PERFORMANCE CURVES – 60 HZ, 3500 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 3500 RPM

Page 18: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 18

Commercial WaterGoulds Water Technology

50

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0 20

6005004003002001000

NPSHR – FEET (PIES)

B 83/4"A 91/16" DIA.

D 81/4"

50

100

700

40 180

E 77/8"

60 HP

8'

75

300

70

60

40

30

20

F 71/2"

50 HP

7'

C 81/2"

800

60 80 100 120 140

70

71

68

65

5060

40% EFF

Model SSH – 22SH / Size (Tamaño) 21/2 x 3-8RPM 3500Curve (Curva) CN0509R00METERS

METROSFEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) H

CAPACITY (CAPACIDAD) Q

m3/hr

U.S. GPM

350

325

275

250

225

200

175

150

125

100

80

90

160

H 611/16"

G 71/8"

J 61/2"

10'12'

15'

68

65

20'25'

30'

60

40 HP

30 HP25 HP20 HP

15 HP

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 91⁄16" 60

B 8¾ 50

C 8½ 50

D 8¼ 40

E 77⁄8 40

F 7½ 30

G 71⁄8 25

H 611⁄16 20

J 6½ 20

NOTE: Pump will pass a sphere to 19⁄32" diameter.

NOTA: La bomba pasará una esfera a 19⁄32" diámetro.

0

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0 20

6005004003002001000

NPSHR – FEET (PIES)

B 915/16"

A 103/8" DIA.

D 91/4"

50

175

700

40 180

E 83/4"

100 HP

50

300

75

25

0

7'

C 99/16"

800

60 80 100 120 140

5545% EFF

Model SSH – 27SH / Size (Tamaño) 21/2 x 3-10RPM 3500Curve (Curva) CN0512R00METERS

METROSFEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) H

CAPACITY (CAPACIDAD) Q

m3/hr

U.S. GPM

600

250

200

150

100

160

550

500

450

400

350100

125

150

75 HP

60 HP50 HP

40 HP

6065

69

6970

8'10'

12'15'

20'30'

65

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 103⁄8" 100

B 915⁄16 75

C 99⁄16 75

D 9¼ 60

E 8¾ 50

NOTE: Pump will pass a sphere to 19⁄32" diameter.

NOTA: La bomba pasará una esfera a 19⁄32" diámetro.

PERFORMANCE CURVES – 60 HZ, 3500 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 3500 RPM

Page 19: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 19

Commercial WaterGoulds Water Technology

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) H

0

0 40

120010008006004002000

NPSHR – FEET (PIES)

D 97/16"

C 913/16" DIA.

F 811/16"

50

175

1400

80 360

100 HP

50

0

10'

E 91/16"

1600

120 160 200 240 280

5545% EFF

Model SSH – 28SH / Size (Tamaño) 3 x 4-10RPM 3500Curve (Curva) CN0518R00METERS

METROSFEETPIES

CAPACITY (CAPACIDAD) Q

m3/hr

U.S. GPM

600

250

200

150

320

300

100

75

25

550

500

450

400

350

150

125

100

8'

65 7073

75

75

7676

73

12'14'

17'20'

25'

30'

75 HP

60 HP

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

C 913⁄16" 100

D 97⁄16 100

E 91⁄16 75

F 811⁄16 75

NOTE: Pump will pass a sphere to ¾" diameter.

NOTA: La bomba pasará una esfera a ¾" diámetro.

50

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior alimpreso en la curva H-Q.

0 40

120010008006004002000

NPSHR – FEET (PIES)

B 811/16"

A 91/16" DIA.

D 81/16"

50

100

1400

80 360

E 711/16"

75 HP

75

325

90

40

20

10'

C 87/16"

1600

120 160 200 240 280

6050% EFF

Model SSH – 23SH / Size (Tamaño) 3 x 4-8RPM 3500Curve (Curva) CN0515R00METERS

METROSFEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) H

CAPACITY (CAPACIDAD) Q

m3/hr

U.S. GPM

350

275

250

200

150

320

300

225

175

125

100

80

70

60

30

F 71/2"

G 71/8"

H 67/8"

J 61/2"

12'14'

17'

20'

25'

30'

70

7577

77

75

7878

70

60 HP

50 HP

40 HP30 HP25 HP

K 6"

L 51/2"

20 HP15 HP

100 HP

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 91⁄16" 75

B 811⁄16 75

C 87⁄16 60

D 81⁄16 50

E 711⁄16 50

F 7½ 40

G 71⁄8 40

H 67⁄8 30

J 6½ 25

K 6 20

L 5½ 15

NOTE: Pump will pass a sphere to ¾" diameter.

NOTA: La bomba pasará una esfera a ¾" diámetro.

PERFORMANCE CURVES – 60 HZ, 3500 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 3500 RPM

Page 20: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 20

Commercial WaterGoulds Water Technology

0 10

504030200

EFF

0100

20

10

20

30

50

60

30

20

Model SSH – 24SH / Size (Tamaño) 11/2 x 21/2-10RPM 1750Curve (Curva) CN0505R00

METERSMETROS

FEETPIES

TOTA

L D

YNA

MIC

HEA

D (C

ARG

A DI

NAM

ICA

TOTA

L) H

CAPACITY (CAPACIDAD) Q

m3/hr

U.S. GPM

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

150

40

70

100

110

80

90

10 90807060 110 120 130 140

45%

3' NPSHR – FEET (PIES)

50 5254

54

56

4'

5'

50

3 HP

2 HP

25

15

10

5

5 15 25 30

52

B 91/2"

C 93/16"

D 87/8"

E 89/16"

F 81/4"

A 97/8" DIA.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 97⁄8" 5

B 9½ 5

C 93⁄16 3

D 87⁄8 3

E 89⁄16 3

F 8¼ 2

NOTE: Pump will pass a sphere to 5⁄16" diameter.

NOTA: La bomba pasará una esfera a 5⁄16" diámetro.

0 10

806040200

EFF

100

15 20

Model SSH – 25SH / Size (Tamaño) 2 x 21/2-10RPM 1750Curve (Curva) CN0508R00

CAPACITY (CAPACIDAD) Q

m3/hr

U.S. GPM

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

120

25

0

10

20

30

50

60

FEETPIES

40

70

100

110

80

90

140 160 180 200 220 240

30

20

METERSMETROS

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) H

25

15

10

5

5 30 35 40 45 50 55

50%55

4' NPSHR – FEET (PIES)

5'

8'

5758

59

5958

3 HP

5 HP

7.5 HP

B 91/2"

C 91/8"

D 813/16"

E 83/16"F 715/16"G 711/16"

A 97/8" DIA.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 97⁄8" 7½

B 9½ 5

C 91⁄8 5

D 813⁄16 5

E 83⁄16 3

F 715⁄16 3

G 711⁄16 3

NOTE: Pump will pass a sphere to ½" diameter.

NOTA: La bomba pasará una esfera a ½" diámetro.

PERFORMANCE CURVES – 60 HZ, 1750 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 1750 RPM

Page 21: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 21

Commercial WaterGoulds Water Technology

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0

0 20

300250200150100500

NPSHR – FEET (PIES)

C 81/2"

A 91/16" DIA.

E 77/8"

10

35

350

30 100

10

0

D 81/4"

400

40 50 60 70 80

5040% EFF

Model SSH – 22SH / Size (Tamaño) 21/2 x 3-8RPM 1750Curve (Curva) CN0511R00METERS

METROSFEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) H

CAPACITY (CAPACIDAD) Q

m3/hr

U.S. GPM

120

90

15

5

110

10030

25

20

5'

7 1/2 HP20

30

40

50

60

70

80

90

450

10

G 71/8"

H 611/16"

5560 62

6260

64

55

50

6'

8'

10'

15'

5 HP3 HP

2 HP

0

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0 20

300250200150100500

NPSHR – FEET (PIES)

B 915/16"

A 103/8" DIA.

D 91/4"

10

3

350

30 100

10

0

C 99/16"

400

40 50 60 70 80

5550% EFF

Model SSH – 27SH / Size (Tamaño) 21/2 x 3-10RPM 1750Curve (Curva) CN0514R00METERS

METROSFEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) H

CAPACITY (CAPACIDAD) Q

m3/hr

U.S. GPM

120

90

15

5

110

1003

2

2

5'

7 1/2 HP

20

30

40

50

60

70

80

90

450

10

E 83/4"

5 HP

6063

63

66

66

68

68

55

60

7'

15'

20'

10'

10 HP

15 HP

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 91⁄16" 7½

C 8½ 7½

D 8¼ 5

E 77⁄8 5

G 71⁄8 3

H 611⁄16 3

NOTE: Pump will pass a sphere to 19⁄32" diameter.

NOTA: La bomba pasará una esfera a 19⁄32" diámetro.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 103⁄8" 15

B 915⁄16 10

C 99⁄16 10

D 9¼ 7½

E 8¾ 7½

NOTE: Pump will pass a sphere to 19⁄32" diameter.

NOTA: La bomba pasará una esfera a 19⁄32" diámetro.

PERFORMANCE CURVES – 60 HZ, 1725 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 1725 RPM

Page 22: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 22

Commercial WaterGoulds Water Technology

0

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior alimpreso en la curva H-Q.

0 40

6005004003002001000

NPSHR – FEET (PIES)

C 87/16"

A 91/16" DIA.

F 71/2"

10

35

700

60 200

10

0

D 81/16"

800

80 100 120 140 160

5545% EFF

Model SSH – 23SH / Size (Tamaño) 3 x 4-8RPM 1750Curve (Curva) CN0517R00METERS

METROSFEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) H

CAPACITY (CAPACIDAD) Q

m3/hr

U.S. GPM

120

180

15

5

110

10030

25

20

5'

7 1/2 HP20

30

40

50

60

70

80

90

900

20

G 71/8"

3 HP

J 61/2"

6568

71

73

73

74

71

6'8'

10'

6865

55

15'

5 HP

10 HP

10

20

0 40

6005004003002001000

NPSHR – FEET (PIES)

B 101/4"

A 105/8" DIA.

D 97/16"

40

700

60 200

C 913/16"

800

80 100 120 140 160

5545% EFF

Model SSH – 28SH / Size (Tamaño) 3 x 4-10RPM 1750Curve (Curva) CN0520R00METERS

METROSFEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) H

CAPACITY (CAPACIDAD) Q

m3/hr

U.S. GPM

180

15

130

120

30

25

20

7'

30

40

50

60

70

80

90

900

20

10 HP

110

100

35

6570

15 HP

20 HP

73

73

74

70

65

8'

10'

15'20'

30'

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 91⁄16" 10

C 87⁄16 7½

D 81⁄16 7½

F 7½ 5

G 71⁄8 5

J 6½ 3

NOTE: Pump will pass a sphere to ½" diameter.

NOTA: La bomba pasará una esfera a ½" diámetro.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 105⁄8" 20

B 10¼ 15

C 913⁄16 15

D 97⁄16 15

NOTE: Pump will pass a sphere to ¾" diameter.

NOTA: La bomba pasará una esfera a ¾" diámetro.

PERFORMANCE CURVES – 60 HZ, 1725 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 1725 RPM

Page 23: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 23

Commercial WaterGoulds Water Technology

0 20

200120100400

EFF

0

40

70

220

40

50

100

150

250

300

60

50

30

20

Model SSH – 24SH / Size (Tamaño) 11/2 x 21/2-10RPM 2900Curve (Curva) CN0504R00

METERSMETROS

FEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) H

CAPACITY (CAPACIDAD) Q

m3/hr

U.S. GPM

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

240

200

48%

3' NPSHR – FEET (PIES)

53 5557

57

58

6'

8'

10'

53

A 97/8" DIA.

B 91/2"

C 93/16"

D 87/8"

E 89/16"

F 81/4"

90

80

140 160 180806020

10

10 30 50

55

15 HP

10 HP

20 HP

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 97⁄8" 20

B 9½ 15

C 93⁄16 15

D 87⁄8 15

E 89⁄16 10

F 8¼ 10

NOTE: Pump will pass a sphere to ½" diameter.

NOTA: La bomba pasará una esfera a ½" diámetro.

0 20

400

EFF

40 60

Model SSH – 25SH / Size (Tamaño) 2 x 21/2-10RPM 2900Curve (Curva) CN0507R00

CAPACITY (CAPACIDAD) Q

m3/hr

U.S. GPM

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

80

0

50

100

150

250

300

FEETPIES

200

80 120 160 200 240 280 320 360 400

40

70

60

50

30

20

METERSMETROS

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) H

90

80

10

20 HP15 HP

25 HP

30 HP

53%58

6' NPSHR – FEET (PIES)

10'

17'

6061

62

6261

8'B 91/2"

C 91/8"

D 813/16"

E 83/16"F 715/16"G 711/16"

A 97/8" DIA.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 97⁄8" 30

B 9½ 25

C 91⁄8 20

D 813⁄16 20

E 83⁄16 15

F 715⁄16 15

G 711⁄16 15

NOTE: Pump will pass a sphere to 5⁄16" diameter.

NOTA: La bomba pasará una esfera a 5⁄16" diámetro.

PERFORMANCE CURVES – 50 HZ, 2900 RPMCURVAS DE FUNCIONAMIENTO – 50 HZ, 2900 RPM

Page 24: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 24

Commercial WaterGoulds Water Technology

0

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0 20

6005004003002001000

NPSHR – FEET (PIES)

B 83/4"A 91/16" DIA.

D 81/4"

50

700

40 140

E 77/8"

75

70

60

40

30

10

F 71/2"

6'

C 81/2"

60 80 100 120

5040% EFF

Model SSH – 22SH / Size (Tamaño) 21/2 x 3-8RPM 2900Curve (Curva) CN0510R00

METERSMETROS

FEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA

DIN

AMIC

A TO

TAL)

CAPACITY (CAPACIDAD) Q

m3/hr

U.S. GPM

250

225

200

175

150

125

100

H 611/16"

G 71/8"

J 61/2"

50

20

60

65

6567

68

60

50

7' 8'10'

12' 15'

18'

20'

40 HP

30 HP

25 HP20 HP

15 HP

10 HP

0

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0 20

6005004003002001000

NPSHR – FEET (PIES)

B 915/16"

A 103/8" DIA.

D 91/4"

50

700

40 140

E 83/4"

50

300

75

25

0

6'

C 99/16"

60 80 100 120

45% EFF

Model SSH – 27SH / Size (Tamaño) 21/2 x 3-10RPM 2900Curve (Curva) CN0513R00

METERSMETROS

FEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) H

CAPACITY (CAPACIDAD) Q

m3/hr

U.S. GPM

250

200

150

100

400

350

100

25 HP

5560

6568

30 HP

40 HP

50 HP

6869

65

8'10'

12'15'

20'

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 91⁄16" 40

B 8¾ 30

C 8½ 30

D 8¼ 25

E 77⁄8 20

F 7½ 20

G 71⁄8 15

H 611⁄16 15

J 6½ 15

NOTE: Pump will pass a sphere to 19⁄32" diameter.

NOTA: La bomba pasará una esfera a 19⁄32" diámetro.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 103⁄8" 50

B 915⁄16 40

C 99⁄16 40

D 9¼ 30

E 8¾ 30

NOTE: Pump will pass a sphere to 19⁄32" diameter.

NOTA: La bomba pasará una esfera a 19⁄32" diámetro.

PERFORMANCE CURVES – 50 HZ, 2900 RPMCURVAS DE FUNCIONAMIENTO – 50 HZ, 2900 RPM

Page 25: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 25

Commercial WaterGoulds Water Technology

0

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0 40

120010008006004002000

NPSHR – FEET (PIES)

B 811/16"

A 91/16" DIA.

D 81/16"

50

1400

80 280

E 711/16"

50

20060

40

9'

C 87/16"

120 160 200 240

50% EFF

Model SSH – 23SH / Size (Tamaño) 3 x 4-8RPM 2900Curve (Curva) CN0516R00

METERSMETROS

FEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) H

CAPACITY (CAPACIDAD) Q

m3/hr

U.S. GPM

175

150

100

250

225

70

50 HP

60

75

30

20

10

125

F 71/2"

G 71/8"

H 67/8"

J 61/2"

10'

7072

12'

15'

72

74

74

76

7620'

70

40 HP

30 HP25 HP

20 HP15 HP

0

NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0 40

120010008006004002000

NPSHR – FEET (PIES)

D 97/16"

C 913/16" DIA.

F 811/16"

50

1400

80 280

50

300

75

25

0

8'

E 91/16"

120 160 200 240

50% EFF

Model SSH – 28SH / Size (Tamaño) 3 x 4-10RPM 2900Curve (Curva) CN0519R00

METERSMETROS

FEETPIES

TOTA

L DY

NAM

IC H

EAD

(CAR

GA D

INAM

ICA

TOTA

L) H

CAPACITY (CAPACIDAD) Q

m3/hr

U.S. GPM

250

200

150

100

400

350

100

30 HP

60 6570

73

73

7575

9'10'

12'14'

17'

20'

40 HP

50 HP

60 HP

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 91⁄16" 50

B 811⁄16 40

C 87⁄16 40

D 81⁄16 30

E 711⁄16 30

F 7½ 25

G 71⁄8 20

H 67⁄8 20

J 6½ 15

NOTE: Pump will pass a sphere to ½" diameter.

NOTA: La bomba pasará una esfera a ½" diámetro.

Optional Impeller,Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

C 913⁄16" 60

D 97⁄16 50

E 91⁄16 50

F 811⁄16 40

NOTE: Pump will pass a sphere to ¾" diameter.

NOTA: La bomba pasará una esfera a ¾" diámetro.

PERFORMANCE CURVES – 50 HZ, 2900 RPMCURVAS DE FUNCIONAMIENTO – 50 HZ, 2900 RPM

Page 26: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 26

Commercial WaterGoulds Water Technology

SSH FRAME MOUNTED – MATERIALS OF CONSTRUCTIONSSH ARMAZÓN MONTADO – MATERIALES DE CONSTRUCCIÓN

SSH CLOSE COUPLED – MATERIALS OF CONSTRUCTIONSSH ACOPLE CERRADO – MATERIALES DE CONSTRUCCIÓN

Item No., Description, Materials, Parte No. Descripción Materiales

100 Casing, Carcasa

101 Impeller, Impulsor

103 Wear ring, Anillo de desgaste 316L SS, 316L acero inox.

184 Seal housing, Alojamiento del sello

126 Shaft sleeve, Camisa del eje 316 SS, 316 acero inox.

422 Impeller stud, Perno del impulsor Steel, Acero

178 Impeller key, Carbon steel,

Llave del impulsor Acero al carbono

199 Impeller washer, Arandela del impulsor 316 SS, 316 acero inox.

Casing bolt with nut (casing to adapter), 316L SS,

370 Tornillo de la carcasa con tuerca

316L acero inoxidable (carcasa para adaptador)

Cast iron ASTM A48 CL20, 108 Adapter, Adaptador Hierro fundido ASTM A48CL20

Hex head cap screw (adapter to motor), Steel SAE 1200 series,371 Tornillo de cabeza hexagonal Acero SAE series 1200 (adaptador para motor)

412A O-ring, Impeller, Anillo en O, impulsor

412F O-ring, shaft sleeve, Anillo en O, camisa del eje Viton

513 O-ring, Anillo 'O'

408 Drain plug – 3⁄8 BSP, 316L SS,

Válvula de drenaje – 3⁄8 BSP 316 acero inoxidable

383 Mechanical seal, See seal chart,

Sello mecánico Ver tabla del sello

Item No., Description, Materials, Parte No. Descripción Materiales

100 Casing, Carcasa

101 Impeller, Impulsor 316L SS,

103 Wear ring, Anillo de desgaste 316L acero inox.

184 Seal housing, Alojamiento del sello

126 Shaft sleeve, Camisa del eje 316 SS, 316 acero inox.

178 Impeller key, Llave del impulsor Carbon steel,422 Impeller Stud, Perno del impulsor Acero al carbono

199 Impeller washer, Arandela del impulsor 316 SS, 316 acero inox.

370 Casing bolt with nut, Tornillo de la carcasa con tuerca 316L SS,

408 Drain plug – 3⁄8 NPT, Válvula de drenaje – 3⁄8 NPT 316L acero inox.

513 O-ring, Anillo ‘O’ Viton

383 Mechanical seal, See seal chart, Sello mecánico Ver tabla del sello

108 Adapter, Adaptador

228 Bearing frame, Armazón de balineras

134 Bearing cover, Cubierta de balineras

122 Pump shaft, Carbon steel, Eje de la bomba Acero al carbono

168 Ball bearing (inboard), Balineras de bolas (interior)

112 Ball bearing (outboard), Balineras de bolas (exterior)

382 Retaining ring, Anillo de sujeción

Hex head cap screw (adapter to bearing frame),370B Tornillo de cabeza hexagonal Steel, Acero (adaptador para armazón de balineras)

Hex head cap screw (bearing frame to cover), 370C Tornillo de cabeza hexagonal (armazón de balineras para cubierta)

333A Lip seal, Sello cubierto BUNA-N

193 *Grease fitting, Accesorio de grasa Steel, Acero

123 V-ring deflector, Deflector anillo ‘V’ BUNA-N

* M-Group only

Part No.,Pleza Número

10K19 10K20

EPR

Hot Water, 383 Carbon, Silicon 316 SS, Agua Caliente Options,

10K27 10K45 Carbone Carbide, 316 Mild Abrasive,

383 Carburo de Viton

Acero Abrasivo Suave Opciones

10K64 10K65 Sil-Carb. silicona inoxidable Severe Duty,

Deber Severo

Mechanical Seal, Sello MecánicoJohn Crane Type 21 Mechanical Seal,Sello Mecánico John Crane Tipo 21

Item, Rotary, Stationary, Elastomers, Parte Rotativo Estacionario Elastómeros

Cast iron ASTM A48CL20,Hierro fundido ASTM A48CL20

Metal Intended Parts, Duty, Partes Servicio Metálicas Propuesto

103 199 422 408 178

100 101 178 108 370

513

199 422 408 126 371412F

184

383412A

103

383100 101 513 370 184 108 228

126370B 123 168 112 122382

134

370C

333A

412F

412A

180-210 250-360 Frames, Frames, Armazones Armazones

Page 27: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 27

Commercial WaterGoulds Water Technology

SSH – ENGINEERING DATA S-GROUPSSH – INFORMACIÓN TÉCNICA GRUPO-S

Channel Steel Bedplate, Clockwise Rotation Viewed from Drive End;Fundación de Acero, Rotación en Dirección de las Agujas del Reloj Visto desde el Extremo del Motor

NOTES:1. All pumps shipped in vertical dis-

charge position. May be rotated in 90° increments. Tighten 3⁄8 – 16 casing bolts to 12 ft./lbs. torque.

2. Dimensions in inches.3. Motor dimensions may vary with

motor manufacturer.4. Not to be used for construction

purposes.

NOTAS:1. Todas las bombas transportadas

en posición de descarga vertical. Pueden rotarse en aumentos de 90º. Apretar 3⁄8 – 16 tornillos de carcasa a 12 pies/libras potencia.

2. Las dimensiones en pulgadas.3. Las dimensiones puede que varíen

con los fabricantes..4. No para propósitos de construc-

ción.

MotorFrame,

Armazóndel

Motor

Available Motor and Bedplate Dimensions and Weights,Pesos y Dimensiones Disponibles de la Fundación y del Motor

ODP TEFC ODP TEFC ODP TEFC ODP TEFC

Dimensions and weights vary with manufacturers. Dimensions in inches and weights in lbs.* “HP” Dimensions at motor end only.** “HD” Dimension for 254T/256T motor frame on 1 x 2-10 only is 11"; A ¾" motor shim and a 1¾" bearing frame shim are required.

Dimensiones y pesos varían con los fabricantes. Dimensiones en pulgadas y pesos en libras.* Dimensiones “HP” sólo en el extremo del motor.** La dimensión “HD” para el bastidor del motor 254T/256T de 1 x 2 - 10 es sólo 11"; se requieren una cuña del motor de ¾" y una cuña del bastidor de apoyo de 1¾".

HP @ 3500 RPM, HP @ 1750 RPM, Bedplate Data, Datos de la Fundación HP a 3500 RPM HP a 1750 RPM Single Phase, Three Phase, Single Phase, Three Phase, Monofásicos Trifásicos Monofásicos Trifásicos

SUCTIONSUCCIÓN

DISCHARGEDESCARGA

3⁄8" – 19 BSP

KEYWAY 1⁄8 x ¼CHAVETERO 1⁄8 x ¼

HP

SPACER COUPLINGACOPLE DEL ESPACIADOR

COUPLING GUARD, GUARDA ACOPLE1.1251.124

DC MAX.

CREF

(4) HOLES5⁄8 DIA.

(4) AGUJEROS

5⁄8 DIA.

SINGLE PHASE ONLY, SOLO UNIFÁSICOS

ABMAX.

HE HEHA

HG

HD

X

DD

Y ZCP 3¾

PMAX.

HF

HB

HL

PRIME PLUG

DRAIN PLUG

Ø

Motor Bearing HA HB HD** HE HF HG HP* Frame Shim Shim

Dimension “HL” Determined by Pump and Bedplate, Dimensión “HL” determinada la bomba y el motor Motor Frame Size, Tamaño del bastidor del motor Pump, Bomba Suction*, Discharge*, CP DC Max., DD X Y Z Wt. (lbs.), 143/ 183/ 213/ 254/ 284/ Sución* Descarga* DC Máx. Peso (lib.) 145 184 215 256 286 9SH 1 X 2–6

163⁄4 5 4¾ 63⁄8 56

91⁄8 75⁄8 37⁄8 10SH 1 X 2–8 2 1 55⁄8 53⁄8 71⁄8 31⁄8 37⁄8 64

11SH 1 X 2–10 179⁄16 67⁄8 65⁄8 87⁄8 4 86 10 8½ 4¾ 4SH 1½ X 2½–6

1½ 169⁄16 5 4¾ 63⁄8 3¼ 57 9¼ 7¾ 4

7SH 1½ X 2½–8 2½

55⁄8 53⁄8 71⁄8

66 5SH 2 X 2½–6

2

175⁄16 5 4¾

4 35⁄8 57

10 8½ 4¾ 8SH 2 X 2½–8

6 5¾ 715⁄16 68

6SH 2½ X 3–6 3 2½ 59* For use with ANSI Class 150 mating flanges.* Para usar con bridas que casan ANSI clase 150.

Dimensions and Weights – Determined by Pump,Dimensiones y Pesos – Determinados por la Bomba

AB P Wt. Max., CREF Max., Max., AB P Peso Máx. Máx. Máx.

Wt.(lbs.),Peso

(libras)

143T 1 1 1 1 5¼

133⁄8 65⁄8

45 1¾

145T 2 2 2 – 3 2 1½ 1½ 1½ – 2 1½ – 2 14¼ 53 10 28 8 3¾ 24 2¾ ¾ 48 —

182T 3 3 5 3 2 2 3 3 57⁄8

165⁄8 77⁄8

74 ¾

184T 5 5 7½ 5 3 or 5 3 5 3 181⁄8 95

213T 10 7½ 73⁄8

18 95⁄8

116 12 31 8¼ 4¼ 29 3 1 65 — —

215T 15 10 191⁄8 136

254T 20 15 101⁄8

215⁄8 13

266 13 42 10¼ 5¼ 38½ 4 110 — 1

256T 25 20 233⁄8 264 1¾

284TS 30 25 125⁄8

247⁄8 15

392 15 44 10½ 5¾ 40½ 3½ 124 – 1¾

286TS 40 30 265⁄8 432

Page 28: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 28

Commercial WaterGoulds Water Technology

Channel Steel Bedplate, Clockwise Rotation Viewed from Drive End;Fundación de Acero, Rotación en Dirección de las Agujas del Reloj Visto desde el Extremo del Motor

Three Phase, Single Phase, Three Phase, Trifásicos Monofásicos Trifásicos

MotorFrame,

Armazóndel

Motor

HA HB HD HE HF HG

HP @ 3500 RPM HP @ 1750 RPM – T-Frame Only Bedplate Data, Datos de la Fundación AB P Wt. Max., C Max., Max., AB Ref. P Peso Máx. Máx. Máx.

Available Motor and Bedplate Dimensions and Weights,Pesos y Dimensiones Disponibles de la Fundación y del Motor

Wt.(lbs.),Peso

(libras)

DD L X Y

24SH 1½ x 2½-10

2½ 1½

67⁄8 65⁄8 125

25SH 2 x 2½-10 2 23

101⁄8

815⁄16 4 125

22SH 2½ x 3-8 3

2½ 61⁄8 57⁄8 125

27SH 2½ x 3-10 67⁄8 65⁄8

915⁄16

134

23SH 3 x 4-8 4 3 24

111⁄8

5 136

28SH 3 x 4-10 75⁄8 73⁄8 111⁄8 148

CP

Dimensions and Weights – Determined by Pump,Dimensiones y Pesos – Determinados por la Bomba

NOTE:1. Pumps will be shipped with top verti-

cal discharge as standard. For other orientations, remove casing bolts, rotate discharge to desired position and tighten 3⁄8 – 16 bolts to 12 ft./lbs.

2. ALL dimensions in inches.3. Not for construction purposes.

NOTA:1. Las bombas se transportarán con

la descarga vertical superior como estándar. Para otras orientaciones, retirar los tornillos de la carcasa, ro-tar la descarga a la posición deseada, y apretar 3⁄8 – 16 tornillos a 12 pies/libras.

2. TODAS las dimensiones en pulgadas.3. No para propósitos de construcción.

Wt.(lbs.),Peso

(libras)

Suction*, Discharge*, Succión* Descarga*

Pump Size,Tamaño de la Bomba

Dimensions and weights vary with manufacturers. Dimensions in inches and weights in lbs.Dimensiones y pesos varían con los fabricantes. Dimensiones en pulgadas y pesos en libras.

* For use with ANSI class 150 mating flanges.* Para usar con bridas que casan ANSI clase 150.

DCMax.,

DCMáx.

184T 3 or 5 3 5 5 57⁄8 181⁄8 77⁄8 95

213T 7½ 7½ 73⁄8

18 95⁄8

116

215T 15 10 10 191⁄8 136 13 42 101⁄4 51⁄4 38½ 4 111

254T 20 15 15 15 91⁄2

215⁄8 13

266

256T 25 20 20 20 233⁄8 264

284TS/T 30 25 25 25 125⁄8

247⁄8 15

392 15 44 10½ 5¾ 40½ 3½ 124

286TS/T 40 30 265⁄8 422

324TS/T 50 40 141⁄8

283⁄4 173⁄8

592 12

326TS/T 60 50 30¼ 634 18 48

7¼ 44½ 4 183

364TS/T 75 60 151⁄8

315⁄8 187⁄8

834 13

365TS/T 100 75 325⁄8 1000

405TS/T 100 18 367⁄8 205⁄8 1060 22 56 14 7¼ 52½ 4 214

ODP TEFC ODP TEFC ODP TEFC

Pump

ABMAX.

PRIME PLUG

HE HE

HA

DRAINPLUG

HG

HD

SUCTION

DISCHARGE

DCMAX.

3/8” GAS THREADUNI ISO 228/1

DD

CP

Y

L

HB

HF

4 HOLES5 ∨8

13∨4

PMAX.

C REF.

3 3∨4

1.6251.624

3 7∨8

SPACER COUPLING

COUPLING GUARD

SINGLE PHASEONLY

KEYWAY3/16 X 3/8

415∨16

3⁄8" – 19 BSP

SSH-F – ENGINEERING DATA M-GROUPSSH-F – INFORMACIÓN TÉCNICA GRUPO-M

Page 29: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 29

Commercial WaterGoulds Water Technology

(All dimensions in inches and weights in lbs. Do not use for construction purposes.)(Todas las dimensiones en pulgadas y pesos en libras. No usar para propósitos de construcción.)

Motor Frame Selections,Selecciones del Armazón del Motor

DISCHARGEDESCARGA

SUCTIONSUCCIÓN

DC MAX.G

H-(4) HOLESH-(4) AGUJEROS

DD X Y Z 143/145 182/184 213/215 254/256 9SH 1 x 2 – 6 5 4¾ 63⁄8 31⁄8

93⁄8 10½ 11½ —

24 10SH 1 x 2 – 8 2 1 55⁄8 53⁄8 71⁄8 37⁄8 32 11SH 1 x 2 – 10 67⁄8 65⁄8 87⁄8 4 10¾ 113⁄8 123⁄8 125⁄8 54 4SH 1½ x 2½ – 6

1½ 5 4¾ 63⁄8 3¼ 9¾ 103⁄8 113⁄8 — 25

7SH 1½ x 2½ – 8 2½

55⁄8 53⁄8 71⁄8 34 5SH 2 x 2½ – 6

2 5 4¾ 71⁄8 4 35⁄8 10½ 111⁄8 121⁄8 123⁄8

25 8SH 2 x 2½ – 8

6 5¾

715⁄16 36

6SH 2½ x 3 – 6 3 2½ 4¾ 27

3⁄8" – 19 BSP

NOTE:1. Pumps shipped in vertical discharge

as standard. For other orientations, remove casing bolts, rotate discharge to desired position, and tighten 3⁄8 – 16 bolts to 12 ft./lbs., 7⁄16 – 14 bolts to 20 ft./lbs.

2. ALL dimensions in inches.3. Motor dimensions may vary with mo-

tor manufacturer.4. Not for construction purposes.

NOTA:1. Las bombas se transportarán en

descarga vertical como estándar. Para otras orientaciones, retirar los tornillos de la carcasa, rotar la descarga a la posición deseada, y apretar 3⁄8 – 16 tornillos a 12 pies/libras, 7⁄16 – 14 tornillos a 20 pies/libras.

2. TODAS las dimensiones en pulgadas.3. Las dimensiones puede que varíen con

los fabricantes.4. No para propósitos de construcción.

Pump,Bomba

DCMax.,

DCMáx.

Dimensions Determined by JM Motor Frame, Dimensiones Determinadas por el Armazón del Motor JM

Suct.*, Disch.*, Succ.* Desc.*

150 lb. Flange,Brida de 150 lib. DIM. “L” (Motor Frame Size)

DIM. “L” (Tamaño del Armazón del Motor)Wt.

(lbs.),Pesos

(libras)

* For use with ANSI class 150 mating flanges.* Para usar con bridas que casan ANSI clase 150.

ODP TEFC ODP TEFC ODP TEFC ODP TEFC 143JM – – – – – – 1 1 145JM 2 2 2-3 2 1-1½ 1-1½ 1½-2 1½-2 182JM 3 3 5 3 2 2-3 3 3 184JM 5 5 7½ 5 3 – 5 5 213JM 7½ – 10 7½ 5 – 7½ 7½ 215JM 10 – 15 10-15 – – – – 254TCZ – – 20 – – – – – 256TCZ – – 25 20 – – – –

1Ø, Monofásicos 3Ø, Trifásicos 1Ø, Monofásicos 3Ø, Trifásicos

Motor Horsepower, Potencia del Motor 3500 RPM, 3500 RPM 1750 RPM, 1750 RPM

Motor Frame,

Armazón del Motor 143JM

6½ 5¼ 6 3½ 2¾ 2 1⁄8 11¼ 11⁄32 65⁄8

41 145JM 2½ 57 182JM

8½ 67⁄8 6½ 4½ 3¾ 2¼ 3⁄16 13½

77⁄8

77 184JM

13⁄32 97

213JM 9½ 73⁄8 8 5¼ 4¼

7⁄32 15½

95⁄8 122

215JM 3½ 155 254TCZ

11¼ 9 9½

6¼ 5 41⁄8 ¼ 185⁄8 17⁄32 11½

265 256TCZ 11¾ 5 320

A AB B D E F G CREF

JM Frame,JM

Armazón

PMax.,

PMáx.

HDia.,

HDiám.

Motor Wt.(lbs.)

Peso Motor(lib.)

AB MAX.

X

D

E EA

DD

PMAX.

F FB

L

Y Z CREF

DRAIN PLUG

PRIME PLUG

SSH CLOSE COUPLED – DIMENSIONS AND WEIGHTS S-GROUPSSH ACOPLE CERRADO – DIMENSIONES Y PESOS GRUPO-S

Page 30: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 30

Commercial WaterGoulds Water Technology

140 180 210 250 280 320 360

PRIME PLUG

DRAIN PLUG

D

A

SUCTION

DISCHARGE Y

CP

L

DCMAX.

3/8-19 BSP

DD

E

AB MAX.

E

G

MAX.

BF F

P MAX.

H-4 HOLES

415/16

(All dimensions in inches and weights in lbs. Do not use for construction purposes.) (Todas las dimensiones en pulgadas y pesos en libras. No usar para propósitos de construcción.)

A B D E F G HFrame, Armazón

364TCZ and 365TCZ frames are built with 326JM shaft extensions.Dimensions may vary with manufacturer.Los armazones 364TCZ y 365TCZ se construyen con extensiones del eje 326JM. Las dimensiones puede que varíen con los fabricantes.

P Max.,P Máx.

364TCZ and 365TCZ frames are built with 326JM shaft extensions.Los armazones 364TCZ y 365TCZ se construyen con extensiones del eje 326JM.

Motor Frame Selections,Selecciones del Armazón del Motor

Motor Horsepower, Potencia del Motor Wt.Max.,PesoMáx.

ODP TEFC ODP TEFC ODP TEFC 145JM – – – – 2 2 57 182JM – – 2 2, 3 3 3 77 184JM – – 3 – 5 5 97 213JM 10 – 5 – 7½ 7½ 141 215JM 15 10 – – 10 10 155 254JM 20 15 – – 15 15 265 256JM 25 20 – – 20 20 320 284JM 30 25 – – 25 25 419 286JM 40 30 – – – – 422 324JM 50 40 – – – – 562 326JM 60 50 – – – – 625 364TCZ 75 60 – – – – 775 365TCZ 100 75, 100 – – – – 905

3500 RPM 1750 RPM

Frame,Armazón 3 PH, Trifásicos 1 PH, Monofásicos 3 PH, Trifásicos

Dimensions “L” Determined by Pump and Motor, Dimensiones “L” Determinadas por la Bomba y el Motor

Motor Frame Size,Tamaño del Armazón del Motor

* For use with ANSI class 150 mating flanges.* Para usar con bridas que casan ANSI clase 150.

145JM 6½ 5¼ 6 3½ 2¾ 2½ 1⁄8 11⁄32 73⁄16

182JM 8½ 57⁄8 6½ 4½ 3¾

2¼ 3⁄16 8½ 184JM

2¾ 13⁄32

213JM

9½ 73⁄8 8 5¼ 4¼ 7⁄32 103⁄16

215JM 3½ 254JM

11¼ 9 11¾ 6¼ 5 41⁄8

13¼ 256JM 5

¼ 17⁄32 284JM

12¼ 12¼ 12¼ 7 5½ 4¾

15 286JM 5½ 324JM

14 13¼ 14 8 6¼ 5¼ 5⁄16 1615⁄16

326JM 6 21⁄32 364TCZ

17¾ 151⁄8 15½ 9 7 55⁄8

1 19 365TCZ 61⁄8

Dimensions Determined by JM Motor Frame, Dimensiones Determinadas por el Armazón del Motor JM

DD X Y

Wt.(lbs.),Peso

(libras)

Suction*, Discharge*, Succión* Descarga*

Pump Size,Tamaño de la Bomba

DCMax.,

DCMáx.

Pump

NOTAS:1. Las bombas se transportarán en descarga vertical

como estándar. Para otras orientaciones, retirar los tornillos de la carcasa, rotar la descarga a la posición deseada, y apretar 3⁄8 – 16 tornillos a 12 pies/libras, 7⁄16 – 14 tornillos a 20 pies/libras, ½ – 13 tornillos a 35 pies/libras.

2. TODAS las dimensiones en pulgadas.3. No para propósitos de construcción.

NOTES:1. Pumps shipped in vertical discharge as standard.

For other orientations, remove casing bolts, rotate discharge to desired position, and tighten 3⁄8 – 16 bolts to 12 ft./lbs., 7⁄16 – 14 bolts to 20 ft./lbs., ½ – 13 bolts to 35 ft./lbs.

2. Motor dimensions may vary with motor manufacturer.

3. Not for construction purposes.

24SH 1½ x 2 ½-10 2½

1½ 34½ 67⁄8 65⁄8

75 10½ —

25SH 2 x 2½-10 2 815⁄16 4 75 111⁄8

22SH 2½ x 3-8 3 2½

36 61⁄8 57⁄8 72 — 121⁄8 137⁄8 143⁄8

15

27SH 2½ x 3-10 67⁄8 65⁄8 915⁄16

84 — —

23SH 3 x 4-8 4 3 37

5 86 11½ 121⁄8

133⁄8 147⁄8 153⁄8 16 28SH 3 x 4-10 75⁄8 73⁄8 111⁄8 98 — —

ABMax.

CPMax.,

CPMáx.

SSH CLOSE COUPLED – DIMENSIONS AND WEIGHTS M-GROUPSSH ACOPLE CERRADO – DIMENSIONES Y PESOS GRUPO-M

Page 31: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 31

Commercial WaterGoulds Water Technology

DC MAX.

3⁄8" – 19 BSP

½¾

KEYWAY 1⁄8 x ¼, CHAVETERO 1⁄8 x ¼

1.1251.124 DIA.

Dimensions and Weights – Bare Pump Only,Dimensiones y Pesos – Solamente Bomba

9SH 1 x 2 – 6 5 4¾

163⁄4 77⁄8 63⁄8 31⁄8

56

10SH 1 x 2 – 8 2 1 55⁄8 53⁄8 71⁄8 37⁄8 64

11SH 1 x 2 – 10 67⁄8 65⁄8 179⁄16 8¾ 87⁄8 4 86

4SH 1½ x 2½ – 6 1½

5 4¾ 169⁄16 7¾ 63⁄8 3¼ 57

7SH 1½ x 2½ – 8 2½

55⁄8 53⁄8 71⁄8

65

5SH 2 x 2½ – 6 2 5 4¾

175⁄16 8½

4 35⁄8 57

8SH 2 x 2½ – 8 6 5¾

715⁄16

68

6SH 2½ x 3 – 6 3 2½ 59

Pump,Bomba

NOTE: 1. Pumps will be shipped

with top vertical discharge as standard. For other orientations, remove casing bolts, rotate discharge to desired position, and tighten 3⁄8 –16 bolts to 12 ft./lbs., 7⁄16 – 14 bolts to 20 ft./lbs.

2. ALL dimensions in inches.3. Not for construction

purposes.

NOTA: 1. Las bombas se

transportarán con la descarga vertical superior como estándar. Para otras orientaciones, retirar los tornillos de la carcasa, rotar la descarga a la posición deseada, y apretar 3⁄8 – 16 tornillos a 12 pies/libras, 7⁄16 – 14 tornillos a 20 pies/libras.

2. TODAS las dimensiones en pulgadas.

3. No para propósitos de construcción.

Wt.(lbs.),Peso

(libras)

DD L X Y ZDC

Max.,DC

Máx. Suction*, Discharge*, Succión* Descarga*

150 lb. Flange,Brida de 150 lib. CP

Max.,CP

Máx.

7

2¾ 2¾

X

DD

PRIME PLUG

DRAIN PLUG L 5

ZY

CPDISCHARGEDESCARGA

SUCTIONSUCCIÓN

* For use with ANSI class 150 mating flanges.* Para usar con bridas que casan ANSI clase 150.

7⁄16 DIA. – (4) HOLES7⁄16 DIA. – (4) AGUJEROS

SSH FRAME MOUNTED – DIMENSIONS AND WEIGHTS S-GROUPSSH ARMAZÓN MONTADO – DIMENSIONES Y PESOS GRUPO-S

Page 32: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 32

Commercial WaterGoulds Water Technology

Dimensions and Weights – Bare Pump Only,Dimensiones y Pesos – Solamente Bomba

* For use with ANSI class 150 mating flanges.* Para usar con bridas que casan ANSI clase 150.

DD L X Y

24SH 1½ x 2½-10

2½ 1½

67⁄8 65⁄8 125

25SH 2 x 2½-10 2 23

10¼

815⁄16 4 125

22SH 2½ x 3-8 3 2½

61⁄8 57⁄8 125

27SH 2½ x 3-10 67⁄8 65⁄8

915⁄16

134

23SH 3 x 4-8 4 3 24

11¼

5 136

28SH 3 x 4-10 75⁄8 73⁄8 111⁄8 148

CP

Wt.(lbs.),Peso

(libras)

Suction*, Discharge*, Succión* Descarga*

Pump Size,Tamaño de la Bomba

DCMax.,

DCMáx.

Pump

NOTES: 1. Pumps will be shipped with top vertical discharge as standard.

For other orientations, remove casing bolts, rotate discharge to desired position, replace and tighten 3⁄8 –16 bolts to 12 ft./lbs.

2. Motor dimensions may vary with motor manufacturer.3. Not for construction purposes.

NOTAS: 1. Las bombas se transportarán con la descarga vertical

superior como estándar. Para otras orientaciones, retirar los tornillos de la carcasa, rotar la descarga a la posición deseada, y apretar 3⁄8 – 16 tornillos a 12 pies/libras.

2. TODAS las dimensiones en pulgadas.3. No para propósitos de construcción.

PRIME PLUG

DRAIN PLUG

SUCTION

DISCHARGE Y

CP

L

DCMAX.

3/8" – BSP

DD

1"

KEYWAY3/16 X 3/8

4 HOLES9/ 16 D IA .

1.6251.624

DIA.

415/16

81/2

61/2

1∨2

37/8

61/4

81/2

31/231/2

SSH FRAME MOUNTED – DIMENSIONS AND WEIGHTS M-GROUPSSH ARMAZÓN MONTADO – DIMENSIONES Y PESOS GRUPO-M

Page 33: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 33

Commercial WaterGoulds Water Technology

SPECIFICATIONSESPECIFICACIONES

Capacities to: 1100 GPM (250 m3/hr) at 3500 RPM 775 GPM (177 m3/hr) at 1750 RPM

Heads to: 525 feet THD (158 m) at 3500 RPM130 feet THD (40 m) at 1750 RPM

Maximum working pres-sures to: 230 PSI (15 bars)

Maximum temperatures to: 250°F (121°C)

All wetted components of AISI: Type 316L stainless steel material.

Rotation: Clockwise when viewed from motor end.

Enclosed impeller and replaceable wear ring:for high efficiency and maxi-mum wear life.

Motor (close coupled):NEMA standard JM shaft open drip-proof, totally enclosed and explosion-proof enclosures, 60 Hz, 1750 or 3500 RPM.Single phase ODP (115/230 V) 1750 RPM, 1 – 5 HP.Three phase ODP. TEFC/Exp. proof (208 – 230/460 V). 3500 RPM, 2 – 100 HP 1750 RPM, 1 – 25 HP

NOTE: Overload protection must be provided. Contac-tor with overload for single phase or starter with heat-ers for three phase ordered separately.

Motor (frame mounted): NEMA standard T-frame open drip-proof, totally enclosed and explosion-proof (three phase only) enclosures 60 Hz, 1750 or 3500 RPM.Single phase (115/230 V) 1750 RPM, 1 – 5 HPThree phase (208 – 230/ 460 V) 3500 RPM, 3 – 125 HP 1750 RPM, 1 – 25 HP

NOTE: Overload protection must be provided. Contac-tor with overload for single phase or starter with heat-ers for three phase ordered separately.

Optional: Rigid carbon steel bedplate, sheet metal coupling guard designed to OSHA specifications and T.B. WOODS type “SC” spacer couplings.

Capacidades:1100 GPM (105 m 3/hr) a 3500 RPM 775 GPM (177 m3/hr) a 1750 RPM

Cargas:525 pies THD (158 m) a 3500 RPM 130 pies THD (40 m) a 1750 RPM

Presión de trabajo máxima:230 PSI (15 baras)

Temperatura máxima:250°F (121°C)

Todos los componentes mojados de AISI: Material de acero inoxidable tipo 316L.

Rotación: En dirección de las agujas del reloj visto desde el extremo final del motor.

Impulsor encerrado y anillo de desgaste reem-plazable: para alta eficien-cia y máxima durabilidad.

Motor (acople cerrado): Eje a prueba de goteo JM estándar NEMA, totalmente encerrado y recintos a prueba de explosión, 60 Hz, 1750 ó 3500 RPM.Unifásicos ODP (115/230 V) 1750 RPM, 1 – 5 HP Trifásicos ODP. TEFC/a prueba de explosión (208 – 230/ 460 V). 3500 RPM, 2 – 100 HP 1750 RPM, 1 – 25 HP

NOTA: Se debe de propor-cionar protección térmica contra sobrecarga. Contactor con protección térmica contra sobrecarga para unifásicos o arrancadores con calentadores para trifásicos se piden por separado.

Motor (armazón mon-tado): Armazón abierto T a prueba de goteo estándar NEMA, totalmente encerrado y recintos a prueba de ex-plosión (trifásicos solamente) 60 Hz, 1750 ó 3500 RPM.Unifásicos (115/230 V) 1750 RPM, 1 – 5 HP.Trifásicos (208 – 230/460 V) 3500 RPM, 3 – 125 HP 1750 RPM, 1 – 25 HP

NOTA: Se debe de propor-cionar protección térmica contra sobrecarga. Contactor con protección térmica contra sobrecarga para unifásicos o arrancadores con calentadores para trifásicos se piden por separado.

Opcional: Fundación rígida de acero al carbono, guarda acople de metal laminado diseñado según las especifi-caciones OSHA y acoples del espaciador T.B. WOODS tipo “SC”.

Page 34: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 34

Commercial WaterGoulds Water Technology

Specifically designed for all traditional cast iron or bronze fitted water and low grade corrosive services.

• Watercirculation

• Boostersystems

• Liquidtransfer

• HVACpumpreplacements

• Generalservicepumping

TYPICAL APPLICATIONSAPLICACIONES TÍPICAS

Water truck,Camión cisterna

HVAC,Calefacción, Ventilación y Aire Acondi-cionado

Diseñada específicamente para to-dos los servicios de agua de hierro fundido o recubiertas de bronce y servicios corrosivos de bajo grado.

• Circulación de Agua

• Aumento de presión

• Transferencia de líquidos

• Reemplazos para bombas HVAC

• Bombeo de servicios generales

Tubing washer,Arandela de tubería

Reverse osmosis,Ósmosis invertida

PCB washer,Arandela PCB

Textile dyes,Colorantes textiles

Boiler feed,Alimentación de caldera

Page 35: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

PAGE 35

Commercial WaterGoulds Water Technology

NOTESNOTAS

Page 36: G&L Series SSH - hamiltonengineering.comhamiltonengineering.com/pdf/Goulds SSH.pdf · John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Impeller Option Code

Goulds is a registered trademark of Goulds Pumps, Inc. and is used under license.© 2012 Xylem Inc. BSSH March (Marzo) 2012

Xylem, Inc.2881 East Bayard Street Ext., Suite ASeneca Falls, NY 13148Phone: (800) 453-6777 Fax: (888) 322-5877www.xyleminc.com/brands/gouldswatertechnology

1) The tissue in plants that brings water upward from the roots;2) a leading global water technology company.

We’re 12,000 people unified in a common purpose: creating innovative solutionsto meet our world’s water needs. Developing new technologies that will improvethe way water is used, conserved, and re-used in the future is central to our work.We move, treat, analyze, and return water to the environment, and we help peopleuse water efficiently, in their homes, buildings, factories and farms. In more than150 countries, we have strong, long-standing relationships with customers whoknow us for our powerful combination of leading product brands and applicationsexpertise, backed by a legacy of innovation.

For more information on how Xylem can help you, go to www.xyleminc.com

1) El tejido en las plantas que hace que el agua suba desde las raíces;2) una compañía líder global en tecnología en agua.

Somos 12.000 personas unificadas por un propósito en común: crear soluciones innovadoras para satisfacer las necesidades de agua de nuestro mundo. Desarrollar nuevas tecnologías que mejorarán la manera en que se usa, se conserva y se reutiliza el agua en el futuro es un aspecto crucial de nuestra labor. Transportamos, tratamos, analizamos y retornamos el agua al medio ambiente, y ayudamos a las personas a usar el agua de manera eficiente, en sus casas, edificios, fábricas y campos. En más de 150 países, tenemos relaciones sólidas desde hace mucho tiempo con clientes que nos conocen por nuestra potente combinación de marcas de producto líderes y conocimientos de aplicación, con el respaldo de nuestro legado de innovación.

Para obtener más información, visite xyleminc.com.

Xylem

Xylem