genset/ generator set 1400kva

2
General Genset Type : TNK1400C Rating : 1120kW / 1400kVA (Prime Power) : 1340kW / 1675kVA (Standby Power) Fuel Consumption : 289 l/h (Prime Power), 345 l/h (Standby Power) Rating Definition Limited-Time Running Power (LTP): Applicable for supplying power to a constant electrical load for limited hours. Limited-Time Running Power (LTP) is in accordance with ISO 8528. Prime Power (PRP): Applicable for supplying power to varying electrical load for unlimited hours. Prime Power (PRP) is in accordance with ISO 8528. Ten percent overload capability is available in accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514. Engine Data Type : CUMMINS KTA50-GS8 Speed [Rpm] : 1500 Frequency (Hz) : 50 No of cylinders : 16 (V) Displacement [l] : 50.3 Bore/Stroke [mm] : 158.8 / 158.8 Compression Ratio : 14.9 : 1 Governor : Electronic Oil Capacity [l] : 204 Alternator Data Type : STAMFORD PI734C : [3Ph, Single Bearing] Rated Output [kVA] : 1400 Speed [Rpm] : 1500 Frequency [Hz] : 50 Voltage [V] : 400/230 Insulation : Class H Protection : IP 23 Specification, picture, dimension may change without notice due to product improvement.

Upload: benry-aprianto-hutapea

Post on 20-Mar-2017

14 views

Category:

Engineering


6 download

TRANSCRIPT

Page 1: Genset/ Generator Set 1400KVA

General Genset Type : TNK1400C Rating : 1120kW / 1400kVA (Prime Power) : 1340kW / 1675kVA (Standby Power) Fuel Consumption : 289 l/h (Prime Power), 345 l/h (Standby Power)

Rating Definition Limited-Time Running Power (LTP): Applicable for supplying power to a constant electrical load for limited hours. Limited-Time Running Power (LTP) is in accordance with ISO 8528.

Prime Power (PRP): Applicable for supplying power to varying electrical load for unlimited hours. Prime Power (PRP) is in accordance with ISO 8528. Ten percent overload capability is available in accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514.

Engine Data Type : CUMMINS KTA50-GS8 Speed [Rpm] : 1500 Frequency (Hz) : 50 No of cylinders : 16 (V) Displacement [l] : 50.3 Bore/Stroke [mm] : 158.8 / 158.8 Compression Ratio : 14.9 : 1 Governor : Electronic Oil Capacity [l] : 204

Alternator Data Type : STAMFORD PI734C : [3Ph, Single Bearing] Rated Output [kVA] : 1400 Speed [Rpm] : 1500 Frequency [Hz] : 50 Voltage [V] : 400/230 Insulation : Class H Protection : IP 23

Specification, picture, dimension may change without notice due to product improvement.

Page 2: Genset/ Generator Set 1400KVA

Cooling System and AccessoriesRadiator Cooling : as Cummins standardCoolant Capacity [l] : 165 Starting Volt. : 24V Exhaust System : Industrial / residential exhaust silencer Baseframe : Steel Channel/Plate construction Engine and Alternator Mounting : Rubber metal elements Set of Operation books, consist of : Engine operating instruction : Certificate of Origin : Alternator operating instruction : Genset Test Report Genset Controller Genset Dimension and Dry Weight Open Type Dimension [LxWxH] : 5420x2140x2500(mm) Dry Weight : 11450(kg)

Silent Type Dimension [LxWxH] : 12192x3100x4000(mm) Dry Weight : 18450kg

PT. Tan Energy Indonesia (TANEKO) Jl. Prof, DR. Latumenten kav.50 Sentra Latumenten blok. D2, Jakarta 11460 Telp : 62-21 569 58610-14 Email : [email protected] Website : www.taneko.co.id

According to ISO 8528-5. Continuous Power: No time limitation, plus 10% addictional, power for governing purpose only. Prime Power: Average output ≤ 80%, no time limitation, plus 5% addictional power for governing purpose only. Limited Time Running Power: for up to 500 h/year, thereof a maximum of 300 h/year continuous running. In consideration of a generator

efficiency level of 89% - 90% and a power factor of 0.8

OPEN TYPE SILENT TYPE (Container 40ft)

DSE7320 Auto Mains (Utility) Failure Control Modules The DSE7320 is a feature packed Auto Mains (Utility) Failure Control Module designed to control single diesel or gas gen-set applications. KEY FEATURES -3-phase generator and mains (utility) sensing -Power monitoring (kW h, kV Ar, kV Ah, kV Ar h) -Remote communications (RS232 & RS485) -Configurable inputs/outputs (9/8) -Fuel usage monitor and low level alarms -Manual/automatic load transfer. - Power save mode. -DSE Configuration Suite PC Software. -etc