general notes - m.j. dixon construction limited€¦ · stc rating: 35 1" = 1'-0" 1...

10
AREA OF WORK NOT IN CONTRACT AREA OF WORK GEORGE BROWN COLLEGE 200 KING STREET EAST, FACILITIES MANAGEMENT ROOM 209B TORONTO ONTARIO M5T 2T9 TEL: (416) 415 - 5000 FAX: (416) 415 4488 www.georgebrown.ca APPROVED BY DRAWN SCALE DWG NAME PROJECT ADDRESS CLIENT PROJECT PLOT DATE DATE PROJECT NO DWG NO REV NOTE DATE DESCRIPTION SIGN DAT 3/32" = 1' - 0" 10/23/2017 2:57:07 PM PROPOSED HR RENOVATION HUMAN RESOURCE 100 HUMAN RESOURCE BENJAMIN 10/03/17 2017 - 044 LOCATION AND SITE PLAN 500 MACPHERSON GENERAL NOTES 1. SITE VISIT IS REQUIRED BY CONTRACTOR TO VERIFY SITE CONDITIONS. CONTACT GBC FOR CLARIFICATION IF REQUIRED. 2. MAKE GOOD AFFECTED AREAS DAMAGED DURING DEMOLITION. 3. PATCH & REPAIR AND MAKE GOOD ALL EXISTING DRYWALL PERIMETER WALLS, CORE WALLS, CEILINGS,AND BULKHEADS. MAKE GOOD AND PREPARE SURFACES TO RECEIVE NEW FINISHES. 4. CONTRACTOR TO PROVIDE ADEQUATE BLOCKING TO SUPPORT MILLWORK. PROVIDE BLOCKING AS REQUIRED 5. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ELECTRICAL WORK. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CHASES, OPENINGS INCLUDING FLOOR TRENCHING OF EXISTING CONCRETE SLABS, AND PATCHING AS MAY BE REQUIRED BY CABLING TRADES. REFER TO DWGS, AND REVIEW THE REQUIREMENTS WITH TRADES. 6. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE TO KEEP ALL ACCESS AREAS CLEAN, REMOVE GARBAGE AND CLEAN DAILY AND AS REQUIRED UPON COMPLETION OF THE PAINTING CONTRACTORS WORK. 7. THE GENERAL CONTRACTOR SHALL REMOVE ALL PROTECTIVE MATERIALS. THE GENERAL CONTRACTOR SHALL ARRANGE A PROFESSIONAL CLEANING SERVICE TO CLEAN/WIPE DOWN ALL SURFACES, INCLUDING WALLS, AND MILLWORK. 8. ACCESS TO THE SITE FOR MATERIALS, WORK FORCES AND FOR GARBAGE REMOVAL IS TO BE CO - ORDINATED THROUGH GBC. 9. MAKE GOOD ALL EXISTING WALL SURFACES READY TO RECEIVE NEW FINISHES. 10. THE CONTRACTOR IS RESPONSIBLE TO INSTALL ALL PRODUCTS INCLUDING ELECTRICAL PRODUCTS ACCORDING TO THE MANUFACTURER’S INSTRUCTIONS AND TO MEET ANY CERTIFIED LISTINGS REQUIRED OF THE MANUFACTURER. 11. ALL LOCATIONS OF OUTLETS TO BE MARKED OUT ON SITE FOR GBC APPROVAL PRIOR TO INSTALLATION. 12. SITE SUPERVISOR TO BE ON SITE WHENEVER CONSTRUCTION IS IN PROGRESS. NO SUB CONTRACTORS TO WORK WITHOUT A SITE SUPERVISOR ON SITE. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING THE ABOVE FORCES WHERE SUCH WORK AFFECTS THE PROGRESS. 3/32" = 1'-0" 1 SITE PLAN & WORK AREA NORTH LOCATION OF SITE 500 MACPHERSON AV.

Upload: others

Post on 22-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GENERAL NOTES - M.J. Dixon Construction Limited€¦ · stc rating: 35 1" = 1'-0" 1 mtl. stud wall to u/s deck 1" = 1'-0" 2 mtl. stud wall to u/s of ceiling 1" = 1'-0" 3 glazed shopfront

AREA

OF

WORKNOT IN CONTRACT

AREA OF WORK

GEORGE BROWN COLLEGE

200 KING STREET EAST,

FACILITIES MANAGEMENT ROOM 209B

TORONTO ONTARIO M5T 2T9

TEL: (416) 415-5000 FAX: (416) 415 4488

www.georgebrown.ca

APPROVED BY DRAWN

SCALEDWG NAMEPROJECT ADDRESS

CLIENT PROJECT

PLOT DATE

DATE PROJECT NO

DWG NO

REV NOTE

DATE DESCRIPTION

SIGN

DAT

3/32" =1'-0"

10/23/20172:57:07 PM

PROPOSED HR RENOVATIONHUMAN RESOURCE

100

HUMANRESOURCE

BENJAMIN10/03/17 2017-044

LOCATION AND SITE PLAN500 MACPHERSON

GENERAL NOTES

1. SITE VISIT IS REQUIRED BY CONTRACTOR TO VERIFY SITE CONDITIONS. CONTACT GBC FOR CLARIFICATION IF REQUIRED.

2. MAKE GOOD AFFECTED AREAS DAMAGED DURING DEMOLITION.3. PATCH & REPAIR AND MAKE GOOD ALL EXISTING DRYWALL

PERIMETER WALLS, CORE WALLS, CEILINGS,AND BULKHEADS. MAKE GOOD AND PREPARE SURFACES TO RECEIVE NEW FINISHES.

4. CONTRACTOR TO PROVIDE ADEQUATE BLOCKING TO SUPPORT MILLWORK. PROVIDE BLOCKING AS REQUIRED

5. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ELECTRICAL WORK. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CHASES, OPENINGS INCLUDING FLOOR TRENCHING OF EXISTING CONCRETE SLABS, AND PATCHING AS MAY BE REQUIRED BY CABLING TRADES. REFER TO DWGS, AND REVIEW THE REQUIREMENTS WITH TRADES.

6. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE TO KEEP ALL ACCESS AREAS CLEAN, REMOVE GARBAGE AND CLEAN DAILY AND AS REQUIRED UPON COMPLETION OF THE PAINTING CONTRACTORS WORK.

7. THE GENERAL CONTRACTOR SHALL REMOVE ALL PROTECTIVE MATERIALS. THE GENERAL CONTRACTOR SHALL ARRANGE A PROFESSIONAL CLEANING SERVICE TO CLEAN/WIPE DOWN ALL SURFACES, INCLUDING WALLS, AND MILLWORK.

8. ACCESS TO THE SITE FOR MATERIALS, WORK FORCES AND FOR GARBAGE REMOVAL IS TO BE CO-ORDINATED THROUGH GBC.

9. MAKE GOOD ALL EXISTING WALL SURFACES READY TO RECEIVE NEW FINISHES.

10. THE CONTRACTOR IS RESPONSIBLE TO INSTALL ALL PRODUCTS INCLUDING ELECTRICAL PRODUCTS ACCORDING TO THE MANUFACTURER’S INSTRUCTIONS AND TO MEET ANY CERTIFIED LISTINGS REQUIRED OF THE MANUFACTURER.

11. ALL LOCATIONS OF OUTLETS TO BE MARKED OUT ON SITE FOR GBC APPROVAL PRIOR TO INSTALLATION.

12. SITE SUPERVISOR TO BE ON SITE WHENEVER CONSTRUCTION IS IN PROGRESS. NO SUB CONTRACTORS TO WORK WITHOUT A SITE SUPERVISOR ON SITE.

THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING THE ABOVE FORCES WHERE SUCH WORK AFFECTS THE PROGRESS.

3/32" = 1'-0"1

SITE PLAN & WORK AREA

NORTH

LOCATION OF SITE

500 MACPHERSON AV.

Page 2: GENERAL NOTES - M.J. Dixon Construction Limited€¦ · stc rating: 35 1" = 1'-0" 1 mtl. stud wall to u/s deck 1" = 1'-0" 2 mtl. stud wall to u/s of ceiling 1" = 1'-0" 3 glazed shopfront

NOTE: PROVIDE LATERAL BRACING WIRES AS REQUIRED BY CODE EACH DIRECTION

MAIN TEES @ 48" O.C. TYPICAL

CROSS TEES @ 24" O.C. TYPICAL

HANGER WIRES @ 48" O.C., TYPICAL

BOTTOM OF SLAB OR BEAM

SUSPENDED ACOUSTICAL TILE CEILING

P2

5/8" GYPSUM BD. ON BOTH SIDES OF 3 5/8" METAL STUDS (20)GA @16" O.C

3" SOUND ATTENUATION BLANKETS

BOTTOM RUNNER

U/S SLAB

FINISHED FLOOR

PERIMETER ACOUSTICAL SEALANT BOTH SIDES

TOP CHANNEL

3/4"

3 3/4"

3/4"

5"

PERIMETER ACOUSTICAL SEALANT BOTH SIDES

NOTE: PROVIDE LATERAL BRACING WIRES AS REQUIRED BY CODE EACH DIRECTION

MAIN TEES @ 48" O.C. TYPICAL

CROSS TEES @ 24" O.C. TYPICAL

HANGER WIRES @ 48" O.C., TYPICAL

BOTTOM OF SLAB OR BEAM

SUSPENDED ACOUSTICAL TILE CEILING

P1

5/8" GYPSUM BD. ON BOTH SIDES OF 3 5/8" METAL STUDS (20)GA @16" O.C

3" SOUND ATTENUATION BLANKETS

BOTTOM RUNNER

U/S SLAB

FINISHED FLOOR

PERIMETER ACOUSTICAL SEALANT BOTH SIDES

TOP CHANNEL

3/4"

3 3/4"

3/4"

5"

NOTE: PROVIDE LATERAL BRACING WIRES AS REQUIRED BY CODE EACH DIRECTION

MAIN TEES @ 48" O.C. TYPICAL

CROSS TEES @ 24" O.C. TYPICAL

HANGER WIRES @ 48" O.C., TYPICAL

BOTTOM OF SLAB OR BEAM

SUSPENDED ACOUSTICAL TILE CEILING

P3

5/8" GYPSUM BD. ON BOTH SIDES OF 3 5/8" METAL STUDS (20)GA @16" O.C

3" SOUND ATTENUATION BLANKETS

U/S SLAB

FINISHED FLOOR

TOP CHANNEL

3/4"

3 3/4"

3/4"

5"

PERIMETER ACOUSTICAL SEALANT BOTH SIDES

1" (nom)

3/8" TEMPERED GLASS

2-PIECE SINGLE GLAZED CHANNELGLA

SS

SIZ

E D

IM 'Y

' +

30 m

m

DIM

EN

SIO

N 'Y

'

PROVIDE METAL STUD LATERAL SUPPORT AS REQUIRED

HUMAN RESOURCE RENO ROOM F101

GEORGE BROWN COLLEGE

200 KING STREET EAST,

FACILITIES MANAGEMENT ROOM 209B

TORONTO ONTARIO M5T 2T9

TEL: (416) 415-5000 FAX: (416) 415 4488

www.georgebrown.ca

APPROVED BY DRAWN

SCALEDWG NAMEPROJECT ADDRESS

CLIENT PROJECT

PLOT DATE

DATE PROJECT NO

DWG NO

REV NOTE

DATE DESCRIPTION

SIGN

DATAs indicated

10/23/20172:57:07 PM

PROPOSED HR RENOVATIONHUMAN RESOURCE

101

HUMANRESOURCE

Author10/04/17 2017-044

SPECS500 MACPHERSON

SPECIFICATION NOTES

FIRESTOPPING AND SMOKE SEALS

ALL PENETRATIONS, OPENINGS AND JOINTS IN RATED WALLS TO BE SEALED USING FIRESTOPPING AND SMOKE SEALS

HOLLOW METAL FRAMES

MINIMUM BASE STEEL THICKNESS TO BE 16 GAUGE FINISH: PRIMED AND

GYPSUM BOARD

5/8" GYPSUM BOARD TO BE USED FOR ALL WALLS UNLESS OTHERWISE NOTED1/2" GYPSUM BOARD TO BE USED FOR ALL CEILINGS AND BULKHEAD CONSTRUCTIONACCESS DOOR PANEL IN GYPSUM BOARD CEILINGS/BULKHEADS TO BE MIFAB, SERIES-CAD FLUSH, PAINTED TO MATCH CEILING COLOUR

ACOUSTIC CEILINGS

ACOUSTIC TILE - MILLENNIA CLIMA PLUS, 2’x4’x3i", SQUARE LAY-IN EDGE, WHITE, BY CGC INC.SUSPENSION SYSTEM - DONN DX/DXL, LAY-IN BY CGC LOW SHEEN WHITE ENAMEL FINNISHCENTRICITEE SHADOWLINE WALL ANGLE MS174 PROFILE, LOW SHEEN WHITE ENAMEL FINISH

CARPET

MOHAWK, BENDING EARTH COLLECTION, COL. DATUM 7879 BASALT.

WALL BASE

WALL BASE: CARPET BASE- TO MATCH EXISTING (4”).COLOUR: TO 40 BLACK. CORRIDOR SIDE MATCH EXISTING BASE.PROVIDE REDUCER EDGE STRIP AND THRESHOLDS AS REQUIRED ALL FLOOR PREPARATION TO PROVIDE SMOOTH LEVEL SUBSTRATE FOR NEW INSTALLATION TO BE INCLUDED

PAINTING

ALL PAINTING TO COMPLY WITH CPCA PAINTING SPECIFICATION MANUALLATEX EGGSHELL: FOR ALL CONCRETE, CONCRETE BLOCK,GYPSUM BOARD WALLSLATEX FLAT: GYPSUM BOARD CEILINGEPOXY SEMI-GLOSS: METAL FABRICATIONS AND GALVANIZEDSTEEL (INCLUDED HOLLOW METAL DOORS AND FRAMES)COLOURS: FIELD COLOUR BENJAMIN MOORE IVORY WHITE, CC-130 COLLECTION CLASSICDOOR FRAMES - BENJAMIN MOORE METROPOLIS CC546 , PRIME TIME PAINTS

GLAZED PARTITIONS

SOLARE ACOUSTIC SINGLE GLAZED PARTITION BY AVANTI SYSTEMS(WWW.AVANTISYSTEMSUSA.COM)MAXIMUM GLAZING PANEL WIDTH: 60" MAX.MAXIMUM GLAZING PANEL HEIGHT: FULL HEIGHT UP TO 12 FEETGLAZING AVAILABLE: 3/8" CLEAR TEMPERED.AVAILABLE GLAZING TYPES: CLEAR TEMPERED.DOOR WIDTH: 38" MAX.STANDARD FINISHES AVAILABLE: TBASTC RATING: 35

1" = 1'-0"1

MTL. STUD WALL TO U/S DECK 1" = 1'-0"

2MTL. STUD WALL TO U/S OF CEILING

1" = 1'-0"3

GLAZED SHOPFRONT WITH GB WALLTO U/S DECK

12" = 1'-0"4

LIGHT FIXTURE SPEC

Page 3: GENERAL NOTES - M.J. Dixon Construction Limited€¦ · stc rating: 35 1" = 1'-0" 1 mtl. stud wall to u/s deck 1" = 1'-0" 2 mtl. stud wall to u/s of ceiling 1" = 1'-0" 3 glazed shopfront

OFFICE

114

?

BOARDROOM

104

CORRIDOR

101

102

A

BC

D

E F

A

B

C2

E2

E5

E4

E3

103

STAFF LOUNGE

HUMAN RESOURCES

119

MECH

ROOM

STAIR 5EXEC.DIR. - HR

ENTRANCE

C

TRAINING

FMALE

WR

OFFICE

OFFICE

FILING

OFFICE

OPEN

OFFICE

OFFICE

B

B

STAIR 2

STAIR 1

EXIT 3

A

105

C

115

D

B

112

MALE

WR

36

24

36

24

36

24

36

24

36

24

36

24

36

24

36

24

36

24

3030

30

30

3030 303030

3030

30

30

30

30

30

TD

TD

TD

TD

DEMO ASSEMBLIES SHOWN IN DOTTED.

REMOVE EXISTING FLOORING AND DISPOSE.

DEMO ASSEMBLIES SHOWN IN DOTTED.

REMOVE EXISTING DOOR AND MAKE GOOD

REMOVE EXISTING DOOR AND MAKE GOOD

DEMO ASSEMBLIES SHOWN IN DOTTED.

DEMO ASSEMBLIES SHOWN IN DOTTED.

DEMO WALL. MAKE GOOD MAKE GOOD DISTURBED AREA

REMOVE EXISTING CARPET TILES FOR REUSE

REMOVE EXISTING CARPET TILES FOR REUSE

REMOVE EXISTING CARPET TILES FOR REUSE

DEMO ASSEMBLIES SHOWN IN DOTTED.

DEMO ASSEMBLIES SHOWN IN DOTTED.

REMOVE EXISTING DOOR AND MAKE GOOD

RELOCATE EXISTING EMERGENCY PHONE AND DEFIBRILLATOR TO CORRIDOR AS SHOWN

EXISTING ALARM BELL TO BE RELOCATED

EXISTING SIGNAGE TO BE REMOVED AND DISCARDED

EXISTING ALARM PANEL TO REMAIN

DEMO ASSEMBLIES SHOWN IN DOTTED.

GEORGE BROWN COLLEGE

200 KING STREET EAST,

FACILITIES MANAGEMENT ROOM 209B

TORONTO ONTARIO M5T 2T9

TEL: (416) 415-5000 FAX: (416) 415 4488

www.georgebrown.ca

APPROVED BY DRAWN

SCALEDWG NAMEPROJECT ADDRESS

CLIENT PROJECT

PLOT DATE

DATE PROJECT NO

DWG NO

REV NOTE

DATE DESCRIPTION

SIGN

DAT 1" = 10'-0"

10/23/20172:57:08 PM

PROPOSED HR RENOVATIONHUMAN RESOURCE

102

HUMANRESOURCE

Benjamin09/27/17 2017-044

DEMOLITION500 MACPHERSON

1" = 10'-0"1

DEMO

NORTH

0 20 30 4010

GRAPHIC SCALE

Page 4: GENERAL NOTES - M.J. Dixon Construction Limited€¦ · stc rating: 35 1" = 1'-0" 1 mtl. stud wall to u/s deck 1" = 1'-0" 2 mtl. stud wall to u/s of ceiling 1" = 1'-0" 3 glazed shopfront

OFFICE

114

?

STAFF LOUNGE

HUMAN RESOURCES

119

MECH

ROOM

STAIR 5EXEC.DIR. - HR

ENTRANCE

C

TRAINING

FMALE

WR

OFFICE

OFFICE

FILING

OFFICE

OPEN

OFFICE

OFFICE

B

B

STAIR 2

STAIR 1

EXIT 3

A

105

C

115

D

B

112

MALE

WR

Tectonic Cop

yright 2007

48

30

30

C C

30C

T ectonic Cop yright 2007

48

30

30C

C

30

C

30

C

48

30 36

24

CCC

30

C

48

3036

24

CC C

48

30 36

24

CCC

48

3036

24

CC C

48

30

36

24C C

C

48

30 36

24

CCC

48

3036

24

CC C

48

3036

24

CC C

48

C

30

C

30

C

48

30

36

24C C

C

3030

30

30

3030 303030

3030

30

30

30

30

30

NEW PROJECTOR, AND SCREEN BY GBC.

-

EXISTING T-BAR GRID TO REMAIN. INSTALL NEW CEILING TILES

EXISTING LIGHT FIXTURES TO REMAIN. CHANGE LENSES AND RE-LAMP

EXISTING T-BAR GRID TO REMAIN. INSTALL NEW CEILING TILES

EXISTING T-BAR GRID TO REMAIN. INSTALL NEW CEILING TILES

EXISTING T-BAR GRID TO REMAIN. INSTALL NEW CEILING TILES

REMOVE LIGHT FIXTURES AND DISPOSE

REMOVE LIGHT FIXTURES AND DISPOSE

DEMO EXISTING T-BAR CEILING

CLEAN AND REUSE EXISTING SUPPLY GRILLS

DEMO EXISTING BULKHEAD

DEMO EXISTING BULKHEAD

EXISTING T-BAR CEILING TO REMAIN

EXISTING LIGHT FIXTURES TO REMAIN. CHANGE LENSES AND RE-LAMP

CLEAN AND REUSE EXISTING SUPPLY GRILLS

TO RTU

TO AC3

EXISTING LINEAR DIFFUSER TO REMAIN

HEAT/ SMOKE DETECTOR TO REMAIN. PROTECT FROM DAMAGE DURING CONSTRUCTION

HEAT/ SMOKE DETECTOR TO REMAIN. PROTECT FROM DAMAGE DURING CONSTRUCTION

GEORGE BROWN COLLEGE

200 KING STREET EAST,

FACILITIES MANAGEMENT ROOM 209B

TORONTO ONTARIO M5T 2T9

TEL: (416) 415-5000 FAX: (416) 415 4488

www.georgebrown.ca

APPROVED BY DRAWN

SCALEDWG NAMEPROJECT ADDRESS

CLIENT PROJECT

PLOT DATE

DATE PROJECT NO

DWG NO

REV NOTE

DATE DESCRIPTION

SIGN

DAT 1" = 10'-0"

10/23/20172:57:08 PM

PROPOSED HR RENOVATIONHUMAN RESOURCE

103

HUMANRESOURCE

Author10/03/17 2017-044

RCP DEMO500 MACPHERSON

1" = 10'-0"1

EXISTING RCP

NORTH

0 16 24 328

GRAPHIC SCALE

Page 5: GENERAL NOTES - M.J. Dixon Construction Limited€¦ · stc rating: 35 1" = 1'-0" 1 mtl. stud wall to u/s deck 1" = 1'-0" 2 mtl. stud wall to u/s of ceiling 1" = 1'-0" 3 glazed shopfront

OFFICE

114

?

B

B

STAIR 2

STAIR 1

A

105

C

115

D

B

112

MALE

WR

48

30

30

C C

30C

48

30

30C

C

30

C

30

C

48

30 36

24

CCC

30

C

48

303624

CC C

48

30 36

24

CCC

48

3036

24

CC C

48

30

36

24

C

48

30 36

24

CCC

48

3036

24

CC C

48

3036

24

CC C

48

C

30

C

30

C

48

30

36

24C C

C

3030

30

30

3030 303030

3030

30

30

30

30

30

UP

UP

1

106

FEMALE

WASHROOM

?

149 SF

MALE

WASHROOM

?

131 SF

PUBLIC

CORRIDOR

?STAIR

13

136 SF

MECH

119

129 SF

OFFICE

101-P

189 SF

OFFICE

101-R

127 SF

SHRC OFFICE

101-G

107 SF

FILE

101-A

171 SF

OFFICE

101-E

159 SF

OFFICE

101-B

123 SF

?

??

?P

OFFICE

101-F

202 SF

OFFICE

110-A

274 SF

OFFICE

110-C

170 SF

INTERVIEW

ROOM

114

117 SF

OPEN OFFICE

110

998 SF

WC

109

44 SFOFFICE

110-E

131 SF

LUNCH

106

428 SF

PUBLIC

CORRIDOR

?

OFFICE

101-Q

121 SF

FILLING

110-G

156 SF

TRAINING

ROOM

101-N

400 SF

H&S OFFICE

101-M

86 SF

LRM OFFICE

101-L

107 SF

SHRC OFFICE

101-K

106 SF

SHRC OFFICE

101-J

106 SF

RECEPTION

101

360 SF

BOARDROOM

115

368 SF

OFFICE

101-C

312 SF

OFFICE

101-D

157 SF

SHRC OFFICE

101-H

107 SF

OPEN OFFICE

101

196 SF

8" 3'-4" 2'-1" 7'-4"

5'-9 1/2" 14'-11 3/4" 4'-7 1/2" 9'-8" 5" 11'-0 1/4"

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ EQ EQ

EQ EQ EQ

EQ EQ

5"

6" 3'-0

"9'

-6 1

/4"

5"6'

-4"

EQ

EQ

EQ

EQ

EQ

EQ

4'-0" 3'-0" 6"

8'-5 1/2" 8'-2 1/4" 5" 8'-2 1/4" 4'-7 1/2" 8'-6"

7'-9

3/4

"

18'-2

"

1'-9 3/4" 6"

EQ EQ

9'-7 1/2" 6" 5 1/2" 3'-0" 7'-6 1/4"

7'-7

1/4

"3'

-0"

6"7

3/4"

2'-0

1/2

"4'

-10

1/2"

3'-0

"6

1/4"

6'-1

1 3/

4"3'

-0"

6"1'

-3"

Room

V106

0 SF

ELEVATOR

V107

64 SF

STAIR

V108

115 SF

STAIR

V116

205 SF101B2

101C

101A

101F

101B

PRINTER

AREA

C-101P

1013

106

-

P2

P2P3

P2

P3

P3

P2

P1

P1P1

P1

P3

P3

180

101M

101G 101H

101L

101K

101J

RELOCATED ALARM BELL

P2

2'-2

"1'

-1 1

/2"

ROOM TO BE REPAINTED

ROOM TO BE REPAINTED

ROOM TO BE REPAINTED

ROOM TO BE REPAINTED

ROOM TO BE REPAINTED

GEORGE BROWN COLLEGE

200 KING STREET EAST,

FACILITIES MANAGEMENT ROOM 209B

TORONTO ONTARIO M5T 2T9

TEL: (416) 415-5000 FAX: (416) 415 4488

www.georgebrown.ca

APPROVED BY DRAWN

SCALEDWG NAMEPROJECT ADDRESS

CLIENT PROJECT

PLOT DATE

DATE PROJECT NO

DWG NO

REV NOTE

DATE DESCRIPTION

SIGN

DAT 1" = 10'-0"

10/23/20172:57:08 PM

PROPOSED HR RENOVATIONHUMAN RESOURCE

104

HUMANRESOURCE

Benjamin09/27/17 2017-044

NEW WORKS500 MACPHERSON

NORTH

0 20 30 4010

GRAPHIC SCALE

1" = 10'-0"1

NEW WORK

Page 6: GENERAL NOTES - M.J. Dixon Construction Limited€¦ · stc rating: 35 1" = 1'-0" 1 mtl. stud wall to u/s deck 1" = 1'-0" 2 mtl. stud wall to u/s of ceiling 1" = 1'-0" 3 glazed shopfront

STAIR 2

STAIR 1

105

2

1

106

OFFICE

101-F

202 SF

OFFICE

101-E

159 SF

OFFICE

101-D

157 SF

OFFICE

101-C

312 SF

OFFICE

101-B

123 SF

FILE

101-A

171 SF

OPEN OFFICE

101

196 SF

SHRC OFFICE

101-G

107 SF

SHRC OFFICE

101-H

107 SF

SHRC OFFICE

101-J

106 SF

MECH

119

129 SF

LUNCH

106

428 SF

SHRC OFFICE

101-K

106 SF

LRM OFFICE

101-L

107 SF

H&S OFFICE

101-M

86 SF

RECEPTION

101

360 SF

OFFICE

101-P

189 SF

OFFICE

101-Q

121 SF

OFFICE

101-R

127 SF

TRAINING

ROOM

101-N

400 SF

2

106

?

??

?P

3

106

-

NEW ACT CEILING @8'AFF

INSTALL NEW ELECTRICAL FIXTURE -SEE SPEC (TYP)

EXISTING LIGHT FIXTURES TO REMAIN. CHANGE LENSES AND RE-LAMP

CLEAN AND REUSE EXISTING SUPPLY GRILLS

EXISTING T-BAR GRID TO REMAIN. INSTALL NEW CEILING TILES

EXISTING LIGHT FIXTURES TO REMAIN. CHANGE LENSES AND RE-LAMP

NEW ACT CEILING @8'AFF

GEORGE BROWN COLLEGE

200 KING STREET EAST,

FACILITIES MANAGEMENT ROOM 209B

TORONTO ONTARIO M5T 2T9

TEL: (416) 415-5000 FAX: (416) 415 4488

www.georgebrown.ca

APPROVED BY DRAWN

SCALEDWG NAMEPROJECT ADDRESS

CLIENT PROJECT

PLOT DATE

DATE PROJECT NO

DWG NO

REV NOTE

DATE DESCRIPTION

SIGN

DAT 1/8" = 1'-0"

10/23/20172:57:10 PM

PROPOSED HR RENOVATIONHUMAN RESOURCE

105

HUMANRESOURCE

Author10/04/17 2017-044

RCP500 MACPHERSON

1/8" = 1'-0"1

NEW RCP

Page 7: GENERAL NOTES - M.J. Dixon Construction Limited€¦ · stc rating: 35 1" = 1'-0" 1 mtl. stud wall to u/s deck 1" = 1'-0" 2 mtl. stud wall to u/s of ceiling 1" = 1'-0" 3 glazed shopfront

SHRC OFFICE

101-H

SHRC OFFICE

101-G

SHRC OFFICE

101-J

OFFICE

101-F

LUNCH

106

2

106

3/8" CLEAR TEMPERED GLASS

SILICONE JOINT

PIVOT GLASS DOOR

NEW GYP. BD CEILING ON METAL STUDS AT 8'AFF

INSTALL NEW ELECTRICAL FIXTURE -SEE SPEC (TYP)

NEW INSULATED DRYWALL ON 3 5/8 STUDS @16"OC WITH 3/4" GYPSUM BOARD ON EITHER SIDE TO U/S OF DECK

NEW INSULATED DRYWALL ON 3 5/8 STUDS @16"OC WITH 3/4" GYPSUM BOARD ON EITHER SIDE TO U/S OF DECK

2- PIECE SINGLE GLAZED NATURAL ANODIZED AL CHANNEL.

2- PIECE SINGLE GLAZED NATURAL ANODIZED AL CHANNEL.

8' -

0"

1' -

0 1

/4"

3' -

11 1

/2"

3' -

0 1

/4"

1

106

FILE

101-A

?

?

8' -

0"

NEW ACT CEILING @8'AFF

PIVOT GLASS DOOR

3/8" CLEAR TEMPERED GLASS

2- PIECE SINGLE GLAZED NATURAL ANODIZED AL CHANNEL.

2- PIECE SINGLE GLAZED NATURAL ANODIZED AL CHANNEL.

48" EXTRUDED PULL/PUSH BAR

OFFICE

101-P

8'-0

"

NEW ACT CEILING @8'AFF

3/8" CLEAR TEMPERED GLASS

PIVOT GLASS DOOR

48" EXTRUDED PULL/PUSH BAR

GEORGE BROWN COLLEGE

200 KING STREET EAST,

FACILITIES MANAGEMENT ROOM 209B

TORONTO ONTARIO M5T 2T9

TEL: (416) 415-5000 FAX: (416) 415 4488

www.georgebrown.ca

APPROVED BY DRAWN

SCALEDWG NAMEPROJECT ADDRESS

CLIENT PROJECT

PLOT DATE

DATE PROJECT NO

DWG NO

REV NOTE

DATE DESCRIPTION

SIGN

DAT

3/16" =1'-0"

10/23/20172:57:10 PM

PROPOSED HR RENOVATIONHUMAN RESOURCE

106

HUMANRESOURCE

Benjamin09/27/17 2017-044

GLAZED PARTITIONS500 MACPHERSON

3/16" = 1'-0"1

Section 1

3/16" = 1'-0"2

Section 2 3/16" = 1'-0"

3ENTRANCE DOOR ELEVATION

Page 8: GENERAL NOTES - M.J. Dixon Construction Limited€¦ · stc rating: 35 1" = 1'-0" 1 mtl. stud wall to u/s deck 1" = 1'-0" 2 mtl. stud wall to u/s of ceiling 1" = 1'-0" 3 glazed shopfront

DOOR TYPE 1 DOOR TYPE 3

FRAMELESS 3/8" CLEAR TEMPERED GLASS DOOR

0' - 6" 0' - 6"

2' - 1

0"0'

- 6"

HOLLOW METAL W/ LITE

1/4" CLEAR TEMP. GLASS @ INTERIOR DOORST

SARGENT 10G37-LL-US26D 10 LINE HEAVY-DUTY CYLINDRICAL LEVER LOCK OFFICE FUNCTION 626 EXCEPT FILING ROOM DOOR WHICH IS STORAGE FUNCTION.

ALL LOCKSETS TO BE SATIN CHROME

T

3' - 0"

7' -

0"

3' - 0"

8' -

0"

T

DENOTES TEMPERED GLASS

0' - 6" 0' - 6"0' - 6" 0' - 6"

2' - 1

0"0'

- 6"

T

6' - 0"

7' -

0"

DOUBLE HOLLOW METAL W/ LITES

DOOR TYPE 2

0' - 2"3' - 0" 0' - 2"

7' -

0"

0' -

2"

HM1

0' - 2"6' - 0" 0' - 2"

7' -

0"

0' -

2"

HM2

HOLLOW METAL FRAME HOLLOW METAL FRAME

DOOR TYPE 4

0' - 6" 1' - 0"0' - 6"0' - 6"1' - 0" 0' - 6"

T

4' - 0"

7' -

0"

DOUBLE WOOD DOOR W/ LITES

GEORGE BROWN COLLEGE

200 KING STREET EAST,

FACILITIES MANAGEMENT ROOM 209B

TORONTO ONTARIO M5T 2T9

TEL: (416) 415-5000 FAX: (416) 415 4488

www.georgebrown.ca

APPROVED BY DRAWN

SCALEDWG NAMEPROJECT ADDRESS

CLIENT PROJECT

PLOT DATE

DATE PROJECT NO

DWG NO

REV NOTE

DATE DESCRIPTION

SIGN

DAT 1/4" = 1'-0"

10/23/20172:57:10 PM

PROPOSED HR RENOVATIONHUMAN RESOURCE

107

HUMANRESOURCE

Author10/04/17 2017-044

DOORS AND DOOR SCHEDULE500 MACPHERSON

1/4" = 1'-0"1

DOOR TYPES & FRAMES

DOOR # FROM INTO DOOR TYPE

DOOR WIDTH

DOOR HEIGHT

DOOR MATERIAL

DOOR FINISH

FRAME TYPE

FRAME MATERIAL

FRAME FINISH

GLAZING FIRE RATING

DOOR FUNCTION

DOOR LOCK COMMENTS

STR/CASE

DOOR SCHEDULE

101101 2 3'-0" 8'-0" 3/8"TEMP GLASS N/A N/A N/A CLASSROOMN/A LOCKING LEVER HANDLE

CORR 101-A101A 1 3'-0" 7'-0" HOLLOW METAL 1 HM PAINT STOREROOMN/A CYLINDER TO RECEIVE SCHAGE INTERCHABLE CORE

CORR 101-B101B 1 3'-0" 7'-0" 1 HM OFFICEN/A

CORR 101-C101C 2 3'-0" 7'-0" N/A

CORR CORR101F 3 6'-0" 7'-0" CLASSROOMN/A

101-B 101-C101B-2 4 4'-0" 7'-0" WOOD(POCKET) N/A N/A OFFICEN/A N/A N/A

CORR 101-G101G 2 3'-0" 8'-0" N/A N/A N/A

101-H101H 2 3'-0" 8'-0" N/A N/A N/A

HOLLOW METAL

DOOR FRAME

TO RECEIVE SCHAGE INTERCHABLE CORE

PAINT TEMP GLASS

NO LITE

TEMP GLASS

PAINT

PAINT

PAINT

PAINT

CYLINDER TO RECEIVE SCHAGE INTERCHABLE CORE

TEMP GLASSHOLLOW METAL

3/8"TEMP GLASS CLASSROOMN/A TO RECEIVE SCHAGE INTERCHABLE CORE

3/8"TEMP GLASS N/A N/A N/A N/A TO RECEIVE SCHAGE INTERCHABLE CORE

3/8"TEMP GLASS N/A N/A N/A N/A TO RECEIVE SCHAGE INTERCHABLE CORE

3/8"TEMP GLASS N/A N/A N/A N/A TO RECEIVE SCHAGE INTERCHABLE CORE

3/8"TEMP GLASS N/A N/A N/A N/A TO RECEIVE SCHAGE INTERCHABLE CORE

GLAZED

GLAZED

GLAZED

GLAZED

GLAZED

GLAZED

CORR 101-J101J 2 3'-0" 8'-0"

CORR 101-L101L 2 3'-0" 8'-0"

CORR

3/8"TEMP GLASS N/A N/A N/A N/A TO RECEIVE SCHAGE INTERCHABLE COREGLAZEDCORR 101-M101M 2 3'-0" 8'-0"

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

LOCKING LEVER HANDLE

LOCKING LEVER HANDLE

LOCKING LEVER HANDLE

LOCKING LEVER HANDLE

LOCKING LEVER HANDLE

CYLINDER

CYLINDER TO RECEIVE SCHAGE INTERCHABLE COREOFFICE

TEMP GLASS

TEMP GLASS

TEMP GLASS

TEMP GLASS

TEMP GLASS

TEMP GLASS

TEMP GLASS

PAINT

PAINT

N/A

1

2

HM

HM

Page 9: GENERAL NOTES - M.J. Dixon Construction Limited€¦ · stc rating: 35 1" = 1'-0" 1 mtl. stud wall to u/s deck 1" = 1'-0" 2 mtl. stud wall to u/s of ceiling 1" = 1'-0" 3 glazed shopfront

STAIR 2

STAIR 1

105

2

OFFICE

114

?

STAFF LOUNGE

HUMAN RESOURCES

119

MECH

ROOM

STAIR 5EXEC.DIR. - HR

ENTRANCE

C

TRAINING

FMALE

WR

OFFICE

OFFICE

FILING

OFFICE

OPEN

OFFICE

OFFICE

B

B

STAIR 2

STAIR 1

EXIT 3

A

105

C

115

D

B

112

MALE

WR

Tectonic Cop

yright 2007

48

30

30

C C

30C

T ectonic Cop yright 2007

48

30

30C

C

30

C

30

C

48

30 36

24

CCC

30

C

48

3036

24

CC C

48

30 36

24

CCC

48

3036

24

CC C

48

30

36

24C C

C

48

30 36

24

CCC

48

3036

24

CC C

48

3036

24

CC C

48

C

30

C

30

C

48

30

36

24C C

C

3030

30

30

3030 303030

3030

30

30

30

30

30

-

OFFICE

101-F

OFFICE

101-E

OFFICE

101-D

OFFICE

101-C

OFFICE

101-B

FILE

101-A

OPEN OFFICE

101

SHRC OFFICE

101-G

SHRC OFFICE

101-H

SHRC OFFICE

101-J

MECH

119

LUNCH

106SHRC OFFICE

101-K

LRM OFFICE

101-L H&S OFFICE

101-M

RECEPTION

101

OFFICE

101-P

OFFICE

101-Q

OFFICE

101-R

TRAINING

ROOM

101-N

?

?

NEW ACT CEILING @8'AFF

ALL BRANCHES AND FLEX DUCTS CONNECTIONS TO MATCH NECK SIZE OF SUPPLY AIR DIFFUSER

CLEAN AND REUSE EXISTING SUPPLY GRILLS

EXISTING SUPPLY DUCT

CLEAN AND REUSE EXISTING SUPPLY GRILLS

EXISTING SUPPLY DUCT

TO RTU

TO AC3

EXISTING SUPPLY DUCT

EXISTING SUPPLY DUCT

-

TO RTU

TO AC3

AREA SERVED BY RTU

AREA SERVED BY AC3

GEORGE BROWN COLLEGE

200 KING STREET EAST,

FACILITIES MANAGEMENT ROOM 209B

TORONTO ONTARIO M5T 2T9

TEL: (416) 415-5000 FAX: (416) 415 4488

www.georgebrown.ca

APPROVED BY DRAWN

SCALEDWG NAMEPROJECT ADDRESS

CLIENT PROJECT

PLOT DATE

DATE PROJECT NO

DWG NO

REV NOTE

DATE DESCRIPTION

SIGN

DATAs indicated

10/23/20172:57:11 PM

PROPOSED HR RENOVATIONHUMAN RESOURCE

108

HUMANRESOURCE

Author10/11/17 2017-044

HVAC AND AREAS SERVED BY RTU AND AC3 UNITS500 MACPHERSON

1" = 10'-0"1

HVAC 1" = 20'-0"

2EXISTING HVAC

Page 10: GENERAL NOTES - M.J. Dixon Construction Limited€¦ · stc rating: 35 1" = 1'-0" 1 mtl. stud wall to u/s deck 1" = 1'-0" 2 mtl. stud wall to u/s of ceiling 1" = 1'-0" 3 glazed shopfront

UP

UP

OFFICE

114

?

B

B

STAIR 2

STAIR 1

A

105

C

115

D

B

112

MALE

WR

48

30

30

C C

30C

48

30

30C

C

30

C

30

C

48

30 36

24

CCC

30

C

48

3036

24

CC C

48

30 36

24

CCC

48

3036

24

CC C

48

30

36

24

C

48

30 36

24

CCC

48

3036

24

CC C

48

3036

24

CC C

48

C

30

C

30

C

48

30

36

24C C

C

3030

30

30

3030 303030

3030

30

30

30

30

30

TD

TD

TD

TD

TD

TD

TD

TD TD

TD

TD TD

2

TD TD

TD

TD

TD

TDTD

TD

TD

TD TD

TD

TD

TD TD

TD

TD

TD

TD

FEMALE

WASHROOM

?

149 SF

MALE

WASHROOM

?

131 SF

PUBLIC

CORRIDOR

?STAIR

13

136 SF

MECH

119

129 SF

OFFICE

101-P

189 SF

OFFICE

101-R

127 SF

SHRC OFFICE

101-G

107 SF

FILE

101-A

171 SF

OFFICE

101-E

159 SF

OFFICE

101-B

123 SF

?

??

?P

OFFICE

101-F

202 SF

OFFICE

110-A

274 SF

OFFICE

110-C

170 SF

INTERVIEW

ROOM

114

117 SF

OPEN OFFICE

110

998 SF

WC

109

44 SFOFFICE

110-E

131 SF

LUNCH

106

428 SF

PUBLIC

CORRIDOR

?

OFFICE

101-Q

121 SF

FILLING

110-G

156 SF

TRAINING

ROOM

101-N

400 SF

H&S OFFICE

101-M

86 SF

LRM OFFICE

101-L

107 SF

SHRC OFFICE

101-K

106 SF

SHRC OFFICE

101-J

106 SF

RECEPTION

101

360 SF

BOARDROOM

115

368 SF

OFFICE

101-C

312 SF

OFFICE

101-D

157 SF

SHRC OFFICE

101-H

107 SF

OPEN OFFICE

101

196 SF

Room

V106

0 SF

ELEVATOR

V107

64 SF

STAIR

V108

115 SF

STAIR

V116

205 SF

PRINTER

AREA

C-101P

102 SF

NEW LOW PROFILE WIREMOULDLEGRAND OFRC-8 COMPLETE WITHFLOOR MONUMENT FOR 2 DUPLEXESAND 2 DATA OUTLETS

NEW DATA DROP (TYP)

INSTALL NEW 2 WAY SWITCH @ 50"AFF

EXISTING ELECTRIC PANEL TO REMAIN

INSTALL NEW SWITCH -SEE SPEC @ 50"AFF (TYP)

-EXISTING DATA TO REMAIN - CHECK IF ACTIVE. (TYP)

EXISTING DUPLEX TO REMAIN (TYP)

INSTALL NEW SWITCH -SEE SPEC @ 50"AFF (TYP)

DATA CABLES TO BE CAT 6A.

ALL CONNECTED TO 2ND FLOOR LAN ROOM.

GEORGE BROWN COLLEGE

200 KING STREET EAST,

FACILITIES MANAGEMENT ROOM 209B

TORONTO ONTARIO M5T 2T9

TEL: (416) 415-5000 FAX: (416) 415 4488

www.georgebrown.ca

APPROVED BY DRAWN

SCALEDWG NAMEPROJECT ADDRESS

CLIENT PROJECT

PLOT DATE

DATE PROJECT NO

DWG NO

REV NOTE

DATE DESCRIPTION

SIGN

DAT 1" = 10'-0"

10/23/20172:57:11 PM

PROPOSED HR RENOVATIONHUMAN RESOURCE

109

HUMANRESOURCE

Author10/04/17 2017-044

ELECTRICAL & DATA500 MACPHERSON

1" = 10'-0"2

NEW WORK-Electrical & Data