RTU as a part of substation automation together with Relion®
Georg Neise, Remote Control, 6 October 2010
Agenda
Overview Relion®
ABB Stationautomationsystem SAS600
Application RTU560 proxy-server
IEC 61850 Tools
SVC – system test IEC 61850
RTU560 hybrid solution for migration
Summary
Relion®
The new family for protection and control
One family for all applications of transmission and distribution grids
Common look & feel for all series
Scalable and flexible according field of application and functionality
One common tool for the whole family
Standard Ethernet interface for parameter setting
Designed for IEC 61850 – full GOOSE performance
615 series
650 series
630 series
670 series
Relion®
The new family for protection and control
Distribution TransmissionSub-transmission
Substation Automation Solutions SAS 600 series
SAS600 – standardized solutions for substation automation Integration of Bay level
solutions Distributed Functionality Open connectivity (connection to
remote control center, integration of 3rd party IEDs)
Future-proof concepts with unrivaled flexibility, modularity and performance
Ensure easy future extension
SAS 600 Series – SAS Solution Portfolio based on IEC 61850
ABB’s Substation Automation System SAS Solutions Positioning
Availability
Functionality
Performance
System Size
SAS 610…SAS 690
IEC 61850-8-1
Station PC
GatewayStation
HMI
SAS 605
IEC 61850-8-1 I/Os
RTUWEB HMI
SAS 635
IEC 61850-8-1
RTUStation
PC/HMI
COM 600
IEC 61850-8-1
RTU560 DIN rail
IEC 61850-8-1 I/Os
Distribution TransmissionSub-transmission
ABB’s Substation Automation System IEC 61850 – Backbone of ABB‘s substation automation
IEC 61850-8-1
The communication standard IEC 61850 is the core technology of ABB‘s substation automation A common and consistent communication platform for protection
and control, for simple and complex solutions, today and in future
Usage of the most powerful communication technology Real-time transfer of binary and analogue data within
milliseconds ABB – collaborate in the IEC 61850 from the start and set standards
ABB’s Substation Automation System Example base solution SAS605
Base solution for new and retrofit projects Modular and centralized
RTU560 based station computer
Direct I / O boards Support of a large number of
protocols for IED integration and remote communication
Integrated WEB server with base functionality for local control
Focus on remote control, optional basic local control
ABB’s Substation Automation System Example enhanced solution SAS635
Flexible solution for new and retrofit projects Distributed station level
devices RTU560 based gateway Support of a large number
of protocols for IED integration and remote communication
Highly reliable remote control and advanced local control functionality
ABB’s Substation Automation System Example RTU DIN rail based SAS
Compact low end solution for small distribution applications Centralized compact DIN rail
mountable RTU560 Connection of I/O modules Supports various protocols
for IED integration (IEC 61850, IEC 103, DNP3.0 and Modbus)
Focus on remote control
IEC60870-5-101, IEC60870-5-104,
DNP3, DNP3 over WAN
Integrated HMIDiagnosis ArchivePLC functions
IEC 61850-8-1
PLCfunctions
IEC-103,
DNP3.0,
Modbus
I/Os
SAS600 - Components IEC 61850 Proxy
Cost effective, flexible and compact DIN rail solution
Client-Server functionality according IEC 61850
Connects legacy protocols and hardwired information to the IEC61850 station bus
PLC functions
Supported Master Protocols IEC 60870-5-101 DNP3.0 Modbus and many more
PLC
RTU I/Os IED‘s
IEC 60870-5-103, SPA, …
IEC 61850
I/Os
IEC 61850 tools from ABB Innovation for the engineering in future
ITT600 SA Explorer
RTUtil 560 station level engineering
Fast and efficient also for bigger projects
PCM600 Engineering Pro One Tool for all devices of ABB Relion®-Family and
system engineering according to he standard
IEC 61850ITT600 system diagnosis
No chance for communication errors
because of transparency and intelligence
ABB’s Substation Automation System SVC – System Verification Center
ABB test lab SVC in Baden (Switzerland) beside KEMA and Nari one of only three certified test labs worldwide
Improve the quality of the system solution and products
Verifying the interoperability and performance in systems of ABB‘s and 3rd party devices
Granting devices with proven system suitability
Basis to ensures the quality of projects from engineering to commissioning
Project example for migration MVV Energie AG, 110-/20-kV substation UW8
2 x line bay 110kV1x bus coupler
( REC216 / REL316 )2 x transformer bay 110/20kV
( REC216 / RET316 / REL316/REC316 )
network control center
40 x bay 20kV( SCU / REL316 )
LON - bus
Indactic 21workstation(MicroSCADA)
LON - bus
Substation 5x 110-kV bays 40x 20-kV-bays SAS based on
LON-bus
Customer‘s requirements Replacement by actual,
future-proof technics Step-by-step realization
during the next years Modernisation without
interruption of energy supply
Comm on
… …
REB500
Solution Step-by-step retrofit, IEC
61850 conform, integration of 3rd party devices
1st step Replacement of station
level devices by RTU560 Local control with
RTU560 integrated HMI
IED conversion to SPA- bus
Connection of NCC with IEC 60870-5-101
Integration of a-eberle voltage regulator with IEC 61850
Project example for migration MVV Energie AG, 110-/20-kV substation UW8
2 x line bay 110kV1x bus coupler
( REC216 / REL316 )2 x transformer bay 110/20kV
( REC216 / RET316 / REL316/REC316 )40 x bay 20kV
( SCU / REL316 )REB500
IEC 61850
RTU560 per voltage level- PLC for interlocking
SPA - bus
TCP/IP19”-Monitor, Maus, Tastatur
PC
binary I/O
SPA - bus
binary I/O
network control centerserviceIEC 60870-5-101
workstation(Integrated HMI RTU560)
… …
2nd step Step-by-step replacement
of IEDs by actual Relion® 630 series with IEC 61850
Potential for savings by usage of combined protection and control IEDs
Customer‘s benefit Sustainable migration by
selective retrofit Easy migration to modern
technologies Maximum safety of
operation and efficient maintenance
Future-proof
RTU560 per voltage level- PLC for interlocking
TCP/IP19”-Monitor, Maus, Tastatur
PC
binary I/O
binary I/O
network control centerserviceIEC 60870-5-101
workstation(Integrated HMI RTU560)
… … …
IEC 61850-8-1
IEC 61850-8-1 Ringkonfiguration
REB5002 x line bay 110kV
1x bus coupler( REF630 )
2 x transformer bay 110/20kV ( REF630 / REGsys )
40 x bay 20kV( new: REF630, old: SCU / REL316 )
SPA - BUS
Project example for migration MVV Energie AG, 110-/20-kV substation UW8
Summary SAS 600 solutions
ABB’s SA Solutions
State-of-the-art solutions based on ABB‘s experience in the area of substation automation and the standard IEC61850
Designed for maximum security, efficiency and reliability
Scalable functionality and architecture, from basic to advanced solution, from single to fully redundant configuration
Ready made solutions: pre-engineered, pre-documented and pre-tested