generators - kiporuk portable series.pdf · kd09 1 single phase kg140 40×30 0.03768 8.5∶1...

46
T 86-510-85205041 F 86-510-85203796 www.kipor.com No.1098,Dacheng Road, AnZhen, East Park, Economic Development Area of Xishan, Wuxi, Jiangsu Province, P.R.China. 214105 www.kipor.com Kipor reserves the right to modify any characteristic or specification without prior notice and without incurring any obligation. The illustrations may include optional equipment and/or accessories. All information in this brochure is based on the latest information available at the time of printing. Generators Generators Portable Series Generators Portable Series

Upload: others

Post on 12-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

T 86-510-85205041 F 86-510-85203796

www.kipor.com

No.1098,Dacheng Road, AnZhen, East Park, Economic Development Area of Xishan, Wuxi, Jiangsu Province, P.R.China. 214105

www.kipor.comKipor reserves the right to modify any characteristic or specification without prior notice

and without incurring any obligation. The illustrations may include optional equipment

and/or accessories. All information in this brochure is based on the latest information

available at the time of printing.

GeneratorsGeneratorsPortable SeriesGeneratorsPortable Series

Page 2: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

1 2Kipor Digital Generators deliver a stable, pure sine wave AC output, reliable enough to power even the most sensitive electronic equipment. When you need backup power at home, these technically advanced inverter generators will get you and all your appliances through any power related emergency. A high efficiency combustion system produces low emissions to maintain a clean environment. Kipor’ s unique Smart Throttle control system fosters exceptional fuel economy. Kipor Digital Generators deliver quiet, quality power in a compact package ranging in size from small easy to carry lightweight models to larger models with ergonomically designed handles and wheels that can be easily trans-ported.Sinemaster generators are designed for maximum portability.

KIPOR has the right generator to meet your portable power needs. KIPOR---the best choice in portable power. Outstanding serviceability and reliable performance in a simple, easy-to-use design make Kipor generators the best choice in portable power.

Ideal for RV, campground, home and outdoor power applications.

KIPOR Digital Sinemaster Generators provide clean and quiet portable power. These compact and light-weight generators are the perfect match for the RV or campground, when you want all the conveniences at home or bring a Digital generator to the worksite. The pure sine wave generators can run sensitive electronic equipment.

Sine wave diagram of KIPORDigital series generator

Startup Menu

2 5.00V/ 0.00e 5.00e/ Auto F 2 320V

GettingStarted

UsingQuick Help

AboutOscllloscope

LanguageChinese

Unique patented air cooling system

Inverter TechnologyClean high quality output can power the most sensitive electronic equipment.

Lightweight and compact design for maximum portability and efficiency.

Low noise design is optimized for effciency resulting in a clean digital generator.

Kipor Digital Generators feature low emissions and are highly fuel efficient and quiet making them among the most environmentally friendly generators on the market.

The microprocessor control instantly senses an overload or short circuit and immediately shuts off the engine to protect the generator and the load.

The inverter module adjusts the engine speed based on the load required resulting in reduced wear and fuel consumption.

Ideal for RV, campground and home applications.

Product Features3

DIGITAL GENERATORDIGITAL GENERATORPORTABLEPORTABLE

Page 3: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

IG gasoline modelsIG gasoline models

Product Features

IG

We wish to develop technologies to improveour lives.KIPOR is always on the move to achieve that dream.

GASOLINE

Low noise design

Lightweight and compact

Long running time

Advanced inverter technology provides reliable power for computers and other sensitive equipment

KIPOR has the right generator to meet your portable power needs. KIPOR---the best choice in portable power. Outstanding serviceability and reliable performance in a simple, easy-to-use design make Kipor generators the best choicein portable power.

Ideal for RV, Campground, Home Applica-tions and more.

KIPOR Digital Sinemaster Generators provide clean and quiet portable power. These compact and lightweight generators are the perfect match for the RV or campground when you want all the conveniences at home or bring a Digital generator to the worksite. The pure sinewave generators can run sensitive electronic equipments.

One of KIPOR’s never ending tasks is to produce high quality environmentally friendly generators. Today KIPOR offers digital generator which are considered advanced, reliable, and with a high quality output.

Dig

ital

Ge

nera

tor

Dig

ital

Ge

nera

tor

Lightweight PortableThe alternator is connected directly to the engine, eliminating the weight of the flywheel.

Unique Structure Utilizing The Latest TechnologyThe generator is cooled by a patented air intake system.The smart throttle power management system, the sound attenuated structure and inverter style output all combine to produce state of the art portable electric power.

CertificationKIPOR digital gensets have received EPA, CE, CARB, CETL and PSE certification.

Green Power System The KIPOR Digital Sinemaster Series is among the most environmental friendly class of generators in the marketplace.

Quality PowerKIPOR applies inverter technology to the Digital Sinemaster Series generators to produce pure sine wave AC output.

A Wide Range of Benefits In addition to clean, quiet, and efficient power, KIPOR offers superior overload and low oil level protection to all digital generators.

IG770IG770 IG1000IG1000 IG1000IG1000p

Rated output (kVA)Rated frequency (Hz)

Max. output (kVA)

Net weight (kg)

Dimensions(mm) Noise level (zero load-full load) [dB(A)/1m]

0.77415×220×360 460×250×395

0.750/60

60-6510.5

1.00.9

50/60

54-5914

IG1000sIG1000s

1.0600×250×400 460×250×395

0.950/60

54-5916

1.0(1.8 in parallel)0.9

50/60

54-5914

03 04

Page 4: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

IG gasoline modelsIG gasoline models

We wish to develop technologies to improveour lives.KIPOR is always on the move to achieve that dream.

Dig

ital

Ge

nera

tor

Dig

ital

Ge

nera

tor

IGGASOLINE

05 06

Product Features

IG2000IG2000 IG2000sIG2000s IG2000pIG2000p

Rated output (kVA)Rated frequency (Hz)

Max. output (kVA)

Net weight (kg)

2.0515×300×430 670×300×430 515×300×430

1.650/60

61-7322

2.6565×320×465 640×330×465

2.350/60

58-6529.5

2.01.6

50/60

61-7324.5

IG2600pIG2600pIG2600IG2600

Rated output (kVA)Rated frequency (Hz)

Max. output (kVA)

Net weight (kg)

Dimensions(mm) Noise level (zero load-full load) [dB(A)/1m]

2.0(3.6 in parallel)1.6

50/60

61-7322

2.6(4.68 in parallel)2.3(4.14 in parallel)

50/60

58-6529.5

Lightweight PortableThe alternator is connected directly to the engine, eliminating the weight of the flywheel.

Unique Structure Utilizing The Latest TechnologyThe generator is cooled by a patented air intake system.The smart throttle power management system, the sound attenuated structure and inverter style output all combine to produce state of the art portable electric power.

CertificationKIPOR digital gensets have received EPA, CE, CARB, CETL and PSE certification.

Green Power System The KIPOR Digital Sinemaster Series is among the most environmental friendly class of generators in the marketplace.

Quality PowerKIPOR applies inverter technology to the Digital Sinemaster Series generators to produce pure sine wave AC output.

A Wide Range of Benefits In addition to clean, quiet, and efficient power, KIPOR offers superior overload and low oil level protection to all digital generators.

Dimensions(mm)Noise level (zero load-full load) [dB(A)/1m]

Low noise design

Lightweight and compact

Long running time

Advanced inverter technology provides reliable power for computers and other sensitive equipment

Page 5: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

IG6000IG6000 IG6000hIG6000hIG3000EIG3000EIG3000pIG3000pIG3000IG3000

IG gasoline modelsIG gasoline models

Dig

ital

Ge

nera

tor

Dig

ital

Ge

nera

tor

IGGASOLINE

Rated output (kVA)Rated frequency (Hz)

Max. output (kVA)

Net weight (kg)

3.0685×430×495 685×430×495 495×410×430

2.850/60

63-7357

3.02.8

50/60

68-7840

6.0802×495×655

5.550/60

65-7596.5

6.01235×660×770

5.550/60

65-7598.3

3.0(5.4 in parallel)2.8

50/60

63-7357

Rated output (kVA)Rated frequency (Hz)

Max. output (kVA)

Net weight (kg)

Dimensions(mm) Noise level (zero load-full load) [dB(A)/1m]

Dimensions(mm)Noise level (zero load-full load) [dB(A)/1m]

We wish to develop technologies to improveour lives.KIPOR is always on the move to achieve that dream.

Product Features

07 08

New New

New

Low noise design

Lightweight and compact

Long running time

Advanced inverter technology provides reliable power for computers and other sensitive equipment

Lightweight PortableThe alternator is connected directly to the engine, eliminating the weight of the flywheel.

Unique Structure Utilizing The Latest TechnologyThe generator is cooled by a patented air intake system.The smart throttle power management system, the sound attenuated structure and inverter style output all combine to produce state of the art portable electric power.

CertificationKIPOR digital gensets have received EPA, CE, CARB, CETL and PSE certification.

Green Power System The KIPOR Digital Sinemaster Series is among the most environmental friendly class of generators in the marketplace.

Quality PowerKIPOR applies inverter technology to the Digital Sinemaster Series generators to produce pure sine wave AC output.

A Wide Range of Benefits In addition to clean, quiet, and efficient power, KIPOR offers superior overload and low oil level protection to all digital generators.

Page 6: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

09 10

Technical Data

Hz

kVA 0.9

1

6000

Without

KD09

1

Single phase

KG140

40×30

0.03768

8.5∶1

1.0/6000

Above SF SAE 10W-30

0.15

T.C.I

UR5

Recoil starter

-

Vehicle lead-free petrol

450

550

1.55

3

60-65

415×220×360

-

10.5

Portable, silent

KVA

V

A

r/min

COSΦ

mm

L

KW/(r/min)

g/KW.h

g/KW.h

L

h

L

IG770 IG1000Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Lube oil brand

Lube capacity

Ignition system

Spark plug

Starter system

Battery capacity

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

DC output

Generator type

Power factor

Phase number

Engine type

Structure type

Engine

Genset

Single cylinder, in-lined, 4-stroke,

air cooled,overhead valve

Single cylinder, in-lined, 4-stroke,

air cooled,overhead valve

Single cylinder, in-lined, 4-stroke,

air cooled,overhead valve

Single cylinder, in-lined, 4-stroke,

air cooled,overhead valve

Single cylinder, in-lined, 4-stroke,

air cooled,overhead camshaft

Fuel type

Lowest fuel consumption(g/KW.h)

Fuel consumptiom

kg

mm

dB(A)/1m

Overall dimension

Fuel tank capacity

Continuous running time(hr)(rated output)

Noise(unload-full load)

Net weight

Structure type

0.7

0.77

50 60 50 60

230

3.04

120/240

5.83/2.92

5500

12V-5.0A

KD10

1

Single phase

KG144

43.5×36

0.0535

8.5∶1

1.3/5500

Above SF SAE 10W-30、15W-40

0.2

T.C.I

UR5

Recoil starter

-

Vehicle lead-free petrol

420

550

2.6

3.8

54-59

460×250×395

-

14

Portable, silent

230

3.9

120/240

7.5/3.75

0.9

1(1.8KVA in parallel)

5500

12V-5.0A

KD10

1

Single phase

KG144

43.5×36

0.0535

8.5∶1

1.3/5500

Above SF SAE 10W-30、15W-40

0.2

T.C.I

UR5

Recoil starter

-

Vehicle lead-free petrol

420

550

2.6

3.8

54-59

600×250×400(after shrinkage)

330×215×140(lamp cap)

16

Portable, silent, lamp cap

IG1000s IG1000p

0.9

1

50 60 50 60

230

3.9

120/240

7.5/3.75

5500

12V-5.0A

KD10

1

Single phase

KG144

43.5×36

0.0535

8.5∶1

1.3/5500

Above SF SAE 10W-30、15W-40

0.2

T.C.I

UR5

Recoil starter

-

Vehicle lead-free petrol

420

550

2.6

3.8

54-59

460×250×395

-

14

Portable, silent

230

3.9

120/240

7.5/3.75

1.6

2

IG2000

50 60

4500

12V-5.0A

KD20

1

Single phase

KG158

58×40

0.1056

8.5∶1

2.2/4500

Above SF SAE 10W-30、15W-40

0.4

T.C.I

UR5

Recoil starter

-

Vehicle lead-free petrol

420

550

3.7

3

61-73

515×300×430

-

22

Portable, silent

230

7

120/240

13.3/6.7

Page 7: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

Technical Data

11 12

Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Lube oil brand

Lube capacity

Spark plug

Ignition system

Starter system

Battery capacity

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

DC output

Generator type

Power factor

Phase number

Engine type

Structure type

Engine

Genset

Fuel type

Lowest fuel consumption(g/KW.h)

Fuel consumptiom

Hz

kVA

KVA

V

A

r/min

COSΦ

mm

L

KW/(r/min)

g/KW.h

g/KW.h

L

h

L

kg

mm

dB(A)/1mNoise(unload-full load)

Overall dimension

Fuel tank capacity

Continuous running time(hr)(rated output)

Structure type

Net weight

2.3

2.6

IG2600h

50 60

3600

12V-5.0A

KD30

1

Single phase

KG166

66×50

0.171

8.5∶1

3.3/3600

Above SF SAE 10W-30、15W-40

0.55

T.C.I

WR7DC

Recoil starter

-

Vehicle lead-free petrol

395

500

5

3

58-65

640×330×465

-

31

Portable, silent, with stretch hand lever

230

10

120/240

19.2/9.6

2.3

2.6(4.68KVA in parallel)

IG2600p

50 60

3600

12V-5.0A

KD30

1

Single phase

KG166

66×50

0.171

8.5∶1

3.3/3600

Above SF SAE 10W-30、15W-40

0.55

T.C.I

WR7DC

Recoil starter

-

Vehicle lead-free petrol

395

500

5

3

58-65

640×330×465

-

29.5

Portable, silent, with stretch hand lever

230

10

120/240

19.2/9.6

4500

12V-5.0A

KD20

1

Single phase

KG158

58×40

0.1056

8.5∶1

2.2/4500

Above SF SAE 10W-30、15W-40

0.4

T.C.I

UR5

Recoil starter

-

Vehicle lead-free petrol

420

550

3.7

3

61-73

670×300×430

330×215×140(lamp cap)

24.5

Portable, silent, with light

IG2000s

1.6

2

50 60

230

7

120/240

13.3/6.7

Single cylinder, in-lined, 4-stroke,

air cooled,overhead camshaft

1.6

2(3.6KVA in parallel)

IG2000p

50 60

4500

12V-5.0A

KD20

1

Single phase

KG158

58×40

0.1056

8.5∶1

2.2/4500

Above SF SAE 10W-30、15W-40

0.4

T.C.I

UR5

Recoil starter

-

Vehicle lead-free petrol

420

550

3.7

3

61-73

515×300×430

-

22

Portable, silent

230

7

120/240

13.3/6.7

Single cylinder, in-lined, 4-stroke,

air cooled,overhead camshaft

Single cylinder, in-lined, 4-stroke,

air cooled,overhead camshaft

Single cylinder, in-lined, 4-stroke,

air cooled,overhead camshaft

3600

12V-5.0A

KD30

1

Single phase

KG166

66×50

0.171

8.5∶1

3.3/3600

Above SF SAE 10W-30、15W-40

0.55

T.C.I

WR7DC

Recoil starter

-

Vehicle lead-free petrol

395

500

5

3

58-65

565×320×465

-

29.5

Portable, silent

IG2600

2.3

2.6

50 60

230

10

120/240

19.2/9.6

Single cylinder, in-lined, 4-stroke,

air cooled,overhead camshaft

Page 8: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

Technical Data

13 14

Hz

kVA 2.8

3(5.4KVA in parallel)KVA

V

A

r/min

COSΦ

mm

L

KW/(r/min)

g/KW.h

g/KW.h

L

h

L

IG3000pGenerating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Lube oil brand

Lube capacity

Ignition system

Spark plug

Starter system

Battery capacity

Lowest fuel consumption(g/KW.h)

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

DC output

Generator type

Power factor

Phase number

Engine type

Structure type

Engine

Genset

Single-cylinder,4 stroke,air cooled,

cylinder inclined,overhead valve 

Single-cylinder,4 stroke,air cooled,

cylinder inclined,overhead valve 

Fuel type

kg

mm

dB(A)/1mNoise(unload-full load)

Overall dimension

Fuel tank capacity

Continuous running time(hr)(rated output)

Fuel consumptiom

Structure type

Net weight

50 60

3600

12V-5.0A

KD35

1

Single phase

KG205GETi

68×54

0.196

8.5∶1

4/3600

Above SF SAE 10W-30、15W-40

0.6

T.C.I

WR7DC

Recoil starterr,electric system

12V-8Ah

Vehicle lead-free petrol

395

500

13

6.7

63-73

685×430×495

-

57

Silent

230

12.2

120/240

23.3/11.7

2.8

3

IG3000E

50 60

3600

12V-5.0A

KD35

1

Single phase

KG205GEXi

68×54

0.196

8.5∶1

4/3600

Above SF SAE 10W-30、15W-40

0.6

T.C.I

WR7DC

Recoil starter,electric system

12V-8Ah

Vehicle lead-free petrol

395

500

9.4

5

68-78

495×410×430

-

40

Open-framed

230

12.2

120/240

23.3/11.7

Single-cylinder,4 stroke,air cooled,

cylinder inclined,overhead valve 

3600

12V-5.0A

KD70

1

Single phase

KG390GETi

88×64

0.389

8.5∶1

7.7/3600

Above SF SAE 10W-30、15W-40

1.1

T.C.I

WR7DC

Electric system

12V-11Ah

Vehicle lead-free petrol

374

500

22

6

65-75

802×495×655

-

96.5

Silent

IG6000

5.5

6

50 60

230

23.9

120/240

45.8/22.9

Single-cylinder,4 stroke,air cooled,

cylinder inclined,overhead valve 

5.5

6

IG6000h

50 60

3600

12V-5.0A

KD70

1

Single phase

KG390GETi

88×64

0.389

8.5∶1

7.7/3600

Above SF SAE 10W-30、15W-40

1.1

T.C.I

WR7DC

Electric system

12V-11Ah

Vehicle lead-free petrol

374

500

22

6

65-75

1235×660×770

-

98.3

Silent,with retractable handles

230

23.9

120/240

45.8/22.9

Single-cylinder,4 stroke,air cooled,

cylinder inclined,overhead valve 

4

4.3

IG4000

50 60

3600

12V-5.0A

KD40

1

Single phase

KG280GETi

78×58

0.277

8.5∶1

5.5/3600

Above SF SAE 10W-30、15W-40

1.1

T.C.I

WR7DC

Recoil starter,electric system

12V-11Ah

Vehicle lead-free petrol

374

500

13

5

65-73

805×470×570

-

75

Silent

230

17.4

120/240

33.3/16.7

3600

12V-5.0A

KD35

1

Single phase

KG205GETi

68×54

0.196

8.5∶1

4/3600

Above SF SAE 10W-30、15W-40

0.6

T.C.I

WR7DC

Recoil starter,electric system

12V-8Ah

Vehicle lead-free petrol

395

500

13

6.7

63-73

685×430×495

-

57

Silent

IG3000

Single-cylinder,4 stroke,air cooled,

cylinder inclined,overhead valve 

2.8

3

50 60

230

12.2

120/240

23.3/11.7

Page 9: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

2

Ready for big time power?

KIPOR ID series generators can handle those power draining startups demanded by some appliances and tools. KIPOR ID series generators feature low noise, are lightweight, and easy to use. They are an ideal outdoor power source whenever you need it. Its inverter produces a pure sine wave output which is perfect for any precision equipment.

DIESEL DIGITAL GENERATOR

Large current, compact size and light weight

4 Startup

The green line means traditional generatorThe red line means digital generator

Menu

2 5.00V/ 0.00e 5.00e/ Auto F 2 320V

1 KIPOR applies an “Intelligent Energy Saving Mode” which will adjust engine speed according to the load requirement. It will reduce fuel consumption by up to 25%.

Energy-saving 25% 3 Low noise design is optimized for effciency resulting in a clean digital generator.

Low noise design

High quality pure sine wave electrical outputIdeal for sensitive loads like computers, HD TV sets and microprocessor controlled appliances.

Pure sine wave output

Popular uses: Run an air conditioner, refrigerator, microwave oven or portable heater. On the job site, run a router, drill, sander, or air compressor.

DIGITAL GENERATORDIGITAL GENERATORPORTABLEPORTABLE

Page 10: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

ID diesel modelsID diesel models

IDDIESEL

Silent design 57-70db(a)/7m

Advanced inverter technology provides reliable power for computers and other sensitive equipment

Stylish and patented appearance design

Powered by a fuel efficient and long lasting diesel engine lowering the cost of operation

A permanent magnet alternator

eliminates excitation windings, carbon

brushes and rotor slip rings. The

construction is much simpler with the

stator bolted directly to the engine. The

alternator is smaller in size but can

achieve an alternator efficiency or 93%.

High in reliability, free of radio

interference, and capable of operating in

high humidity and dusty environments, a

KIPOR diesel inverter generator is your

best choice.

The KIPOR diesel inverter generator brings the latest technology to portable generators- the perfect match between the engine and a high efficiency multi-pole alternator and microprocessor controlled inverter system.

Dig

ital

Ge

nera

tor

Dig

ital

Ge

nera

tor

Product Features

Stable OutputApplication of inverter technology ensures a stable true sine-wave output with total harmonic distortion (THD) less than 1% and voltage and frequency fluctuation less than 1%.

Compact Structure, High OutputThe design is a compact structure resulting in a small size, light weight, quiet and high engine efficiency.

More EconomyEngine running speed varies with the load resulting in higher fuel economy and prolonged engine service life.Compared with Kipor conventional generators, Kipor diesel inverters reduce fuel consumption by up to 40%. Users benefit by a much lower cost of operation.

Optimized AlternatorA permanent magnet alternator eliminates excitation windings, carbon brushes and slip rings greatly reducing weight and service requirements.

Complete ProtectionLow oil pressure, high coolant temperature, over and under voltage, short circuit, and incorrect battery connection- these protections are integrated into each set and ensure long, safe, and reliable operation.

ID6000ID6000

5.5

875×530×750

550/60

62-69

Rated output (kVA)Rated frequency (Hz)

Max. output (kVA)

Overall dimension (LxWxH) (mm)

Noise level (7m)dB(A)Net weight (kg)

Rated output (kVA)Rated frequency (Hz)

Max. output (kVA)

Overall dimension (LxWxH) (mm)

Noise level (7m)dB(A)Net weight (kg)168

6

934×564×750

5.5

65-72189

ID7000ID700050/60

ID20ID20ID15ID15ID10ID10

10.566

9.550/60

285

1250×650×800

1668

14.5

500

2168

19.5

635

1500×780×1000

50/60 50/60

1600×780×1050

17 18

We wish to develop technologies to improve our lives.KIPOR is always on the move to achieve that dream.

New New

Page 11: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

Technical Data

19 20

Hz

kVA 5.5

6

1700-3300

KD70

Outer rotor multipole permanent magnet mortor/IGBT digital frequency switch

Single phase, 3 circuit

1

F

KD186FGETi

86×75

0.436

19.6∶1

6.3/3600

Pressure splashed

Above CD SAE 10W-30、15W-40

1.65

Electric system

12V-36Ah

281.5

14.5

6

62-69

875×530×750

168

Silent

KVA

V

A

r/min

COSΦ

mm

L

KW/(r/min)

L

h

g/KW.h

ID6000 ID7000Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Lubrication system

Lube oil brand

Lube capacity

Starter system

Battery capacity

Fuel consumptiom

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

Motor type/frequency type

Circuit mode

Power factor

Insulation grade

Generator type

Structure type

Engine type

Generator

Engine

Genset

Single-cylinder,4 stroke,air cooled,direct-injected

Single-cylinder,4 stroke,air cooled,direct-injected

Fuel type

Fuel tank capacity

Continuous running time(hr)(rated output)

kg

mm

dB(A)Noise level(7m)

Structure type

Overall dimension

Net weight

5

5.5

50 60 50 60

115/230

43.5/21.7

120/240

41.7/20.8

1700-3300

KD70

Single phase, 3 circuit

1

F

KD188FGETi

88×86

0.523

19∶1

7.0/3300

Pressure splashed

Above CD SAE 10W-30、15W-40

1.65

Electric system

12V-36Ah

279

395

14.5

5.5

65-72

934×564×750

189

Silent

115/230

47.8/23.9

120/240

45.8/22.9

Engine fuel consumption: 0#(summer)-10#(winter)-35#(cold)

Engine fuel consumption: 0#(summer)-10#(winter)-35#(cold)

Hz

kVA 14.5

16

1700-3000

KD100

Single phase, 3 circuit

1

H

KD373GTi

3-73×78

0.979

22.5∶1

13.3/3000

0.925

3.1

Pressure splashed

Above CD SAE 10W-30、15W-40

4.5

12V Electric system

12V 1.5KW

14V 20A

12V-45Ah

66

Silent

1250×650×800

285

KVA

V

A

r/min

COSΦ

mm

L

L

L

L

KW/(r/min)

V-KW

V-A

V-Ah

ID10 ID15Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Radiator tank

GeneratorWater-cooled water capacity

Lube capacity

Lubrication system

Lube oil brand

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

Generator type

Motor type/frequency type

Circuit mode

Power factor

Insulation grade

Engine type

Structure type

Engine

Genset

3-cylinder, in-lined, water-cooled,

4-stroke, turbocharged 

3-cylinder, in-lined, water-cooled,

4-stroke, direct-injected

4-cylinder, in-lined, water-cooled,

4-stroke,direct-injected 

Starter system

Starting motor capacity

Charging generator capacity

Battery capacity

Nosie level(7m)

kg

mm

dB(A)

Overall dimension

Fuel type

Structure type

Net weight

9.5

10.5

50 60 50 60

115/230

82.6/41.3

120/240

79.2/39.6

1500-2400

KD150

Single phase, 3 circuit

1

H

KKD388GTi

3-88×90

1.642

18.2∶1

19.6/2400

1.87

3.25

Pressure splashed

Above CD SAE 10W-30、15W-40

6.9

12V Electric system

12V 1.4KW

14V 20A

12V-65Ah

500

68

Silent

1500×780×1000

500

115/230

126/63

120/240

121/60.4

19.5

21

ID20

50 60

1500-2400

KD200

Single phase, 3 circuit

1

H

KD488GTi

4-88×90

2.19

18.2∶1

26.2/2400

2.29

3.7

Pressure splashed

Above CD SAE 10W-30、15W-40

8.5

12V Electric system

12V 1.4KW

14V 20A

12V-65Ah

68

Silent

1600×780×1050

635

115/230

169.6/84.8

120/240

162.5/81.3

Multipole Rb-Fe-B permanent magnet /IGBT digital frequency

Page 12: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

1 Features

CE certification

Strong powerAll generator sets are equipped with KIPOR four stroke diesel engines.

Low running noiseHigh efficiency combustion system ensures complete combustion. A large silencer dampens exhaust noise and engine sounds are contained by a double wall structure and liner absorber.

Digital Control PanelAll control functions of the generator are on a central panel. A digital display indicates the real time perfor-mance data of the generator such as voltage, frequency, oil pressure, and battery condition. The panel also displays any fault that shuts down the genset.

2 Benefits

Low oil alarm systemBefore the oil level drops to a dangerous level, the generator will stop automatically. It can only be restarted after the proper oil level is restored.

Application of new AVR The automatic voltage regulator (AVR) not only can smooth the output but also provide protection against overloads, avoiding expensive damage.

Advanced alternator windingWaveform distortion is kept at a minimum level with a stable output. The winding design protects the generator from short circuits and provides a stable output while running inductive loads.

3 ATS (Automatic Transfer Switch)

The new series of Kipor general purpose generator sets equipped with digital control panels can be equipped with an ATS. The ATS can automatically check and monitor genset running performance to ensure it is in good working condition. The ATS will also monitor utility power. In the event of a power failure or if utility power voltage and frequency is abnormal, the ATS will command the generator set to start automatically. Once utility power is restored, the ATS shift the load back to utility power and shuts down the generator.

Kipor always develops products from the customer’ s

point of view. To facilitate operation, Kipor equips its

generator with a user-friendly control panel as well as

provisions for a Kipor automatic transfer switch. The

new series of generator sets feature the following

benefits:

The new generation digital control panel has been

designed. The panel can be applied to dual voltage,

single phase and three phase generator sets.

When utility power fails, a Kipor automatic transfer switch

senses the loss of power and immediately starts the

generator. Once utility power is restored, the transfer

switch shifts your electric load back to utility power and

shuts down the generator.

The automatic transfer switch exercises the generator

weekly to ensure it is always in working order.

The automatic transfer switch can be mounted inside

the generator or attached as an optional accessory.

Most generators in this series are equipped with

brushless alternators which establish stable voltage in

a minimum amount of time. The generator set

maintains smooth and quality output.

Stylish and user friendly industry design.

GENERAL GEN SERIESPORTABLEPORTABLEGENERAL GEN SERIES

Page 13: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

23 24

KDE

KDE3500EKDE3500EKDE3500XKDE3500XKDE2200EKDE2200EKDE2200XKDE2200X

3.2/3.82.8/3.350/60

77

3.2/3.82.8/3.350/60

77

2.0/2.21.7/2.050/60

77

2.0/2.2640x480x530 640x480x530 655x480x530 655x480x530

1.7/2.050/60

77

Rated output (kVA)Rated frequency (Hz)

Max. output (kVA)

Noise level(7m) dB(A)Net weight (kg) 53 60 65 70

Dimensions(mm)

G E N E R A L

When the need arises for supplemental power, nothing takes the place of depend-ability. That’s why the KIPOR general series as the support of working professionals everywhere.

This diesel powered generator line is designed to accommodate the most common applications All offer great durability,

low vibration, quiet operation and recoil or electric starting.

An open frame configuration means it’s easy to handle and store when not in use.

Kipor develops its products from the point of view of the customer. They build in ease of operation and reliability into each generator they produce.

KDE diesel modelsKDE diesel models

Ge

nera

l Ge

nera

tor

We wish to develop technologies to prove achieve that dream klpor is always on the move

Product Features

Quieter and more powerful A high efficiency combustion system ensures complete combustion. A large silencer dampens exhaust noise and engine sounds are contained in a double-walled structure and absorbed by a special liner.Strong power with an easy start air cooled engine

Delivering the power you need Powerful, flexible, versatile, reliable, durable; KIPOR Generators have it covered on every level.

CE certification

Easily portableAn open frame configuration means it’s easy to handle and store when not in use.

Wide applicationVarious models are available to meet all customer requirements.

Versatile Power

Continuous operation without refueling

Convenient portability

Stable, clean power

Safe Shutdown

Recoil Starter / Electric Starter

Easy Maintenance, Long Lasting

Page 14: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

Rated output (kVA)Rated frequency (Hz)

Max. output (kVA)

Noise level(7m) dB(A)Net weight (kg)

KDE6500XKDE6500X

5.0/5.5720x492x655 720x492x655 920x560x645

4.5/5.050/60

7795

5.0/5.54.5/5.0

77100

KDE6500EKDE6500E50/60

KDE8000EAKDE8000EA50/60

6/7.155.5/6.5

82155

Rated output (kVA)Rated frequency (Hz)

Max. output (kVA)

Noise level(7m) dB(A)Net weight (kg)

KDE12EAKDE12EA

9.5/10930x620x6951030x600x650

8.5/950/60

85210

KDE12000EAKDE12000EA

9.5/10.58.5/9.550/60

83185

Dimensions(mm)

KDEG E N E R A L

When the need arises for supplemental power, nothing takes the place of dependability. That’s why the KIPOR general series as the support of working professionals everywhere.

This diesel powered generator line is designed to accommodate the most

common applications. All offer great durability, low vibration, quiet operation and recoil or electric starting.

An open frame configuration means it’s easy to handle and store when not in use.

Big power in an economical conventional diesel generator. Heavy, rugged construction lets you meet your electric needs even in a rough environment. In addition to a standard recoil starter, the KDE E- series also includes a convenient electric starter.

KDE diesel modelsKDE diesel models

Ge

nera

l Ge

nera

tor

25 26

Product Features

Quieter and more powerful A high efficiency combustion system ensures complete combustion. A large silencer dampens exhaust noise and engine sounds are contained in a double-walled structure and absorbed by a special liner.Strong power with an easy start air cooled engine

Delivering the power you need Powerful, flexible, versatile, reliable, durable; KIPOR Generators have it covered on every level.

CE certification

Control panelAll operating functions of the generator sets are on the panel. A digital readout displays operating parameters in real time such as output voltage and amperage. Circuit breakers protect the generator from overloads.

Easily portableAn open frame configuration means it’s easy to handle and store when not in use.

Wide applicationVarious models are available to meet all customer requirements.

New

Versatile Power

Continuous operation without refueling

Convenient portability

Stable, clean power

Safe Shutdown

Recoil Starter / Electric Starter

Easy Maintenance, Long Lasting

Dimensions(mm)

Page 15: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

Rated output (kVA)Rated frequency (Hz)

Max. output (kVA)

Noise level(7m) dB(A)Net weight (kg)

KDE6500X3KDE6500X3

6/75.5/6.350/60

7895

720x492x655 720x492x655 920x560x64578

KDE6500E3KDE6500E3

6/75.5/6.3

100

50/60

KDE8000EA3KDE8000EA350/60

7.2/8.256.5/7.5

82155

Dimensions(mm)

Rated output (kVA)Rated frequency (Hz)

Max. output (kVA)

Noise level(7m) dB(A)Net weight (kg)

KDE12EA3KDE12EA3

11/12.651030x600x650 930x620x695

10/11.550/60

85210

KDE12000EA3KDE12000EA3

11/12.6510/11.550/60

83185

Dimensions(mm)

KDEG E N E R A L

When the need arises for supplemental power, nothing takes the place of dependability. That’s why the KIPOR KDE series has the support of working professionals everywhere. This diesel powered generator line is produced in three versions to accommodate the most common applications. All offer great durability, low vibration levels, quiet operation, and recoil or convenient electric starting.

KDE diesel modelsKDE diesel models

Ge

nera

l Ge

nera

tor

Kipor’s general series generators are essential equipment for reliable power from the harshest building sites to emergency situations around the world.

27 28

Versatile Power

Continuous operation without refueling

Convenient portability

Stable, clean power

Safe Shutdown

Recoil Starter / Electric Starter

Easy Maintenance, Long Lasting

Product Features

Quieter and more powerful A high efficiency combustion system ensures complete combustion. A large silencer dampens exhaust noise and engine sounds are contained in a double-walled structure and absorbed by a special liner.Strong power with an easy start air cooled engine.

Delivering the power you need Powerful, flexible, versatile, reliable, durable; KIPOR Generators have it covered on every level.

CE certification

Control panelAll operating functions of the generator sets are on the panel. A digital readout displays operating parameters in real time such as output voltage and amperage. Circuit breakers protect the generator from overloads.

Easily portableAn open frame configuration means it’s easy to handle and store when not in use.

Wide applicationVarious models are available to meet all customer requirements.

Page 16: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

7 8

Product Features

KDE19EAKDE19EAKDE16EAKDE16EA KDE16EA3KDE16EA3 KDE19EA3KDE19EA3

Rated output (kVA)Rated frequency (Hz)

Max. output (kVA)

Noise level(7m) dB(A)Net weight (kg)

15.3/1813.9/16.4

50/60

90320

1210x650x765 1210x650x765 1210x650x765 1210x650x76590

13/1512/14

300

50/60 50/60

15/1713.5/15.5

90300

18.75/2116.25/1950/60

90320

Dimensions(mm)

KDEG E N E R A L

You need power to be clean, reliable, and efficient.You need plenty of capacity, advanced technology and exacting control.You need the KIPOR general KDE series.

Easy to maneuver with a wheel kit further improving transportability

Copper wound alternator for durability and voltage stability.

12V DC output charges batteries and allows use of low voltage lighting.

Grounding point on all units.

Automatic shutdown if the oil supply falls below a safe minimum level. A “NO START” feature will not allow a restart until the oil is replenished.

Multiple receptacles and voltage configura-tions are available to fit all market require-ments.

Circuit breakers protect against overload of the unit.

Ge

nera

l Ge

nera

tor

29 30

Kipor’s general series generators are essential equipment for reliable power from the harshest building sites to emergency situations around the world.

Versatile Power

Continuous operation without refueling

Convenient portability

Stable, clean power

Safe Shutdown

Recoil Starter / Electric Starter

Easy Maintenance, Long Lasting

Quieter and more powerful A high efficiency combustion system ensures complete combustion. A large silencer dampens exhaust noise and engine sounds are contained in a double-walled structure and absorbed by a special liner.Strong power with an easy start air cooled engine.

Delivering the power you need Powerful, flexible, versatile, reliable, durable; KIPOR Generators have it covered on every level.

CE certification

Control panelAll operating functions of the generator sets are on the panel. A digital readout displays operating parameters in real time such as output voltage and amperage. Circuit breakers protect the generator from overloads.

Easily portableAn open frame configuration means it’s easy to handle and store when not in use.

Wide applicationVarious models are available to meet all customer requirements.

Page 17: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

9

Product Features

Rated output (kVA)Rated frequency (Hz)

Max. output (kVA)

Noise level(7m) dB(A)Net weight (kg)

KDE6500TKDE6500T

5.0/5.54.5/5.050/60

72145

910x530x740

KDE7500TAKDE7500TA

5.7/6.25.2/5.650/60

73160

910x530x740

KDE3500TKDE3500T

835x530x74070

3.2/3.82.8/3.3

140

50/60

72

KDE6700TAKDE6700TA

930x530x7405.0/5.54.5/5.050/60

155

Dimensions(mm)

KDEG E N E R A L

Sure, the KIPOR KDE series will power heavy duty equipment but do you need lower noise as well?KDE-T models come with an enclosure to keep the noise down. A convenient electric starter gets the KDE series generators up and running quickly.

KDE diesel modelsKDE diesel models

Ge

nera

l Ge

nera

tor

31 32

Quieter and more powerful A high efficiency combustion system ensures complete combustion. A large silencer dampens exhaust noise and engine sounds are contained in a double-walled structure and absorbed by a special liner.Strong power with an easy start air cooled engine.

Delivering the power you need Powerful, flexible, versatile, reliable, durable; KIPOR Generators have it covered on every level.

CE certification

Control panelAll operating functions of the generator sets are on the panel. A digital readout displays operating parameters in real time such as output voltage and amperage. Circuit breakers protect the generator from overloads.

Easily portableAn open frame configuration means it’s easy to handle and store when not in use.

Wide applicationVarious models are available to meet all customer requirements.

Versatile Power

Continuous operation without refueling

Convenient portability

Stable, clean power

Safe Shutdown

Recoil Starter / Electric Starter

Easy Maintenance, Long Lasting

KDE6700TKDE6700T

930x530x740

50/60

5.0/5.54.5/5.0

72155

Easy to maneuver with a wheel kit further improving transportability .Copper wound alternator for durability and voltage stability.12V DC output allows battery charging and the use of low voltage lighting.Grounding point on all units.

Auto shutdown if oil level falls below minimum, “NO START” feature will not allow use if level is below minimum.A “NO START” feature will not allow a restart until the oil is replenished. Multiple receptacles and voltage configurations are available to fit all market requirements.Circuit breakers protect against overload of the unit.

KDE7500TKDE7500T50/60

KDE7500T3KDE7500T3

Rated output (kVA)Rated frequency (Hz)

Max. output (kVA)

Noise level(7m) dB(A)Net weight (kg)

Dimensions(mm)7.1/7.76.5/7.050/60

73160

910x530x7405.7/6.25.2/5.6

73160

910x530x740

Page 18: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

33 34

KDEG E N E R A L

Ge

nera

l Ge

nera

tor

Product Features

Stronger PowerKIPOR’s newly-developed single engine can be introduced with excellent low speed torque to the structure of gensets, not adding the overall dimension of the gensets; the application of KT5 and KT6 alternators enhances the generating efficiency.

Remarkable Noise ReductionThanks to persistent research and development of KIPOR’s technical departments gensets’ noise level at no load is decreased to only 65dB(A)/m, which has already been impressive progress for noise reduction.

More Convenient MaintenanceAVR, air filter and fuel filter are all designed with individual access panels, so that component replacement can be done without dismounting the genset cabinet.

Digital controllerKP310V1.0 digital controller can make RS232 serial communication with the master machine, realizing starting and stopping gensets and displaying real-time running data through the master machine.

With the purpose of expanding the generator group, KIPOR has brought out a new series of general generator sets on the basis of previous technical achievements. Compared with traditional models, diesel general gensets have been greatly improved by technical breakthrough and innovation, which are featured by impressive noise reduction, easy transportation, higher power, easy maintenance, and so on.

Rated output (kVA)Rated frequency (Hz)

Max. output (kVA)

Noise level(7m) dB(A)Net weight (kg)

KDE7000STAKDE7000STA

4.6/5.0870x645x710 870x645x710

4.2/4.650/60

72175

KDE7500STAKDE7500STA

5.5/6.05/5.5

73178

50/60

Dimensions(mm)

KDE diesel modelsKDE diesel models

Kipor’s general generators are essential equipment for reliable power,from the toughest building sites to emergency situation around the world.

Great optimization has been made in both engines and alternators of diesel general gensets, resulting in a large-scale power increase of the gensets.

KIPOR eliminates the application of general fixed castors, but utilizes universal ones in the new diesel gensets which are possible to revolve all around 360 degrees, which smooths the movement of the new gensets.

New New

New

Compact, Powerful and Long-Lasting

Convenient Use and Maintenance

All the Safety of KIPOR Products

Silent/super silent, low noise

Page 19: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

KDE12000TKDE12000TKDE12STAKDE12STA

Rated output (kVA)Rated frequency (Hz)

Max. output (kVA)

Noise level(7m) dB(A)Net weight (kg)

9.5/10.01350x650x760 1173x687x841

8.5/9.050/60

72310

9.5/10.58.5/9.5

72255

50/60

Dimensions(mm)

KDEG E N E R A L

KIPOR generators giving superior performance and maximum reliability. It gives great performance in acompact package.

KDE diesel modelsKDE diesel models

Ge

nera

l Ge

nera

tor

Extreme weather, construction, and manyother unforeseen complications can interruptthe electrical service upon which you and your family depend to continue your daily activities.

With a Kipor standby power system, life goes on even when the power goes out. When electricity is lost- day or night- you can be assured that you home will have all the comfort and convenience you are used to.

Compact, Powerful and Long-Lasting

Convenient Use and Maintenance

All the Safety of KIPOR Products

Silent/super silent, low noise

Kipor’s general series generators are essential equipment for reliable power from the harshest building sites to emergency situations around the world.

25 2635 36

Product Features

Cleaner, safer and quieterAll Kipor generators meet or exceed relevant standards for noise and emissions regulations

Robust and durableCompact, robust and resilient structures ensure long unit life and quiet operation. Thicker paint treatments resist the wear and tear caused by extreme environmental conditions

Designed to be easily transported A compact design makes it easy to fit into tight confines and still provide optimum performance

Easy to use The control panel is simple and easy to operateBuilt in monitoring of the unit’s performance provides a high level of information on the generator’s status

Designed for simple service-abilityLarge service doors provide easy access to preventive maintenance and service checks

Page 20: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

KDEG E N E R A L

Easy to maneuver with a wheel kit further improving transportability .

Copper wound alternator for durability and voltage stability.

12V DC output allows battery charging and the use of low voltage lighting.

Grounding point on all units.

Automatic shutdown if the oil supply falls below a safe minimum level. A “NO START” feature will not allow a restart until the oil is replenished.

Multiple receptacles and voltage configurations are available to fit all market requirements.

Circuit breakers protect against overload of the unit.

Sure, the Kipor KDE series will power heavy duty equipment but do you need lower noise as well?KDE-T models come with an enclosure to keep the noise down. A convenient electric starter gets the KDE series generators up and running quickly.

Rated output (kVA)Rated frequency (Hz)

Max. output (kVA)

Noise level(7m) dB(A)Net weight (kg)

KDE6700T3KDE6700T3

6/75.5/6.350/60

72155

930x535x742

KDE6500T3KDE6500T3

912x532x74072

6/75.5/6.3

148

50/60

930x535x742

KDE6700TA3KDE6700TA350/60

6/75.5/6.3

72155

Dimensions(mm)

KDE diesel modelsKDE diesel models

Ge

nera

l Ge

nera

tor

27 2837 38

Product Features

Quieter and more powerful A high efficiency combustion system ensures complete combustion. A large silencer dampens exhaust noise and engine sounds are contained in a double-walled structure and absorbed by a special liner.Strong power with an easy start air cooled engine.

Delivering the power you need Powerful, flexible, versatile, reliable, durable; KIPOR Generators have it covered on every level.

CE certification

Digital Control panelAll operating functions of the generator sets are on the panel. A digital readout displays operating parameters in real time such as output voltage and amperage. Circuit breakers protect the generator from overloads.

Easily portableAn open frame configuration means it’s easy to handle and store when not in use.

Wide applicationVarious models are available to meet all customer requirements.

Compact, Powerful and Long-Lasting

Convenient Use and Maintenance

All the Safety of KIPOR Products

Silent/super silent, low noise

KDE7500KDE7500TA3TA3

7.1/7.76.5/7.050/60

73160

910x530x740

KDE12STA3KDE12STA3

11/12.651350x650x760 1173x687x841

10/11.550/60

72310

KDE12000T3KDE12000T3

11/12.6510/11.550/60

73255

Rated output (kVA)Rated frequency (Hz)

Max. output (kVA)

Noise level(7m) dB(A)Net weight (kg)

Dimensions(mm)

Page 21: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

KDE19STAKDE19STAKDE16STAKDE16STA

KDEG E N E R A L

Your home and business needs power. Kipor generator sets are of professional quality and are designed for residential and office use. KIPOR generator sets are compact, sound insulated and reliable to provide clean and quiet backup power in case of a power outage. Your life continues as normal with complete peace of mind.

Rated output (kVA)Rated frequency (Hz)

Max. output (kVA)

Noise level(7m) dB(A)Net weight (kg)

13/151550x720x810 1550x720x810

12/1450/60

72420

15.3/1813.9/16.4

72442

50/60

Dimensions(mm)

KDE diesel modelsKDE diesel models

Ge

nera

l Ge

nera

tor

Kipor’s general generator series is essential equipment for reliable power from the toughest construction sites to emergency power situations around the world.

Extreme weather, construction, and other unforeseen complications can interrupt the electrical service upon which you and your family depend on for daily activities.

With a Kipor standby power system, life goes on when the power goes out. When electricity is lost, you can be assured that your home will have all the comfort and convenience to which you are accustomed.

29 3039 40

Compact, Powerful and Long-Lasting

Convenient Use and Maintenance

All the Safety of KIPOR Products

Silent/super silent, low noise

Product Features

Cleaner, safer and quieterAll Kipor generators meet or exceed relevant standards for noise and emissions regulations

Robust and durableCompact, robust and resilient structures ensure long unit life and quiet operation. Thicker paint treatments resist the wear and tear caused by extreme environmental conditions

Designed to be easily transported A compact design makes it easy to fit into tight confines and still provide optimum performance

Easy to use The control panel is simple and easy to operateBuilt in monitoring of the unit’s performance provides a high level of information on the generator’s status

Designed for simple service-abilityLarge service doors provide easy access to preventive maintenance and service checks

Page 22: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

41 42

KDE19STA3KDE19STA3KDE16STA3KDE16STA3 KDE40ST3KDE40ST3

KDEG E N E R A L

KIPOR not only makes reliable generator but we also understand how power affects your life. We know how unsettling it is to be without power. We understand how having the right power at the right time makes your home and attitude so much brighter. That’s why we design and develop unique differences into our backup power systems that you’ll appreciate when you need them the most.

Rated output (kVA)Rated frequency (Hz)

Max. output (kVA)

Noise level(7m) dB(A)Net weight (kg)

15/171550x720x810 1550x720x810 1900x950x1200

13.5/15.550/60

72420

18.75/2116.25/19

72442

50/60

4038

75985

50

Dimensions(mm)

KDE diesel modelsKDE diesel models

Ge

nera

l Ge

nera

tor

Extreme weather, construction, and other unforeseen complications can interrupt the electrical service upon which you and your family depend on for daily activities.

With a Kipor standby power system, life goes on when the power goes out. When electricity is lost, you can be assured that your home will have all the comfort and convenience to which you are accustomed.

Kipor’s general generators are essential equipment for reliable power,from the toughest building sites to emergency situation around the world.

Compact, Powerful and Long-Lasting

Convenient Use and Maintenance

All the Safety of KIPOR Products

Silent/super silent, low noise

Product Features

Cleaner, safer and quieterAll Kipor generators meet or exceed relevant standards for noise and emissions regulations

Robust and durableCompact, robust and resilient structures ensure long unit life and quiet operation. Thicker paint treatments resist the wear and tear caused by extreme environmental conditions

Designed to be easily transported A compact design makes it easy to fit into tight confines and still provide optimum performance

Easy to use The control panel is simple and easy to operateBuilt in monitoring of the unit’s performance provides a high level of information on the generator’s status

Designed for simple service-abilityLarge service doors provide easy access to preventive maintenance and service checks

Page 23: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

Rated output (kVA)Rated frequency (Hz)

Max. output (kVA)

Noise level(7m) dB(A)Net weight (kg)

KGE2500XKGE2500X

2.2/2.4590x430x430 675x520x540

2/2.250/60

6646

KGE4000XKGE4000X

3.3/4.03.0/3.5

6971

50/60

Dimensions(mm) Dimensions(mm)

Rated output (kVA)Rated frequency (Hz)

Max. output (kVA)

Noise level(7m) dB(A)Net weight (kg)

KGE6500XKGE6500X

5.5/6.5675x520x540 675x520x540 910x600x620 910x600x620

5.0/5.5

7483

50/60

KGE6500EKGE6500E

5.5/6.55.0/5.5

7490

50/60

KGEG E N E R A L

KIPOR KGE Series generators are some of the finest everyday working machines in the world. If you need a high value, rugged workhorse generator on the job, on the farm, or around the home site, Kipor has a KGE Series model perfect for your application.

KGE gasoline models KGE gasoline models

Ge

nera

l Ge

nera

tor

Versatile Power

Long Running Times

Easy to move around

Among the quietest in class

Safety Shutdowns

Recoil and Electric Starters

Easy Maintenance, Long Lasting

p y pp

43 44

Product Features

KGE12EAKGE12EAKGE12EKGE12E

9.5/10.58.5/9.550/60

77161

9.5/10.58.5/9.5

77161

50/60

Built to be economically used on the job site every day, the Kipor general gasoline series features an automatic voltage regulator (AVR) that delivers non-fluctuating power. It is of convention style construction with a strong durable frame. The electronic ignition makes for reliable starting in all conditions

Quieter and more powerful A high efficiency combustion system ensures complete combustion. A large muffler dampens exhaust noise and engine sounds are contained in a double-walled structure and absorbed by a special liner.Strong power with an easy start air cooled engine

Delivering the power you need Powerful, flexible, versatile, reliable, durable; KIPOR Generators have it covered on every level.

CE certification

Control panelThe generator is operated efficiently from a control panel designed with the user in mind. Circuit breakers protect the generator from overloads.

Easily portableAn open frame configuration means it’s easy to handle and store when not in use.

Wide applicationAvailable in a wide range of outputs to meet your specific requirements.

Page 24: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

1

KGEG E N E R A L

Built to be economically used on the job site every day, the Kipor general gasoline series features an automatic voltage regulator (AVR) that delivers non-fluctuating power. It is of convention style construction with a strong durable frame. The electronic ignition makes for reliable starting in all conditions.

A convenient electric starter gets the generator up and running quickly. Loaded with extras, the generator comes with a wrench set, battery, 12V DC charging cable, oil fill bottle, spare spark plug and spark plug wrench.

You need power to be clean,reliable and efficient. You need plenty of capacity, useful technology and exacting control. You need Kipor general KGE series.

Rated output (kVA)Rated frequency (Hz)

Max. output (kVA)

Noise level(7m) dB(A)Net weight (kg)

KGE6500X3KGE6500X3

6.0/7.0675x520x540 675x520x540 910x600x620 910x600x620

5.6/6.250/60

7483

KGE6500E3KGE6500E3

6.0/7.05.6/6.2

7490

50/60

KGE12E3KGE12E3

10.5/11.59.5/10.5

77167

50/60

KGE12EA3KGE12EA3

10.5/11.59.5/10.5

77167

50/60

45 46

KGE gasoline models KGE gasoline models

Ge

nera

l Ge

nera

tor

Kipor’s general generators are essential equipment for reliable power from the toughest construction sites to emergency situations around the world.

Product Features

Versatile Power

Long Running Times

Easy to move around

Among the quietest in class

Safety Shutdowns

Recoil and Electric Starters

Easy Maintenance, Long Lasting

Quieter and more powerful A high efficiency combustion system ensures complete combustion. A large muffler dampens exhaust noise and engine sounds are contained in a double-walled structure and absorbed by a special liner.Strong power with an easy start air cooled engine

Delivering the power you need Powerful, flexible, versatile, reliable, durable; KIPOR Generators have it covered on every level.

CE certification

Control panelThe generator is operated efficiently from a control panel designed with the user in mind. Circuit breakers protect the generator from overloads.

Easily portableAn open frame configuration means it’s easy to handle and store when not in use.

Wide applicationAvailable in a wide range of outputs to meet your specific requirements.

Dimensions(mm)

Page 25: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Lubrication system

Lube oil brand

Lube capacity

Starter system

Starting motor capacity

Charging generator capacity

Battery capacity

Fuel consumption ratio

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

Phase number

Generator type

Engine type

Structure type

Pole No.

Excitation mode

Power factor

Insulation grade

Generator

Engine

Genset

Fuel type

Nosie level(7m)

Fuel tank capacity

Overall dimension

Net weight

Panel type

Connection pole

DC12V output

Receptacle

Output

Hz

kVA

KW

kVA

KW

V

A

r/min

COSΦ

mm

KW

L

L

V-KW

V-A

V-Ah

g/KW.h Fuel consumption ratio g/KW.h

kg

mm

L

dB(A)

Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Lubrication system

Lube oil brand

Lube capacity

Starter system

Starting motor capacity

Charging generator capacity

Battery capacity

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

Phase number

Generator type

Engine type

Structure type

Pole No.

Excitation mode

Power factor

Insulation grade

Generator

Engine

Genset

Fuel type

Nosie level(7m)

Fuel tank capacity

Overall dimension

Net weight

Panel type

Connection pole

DC12V output

Receptacle

Output

Technical data

50 60

KDE2200X

50 60

KDE2200E

1.7

1.7

2

2

115/230

14.8/7.4

3000

2

2

2.2

2.2

120/240

16.7/8.3

3600

1.7

1.7

2

2

115/230

14.8/7.4

3000

2

2

2.2

2.2

120/240

16.7/8.3

3600

KT-2(160motor)

2

Single phase

1.0

B

KM170FG

70×55

0.211

20∶1

2.5 2.8

0.75

Recoil starter

Without

Without

Without

280.2 288.3

Common panel

Without

Connection pole output

77

13.5

640×480×530

53

KT-2(160motor)

2

1.0

B

KM170FG

70×55

0.211

20∶1

2.5 2.8

0.75

12V Electric system

12V 0.8KW

12V 3A

12V 36Ah

280.2 288.3

C

Common panel

2-Single phase

Without

Connection pole output

77

13.5

640×480×530

60

Above CD SAE 10W-30、15W-40

Self-excitation and constant voltage(with AVR)

Pressure splashed

Engine fuel consumption: 0#(summer)-10#(winter)-35#(cold)

Single cylinder, in-lined, 4-stroke,

air cooled, direct-injected

Single cylinder, in-lined, 4-stroke,

air cooled, direct-injected

2-Single phase

Hz

kVA

KW

kVA

KW

V

A

r/min

COSΦ

mm

KW

L

L

V-KW

V-A

V-Ah

kg

mm

L

dB(A)

60

Above CD SAE 10W-30、15W-40

Pressure splashed

Engine fuel consumption: 0#(summer)-10#(winter)-35#(cold)

47 48

50

KDE3500X

2.8

2.8

3.2

3.2

115/230

24.3/12.2

3000

3.3

3.3

3.8

3.8

120/240

27.5/13.8

3600

KT-3

2

Single phase

Self-excitation and constant voltage(with AVR)

1.0

B

KM178FG

78×62

0.296

20∶1

3.68 4

1.1

Recoil starter

Without

Without

Without

276.1 285.6

Common panel

2-Single phase

Without

77

13.5

655×480×530

65

single cylinder, in-lined, 4-stroke,

air cooled, direct-injected

60

3.3

3.3

3.8

3.8

120/240

27.5/13.8

3600

50

KDE3500E

2.8

2.8

3.2

3.2

115/230

24.3/12.2

3000

KT-3

2

Single phase

1.0

B

KM178FG

78×62

0.296

20∶1

3.68 4

1.1

12V Electric system

12V 0.8KW

12V 3A

12V 36Ah

276.1 285.6

Common panel

2-Single phase

Without

Connection pole output

77

13.5

655×480×530

70

single cylinder, in-lined, 4-stroke,

air cooled, direct-injected

Connection pole output

Page 26: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

Technical data

Hz

kVA

KW

kVA

KW

V

A

r/min

COSΦ

mm

KW

L

L

V-KW

V-A

V-Ah

g/KW.h

50 60

KDE6500E

4.5

4.5

5

5

115/230

39.1/19.6

3000

5

5

5.5

5.5

120/240

41.7/20.8

3600

KT5

2

Single phase

1.0

B

KM186FAG

86×72

0.418

19∶1

5.7 6.3

1.65

12V Electric system

12V 0.8KW

12V 3A

12V 36Ah

275.1 281.5

Common panel

2-Single phase

Without

Connection pole output

77

13.5

720×492×655

100

Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Lubrication system

Lube oil brand

Lube capacity

Starter system

Starting motor capacity

Charging generator capacity

Battery capacity

Fuel consumption ratio

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

Phase number

Generator type

Engine type

Structure type

Pole No.

Excitation mode

Power factor

Insulation grade

Generator

Engine

Genset

Above CD SAE 10W-30、15W-40

Self-excitation and constant voltage(with AVR)

Pressure splashed

Engine fuel consumption: 0#(summer)-10#(winter)-35#(cold)

Single cylinder, in-lined, 4-stroke,

air cooled, direct-injected

Single cylinder, in-lined, 4-stroke,

air cooled, direct-injected

Fuel type

kg

mm

L

dB(A)Nosie level(7m)

Fuel tank capacity

Overall dimension

Net weight

Panel type

Connection pole

DC12V output

Receptacle

Output

49 50

50 60

KDE6500X

4.5

4.5

5

5

115/230

39.1/19.6

3000

5

5

5.5

5.5

120/240

41.7/20.8

3600

KT5

2

Single phase

1.0

B

KM186FAG

86×72

0.418

19∶1

5.7 6.3

1.65

Recoil starter

Without

Without

Without

275.1 281.5

Common panel

2-Single phase

Without

Connection pole output

77

13.5

720×492×655

95

Hz

kVA

KW

kVA

KW

V

A

r/min

COSΦ

mm

L

L

KW

L

L

V-KW

V-A

V-Ah

50 60

KDE8000EA

50 60

KDE12EA

5.5

5.5

6

6

115/230

47.8/23.9

3000

6.5

6.5

7.15

7.15

120/240

54.2/27.1

3600

8.5

8.5

9.5

9.5

115/230

73.9/37

3000

9

9

10

10

120/240

75/37.5

3600

KT6.5

2

Single phase

1.0

B

KD2V78FG

78×64

0.61

20∶1

7.2 8

-

-

3.5

12V Electric system

12V 1.4KW

12V 3A

12V 36Ah

280.3 292.5

KI simple smart panel

2-Single phase

With

DC socket output

82

25

-

-

-

-

920x560x645 / 920x560x790(With caster)

155

KT12

2

Single phase

1.0

B

KM2V80G

80×79

0.794

23∶1

12.5 14.5

0.45

3.05

2.27

12V Electric system

12V 1.4KW

12V 20A

12V 45Ah

285 297

KI smart panel

2-Single phase

85

25

0.08

≤500

0.24

0.84

1030X600X650

210

Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Engine

Radiator tankWater-cooled water capacity

Lubrication system

Lube oil brand

Lube capacity

Starter system

Starting motor capacity

Charging generator capacity

Battery capacity

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

Phase number

Generator type

Engine type

Structure type

Pole No.

Excitation mode

Power factor

Insulation grade

Generator

Engine

Genset

Above CD SAE 10W-30、15W-40

Self-excitation and constant voltage(with AVR)

Pressure splashed

Engine fuel consumption: 0#(summer)-10#(winter)-35#(cold)

V type double cylinder, 4-stroke,

turbocharged,water-cooled

V type double cylinder, 4-stroke,

air cooled, direct-injected

Fuel type

kg

mm

With

-

L

dB(A)Nosie level(7m)

Fuel tank capacity

Air filter intake capacity

Exhaust temperature

Silencer exhaust capacity

Intake air flow

Overall dimension

Net weight

Panel type

Connection pole

DC 12V output

Receptacle

Output

m3/S

m3/S

m3/S

C。

g/KW.hFuel consumption ratio

Page 27: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

51 52

Technical data

Hz

kVA

KW

kVA

KW

V

A

r/min

COSΦ

mm

KW

L

L

V-KW

V-A

V-Ah

50 60

KDE6500X3

50 60

KDE8000EA3

5.5

4.4

6

4.8

400/230

7.9

3000

6.3

5

7

5.6

416/240

8.7

3600

6.5

5.2

7.2

5.7

400/230

9.4

3000

7.5

6

8.25

6.6

416/240

10.4

3600

KTS5

2

Three phase

0.8(lag)

B

KM186FAG

86×72

0.418

19∶1

5.7 6.3

1.65

Recoil starter

12 0.8KW

12 3A

12 36Ah

275.1 281.5

Common panel

78

13.5

720×492×655

95

KTS6

2

Three phase

0.8(lag)

B

KD2V78FG

78×64

0.61

20∶1

7.2 8

3.5

12V Electric system

12V 1.4KW

12V 3A

12V 36Ah

280.3 292.5

KI simple smart panel

82

25

920×560×645 / 920×560×790(With caster)

155

Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Lubrication system

Lube oil brand

Lube capacity

Starter system

Starting motor capacityV

Charging generator capacity

Battery capacity

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

Phase number

Generator type

Engine type

Structure type

Pole No.

Excitation mode

Power factor

Insulation grade

Generator

Engine

Genset

Above CD SAE 10W-30、15W-40

Self-excitation and constant voltage(with AVR)

Pressure splashed

Engine fuel consumption: 0#(summer)-10#(winter)-35#(cold)

Single cylinder, in-lined, 4-stroke,

air cooled, direct-injected

Fuel type

kg

mm

L

dB(A)Nosie level(7m)

Fuel tank capacity

Overall dimension

Net weight

Panel type

Connection pole

DC12V output

Receptacle

Output With

2-Single phase

Without

g/KW.hFuel consumption ratio

Hz

kVA

KW

kVA

KW

V

A

r/min

COSΦ

mm

KW

L

L

V-KW

V-A

V-Ah

50 60

KDE6500E3

5.5

4.4

6

4.8

400/230

7.9

3000

6.3

5

7

5.6

416/240

8.7

3600

KTS5

2

Three phase

0.8(lag)

B

KM186FAG

86×72

0.418

19∶1

5.7 6.3

1.65

12V Electric system

12 0.8KW

12 3A

12 36Ah

275.1 281.5

Common panel

78

13.5

720×492×655

100

Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Lubrication system

Lube oil brand

Lube capacity

Starter system

Starting motor capacity

Charging generator capacity

Battery capacity

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

Phase number

Generator type

Engine type

Structure type

Pole No.

Excitation mode

Power factor

Insulation grade

Generator

Engine

Genset

Above CD SAE 10W-30、15W-40

Self-excitation and constant voltage(with AVR)

Pressure splashed

Engine fuel consumption: 0#(summer)-10#(winter)-35#(cold)

Single cylinder, in-lined, 4-stroke,

air cooled, direct-injected

Fuel type

kg

mm

L

dB(A)Nosie level(7m)

Fuel tank capacity

Overall dimension

Net weight

Panel type

Connection pole

DC12V output

Receptacle

Output

50 60

KDE12000EA

8.5

8.5

9.5

9.5

115/230

73.9/37

3000

9.5

9.5

10.5

10.5

120/240

79.2/39.6

3600

KT12

2

Single phase

1.0

B

KD2V86FG

86×72

0.836

19∶1

11 12

4

12V Electric system

12V 1.4KW

12V 3A

12V 45Ah

273.5 285.7

KP310 smart panel

83

25

930×620×695 / 930x620x835(With caster)

185

With

2-Single phase

Without

Without

1-Single phase, 1-Three phase

Without

Without

1-Single phase, 1-Three phase

Without

V type double cylinder, 4-stroke,

air cooled, direct-injected

g/KW.hFuel consumption ratio

V type double cylinder, 4-stroke,

air cooled, direct-injected

Page 28: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

53 54

Technical data

3-cylinder, in-lined, water-cooled, 4-stroke, turbocharged

3-cylinder, in-lined, water-cooled,

4-stroke, turbocharged

Hz

kVA

KW

kVA

KW

V

A

r/min

COSΦ

mm

L

L

L

KW

L

V-KW

V-A

V-Ah

50 60

KDE12EA3

50 60

KDE12000EA3

10

8

11

8.8

400/230

14.4

3000

11.5

9.2

12.65

10.1

416/240

16

3600

10

8

11

8.8

400/230

14.4

3000

11.5

9.2

12.65

10.1

416/240

16

3600

KTS12

2

Three phase

0.8(lag)

B

KM2V80G

80×79

0.794

23∶1

12.5 14.5

0.45

3.05

2.27

12V Electric system

12V 1.4KW

12V 20A

12V 45Ah

285 297

KI smart panel

2-Single phase

85

25

0.08

≤500

0.24

0.84

1030X600X650

210

KTS12

2

Three phase

0.8(lag)

B

KD2V86FG

86×72

0.836

19∶1

11 12

-

-

4

12V Electric system

12V 1.4KW

12V 3A

12V 45Ah

273.5 285.7

KP310 smart panel

2-Single phase

83

25

-

-

-

-

930×620×695 / 930x620x835(With caster)

185

Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Engine

Radiator tankWater-cooled water capacity

Lubrication system

Lube oil brand

Lube capacity

Starter system

Starting motor capacity

Charging generator capacity

Battery capacity

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

Phase number

Generator type

Engine type

Structure type

Pole No.

Excitation mode

Power factor

Insulation grade

Generator

Engine

Genset

Above CD SAE 10W-30、15W-40

Self-excitation and constant voltage(with AVR)

Pressure splashed

Engine fuel consumption: 0#(summer)-10#(winter)-35#(cold)Fuel type

kg

mm

With

-

With

Without

L

dB(A)Nosie level(7m)

Fuel tank capacity

Air filter intake capacity

Exhaust temperature

Silencer exhaust capacity

Intake air flow

Overall dimension

Net weight

Panel type

Connection pole

DC 12V output

Receptacle

Output

m /S3

m /S3

m /S3

C。

V type double cylinder, 4-stroke,

air cooled, direct-injected

V type double cylinder, 4-stroke,

turbocharged,water-cooled

g/KW.hFuel consumption ratio

Hz

kVA

KW

kVA

KW

V

A

r/min

COSΦ

mm

L

L

L

KW

L

V-KW

V-A

V-Ah

50 60

KDE16EA

50 60

KDE19EA

12

10.8

13

11.7

115/230

104.4/52.2

3000

14

12.6

15

13.5

120/240

116.6/58.3

3600

13.9

12.5

15.3

13.8

115/230

121/60.4

3000

16.4

14.8

18

16.2

120/240

137/68.3

3600

KT14

2

Single phase

0.9(lag)

F

KM376AG

76×77

1.048

21.5∶1

15.3 17.5

1

5

4.8

12V Electric system

12V 1.4KW

14V 20A

12V 65Ah

280 295

KI smart panel

2-Single phase

90

38

0.12

≤520

0.27

1.28

1210×650×765

300

KT19

2

Single phase

0.9(lag)

F

KM376AG

76×77

1.048

21.5∶1

15.3 17.5

1

5

4.8

12V Electric system

12V 1.4KW

14V 20A

12V 65Ah

280 295

KI smart panel

2-Single phase

90

38

0.12

≤520

0.27

1.28

1210×650×765

320

Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Engine

Radiator tankWater-cooled water capacity

Lubrication system

Lube oil brand

Lube capacity

Starter system

Starting motor capacity

Charging generator capacity

Battery capacity

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

Phase number

Generator type

Engine type

Structure type

Pole No.

Excitation mode

Power factor

Insulation grade

Generator

Engine

Genset

Above CD SAE 10W-30、15W-40

Self-excitation and constant voltage(with AVR)

Pressure splashed

Engine fuel consumption: 0#(summer)-10#(winter)-35#(cold)Fuel type

kg

mm

With

-

With

-

L

dB(A)Nosie level(7m)

Fuel tank capacity

Air filter intake capacity

Exhaust temperature

Silencer exhaust capacity

Intake air flow

Overall dimension

Net weight

Panel type

Connection pole

DC 12V output

Receptacle

Output

m3/S

m3/S

m3/S

C。

g/KW.hFuel consumption ratio

Page 29: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

55 56

Technical data

Hz

kVA

KW

kVA

KW

V

A

r/min

COSΦ

mm

KW

L

L

V-KW

V-A

V-Ah

50 60

KDE3500T

50 60

KDE6500T

2.8

2.8

3.2

3.2

115/230

24.3/12.2

3000

3.3

3.3

3.8

3.8

120/240

27.5/13.8

3600

4.5

4.5

5

5

115/230

39.1/19.6

3000

5

5

5.5

5.5

120/240

41.7/20.8

3600

KT3(190motor)

2

Single phase

1.0

B

KM178FGET

78×62

0.296

20∶1

3.68 4

1.1

12V Electric system

12V 0.8KW

12V 3A

12V 36Ah

276.1 285.6

Common panel

2-Single phase

Without

Connection pole output

70

15

835×530×740

140

KT5

2

1.0

B

KM186FAGET

86×72

0.418

19∶1

5.7 6.3

1.65

12V Electric system

12V 0.8KW

12V 3A

12V 36Ah

275.1 281.5

Common panel

2-Single phase

Without

Connection pole output

72

15

910×530×740

145

Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Lubrication system

Lube oil brand

Lube capacity

Starter system

Starting motor capacity

Charging generator capacity

Battery capacity

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

Phase number

Generator type

Engine type

Structure type

Pole No.

Excitation mode

Power factor

Insulation grade

Generator

Engine

Genset

Above CD SAE 10W-30、15W-40

Self-excitation and constant voltage(with AVR)

Pressure splashed

Engine fuel consumption: 0#(summer)-10#(winter)-35#(cold)

Single cylinder, in-lined, 4-stroke,

air cooled, direct-injected

Single cylinder, in-lined, 4-stroke,

air cooled, direct-injected

Fuel type

kg

mm

L

dB(A)Nosie level(7m)

Fuel tank capacity

Overall dimension

Net weigh

Panel type

Connection pole

DC12V output

Receptacle

Output

g/KW.hFuel consumption ratio

3-cylinder, in-lined, water-cooled, 4-stroke, turbocharged

3-cylinder, in-lined, water-cooled, 4-stroke, turbocharged

Hz

kVA

KW

kVA

KW

V

A

r/min

COSΦ

mm

L

L

L

KW

L

V-KW

V-A

V-Ah

50 60

KDE16EA3

50 60

KDE19EA3

13.5

10.8

15

12

400/230

19.5

3000

15.5

12.4

17

13.6

416/240

21.5

3600

16.25

13

18.75

15

400/230

23.5

3000

19

15.2

21

16.8

416/240

26.4

3600

KTS16

2

Three phase

0.8(lag)

F

KM376AG

76×77

1.048

21.5∶1

15.3 17.5

1

5

4.8

12V Electric system

12V 1.4KW

14V 20A

12V 65Ah

280 295

KI smart panel

2-Single phase

90

38

0.12

≤520

0.27

1.28

1210×650×765

300

KTS19

2

Three phase

0.8(lag)

F

KM376AG

76×77

1.048

21.5∶1

15.3 17.5

1

5

4.8

12V Electric system

12V 1.4KW

14V 20A

12V65Ah

280 295

KI smart panel

2-Single phase

90

38

0.12

≤520

0.27

1.28

1210×650×765

320

Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Engine

Radiator tankWater-cooled water capacity

Lubrication system

Lube oil brand

Lube capacity

Starter system

Starting motor capacity

Charging generator capacity

Battery capacity

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

Phase number

Generator type

Engine type

Structure type

Pole No.

Excitation mode

Power factor

Insulation grade

Generator

Engine

Genset

Above CD SAE 10W-30、15W-40

Self-excitation and constant voltage(with AVR)

Pressure splashed

Engine fuel consumption: 0#(summer)-10#(winter)-35#(cold)Fuel type

kg

mm

With

-

With

-

L

dB(A)Nosie level(7m)

Fuel tank capacity

Air filter intake capacity

Exhaust temperature

Silencer exhaust capacity

Intake air flow

Overall dimension

Net weight

Panel type

Connection pole

DC 12V output

Receptacle

Output

m3/S

m3/S

m3/S

C。

g/KW.hFuel consumption ratio

Page 30: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

57 58

Technical data

50 60

KDE7000STAKDE7500T/TA

50 60

KDE7500STA

4.2

4.2

4.6

4.6

115/230

36.5/18.3

3000

4.6

4.6

5

5

120/240

38.3/19.2

3600

5

5

5.5

5.5

115/230

43.5/21.7

3000

5.5

5.5

6

6

120/240

45.8/22.9

3600

KT5

2

Single phase

1.0

B

KM186FAGET

86×72

0.418

19∶1

5.7 6.3

Pressure splashed

1.65

12V Electric system

12V 0.8KW

12V 3A

12V 36Ah

275.1 281.5

KP310 smart panel

2-Single phase

Without

72

15

870×645×710

175

KT6/W2

2

Single phase

1.0

B

KD188FAGET-1

88×86

0.532

19∶1

6.6 7.35

Pressure splashed

1.65

12V Electric system

12V 0.8KW

12V 3A

12V 36Ah

260 264.9

KP308 smart panel

2-Single phase

Without

73

15

870×645×710

178

Above CD SAE 10W-30、15W-40

Self-excitation and constant voltage(with AVR)

Engine fuel consumption: 0#(summer)-10#(winter)-35#(cold)

Single cylinder, in-lined, 4-stroke,

air cooled, direct-injected

Single cylinder, in-lined, 4-stroke,

air cooled, direct-injected

Hz

kVA

KW

kVA

KW

V

A

r/min

COSΦ

mm

KW

L

L

V-KW

V-A

V-Ah

50 60

KDE6700T

50 60

KDE6700TA

4.5

4.5

5

5

115/230

39.1/19.6

3000

5

5

5.5

5.5

120/240

41.7/20.8

3600

4.5

4.5

5

5

115/230

39.1/19.6

3000

5

5

5.5

5.5

120/240

41.7/20.8

3600

KT5

2

Single phase

1.0

B

KM186FAGET

86×72

0.418

19∶1

5.7 6.3

1.65

12V Electric system

12V 0.8KW

12V 3A

12V 36Ah

275.1 281.5

Common panel

2-Single phase

Without

Connection pole output

72

15

930×530×740

155

KT5

2

Single phase

1.0

B

KM186FAGET

86×72

0.418

19∶1

5.7 6.3

1.65

12V Electric system

12V 0.8KW

12V 3A

12V 36Ah

275.1 281.5

KI simple smart panel

72

15

930×530×740

155

Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Lubrication system

Lube oil brand

Lube capacity

Starter system

Starting motor capacity

Charging generator capacity

Battery capacity

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

Phase number

Generator type

Engine type

Structure type

Pole No.

Excitation mode

Power factor

Insulation grade

Generator

Engine

Genset

Above CD SAE 10W-30、15W-40

Self-excitation and constant voltage(with AVR)

Pressure splashed

Engine fuel consumption: 0#(summer)-10#(winter)-35#(cold)

Single cylinder, in-lined, 4-stroke,

air cooled, direct-injected

Single cylinder, in-lined, 4-stroke,

air cooled, direct-injected

Fuel type

kg

mm

Without

2-Single phase

DC socket output DC socket output

50 60

5.2

5.2

5.7

5.7

115/230

45.2/22.6

3000

5.6

5.6

6.2

6.2

120/240

46.7/23.3

3600

KT6/W2

2

Single phase

1.0

B

KD188FAGET-3

88×86

0.532

19∶1

6.6 7.35

Pressure splashed

1.65

12V Electric system

12V 0.8KW

12V 3A

12V 36Ah

260 264.9

Common panel / KP308 smart panel

2-Single phase

Without

Without

73

15

910×530×740

160

Single cylinder, in-lined, 4-stroke,

air cooled, direct-injected

DC socket output

L

dB(A)Nosie level(7m)

Fuel tank capacity

Overall dimension

Net weigh

Panel type

Connection pole

DC12V output

Receptacle

Output

g/KW.hFuel consumption ratio

Page 31: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

59 60

Technical data

V type double cylinder 4-stroke,

water-cooled, turbocharged

V type double cylinder 4-stroke,

air cooled, direct-injected

Hz

kVA

KW

kVA

KW

V

A

r/min

COSΦ

mm

L

L

L

KW

L

V-KW

V-A

V-Ah

50 60

KDE12STA

50 60

KDE12000T

8.5

8.5

9.5

9.5

115/230

73.9/37

3000

9

9

10

10

120/240

75/37.5

3600

8.5

8.5

9.5

9.5

115/230

73.9/37

3000

9.5

9.5

10.5

10.5

120/240

79.2/39.6

3600

KT12

2

Single phase

1.0

B

KM2V80G

80×79

0.794

23∶1

12.5 14.5

0.45

3.05

2.27

12V Electric system

12V 1.4KW

12V 20A

12V 36Ah

285 297

KI smart panel

2-Single phase

72

26

0.08

≤500

0.24

0.84

1350×650×760

310

KT12

2

Single phase

1.0

B

KD2V86FGET

86×72

0.836

19∶1

11 12

-

-

4

12V Electric system

12V 1.4KW

12V 3A

12V 45Ah

273.5 285.7

KP310 smart panel

3-Single phase

73

25

-

-

-

-

1173×687×841

255

Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Engine

Radiator tankWater-cooled water capacity

Lubrication system

Lube oil brand

Lube capacity

Starter system

Starting motor capacity

Charging generator capacity

Battery capacity

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

Phase number

Generator type

Engine type

Structure type

Pole No.

Excitation mode

Power factor

Insulation grade

Generator

Engine

Genset

Above CD SAE 10W-30、15W-40

Self-excitation and constant voltage(with AVR)

Pressure splashed

Engine fuel consumption: 0#(summer)-10#(winter)-35#(cold)Fuel type

kg

mm

With

-

With

Without

L

dB(A)Nosie level(7m)

Fuel tank capacity

Air filter intake capacity

Exhaust temperature

Silencer exhaust capacity

Intake air flow

Overall dimension

Net weight

Panel type

Connection pole

DC 12V output

Receptacle

Output

m3/S

m3/S

m3/S

C。

g/KW.hFuel consumption ratio

Hz

kVA

KW

kVA

KW

V

A

r/min

COSΦ

mm

L

L

L

KW

L

V-KW

V-A

V-Ah

60 50

Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Engine

Radiator tankWater-cooled water capacity

Lubrication system

Lube oil brand

Lube capacity

Starter system

Starting motor capacity

Charging generator capacity

Battery capacity

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

Phase number

Generator type

Engine type

Structure type

Pole No.

Excitation mode

Power factor

Insulation grade

Generator

Engine

Genset

Above CD SAE 10W-30、15W-40

Self-excitation and constant voltage(with AVR)

Pressure splashed

Engine fuel consumption: 0#(summer)-10#(winter)-35#(cold)Fuel type

kg

mm

L

dB(A)Nosie level(7m)

Fuel tank capacity

Air filter intake capacity

Exhaust temperature

Silencer exhaust capacity

Intake air flow

Overall dimension

Net weight

Panel type

Connection pole

DC 12V output

Receptacle

Output

m3/S

m3/S

m3/S

C。

g/KW.hFuel consumption ratio

50 60

KDE16STA

12

10.8

13

11.7

115/230

104.4/52.2

3000

14

12.6

15

13.5

120/240

116.6/58.3

3600

KT14

2

Single phase

0.9(lag)

F

KM376AG

76×77

1.048

21.5∶1

15.3 17.5

1

5

4.8

12V Electric system

12V 1.4KW

14V 20A

12V 65Ah

280 295

KI smart panel

2-Single phase

With

-

72

38

0.12

≤520

0.27

1.36

1550×720×810

420

3-cylinder, in-lined, water-cooled, 4-stroke, turbocharged

60

KDE19STA

13.9

12.5

15.3

13.8

115/230

121/60.4

3000

16.4

14.8

18

16.2

120/240

137/68.3

3600

KT19

2

Single phase

0.9(lag)

F

KM376AG

76×77

1.048

21.5∶1

15.3 17.5

1

5

4.8

12V Electric system

12V 1.4KW

14V 20A

12V 65Ah

280 295

KI smart panel

2-Single phase

With

-

72

38

0.12

≤520

0.27

1.36

1550×720×810

442

3-cylinder, in-lined, water-cooled, 4-stroke, turbocharged

Page 32: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

61 62

Technical data

Hz

kVA

KW

kVA

KW

V

A

r/min

COSΦ

mm

L

KW

L

V-KW

V-A

V-Ah

Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Lubrication system

Lube oil brand

Lube capacity

Starter system

Starting motor capacity

Charging generator capacity

Battery capacity

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

Phase number

Generator type

Engine type

Structure type

Pole No.

Excitation mode

Power factor

Insulation grade

Generator

Engine

Genset

Fuel type

kg

mm

60

7.0

5.6

7.7

6.2

416/240

9.7

3600

Without

L

dB(A)Nosie level(7m)

Fuel tank capacity

Overall dimension

Net weigh

Panel type

Connection pole

DC12V output

Receptacle

Output

g/KW.hFuel consumption ratio

Above CD SAE 10W-30、15W-40

Self-excitation and constant voltage(with AVR)

Engine fuel consumption: 0#(summer)-10#(winter)-35#(cold)

50 60

KDE7000STA3

5.25

4.2

5.75

4.6

400/230

7.6

3000

5.75

4.6

6.25

5

416/240

8

3600

KTS5

2

Three phase

0.8(lag)

B

KM186FAGET

86×72

0.418

19∶1

5.7 6.3

Pressure splashed

1.65

12V Electric system

12V 0.8KW

12V 3A

12V 36Ah

275.1 281.5

KP310 smart panel

1-Single phase,1-Three phase

Without

72

15

870×645×710

175

Single cylinder, in-lined, 4-stroke,

air cooled, direct-injected

Without

50 60

KDE6500T3

50 60

KDE6700T3

5.5

4.4

6

4.8

400/230

7.9

3000

6.3

5

7

5.6

416/240

8.7

3600

5.5

4.4

6

4.8

400/230

7.9

3000

6.3

5

7

5.6

416/240

8.7

3600

KTS5

2

Three phase

0.8(lag)

B

KM186FAGET

86×72

0.418

19∶1

5.7 6.3

1.65

12V Electric system

12V 0.8KW

12V 3A

12V 36Ah

275.1 281.5

Common panel

1-Single phase,1-Three phase

72

15

930×535×742

155

Single cylinder, in-lined, 4-stroke,

air cooled, direct-injected

KTS5

2

Three phase

0.8(lag)

B

KM186FAGET

86×72

0.418

19∶1

5.7 6.3

1.65

12V Electric system

12V 0.8KW

12V 3A

12V 36Ah

275.1 281.5

Common panel

1-Single phase,1-Three phase

72

15

912×532×740

148

Above CD SAE 10W-30、15W-40

Self-excitation and constant voltage(with AVR)

Pressure splashed

Engine fuel consumption: 0#(summer)-10#(winter)-35#(cold)

Without

Without

Without

Without

Single cylinder, in-lined, 4-stroke,

air cooled, direct-injected

50 60

KDE6700TA3

50

KDE7500T3/TA3

5.5

4.4

6

4.8

400/230

7.9

3000

6.3

5

7

5.6

416/240

8.7

3600

6.5

5.2

7.1

5.7

400/230

9.4

3000

KTS5

2

Three phase

0.8(lag)

B

KM186FAGET

86×72

0.418

19∶1

5.7 6.3

Pressure splashed

1.65

12V Electric system

12V 0.8KW

12V 3A

12V 36Ah

275.1 281.5

Common panel

Without

72

15

930×535×742

155

KTS6/W2

2

Three phase

0.8(lag)

B

KD188FAGET-3

88×86

0.532

19∶1

6.6 7.35

Pressure splashed

1.65

12V Electric system

12V 0.8KW

12V 3A

12V 36Ah

260 264.9

KP310 smart panel

1-Single phase,1-Three phase

Without

73

15

910×530×740

160

Single cylinder, in-lined, 4-stroke,

air cooled, direct-injected

Single cylinder, in-lined, 4-stroke,

air cooled, direct-injected

Without

1-Single phase,1-Three phase

Page 33: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

63 64

Technical data

Hz

kVA

KW

kVA

KW

V

A

r/min

COSΦ

mm

L

L

KW

L

L

V-KW

V-A

V-Ah

Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Engine

Radiator tankWater-cooled water capacity

Lubrication system

Lube oil brand

Lube capacity

Starter system

Starting motor capacity

Charging generator capacity

Battery capacity

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

Phase number

Generator type

Engine type

Structure type

Pole No.

Excitation mode

Power factor

Insulation grade

Generator

Engine

Genset

Above CD SAE 10W-30、15W-40

Self-excitation and constant voltage(with AVR)

Pressure splashed

Engine fuel consumption: 0#(summer)-10#(winter)-35#(cold)Fuel type

kg

mm

L

dB(A)Nosie level(7m)

Fuel tank capacity

Air filter intake capacity

Exhaust temperature

Silencer exhaust capacity

Intake air flow

Overall dimension

Net weight

Panel type

Connection pole

DC 12V output

Receptacle

Output

m3/S

m3/S

m3/S

C。

g/KW.hFuel consumption ratio

Hz

kVA

KW

kVA

KW

V

A

r/min

COSΦ

mm

L

L

L

KW

L

V-KW

V-A

V-Ah

Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Engine

Radiator tankWater-cooled water capacity

Lubrication system

Lube oil brand

Lube capacity

Starter system

Starting motor capacity

Charging generator capacity

Battery capacity

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

Phase number

Generator type

Engine type

Structure type

Pole No.

Excitation mode

Power factor

Insulation grade

Generator

Engine

Genset

Above CD SAE 10W-30、15W-40

Self-excitation and constant voltage(with AVR)

Pressure splashed

Engine fuel consumption: 0#(summer)-10#(winter)-35#(cold)Fuel type

kg

mm

L

dB(A)Nosie level(7m)

Fuel tank capacity

Air filter intake capacity

Exhaust temperature

Silencer exhaust capacity

Intake air flow

Overall dimension

Net weight

Panel type

Connection pole

DC 12V output

Receptacle

Output

m3/S

m3/S

m3/S

C。

g/KW.hFuel consumption ratio

50 60

KDE7500STA3

6.25

5

6.9

5.5

400/230

9

3000

6.9

5.5

7.5

6

416/240

9.6

3600

KTS6

2

Three phase

0.8(lag)

B

KD188FGET-1

88×86

0.532

19∶1

6.6 7.35

-

-

1.65

12V Electric system

12V 0.8KW

12V 3A

12V 36Ah

275.1 281.5

KP310 smart panel

1-Single phase,1-Three phase

Without

73

15

-

-

-

-

870×645×710

178

Single cylinder, in-lined, 4-stroke,

air cooled, direct-injected

Without

50 60

KDE12000T3

10

8

11

8.8

400/230

14.4

3000

11.5

9.2

12.65

10.1

416/240

16

3600

KTS12

2

Three phase

0.8(lag)

B

KD2V86FGET

86×72

0.836

19∶1

11 12

-

-

4

12V Electric system

12V 1.4KW

12V 3A

12V 45Ah

273.5 285.7

KP310 smart panel

2-Single phase,1-Three phase

With

Without

73

25

-

-

-

-

1173×687×841

255

V type double cylinder 4-stroke,

air cooled, direct-injected

V type double cylinder 4-stroke,

water-cooled, turbocharged

50 60

KDE12STA3

10

8

11

8.8

400/230

14.4

3000

11.5

9.2

12.65

10.1

416/240

16

3600

KTS12

2

Three phase

0.8(lag)

B

KM2V80G

80×79

0.794

23∶1

12.5 14.5

0.45

3.05

2.27

12V Electric system

12V 1.4KW

12V 20A

12V 36Ah

285 297

KI smart panel

2-Single phase

72

26

0.08

≤500

0.24

0.84

1350×650×760

310

With

-

50 60

KDE16STA3

13.5

10.8

15

12

400/230

19.5

3000

15.5

12.6

17

13.6

416/240

21.5

3600

KTS16

2

Three phase

0.8(lag)

F

KM376AG

76×77

1.048

21.5∶1

15.3 17.5

1

5

4.8

12V Electric system

12V 1.4KW

14V 20A

12V 65Ah

280 295

KI smart panel

2-Single phase

With

-

72

38

0.12

≤520

0.27

1.36

1550×720×810

420

3-cylinder, in-lined, water-cooled, 4-stroke, turbocharged

Page 34: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

65 66

Technical data

Hz

kVA

KW

kVA

KW

V

A

r/min

COSΦ

mm

L

L

L

KW

L

V-KW

V-A

V-Ah

60

Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Engine

Radiator tankWater-cooled water capacity

Lubrication system

Lube oil brand

Lube capacity

Starter system

Starting motor capacity

Charging generator capacity

Battery capacity

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

Phase number

Generator type

Engine type

Structure type

Pole No.

Excitation mode

Power factor

Insulation grade

Generator

Engine

Genset

Above CD SAE 10W-30、15W-40

Self-excitation and constant voltage(with AVR)

Engine fuel consumption: 0#(summer)-10#(winter)-35#(cold)Fuel type

kg

mm

L

dB(A)Nosie level(7m)

Fuel tank capacity

Air filter intake capacity

Exhaust temperature

Silencer exhaust capacity

Intake air flow

Overall dimension

Net weight

Panel type

Connection pole

DC 12V output

Receptacle

Output

m3/S

m3/S

m3/S

C。

g/KW.hFuel consumption ratio

4-cylinder, in-lined, water-cooled, 4-stoke,direct-injected

50

KDE19STA3

16.25

13

18.75

15

400/230

23.5

3000

19

15.2

21

16.8

416/240

26.4

3600

KTS19

2

Three phase

0.8(lag)

F

KM376AG

76×77

1.048

21.5∶1

15.3 17.5

1

5

4.8

12V Electric system

12V 1.4KW

14V 20A

12V 65Ah

280 295

KI smart panel

2-Single phase

72

38

0.12

≤520

0.27

1.36

1550×720×810

442

Pressure splashed

With

-

3-cylinder, in-lined, water-cooled, 4-stroke, turbocharged

50

KDE40ST3

38

30.4

40

32

400/230

54.8

3000

KFS38-2P

2

-

0.8(lag)

H

KM493G-1

93×102

2.771

18.2:1

40

3.9

8

Pressure splashed

8.5

12V Electric system

12V 2.8KW

14V 20A

12V 80Ah

272

KI smart pane

2-Single phase

With

-

68

95

0.1

≤550

0.14

2.27

1900×950×1200

985

Hz

kVA

KW

kVA

KW

V

A

r/min

COSΦ

mm

KW

L

L

V-KW

V-A

V-Ah

50 60

KGE2500X

50 60

KGE4000X

2

2

2.2

2.2

115/230

17.4/8.7

3000

2.2

2.2

2.4

2.4

120/240

18.3/9.2

3600

3

3

3.3

3.3

115/230

26/13

3000

3.5

3.5

4

4

120/240

29.2/14.6

3600

KT-2.5(160motor)

2

Single phase

1.0

B

KG200G(1)X(high cover)

68×54

0.196

8.5∶1

3.6 4

Indu vtive(TCI)

Splashed

0.6

Recoil starter

-

-

-

395

Vehicle lead-free petrol

Common panel

2-Single phase

Without

Connection pole output

66

13.5

590×430×430

46

KT-3(190motor)

2

Single phase

1.0

B

KG280G(1)(high cover)

78×58

0.277

8.5∶1

5 5.5

Indu vtive(TCI)

Splashed

1.1

Recoil starter

-

-

-

374

Vehicle lead-free petrol

Common panel

3-Single phase

Without

Connection pole output

69

25

675×520×540

71

Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Inigation system

Lubrication system

Lube oil brand

Lube capacity

Starter system

Starting motor capacity

Charging generator capacity

Battery capacity

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

Phase number

Generator type

Engine type

Structure type

Pole No.

Excitation mode

Power factor

Insulation grade

Generator

Engine

Genset

Above SF SAE 10W-30、15W-40

Self-excitation and constant voltage(with AVR)

Single cylinder, 4-stroke,air cooled,

cylinder inclined,overhead valve

Single cylinder, 4-stroke,air cooled,

cylinder inclined,overhead valve

Fuel type

kg

mm

L

dB(A)Nosie level(7m)

Fuel tank capacity

Overall dimension

Net weigh

Panel type

Connection pole

DC12V output

Receptacle

Output

g/KW.hFuel consumption ratio

Page 35: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

67 68

Technical data

50 60

KGE12EA

8.5

8.5

9.5

9.5

115/230

73.9/36.9

3000

9.5

9.5

10.5

10.5

120/240

79.2/39.6

3600

KT12

2

Single phase

1.0

B

KG690G

78×72

0.688

8.5∶1

12 14

Indu vtive(TCI)

Pressure splashed

1.3

12V Electric system

12V 1.4KW

12V 8A

12V 36Ah

370

Vehicle lead-free petrol

KI simple smart panel

2-Single phase

With

Without

77

25

910×600×620

161

Above SF SAE 10W-30、15W-40

Self-excitation and constant voltage(with AVR)

50 60

KGE12E

8.5

8.5

9.5

9.5

115/230

73.9/36.9

3000

9.5

9.5

10.5

10.5

120/240

79.2/39.6

3600

KT12

2

Single phase

1.0

B

KG690G

78×72

0.688

8.5∶1

12 14

Indu vtive(TCI)

Pressure splashed

1.3

12V Electric system

12V 1.4KW

12V 8A

12V 36Ah

370

Vehicle lead-free petrol

Common panel

3-Single phase

With

Without

77

25

910×600×620

161

V type double cylinder, 4-stroke,

air cooled, overhead camshaft

V type double cylinder, 4-stroke,

air cooled, overhead camshaft

50 60

KGE6500X

50 60

KGE6500E

5

5

5.5

5.5

115/230

43.5/21.7

3000

5.5

5.5

6.5

6.5

120/240

45.8/22.9

3600

5

5

5.5

5.5

115/230

43.5/21.7

3000

5.5

5.5

6.5

6.5

120/240

45.8/22.9

3600

KT6

2

Single phase

1.0

B

KG390GX

88×64

0.389

8.5∶1

7 7.7

Indu vtive(TCI)

Splashed

1.1

Recoil starter

-

-

-

374

Vehicle lead-free petrol

Common panel

3-Single phase

Without

Without

74

25

675×520×540

83

KT6

2

Single phase

1.0

B

KG390GEX

88×64

0.389

8.5∶1

7 7.7

Indu vtive(TCI)

Splashed

1.1

12V Electric system / recoil starter

12V 0.4KW

12V 8A

12V 11Ah

374

Vehicle lead-free petrol

Common panel

3-Single phase

Without

Connection pole output

74

25

675×520×540

90

Above SF SAE 10W-30、15W-40

Self-excitation and constant voltage(with AVR)

Single cylinder, 4-stroke,air cold,

cylinder inclined,overhead valve

Single cylinder, 4-stroke,air cold,

cylinder inclined,overhead valve

Hz

kVA

KW

kVA

KW

V

A

r/min

COSΦ

mm

KW

L

L

V-KW

V-A

V-Ah

Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Inigation system

Lubrication system

Lube oil brand

Lube capacity

Starter system

Starting motor capacity

Charging generator capacity

Battery capacity

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

Phase number

Generator type

Engine type

Structure type

Pole No.

Excitation mode

Power factor

Insulation grade

Generator

Engine

Genset

Fuel type

kg

mm

L

dB(A)Nosie level(7m)

Fuel tank capacity

Overall dimension

Net weigh

Panel type

Connection pole

DC12V output

Receptacle

Output

g/KW.hFuel consumption ratio

Hz

kVA

KW

kVA

KW

V

A

r/min

COSΦ

mm

KW

L

L

V-KW

V-A

V-Ah

Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Inigation system

Lubrication system

Lube oil brand

Lube capacity

Starter system

Starting motor capacity

Charging generator capacity

Battery capacity

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

Phase number

Generator type

Engine type

Structure type

Pole No.

Excitation mode

Power factor

Insulation grade

Generator

Engine

Genset

Fuel type

kg

mm

L

dB(A)Nosie level(7m)

Fuel tank capacity

Overall dimension

Net weigh

Panel type

Connection pole

DC12V output

Receptacle

Output

g/KW.hFuel consumption ratio

Page 36: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

69 70

Technical data

50 60

KGE12EA3

9.5

7.6

10.5

8.4

400/230

13.7

3000

10.5

8.4

11.5

9.2

416/240

14.6

3600

KTS12

2

Three phase

0.8(lag)

B

KG690G

78×72

0.688

8.5∶1

12 14

Indu vtive(TCI)

Pressure splashed

1.3

12V Electric system

12V 1.4KW

12V 8A

12V 36Ah

370

Vehicle lead-free petrol

KI simple smart panel

2-Single phase

With

Without

77

25

910×600×620

167

Above SF SAE 10W-30、15W-40

50 60

KGE12E3

9.5

7.6

10.5

8.4

400/230

13.7

3000

10.5

8.4

11.5

9.2

416/240

14.6

3600

KTS12

2

Three phase

0.8(lag)

B

KG690G

78×72

0.688

8.5∶1

12 14

Indu vtive(TCI)

Pressure splashed

1.3

12V Electric system

12V 1.4KW

12V 8A

12V 36Ah

370

Vehicle lead-free petrol

Common panel

2-Single phase,1-Three phase

With

Without

77

25

910×600×620

167

Hz

kVA

KW

kVA

KW

V

A

r/min

COSΦ

mm

KW

L

L

V-KW

V-A

V-Ah

50 60

KGE6500X3

50 60

KGE6500E3

5.6

4.5

6

4.8

400/230

8

3000

6.2

5

7

5.6

416/240

8.6

3600

5.6

4.5

6

4.8

400/230

8

3000

6.2

5

7

5.6

416/240

8.6

3600

KTS6

2

Three phase

0.8(lag)

B

KG390GX

88×64

0.389

8.5∶1

7 7.7

Indu vtive(TCI)

Splashed

1.1

Recoil starter

-

-

-

374

Vehicle lead-free petrol

Common panel

2-Single phase,1-Three phase

Without

Connection pole output

74

25

675×520×540

83

KTS6

2

Three phase

0.8(lag)

B

KG390GEX

88×64

0.389

8.5∶1

7 7.7

Indu vtive(TCI)

Splashed

1.1

12V Electric system or recoil starter

12V 0.4KW

12V 8A

12V 11Ah

374

Vehicle lead-free petrol

Common panel

2-Single phase,1-Three phase

Without

Connection pole output

74

25

675×520×540

90

Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Inigation system

Lubrication system

Lube oil brand

Lube capacity

Starter system

Starting motor capacity

Charging generator capacity

Battery capacity

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

Phase number

Generator type

Engine type

Structure type

Pole No.

Excitation mode

Power factor

Insulation grade

Generator

Engine

Genset

Above SF SAE 10W-30、15W-40

Self-excitation and constant voltage(with AVR)

Single cylinder, 4-stroke,air cooled,

cylinder inclined,overhead valve

Single cylinder, 4-stroke,air cooled,

cylinder inclined,overhead valve

Fuel type

kg

mm

L

dB(A)Nosie level(7m)

Fuel tank capacity

Overall dimension

Net weigh

Panel type

Connection pole

DC12V output

Receptacle

Output

g/KW.hFuel consumption ratio

Hz

kVA

KW

kVA

KW

V

A

r/min

COSΦ

mm

KW

L

L

V-KW

V-A

V-Ah

Generating set

Rated frequency

Bore×stroke

Displacement

Compression ratio

Rated power

Inigation system

Lubrication system

Lube oil brand

Lube capacity

Starter system

Starting motor capacity

Charging generator capacity

Battery capacity

Prime power

Standby power

Rated voltage

Rated current

Rated rotation speed

Phase number

Generator type

Engine type

Structure type

Pole No.

Excitation mode

Power factor

Insulation grade

Generator

Engine

Genset

Fuel type

kg

mm

L

dB(A)Nosie level(7m)

Fuel tank capacity

Overall dimension

Net weigh

Panel type

Connection pole

DC12V output

Receptacle

Output

g/KW.hFuel consumption ratio

V type double cylinder, 4-stroke,

air cooled, overhead camshaft

V type double cylinder, 4-stroke,

air cooled, overhead camshaft

Self-excitation and constant voltage(with AVR)

Page 37: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

2

Kipor Portable welding generator series is a dual use unit featuring welding and power generation. Power ranges from 2 to 10 kVA. Welding current ranges from 160 to 450A. This generator set is developed upon Kipor’ s latest techno-logy built upon Kipor’ s 10 year history of manufacturing welder/generators.

The power supply for welding is self-driven. It can be used in a host of applications- railroading, highway construction, port operations, oil fields, chemical plants, building construction, agriculture and many more. Self- excitation and constant voltage enhance the generator performance. The lightweight and compact design facili-tates on-site maneuverability and saves storage space.

Simultaneous use

Generating and welding can be performed simultaneously. The welding operation won’ t impact the waveform and voltage of the generator.

1 KIPOR original technology has been utilized to develop and advanced product with dual functions- welding and power generation.

One unit, dual function

4 Excellent electricity

A new AVR (automatic voltage regula-tor) and damper winding further enhances the electricity production with extremely low voltage fluctuation and minimum waveform distortion.

The unit can achieve a perfect wave-form of the welding voltage by utilizing IGBT and PWM technology. The non-fluctuating welding current produces a high quality welding operation.

A lightweight and compact design improves on-site maneuverability and saves storage space. It has four durable casters to facilitate movement.

3 Perfect welding

6 Wide application

The welding arc is super smooth to get perfect quality welds. The welding current regulation is broad to accommodate a variety of welding rods.

5 Easy maneuver ability

WELDING GEN SERIESPORTABLEPORTABLEWELDING GEN SERIES

Page 38: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

KDE180TWKDE180TWKDE180EWKDE180EWKDE180XWKDE180XWKDE5000EWKDE5000EWKDE5000XWKDE5000XW

KDE diesel modelsKDE diesel models

KDEDIESEL

One unit, dual function

Simultaneous use

Perfect welding

Excellent electricity

Easy maneuverability

We

ldin

g G

ene

rato

rW

eld

ing

Ge

nera

tor

Product Features

One Unit, Dual FunctionKIPOR original technology has been utilized to develop and advanced product with dual functions- welding and power generation

Simultaneous UseGenerating and welding can be operated simultaneously, while welding operation won’t impact an influence on the waveform and voltage of the generating operation.

Perfect WeldingThe unit can achieve a perfect waveform of the welding voltage by utilizing IGBT and PWM technology. The non-fluctuating welding current produces a high quality welding operation.

High Quality PowerNew A new AVR (automatic voltage regulator) and damper winding further enhances the electricity production with extremely low voltage fluctuation and minimum waveform distortion.

Easy ManeuverabilityA lightweight and compact design improves on-site maneuverability and saves storage space. It has four durable casters to facilitate movement.

Wide ApplicationThe welding arc is super smooth to get perfect quality welds. The welding current regulation is broad to accommodate a variety of welding rods.

Kipor’s welding and generating dual use diesel generator sets: Power supply ranges from 2 to 10 kVA. Welding current ranges from 160 to 450A. This generator set is developed upon Kipor’s latest technology built upon Kipor’s 10 year history of manufacturing welder/generators.

The power supply for welding is self-driven. It can be used in a host of applications- railroading, highway construction, port operations, oil fields, chemical plants, building construction, agriculture and many more. Self- excitation and constant voltage enhance the generatorperformance. The lightweight and compact design facilitates on-site maneuverability and saves storage space.

The unit can achieve a perfect welding waveform voltage by utilizing IGBT and PWM technology. A non-fluctuating current produces high quality welding.

50/60 50/60 50/60

73 74

Rated generating output(KVA)Rated frequency (Hz)

Rated generating voltage(V)

Net weight(kg)Dimensions(mm)

Rated welding voltage(V)Rated welding current (A)

115/230 120/24065-70

1.5 2.050/60

160105

720x492x655

115/230 120/24065-70

1.5 2.0

160112

720x492x655

50/60Rated generating output(KVA)Rated frequency (Hz)

Rated generating voltage(V)

Net weight(kg)Dimensions(mm)

Rated welding voltage(V)Rated welding current (A)

115/230 120/24065-70

2.8 2.8 2.8 2.8 2.8 2.8

160130

840x535x650

115/230 120/24065-70

160147

840x535x650

115/230 120/24065-70

160191

930x545x740

Page 39: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

KDEDIESEL

We

ldin

g G

ene

rato

rW

eld

ing

Ge

nera

tor

KDE500STW3KDE500STW3KDE300STW3KDE300STW3

Three-phase modelsThree-phase models

KGE280EWKGE280EWKDE280EWKDE280EW

KDE Single-phase modelsKDE Single-phase models

Product Features KIPOR’s welding and generating dual use diesel generator sets:Power supply ranges from 2 to 10 kVA. Welding current ranges from 160 to 450A. This generator set is developed upon Kipor’s latest technology built upon Kipor’s 10 year history of manufacturing welder/generators

A lightweight and compact design improves on-site maneuverability and saves storage space. It has four durable casters to facilitate movement.

A new AVR (automatic voltage regulator) and damper winding further enhances the electricity production with extremely low voltage fluctuation and minimum waveform distortion.

Rated generating output(KVA)Rated frequency (Hz)

Rated generating voltage(V)

Net weight(kg)Dimensions(mm)

Rated welding voltage(V)Rated welding current (A)

400/230 416/24070-75

5 550/60

280520

1380x685x765

400/230 416/24075-78

10 10

Single 500 double 2x250850

1650x820x980

50/60Rated generating output(KVA)Rated frequency (Hz)

Rated generating voltage(V)

Net weight(kg)Dimensions(mm)

Rated welding voltage(V)Rated welding current (A)

115/230 120/24070-75

5 550/60

250225

1135x605x650

115/230 120/24070-75

5 5

250190

910x600x620

50/60

75 76

One unit, dual function

Simultaneous use

Perfect welding

Excellent electricity

Easy maneuverability

One Unit, Dual FunctionKIPOR original technology has been utilized to develop and advanced product with dual functions- welding and power generation

Simultaneous UseGenerating and welding can be operated simultaneously, while welding operation won’t impact an influence on the waveform and voltage of the generating operation.

Perfect WeldingThe unit can achieve a perfect waveform of the welding voltage by utilizing IGBT and PWM technology. The non-fluctuating welding current produces a high quality welding operation.

High Quality PowerNew A new AVR (automatic voltage regulator) and damper winding further enhances the electricity production with extremely low voltage fluctuation and minimum waveform distortion.

Easy ManeuverabilityA lightweight and compact design improves on-site maneuverability and saves storage space. It has four durable casters to facilitate movement.

Wide ApplicationThe welding arc is super smooth to get perfect quality welds. The welding current regulation is broad to accommodate a variety of welding rods.

Page 40: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

77 78

IGW E L D I N G

Product Features

High Quality PowerPowerKIPOR gasoline engine, 4-stroke, single cylinder, inclined cylinder air cooling& overhead valve.

Compact Structure, Easy to TransportCompact structure and all-steel body reduce the plate thickness with new drawing technology. Movablewheels make it easy to transport and it’s durable, resilient with low moving noise and wheel mark.

High Efficiency GeneratorKIPOR generator, brushless, permanent magnet without bearing. Easy to service, high efficiency, compact structure and light weight compared with brush, bearing wearing generators.

Control SystemKIPOR digital inverter delivers stable, pure sine wave output, reliable enough to power even the most sensitive electronic equipment.Short circuit regulator makes it easy to freely adjust welding parameters.Electric shock protection. It is safe to operate even in wet environment.

KIPOR welding& generating set is safe to use under the max. welding current no matter in cold or hot state. And utilizes generating & welding technology, providing high quality AC power at the same time of welding. It will serve you better with excellent performance of load acceptance, low fuel consumption, low emissions, low noise & cost effective.

Rated welding voltage (V)Rated frequency (Hz)

Rated welding current (A)

Welding load continuous ratioNet weight (kg)

IG150WIG150W

14021.2-25.6 21.2-26.8

25.650/60

50%85

IG185WIG185W

17026.8

50%105

50/60

Welding voltage (V)

IG WELDINGIG WELDINGAND GENERATING SETAND GENERATING SET

High Quality Power

Compact Structure, Easy to Transport

High Efficiency Generator

Control System

We

ldin

g G

ene

rato

rW

eld

ing

Ge

nera

tor

Page 41: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

Type KDE5000XW

Rated frequency

Engine

Generator set

Welding

Rated power

Rated current

Rated welding voltage

Rated welding current

Power factor

Rated voltage

Rated rotation speed

Phase No.

Welding voltage

Welding load continous ratio

Welding current adjustment range

Electrode diameter

Connection mode

Engine type

Bore x stroke

Com pression ratio

Rated power

Lubrication system

Lube oil brand

Starting system

Fuel type

Fuel tank capacity

Continous running time

Overall dimensions(LxWxH)

Dry weight

Noise

Structure type

Battery capacity

Lube capacity

Displacement

Insulation grade

Recifying mode

Excitation mode

Pole number

Engine model

Hz

kW

A

V

A

cosφ

V

r/m in

V

A

mm

mm

kW

L

hr

mm

kg

dB(A)/7m

V-Ah

L

L

6050

21.5

16.7/8.313/6.5

65-70

160

1.0

115/230 120/240

36003000

Single-phase three-loop Single-phase three-loop

25-30

60%

50-180

1.6-4.0

65-70

160

1.0

25-30

60%

50-180

1.6-4.0

Drive shaft ragid connection Drive shaft ragid connection

Single-cylinder, four-stroke, air-cooled,directed injection, diesel engine

6.35.7

Pressure splashed Pressure splashed

SF SAE10W-30, 15W-40 SF SAE10W-30, 15W-40 SF SAE10W-30, 15W-40

1.65 1.65

Recoil starter

0#(summer), -10#(winter),-35#(chill cold) diesel

13.5

6 6

720x492x655

105

77

Open-frame

13.5

12V-36Ah-

0.418

1-86x72

19:1

0.418

1-86x72

19:1

B

DiodeDiode

Separate excitation+AVR voltage regulator

2

B

2

KM186FAGXW

KDE5000EW

6050

21.5

16.7/8.313/6.5

115/230 120/240

36003000

6.35.7

Recoil starter or 12v electric starter

720x492x655

112

77

Open-frame

KM186FAGEW

KDE180EW

60

2.8

23.3/11.7

65-70

160

1.0

120/240

3600

Single-phase three-loop

25-30

60%

50-180

1.6-4.0

Single-cylinder, four-stroke, air-cooled,directed injection, diesel engine

6.3

Pressure splashed

1.65

0#(summer), -10#(winter),-35#(chill cold) diesel

13.5

6

840x535x650

147

78

Open-frame

≤360

12V-36Ah

0.418

1-86x72

19:1

B

Drive shaft ragid connection

Three-phase bridge+IGBT(PWM)

Self-excitation and constant voltage(with AVR)

2

KM186FAGEW

Recoil starter or 12v electric starter

Single-phase three-loop

65-70

160

1.0

25-30

60%

50-180

1.6-4.0

Drive shaft rigid connection

Pressure splashed

1.65

13.5

6

≤360

12V-36Ah

0.418

1-86x72

19:1

B

Three-phase bridge+IGBT (PWM)

Self-excitation and constant voltage (AVR)

2

KDE180XW

6050

2.82.8

23.3/11.724.3/12.2

115/230 120/240

36003000

6.35.7 5.7

Recoil starter

840x535x650

130

78

Open-frame

KM186FAGXW

Technical Data

50

2.8

24.3/12.2

115/230

3000

79 80

g/KW.hFuel consumption ratio

Type

Rated frequency

Engine

Generator set

Welding

Rated power

Rated current

Rated welding voltage

Rated welding current

Power factor

Rated voltage

Rated rotation speed

Phase No.

Welding voltage

Welding load continous ratio

Welding current adjustment range

Electrode diameter

Connection mode

Engine type

Bore x stroke

Com pression ratio

Rated power

Lubrication system

Lube oil brand

Starting system

Fuel type

Fuel tank capacity

Continous running time

Overall dimensions(LxWxH)

Dry weight

Noise

Structure type

Battery capacity

Lube capacity

Displacement

Insulation grade

Recifying mode

Excitation mode

Pole number

Engine model

Hz

kW

A

V

A

cosφ

V

r/m in

V

A

mm

mm

kW

L

hr

mm

kg

dB(A)/7m

V-Ah

L

L

g/KW.hFuel consumption ratio275.1 281.5 275.1 281.5 275.1 281.5 275.1 281.5

Page 42: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

81 82

KGE280EW

6050

55

41.7/20.843.5/21.7

70-75

250

1.0

115/230 120/240

36003000

Single-phase three-loop

25-30

60%

50-280

2.0-6.0

Drive shaft,rigid connection

V-twin,four-stroke, air-cooled,OHC, gasoline

1412

Pressure splashed

1.3

25

5

With wheels:910x600x760

190

78

Open-frame

12V-36Ah

0.688

2-78x72

8.5:1

B

Three-phase bridge+IGBT (PWM)

Self-excitation and constant voltage (AVR)

2

KG690GW

12v electric starter

Veicle lead-free petrol

KDE300STW3

6050

55

6.97.2

70-75

280

0.8(lag)

400/230 416/240

36003000

Single-phase four-line Y-connection

25-30

50%

55-300

2.0-6.0

Single-bearing disc-connection

Three-cylinder, in-lined, four-stroke, water-cooled,swirl chamber, diesel

14.713.3

Pressure splashed

4.5

0#(summer), -10#(winter),-35#(chill cold) diesel

30

8

1380x680x760

520

70

Silent

12V-45Ah

0.979

3-73x78

22.5:1

Brushless self excitation and constant volage(with AVR)

F

2

KD373GW

12V electric starter

Three-phase bridge+IGBT (PWM)

Technical DataType

Rated frequency

Engine

Generator set

Welding

Rated power

Rated current

Rated welding voltage

Rated welding current

Power factor

Rated voltage

Rated rotation speed

Phase No.

Welding voltage

Welding load continous ratio

Welding current adjustment range

Electrode diameter

Connection mode

Engine type

Bore x stroke

Com pression ratio

Rated power

Lubrication system

Lube oil brand

Starting system

Fuel type

Fuel tank capacity

Continous running time

Overall dimensions(LxWxH)

Dry weight

Noise

Structure type

Battery capacity

Lube capacity

Displacement

Insulation grade

Recifying mode

Excitation mode

Pole number

Engine model

Hz

kW

A

V

A

cosφ

V

r/m in

V

A

mm

mm

kW

L

hr

mm

kg

dB(A)/7m

V-Ah

L

L

g/KW.hFuel consumption ratio

Type

Rated frequency

Engine

Generator set

Welding

Rated power

Rated current

Rated welding voltage

Rated welding current

Power factor

Rated voltage

Rated rotation speed

Phase No.

Welding voltage

Welding load continous ratio

Welding current adjustment range

Electrode diameter

Connection mode

Engine type

Bore x stroke

Com pression ratio

Rated power

Lubrication system

Lube oil brand

Starting system

Fuel type

Fuel tank capacity

Continous running time

Overall dimensions(LxWxH)

Dry weight

Noise

Structure type

Battery capacity

Lube capacity

Displacement

Insulation grade

Recifying mode

Excitation mode

Pole number

Engine model

Hz

kW

A

V

A

cosφ

V

r/m in

V

A

mm

mm

kW

L

hr

mm

kg

V-Ah

L

L

g/KW.hFuel consumption ratio370 370

70-75

250

1.0

Single-phase three-loop

25-30

60%

50-280

2.0-6.0

Drive shaft,rigid connection

V-twin,four-stroke, water-cooled,swirl chamber,diesel

Pressure splashed

2.27

25

6.5

12V-45Ah

0.794

2-80x79

23:1

B

2

KDE280EW

6050

55

41.7/20.843.5/21.7

115/230 120/240

36003000

14.512.5

With wheels:1130x605x790

225

80

Open-frame

KM2V80GW

12v electric starter

0#(summer), -10#(winer),-35#(chill cold) diesel

285 297 270 276

SF SAE10W-30, 15W-40 SF SAE10W-30, 15W-40SF SAE10W-30, 15W-40

Single-phase three-loop

65-70

160

1.0

25-30

60%

50-180

1.6-4.0

Drive shaft ragid connection

Pressure splashed

1.65

0#(summer), -10#(winter),-35#(chill cold) diesel

15

6.5

≤360

12V-36Ah

0.418

1-86x72

19:1

Three-phase bridge+IGBT(PWM)

Self-excitation and constant voltage(with AVR)

B

2

KDE180TW

6050

2.82.8

23.3/11.724.3/12.2

115/230 120/240

36003000

6.35.7

12v electric starter

930x545x740

191

70

Silent

KM186FAGETW

275.1 281.5

Page 43: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

83 84

Technical DataType

Rated frequency

Engine

Generator set

Welding

Rated power

Rated current

Rated welding voltage

Rated welding current

Power factor

Rated voltage

Rated rotation speed

Phase No.

Welding voltage

Welding load continous ratio

Welding current adjustment range

Electrode diameter

Connection mode

Engine type

Bore x stroke

Com pression ratio

Rated power

Lubrication system

Lube oil brand

Starting system

Fuel type

Fuel tank capacity

Continous running time

Overall dimensions(LxWxH)

Dry weight

Noise

Structure type

Battery capacity

Lube capacity

Displacement

Insulation grade

Recifying mode

Excitation mode

Pole number

Engine model

Hz

kW

A

V

A

cosφ

V

r/m in

V

A

mm

mm

kW

L

hr

mm

kg

dB(A)/7m

V-Ah

L

L

g/KW.hFuel consumption ratio

SF SAE10W-30, 15W-40

75-78

Single torch:500 Dual torch:2x250

Single torch:90-500 Dual torch:55-250

0.8(lag)

Single-phase four-line Y-connection

30-38

60%

2.0-8.0

Single-bearing disc-connection

Three-cylinder, in-lined, four-stroke, water-cooled,direct injection, diesel

Pressure splashed

8.5

65

10

Silent

12V-65Ah

2.19

4-88x90

18.2:1

H

Brushless self excitation and constant volage(with AVR)

2

KDE500STW3

6050

1010

13.914.4

400/230 416/240

36003000

35.532.2

12V electric starter

1650x820x980

850

70

KD488GW

Three-phase bridge+IGBT (PWM)

230 235

Rated frequency

Rated voltage

Rated current

Rated rotation speed

Generating IG150W

Generator

Genset

Welding

Rated output power

Power factor

Circuit mode

Welding voltage

Welding load continous ratio

Rated welding voltage

Rated welding current

Welding current adjustment range

Core diameter

Pole No.

Cylinder structure type

Cylinder No.-Bore×Stroke

Displacement

Compression ratio

Rated power

Lube oil brand

Battery capacity

Engine minimum fuel consumption rate

Fuel type

Oil tank capacity

Fuel consumption rate(100%output power)

Panel type

Noise  (1m)  

Structure type

Fuel consumption rate(75%output power)

Net weight

Dimension(L×W×H)

Lube oil capacity

Lubrication system

Model

Insulation grade

Connection mode

Rectification mode

Motor type/Frequency type

Motor model

Hz

KVA

A

V

A

cosφ

V

r/m in

V

A

mm

mm

KW/(r/min)

L

L/h

L/h

mm

kg

dB(A)/7m

V-Ah

L

L

6050

2.5

20.8/10.410.9

25.6

140

1.0

230 120/240

Generating:3000,Welding:3600

Single phase, 3 circuit

21.2-25.6

50%

30-150

1.6-3.2

Outer rotor multipolar permanent magnet motor/IGBTdigital frequency transfer

KG280GETi

8.5:1

5.5/3600

SF,SAE 15W-40

Pressure flashed

1.1

374

Common panel

13.5

12V Electric starter

Vehicle lead-free gasoline

Single phase, 4 stroke, air cool, OHV,cylinder inclined

1-78×58

0.277

SCR

KD40 - W

Drive shaft rigid connection

B

2

g/KW.h

Starter system

12V 11Ah

14.5

2.18

2.86

14.5

2.76

3.62

65(no load)-75(full load)

85

Silent

735×515×650

IG185W

6050

3.0

25/12.513

26.8

170

1.0

230 120/240

Generating:3000,Welding:3600

Single phase, 3 circuit

21.2-26.8

50%

30-185

2.0-4.0

KG390GETi

8.5:1

7.7/3600

SF,SAE 15W-40

Pressure flashed

1.1

374

Common panel

12V Electric starter

Vehicle lead-free gasoline

1-88×64

0.389

SCR

KD70-W

Drive shaft rigid connection

B

2

12V 11Ah

65(no load)-75(full load)

105

Silent

810×570×695

Page 44: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

After developing various backup and prime power

systems, KIPOR is increasing its power systems

offerings and introducing innovative products for

industry.

The KIPOR mobile light towers can be utilized in a

variety of situations such as construction sites,

disaster recovery,

Industry, mining, and event lighting

All KIPOR light towers are equipped with KIPOR high

quality digital generators or advanced conventional

models. The new mobile light towers feature high wind

resistance and a wide area of illumination.

KIPOR’ s compact mobile light towers are available

with 1000, 4000, and 6000 halide lights, designed for a

compact and efficient installation. You can choose the

suitable power and light levels to fit your requirements.

Both the telescoping mast and illumination angle of the

lights can be easily adjusted giving the operator great

flexibility in lighting the area. The tower is designed to

be user friendly in terms of both operation and

handling.

1 1. 400 or 1000W metal halide lamps

2. Optimally designed lamp bracket, easily transportable

3. Advanced digital generator provides a high quality power supply

4. Digitally controlled inverter technology ensures a stable power output

5. Integrated control panel makes operation easy and convenient

6. Both recoil and electric starting systems

7. Modular lamps

KIPOR IGLA3000

2 KIPOR IGLB3000

1. 400 or 1000W metal halide lamps

2. Optimally designed lamp bracket, easily transportable

3. Advanced digital generator provides a high quality power supply

4. Digitally controlled inverter technology ensures a stable power output

5. Integrated control panel makes operation easy and convenient

6. Both recoil and electric starting systems

1. 400 or 1000W metal halide lamps

2. Optimally designed lamp bracket, easily transportable

3. Advanced digital generator provides a high quality power supply

4. Digitally controlled inverter technology ensures a stable power output

5. Integrated control panel makes operation easy and convenient

6. Both recoil and electric starting systems

3 KIPOR IGLB6000

4 KIPOR KLTD11000T

1. 1000W metal halide lamp applicable for all climates

2. Manual and automatic telescopic link

3. Advanced technology ensures a high quality power supply

4. Folding mast facilitates storage

5. Optimally designed lamp bracket makes transporting easy and safe.

1. Die-cast aluminum bracket

2. Adjustable windshield

3. Protective front shield

4. Adjustable swivel head

5. Built-in ON-OFF switch with two swivel heads

6. Fixed metal tripod with telescopic link

7. Folding bracket facilitates storage

8. 500W 118mm metal halide lamp

5KLBH500-1KLBH500-2

LIGHT TOWERPORTABLEPORTABLELIGHT TOWER

Page 45: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

IGLB modelsIGLB models

Product Features

IGLBLIGHT TOWER

1000, 4000, or 6000W halide lights

Optimally designed lamp bracket for easy transport

Advanced digital generator provides a high quality power supply

Integrated control panel makes operation easy and convenient

The newly launched mobile light towers feature excellent wind resistance and a wide area of illumination.

KIPOR’s compact mobile light towers are available with 1000, 4000, and 6000 halide lights, designed for a compact and efficient installation. You can choose the suitable power and light levels to fit your require-ments.

Both the telescoping mast and illumination angle of the lights can be easily adjusted giving the operator great flexibility in lighting the area. The tower is designed to be user friendly in terms of both operation and handling.

The KIPOR mobile light towers can be utilized in a variety of situations such as construction sites, disaster recovery, industry, mining, and event lighting. All the light towers are equipped with KIPOR high quality digital or conventional generators.

Wide Lighting AreaKipor’s light tower parallel lamp structure is more efficient than competitive lighting systems and provides up to 50% more light output. The unique top structure of the lamp shade directs up to 10% of previously wasted upward light directly to the work site.

Easy for TransportThe generator powering the light tower can be used a backup power in emergency situations. There are two receptacles on the light tower mast. You can switch off the lights and then connect another electrical load to get a quality output from the generator. The receptacles can be configured to your voltage requirement of 110, 120., 230, or 240V.

Dual ApplicationThe generator inside the light tower can be used as back-up power for emergency applications.There are two receptacles on the mast of the light tower. You can switch off the lights and then connect another electrical load to get a quality power output from the generator. The receptacles can be configured to your voltage requirements of 110V,120V, 23OV or 240V.

Advantages of Halide LampThe internal structure of the metal halide lamp is unique. The light is produced through the discharge of its internal gasses. There is no filament to break or deteriorate over time and no bulb to throw away.

Safe operationThe mast incorporates a safety feature by not permitting the mast to be raised unless the footbrake is on. If the footbrake is release, the mast will automatically lower to the travel position. The light tower trolley has stabilizers to keep the light tower steady on all surfaces.

Lig

ht T

ow

er

Lig

ht T

ow

er

IGLB3000IGLB3000 IGLA3000IGLA3000

Lamp power (W)-No.of lampFloodlight model

Total power of the lamps (W)

Net weight (kg)

Luminuous flux (lm)Mast 4 stages lifting mast 4 stages lifting mast4 stages lifting mast

1600/2000144000/220000

400-4/1000-2KLB400-4/KLB1000-2 KLB1000-4

135/140

IGLB6000IGLB6000

1000110000

1000-1KLA1000-1

150

4000440000

1000-4

220

The newlyfeature exarea of illu

KIPOR’s cavailable lights, desinstallatiopower andments.

Both the tangle of thgiving thethe area.friendly inhandling.

87 88

Page 46: Generators - KIPORUK portable series.pdf · KD09 1 Single phase KG140 40×30 0.03768 8.5∶1 1.0/6000 Above SF SAE 10W-30 0.15 T.C.I UR5 Recoil starter-Vehicle lead-free petrol 450

89 90

Technical Data

IGLBLIGHT TOWER

Generator model

Floodlight model

Lifting limit of the mast

Inclination

Windproof ability

Total power of the lamps

Model

Rated frequency

Rated voltage

Rated current

Rated power

Max. power

Fuel

Fuel consumption

Fuel tank capacity

Continuous running time

Mast

Dimension (LxWxH) (after retreating)

Dry weight

Dry weight

Lamp power (W) -No. of lamp

Trolley

Generator set

Luminuous flux

mm

W

W

Hz

V

A

kVA

kVA

L/h

L

h

mm

kg

kg

lm

6050

120/240230

23.3/11.712.2

120/240230

23.3/11.712.2

120/240230

23.3/11.712.2

IGLB3000

IG3000

2000-4840 2300-5190

≤10 degrees

≤6 grade

1600

144000 220000 110000

4 stages lifting mast

1180x790x2300

135

2.8

3.0

1.5

13

8.6

57

1000-1

400-4

6050

KLB400-4

IGLA3000

KLA1000-1

IG3000

1.27

13

10.2

6050

140 150

IGLB3000

KLB1000-2

IG3000

≤10 degrees ≤10 degrees

≤6 grade ≤6 grade

4 stages lifting mast 4 stages lifting mast

2.8

3.0

2.8

3.0

120/240230

45.8/22.923.9

5.5

6

1.86

13

7

57 57

4900

1180x790x2100 1180x790x2300

2000 1000

square,metal halide lamp

IGLB6000

KLA1000-4

IG6000

3.7

96.5

22

6

6050

KLTD11000T

KLT1500-4

KDE11T

4800-9000

≤10 degrees

≤6 grade

660000

3 stages lifting mast

3600x1250x1680

700

8.5 10.5

9.5 11.5

Diesel

-

4

70

17.5

-

1500-4

60

240230

50

1000-2 1000-1

2100-4900

440000

220

≤10 degrees

≤6 grade

4 stages lifting mast

1180x790x2100

4000 6000

1000-4

Vehicle lead-free petrol Vehicle lead-free petrol Vehicle lead-free petrol