general notes line types - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device...

27
TVSS J H ELECTRICAL COVER SHEET E-001 ELECTRICAL SITE PLAN - EXISTING & DEMOLITION ED002 POWER PLAN - EXISTING & DEMOLITION ED201 SINGLE LINE DIAGRAM - EXISTING & DEMOLITION ED501 ELECTRICAL SITE PLAN - TEMPORARY ET002 POWER PLAN - TEMPORARY ET201 SINGLE LINE DIAGRAM - TEMPORARY ET501 ELECTRICAL SITE PLAN - NEW WORK E-002 LIGHTING PLAN - NEW WORK E-101 POWER PLAN - NEW WORK E-201 GROUNDING PLAN - NEW WORK E-301 SINGLE LINE DIAGRAM - NEW WORK E-501 SWITCHGEAR ELEVATION - NEW WORK E-601 ELECTRICAL SCHEDULES E-602 E-603 E-605 SWITCHGEAR ELEVATION - EXISTING & DEMOLITION ED601 MANHOLE PLAN - EXISTING & DEMOLITION ED602 MANHOLE FOLDOUTS - EXISTING & DEMOLITION ED603 MANHOLE FOLDOUTS - EXISTING & DEMOLITION ED604 MANHOLE FOLDOUTS - NEW WORK E-604 E-606 MANHOLE FOLDOUTS - NEW WORK MANHOLE PLAN - NEW WORK SCADA PLAN - NEW WORK ELECTRICAL DETAILS E-701 # 52 GENERAL NOTES ELECTRICAL SYMBOLS ABBREVIATIONS LINE TYPES A A A A 3 ANSI/IEEE STANDARD DEVICE NUMBERS LED, STRIP LIGHT, LETTER INDICATES TYPE. LIGHTING FIXTURE, LETTER INDICATES TYPE. LED LIGHTING FIXTURES ON EMERGENCY CIRCUIT, LETTER INDICATES TYPE. 20A, 120/277V THREE-WAY LIGHTING SWITCH MOUNTED +48" ABOVE FINISHED FLOOR (UNLESS OTHERWISE NOTED) EXISTING FEEDER TO REMAIN EXISTING FEEDER TO BE DEMOLISHED NEW FEEDER EXISTING EQUIPMENT/MATERIAL TO REMAIN EXISTING EQUIPMENT/MATERIAL TO BE MOVED/RELOCATED EXISTING EQUIPMENT/MATERIAL TO DEMOLISHED NEW OR RELOCATED EQUIPMENT/MATERIAL JUNCTION BOX RECTIFIER TRANSIENT VOLTAGE SURGE SUPPRESSION FOR CONTINUATION... BATTERY AUTOMATIC TRANSFER SWITCH FUSED DISCONNECT SWITCH DISCONNECT SWITCH CURRENT TRANSFORMER POTENTIAL TRANSFORMER FUSE GROUND METER TRANSFORMER MEDIUM VOLTAGE DRAWOUT CIRCUIT BREAKER DRAWOUT CIRCUIT BREAKER FIX MOUNTED CIRCUIT BREAKER SPACE FOR FIX MOUNTED CIRCUIT BREAKER SPACE FOR DRAWOUT CIRCUIT BREAKER POWER QUALITY METER KVAR KILOVOLT AMPERES REACTIVE KW KILOWATT LRA LOCKED ROTOR AMPERES LTG LIGHTING MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MH METAL HALIDE MIN MINIMUM MLO MAIN LUG ONLY MOP METHOD OF PROCEDURE MTD MOUNTED N.C. NORMALLY CLOSED NEC NATIONAL ELECTRICAL CODE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NETA NATIONAL ELECTRICAL TESTING AGENCY N.F.S. NON-FUSED SAFETY SWITCH NIC NOT IN CONTRACT N.T.S. NOT TO SCALE P POLES PAF ARC-FLASH OVERCURRENT RELAY P/T POTENTIAL TRANSFORMER PF POWER FACTOR PNL PANEL, PANELBOARD PQM POWER QUALITY METER Ø PHASE RECEPT, RECEPTACLE RECP RLA RUNNING LOAD AMPERES S, SW SWITCH SWBD SWITCHBOARD S/N SOLID NEUTRAL SWGR SWITCHGEAR TEL TELEPHONE THRU THROUGH TYP TYPICAL UL UNDERWRITERS LABORATORY, INC. UPS UNINTERRUPTIBLE POWER SUPPLY U.O.N. UNLESS OTHERWISE NOTED V VOLT VA VOLTAMPERES VAR VOLTAMPERES REACTIVE V/T VOLTAGE TRANSFORMER W WATT WP WEATHER PROOF A, AMP AMPERE A/C AIR CONDITIONING AC ALTERNATING CURRENT ADA AMERICANS WITH DISABILITIES ACT AFF ABOVE FINISHED FLOOR AHU AIR HANDLING UNIT A.I.C. AMPERES INTERRUPTING CAPACITY AUX COMP. AUXILIARY COMPARTMENT ATS AUTOMATIC TRANSFER SWITCH BRK BREAKER CB CIRCUIT BREAKER C/T CURRENT TRANSFORMER C. CND CONDUIT CKT CIRCUIT COMM COMMUNICATIONS CR CARD READER CU COPPER DPR DIFFERENTIAL PROTECTIVE RELAY DWG DRAWING ELEV ELEVATOR EW EMERGENCY WHITE LIGHT EWC ELECTRIC WATER COOLER FAAP FIRE ALARM ANNUNCIATOR PANEL FACP FIRE ALARM CONTROL PANEL FC FOOTCANDLE FLA FULL LOAD AMPERES FLUOR FLUORESCENT FM FACTORY MUTUAL FMR FEEDER MANAGEMENT RELAY F.S.S. FUSED SAFETY SWITCH GFCI GROUND FAULT CURRENT INTERRUPTER GRD, G GROUND HID HIGH INTENSITY DISCHARGE HP HORSEPOWER HOR HORIZONTAL HPS HIGH PRESSURE SODIUM HTR HEATER HZ HERTZ INCAND INCANDESCENT JB JUNCTION BOX K.A.I.C. 1000 AMPERES INTERRUPTING CAPACITY KCMIL 1000 CIRCULAR MILS KV KILOVOLT KVA KILOVOLT AMPERES 51G GROUND TIME OVERCURRENT RELAY 52 AC CIRCUIT BREAKER 59 OVERVOLTAGE RELAY 67 AC DIRECTIONAL OVERCURRENT RELAY 81 FREQUENCY RELAY 86 LOCKOUT RELAY 87 DIFFERENTIAL PROTECTIVE RELAY 25 SYNCHRONISM CHECK DEVICE 27 UNDERVOLTAGE RELAY 32 DIRECTIONAL POWER RELAY 50 PHASE INSTANTANEOUS OVERCURRENT RELAY 50G GROUND INSTANTANEOUS OVERCURRENT RELAY 51 PHASE TIME OVERCURRENT RELAY AFD ARC-FLASH DETECTOR ELECTRICAL DRAWING LIST M PQM GROUND ROD S X EMPTY DUCT FILLED DUCT STRUNG DUCT BLOCKED DUCT G 3 GLOWTUBE. SUBSCRIPT DENOTES NUMBER OF TUBES. JUNCTION BAR ELECTRIC HEATER CONNECTION. MOTOR CONNECTION K.3. ALL WORK SHALL BE EXECUTED IN A WORKMANLIKE MANNER AND SHALL PRESENT A NEAT AND CLEAN APPEARANCE WHEN COMPLETED. COVERS SHALL BE INSTALLED AND TIGHTLY FASTENED ON ALL ELECTRICAL ENCLOSURES. THE ENCLOSURES SHALL BE FREE OF DEBRIS AND LOOSE HARDWARE ON THE INTERIOR AND EXTERIOR. ALL ENCLOSURES SHALL BE CLEARLY IDENTIFIED ON THE EXTERIOR WITH PROPER NOMENCLATURE AND EXPECTED ARC FLASH LEVELS. L. TESTING L.1. AT THE TIME OF FINAL INSPECTION AND TEST, ALL CONNECTIONS AT PANELBOARDS, DEVICES AND EQUIPMENT, AND ALL SPLICES MUST BE COMPLETED. EACH CIRCUIT AND ITS RESPECTIVE CONNECTED EQUIPMENT MUST TEST FREE OF SHORT CIRCUITS AND GROUNDS. L.2. PROVIDE TESTING OF ALL ELECTRICAL COMPONENTS PER NETA TEST PROCEDURES INCLUDING ALL THE OPTIONAL TESTING PROCEDURES. M. SHOP DRAWINGS P.1. SUBMIT SHOP DRAWINGS; ELECTRONIC FORMAT (PDF), OF ELECTRICAL EQUIPMENT TO ENGINEER FOR REVIEW AND APPROVAL BEFORE ORDERING. R. FIRE ALARM WORK R.1. EXISTING FIRE ALARM IS TO REMAIN. R.2. CONTRACTOR SHALL MAINTAIN THE CONTINUITY OF ALL EXISTING FIRE ALARM SYSTEM DEVICES AND KEEP THEM OPERATIONAL DURING ALL STAGES OF THIS CONTRACT. A. THE INSTALLATION SHALL COMPLY WITH ALL LOCAL LAWS AND ORDINANCES, APPLICABLE TO ELECTRICAL INSTALLATIONS, AND WITH THE REGULATIONS OF NFPA 70 (NATIONAL ELECTRICAL CODE) AND 70E (STANDARD FOR ELECTRICAL SAFETY IN THE WORKPLACE) WHERE SUCH REGULATIONS DO NOT CONFLICT WITH THOSE LAWS. SUBCONTRACTOR SHALL OBTAIN ALL PERMITS AND COORDINATE ALL INSPECTIONS REQUIRED BY THE AUTHORITY HAVING JURISDICTION (AHJ). B. ELECTRICAL CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS REQUIRED FOR THIS WORK. C. ALL MATERIALS, EQUIPMENT AND APPARATUS COVERED BY THIS SPECIFICATION SHALL BE NEW, OF CURRENT MANUFACTURER AND SHALL BEAR THE SEAL OF APPROVAL OF THE UNDERWRITERS' LABORATORIES (UL LISTED). NEW EQUIPMENT SHALL BE CLEARLY LABELED WITH THE MANUFACTURER'S NAMEPLATE DATA. D. ALL EQUIPMENT TO BE PROVIDED BY THE CONTRACTOR SHALL BE AS MANUFACTURED BY GENERAL ELECTRIC, SQUARE-D COMPANY, SIEMENS AND/OR CUTLER HAMER. (WESTINGHOUSE.) E. ALL ELECTRICAL EQUIPMENT SHALL BE NEW. F. "PROVIDE" UNDER THIS CONTRACT IS DEFINED AS FURNISH AND INSTALL. "CONCEALED" UNDER THIS CONTRACT IS DEFINED AS HIDDEN BY ARCHITECTURAL WALLS AND CEILINGS. "EXPOSED" UNDER THIS CONTRACT IS DEFINED AS VISIBLE TO VIEW. "INDICATED" UNDER THIS CONTRACT IS DEFINED AS SHOWN IN THE CONTRACT DOCUMENTS. G. ALL ELECTRICAL PANELS, AND ALL MAJOR PIECES OF EQUIPMENT SHALL BE CLEARLY LABELED WITH MINIMUM 25.4 MM [1"] HIGH LETTERS. PROVIDE A TYPED CIRCUIT DIRECTORY FOR EACH PANELBOARD INSTALLED UNDER THIS CONTRACT. EXISTING PANELBOARDS BEING REVISED SHALL HAVE DIRECTORY CORRECTED TO REFLECT TO NEW CONDITION. H. THE SUBCONTRACTOR SHALL LEAVE THE ENTIRE ELECTRICAL SYSTEM INSTALLED UNDER THIS CONTRACT IN PROPER WORKING ORDER AND SHALL REPLACE, WITHOUT ADDITIONAL CHARGE, ALL WORK OR MATERIAL WHICH MAY DEVELOP DEFECTS, ORDINARY WEAR AND TEAR OR DAMAGE RESULTING FROM IMPROPER HANDLING EXCEPTED, WITHIN A PERIOD OF ONE YEAR FORM THE DATE OF INITIAL TESTING AND ACCEPTANCE BY THE CONTRACTOR. I. COORDINATION I.1. ALL CONTROL WIRING LESS THAT 120V FOR HVAC EQUIPMENT SHALL BE FURNISHED AND INSTALLED BY DIVISION 23. I.2. ALL CONTROL WIRING 120V AND ABOVE FOR HVAC EQUIPMENT SHALL BE FURNISHED AND INSTALLED BY DIVISION 26. J. EXISTING CONDITIONS AND DEMOLITION WORK J.1. THIS CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH ALL THE EXISTING CONDITIONS THAT MAY AFFECT HIS WORK. J.2. THIS CONTRACTOR SHALL COORDINATE WITH ARCHITECTURAL DEMOLITION PLANS FOR ALL DEMOLITION WORK. REMOVE, PACKAGE AND STORE ALL EXISTING ELECTRICAL EQUIPMENT NOTED TO BE RE-USED, REFURBISH ALL OF THIS EQUIPMENT PRIOR TO INSTALLATION PER NEW WORK. J.3. THIS CONTRACTOR SHALL MAINTAIN THE CONTINUITY OF ALL EXISTING ELECTRICAL WORK AFFECTED BY THIS CONTRACT. RESTORE CIRCUITS SERVING EXISTING EQUIPMENT TO REMAIN WHICH ARE INTERRUPTED DURING THE COURSE OF THIS WORK. ANY REQUIRED ELECTRICAL OUTAGE SHALL BE AFTER REGULAR HOURS AND REQUESTED IN WRITING FOR APPROVAL BY THE BUILDING OWNER/REPRESENTATIVE. J.4. CONTRACTOR SHALL REFER TO THE CONTRACT DOCUMENTS FOR EXTENT OF DEMOLITION WORK. K. MISCELLANEOUS N.1. ALL EMPTY RACEWAY SHALL CONTAIN A PULL WIRE. K.2. WORK AREA SHALL BE CLEAN OF DEBRIS AFTER COMPLETION OF WORK. IGIN INTELLIGENT GRID INTERFACE NODE Last Plotted: Filename: 1 2 3 4 5 A B C D 5 4 3 2 1 OFFICE OF RESEARCH FACILITIES PROJECT TITLE DRAWING TITLE MARK DATE DESCRIPTION REVISIONS SEAL CONTRACTORS BUILDING PROJECT DRAWING A/E Name and LOGO A/E CON. NO. A/E TASK NO. CONS. CONTR. CONS. WORK PRIME A/E SUB A/E CONSTR. CON. FACILITY CODE BUILDING NO. NAME STREET CITY STATE/ZIP OTHER BUILDING NO. PROJ. NO. PROJ. OFFICER PROJ. MGR. SUBMISSION SUB. DATE WRK REQ. NO. Bethesda NIH Campus 9000 Rockville Pike Bethesda MD, 20892 ISSUE FOR CONSTRUCTION 11/03/2017 DESIGNED BY DRAWN BY CHECKED BY FILE NAME DRAWING NO. SHEET OF 47 AECOM UPGRADE ELECTRICAL SUBSTATION HHSN292201400001I HHSN29200011 EDG-2 17 17 DT JL C102846 11/2/2017 4:01:17 PM C:\Users\michael.kline.EDG2\Documents\Revit 2015\16018E-R2015_michael.kline.rvt E-001 MK MK GC Project Number ELECTRICAL COVER SHEET 21

Upload: others

Post on 27-Oct-2019

11 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

TVSS

J

H

ELECTRICAL COVER SHEETE-001

ELECTRICAL SITE PLAN - EXISTING & DEMOLITIONED002

POWER PLAN - EXISTING & DEMOLITIONED201

SINGLE LINE DIAGRAM - EXISTING & DEMOLITIONED501

ELECTRICAL SITE PLAN - TEMPORARYET002

POWER PLAN - TEMPORARYET201

SINGLE LINE DIAGRAM - TEMPORARYET501

ELECTRICAL SITE PLAN - NEW WORKE-002

LIGHTING PLAN - NEW WORKE-101

POWER PLAN - NEW WORKE-201

GROUNDING PLAN - NEW WORKE-301

SINGLE LINE DIAGRAM - NEW WORKE-501

SWITCHGEAR ELEVATION - NEW WORKE-601

ELECTRICAL SCHEDULESE-602

E-603

E-605

SWITCHGEAR ELEVATION - EXISTING & DEMOLITIONED601

MANHOLE PLAN - EXISTING & DEMOLITIONED602

MANHOLE FOLDOUTS - EXISTING & DEMOLITIONED603

MANHOLE FOLDOUTS - EXISTING & DEMOLITIONED604

MANHOLE FOLDOUTS - NEW WORKE-604

E-606

MANHOLE FOLDOUTS - NEW WORK

MANHOLE PLAN - NEW WORK

SCADA PLAN - NEW WORK

ELECTRICAL DETAILSE-701

#52

GENERAL NOTES

ELECTRICAL SYMBOLS

ABBREVIATIONS

LINE TYPES

A

A

AA

3

ANSI/IEEE STANDARD DEVICE NUMBERS

LED, STRIP LIGHT, LETTER INDICATES TYPE.

LIGHTING FIXTURE, LETTER INDICATES TYPE.

LED LIGHTING FIXTURES ON EMERGENCY CIRCUIT, LETTER INDICATES TYPE.

20A, 120/277V THREE-WAY LIGHTING SWITCH MOUNTED +48" ABOVE FINISHED FLOOR (UNLESS

OTHERWISE NOTED)

EXISTING FEEDER TO REMAIN

EXISTING FEEDER TO BE DEMOLISHED

NEW FEEDER

EXISTING EQUIPMENT/MATERIAL TO REMAIN

EXISTING EQUIPMENT/MATERIAL TO BE MOVED/RELOCATED

EXISTING EQUIPMENT/MATERIAL TO DEMOLISHED

NEW OR RELOCATED EQUIPMENT/MATERIAL

JUNCTION BOX

RECTIFIER

TRANSIENT VOLTAGE SURGE SUPPRESSION

FOR CONTINUATION...

BATTERY

AUTOMATIC TRANSFER SWITCH

FUSED DISCONNECT SWITCH

DISCONNECT SWITCH

CURRENT TRANSFORMER

POTENTIAL TRANSFORMER

FUSE

GROUND

METER

TRANSFORMER

MEDIUM VOLTAGE DRAWOUT CIRCUIT BREAKER

DRAWOUT CIRCUIT BREAKER

FIX MOUNTED CIRCUIT BREAKER

SPACE FOR FIX MOUNTED CIRCUIT BREAKER

SPACE FOR DRAWOUT CIRCUIT BREAKER

POWER QUALITY METER

KVAR KILOVOLT AMPERES REACTIVE

KW KILOWATT

LRA LOCKED ROTOR AMPERES

LTG LIGHTING

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MH METAL HALIDE

MIN MINIMUM

MLO MAIN LUG ONLY

MOP METHOD OF PROCEDURE

MTD MOUNTED

N.C. NORMALLY CLOSED

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION

NETA NATIONAL ELECTRICAL TESTING AGENCY

N.F.S. NON-FUSED SAFETY SWITCH

NIC NOT IN CONTRACT

N.T.S. NOT TO SCALE

P POLES

PAF ARC-FLASH OVERCURRENT RELAY

P/T POTENTIAL TRANSFORMER

PF POWER FACTOR

PNL PANEL, PANELBOARD

PQM POWER QUALITY METER

Ø PHASE

RECEPT, RECEPTACLERECP

RLA RUNNING LOAD AMPERES

S, SW SWITCH

SWBD SWITCHBOARD

S/N SOLID NEUTRAL

SWGR SWITCHGEAR

TEL TELEPHONE

THRU THROUGH

TYP TYPICAL

UL UNDERWRITERS LABORATORY, INC.

UPS UNINTERRUPTIBLE POWER SUPPLY

U.O.N. UNLESS OTHERWISE NOTED

V VOLT

VA VOLTAMPERES

VAR VOLTAMPERES REACTIVE

V/T VOLTAGE TRANSFORMER

W WATT

WP WEATHER PROOF

A, AMP AMPERE

A/C AIR CONDITIONING

AC ALTERNATING CURRENT

ADA AMERICANS WITH DISABILITIES ACT

AFF ABOVE FINISHED FLOOR

AHU AIR HANDLING UNIT

A.I.C. AMPERES INTERRUPTING CAPACITY

AUX COMP. AUXILIARY COMPARTMENT

ATS AUTOMATIC TRANSFER SWITCH

BRK BREAKER

CB CIRCUIT BREAKER

C/T CURRENT TRANSFORMER

C. CND CONDUIT

CKT CIRCUIT

COMM COMMUNICATIONS

CR CARD READER

CU COPPER

DPR DIFFERENTIAL PROTECTIVE RELAY

DWG DRAWING

ELEV ELEVATOR

EW EMERGENCY WHITE LIGHT

EWC ELECTRIC WATER COOLER

FAAP FIRE ALARM ANNUNCIATOR PANEL

FACP FIRE ALARM CONTROL PANEL

FC FOOTCANDLE

FLA FULL LOAD AMPERES

FLUOR FLUORESCENT

FM FACTORY MUTUAL

FMR FEEDER MANAGEMENT RELAY

F.S.S. FUSED SAFETY SWITCH

GFCI GROUND FAULT CURRENT INTERRUPTER

GRD, G GROUND

HID HIGH INTENSITY DISCHARGE

HP HORSEPOWER

HOR HORIZONTAL

HPS HIGH PRESSURE SODIUM

HTR HEATER

HZ HERTZ

INCAND INCANDESCENT

JB JUNCTION BOX

K.A.I.C. 1000 AMPERES INTERRUPTING CAPACITY

KCMIL 1000 CIRCULAR MILS

KV KILOVOLT

KVA KILOVOLT AMPERES

51G GROUND TIME OVERCURRENT RELAY

52 AC CIRCUIT BREAKER

59 OVERVOLTAGE RELAY

67 AC DIRECTIONAL OVERCURRENT RELAY

81 FREQUENCY RELAY

86 LOCKOUT RELAY

87 DIFFERENTIAL PROTECTIVE RELAY

25 SYNCHRONISM CHECK DEVICE

27 UNDERVOLTAGE RELAY

32 DIRECTIONAL POWER RELAY

50 PHASE INSTANTANEOUS OVERCURRENT RELAY

50G GROUND INSTANTANEOUS OVERCURRENT RELAY

51 PHASE TIME OVERCURRENT RELAY

AFD ARC-FLASH DETECTOR

ELECTRICAL DRAWING LIST

M

PQM

GROUND ROD

S

X

EMPTY DUCT

FILLED DUCT

STRUNG DUCT

BLOCKED DUCT

G3

GLOWTUBE. SUBSCRIPT DENOTES NUMBER OF TUBES.

JUNCTION BAR

ELECTRIC HEATER CONNECTION.

MOTOR CONNECTION

K.3. ALL WORK SHALL BE EXECUTED IN A WORKMANLIKE MANNER AND SHALL PRESENT A NEATAND CLEAN APPEARANCE WHEN COMPLETED. COVERS SHALL BE INSTALLED AND TIGHTLYFASTENED ON ALL ELECTRICAL ENCLOSURES. THE ENCLOSURES SHALL BE FREE OF DEBRISAND LOOSE HARDWARE ON THE INTERIOR AND EXTERIOR. ALL ENCLOSURES SHALL BECLEARLY IDENTIFIED ON THE EXTERIOR WITH PROPER NOMENCLATURE AND EXPECTED ARCFLASH LEVELS.

L. TESTING

L.1. AT THE TIME OF FINAL INSPECTION AND TEST, ALL CONNECTIONS AT PANELBOARDS,DEVICES AND EQUIPMENT, AND ALL SPLICES MUST BE COMPLETED. EACH CIRCUIT AND ITSRESPECTIVE CONNECTED EQUIPMENT MUST TEST FREE OF SHORT CIRCUITS AND GROUNDS.

L.2. PROVIDE TESTING OF ALL ELECTRICAL COMPONENTS PER NETA TEST PROCEDURESINCLUDING ALL THE OPTIONAL TESTING PROCEDURES.

M. SHOP DRAWINGS

P.1. SUBMIT SHOP DRAWINGS; ELECTRONIC FORMAT (PDF), OF ELECTRICAL EQUIPMENT TOENGINEER FOR REVIEW AND APPROVAL BEFORE ORDERING.

R. FIRE ALARM WORK

R.1. EXISTING FIRE ALARM IS TO REMAIN.

R.2. CONTRACTOR SHALL MAINTAIN THE CONTINUITY OF ALL EXISTING FIRE ALARM SYSTEMDEVICES AND KEEP THEM OPERATIONAL DURING ALL STAGES OF THIS CONTRACT.

A. THE INSTALLATION SHALL COMPLY WITH ALL LOCAL LAWS AND ORDINANCES, APPLICABLE TOELECTRICAL INSTALLATIONS, AND WITH THE REGULATIONS OF NFPA 70 (NATIONAL ELECTRICALCODE) AND 70E (STANDARD FOR ELECTRICAL SAFETY IN THE WORKPLACE) WHERE SUCHREGULATIONS DO NOT CONFLICT WITH THOSE LAWS. SUBCONTRACTOR SHALL OBTAIN ALLPERMITS AND COORDINATE ALL INSPECTIONS REQUIRED BY THE AUTHORITY HAVING JURISDICTION(AHJ).

B. ELECTRICAL CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS REQUIRED FOR THIS WORK.

C. ALL MATERIALS, EQUIPMENT AND APPARATUS COVERED BY THIS SPECIFICATION SHALL BE NEW,OF CURRENT MANUFACTURER AND SHALL BEAR THE SEAL OF APPROVAL OF THE UNDERWRITERS'LABORATORIES (UL LISTED). NEW EQUIPMENT SHALL BE CLEARLY LABELED WITH THEMANUFACTURER'S NAMEPLATE DATA.

D. ALL EQUIPMENT TO BE PROVIDED BY THE CONTRACTOR SHALL BE AS MANUFACTURED BYGENERAL ELECTRIC, SQUARE-D COMPANY, SIEMENS AND/OR CUTLER HAMER. (WESTINGHOUSE.)

E. ALL ELECTRICAL EQUIPMENT SHALL BE NEW.

F. "PROVIDE" UNDER THIS CONTRACT IS DEFINED AS FURNISH AND INSTALL. "CONCEALED" UNDERTHIS CONTRACT IS DEFINED AS HIDDEN BY ARCHITECTURAL WALLS AND CEILINGS. "EXPOSED"UNDER THIS CONTRACT IS DEFINED AS VISIBLE TO VIEW. "INDICATED" UNDER THIS CONTRACT ISDEFINED AS SHOWN IN THE CONTRACT DOCUMENTS.

G. ALL ELECTRICAL PANELS, AND ALL MAJOR PIECES OF EQUIPMENT SHALL BE CLEARLY LABELEDWITH MINIMUM 25.4 MM [1"] HIGH LETTERS. PROVIDE A TYPED CIRCUIT DIRECTORY FOR EACHPANELBOARD INSTALLED UNDER THIS CONTRACT. EXISTING PANELBOARDS BEING REVISED SHALLHAVE DIRECTORY CORRECTED TO REFLECT TO NEW CONDITION.

H. THE SUBCONTRACTOR SHALL LEAVE THE ENTIRE ELECTRICAL SYSTEM INSTALLED UNDER THISCONTRACT IN PROPER WORKING ORDER AND SHALL REPLACE, WITHOUT ADDITIONAL CHARGE, ALLWORK OR MATERIAL WHICH MAY DEVELOP DEFECTS, ORDINARY WEAR AND TEAR OR DAMAGERESULTING FROM IMPROPER HANDLING EXCEPTED, WITHIN A PERIOD OF ONE YEAR FORM THEDATE OF INITIAL TESTING AND ACCEPTANCE BY THE CONTRACTOR.

I. COORDINATION

I.1. ALL CONTROL WIRING LESS THAT 120V FOR HVAC EQUIPMENT SHALL BE FURNISHED ANDINSTALLED BY DIVISION 23.

I.2. ALL CONTROL WIRING 120V AND ABOVE FOR HVAC EQUIPMENT SHALL BE FURNISHED ANDINSTALLED BY DIVISION 26.

J. EXISTING CONDITIONS AND DEMOLITION WORK

J.1. THIS CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH ALL THE EXISTINGCONDITIONS THAT MAY AFFECT HIS WORK.

J.2. THIS CONTRACTOR SHALL COORDINATE WITH ARCHITECTURAL DEMOLITION PLANS FOR ALLDEMOLITION WORK. REMOVE, PACKAGE AND STORE ALL EXISTING ELECTRICAL EQUIPMENTNOTED TO BE RE-USED, REFURBISH ALL OF THIS EQUIPMENT PRIOR TO INSTALLATION PER NEWWORK.

J.3. THIS CONTRACTOR SHALL MAINTAIN THE CONTINUITY OF ALL EXISTING ELECTRICAL WORKAFFECTED BY THIS CONTRACT. RESTORE CIRCUITS SERVING EXISTING EQUIPMENT TO REMAINWHICH ARE INTERRUPTED DURING THE COURSE OF THIS WORK. ANY REQUIRED ELECTRICALOUTAGE SHALL BE AFTER REGULAR HOURS AND REQUESTED IN WRITING FOR APPROVAL BY THEBUILDING OWNER/REPRESENTATIVE.

J.4. CONTRACTOR SHALL REFER TO THE CONTRACT DOCUMENTS FOR EXTENT OF DEMOLITION WORK.

K. MISCELLANEOUS

N.1. ALL EMPTY RACEWAY SHALL CONTAIN A PULL WIRE.

K.2. WORK AREA SHALL BE CLEAN OF DEBRIS AFTER COMPLETION OF WORK.

IGIN INTELLIGENT GRID INTERFACE NODE

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

OFFICE OFRESEARCH FACILITIES

PRO

JEC

TTI

TLE

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEAL

CO

NTR

ACTO

RS

BUIL

DIN

GPR

OJE

CT

DR

AWIN

GA/

E N

ame

and

LOG

O

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

11/2

/201

7 4:

01:1

7 PM

C:\U

sers

\mic

hael

.klin

e.ED

G2\

Doc

umen

ts\R

evit

2015

\160

18E-

R20

15_m

icha

el.k

line.

rvt

E-001

MK

MK

GC

Project Number

ELEC

TRIC

AL C

OVE

R S

HEE

T

21

Page 2: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

1ED201

SWGR1

SWGR2

SWGR3

1

1

1

1

2

2

2

2

EN-93

EN-101

EN-100

EN-99

EN-95

EN-114

EN-115

EN-96

PEPCO AREA

PEPCO AREA

EN-94

EN-94

EN-93

EN-101

EN-100

EN-99

T-69

EN-95

EN-114

EN-115EN-96

EN-98

EN-102

EN-92

EN-89

EN-88

EN-90

1. REFER TO DRAWINGS ED602, ED603, AND ED604 FOR MOREINFORMATION.

2. DUCT BANK ROUTING IS DIAGRAMMATIC. CONTRACTOR TOFIELD VERIFY ACUTAL ROUTES.

3. U.O.N. ALL DUCT BANKS ARE EXISTING TO REMAIN.

GENERAL DRAWING NOTES:

DISCONNECT AND REMOVE EXISTING FEEDERS AND DEMOLISHEXISTING DUCT BANK.

DEMOLISH EXISTING EMPTY DUCT BANKS BETWEEN THIS MANHOLEAND MANHOLE EN-95.

SPECIFIC DRAWING NOTES:1

2

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

KEY PLANSCALE: N.T.S.

OFFICE OFRESEARCH FACILITIES

PRO

JEC

TTI

TLE

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEAL

CO

NTR

ACTO

RS

BUIL

DIN

GPR

OJE

CT

DR

AWIN

GA/

E N

ame

and

LOG

O

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

BUILDING 17

BUILDING 21

11/2

/201

7 4:

01:2

9 PM

C:\U

sers

\mic

hael

.klin

e.ED

G2\

Doc

umen

ts\R

evit

2015

\160

18E-

R20

15_m

icha

el.k

line.

rvt

ED002

MK

MK

GC

Project Number

ELEC

TRIC

AL S

ITE

PLAN

- EX

ISTI

NG

&D

EMO

LITI

ON

22

1 : 1252 ELECTRICAL SITE PLAN - EXISTING & DEMOLITION

0 62503125

1:125

N

1 : 5001 ELECTRICAL MANHOLE PLAN - EXISTING

0 2500012500

1:500

0 2500012500

1:500

Page 3: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

SCADA SYSTEMENCLOSURE

BATTERIES

BATTERY CHARGER/RECTIFIER

125V DC SWBD

INTERFACE PANEL(RTU/NIH/TB)

SUPERVISORYPANEL

REVENUEMETERS

PANEL 54SS/UTILITY METER

ATS

VACUUMTESTCUBICLE

MANHOLEEN-94 3

2TYP.

4

4

4

1

5

5

5

6

SWGR 3

SWGR 2

SWGR 1

7

1

2

3

4

5

6

7

A

1. REFER TO DRAWINGS ED002, ED501, ED601, AND ED602 FORMORE INFORMATION.

2. REFER TO FIRE ALARM DRAWINGS FOR MORE INFORMATION.

GENERAL DRAWING NOTES:

DISCONNECT AND REMOVE ALL EXISTING LIGHTING FIXTURES ANDALL ASSOICATED WIRES/CONDUIT BACK TO SOURCE.

DISCONNECT AND REMOVE ALL EXISTING ELECTRICAL EQUIPMENTAND ALL ASSOCIATED WIRING/CONDUIT BACK TO SOURCE.

MANHOLE COVER TO BE RELOCATED. REFER TO STRUCTURALDRAWINGS FOR MORE INFORMATION.

DISCONNECT AND REMOVE EXISTING DUCTS BACK TO MANHOLEEN-93.

DISCONNECT AND REMOVE EXISTING DUCTS BACK TO MANHOLEEN-101.

DISCONNECT AND REMOVE EXISTING DUCTS BACK TO MANHOLEEN-96.

DISCONNECT AND REMOVE EXISTING GROUND BAR.

SPECIFIC DRAWING NOTES:1

2

3

4

5

6

7

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

KEY PLANSCALE: N.T.S.

OFFICE OFRESEARCH FACILITIES

PRO

JEC

TTI

TLE

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEAL

CO

NTR

ACTO

RS

BUIL

DIN

GPR

OJE

CT

DR

AWIN

GA/

E N

ame

and

LOG

O

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

BUILDING 17

BUILDING 21

11/2

/201

7 4:

01:3

0 PM

C:\U

sers

\mic

hael

.klin

e.ED

G2\

Doc

umen

ts\R

evit

2015

\160

18E-

R20

15_m

icha

el.k

line.

rvt

ED201

MK

MK

GC

Project Number

POW

ER P

LAN

- D

EMO

LITI

ON

23

1 : 1001 SWITCHGEAR LEVEL - DEMOLITION

0 50002500

1:100

N

Page 4: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

FDR 1TO BLDGS 2, 3,

4, 5 & 10(VAULTS 12 &

13)

FDR 4TO BLDG 59 &

BLDG 10(VAULTS 1, 2,

3, 4, & 5)

FDR 2TO BLDGS

12A, 12UPPER, 12

LOWER & 50

FDR 6TO BLDG 11

(4,160 V)

FDR 5TO BLDG 57

FDR 3TO BLDG 33 &

MLP-10

FDR 7TO BLDGS 6,

6A, 6B, 8, 13N,14A, 14B, 31A,

31B, & 31C

FDR 15TO BLDG 57

FDR 14TO BLDGS 3, 4,5, 16A, 16B, 21,

21B, & TG9

FDR 16TO BLDG 11

(4,160 V)

FDR 11TO BLDG 59

FDR 13TO BLDGS

12A. 12UPPER, 12

LOWER, 12E,12 GARAGE, &

50

FDR 12TO BLDGS 33

& 67

FDR 17TO BLDGS 6,

6A, 6B, 8, 13S,14A, 14B, 31A,

31B, & 31C

FDR 21TO BLDGS

12A. 12UPPER, 12

LOWER, 12E,12 GARAGE, &

50

FDR 25TO BLDG 57

FDR 19TO BLDG 33 &

UTILITYTUNNEL

FDR 26TO BLDG 11

(4,160 V)

FDR 18TO BLDG 59

FDR 27TO BLDGS 6, 6A,6B, 8, 13S, 13N,14A, 31A, 31B, &

31C

FDR 20TO BLDGS1, 2, 4, 5, 10

(VAULTS 12 &13), & 21

2000A, 3PH, 3W, 13.8KVSWGR 1

1

2

3

54SS PANEL400A, 3PH, 4W, 208Y/120V

200AF200AT

50AF50AT

200AF200AT

DCSWBD

ATS

TOPEPCOAREA

TOPEPCOAREA

4

BATTERYCHARGER

6

7

PEPCO METER

3 3 3 3 3 3 3 3 3 3 3 3 3

3 3 3 3 3 3 3

2 2 2

2 2

NIH1M2000AFN.C.

NIH1T2000AFN.C.

8 8

M

50 51

DPR

87

50G 51G

86

50 51

50G 51G

86

50 51

50G 51G

86

50 51

50G 51G

86

50 51

50G 51G

86

50 51

50G 51G

86

50 51

50G 51G

86

51 51G 51 51G

2000A, 3PH, 3W, 13.8KVSWGR 2

NIH2M2000AFN.C.

NIH2T2000AFN.C.

50 51

DPR

87

50G 51G

86

50 51

50G 51G

86

50 51

50G 51G

86

50 51

50G 51G

86

50 51

50G 51G

86

50 51

50G 51G

86

50 51

50G 51G

86

51 51G 51 51G

2000A, 3PH, 3W, 13.8KVSWGR 3

NIH3M2000AFN.C.

NIH3T2000AFN.C.

50 51

DPR

87

50G 51G

86

50 51

50G 51G

86

50 51

50G 51G

86

50 51

50G 51G

86

50 51

50G 51G

86

50 51

50G 51G

86

50 51

50G 51G

86

51 51G 51 51G

1200AF 1200AF 1200AF 1200AF 1200AF 1200AF 1200AF 1200AF 1200AF 1200AF 1200AF 1200AF 1200AF 1200AF

1200AF 1200AF 1200AF 1200AF 1200AF 1200AF 1200AF

28 KAIC1

28 KAIC

128 KAIC

11 11

11

11

11 11

12 12

12

9 9

9

10101010101010101010101010

10 10 10 10 10

PEPCO

NIH

52 52 52 52 52 52 52

52 52

52 52 52 52

52

52 5252

52

52 52 52 52

52

52 5252

52

52 52

52

52 52

52

52 52

52

52 52

30 MVA34.5-13.8 KV

PEPCOFEEDER

34002

N.C. N.C.

N.C.

33.6 MVA34.5-13.8 KV

PEPCOFEEDER

34009

N.C. N.C.

N.C.

20 MVA34.5-13.8 KV

PEPCOFEEDER

34001

N.C. N.C.

N.C.

20 MVA34.5-13.8 KV

PEPCOFEEDER

34010

N.C. N.C.

1. REFER TO DRAWINGS ED201 AND ED602 FOR MOREINFORMATION.

GENERAL DRAWING NOTES:

DISCONNECT AND REMOVE EXISTING SWITCHGEAR.

COORDINATE 13.8 KV BUSWAY MODIFICATIONS OR REPLACEMENTWITH PEPCO.

DISCONNECT AND REMOVE EXISTING 13.8 KV FEEDERS BACK TO NEWJUNCTION BARS IN MANHOLES.

DISCONNECT AND REMOVE EXISTING ATS, PANELBOARD, AND METER.COORDINATE WITH PEPCO.

DISCONNECT AND REMOVE EXISTING BATTERY CHARGER.

DISCONNECT AND REMOVE EXISTING BATTERIES.

DISCONNECT AND REMOVE EXISTING 125V DC SWITCHBOARD.

COORDINATE FEEDER MODIFICATIONS WITH PEPCO.

EXISTING GE MODEL 12IFC53A1A RELAY.

EXISTING GE MODEL 12IFC53B1A RELAY.

EXISTING GE MODEL MULTILIN 850 RELAY.

EXISTING GE MODEL 12VPVD21B1A RELAY.

SPECIFIC DRAWING NOTES:1

2

3

4

5

6

7

8

9

10

11

12

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

OFFICE OFRESEARCH FACILITIES

PRO

JEC

TTI

TLE

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEAL

CO

NTR

ACTO

RS

BUIL

DIN

GPR

OJE

CT

DR

AWIN

GA/

E N

ame

and

LOG

O

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

11/2

/201

7 4:

01:3

1 PM

C:\U

sers

\mic

hael

.klin

e.ED

G2\

Doc

umen

ts\R

evit

2015

\160

18E-

R20

15_m

icha

el.k

line.

rvt

ED501

MK

MK

GC

Project Number

SIN

GLE

LIN

E D

IAG

RAM

- EX

ISTI

NG

&D

EMO

LITI

ON

24

N.T.S.1 SINGLE LINE DIAGRAM - EXISTING & DEMOLITION

Page 5: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

RESERVETIE 1

1A

1B

V/T

FEEDER6

2A

2B

FEEDER1

3A

3B

FEEDER4

FEEDER5

4A

4B

FEEDER3

FEEDER2

5A

5B

FEEDER7

MAIN 1

6A

6B

V/T

SWGR 1

RESERVETIE 2

7A

7B

V/T

FEEDER15

8A

8B

FEEDER14

FEEDER16

9A

9B

FEEDER11

FEEDER13

10A

10B

FEEDER12

FEEDER17

11A

11B

MAIN 2

12A

12B

SWGR 2

MAIN 3

13A

13B

FEEDER21

14A

14B

FEEDER25

15A

15B

FEEDER19

FEEDER26

16A

16B

FEEDER18

FEEDER27

17A

17B

FEEDER20

RESERVETIE 3

18A

18B

SWGR 3

V/T

V/T V/TSPACE

SPACE

SPACE

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

OFFICE OFRESEARCH FACILITIES

PRO

JEC

TTI

TLE

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEAL

CO

NTR

ACTO

RS

BUIL

DIN

GPR

OJE

CT

DR

AWIN

GA/

E N

ame

and

LOG

O

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

11/2

/201

7 4:

01:3

2 PM

C:\U

sers

\mic

hael

.klin

e.ED

G2\

Doc

umen

ts\R

evit

2015

\160

18E-

R20

15_m

icha

el.k

line.

rvt

ED601

MK

MK

GC

Project Number

SWIT

CH

GEA

R E

LEVA

TIO

N -

EXIS

TIN

G &

DEM

OLI

TIO

N

25

N.T.S.1 SWITCHGEAR ELEVATION - DEMOLITION

Page 6: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

BUILDING 17

EN-93

EN-101

EN-100

EN-96

EN-90

FEEDERS 2,7, 13, 17, 21,27

EN-102

FEEDERS 3, 12, 19

EN-92

FEEDERS14, 20

EN-88

FEEDERS 1,4, 11, 14, 18

EN-89

FEEDER 20

EN-99

FEEDER 14

EN-98

FEEDERS5, 6, 15, 16,25, 26

EN-94

EN-95

FEEDERS3, 7, 12, 14,17, 19, 20,27

FEEDERS 17, 27

FEEDERS 1, 3,4A, 4B, 7, 11A,11B, 12, 14,18A, 18B, 19, 20

FEEDERS3, 7, 12, 14,20

FEEDERS2, 13, 21

FEEDERS5, 6, 15, 16,25, 26

EMPTY

2

2

1

1

1

1

3

1

1EMPTY

EMPTY

3

4

1. DRAWINGS ARE DIAGRAMMATIC.

2. REFER TO DRAWINGS ED002 AND ED603 FOR MOREINFORMATION.

GENERAL DRAWING NOTES:

DISCONNECT AND REMOVE EXISTING FEEDERS AND DUCT BANK.

DISCONNECT AND REMOVE EXISTING FEEDERS. CONTRACTOR TOREMOVE DUCT BANK ONLY IF REQUIRED TO ACCOMODATE NEWWORK.

DISCONNECT AND REMOVE EXISTING FEEDERS. DUCT BANK TOREMAIN AND BE REUSED.

DISCONNECT AND REMOVE EXISTING FEEDERS 1, 4, 11, AND 18.DUCT BANK TO REMAIN AND BE REUSED.

SPECIFIC DRAWING NOTES:1

2

3

4

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

OFFICE OFRESEARCH FACILITIES

PRO

JEC

TTI

TLE

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEAL

CO

NTR

ACTO

RS

BUIL

DIN

GPR

OJE

CT

DR

AWIN

GA/

E N

ame

and

LOG

O

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET 26 OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

11/2

/201

7 4:

01:3

3 PM

C:\U

sers

\mic

hael

.klin

e.ED

G2\

Doc

umen

ts\R

evit

2015

\160

18E-

R20

15_m

icha

el.k

line.

rvt

ED602

Designer

Author

Checker

Project Number

MAN

HO

LE P

LAN

- EX

ISTI

NG

& D

EMO

LITI

ON

N.T.S.1 PARTIAL MANHOLE PLAN - DEMOLITION

Page 7: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

FDR 27 (E)

3658 (12'0")

3150 (10'4")

1829 (6'0")

NORTH

TO MHEN-92

TO MHEN-102

TO MHEN-90

FDR 17 (E)

FDR 21 (E)

FDR 13 (E)

FDR 7 (E)FDR 2 (E)

SS

S S S

S S S S S S

SS

S

X X

X X

X X X X

X

XXXX

XXS

TO BLDG 17

TO MHEN-94

TO MHEN-95

TO BLDG 17

TO BLDG 17

FDR 20 (D)

FDR 14 (D)

S

S

S

S

X X X X

X X X X

X X X X

X X X

X

FDR 21 (D)

FDR 13 (D)

FDR 19 (D)FDR 17 (D)

FDR 14 (D)FDR 27 (D)

FDR 20 (D)

FDR 12 (D)FDR 27 (D)

FDR 3 (D)FDR 12 (D)

FDR 19 (D)

3099 (10'2")3658 (12'0")

1829 (6'0")

NORTH

TO MHEN-93

TO MHEN-100

XXXX

XXS

XXX

TO MHEN-95

TO BLDG 17

X

X

X

FDR 14 (D)

FDR 17 (D)FDR 20 (D)

FDR 27 (D)

FDR 7(D)

FDR 14 (D)FDR 3 (D)

FDR 20 (D)

FDR 17 (D)

FDR 27 (D)

FDR 3 (D)

FDR 7 (D)FDR 19 (D)

FDR 12 (D)

FDR 12 (D)

FDR 19 (D)

3048 (10'0")

3048 (10'0")

1981 (6'6")

NORTH

S

SS

S S

S

SS

S S

S

S

S

S

S

S

S

SS

S

S

S

S

S

SS

S

SS

S S

FDR 3 (E)FDR 19 (E)

FDR 12 (E)

TO MHEN-103

TO UNKNOWN

FDR 12 (E)

TO MHMH-2

FDR 3 (D)

FDR 12 (D)

FDR 19 (D)

2438 (8'0")

1829 (6'0")

1524 (5'0")

S

TO BLDG21

TO MHEN-93

FDR 14 (E)

FDR 20 (E)

NORTH

FDR 14 (D)

FDR 20 (D)

3048 (10'0")

2438 (8'0")

3048 (10'0")

NORTH

TO BLDG 17

TO BLDG 17

TO BLDG 17

X X X X X

SSXXX

X X X S S

XXXXX

S

S

X

X X

X

TO MHEN-93

X X X X

X X X X

X X X X

X X X

1. DRAWINGS ARE DIAGRAMMATIC.

2. REFER TO DRAWINGS ED002, ED602, AND ED604 FOR MOREINFORMATION.

GENERAL DRAWING NOTES:

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

OFFICE OFRESEARCH FACILITIES

PRO

JEC

TTI

TLE

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEAL

CO

NTR

ACTO

RS

BUIL

DIN

GPR

OJE

CT

DR

AWIN

GA/

E N

ame

and

LOG

O

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET 27 OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

11/2

/201

7 4:

01:3

4 PM

C:\U

sers

\mic

hael

.klin

e.ED

G2\

Doc

umen

ts\R

evit

2015

\160

18E-

R20

15_m

icha

el.k

line.

rvt

ED603

Designer

Author

Checker

Project Number

MAN

HO

LE F

OLD

OU

TS -

EXIS

TIN

G &

DEM

OLI

TIO

N

N.T.S.3 MANHOLE EN-93 - EXISTING & DEMOLITION

N.T.S.2 MANHOLE EN-101 - EXISTING & DEMOLITIONN.T.S.4 MANHOLE EN-102 - EXISTING & DEMOLITION

N.T.S.5 MANHOLE EN-92 - EXISTING & DEMOLITION

N.T.S.1 MANHOLE EN-94 - EXISTING & DEMOLITION

Page 8: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

1829 (6'0")

3658 (12'0")3048 (10'0")

TO MHEN-101

TO T-69

TO MHEN-95

NORTH

S S

S

S S

SS

S

SS

FDR 14 (E)

FDR 14 (E)

2438 (8'0")

3658 (12'0")

2438 (8'0")

FDR 15 (D)

FDR 25 (D)

FDR 5 (D)

FDR 15 (D)

NORTH

TO MHEN-98

FDR 16 (E)

FDR 6 (E)FDR 6 (E)

FDR 16 (E)FDR 26 (E)

FDR 26 (E)

FDR 25 (E)FDR 5 (E)

FDR 15 (E)

FDR 15 (E)

FDR 25 (E)FDR 5 (E)

S S S S

S

S

XX

TOBLDG 17

FDR 16 (D)

FDR 5 (D)

FDR 26 (D)

FDR 16 (D)

FDR 26 (D)FDR 25 (D)

FDR 6 (D)

FDR 6 (D)

3429 (11'3") 3658 (12'0")

1829 (6'0")

NORTH

TO MH EN-88& MH EN-89

TO MHEN-99

FDR 14 (E)

X

X

X

X X X

X X X

XX

X

XX

FDR 14 (E)

TO MH EN-101

TO BLDG 17

TO BLDG 17

TO MHEN-95

FDR 18 (D)FDR 18 (D)

FDR 1 (D)

FDR 11 (D)FDR 20 (D)

FDR 4 (D)

FDR 4 (D)

FDR 11 (D)

SS

SS

SS

SS

S

S

X

X

X

X

X

X

XX

XX

FDR 12 (D)

FDR 19 (D)

FDR 18 (D)

FDR 4 (D)FDR 3 (D)

FDR 1 (D)

FDR 11 (D)FDR 14 (D)

FDR 7 (D)

FDR 20 (D)

FDR 14 (D)

FDR 7 (D)FDR 20 (D)

FDR 3 (D)

FDR 19 (D)

FDR 12 (D)

2438 (8'0")

1829 (6'0")

1524 (5'0")

X

X

X

X X S X

S S

TO MHEN-100

TO MHEN-78

FDR 20 (E)

TO MHEN-87

NORTH

FDR 20 (D)

FDR 11 (E)

2438 (8'0")

1524 (5'0")

2667 (8'8")

X

XS

X

S

S

S

X

XX S

FDR 14 (E)

S

FDR 11 (E)

FDR 4 (E)FDR 4 (E)

FDR 18 (E)

FDR 1 (E)

FDR 25 (E)

FDR 18 (E)

FDR 14 (E)

TO MHEN-100

TO MHEN-87

NORTH

FDR 4 (D)

FDR 1 (D)

FDR 11 (D)

FDR 18 (D)

FDR 4 (D)

FDR 11 (D)

FDR 18 (D)

FDR 1 (D)

1. DRAWINGS ARE DIAGRAMMATIC.

2. REFER TO DRAWINGS ED002, ED602, AND ED604 FOR MOREINFORMATION.

GENERAL DRAWING NOTES:

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

OFFICE OFRESEARCH FACILITIES

PRO

JEC

TTI

TLE

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEAL

CO

NTR

ACTO

RS

BUIL

DIN

GPR

OJE

CT

DR

AWIN

GA/

E N

ame

and

LOG

O

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET 28 OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

11/2

/201

7 4:

01:3

5 PM

C:\U

sers

\mic

hael

.klin

e.ED

G2\

Doc

umen

ts\R

evit

2015

\160

18E-

R20

15_m

icha

el.k

line.

rvt

ED604

Designer

Author

Checker

Project Number

MAN

HO

LE F

OLD

OU

TS -

EXIS

TIN

G &

DEM

OLI

TIO

N

N.T.S.2 MANHOLE EN-99 - EXISTING & DEMOLITIONN.T.S.1 MANHOLE EN-96 - EXISTING & DEMOLITION

N.T.S.3 MANHOLE EN-100 - EXISTING & DEMOLITION

N.T.S.4 MANHOLE EN-89 - EXISTING & DEMOLITION

N.T.S.5 MANHOLE EN-88 - EXISTING & DEMOLITION

Page 9: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

TEMPSWGR 3

TEMPSWGR 2

TEMPSWGR 1

1ET201

TEMP OUTDOORSWGR 1

TEMP OUTDOORSWGR 2

TEMP OUTDOORSWGR 3

2

3

4

SWGR 3

SWGR 1

SWGR 2

5

5

EN-93

EN-101

EN-100

EN-99

EN-95

EN-114

EN-115

EN-96

PEPCO AREA

PEPCO AREA

EN-94

EN-94

EN-93

EN-101

EN-100

EN-99

T-69

EN-95

EN-114

EN-115EN-96

EN-98

EN-102

EN-92

EN-89

EN-88

EN-90

1. ALL NEW COMPONENTS WILL BE DESIGNED IN ACCORDANCEWITH THE NIH DRM AND PEPCO REQUIREMENTS.

2. REFER TO DRAWINGS ET201 AND ET501 FOR MOREINFORMATION.

3. DRAWINGS ARE DIAGRAMMATIC

4. CONTRACTOR MAY ELECT TO UTILIZE OTHER MEANS ANDMETHODS OF PROVIDING TEMPORARY POWER, WITH THEAPPROVAL OF NIH AND PEPCO, AT NO ADDITIONAL COST TO THEOWNER.

GENERAL DRAWING NOTES:

PROPOSED TEMPORARY FEEDER ROUTING. PROVIDE RACK ANDCONDUIT STRUCTURE FOR TEMPORARY FEEDERS AS REQUIRED.PROVIDE DESIGN OF STRUCTURE STAMPED AND SIGNED BY ALICENSED STRUCTURAL ENGINEER.

EXTEND TEMPORARY FEEDER ROUTING STRUCTURE TO MANHOLEEN-102.

EXTEND TEMPORARY FEEDER ROUTING STRUCTURE TO MANHOLEEN-92.

EXTEND TEMPORARY FEEDER ROUTING STRUCTURE TO MANHOLESEN-88 AND EN-89.

OUTLINE OF EXISTING SWITCHGEAR TO BE DEMOLISHED. REFER TODRAWING ET501 FOR PHASING PLAN AND FOR MORE INFORMATION.

SPECIFIC DRAWING NOTES:1

2

3

4

5

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

OFFICE OFRESEARCH FACILITIES

PRO

JEC

TTI

TLE

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEAL

CO

NTR

ACTO

RS

BUIL

DIN

GPR

OJE

CT

DR

AWIN

GA/

E N

ame

and

LOG

O

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET OF 32

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

BUILDING 17

BUILDING 21

2/6/

2018

5:0

0:42

PM

C:\U

sers

\mic

hael

.klin

e.ED

G2\

Doc

umen

ts\R

evit

2015

\160

18E-

R20

15_m

icha

el.k

line.

rvt

ET002

Designer

Author

Checker

Project Number

ELEC

TRIC

AL S

ITE

PLAN

- TE

MPO

RAR

Y

1 : 1252 ELECTRICAL SITE PLAN - TEMPORARY

0 62503125

1:125

N

0 2500012500

1:500

1 : 5001 ELECTRICAL MANHOLE PLAN - EXISTING

Page 10: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

DN

TEMPORARYSERVICE

ENTRANCESWGR 3

TEMPORARYSERVICE

ENTRANCESWGR 2

TEMPORARYSERVICE

ENTRANCESWGR 1

PEPCO BUSSECTION 3

PEPCO BUSSECTION 4

PEPCO BUSSECTION 2

PEPCO BUSSECTION 1

1

TEMPORARYFEEDERS(TYPICAL)

1

2

3

4

5

6

7

A 1. FEEDER ROUTING IS DIAGRAMMATIC.

2. ALL TEMPORARY COMPONENTS WILL BE DESIGNED INACCORDANCE WITH PEPCO REQUIREMENTS.

3. COORDINATE TEMPORARY POWER CONNECTIONS WITH PEPCO.

3. REFER TO DRAWINGS ET002 & ET501 FOR MORE INFORMATION.

GENERAL DRAWING NOTES:

REFER TO DRAWING ET002 FOR CONTINUATION.

SPECIFIC DRAWING NOTES:1

1 : 1001 SWITCHGEAR LEVEL - POWER - TEMPORARY

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

KEY PLANSCALE: N.T.S.

OFFICE OFRESEARCH FACILITIES

PRO

JEC

TTI

TLE

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEAL

CO

NTR

ACTO

RS

BUIL

DIN

GPR

OJE

CT

DR

AWIN

GA/

E N

ame

and

LOG

O

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET 30 OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

BUILDING 17

BUILDING 21

11/2

/201

7 4:

01:3

6 PM

C:\U

sers

\mic

hael

.klin

e.ED

G2\

Doc

umen

ts\R

evit

2015

\160

18E-

R20

15_m

icha

el.k

line.

rvt

ET201

Designer

Author

Checker

Project Number

POW

ER P

LAN

- TE

MPO

RAR

Y

N

Page 11: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

TVSSTVSS TVSS

FDR 1TO BLDGS 2, 3,

4, 5 & 10(VAULTS 12 &

13)

FDR 4TO BLDG 59 &

BLDG 10(VAULTS 1, 2,

3, 4, & 5)

FDR 2TO BLDGS

12A, 12UPPER, 12

LOWER & 50

FDR 6TO BLDG 11

(4,160 V)

FDR 5TO BLDG 57

FDR 3TO BLDG 33 &

MLP-10

FDR 7TO BLDGS 6,

6A, 6B, 8, 13N,14A, 14B, 31A,

31B, & 31C

FDR 15TO BLDG 57

FDR 14TO BLDGS 3, 4,5, 16A, 16B, 21,

21B, & TG9

FDR 16TO BLDG

11 (4,160 V)

FDR 11TO BLDG 59

FDR 13TO BLDGS 12A,12 UPPER, 12

LOWER, 12E, 12GARAGE, & 50

FDR 12TO BLDGS 33

& 67

FDR 17TO BLDGS 6,

6A, 6B, 8, 13S,14A, 14B, 31A,

31B, & 31C

FDR 21TO BLDGS 12A,

12 UPPER, 12LOWER, 12E, 12GARAGE, & 50

FDR 25TO BLDG 57

FDR 19TO BLDG 33 &

UTILITYTUNNEL

FDR 26TO BLDG 11

(4,160 V)

FDR 18TO BLDG 59

FDR 27TO BLDGS 6, 6A,6B, 8, 13S, 13N,14A, 31A, 31B, &

31C

FDR 20TO BLDGS1, 2, 4, 5, 10

(VAULTS 12 &13), & 21

1200AF

FMR

50 51

SUBSTATION RELAY

1200AF

FMR

50 51

1200AF

FMR

50 51

1200AF

FMR

50 51

1200AF

FMR

50 51

1200AF

FMR

50 51

1200AF

FMR

50 51

2000A, 3PH, 3W, 13.8KVTEMPORARY OUTDOOR SWGR 1

TO PEPCO

2

6

PEPCOMETER

6 6 65 5 5

4

TEMPORARY INDOOR SWGR 12000A, 3PH, 3W, 13.8KV

1

3

2000AF2000AT

50 5132

8667PQM

51G

14,400/120V

1200:5

1200AF

FMR

50 51

1200AF

SUBSTATION RELAY

FMR

50 51

1200AF

5150

FMR

1200AF

FMR

1200AF

50

FMR

1200AF

50 51

1200AF

FMR

51

TEMPORARY OUTDOOR SWGR 2

50 51 51

FMR

50

2000A, 3PH, 3W, 13.8KV

TO PEPCO

2

6

PEPCOMETER

6 6 65 5 5

4

TEMPORARY INDOOR SWGR 22000A, 3PH, 3W, 13.8KV

1

3

2000AF2000AT

50 5132

8667PQM

51G

14,400/120V

1200:5

1200AF

FMR

50 51

1200AF

SUBSTATION RELAY

FMR

50 51

1200AF

5150

FMR

1200AF

FMR

1200AF

50

FMR

1200AF

50 51

1200AF

FMR

51

TEMPORARY OUTDOOR SWGR 3

50 51 51

FMR

50

2000A, 3PH, 3W, 13.8KV

TO PEPCO

2

6

PEPCOMETER

6 6 65 5 5

4

TEMPORARY INDOOR SWGR 32000A, 3PH, 3W, 13.8KV

1

3

2000AF2000AT

50 5132

8667PQM

51G

14,400/120V

1200:5

300:5 300:5 300:5 600:5 300:5600:5 600:5 300:5 300:5 300:5 600:5 300:5600:5 600:5 300:5 300:5 300:5 600:5 300:5600:5 600:5

M M M

G3

G3

G3

52

52

52 52 52 52 52 52

52

52 52 52 5252 52 52

52

52 52 52 5252 52 52

PHASING NOTES

c. DISCONNECT AND REMOVE EXISTING SWITCHGEAR 3 AND ALL ASSOCIATED WIRING ANDRACEWAYS.

d. PROVIDE TEMPORARY SWITCHGEARS 1 AND 2 COMPLETE WITH FEEDERS AND ALL OTHERAPPURTANCES AS REQUIRED TO MAINTAIN THE CONTINUITY OF POWER TO THE EXISTINGSWITCHGEAR 1 AND 2 ELECTRICAL LOADS.

e. TRANSFER LOADS FROM EXISTING SWITCHGEAR 2 TO TEMPORARY 2.f. DISCONNECT AND REMOVE EXISTING SWITCHGEAR 2 AND ALL ASSOCIATED WIRING AND

RACEWAYS.e. TRANSFER LOADS FROM EXISTING SWITCHGEAR 1 TO TEMPORARY 1.f. DISCONNECT AND REMOVE EXISTING SWITCHGEAR 1 AND ALL ASSOCIATED WIRING AND

RACEWAYS.g. DEMOLISH DUCT BANKS TO BE DEMOLISHED.h. PROVIDE NEW DUCT BANKS.i. PROVIDE NEW UNDERGROUND DUCTS FOR SWITCHGEARS 1 AND 2.j. PROVIDE NEW PERMANENT SWITCHGEARS 1 AND 2.k. TEST AND COMMISSION NEW ELECTRICAL DISTRIBUTION EQUIPMENT AND SCADA SYSTEM.l. TRANSFER LOADS FROM TEMPORARY SWITCHGEAR 1 TO NEW PERMANENT SWITCHGEAR 1.j. TRANSFER LOADS FROM TEMPORARY SWITCHGEAR 2 TO NEW PERMANENT SWITCHGEAR 2.k. DISCONNECT AND REMOVE TEMPORARY SWITCHGEARS 1 AND 2 AND ALL ASSOCIATED WIRING

AND RACEWAYS.g. PROVIDE NEW UNDERGROUND DUCTS FOR SWITCHGEAR 3.h. PROVIDE NEW PERMANENT SWITCHGEAR 3.i. TEST AND COMMISSION NEW ELECTRICAL DISTRIBUTION EQUIPMENT AND SCADA SYSTEM.j. TRANSFER LOADS FROM TEMPORARY SWITCHGEAR 3 TO NEW PERMANENT SWITCHGEAR 3.k. DISCONNECT AND REMOVE TEMPORARY SWITCHGEAR 3 AND ALL ASSOCIATED WIRING AND

RACEWAYS.

I. GENERALa. THIS IS A DESIGN BID PROJECT AND THIS IS A HIGH LEVEL PHASING PLAN. THE CONTRACTOR WILL

PROVIDE A DETAILED PHASING PLAN COMPLETE WITH METHODS AND PROCEDURES (MOPS) FORREVIEW, APPROVAL, AND COORDINATION WITH NIH PRIOR TO EXECUTION OF WORK.

b. THE MOPS WILL PROVIDE A COORDINATED CONSTRUCTION PHASING PLAN TO MINIMIZEDOWNTIME TO THE AFFECTED FACILITIES. THE MOP SHALL INCLUDE BACK-OUT PROCEDURES TORETURN THE INFRASTRUCTURE TO ITS ORIGINAL STATE IF A MOP IS DISRUPTED.

c. ALL EXISTING SYSTEMS ARE TO OPERATE CONCURRENTLY AND CONTINUOUSLY, EXCEPT ASDESCRIBED HEREIN.

d. THE WORK SCHEDULE IN OCCUPIED AREAS SHALL BE COORDINATED AND AGREED UPON BY NIH.II. INFRASTRUCTURE MODIFICATION APPROVAL PROCESS

a. MOPS AND SCHEDULE SHALL BE SUBMITTED AND APPROVED BY NIH PRIOR TO INTERRUPTINGANY LIVE CIRCUITS OR SHUT DOWN OF ANY SYSTEM. NIH RESERVES THE RIGHT TO POSTPONEAPPROVED SHUT DOWNS AT THEIR DISCRETION. ALL OUTAGES SHALL BE SCHEDULED WITH NIHWITH A MINIMUM OF TWO WEEKS NOTICE PRIOR TO THE NEED OF A SHUT DOWN OF ANY SYSTEM.

b. INTERRUPTION SHALL BE PERFORMED IN COORDINATION WITH NIH, USING OSHA LOCKOUT ANDTAGOUT PROCEDURES.

c. ANY WORK THAT COULD IMPACT NIH'S PRODUCTION ENVIRONMENT SHALL BE PERFORMED USINGNIH'S CHANGE CONTROL PROCESS.

d. ANY WORK THAT COULD IMPACT NIH'S LIFE SAFETY SYSTEMS SHALL BE PERFORMED USING NIH'SBURN PERMIT PROCESS AND WITH A FIRE WATCH ON DUTY FOR THE DURATION OF THE OUTAGE.

e. THE CONTRACTOR SHALL COORDINATE ALL INCOMING UTILITY SERVICE OUTAGES WITH PEPCOAND NIH.

III. CONSTRUCTION PHASING:a. PROVIDE TEMPORARY SWITCHGEAR 3 COMPLETE WITH FEEDERS AND ALL OTHER APPURTANCES

AS REQUIRED TO MAINTAIN THE CONTINUITY OF POWER TO THE EXISTING SWITCHGEAR 3ELECTRICAL LOADS.

b. TRANSFER ALL EXISTING ACTIVE LOADS FROM EXISTING SWITCHGEAR 3 TO TEMPORARYSWITCHGEAR 3.

1. ALL TEMPORARY COMPONENTS WILL BE DESIGNED INACCORDANCE WITH THE NIH DRM AND PEPCO REQUIREMENTS.

2. REFER TO DRAWINGS ET002 AND ET201 FOR MOREINFORMATION.

3. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTSASSOCIATED WITH PROVIDING TEMPORARY POWER INCLUDING,BUT NOT LIMITED TO, PROVIDING TEMPORARY SWITCHGEAR,TEMPORARY FEEDERS, & TEMPORARY CONDUIT STRUCTURE.

4. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALLASPECTS OF WORK REQUIRED FOR THE PROVISION OFTEMPORARY POWER.

5. CONTRACTOR MAY ELECT TO UTILIZE OTHER MEANS ANDMETHODS OF PROVIDING TEMPORARY POWER, WITH WRITTENAPPROVAL FROM NIH AND PEPCO, AT NO ADDITIONAL COST TOTHE OWNER.

GENERAL DRAWING NOTES:

PROVIDE NEW TEMPORARY INDOOR 2000A, 3PH, 3W, 13.8 KVSWITCHGEAR.

PROVIDE NEW TEMPORARY OUTDOOR 2000A, 3PH, 3W, 13.8 KVSWITCHGEAR.

COORDINATE INSTALLATION OF TEMPORARY FEEDERS WITH PEPCO.

PROVIDE 5 SETS OF (3#500KCMIL) 15KV CABLES IN 5" CONDUITS.

PROVIDE 2 SETS OF (3#500KCMIL) CABLES IN 5" CONDUITS.

PROVIDE 1 SET OF (3#500KCMIL) 15KV CABLES IN 5" CONDUITS.

SPECIFIC DRAWING NOTES:1

2

3

4

5

6

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

OFFICE OFRESEARCH FACILITIES

PRO

JEC

TTI

TLE

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEAL

CO

NTR

ACTO

RS

BUIL

DIN

GPR

OJE

CT

DR

AWIN

GA/

E N

ame

and

LOG

O

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET 31 OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

11/2

/201

7 4:

01:3

7 PM

C:\U

sers

\mic

hael

.klin

e.ED

G2\

Doc

umen

ts\R

evit

2015

\160

18E-

R20

15_m

icha

el.k

line.

rvt

ET501

Designer

Author

Checker

Project Number

SIN

GLE

LIN

E D

IAG

RAM

- TE

MPO

RAR

Y

N.T.S.1 TEMPORARY SINGLE LINE DIAGRAM

Page 12: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

EN-93

EN-101

EN-100

EN-99

EN-95

EN-114

EN-115

EN-96

PEPCO AREA

PEPCO AREA

EN-94

1E-201

SWGR 1

SWGR 2

SWGR 3

1

1

1

1

1

1

2TYP

EN-94

EN-93

EN-101

EN-100

EN-99

T-69

EN-95

EN-114

EN-115EN-96

EN-98

EN-102

EN-92

EN-89

EN-88

EN-90

1. DUCT BANK ROUTES ARE DIAGRAMMATIC. CONTRACTOR TODETERMINE BEST ROUTE IN THE FIELD.

2. REFER TO DRAWINGS E-602, E-603, AND E-604 FOR MOREINFORMATION.

GENERAL DRAWING NOTES:

PROVIDE NEW 20-WAY DUCT BANK.

COORDINATE DUCT STUB UP LOCATIONS WITH SWITCHGEARMANUFACTURER'S RECOMMENDED CONDUIT LOCATIONS.

SPECIFIC DRAWING NOTES:1

2

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

KEY PLANSCALE: N.T.S.

OFFICE OFRESEARCH FACILITIES

PRO

JEC

TTI

TLE

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEAL

CO

NTR

ACTO

RS

BUIL

DIN

GPR

OJE

CT

DR

AWIN

GA/

E N

ame

and

LOG

O

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET 32 OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

BUILDING 17

BUILDING 21

11/2

/201

7 4:

01:1

8 PM

C:\U

sers

\mic

hael

.klin

e.ED

G2\

Doc

umen

ts\R

evit

2015

\160

18E-

R20

15_m

icha

el.k

line.

rvt

E-002

Designer

Author

Checker

Project Number

ELEC

TRIC

AL S

ITE

PLAN

- N

EW W

OR

K

1 : 1252 ELECTRICAL SITE PLAN - NEW WORK

0 62503125

1:125

N

0 2500012500

1:500

1 : 5001 ELECTRICAL MANHOLE PLAN - EXISTING

Page 13: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

DN

3

3

LUMINAIRE SCHEDULETYPE MANUFACTURER SERIES NUMBER LAMP TYPE DESCRIPTIONMOUNTING

A

WATTS VOLTS

LITHONIA 70 PENDANTLEDZL2NL482000LM 120V

DECO LIGHTING 50 PENDANTLEDDACH-LED-4-50 120V

COLUMBIA 48 PENDANTLEDLCS4-35ML 120V

4' STRIP

EMERGENCY LIGHTING FIXTURE. PROVIDEWITH BACK-UP, SEALED, MAINTENANCE FREENICKEL-CADMIUM BATTERY. BATTERY SHALLDELIVER 120 MINUTES POWER BACK UP.PROVIDE SELF-TESTING FIXTURES.

LITHONIA 2 WALLLEDLE-S-W-1-R-ELN 120V

HUBBELL 4LEDLX-U-R-W-E 120V

EATON 1LEDCX71SD 120V

WALL

WALL

OUTDOOR LIGHTING FIXTURE. PROVIDEWITH PHOTOCELL.LITHONIA 40LEDTWH-LED 120V

DECO LIGHTING 40LEDD404-LED 120V

HUBBELL 32LEDPVL3 120V

WALL

WALL

WALL

B

EMERGENCY LIGHTING FIXTURE. PROVIDEWITH BACK-UP, SEALED, MAINTENANCE FREENICKEL-CADMIUM BATTERY. BATTERY SHALLDELIVER 120 MINUTES POWER BACK UP.PROVIDE SELF-TESTING FIXTURES.

120V

120V

120V

WALL

WALL

WALL

LED

LED

LED

LITHONIA ELM2 LED HO SD 2

HUBBELL LZ

ABB LCAB-2SQLEDRID

3

3

1

2

3

4

5

6

7

A

A

54SS-31

A A

A A A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

B

54SS-33

1. COORDINATE WITH ALL CABLETRAYS, CONDUITS, ANDSWITCHGEAR LOCATION FOR LAYOUT AND INSTALLATION OF NEWLIGHTING FIXTURES.

GENERAL DRAWING NOTES:

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

KEY PLANSCALE: N.T.S.

OFFICE OFRESEARCH FACILITIES

PRO

JEC

TTI

TLE

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEAL

CO

NTR

ACTO

RS

BUIL

DIN

GPR

OJE

CT

DR

AWIN

GA/

E N

ame

and

LOG

O

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

BUILDING 17

BUILDING 21

11/2

/201

7 4:

01:1

9 PM

C:\U

sers

\mic

hael

.klin

e.ED

G2\

Doc

umen

ts\R

evit

2015

\160

18E-

R20

15_m

icha

el.k

line.

rvt

E-101

MK

MK

GC

Project Number

LIG

HTI

NG

PLA

N -

NEW

WO

RK

33

1 : 1001 SWITCHGEAR LEVEL - NEW WORK - LIGHTING

0 50002500

1:100

N

Page 14: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

DN

1

2

3

4

5

6

7

A

SWGR 2

1

2

TYP.

BATTERIES

BATTERYCHARGER

PEPCO METER

ATS

DDF CONTROL

REVENUEMETERS

EXISTINGSCADA SYSTEMENCLOSURE

SWGR 3

SWGR 1

3

3

3

3

3

4

4

4

4

4

5

5

5

5

5

DC PANEL

NEW SCADA SYSTEMENCLOSURE

NEW REMOTEINTERFACE PANEL

H

H

H

54SS-2

54SS-14

54SS-8

EF-13/4HP208V

54SS-7

54SS-1

54SS-17

54SS-19J

54SS-37

JJ

54SS-41

6

7NEWSUPERVISORYPANEL

J 8

54SS-35

CU-1

54SS-26

CU-1

54SS-32

RELOCATED MANHOLE COVER OF MANHOLE EN-94. REFER TOSTRUCTURAL DRAWINGS FOR MORE INFORMATION.

2000A, 13.8 KV BUS DUCT FROM PEPCO. COORDINATE ALLREQUIRED MODIFICATIONS OR REPLACMENT WITH PEPCO.

PROVIDE NEW 127 MM (5") DUCTS TO NEW MANHOLE EN-93.

PROVIDE NEW 127 MM (5") DUCTS TO MANHOLE EN-101.

PROVIDE NEW 127 MM (5") DUCTS TO NEW MANHOLE EN-100.

POWER CONNECTION FOR FOR MOTORIZED DAMPER. REFER TOMECHANICAL DRAWINGS FOR EXACT LOCATION.

POWER CONNECTION FOR SECURITY PANEL. REFER TO TELECOMMDRAWINGS FOR MORE INFORMATION.

POWER CONNECTION FOR HYDROGEN SENSOR AND MONITORINGSYSTEM. REFER TO MECHANICAL DRAWINGS FOR MOREINFORMATION.

SPECIFIC DRAWING NOTES:1

2

3

4

5

6

7

8

1. ALL NEW COMPONENTS WILL BE DESIGNED IN ACCORDANCEWITH THE NIH DRM AND PEPCO REQUIREMENTS.

2. REFER TO DRAWINGS E-501 & E-601 FOR MORE INFORMATION.

3. REFER TO MECHANICAL, TELECOMM, & FIRE ALARM DRAWINGS FORMORE INFORMATION.

GENERAL DRAWING NOTES:

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

KEY PLANSCALE: N.T.S.

OFFICE OFRESEARCH FACILITIES

PRO

JEC

TTI

TLE

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEAL

CO

NTR

ACTO

RS

BUIL

DIN

GPR

OJE

CT

DR

AWIN

GA/

E N

ame

and

LOG

O

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

BUILDING 17

BUILDING 21

11/2

/201

7 4:

01:2

0 PM

C:\U

sers

\mic

hael

.klin

e.ED

G2\

Doc

umen

ts\R

evit

2015

\160

18E-

R20

15_m

icha

el.k

line.

rvt

E-201

MK

MK

GC

Project Number

POW

ER P

LAN

- N

EW W

OR

K

34

1 : 1001 SWITCHGEAR LEVEL - NEW WORK - POWER

0 50002500

1:100

N

Page 15: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

DN

1

2

3

4

5

6

7

A

1

2

3

TYP.

1. ALL NEW COMPONENTS SHALL BE DESIGNED IN ACCORDANCEWITH THE NIH DRM.

GENERAL DRAWING NOTES:

PROVIDE NEW 6x50 (1/4"x2") GROUND BAR MOUNTED 4267 (14') AFF.COORDINATE LOCATION WITH ALL CABLETRAYS AND CONDUITS.EQUIPMENT AND GROUNDING ELECTRODE CONDUCTORS SHALL BELABELED. LABELING SHALL UTILIZE EMBOSSED BRASS METAL TAGSWITH NYLON TIE WRAPS. SEE DRAWING E-701 FOR GROUND BARDETAIL.

CONNECT NEW GROUND BAR TO EXISTING GROUND LOOP WITH#4/0 COPPER WIRE. CONTRACTOR TO FIELD VERIFY LOCATION OFEXISTING GROUND LOOP.

#4/0 GROUND COPPER CONDUCTOR. PROVIDE A LABEL ON EACHGROUND CONDUCTOR AT EVERY GROUND BAR INDICATING ORIGIN OFTERMINATION.

SPECIFIC DRAWING NOTES:1

2

3

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

KEY PLANSCALE: N.T.S.

OFFICE OFRESEARCH FACILITIES

PRO

JEC

TTI

TLE

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEAL

CO

NTR

ACTO

RS

BUIL

DIN

GPR

OJE

CT

DR

AWIN

GA/

E N

ame

and

LOG

O

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET 35 OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

BUILDING 17

BUILDING 21

11/2

/201

7 4:

01:2

1 PM

C:\U

sers

\mic

hael

.klin

e.ED

G2\

Doc

umen

ts\R

evit

2015

\160

18E-

R20

15_m

icha

el.k

line.

rvt

E-301

Designer

Author

Checker

Project Number

GR

OU

ND

ING

PLA

N -

NEW

WO

RK

0 50002500

1:100

1 : 1001 SWITCHGEAR LEVEL - NEW WORK - GROUNDING

N

Page 16: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

TVSS TVSS

TVSS

FDR 1TO BLDGS 2, 3,

4, 5 & 10(VAULTS 12 &

13)

FDR 4TO BLDG 59 &

BLDG 10(VAULTS 1, 2,

3, 4, & 5)

FDR 2TO BLDGS

12A, 12UPPER, 12

LOWER & 50

FDR 6TO BLDG 11

(4,160 V)

FDR 5TO BLDG 57

FDR 3TO BLDG 33 &

MLP-10

FDR 7TO BLDGS 6,

6A, 6B, 8, 13N,14A, 14B, 31A,

31B, & 31C

FDR 15TO BLDG 57

FDR 14TO BLDGS 3, 4,5, 16A, 16B, 21,

21B, & TG9

FDR 16TO BLDG

11 (4,160 V)

FDR 11TO BLDG 59

FDR 13TO BLDGS 12A,12 UPPER, 12

LOWER, 12E, 12GARAGE, & 50

FDR 12TO BLDGS 33

& 67

FDR 17TO BLDGS 6,

6A, 6B, 8, 13S,14A, 14B, 31A,

31B, & 31C

FDR 21TO BLDGS 12A.

12 UPPER, 12LOWER, 12E, 12GARAGE, & 50

FDR 25TO BLDG 57

FDR 19TO BLDG 33 &

UTILITYTUNNEL

FDR 26TO BLDG 11

(4,160 V)

FDR 18TO BLDG 59

FDR 27TO BLDGS 6, 6A,6B, 8, 13S, 13N,14A, 31A, 31B, &

31C

FDR 20TO BLDGS1, 2, 4, 5, 10

(VAULTS 12 &13), & 21

52 52

52

52 52

52

52 52

52

52 52

30 MVA34.5-13.8 KV

PEPCOFEEDER

34002

N.C. N.C.

N.C.

33.6 MVA34.5-13.8 KV

PEPCOFEEDER

34009

N.C. N.C.

N.C.

20 MVA34.5-13.8 KV

PEPCOFEEDER

34001

N.C. N.C.

N.C.

20 MVA34.5-13.8 KV

PEPCOFEEDER

34010

N.C. N.C.

1200AF

FMR

1200AF

FMR

1200AF

FMR

1200AF

FMR

1200AF

FMR

1200AF

FMR

1200AF

FMR

1200AF

FMR

SUBSTATION RELAY

PQM

50 50G 51 51G 81

59 25 6786

PQM

2000A, 3PH, 3W, 13.8KVSWGR 1

50 51

50G 51G

PAF

67 86

AFD

50 51

50G 51G

PAF

67 86

AFD

50 51

50G 51G

PAF

67 86

AFD

50 51

50G 51G

PAF

67 86

AFD

50 51

50G 51G

PAF

67 86

AFD

50 51

50G 51G

PAF

67 86

AFD

50 51

50G 51G

PAF

67 86

AFD

50 51

50G 51G

PAF

67 86

AFD

DPR

87

PQMPQM PQM PQM PQM PQM PQM PQM

PEPCO

NIH

2

5

3

54SS PANEL200A, 3PH, 4W, 208Y/120V

200AF200AT

100AF100AT

200AF200AT

DCPNL

TOPEPCOAREA

TOPEPCOAREA

BATTERYCHARGER

2

2 2

2000AF2000AT

2000AF2000AT

3 3 3 3 3 3 3 3 3 3 3 3 3

3 3 3 3 3 3 3

6

7

8

G3

PEPCOMETER M

PEPCOMETER M

1200AF

FMR

1200AF

FMR

1200AF

FMR

1200AF

FMR

1200AF

FMR

1200AF

FMR

1200AF

FMR

1200AF

FMR

PQM PQM

2000A, 3PH, 3W, 13.8KVSWGR 2

50 51

50G 51G

PAF

67 86

AFD

50 51

50G 51G

PAF

67 86

AFD

50 51

50G 51G

PAF

67 86

AFD

50 51

50G 51G

PAF

67 86

AFD

50 51

50G 51G

PAF

67 86

AFD

50 51

50G 51G

PAF

67 86

AFD

50 51

50G 51G

PAF

67 86

AFD

50 51

50G 51G

PAF

67 86

AFD

DPR

87

PQMPQM PQM PQM PQM PQM PQM PQM

2000AF2000AT

2000AF2000AT

PEPCOMETER M

PEPCOMETER M

1200AF

FMR

1200AF

FMR

1200AF

FMR

1200AF

FMR

1200AF

FMR

1200AF

FMR

1200AF

FMR

1200AF

FMR

PQM PQM

2000A, 3PH, 3W, 13.8KVSWGR 3

50 51

50G 51G

PAF

67 86

AFD

50 51

50G 51G

PAF

67 86

AFD

50 51

50G 51G

PAF

67 86

AFD

50 51

50G 51G

PAF

67 86

AFD

50 51

50G 51G

PAF

67 86

AFD

50 51

50G 51G

PAF

67 86

AFD

50 51

50G 51G

PAF

67 86

AFD

50 51

50G 51G

PAF

67 86

AFD

DPR

87

PQMPQM PQM PQM PQM PQM PQM PQM

2000AF2000AT

2000AF2000AT

PEPCOMETER M

PEPCOMETER M

PEPCOMETER M

NG

4/0 CU

4

G3 G

3G

3

G3

G3

9 9

200N

200N

27

SUBSTATION RELAY

50 50G 51 51G 81

59 25 6786 27SUBSTATION RELAY

50 50G 51 51G 81

59 25 6786 27

SUBSTATION RELAY

50 50G 51 51G 81

59 25 6786 27

SUBSTATION RELAY

50 50G 51 51G 81

59 25 6786 27

SUBSTATION RELAY

50 50G 51 51G 81

59 25 6786 27

1

10

40 KAIC

1

10

40 KAIC

200:5 200:5 200:5 200:5400:5 300:5 400:5

2000:5 2000:5 2000:5 2000:5

2000:5 2000:5

200:5 200:5400:5 400:5100:5 100:5 300:5

400:5 400:5 200:5300:5300:5 100:5 200:5

52 52 52 52 52 52 52 52

52 52

52 52 52 52 52 52 52 52

52 52

52 52 52 52 52 52 52 52

52 52 1. ALL NEW COMPONENTS WILL BE DESIGNED IN ACCORDANCE

WITH THE NIH DRM AND PEPCO REQUIREMENTS.

2. REFER TO DRAWINGS E-601 AND E-602 FOR MORE INFORMATION.

GENERAL DRAWING NOTES:

PROVIDE NEW 2000A, 3PH, 3W, 13.8 KV SWITCHGEAR.

COORDINATE 2000A, 13.8 KV BUSWAY MODIFICATIONS ORREPLACEMENT WITH PEPCO.

PROVIDE NEW 13.8 KV FEEDERS TO NEW JUNCTION BARS INMANHOLES.

PROVIDE NEW 200A, 4P, 4W, 208Y/120V, SERVICE ENTRANCE RATEDATS. COORDINATE ANY ADDITIONAL REQUIREMENTS WITH PEPCO.

PROVIDE ONE SPARE 2000A MAIN BREAKER TO BE STORED IN THESWITCHGEAR ROOM FOLLOWING CONSTRUCTION.

PROVIDE NEW 200A, 3PH, 4W, 208Y/120V PANEL.

PROVIDE NEW BATTERY CHARGER WITH BEST BATTERY SELECTORAND NEW BATTERIES. COORDINATE REQUIREMENTS WITHSWITCHGEAR MANUFACTURER.

PROVIDE NEW 125V DC PANELBOARD. COORDINATE REQUIRMENTSWITH SWITCHGEAR MANUFACTURER.

COORDINATE FEEDER MODIFICATIONS WITH PEPCO.

BASIS OF DESIGN:SWITCHGEAR: SIEMENS GM-SGRELAYS: SEL-700 SERIESPQM: ELECTRO INDUSTRIES NEXUS 1500+

SPECIFIC DRAWING NOTES:1

2

3

4

5

6

7

8

9

10

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

OFFICE OFRESEARCH FACILITIES

PRO

JEC

TTI

TLE

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEAL

CO

NTR

ACTO

RS

BUIL

DIN

GPR

OJE

CT

DR

AWIN

GA/

E N

ame

and

LOG

O

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

11/2

/201

7 4:

01:2

2 PM

C:\U

sers

\mic

hael

.klin

e.ED

G2\

Doc

umen

ts\R

evit

2015

\160

18E-

R20

15_m

icha

el.k

line.

rvt

E-501

MK

MK

GC

Project Number

SIN

GLE

LIN

E D

IAG

RAM

- N

EW W

OR

K

36

N.T.S.1 SINGLE LINE DIAGRAM - NEW WORK

Page 17: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

RESERVETIE 1

1A

1B

V/T

PEPCOMETER

BAY

2 3A

3B

FEEDER2

FEEDER3

4A

4B

FEEDER4

FEEDER5

5A

5B

FEEDER6

MAIN 1

6A

6B

V/T

SWITCHGEAR 1

8 9A

9B

FEEDER7

EQUIPPEDSPACE

PEPCOMETER

BAY

SPARE

7A

7B

RESERVETIE 2

FEEDER11

FEEDER12

FEEDER13

FEEDER14

FEEDER15

10A

FEEDER16

FEEDER17

11

MAIN 2

12A

12B

13A

13B

14A

14B

15A

15B

16A

16B

17 18A

18B

PEPCOMETER

BAY

SPARE

PEPCOMETER

BAY

V/T

MAIN 3 EQUIPPEDSPACE

FEEDER18

FEEDER19

FEEDER20

FEEDER21

EQUIPPEDSPACE

SPARE

RESERVETIE 3

19A

19B

20 21A

21B

22A

22B

23A

23B

24A

24B

25A

25B

26

V/T

PEPCOMETER

BAY

27A

27B

PEPCOMETER

BAY

FEEDER27

V/T

SWITCHGEAR 2

SWITCHGEAR 3

914[36"]

914[36"]

914[36"]

914[36"]

914[36"]

914[36"]

914[36"]

914[36"]

914[36"]

2438[96"]

2502[98.5"]

914[36"]

914[36"]

914[36"]

914[36"]

914[36"]

914[36"]

914[36"]

914[36"]

914[36"]

2438[96"]

2502[98.5"]

914[36"]

914[36"]

914[36"]

914[36"]

914[36"]

914[36"]

914[36"]

914[36"]

914[36"]

2438[96"]

2502[98.5"]

V/T

FEEDER25

FEEDER26

FEEDER1

EQUIPPEDSPACE

EQUIPPEDSPACE

EQUIPPEDSPACE

BOD: SIEMENS

BOD: SIEMENS

BOD: SIEMENS

10B

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

OFFICE OFRESEARCH FACILITIES

PRO

JEC

TTI

TLE

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEAL

CO

NTR

ACTO

RS

BUIL

DIN

GPR

OJE

CT

DR

AWIN

GA/

E N

ame

and

LOG

O

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

11/2

/201

7 4:

01:2

4 PM

C:\U

sers

\mic

hael

.klin

e.ED

G2\

Doc

umen

ts\R

evit

2015

\160

18E-

R20

15_m

icha

el.k

line.

rvt

E-601

MK

MK

GC

Project Number

SWIT

CH

GEA

R E

LEVA

TIO

N -

NEW

WO

RK

37

N.T.S.1 SWITCHGEAR ELEVATION - NEW WORK

Page 18: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

OFFICE OFRESEARCH FACILITIES

PRO

JEC

TTI

TLE

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEAL

CO

NTR

ACTO

RS

BUIL

DIN

GPR

OJE

CT

DR

AWIN

GA/

E N

ame

and

LOG

O

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET 38 OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

11/2

/201

7 4:

01:2

4 PM

C:\U

sers

\mic

hael

.klin

e.ED

G2\

Doc

umen

ts\R

evit

2015

\160

18E-

R20

15_m

icha

el.k

line.

rvt

E-602

Designer

Author

Checker

Project Number

ELEC

TRIC

AL S

CH

EDU

LES

Page 19: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

BUILDING 17

EN-93

EN-101

EN-100

EN-96

EN-90

FEEDERS 2,7, 13, 17, 21,27

EN-102

FEEDERS 3, 12, 19

EN-92

FEEDERS14, 20

EN-88

FEEDERS 1,4, 11, 14, 18

EN-89

FEEDER 20

EN-99

FEEDER 14

EN-98

FEEDERS5, 6, 15, 16,25, 26

EN-94

EN-95

FEEDERS 1, 2,3, 4, 5, 6, 7

FEEDERS18, 19, 20,21, 25, 26,27

FEEDERS5, 6, 15,16, 25, 26

FEEDERS 2, 3, 7,11, 14, 15, 16, 18,20, 25, 26

FEEDERS 11, 12,13, 14, 15, 16, 17

FEEDERS 2, 3, 7,12, 13, 14, 17, 18,20, 25, 26

FEEDERS5, 6, 15, 16,25, 26

1

1

1

1

2

2

4

5

6

9

10

3

7

8

12

10

11

1. DRAWINGS ARE DIAGRAMMATIC. CONTRACTOR TO DETERMINEBEST DUCT BANK ROUTES AND WINDOW LOCATIONS IN THEFIELD.

2. REFER TO DRAWINGS E-002, E-604, AND E-605 FOR MOREINFORMATION.

3. U.O.N. ALL EXISTING DUCT BANKS TO REMAIN.

4. CONTRACTOR SHALL PROVIDE NEW FEEDER TAGS FOR ALLNEW FEEDERS IN EACH MANHOLE.

5. ALL NEW FEEDERS SHALL BE PROVIDED WITH A FULL LOOP OFSLACK CABLING WITHIN EACH MANHOLE. PROVIDE RACKING ASREQUIRED.

6. PROVIDE JUNCTION BARS AND DEAD BREAK ELBOWS FOR ALLREQUIRED FEEDER CONNECTIONS/TERMINATIONS WITHINMANHOLES. IF SPACE CONSTRAINTS WITHIN THE MANHOLEPREVENT THE INSTALLATION OF JUNCTION BARS AND DEADBREAK ELBOWS, THEY SHALL BE INSTALLED IN THE CLOSESTPRACTICAL MANHOLE INSTEAD. CONTRACTOR SHALL EXTENDNEW OR TEMPORARY FEEDERS AS REQUIRED TO ACCOMODATETHIS AT NO ADDITIONAL COST TO THE OWNER.

GENERAL DRAWING NOTES:

PROVIDE NEW 20-WAY DUCT BANK WITH 127 MM [5"] DUCTS.

CONTRACTOR SHALL LEAVE EXISTING DUCTS INTACT WHEREPOSSIBLE.

PROVIDE 3-POINT JUNCTION BARS FOR FEEDER 14 AND INTERCEPTEXISTING FEEDERS IN MANHOLE. PROVIDE 4-POINT JUNCTION BARSFOR FEEDER 20 AND INTERCEPT EXISTING FEEDERS IN MANHOLE.

PROVIDE 3-POINT JUNCTION BARS FOR FEEDERS 2 & 19 ANDINTERCEPT EXISTING FEEDERS IN MANHOLE. PROVIDE 4-POINTJUNCTION BARS FOR FEEDER 12 AND INTERCEPT EXISTINGFEEDERS IN MANHOLE.

PROVIDE 3-POINT JUNCTION BARS FOR FEEDERS 7, 13, 17, 21, & 27AND INTERCEPT EXISTING FEEDERS IN MANHOLE.

PROVIDE 4-POINT JUNCTION BARS FOR FEEDER 14 AND INTERCEPTEXISTING FEEDERS IN MANHOLE.

PROVIDE 3-POINT JUNCTION BARS FOR FEEDER 1 AND INTERCEPTEXISTING FEEDERS IN MANHOLE. PROVIDE 5-POINT JUNCTION BARSFOR FEEDERS 4, 11, & 18 AND INTERCEPT EXISTING FEEDERS INMANHOLE.

PROVIDE 3-POINT JUNCTION BARS FOR FEEDER 20 AND INTERCEPTEXISTING FEEDERS.

PROVIDE 5-POINT JUNCTION BARS FOR FEEDERS 5, 6, 15, 16, 25, & 26AND INTERCEPT EXISTING FEEDERS IN MANHOLE.

PROVIDE NEW FEEDERS IN EXISTING DUCTS.

PROVIDE NEW FEEDERS IN EXISTING DUCTS. FEEDER 20 WILL RUNFROM MANHOLE EN-93 TO MANHOLE EN-92, INTERCEPT THEEXISTING FEEDERS VIA JUNCTION BARS, AND RETURN TO MANHOLEEN-92.

PROVIDE NEW FEEDERS IN EXISTING DUCTS FOR FEEDERS 1, 4, 11,& 18.

SPECIFIC DRAWING NOTES:1

2

3

4

5

6

7

8

9

10

11

12

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

OFFICE OFRESEARCH FACILITIES

PRO

JEC

TTI

TLE

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEAL

CO

NTR

ACTO

RS

BUIL

DIN

GPR

OJE

CT

DR

AWIN

GA/

E N

ame

and

LOG

O

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET 39 OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

11/2

/201

7 4:

01:2

5 PM

C:\U

sers

\mic

hael

.klin

e.ED

G2\

Doc

umen

ts\R

evit

2015

\160

18E-

R20

15_m

icha

el.k

line.

rvt

E-603

Designer

Author

Checker

Project Number

MAN

HO

LE P

LAN

- N

EW W

OR

K

N.T.S.1 PARTIAL MANHOLE PLAN - NEW WORK

Page 20: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

3099 (10'2")3658 (12'0")

1829 (6'0")

NORTH

TO MHEN-93

TO MHEN-100

XXXX

XXS

XXX

FDR 26 (N)

FDR 25 (N)

FDR 25 (N)

FDR 26 (N)

FDR 18 (N)

FDR 18 (N)FDR 20 (N)

FDR 17 (N)

FDR 12 (N)FDR 13 (N)

FDR 14 (N)

FDR 2 (N)FDR 7 (N)

FDR 3 (N)

FDR 15 (N)

FDR 16 (N)

FDR 16 (N)

FDR 25 (N)

FDR 26 (N)

FDR 26 (N)

FDR 15 (N)

FDR 25 (N)FDR 20 (N)

FDR 14 (N)

FDR 2 (N)FDR 3 (N)

FDR 7 (N)

FDR 18 (N)

FDR 11 (N)

FDR 18 (N)

FDR 15 (N)

FDR 13 (N)

FDR 11 (N)

FDR 11 (N)

FDR 17 (N)

FDR 16 (N)FDR 16 (N)

FDR 11 (N)

FDR 14 (N)

FDR 15 (N)

FDR 12 (N)

FDR 27 (E)

3658 (12'0")

3150 (10'4")

1829 (6'0")

NORTH

TO MHEN-92

TO MHEN-102

TO MHEN-90

FDR 17 (E)

FDR 21 (E)

FDR 13 (E)

FDR 7 (E)FDR 2 (E)

SS

S S S

S S S S S S

SS

S

X X

X X

X X X X

X

XXXX

XXS

TO BLDG 17SWGR 3

TO MHEN-101

FDR 20 (N)FDR 21 (N)

FDR 27 (N)

FDR 26 (N)

FDR 26 (N)

FDR 18 (N)

FDR 25 (N)

FDR 25 (N)

FDR 18 (N)

FDR 3 (N)FDR 12 (N)

FDR 19 (N)

FDR 26 (N)

FDR 25 (N)

FDR 18 (N)

FDR 26 (N)

FDR 25 (N)FDR 18 (N)

FDR 2 (N)

FDR 7 (N)

FDR 17 (N)

FDR 20 (N)FDR 3 (N)

FDR 14 (N)

FDR 12 (N)FDR 13 (N)

FDR 19 (N)

FDR 20 (N)

FDR 14 (N)

3048 (10'0")

3048 (10'0")

1981 (6'6")

NORTH

S

SS

S S

S

SS

S S

S

S

S

S

S

S

S

SS

S

S

S

S

S

SS

S

SS

S S

FDR 3 (E)FDR 19 (E)

FDR 12 (E)

TO MHEN-103

TO UNKNOWN

FDR 12 (E)

TO MHMH-2

FDR 3 (N)

FDR 12 (N)

FDR 19 (N)

2438 (8'0")

1829 (6'0")

1524 (5'0")

S

TO BLDG21

TO MHEN-93

FDR 14 (E)

FDR 20 (E)

NORTH

FDR 14 (N)

FDR 20 (N)

1. DRAWINGS ARE DIAGRAMMATIC. CONTRACTOR TO DETERMINEBEST DUCT BANK ROUTES AND WINDOW LOCATIONS IN THEFIELD.

2. REFER TO DRAWINGS E-002, E-603, AND E-605 FOR MOREINFORMATION.

3. U.O.N. ALL EXISTING DUCT BANKS TO REMAIN.

4. CONTRACTOR SHALL PROVIDE NEW FEEDER TAGS FOR ALLNEW FEEDERS IN EACH MANHOLE.

5. ALL NEW FEEDERS SHALL BE PROVIDED WITH A FULL LOOP OFSLACK CABLING WITHIN EACH MANHOLE. PROVIDE RACKING ASREQUIRED.

6. PROVIDE JUNCTION BARS AND DEAD BREAK ELBOWS FOR ALLREQUIRED FEEDER CONNECTIONS/TERMINATIONS WITHINMANHOLES. IF SPACE CONSTRAINTS WITHIN THE MANHOLEPREVENT THE INSTALLATION OF JUNCTION BARS AND DEADBREAK ELBOWS, THEY SHALL BE INSTALLED IN THE CLOSESTPRACTICAL MANHOLE INSTEAD. CONTRACTOR SHALL EXTENDNEW OR TEMPORARY FEEDERS AS REQUIRED TO ACCOMODATETHIS AT NO ADDITIONAL COST TO THE OWNER.

GENERAL DRAWING NOTES:

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

OFFICE OFRESEARCH FACILITIES

PRO

JEC

TTI

TLE

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEAL

CO

NTR

ACTO

RS

BUIL

DIN

GPR

OJE

CT

DR

AWIN

GA/

E N

ame

and

LOG

O

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET 40 OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

11/2

/201

7 4:

01:2

6 PM

C:\U

sers

\mic

hael

.klin

e.ED

G2\

Doc

umen

ts\R

evit

2015

\160

18E-

R20

15_m

icha

el.k

line.

rvt

E-604

Designer

Author

Checker

Project Number

MAN

HO

LE F

OLD

OU

TS -

NEW

WO

RK

N.T.S.1 MANHOLE EN-101 - NEW WORKN.T.S.2 MANHOLE EN-93 - NEW WORK

N.T.S.3 MANHOLE EN-102 - NEW WORKN.T.S.4 MANHOLE EN-92 - NEW WORK

Page 21: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

2438 (8'0")

3658 (12'0")

2438 (8'0")

NORTH

TO MHEN-98

FDR 16 (E)

FDR 6 (E)FDR 6 (E)

FDR 16 (E)FDR 26 (E)

FDR 26 (E)

FDR 25 (E)FDR 5 (E)

FDR 15 (E)

FDR 15 (E)

FDR 25 (E)FDR 5 (E)

S S S S

S

S

XXTO MHEN-96

FDR 6 (N)

FDR 5 (N)FDR 5 (N)

FDR 6 (N)

FDR 25 (N)

FDR 16 (N)FDR 16 (N)

FDR 25 (N)FDR 26 (N)

FDR 26 (N)

FDR 15 (N)FDR 15 (N)

1829 (6'0")

3658 (12'0")3048 (10'0")

TO MHEN-101

TO T-69

TO MHEN-95

NORTH

S S

S

S S

SS

S

SS

FDR 14 (E)

FDR 14 (E)

TO MHEN-101

TO MHEN-96

FDR 15 (N)

FDR 5 (N)

FDR 6 (N)

FDR 15 (N)

FDR 5 (N)FDR 6 (N)

FDR 16 (N)FDR 16 (N)

FDR 26 (N)

FDR 26 (N)FDR 25 (N)

FDR 25 (N)

FDR 26 (N)

FDR 26 (N)FDR 25 (N)

FDR 25 (N)FDR 15 (N)

FDR 5 (N)

FDR 5 (N)

FDR 15 (N)

FDR 6 (N)

FDR 6 (N)

FDR 16 (N)

FDR 16 (N)

3429 (11'3") 3658 (12'0")

1829 (6'0")

NORTH

TO MH EN-88& MH EN-89

TO MHEN-99

FDR 14 (E)

X

X

X

X X X

X X X

XX

X

XX

FDR 14 (E)

TO MH EN-101

TO MH EN-101 TO BLDG 17 SWGR 1

FDR 5 (N)

FDR 15 (N)

FDR 6 (N)FDR 5 (N)

FDR 16 (N)FDR 16 (N)

FDR 25 (N)

FDR 6 (N)

FDR 26 (N)

FDR 26 (N)FDR 25 (N)

FDR 15 (N)

FDR 16 (N)

FDR 15 (N)

FDR 15 (N)

FDR 26 (N)

FDR 25 (N)

FDR 25 (N)

FDR 16 (N)

FDR 26 (N)

FDR 6 (N)

FDR 5 (N)

FDR 6 (N)

FDR 2 (N)

FDR 14 (N)

FDR 20 (N)

FDR 2 (N)

FDR 11 (N)

FDR 7 (N)

FDR 13 (N)

FDR 18 (N)FDR 11 (N)

FDR 18 (N)FDR 4 (N)

FDR 7 (N)FDR 1 (N)FDR 5 (N)

FDR 3 (N)

FDR 4 (N)

FDR 18 (N)FDR 18 (N)

FDR 1 (N)

FDR 11 (N)FDR 20 (N)

FDR 4 (N)

FDR 4 (N)

FDR 11 (N)FDR 11 (E)

2438 (8'0")

1524 (5'0")

2667 (8'8")

X

XS

X

S

S

S

X

XX S

FDR 14 (E)

S

FDR 11 (E)

FDR 4 (E)FDR 4 (E)

FDR 18 (E)

FDR 1 (E)

FDR 25 (E)

FDR 18 (E)

FDR 14 (E)

TO MHEN-100

TO MHEN-87

NORTH

FDR 4 (N)

FDR 1 (N)

FDR 11 (N)

FDR 18 (N)

FDR 4 (N)

FDR 11 (N)

FDR 18 (N)

FDR 1 (N)

2438 (8'0")

1829 (6'0")

1524 (5'0")

X

X

X

X X S X

S S

TO MHEN-100

TO MHEN-78

FDR 20 (E)

TO MHEN-87

NORTH

FDR 20 (N)

1. DRAWINGS ARE DIAGRAMMATIC. CONTRACTOR TO DETERMINEBEST DUCT BANK ROUTES AND WINDOW LOCATIONS IN THEFIELD.

2. REFER TO DRAWINGS E-002, E-603, AND E-604 FOR MOREINFORMATION.

3. U.O.N. ALL EXISTING DUCT BANKS TO REMAIN.

4. CONTRACTOR SHALL PROVIDE NEW FEEDER TAGS FOR ALLNEW FEEDERS IN EACH MANHOLE.

5. ALL NEW FEEDERS SHALL BE PROVIDED WITH A FULL LOOP OFSLACK CABLING WITHIN EACH MANHOLE. PROVIDE RACKING ASREQUIRED.

6. PROVIDE JUNCTION BARS AND DEAD BREAK ELBOWS FOR ALLREQUIRED FEEDER CONNECTIONS/TERMINATIONS WITHINMANHOLES. IF SPACE CONSTRAINTS WITHIN THE MANHOLEPREVENT THE INSTALLATION OF JUNCTION BARS AND DEADBREAK ELBOWS, THEY SHALL BE INSTALLED IN THE CLOSESTPRACTICAL MANHOLE INSTEAD. CONTRACTOR SHALL EXTENDNEW OR TEMPORARY FEEDERS AS REQUIRED TO ACCOMODATETHIS AT NO ADDITIONAL COST TO THE OWNER.

GENERAL DRAWING NOTES:

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

OFFICE OFRESEARCH FACILITIES

PRO

JEC

TTI

TLE

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEAL

CO

NTR

ACTO

RS

BUIL

DIN

GPR

OJE

CT

DR

AWIN

GA/

E N

ame

and

LOG

O

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET 41 OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

11/2

/201

7 4:

01:2

7 PM

C:\U

sers

\mic

hael

.klin

e.ED

G2\

Doc

umen

ts\R

evit

2015

\160

18E-

R20

15_m

icha

el.k

line.

rvt

E-605

Designer

Author

Checker

Project Number

MAN

HO

LE F

OLD

OU

TS -

NEW

WO

RK

N.T.S.1 MANHOLE EN-96 - NEW WORKN.T.S.2 MANHOLE EN-99 - NEW WORK

N.T.S.3 MANHOLE EN-100 - NEW WORKN.T.S.4 MANHOLE EN-88 - NEW WORK

N.T.S.5 MANHOLE EN-89 -NEW WORK

Page 22: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

~

422

3 3 3

1

1

1

1

1

1

2

1A

1B

RELAY

CB

TIE 1

PQM

2

PEPCOMETER

BAY

3A

3B

RELAY

FEEDER 1

PQMCB

RELAY

FEEDER 2

PQMCB

4A

4B

RELAY

FEEDER 3

PQMCB

RELAY

FEEDER 4

PQMCB

5A

5B

RELAY

FEEDER 5

PQMCB

RELAY

FEEDER 6

PQMCB

6A

6B

RELAY

FEEDER 7

PQMCB

RELAY

SPACE

PQMCB

7A

7B

RELAY

SPACE

PQMCB

RELAY

SPARE

PQMCB

8

PEPCOMETER

BAY

9A

9B

RELAY

CB

MAIN 1

PQM

10A

10B

RELAY

CB

TIE 2

PQM

11

PEPCOMETER

BAY

12A

12B

RELAY

FEEDER 11

PQMCB

RELAY

FEEDER 12

PQMCB

13A

13B

RELAY

FEEDER 13

PQMCB

RELAY

FEEDER 14

PQMCB

14A

14B

RELAY

FEEDER 15

PQMCB

RELAY

FEEDER 16

PQMCB

15A

15B

RELAY

FEEDER 17

PQMCB

RELAY

SPACE

PQMCB

16A

16B

RELAY

SPACE

PQMCB

RELAY

SPARE

PQMCB

17

PEPCOMETER

BAY

18A

18B

RELAY

CB

MAIN 2

PQM

19A

19B

RELAY

CB

MAIN 3

PQM

RS485P-PANEL

20

PEPCOMETER

BAY

21A

21B

RELAY

FEEDER 18

PQMCB

RELAY

FEEDER 19

PQMCB

22A

22B

RELAY

FEEDER 20

PQMCB

RELAY

FEEDER 21

PQMCB

23A

23B

RELAY

SPACE

PQMCB

RELAY

SPARE

PQMCB

24A

24B

RELAY

SPACE

PQMCB

RELAY

FEEDER 25

PQMCB

25A

25B

RELAY

FEEDER 26

PQMCB

RELAY

FEEDER 27

PQMCB

26

PEPCOMETER

BAY

27A

27B

RELAY

CB

TIE 3

PQM

IGIN CABINET

BATTERYCHARGER

TO NIHCOMM.CLOSET

TIE 1PQM/RLY

FDR 1PQM/RLY

FDR 2PQM/RLY

FDR 3PQM/RLY

FDR 4PQM/RLY

FDR 5PQM/RLY

FDR 6PQM/RLY

FDR 7PQM/RLY

SPACEPQM/RLY

SPACEPQM/RLY

SPAREPQM/RLY

MAIN 1PQM/RLY

RS485 PATCH PANEL

RS485 PATCH PANEL

IGIN CABINET

SWITCHGEAR 1

TIE 2PQM/RLY

FDR 11PQM/RLY

FDR 12PQM/RLY

FDR 13PQM/RLY

FDR 14PQM/RLY

FDR 15PQM/RLY

FDR 16PQM/RLY

FDR 17PQM/RLY

SPACEPQM/RLY

SPACEPQM/RLY

SPAREPQM/RLY

MAIN 2PQM/RLY

SWITCHGEAR 2

MAIN 3PQM/RLY

FDR 18PQM/RLY

FDR 19PQM/RLY

FDR 20PQM/RLY

FDR 21PQM/RLY

SPACEPQM/RLY

SPAREPQM/RLY

SPACEPQM/RLY

FDR 25PQM/RLY

FDR 26PQM/RLY

FDR 27PQM/RLY

TIE 3PQM/RLY

SWITCHGEAR 3

RS485 PATCH PANEL RS485 PATCH PANEL

IGIN CABINET IGIN CABINET

RS485P-PANEL

RS485P-PANEL

RS485 PATCH PANEL RS485 PATCH PANEL

1. ALL CABLING, TERMINATIONS, AND PATCH PANELS INTERNAL TOTHE SWITCHGEAR SHALL BE SUPPLIED AND INSTALLED BY THESWITCHGEAR VENDOR.

2. THE RS485 CABLING SHALL BE PROVIDED FOR THE DNPPROTOCOL CONNECTIONS FROM EACH IED (RELAYS ANDMETERS) TO THE PATCH PANELS LOCATED WITHIN THESWITCHGEAR THEN TO THE PATCH PANELS PROVIDED WITHINTHE IGIN CABINET.

GENERAL DRAWING NOTES:

PROVIDE 2 SETS RS485 (TWISTED PAIR) CABLE AND TERMINATIONS.

PROVIDE 102 MM (4") CONDUIT.

PROVIDE A PATCH PANEL AND TERMINATE ALL RS485 WITHIN EACHSWITCHGEAR LINEUP.

SPECIFIC DRAWING NOTES:1

2

3

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

OFFICE OFRESEARCH FACILITIES

PRO

JEC

TTI

TLE

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEAL

CO

NTR

ACTO

RS

BUIL

DIN

GPR

OJE

CT

DR

AWIN

GA/

E N

ame

and

LOG

O

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET 42 OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

11/2

/201

7 4:

01:2

7 PM

C:\U

sers

\mic

hael

.klin

e.ED

G2\

Doc

umen

ts\R

evit

2015

\160

18E-

R20

15_m

icha

el.k

line.

rvt

E-606

Designer

Author

Checker

Project Number

SCAD

A PL

AN -

NEW

WO

RK

Page 23: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

191 [71_2"]

146 [53_4"]

146 [53_4"]

191 [71_2"]

191 [71_2"]

152 [6"]

762 [30"]MAXIMUM

191[71

2"]191[71

2"]191[71

2"]146[53

4"]146[53

4"]191[71

2"]

GRADE

UNDISTURBEDEARTH

PLASTIC CAUTION TAPE ALONGTHE ENTIRE LENGTH OF DUCTBANK.

CONCRETE

127 [5"]CONDUIT(TYPICAL)

51 [2"] MINIMUMSTANDOFF

8 [9/32"] HOLES FOR LUG CONNECTIONS

6.5 [1/4"] COPPERGROUND BUS

THAN 203 [8"]

GROUND BUS - ELEVATION

GROUND BUS - PLAN VIEW

STANDOFF

WALL

GROUND BUS

NO LESS

ISOMETRIC VIEW

OM 51 [2"] CENTERS (TYPICAL FOR 2)

11 [7/16"]

79 [3 1/8"]

38 [1 1/2"]

38 [1 1/2"]

51 [2"] 76 [3"]

51 [2"]

101 [4"]

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

OFFICE OFRESEARCH FACILITIES

PRO

JEC

TTI

TLE

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEAL

CO

NTR

ACTO

RS

BUIL

DIN

GPR

OJE

CT

DR

AWIN

GA/

E N

ame

and

LOG

O

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET 43 OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

11/2

/201

7 4:

01:2

8 PM

C:\U

sers

\mic

hael

.klin

e.ED

G2\

Doc

umen

ts\R

evit

2015

\160

18E-

R20

15_m

icha

el.k

line.

rvt

E-701

Designer

Author

Checker

Project Number

ELEC

TRIC

AL D

ETAI

LS

N.T.S.1 20-WAY DUCT BANK DETAILN.T.S.2 GROUND BAR

Page 24: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

1. THIS DRAWING SET PROVIDES APPROXIMATE EQUIPMENT LOCATIONS, FIELD VERIFY AND COORDINATE CAMERA LOCATION WITH VIEWING OBJECTIVE. LOCATEAS APPLICABLE. NOTIFY CONTRACTING OFFICER OF ANY DEVIATIONS GREATER THAN 610mm [24 INCHES].

2. PROMPTLY NOTIFY CONTRACTING OFFICER PRIOR TO INSTALLATION OF WORK IF MOUNTING LOCATIONS NOTED ON THE DRAWINGS ARE OBSTRUCTED AND/ORIF ANY MOUNTING CONFLICTS OR PROBLEMS ARE DISCOVERED. DO NOT PROCEED WITHOUT CONTRACTING OFFICER'S WRITTEN AUTHORIZATION.

3. COORDINATE REQUIREMENTS FOR RELEASE OF SECURITY SYSTEM CONTROLLED DOORS WITH FIRE ALARM SYSTEM AND BUILDING EMERGENCY EVACUATIONALARM SYSTEM. SECURITY SYSTEM SHALL NOT VIOLATE LIFE SAFETY REQUIREMENTS. WHERE REQUIRED, PROVIDE MEANS FOR FIRE ALARM/BUILDINGEMERGENCY EVACUATION SYSTEM TO AUTOMATICALLY UNLOCK SECURITY MANAGEMENT SYSTEM CONTROLLED DOORS WITHOUT SECURITY MANAGEMENTSYSTEM ACTION.

4. REFER TO ARCHITECT'S APPROVED DOOR HARDWARE SCHEDULE FOR SECURITY MANAGEMENT SYSTEM CONTROLLED LOCKS AND DOOR HARDWARE SET.COORDINATE WITH SECURITY DRAWINGS. PROVIDE UL APPROVED POWER SUPPLIES AS REQUIRED.

5. UNLESS NOTED OTHERWISE EACH MONITORED INPUT DEVICE OF THE SECURITY MANAGEMENT SYSTEM SHALL BE CONSIDERED AN INDIVIDUAL ZONE ANDSHALL BE ELECTRICALLY SUPERVISED AND HOMERUN TO ITS ASSOCIATED SYSTEM CONNECTION. TAMPER SWITCH INPUTS SHALL BE CONSIDERED ADDITIONALZONES SEPARATE FROM OTHER ALARM SIGNAL INPUTS. END-OF-LINE SUPERVISION DEVICE SHALL BE INSTALLED AT THE FIELD DEVICE END.

6. ELECTRICAL CONTRACTOR WILL PROVIDE PRIMARY 120 VAC INPUT POWER FOR POWER SUPPLIES AND OTHER SYSTEM COMPONENTS. COORDINATE POWERREQUIREMENTS WITH ELECTRICAL CONTRACTOR. COORDINATE FINAL LOCATIONS OF POWER CIRCUITS FOR SECURITY SYSTEM DEVICES WITH OTHER TRADES.SECURITY EQUIPMENT SHALL BE SUPPLIED FROM DEDICATED CIRCUIT BREAKERS CONNECTED TO THE BUILDING'S EMERGENCY DISTRIBUTION SYSTEM WITHLOCAL BATTERY UNITS AS INDICATED. REFER TO ELECTRICAL DRAWINGS FOR LOCATION OF POWER CIRCUITS.

7. WIRING SYSTEMS SHALL BE CONSISTENTLY COLOR CODED AND TAGGED. REFER TO SPECIFICATIONS FOR DETAILED REQUIREMENTS.

8. ALL FIELD DEVICES SHALL BE STUBBED UP IN MINIMUM 21mm [3/4"] CONDUIT TO A MINIMUM 100mm x 100mm x 54mm [4" x 4" x 2-1/8"] FIELD DEVICE JUNCTION BOXIN A SECURE, ELECTRONICALLY PROTECTED AREA NEAR CEILING.

9. PROVIDE A PULL CORD CAPABLE TO OF MEETING, AT A MINIMUM, THE MAXIMUM CABLE PULL TENSIONS AS IDENTIFIED THE 27 11 00 SPECIFICATION. PROVIDEIDENTIFICATION AT EACH END, IN ALL CONDUIT.

10. FIRESTOP ALL STRUCTURE PENETRATIONS WITH FIRESTOPPING MATERIAL EQUAL TO OR GREATER THAN THAT OF PENETRATED STRUCTURE. INSTALLFIRESTOPPING MATERIAL AFTER COMPLETE INSTALLATION AND TESTING OF CABLING. USE ONLY LISTED FIRESTOPPING MATERIAL IN ACCORDANCE WITH UL,NFPA, AND OTHER AHJ.

11. THE DRAWINGS INDICATE THE GENERAL LOCATION OF EQUIPMENT, CABLE PATHWAYS, DEVICE TYPES AND CONFIGURATIONS. MINOR VARIATIONS FROM THEDETAILS MAY OCCUR DUE TO FIELD CONDITIONS, ALTHOUGH THE DRAWINGS DO NOT NECESSARILY DICTATE THE ACTUAL ROUTES OF CONDUITS, LOCATIONOF EQUIPMENT AND DEVICES, AND OTHER SUPPORTING ITEMS, THEY SHALL BE FOLLOWED AS CLOSELY AS POSSIBLE TO THE DESIGN IN THIS DOCUMENT. ITWILL BE THE INSTALLING CONTRACTOR'S RESPONSIBILITY TO COORDINATE THE INSTALLATION OF ALL RELATED ITEMS WITH ALL AHJ AND CONTRACTORSWORKING THIS PROJECT.

12. THESE DRAWINGS ARE PREPARED AND COORDINATED WITH THE PROJECT SPECIFICATIONS. TOGETHER THESE DOCUMENTS FORM THE CONTRACTDOCUMENTS. ANYTHING MENTIONED IN THE SPECIFICATIONS AND NOT SHOWN IN THE DRAWINGS, OR SHOWN IN THE DRAWINGS AND NOT MENTIONED IN THESPECIFICATIONS, SHALL BE OF LIKE EFFECT AS IF SHOWN AND MENTIONED IN BOTH. IN CASE OF DIFFERENCES BETWEEN THE DRAWINGS AND THESPECIFICATIONS, THE STRICTER PROVISION AS DETERMINED BY THE CONTRACTING OFFICE SHALL GOVERN. OMISSIONS FROM THE DRAWINGS ORSPECIFICATIONS, OR THE INCORRECT DESCRIPTION OF DETAILS OF WORK WHICH ARE EVIDENTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGSAND SPECIFICATIONS, OR WHICH ARE CUSTOMARILY PERFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED ORINCORRECTLY DESCRIBED DETAIL OF THE WORK. RATHER, THE WORK SHALL BE PERFORMED AS IF THE DRAWINGS HAVE BEEN VERIFIED, CHECKED ANDCOORDINATED WITH SHOP DRAWINGS AND SAMPLES OF THE WORK AND OF THE SPECIFICATIONS.

13. CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUITS, DEVICE BOXES, JUNCTION BOXES, PANELS AND ASSOCIATED DEVICES, AND REQUIRED SLEEVESFOR WALL, FLOOR AND CEILING PENETRATIONS FOR A COMPLETE INSTALLATION.

14. CONTRACTOR TO MAINTAIN A 305mm [12"] MINIMUM SPACING BETWEEN CABLES AND SOURCES OF EMI, SUCH AS FLUORESCENT LIGHTS OR UNSHIELDEDPOWER LINES.

15. 120 VAC INPUT POWER CONDUCTORS SHALL NOT BE INSTALLED IN THE SAME CONDUIT AS LOW VOLTAGE VIDEO, CONTROL, DC POWER OR ANY OTHER LOWVOLTAGE CABLES. ELECTRICAL CONTRACTOR TO ENSURE PROPER SEPARATION OF CLASS 1, CLASS 2, AND CLASS 3 PER NEC 725-54 (D) AND/OR AHJ.

16. CONTRACTOR SHALL INSTALL APPROPRIATELY SIZED CONDUIT IAW STANDARD ANSI/TIA-569-B, "PATHWAYS AND SPACES AND THE NATIONAL ELECTRIC CODE(NEC)." ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL BACK BOXES, PULL-BOXES, JUNCTION BOXES AND CONDUIT INSTALLATION. MINIMUM SIZECONDUIT SHALL NOT BE LESS THAN 21mm [3/4"]. MAXIMUM CONDUIT FILL RATIO SHALL NOT BE MORE THAN 40%.

17. ALL INSTALLED CABLE AND COMPONENTS SHALL MEET THE WARRANTY REQUIREMENTS AS NOTED IN THE SPECIFICATIONS. THE CONTRACTOR IS REQUIREDTO BE A CERTIFIED STRUCTURED CABLING INSTALLER FOR THE TELECOMMUNICATIONS SYSTEM PROVIDED.

18. TELECOMMUNICATION INSTALLATION WORK SHALL FOLLOW ANSI, BICSI, EIA/TIA STANDARDS, NEC, AND OTHER APPLICABLE STANDARDS AND CODES.

19. NO USE OF STAPLES FOR CABLE ROUTING OR MOUNTING WILL BE PERMITTED.

20. IN ALL AREAS, PROTECT CABLE FROM TENSION, COMPRESSION, TORSION, BENDING, SQUEEZING AND VIBRATION. DO NOT PULL CABLES IMPROPERLY OREXCEED THE MANUFACTURERS TENSILE RATING.

T

B

SYMBOLS: GENERAL NOTES:CONDUIT ROUTE, SIZE AS NOTED

A-C PLYWOOD BACKBOARD TREATED WITH FIRE-RETARDENTPAINT. 2440mm [8'] HIGH MOUNTED 150mm [6"] AFF.

CEILING MOUNTED CAMERA WITH VARI-FOCAL LENS. REFERTO T-503 DETAIL 3 FOR TYPICAL INSTALLATION DETAIL.

CARD ACCESS READER. REFER TO T-501 AND T-505 FORTYPICAL INSTALLATION DETAIL.MOUNTING HEIGHT 1220mm [48"] AFF.

T: 1 = ONE FORM FACTOR AUTHENTICATION 2 = TWO FORM FACTOR AUTHENTICATION

WALL PHONE OUTLET EXISTING LOCATION.

WALL DATA OUTLET EXISTING LOCATION.

ABBREVIATIONS:% PERCENT& ANDA/V AUDIO VISUALAC ALTERNATING CURRENTACP ACCESS CONTROL PANELACS ACCESS CONTROL SYSTEMAFF ABOVE FINISH FLOORAHJ AUTHORITY HAVING JURISDICTIONALA ALARMANSI AMERICAN NATION STANDARD INSTITUTEAUX AUXILIARYAWG AMERICAN WIRE GAUGEBET BUILDING ENTRANCE TERMINALBICSI BUILDING INDUSTRY CONSULTING SERVICES INTERNATIONALBMS BALANCED MAGNETIC SWITCHC CONDUITCAT CATEGORYCAT3 CATEGORY 3CAT6 CATEGORY 6CB CIRCUIT BREAKERCCTV CLOSED CIRCUIT TELEVISIONCIT CENTER FOR INFORMATION TECHNOLOGYCLG CEILINGCOAX COAXIAL CABLECODEC ODER/DECOVERCONC CONCRETECONTR CONTRACTORCPS CAMERA POWER SUPPLYCPU CENTRAL PROCESSING UNITCR CARD READERD DATAD/A DIGITAL TO ANALOGdB DECIBELDC DIRECT CURRENTDIA DIAMETERDIST DISTRIBUTIONDPS DOOR POSITION SWITCHDPSM DIVISION OF PHYSICAL SECURITY MANAGEMENTDRI DOOR READER INTERFACEDS DOOR STRIKEDTL DETAILDWG DRAWINGEA EACHEIA ELECTRONIC INDUSTRIES ALLIANCEELEC ELECTRICELEV ELEVATIONEMI ELECTROMAGNETIC INTERFERENCEEMT ELECTRICAL METALLIC TUBINGENG ENGINEEREQP EQUIPMENTER EQUIPMENT ROOMES ELECTRIC STRIKEEXST EXISTINGEXT EXTERIORFO FIBER OPTICFPC FIBER OPTIC CABLEFPP FIBER OPTIC PATCH PANELGbps GIGA BITS PER SECONDSGFGI GOVERNMENT FURNISHED GOVERNMENT INSTALLEDGND GROUNDHH HANDHOLEHRZ HORIZONTALHSS HIGH SECURITY SWITCHHz HERTZIAW IN ACCORDANCE WITHIDS INTRUSION DETECTION SYSTEMIEEE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERSINL INTERLOCKIR INFRAREDJB JUNCTION BOXKbps KILO BITS PER SECONDKHz KILOHERTZKP KEYPAD ASSEMBLYLAN LOCAL AREA NETWORKLCD LIQUID CRYSTAL DISPLAYLED LIGHT EMITTING DIODELPS LOCK POWER SUPPLYMAX MAXIMUMMbps MEGA BITS PER SECONDMHz MEGAHERTZMH MAINTENANCE HOLEMIN MINIMUMMISC MISCELLANEOUSMM MULTI-MODEmm MILLIMETERMTD MOUNTEDMS MAGNETIC SWITCHMUX MULTIPLEXORN/A NOT APPLICABLEN NORTHNEC NATIONAL ELECTRIC CODENFPA NATIONAL FIRE AND PROTECTION AGENCYNAG NEGATIVENIC NOT IN CONTRACTNIH NATIONAL INSTITUTE OF HEALTHNPT NATIONAL PIPE THREADNTS NOT TO SCALEOC ON CENTEROD OUTSIDE DIAMETEROPT OPTICALOSP OUTSIDE PLANTPC PERSONAL COMPUTERPIN PERSONAL IDENTIFICATION NUMBERPNL PANELPOS POSITIVEPP PATCH PANELPR PAIRPVC POLYVINYL CHLORIDEPWR POWERQTY QUANTITYRCDD REGISTERED COMMUNICATIONS DISTRIBUTION DESIGNERREF REFERENCEREQ REQUIREDREX REQUEST TO EXITRF RADIO FREQUENCYRM ROOMRU RACK UNITRX RECEIVER/RECEIVERSM SINGLE-MODESMS SECURITY MANAGEMENT SYSTEMSOC SECURITY OPERATIONS CENTERSQ SQUARESS STAINLESS STEELSTP SHIELD TWISTED PAIRSTR STRAMDSW NETWORK SWITCHSYS SYSTEMTBB TELECOMMUNICATIONS BONDING BACKBONETEL TELEPHONETELECOM TELECOMMUNICATIONSTERM TERMINATIONSTIA TELECOMMUNICATIONS INDUSTRIES ASSOCIATIONTGB TELECOMMUNICATIONS GROUNDING BUSBARTMGB TELECOMMUNICATIONS MAIN GROUNDING BUSBARTR TELECOMMUNICATIONS ROOMTX TRANSMIT/TRANSMITTERTx Rx TRANSCEIVERTYP TYPICALUL UNDERWRITERS LABORATORIESUON UNLESS OTHERWISE NOTEDUPS UNINTERRUPTIBLE POWER SUPPLYUTP UNSHIELDED TWISTED PAIRWAP WIRELESS ACCESS POINTWP WEATHERPROOF

BALANCED MAGNETIC AUTOMATIC MONITORING SWITCH,SURFACE MOUNT.

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

OFFICE OFRESEARCH FACILITIES

PR

OJE

CT

TITL

E

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEA

LC

ON

TRAC

TOR

SB

UIL

DIN

GP

RO

JEC

TD

RAW

ING

A/E

Nam

e an

d LO

GO

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

11/2

/201

7 1:

51:5

9 PM

L:\D

CS\

Proj

ects

\BD

L\60

5044

85_S

wtc

hgrU

pg\9

00-W

ork\

910-

CAD

\05-

MO

DEL

S\N

IH_S

WG

R-T

ELEC

OM

v20

15.rv

t

T-100

PR

PR

RW

Project Number

GEN

ERAL

NO

TES

AND

SYM

BOLS

44

Page 25: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

DN

J

J

J

EXISTING WALL MOUNTED TELEPHONE. TELEPHONE AND CABLING TOREMAIN IN PLACE.

EXISTING WALL MOUNTED TELEPHONE PUNCH DOWN BLOCK. PUNCH DOWNBLOCK AND CABLING TO REMAIN IN PLACE.

EXISTING FIBER OPTIC PATCH PANEL ENCLOSURE WITH MULTIMODE ANDSINGLE MODE FIBER OPTIC CABLING WITH ST TYPE CONNECTORS. PATCHPANEL AND CABLING TO REMAIN IN PLACE.

CONTRACTOR TO VERIFY WITH NIH CIT, THAT EXISTING INCOMING FIBER ISUSABLE FOR DATA NETWORK AND THAT THERE IS SUFFICIENT AMOUNT OFFIBER FOR DATA NETWORK REQUIREMENTS.

EXISTING SUPERVISORY PANEL. SUPERVISORY PANEL IS SCHEDULED TO BEREPLACED IN KIND BY ELECTRICAL CONTRACTOR. REFER TO ELECTRICALDRAWINGS. BEFORE REPLACEMENT OF PANEL, DISCONNECT FIBER OPTICCABLING FROM PATCH PANEL AND COIL IN PLACE. PROVIDE A NEW PATCHPANEL AFTER CONSTRUCTION, REPULL AND TERMINATE FIBER AS BEFORE INNEW PATCH PANEL.

EXISTING INTERFACE PANEL (RTU-NIH-TB). REFER TO ELECTRICAL DRAWINGSFOR DISPOSITION OF SUPERVISORY PANEL.

NEW SCADA ENCLOSURE PROVIDED BY ELECTRICAL CONTRACTOR.PROVIDE 2 STRANDS FIBER OPTIC CABLE FROM THE EXISTING FIBER PATCHPANEL TO THE NEW SCADA ENCLOSURE. RUN NEW FIBER IN EMT CONDUITAND TERMINATE FIBER CABLING WITH ST CONNECTORS AT THE EXISTINGFIBER PATCH PANEL. COORDINATE FIBER TYPE AND PATCH PANELTERMINATION WITH NIH CIT.

EXISTING SCADA ENCLOSURE. REFER TO ELECTRICAL DRAWINGS FORDISPOSITION. PROVIDE 2 STRANDS OF MULTIMODE FIBER OPTIC CABLE FROMEXISTING FIBER OPTIC PATCH PANEL TO THE EXISTING SCADA ENCLOSUREAND RUN FIBER CABLING IN EMT.

PROVIDE AND INSTALL CEILING MOUNTED FIXED DOME CAMERA FOR VIEWINGOF FRONT DOOR. COORDINATE CAMERA HEIGHT AND LOCATION WITHEXISTING CEILING EQUIPMENT. REFER TO T-501, DETAIL 3.

PROVIDE A 610mm x 406mm x 168mm (24"H x 16"W x 6.6"D) NEMA 1 TYPEENCLOSURE WITH HINGED COVER AND LOCK FOR SECURITY EQUIPMENT.

1" CONDUIT. FIELD VERIFY ROUTE.

PROVIDE A 660mm x 660mm x 216mm DEEP (26" x 26" x 8.5"D) WALL MOUNTEDTHINLINE TELCO 4 RACK UNIT CABINET (CHATSWORTH 13050-112 ORAPPROVED EQUAL) FOR A NIH CIT PROVIDED PoE NETWORK SWITCH.

DOUBLE GANG ELECTRICAL BOX FOR GFGI WAP. SPACE ELECTRICAL BOXES10m APART.

305mm x 305mm x 153mm (12" x 12" x 6") JUNCTION BOX.

53mm CONDUIT.

KEYED NOTES:

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

1. SEE SHEET T-100 FOR SYMBOLS.2. ALL NEW TELECOMMUNICATIONS AND SECURITY CABLING SHALL RUN

IN EMT CONDUIT OR RACEWAY AND NOT BE EXPOSED.3. EXISTING EXPOSED CABLING SHALL BE RUN IN APPROVED PATHWAY.

GENERAL NOTES:

1

2

3

4

5

6

7

A

SWITCHGEAR

FIRE PUMP (NIC)

TOILET (NIC)

B B

B B

2

EXISTING CEILINGMOUNTED HEATER

2T-101

EXISTING CEILINGMOUNTED HEATER

1T-501

2T-501

12

SWITCHGEAR LEVEL[1'-8"]508

GRADE LEVEL[0'-0 1/2"]8

AIR DUCT

HEATER

[4' -

6"]

1372

[4' -

6"]

1372

SWITCHGEAR

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

OFFICE OFRESEARCH FACILITIES

PR

OJE

CT

TITL

E

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEA

LC

ON

TRAC

TOR

SB

UIL

DIN

GP

RO

JEC

TD

RAW

ING

A/E

Nam

e an

d LO

GO

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

BUILDING 17

BUILDING 21

11/2

/201

7 1:

52:0

4 PM

L:\D

CS\

Proj

ects

\BD

L\60

5044

85_S

wtc

hgrU

pg\9

00-W

ork\

910-

CAD

\05-

MO

DEL

S\N

IH_S

WG

R-T

ELEC

OM

v20

15.rv

t

T-101

PR

PR

RW

Project Number

TELE

CO

M F

LOO

R P

LAN

45

0 50002500

1:100

1 : 1001 SWITCHGEAR LEVEL FLOOR PLAN

1

1

2

3

6

5

N

8

9

10

10

0 25001250

1:50

7

4

1 : 502 EAST WALL ELEVATION

98 73

12

11

13

13

13

12

13

14

15

Page 26: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

1220

[48"

]

1372

[54"

]

CEILING LINE

FLOOR LINE

SECURE SIDE

NON-SECURE SIDE

CEILING LINE

FLOOR LINE

SECURE SIDE

NON-SECURE SIDE

NC C NO NC C NOAC FAILBAT FAIL

TRIGGERACDC AC1

EOLNOGNDSUPERVISEDRESET

+AUX-

- DC

+

OP

EN

- 24VC

LOS

ED

- 12V

eFlow4NB

L1 min enable2 hr disable GN

- BAT +

1P 1

N

2P 2

N

3P

3N

4P

4N

PO

WE

R D

ISTR

IBU

TIO

NU

NIT

PD4U

L

RS-485 TOFIBER

OPTIC LINK/ REPEATER

ETHERNETTO FIBER

OPTIC MEDIACONVERTER

REMOTEREADER

INTERFACE

12OVACDOUBLE

GANG QUADOUTLET

12 VDC / 7AHBATTERY

12 VDC / 7AHBATTERY

24VDC @ 4AMP

POWERSUPPLY

4 OUTPUTPOWER

DISTRIBUTIONMODULE

RUN CONDUIT FOR VIDEO ANDPOWER CABLES TO SECURITY PANEL

CEILING

100mm x 100mm[4" x 4"] JUNCTION BOX

VIDEO AND POWR CABLESTO SECURITY PANEL

38mm [1.5"] NPT

CAMERA

27mm [1"] NPT

21mm [3/4"] EMT TOFIBER PATCH PANEL

21mm [3/4"] EMT TOSECURITY DEVICES (TYP.)

21mm [3/4"] EMTFOR 120 VAC

DIN RAIL DIN RAIL

DIN RAIL

PROVIDE AND INSTALL 100 x 100 [4" x 4"] JUNCTION BOX AND ROUTE CABLINGFROM BMS TO JUNCTION BOX. WIRE THE 2 BMS IN SERIES.

PROVIDE AND INSTALL SURFACE MOUNT BMS.

PROVIDE AND INSTALL CARD READER. FLUSH MOUNT DUAL GANG BOX ONTHE UNSECURED SIDE TO MOUNT CARD READER AND SURFACE MOUNTDUAL GANG BOX ON SECURED SIDE FOR CONDUIT.

ELECTRIC MORTISE LOCKSET WITH INTEGRAL REQUEST-TO-EXIT SWITCHPROVIDED BY DIVISION 8 CONTRACTOR.

PROVIDE AND INSTALL 405W x 610H x 165D 16"W x 24"H x 6.62"D] NEMA 1 TYPEMETAL ENCLOSURE ON SECURE SIDE.

POWER TRANSFER DEVICE PROVIDED BY DIVISION 8 CONTRACTOR.

PROVIDE AND INSTALL ETHERNET TO FIBER OPTIC MEDIA CONVERTER.

PROVIDE AND INSTALL 25mm [1"] NON-METALLIC WIRE RACEWAY.

PROVIDE AND INSTALL REMOTE READER INTERFACE MODULE.

DOUBLE GANG 120VAC/15 AMP QUAD OUTLET FOR 24VDC POWER SUPPYAND PLUG-IN CAMERA POWER SUPPLY, PROVIDED BY ELECTRICALCONTRACTOR.

PROVIDE AND INSTALL 12VDC, MINIMUM 7AH BATTERIES.

PROVIDE AND INSTALL RS-485 TO FIBER OPTIC CONVERTER WITH ST FIBEROPTIC CABLE CONNECTORS.

PROVIDE AND INSTALL 4-OUPUT POWER DISTRIBUTION MODULE.

PROVIDE AND INSTALL 24VDC @ 4 AMP POWER SUPPLY.

PROVIDE AND INSTALLL A SINGLE GANG BOX JUNCTION BOX TO ROUTECABLING FROM POWER TRANSFER DEVICE.

KEYED NOTES:

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

OFFICE OFRESEARCH FACILITIES

PR

OJE

CT

TITL

E

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEA

LC

ON

TRAC

TOR

SB

UIL

DIN

GP

RO

JEC

TD

RAW

ING

A/E

Nam

e an

d LO

GO

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

11/2

/201

7 1:

52:0

7 PM

L:\D

CS\

Proj

ects

\BD

L\60

5044

85_S

wtc

hgrU

pg\9

00-W

ork\

910-

CAD

\05-

MO

DEL

S\N

IH_S

WG

R-T

ELEC

OM

v20

15.rv

t

T-501

PR

BM

RW

Project Number

TELE

CO

M S

ECU

RIT

Y D

ETAI

LS

46

NOT TO SCALE1 SECURITY DOUBLE DOOR ELEVATION DETAILNOT TO SCALE2 SECURITY DOUBLE DOOR BMS ELEVATION DETAIL

NOT TO SCALE3 SECURITY CAMERA MOUNTING DETAIL NOT TO SCALE4 SECURITY PANEL DETAIL

2

5

1

2

3

4

6

21mm [3/4"] CONDUIT

21mm [3/4"] CONDUITSURFACE MOUNT, TYP.

21mm [3/4"] CONDUITSURFACE MOUNT (TYP.)

FEED CONDUCTORSTHROUGH DOOR

3

2

2

1

27mm [1"] CONDUIT TOFIBER PATCH PANEL

5

21mm [3/4"] CONDUIT TOSECURITY PANEL

7

8

9

10

11

TYP.

12

8

13

8

14

5

15

ACTIVE LEAF FIXED LEAF

JUNCTION BOX

NON-SECUREDSIDE

Page 27: GENERAL NOTES LINE TYPES - cynergyelectric.com · line types a a a a 3 ansi/ieee standard device numbers led, strip light, letter indicates type. lighting fixture, letter indicates

2 STRANDMM FIBER

2 STRANDMM FIBER

2 STRAND FIBER(EXISTING)

18AWG/2C SHIELD

18AWG/2CSHIELD

18AWG/2CSHIELD

18AWG/2C SHIELD

22AWG/2C SHIELD

22AWG/3 PAIROVERALL SHIELD

22AWG/2 PAIROVERALL SHIELD

CAT 6 SHIELDTWISTED PAIR

22AWG/2 TWISTEDPAIR, OVERALL SHIELD

18AWG/2CSHIELDED

EXISTING FIBEROPTIC CABLE FIBER OPTIC

CABLE (GFGI)

INTEGRATEDWITH LOCK

2 STRANDMM FIBER

2 STRAND FIBERCOORDINATE WITH CIT

POWERDISTRIBUTION

MODULE

24VDCPOWER SUPPLY

REMOTEREADER

INTERFACE

RS485 TOFIBERMEDIA

CONVERTER

ETHERNET TOFIBER MEDIACONVERTER

ELECTRICLOCK

REXSWITCH

CARDREADER BMS

BATTERIES

12VDCPOWERSUPPLY

CAMERA

EXISTINGFIBEROPTICPATCHPANEL

120VAC

120VAC

RS485 TO FIBERMEDIA

CONVERTER

ETHERNET TOFIBER MEDIACONVERTER

TO EXISTING VIDEOHEAD END

TO EXISTING ACCESSCONTROL HEAD END

BUILDING 17SECURITY HEAD END LOCATION

BMS

BMS BMS

NEWSUPERVISORY

PANEL

SOUTH DOOR DEVICES NORTH DOOR DEVICES

TO BUILDING 21

EXISTINGSCADA

ENCLOSURE

NEWSCADA

ENCLOSURE

1

4

2

2

3

5

5

3

EXISTING FIBER OPTIC PATCH PANEL CONTAINING 12 STRANDS OFMULTIMODE FIBER OPTIC CABLE AND 12 STRANDS OF SINGLE MODE FIBEROPTIC CABLE. CABLE IS EQUIPPED WITH ST TYPE CONNECTORS.COORDINATE WITH NIH CIT FOR FIBER PATCHING INTO PANEL AND WITHDPSM FOR CONNECTIVITY TO SECURITY HEAD END EQUIPMENT.

PROVIDE FIBER OPTIC CONNECTORS TO INTERFACE TO THE MEDIACONVERTORS AND THE EXISTING FIBER OPTIC PATCH PANEL. COORDINATEWITH NIH CIT.

CONTRACTOR TO VERIFY THAT EXISTING FIBER OPTIC CABLING ISSOURCED FROM THE EXISTING FIBER OPTIC PATCH PANEL. COORDINATEWITH ELECTRICAL CONTRACTOR FOR FIBER OPTIC CABLING ANDCONNECTOR TYPE.

12VDC POWER SUPPLY AS SPECIFIED BY CAMERA BY MANUFACTURER.

PROVIDE AND INSTALL MEDIA CONVERTERS AND CABLING TO EXISTINGHEAD END EQUIPMENT. COORDINATE LOCATION AND CONNECTION TOHEAD END EQUIPMENT WITH DPSM.

KEYED NOTES:1

2

3

4

5

Last

Plo

tted:

File

nam

e:

12345

A

B

C

D

5 4 3 2 1

OFFICE OFRESEARCH FACILITIES

PR

OJE

CT

TITL

E

DR

AWIN

GTI

TLE

MARK DATE DESCRIPTION

REV

ISIO

NS

SEA

LC

ON

TRAC

TOR

SB

UIL

DIN

GP

RO

JEC

TD

RAW

ING

A/E

Nam

e an

d LO

GO

A/E CON. NO.

A/E TASK NO.

CONS. CONTR.

CONS. WORK

PRIME A/E

SUB A/E

CONSTR. CON.

FACILITY CODE

BUILDING NO.

NAME

STREET

CITY

STATE/ZIP

OTHER

BUILDING NO.

PROJ. NO.

PROJ. OFFICER

PROJ. MGR.

SUBMISSION

SUB. DATE

WRK REQ. NO.

Bethesda NIH Campus

9000 Rockville Pike

Bethesda

MD, 20892

ISSUE FOR CONSTRUCTION

11/03/2017

DESIGNED BY

DRAWN BY

CHECKED BY

FILE NAME

DRAWING NO.

SHEET OF 47

AECOM

UPG

RAD

E EL

E CTR

ICAL

SU

BSTA

TIO

N

HHSN292201400001I

HHSN29200011

EDG-2

17

17

DT

JL

C102846

11/2

/201

7 1:

52:0

9 PM

L:\D

CS\

Proj

ects

\BD

L\60

5044

85_S

wtc

hgrU

pg\9

00-W

ork\

910-

CAD

\05-

MO

DEL

S\N

IH_S

WG

R-T

ELEC

OM

v20

15.rv

t

T-601

PR

BM

RW

Project Number

SEC

UIR

TY R

ISER

DIA

GR

AM

47