general mulling information
TRANSCRIPT
![Page 1: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/1.jpg)
1 19972255Marvin Signature CollectionArchitectural Detail Manual
General Mulling InformationGeneral Mull Information - Mull Types ................................................................................................................... 3Ultimate Casement Mull Types .............................................................................................................................. 9Ultimate Casement Narrow Frame Mull Types ...................................................................................................... 23Ultimate Direct Glaze Mull Types........................................................................................................................... 37Ultimate Direct Glaze Round Top Mull Types ........................................................................................................ 49Ultimate Direct Glaze Narrow Frame Mull Types ................................................................................................... 61Ultimate Double Hung G2 Mull Types.................................................................................................................... 75Ultimate Glider Mull Types ..................................................................................................................................... 91Multi-High, Multi-Wide Mulling................................................................................................................................ 101Ultimate Inswing French Door Mull Types.............................................................................................................. 107Ultimate Outswing French Door Mull Types........................................................................................................... 111Ultimate Sliding French Door Mull Types............................................................................................................... 115Ultimate Sliding Patio Door Mull Types.................................................................................................................. 119Modern Casement Mull Types ............................................................................................................................... 123Modern Direct Glaze Mull Types............................................................................................................................ 127Modern Swinging Doors Mull Types....................................................................................................................... 131Modern Additional Steel Mull Types....................................................................................................................... 135
![Page 2: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/2.jpg)
219972255
Marvin Signature Collection Architectural Detail Manual
![Page 3: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/3.jpg)
Mull-3 19972255Marvin Signature Collection Architectural Detail Manual
General Mulling Information
Ver 2019.3 2019-07-29
General Mull Information - Mull TypesMarvin offers a variety of mull options for many of the Marvin window and door projects. Some mulls can be done in the factory.Others would need to be done in the field. Some mulls create a certified assembly according to third-party testing.
Marvin Mull Options:Marvin-SuppliedStandard Mull (Ultimate): Two units mulled directly together without any reinforcement or space mulls between the frames. Standard Mull (Modern): 2 or more units mulled directly together with the standard 1/2" x 2 1/4" Aluminum; requires standard
interior and exterior mull covers. 3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or field
assembly of the mullion.Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.
◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull Reinforcement: Laminated Veneered Lumber is used as a solid space mull.
◦ LVL is 1.7 to 1.9 times stronger than regular wood. ◦ 1" and 2" widths are available from Marvin.
Space Mull: Non-continuous blocks of wood are used to space units apart. ◦ 3/8", 1", 2", 3", 4" and 6" widths are available.
Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation of an existingstructure in the opening. Units are shipped with temporary blocking. Remove before installation.
Field Supplied and Applied (these are other available mulling options, not provided by Marvin) Tube Mull: Tube aluminum or steel used to reinforce mulled assemblies. Flat Mull: Flat Steel or Aluminum used to reinforce mulled assemblies. These reinforcement types must be primed to prevent corrosion.
AnchoringSpecial considerations need to be made when installing mulled assemblies. Mullions create point loads that need to be
transferred to the rough opening. For Marvin standard, MRF, LVL, and space mulls, the ends of the mull need to be fastened oneach side of the splice with either jamb screws or brackets. Aluminum, steel and other structural mulls need to be anchoreddirectly to the rough opening or building structure.
Section Details:Cross sections will illustrate the mulling of two units.Tributary and Span:Tributary Width - The area supported by the mullion. In the case of a vertical mull, this is equal to the sum of half of the width of eachunit on each side of the mull.Span - The length of the mullion
TributaryWidth
Span
TributaryWidth
TributaryWidth
TributaryWidth
Span
Ribbon Mull Stacked Mull
![Page 4: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/4.jpg)
General Mulling Information
Mull-4 19972255Marvin Signature CollectionArchitectural Detail Manual
Ver 2020.1 2020-01-13
General Mull Information - Mull TypesCharts:
Mullion Performance ChartsIn accordance with the International Building Code, mullion performance is determined through either physical testing or calculations. A combination of both methods has been used to develop the performance charts. Calculated mulls limit deflection to L/175 (L=length of mullion) and limit allowable stress to 2/3 of the mull material’s allowable stress. Physically tested mulls often outperform calculations and this will show up on the charts as jumps in performances.
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58
59606162 PG 65 DP 50 636465666768 DP 40 697071727374 PG50 DP 30 75767778798081828384 DP 20 85 DP 50 86878889909192939495969798 PG4099
100101102103104105106107108109110 DP30111 DP20112113114115116117118119120
Span
Tributary Width
Tested Sizes
Tested Size
Calculated Range
All sizes shown are in accordance with AAMA-450 and Building Codes.
PG – Performance Grade – These sizes have been physically tested for Air/Water and Structural Performance and are certified by WDMA.
DP – Design Pressure – These sizes have not been physically tested. The calculated range demonstrates the maximum range allowed for Structural Performance values.
![Page 5: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/5.jpg)
Mull-5 19972255Marvin Signature Collection Architectural Detail Manual
General Mulling Information
Ver 2019.3 2019-07-29
Field-Supplied and Applied Mull Types
![Page 6: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/6.jpg)
General Mulling Information
Mull-6 19972255Marvin Signature CollectionArchitectural Detail Manual
Ver 2019.3 2019-07-29
Marvin Mull TypesNOTE: Mulls displayed with Ultimate Casement frames, but other products can also be used.
![Page 7: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/7.jpg)
Mull-7 19972255Marvin Signature Collection Architectural Detail Manual
General Mulling Information
Ver 2019.3 2019-07-29
Marvin Mull TypesNOTE: Mulls displayed with Ultimate Casement frames, but other products can also be used.
![Page 8: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/8.jpg)
General Mulling Information
Mull-8 19972255Marvin Signature CollectionArchitectural Detail Manual
Ver 2019.3 2019-07-29
![Page 9: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/9.jpg)
Mull-9 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Casement Mull TypesMarvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Ultimate Casement product.
Mull Types:Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames. 3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or field
assembly of the mullion.Space Mull: Non-continuous blocks of wood are used to space units apart.
◦ 3/8", 1", 2", 3", 4" and 6" widths are available.Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.
◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull: Laminated Veneered Lumber is used as a solid space mull.
◦ LVL is 1.7 to 1.9 times stronger than regular wood. ◦ 1" and 2" widths are available.
Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation around anexisting structure in the opening.
Products IncludedUltimate Casement and AwningUltimate Casement PictureUltimate Venting PictureUltimate Pushout Casement and Awning Ultimate Casement French and Ultimate Casement Push Out French IZ3
Certified Mull Installation Methods:Masonry Clips Jamb ScrewsStructural Brackets
Tributary and Span:Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.
TributaryWidth
Span
TributaryWidth
TributaryWidth
TributaryWidth
Span
Ribbon Mull Stacked Mull
![Page 10: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/10.jpg)
Clad Mulling
Mull-10 19972255Marvin Signature CollectionArchitectural Detail Manual
Ver 2019.3 2019-07-29
Section Details: Ultimate Casement Mulling Types
![Page 11: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/11.jpg)
Mull-11 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Section Details: Ultimate Casement Mulling Types (Continued)
Space Mulls and Solid Space Mulls are available in3/8", 1", 2", 3", 4" and 6" widths.
Marvin provides interior mull trim for mulls up to 2".
![Page 12: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/12.jpg)
Clad Mulling
Mull-12 19972255Marvin Signature CollectionArchitectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Casement Mulling - Standard Frame (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58 DP 65
59606162 PG 65 DP 50 636465666768 DP 40 697071727374 PG50 DP 30 75767778798081828384 DP 20 85 DP 50 86878889909192939495969798 PG4099
100101102103104105106107108109110 DP30111 DP20112113114115116117118119120
Span
Tributary Width
![Page 13: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/13.jpg)
Mull-13 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Casement Mulling - 3/8" Mull Reinforcement (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58
596061 DP5626364656667686970717273 DP50747576777879808182 DP408384858687888990919293949596979899
100 DP40101102103104 DP30105106107 DP20108109110111112113 DP25114115116117118119120
Span
Tributary Width
![Page 14: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/14.jpg)
Clad Mulling
Mull-14 19972255Marvin Signature CollectionArchitectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Casement Mulling - 1" LVL (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58
596061 DP65626364656667686970717273747576 DP5077787980818283848586878889909192 DP4093949596979899
100 DP30101102103104105106107108109110 DP20111112113114115116117118119120
Tributary Width
Span
![Page 15: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/15.jpg)
Mull-15 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Casement Mulling - 2" LVL (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58
596061 DP65626364656667686970717273747576 DP5077787980818283848586878889909192 DP4093949596979899
100 DP30101102103104105106107108109110111112113114115 DP20116117118119120
Span
Tributary Width
![Page 16: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/16.jpg)
Clad Mulling
Mull-16 19972255Marvin Signature CollectionArchitectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Casement Mulling - 3/8" Solid Space Mull (Ribbon or Stacked Assembly)
![Page 17: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/17.jpg)
Mull-17 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Casement Mulling - 1" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58
5960 DP6561626364656667 DP5068697071727374 DP407576777879808182 DP3083848586878889909192 DP2093949596979899
100101102103104105106107108109110111112113114115116117118119120
Tributary Width
Span
![Page 18: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/18.jpg)
Clad Mulling
Mull-18 19972255Marvin Signature CollectionArchitectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Casement Mulling - 2" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58
596061 DP6562636465666768697071 DP5072737475767778798081 DP408283848586878889909192939495 DP3096979899
100101102103104105106107108 DP20109110111112113114115116117118119120
Tributary Width
Span
![Page 19: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/19.jpg)
Mull-19 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Casement Mulling - 3" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58
596061 DP6562636465666768697071 DP507273747576777879808182 DP408384858687888990919293949596 DP30979899
100101102103104105106107108109110111112113114115 DP20 116117118119120
Span
Tributary Width
![Page 20: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/20.jpg)
Clad Mulling
Mull-20 19972255Marvin Signature CollectionArchitectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Casement Mulling - 4" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88
24-58
59
60
61
62 DP65
63
64
65
66
67
68
69
70
71 DP50
72
73
74
75
76
77
78
79
80
81 DP40
82
83
84
85
86
87
88
89
90
91
92
93
94 DP30
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109 DP20
110
111
112
113
114
115
116
117
118
119
120
Span
Tributary Width
![Page 21: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/21.jpg)
Mull-21 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Casement Mulling - 6" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58
596061 DP6562636465666768697071 DP5072737475767778798081 DP4082838485868788899091929394 DP309596979899
100101102103104105106107108109110111 DP20112113114115116117118119120
Span
Tributary Width
![Page 22: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/22.jpg)
Clad Mulling
Mull-22 19972255Marvin Signature CollectionArchitectural Detail Manual
Ver 2019.3 2019-07-29
![Page 23: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/23.jpg)
Mull-23 19972255Marvin Signature Collection Architectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Casement Narrow Frame Mull TypesMarvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Ultimate Casement Narrow Frame product.
Mull Types:Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames. 3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or field
assembly of the mullion.Space Mull: Non-continuous blocks of wood are used to space units apart.
◦ 3/8", 1", 2", 3", 4" and 6" widths are available.Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.
◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull: Laminated Veneered Lumber is used as a solid space mull.
◦ LVL is 1.7 to 1.9 times stronger than regular wood. ◦ 1" and 2" widths are available.
Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation around anexisting structure in the opening.
Products IncludedUltimate Casement Narrow FrameUltimate Awning Narrow FrameUltimate Casement Push Out Narrow Frame Ultimate Awning Push Out Narrow FrameUltimate Casement/Awning Narrow Frame Picture
NOTE: Multi-High Multi-Wide Assemblies with any side that exceed 72” in either direction will be shipped with a temporary blockingaround the entire perimeter of the assembly to provide support during shipping and handling.
Certified Mull Installation Methods: Jamb Screws
Tributary and Span:Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.
TributaryWidth
Span
TributaryWidth
TributaryWidth
TributaryWidth
Span
Ribbon Mull Stacked Mull
![Page 24: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/24.jpg)
Clad Mulling
Mull-24 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Section Details: Ultimate Casement Narrow Frame Mulling Types
![Page 25: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/25.jpg)
Mull-25 19972255Marvin Signature Collection Architectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Section Details: Ultimate Casement Narrow Frame Mulling Types (Continued)
Space Mulls and Solid Space Mulls areavailable in 3/8", 1", 2", 3", 4" and 6" widths.
Marvin provides interior mull trim for mullsup to 2".
![Page 26: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/26.jpg)
Clad Mulling
Mull-26 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Casement Narrow Frame Mulling-Standard Frame (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 722425262728293031 PG50 DP5032333435363738394041 DP 40 424344 DP3045464748495051 DP205253545556575859606162636465666768 PG406970717273747576777879 PG308081828384
Span
Tributary Width
![Page 27: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/27.jpg)
Mull-27 19972255Marvin Signature Collection Architectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Casement Narrow Frame Mulling - 3/8" Mull Reinforcement (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224252627282930313233343536373839404142 DP50434445464748495051525354555657585960616263646566 DP4067686970717273747576 DP407778 DP 307980818283848586878889 DP 209091929394959697
Tributary Width
Span
![Page 28: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/28.jpg)
Clad Mulling
Mull-28 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Casement Narrow Frame Mulling - 1" LVL (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224-31
323334353637383940 PG50 DP5041424344454647484950 DP4051525354 DP3055565758596061 DP2062636465666768697071727374 DP207576777879808182
Span
Tributary Width
![Page 29: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/29.jpg)
Mull-29 19972255Marvin Signature Collection Architectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Casement Narrow Frame Mulling - 2" LVL (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224-31
323334353637383940414243444546 PG50 DP50474849505152535455565758 DP4059606162 DP30636465666768 DP20697071727374 DP3075767778798081828384 DP20858687888990919293
Tributary Width
Span
![Page 30: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/30.jpg)
Clad Mulling
Mull-30 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Casement Narrow Frame Mulling - 3/8" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224252627282930313233 DP5034353637383940414243 DP4044454647 DP3048495051525354 DP205556575859606162636465666768697071
Tributary Width
Span
![Page 31: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/31.jpg)
Mull-31 19972255Marvin Signature Collection Architectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Casement Narrow Frame Mulling - 1" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224252627282930313233343536373839 DP5040414243444546 DP4047484950 DP30515253545556 DP205758596061626364656667686970717273747576
Span
Tributary Width
![Page 32: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/32.jpg)
Clad Mulling
Mull-32 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Casement Narrow Frame Mulling - 2" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224-31
32333435 DP50363738394041424344454647484950 DP405152535455 DP3056575859606162 DP206364656667686970717273747576777879808182
Tributary Width
Span
![Page 33: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/33.jpg)
Mull-33 19972255Marvin Signature Collection Architectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Casement Narrow Frame Mulling - 3" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224-31
3233343536 DP50373839404142434445464748495051525354 DP405556575859 DP3060616263646566 DP206768697071727374757677787980818283848586878889
Tributary Width
Span
![Page 34: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/34.jpg)
Clad Mulling
Mull-34 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Casement Narrow Frame Mulling - 4" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224-41
424344454647 DP504849505152535455565758 DP405960616263 DP30646566676869 DP207071727374757677787980818283848586878889909192939495
Tributary Width
Span
![Page 35: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/35.jpg)
Mull-35 19972255Marvin Signature Collection Architectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Casement Narrow Frame Mulling - 6" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224-41
42434445464748495051 DP5052535455565758596061626364 DP4065666768 DP3069707172737475 DP2076777879808182838485868788899091929394959697
Tributary Width
Span
![Page 36: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/36.jpg)
Clad Mulling
Mull-36 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
![Page 37: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/37.jpg)
Mull-37 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Mull TypesMarvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Ultimate Direct Glaze product.
Mull Types:Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames. 3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or field
assembly of the mullion.Space Mull: Non-continuous blocks of wood are used to space units apart.
◦ 3/8", 1", 2", 3", 4" and 6" widths are available.Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.
◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull: Laminated Veneered Lumber is used as a solid space mull.
◦ LVL is 1.7 to 1.9 times stronger than regular wood. ◦ 1" and 2" widths are available.
Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation around anexisting structure in the opening.
Products IncludedUltimate Direct GlazeUltimate Direct Glaze IZ3
Certified Mull Installation MethodsMasonry Clips Jamb ScrewsStructural Brackets
Tributary and Span:Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.
TributaryWidth
Span
TributaryWidth
TributaryWidth
TributaryWidth
Span
Ribbon Mull Stacked Mull
![Page 38: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/38.jpg)
Clad Mulling
Mull-38 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Section Details: Ultimate Direct Glaze Mulling Types
![Page 39: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/39.jpg)
Mull-39 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Section Details: Ultimate Direct Glaze Mulling Types (Continued)
Space Mulls and Solid Space Mulls are avail-able in 3/8", 1", 2", 3", 4" and 6" widths.
Marvin provides interior mull trim for mulls upto 2".
![Page 40: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/40.jpg)
Clad Mulling
Mull-40 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Mulling - Standard Frame (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88363840424446 DP6548505254565860626466 DP50687072 DP40747678 DP308082848688 DP 209092 PG50949698
100102 PG40104106108110 DP30112114 DP20116118120
Tributary Width
Span
![Page 41: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/41.jpg)
Mull-41 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Mulling - 3/8" Mull Reinforcement (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 883638404244464850 DP655254565860626466687072 DP507476788082 DP408486889092 DP30949698
100102104106 DP20108110112114116118120
Span
Tributary Width
![Page 42: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/42.jpg)
Clad Mulling
Mull-42 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Mulling - 1" LVL (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8836384042444648505254 DP65565860626466687072 DP507476788082 DP408486889092 DP30949698
100102104106 DP20108110112114116118120
Span
Tributary Width
![Page 43: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/43.jpg)
Mull-43 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Mulling - 2" LVL (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88363840424446 DP6548505254565860626466687072 DP507476788082 DP40848688909294 DP309698
100102104106108110 DP20112114116118120
Span
Tributary Width
![Page 44: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/44.jpg)
Clad Mulling
Mull-44 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Mulling - 3/8" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88363840424446485052 DP65545658606264666870 DP50727476 DP4078808284 DP308688909294 DP209698
100102104106108110112114116118120
Tributary Width
Span
![Page 45: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/45.jpg)
Mull-45 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Mulling - 1" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88363840424446485052 DP6554565860626466687072 DP507476788082 DP4084868890 DP3092949698
100 DP20102104106108110112114116118120
Span
Tributary Width
![Page 46: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/46.jpg)
Clad Mulling
Mull-46 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Mulling - 2" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88363840424446485052 DP6554565860626466687072 DP507476788082 DP40848688909294 DP309698
100102104106108 DP20110112114116118120
Span
Tributary Width
![Page 47: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/47.jpg)
Mull-47 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Mulling - 3" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8836384042444648 DP65505254565860626466687072 DP507476788082 DP40848688909294 DP309698
100102104106108110 DP20112114116118120
Span
Tributary Width
![Page 48: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/48.jpg)
Clad Mulling
Mull-48 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Mulling - 4" and 6" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 883638404244464850 DP655254565860626466687072 DP507476788082 DP40848688909294 DP309698
100102104106108110112 DP20114116118120
Span
Tributary Width
![Page 49: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/49.jpg)
Mull-49 19972255Marvin Signature Collection Architectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Round Top Mull TypesMarvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Ultimate Direct Glaze Round Top product.
Mull Types:Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames. 3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or field
assembly of the mullion.Space Mull: Non-continuous blocks of wood are used to space units apart.
◦ 3/8", 1", 2", 3", 4" and 6" widths are available.Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.
◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull: Laminated Veneered Lumber is used as a solid space mull.
◦ LVL is 1.7 to 1.9 times stronger than regular wood. ◦ 1" and 2" widths are available.
Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation around anexisting structure in the opening.
Products IncludedUltimate Direct Glaze Round TopUltimate Direct Glaze Polygon 4/4Ultimate Direct Glaze Round Top IZ3
Certified Mull Installation MethodsMasonry Clips Jamb ScrewsStructural Brackets
Tributary and SpanTributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.
TributaryWidth
Span
TributaryWidth
TributaryWidth
TributaryWidth
Span
Ribbon Mull Stacked Mull
![Page 50: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/50.jpg)
Clad Mulling
Mull-50 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Section Details: Ultimate Direct Glaze Round Top Mulling Types
![Page 51: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/51.jpg)
Mull-51 19972255Marvin Signature Collection Architectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Section Details: Ultimate Direct Glaze Round Top Mulling Types (Continued)
Space Mulls and Solid Space Mulls are avail-able in 3/8", 1", 2", 3", 4" and 6" widths.
Marvin provides interior mull trim for mulls up to2".
![Page 52: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/52.jpg)
Clad Mulling
Mull-52 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Round Top Mulling - Standard Frame (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 883638404244 DP6546485052545658 DP50606264 DP4066687072 DP307476788082 DP208486889092949698
100102104106108110112114116118120
Tributary Width
Span
![Page 53: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/53.jpg)
Mull-53 19972255Marvin Signature Collection Architectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Round Top Mulling - 3/8" Mull Reinforcement (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8836384042444648 DP505254565860626466687072 DP50747678808284 DP408688909294 DP309698100102104 DP20106108110112114116118120
Tributary Width
Span
![Page 54: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/54.jpg)
Clad Mulling
Mull-54 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Round Top Mulling - 1" LVL (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8836384042444648 DP6550525456586062646668707274 DP50767880828486 DP408890929496 DP3098
100102104106 DP20108110112114116118120
Tributary Width
![Page 55: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/55.jpg)
Mull-55 19972255Marvin Signature Collection Architectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Round Top Mulling - 2" LVL (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 883638404244464850 DP655254565860626466687072 DP507476788082 DP4084868890929496 DP3098
100102104106108110112114 DP20116118120
Span
Tributary Width
![Page 56: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/56.jpg)
Clad Mulling
Mull-56 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Round Top Mulling - 3/8" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 883638404244464850 DP655254565860626466687072 DP507476788082 DP4084868890929496 DP3098
100102104106108110112114 DP20116118120
Span
Tributary Width
![Page 57: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/57.jpg)
Mull-57 19972255Marvin Signature Collection Architectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Round Top Mulling - 1" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8836384042444648 DP655052545658606264666870 DP5072747678 DP4080828486 DP308890929496 DP2098
100102104106108110112114116118120
Span
Tributary Width
![Page 58: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/58.jpg)
Clad Mulling
Mull-58 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Round Top Mulling - 2" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8836384042444648 DP6550525456586062646668707274 DP50767880828486 DP408890929496 DP3098
100102104106108 DP20110112114116118120
Tributary Width
Span
![Page 59: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/59.jpg)
Mull-59 19972255Marvin Signature Collection Architectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Round Top Mulling - 3" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8836384042444648 DP65505254565860626466687072 DP 50747678808284 DP4086889092949698 DP30
100102104106108110112 DP20114116118120
Span
Tributary Width
![Page 60: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/60.jpg)
Clad Mulling
Mull-60 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Round Top Mulling - 4" and 6" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8836384042444648 DP65505254565860626466687072 DP50747678808284 DP4086889092949698 DP30
100102104106108110 DP20112114116118120
Tributary Width
Span
![Page 61: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/61.jpg)
Mull-61 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Narrow Frame Mull TypesMarvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Ultimate Direct Glaze Narrow Frame product.
Mull Types:Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames. 3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or field
assembly of the mullion.Space Mull: Non-continuous blocks of wood are used to space units apart.
◦ 3/8", 1", 2", 3", 4" and 6" widths are available.Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.
◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull: Laminated Veneered Lumber is used as a solid space mull.
◦ LVL is 1.7 to 1.9 times stronger than regular wood. ◦ 1" and 2" widths are available.
Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation around anexisting structure in the opening.
Products Included Narrow Frame (Contemporary) Direct Glaze
NOTE: Multi-High Multi-Wide Assemblies with any side that exceed 72” in either direction will be shipped with a temporary blockingaround the entire perimeter of the assembly to provide support during shipping and handling.
Certified Mull Installation Methods Jamb Screws
Tributary and Span:Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.
TributaryWidth
Span
TributaryWidth
TributaryWidth
TributaryWidth
Span
Ribbon Mull Stacked Mull
![Page 62: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/62.jpg)
Clad Mulling
Mull-62 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Section Details: Ultimate Direct Glaze Narrow Frame Mulling Types
![Page 63: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/63.jpg)
Mull-63 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Section Details: Ultimate Direct Glaze Narrow Frame Mulling Types (Continued)
Space Mulls and Solid Space Mulls are avail-able in 3/8", 1", 2", 3", 4" and 6" widths.
Marvin provides interior mull trim for mulls upto 2".
![Page 64: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/64.jpg)
Clad Mulling
Mull-64 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Narrow Frame Mulling - Standard Frame (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-1203638404244 PG50 DP504648505254 DP40565860 DP30626466 DP20687072747678808284 PG25868890929496
Span
Tributary Width
![Page 65: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/65.jpg)
Mull-65 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Narrow Frame Mulling - 3/8" Mull Reinforcement(Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-1203638404244 DP5046485052545658606264666870 DP40727476 DP 30788082 DP 208486889092949698100102104106108110112114116118120
Tributary Width
Span
![Page 66: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/66.jpg)
Clad Mulling
Mull-66 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Narrow Frame Mulling - 1" LVL (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-1203638404244 DP504648505254565860 DP40626466 DP30687072 DP2074767880828486889092949698
Span
Tributary Width
![Page 67: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/67.jpg)
Mull-67 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Narrow Frame Mulling - 2" LVL (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-1203638404244 DP504648505254565860 DP40626466 DP30687072 DP2074767880828486889092949698
Span
Tributary Width
![Page 68: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/68.jpg)
Clad Mulling
Mull-68 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Narrow Frame Mulling - 3/8" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-1203638404244 DP50464850525456 DP40586062 DP30646668 DP20707274767880828486889092
Span
Tributary Width
![Page 69: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/69.jpg)
Mull-69 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Narrow Frame Mulling - 1" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 '88-1203638404244 DP5046485052545658 DP40606264 DP30666870 DP2072747678808284868890929496
Span
Tributary Width
![Page 70: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/70.jpg)
Clad Mulling
Mull-70 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Narrow Frame Mulling - 2" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-120363840424446 DP50485052545658 DP40606264 DP3066687072 DP2074767880828486889092949698
100
Span
Tributary Width
![Page 71: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/71.jpg)
Mull-71 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Narrow Frame Mulling - 3" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-12036384042444648 DP5050525456586062 DP40646668 DP30707274 DP20767880828486889092949698
100102104
Span
Tributary Width
![Page 72: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/72.jpg)
Clad Mulling
Mull-72 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Narrow Frame Mulling - 4" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-12036384042444648 DP505052545658606264 DP40666870 DP30727476 DP207880828486889092949698
100102104106108
Span
Tributary Width
![Page 73: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/73.jpg)
Mull-73 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Direct Glaze Narrow Frame Mulling - 6" Solid Space Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-120363840424446485052 DP505456586062646668 DP407072 DP3074767880 DP20828486889092949698
100102104106108110112114
Span
Tributary Width
![Page 74: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/74.jpg)
Clad Mulling
Mull-74 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
![Page 75: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/75.jpg)
Mull-75 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Double Hung G2 Mull TypesMarvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Ultimate Double Hung G2 product.
Mull Types:Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames. 3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or field
assembly of the mullion.Space Mull: Non-continuous blocks of wood are used to space units apart.
◦ 3/8", 1", 2", 3", 4" and 6" widths are available.Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.
◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull: Laminated Veneered Lumber is used as a solid space mull.
◦ LVL is 1.7 to 1.9 times stronger than regular wood. ◦ 1" and 2" widths are available.
Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation around anexisting structure in the opening.
Products IncludedUltimate Double Hung G2Ultimate Double Hung G2 IZ3
Certified Mull Installation MethodsMasonry Clips
Tributary and Span:Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.
TributaryWidth
Span
TributaryWidth
TributaryWidth
TributaryWidth
Span
Ribbon Mull Stacked Mull
![Page 76: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/76.jpg)
Clad Mulling
Mull-76 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Section Details: Ultimate Double Hung G2 Mulling Types
![Page 77: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/77.jpg)
Mull-77 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Section Details: Ultimate Double Hung G2 Mulling Types (Continued)
![Page 78: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/78.jpg)
Clad Mulling
Mull-78 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Section Details: Ultimate Double Hung G2 Mulling Types (Continued)
Space Mulls and Solid Space Mulls areavailable in 3/8", 1", 2", 3", 4" and 6" widths.
Marvin provides interior mull trim for mulls upto 2".
![Page 79: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/79.jpg)
Mull-79 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Section Details: Ultimate Double Hung G2 Mulling Types (Continued)
Space Mulls and Solid Space Mulls are also available in 1", 2", 3" and 4" widths.
Marvin provides interior mull trim for mulls up to 2".
![Page 80: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/80.jpg)
Clad Mulling
Mull-80 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Double Hung G2 Mulling - Standard Frame (Vertical) (Ribbon or Stacked Assembly)
CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25
12 31.5
14 35.5
16 39.5 DP65
18 43.5
20 47.5 PG65
22 51.5 DP 50
24 55.5 DP40
26 59.5 DP30
28 63.5 DP20
30 67.5 PG50
32 71.5
34 75.5
36 79.5
38 83.5 PG 25
40 87.5
42 91.5
44 95.5
Tributary Width
Span
![Page 81: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/81.jpg)
Mull-81 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Double Hung G2 Mulling - Standard Frame (Horizontal) (Ribbon or Stacked Assembly)
Frame OM 21.25 25.25 29.25 33.25 37.25 41.25 45.25 49.25 53.25 57.25 61.25 65.25 69.25 73.25
51.188
53.188
55.188
57.188
59.188
61.188
63.188
65.188
67.188 DP65
69.188
71.188
73.188
75.188
77.188
79.188
81.188
83.188
85.188
87.188
89.188
91.188
93.188 DP50
95.188
97.188
99.188
101.188
103.188
105.188
107.188
109.188
111.188
113.188
115.188
117.188
119.188
121.188
123.188
125.188
127.188 DP50 DP45
129.188
131.188
133.188
135.188
137.188
139.188
141.188
143.188
145.188
147.188
149.188
151.188
153.188
Span
Tributary Width (combined unit heights/2)
![Page 82: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/82.jpg)
Clad Mulling
Mull-82 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Double Hung G2 Mulling - 1" LVL (Vertical) (Ribbon or Stacked Assembly)
CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25
12 31.5
14 35.5
16 39.5
18 43.5
20 47.5 DP65
22 51.5
24 55.5
26 59.5
28 63.5
30 67.5
32 71.5
34 75.5 DP50
36 79.5
38 83.5 DP40
40 87.5 DP 30
42 91.5
44 95.5
46 99.5 DP 20
48 103.5
50 107.5
52 111.5
54 115.5
56 119.5
58 123.5
60 127.5
Span
Tributary Width
![Page 83: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/83.jpg)
Mull-83 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Double Hung G2 Mulling - 2" LVL (Vertical) (Ribbon or Stacked Assembly)
CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25
12 31.5
14 35.5
16 39.5
18 43.5
20 47.5 DP65
22 51.5
24 55.5
26 59.5
28 63.5
30 67.5
32 71.5
34 75.5
36 79.5 DP50
38 83.5
40 87.5
42 91.5 DP40
44 95.5
46 99.5
48 103.5
50 107.5 DP30
52 111.5
54 115.5
56 119.5 DP20
58 123.5
60 127.5
Tributary Width
Span
![Page 84: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/84.jpg)
Clad Mulling
Mull-84 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Double Hung G2 Mulling - 3/8" Mull Reinforcement (Ribbon or Stacked Assembly)
CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25
12 31.5
14 35.5
16 39.5
18 43.5
20 47.5
22 51.5 DP DP65
24 55.5
26 59.5
28 63.5
30 67.5
32 71.5 DP50
34 75.5
36 79.5
38 83.5 DP40
40 87.5
42 91.5
44 95.5 DP30
46 99.5 DP20
48 103.5
50 107.5
52 111.5
54 115.5
56 119.5
58 123.5
60 127.5
Tributary Width
Span
![Page 85: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/85.jpg)
Mull-85 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Double Hung G2 Mulling - 3/8" Solid Space Mull (Ribbon or Stacked Assembly)
CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25
12 31.5
14 35.5
16 39.5 DP65
18 43.5
20 47.5
22 51.5 DP50
24 55.5
26 59.5 DP40
28 63.5 DP30
30 67.5
32 71.5
34 75.5 DP20
36 79.5
38 83.5
40 87.5
42 91.5
44 95.5
46 99.5
48 103.5
Tributary Width
Span
![Page 86: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/86.jpg)
Clad Mulling
Mull-86 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Double Hung G2 Mulling - 1" Solid Space Mull (Ribbon or Stacked Assembly)
CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25
12 31.5
14 35.5
16 39.5
18 43.5 DP65
20 47.5
22 51.5
24 55.5
26 59.5
28 63.5 DP50
30 67.5
32 71.5 DP40
34 75.5
36 79.5
38 83.5 DP30
40 87.5
42 91.5 DP20
44 95.5
46 99.5
48 103.5
50 107.5
52 111.5
54 115.5
56 119.5
58 123.5
60 127.5
Span
Tributary Width
![Page 87: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/87.jpg)
Mull-87 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Double Hung G2 Mulling - 2" Solid Space Mull (Ribbon or Stacked Assembly)
CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60
CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25
12 31.5
14 35.5
16 39.5
18 43.5
20 47.5
22 51.5 DP65
24 55.5
26 59.5
28 63.5
30 67.5
32 71.5
34 75.5 DP50
36 79.5
38 83.5 DP40
40 87.5
42 91.5 DP30
44 95.5
46 99.5
48 103.5
50 107.5 DP20
52 111.5
54 115.5
56 119.5
58 123.5
60 127.5
Span
Tributary Width
![Page 88: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/88.jpg)
Clad Mulling
Mull-88 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Double Hung G2 Mulling - 3" Solid Space Mull (Ribbon or Stacked Assembly)
CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25
12 31.5
14 35.5
16 39.5
18 43.5
20 47.5 DP65
22 51.5
24 55.5
26 59.5
28 63.5
30 67.5
32 71.5
34 75.5 DP50
36 79.5
38 83.5
40 87.5 DP40
42 91.5
44 95.5
46 99.5 DP30
48 103.5
50 107.5
52 111.5 DP20
54 115.5
56 119.5
58 123.5
60 127.5Span
Tributary Width
![Page 89: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/89.jpg)
Mull-89 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Double Hung G2 Mulling - 4" Solid Space Mull (Ribbon or Stacked Assembly)
CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25
12 31.5
14 35.5
16 39.5
18 43.5
20 47.5 DP65
22 51.5
24 55.5
26 59.5
28 63.5
30 67.5
32 71.5
34 75.5 DP50
36 79.5
38 83.5
40 87.5 DP40
42 91.5
44 95.5
46 99.5 DP30
48 103.5
50 107.5
52 111.5 DP20
54 115.5
56 119.5
58 123.5
60 127.5Span
Tributary Width
![Page 90: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/90.jpg)
Clad Mulling
Mull-90 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Double Hung G2 Mulling - 6" Solid Space Mull (Ribbon or Stacked Assembly)
CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25
12 31.5
14 35.5
16 39.5
18 43.5
20 47.5 DP65
22 51.5
24 55.5
26 59.5
28 63.5
30 67.5
32 71.5
34 75.5
36 79.5 DP50
38 83.5
40 87.5
42 91.5
44 95.5 DP40
46 99.5
48 103.5
50 107.5
52 111.5 DP30
54 115.5
56 119.5 DP20
58 123.5
60 127.5
Span
Tributary Width
![Page 91: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/91.jpg)
Mull-91 19972255Marvin Signature Collection Architectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Glider Mull TypesMarvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Ultimate Glider product.
Mull Types:Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames. 3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or field
assembly of the mullion.Space Mull: Non-continuous blocks of wood are used to space units apart.
◦ 3/8", 1", 2", 3", 4" and 6" widths are available.Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.
◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull: Laminated Veneered Lumber is used as a solid space mull.
◦ LVL is 1.7 to 1.9 times stronger than regular wood. ◦ 1" and 2" widths are available.
Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation of an existingstructure in the opening.
Products IncludedUltimate Glider
Certified Mull Installation MethodsMasonry Clips Jamb ScrewsStructural Brackets
Tributary and Span:
Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.
TributaryWidth
Span
TributaryWidth
TributaryWidth
TributaryWidth
Span
Ribbon Mull Stacked Mull
![Page 92: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/92.jpg)
Clad Mulling
Mull-92 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Section Details: Ultimate Glider Mulling Types
![Page 93: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/93.jpg)
Mull-93 19972255Marvin Signature Collection Architectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Section Details: Ultimate Glider Mulling Types (Continued)
Space Mulls and Solid Space Mulls are avail-able in 3/8", 1", 2", 3", 4" and 6" widths.
Marvin provides interior mull trim for mulls up to2".
![Page 94: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/94.jpg)
Clad Mulling
Mull-94 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Glider Mulling - Standard Frame Vertical (Ribbon or Stacked Assembly)
CN 30 36 40 46 50 56 60 70 80 90 100CN Frame OM 35 1/2 41 1/2 47 1/2 53 1/2 59 1/2 65 1/2 71 1/2 83 1/2 95 1/2 107 1/2 119 1/2
30 35 1/2
36 41 1/2DP 50
40 47 1/2
46 53 1/2DP 40
50 59 1/2DP 30
56 65 1/2 DP 20
60 71 1/2
Span
Tributary Width
![Page 95: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/95.jpg)
Mull-95 19972255Marvin Signature Collection Architectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Glider Mulling - 3/8" MRF, 1" LVL, 2" LVL (Vertical) (Ribbon or Stacked Assembly)
CN 30 36 40 46 50 56 60 70 80 90 100CN Frame OM 35 1/2 41 1/2 47 1/2 53 1/2 59 1/2 65 1/2 71 1/2 83 1/2 95 1/2 107 1/2 119 1/2
30 35 1/2
36 41 1/2
40 47 1/2
46 53 1/2DP 50
50 59 1/2
56 65 1/2
60 71 1/2
Span
Tributary Width
![Page 96: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/96.jpg)
Clad Mulling
Mull-96 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Glider Mulling - 3/8" Solid Space Mull (Vertical) (Ribbon or Stacked Assembly)
CN 30 36 40 46 50 56 60 70 80 90 100CN Frame OM 35 1/2 41 1/2 47 1/2 53 1/2 59 1/2 65 1/2 71 1/2 83 1/2 95 1/2 107 1/2 119 1/2
30 35 1/2
36 41 1/2 DP 50
40 47 1/2
46 53 1/2
50 59 1/2DP 40
56 65 1/2DP 30
60 71 1/2DP 20
Tributary Width
Span
![Page 97: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/97.jpg)
Mull-97 19972255Marvin Signature Collection Architectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Glider Mulling - 1" Solid Space Mull (Vertical) (Ribbon or Stacked Assembly)
CN 30 36 40 46 50 56 60 70 80 90 100CN Frame OM 35 1/2 41 1/2 47 1/2 53 1/2 59 1/2 65 1/2 71 1/2 83 1/2 95 1/2 107 1/2 119 1/2
30 35 1/2
36 41 1/2
40 47 1/2 DP 50
46 53 1/2
50 59 1/2
56 65 1/2
60 71 1/2DP 40 DP 30
Span
Tributary Width
![Page 98: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/98.jpg)
Clad Mulling
Mull-98 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Glider Mulling - 1" and 2" LVL (Horizontal) (Ribbon or Stacked Assembly)
CN 30 36 40 46 50 56 60CN Frame OM 35 1/2 41 1/2 47 1/2 53 1/2 59 1/2 65 1/2 71 1/2
30 35 1/2
36 41 1/2
40 47 1/2
46 53 1/2DP 50
50 59 1/2
56 65 1/2
60 71 1/2
66 77 1/2 DP 40
70 83 1/2
76 89 1/2 DP 30
80 95 1/2
86 101 1/2
90 107 1/2DP 20
96 113 1/2
Tributary Width
Span
![Page 99: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/99.jpg)
Mull-99 19972255Marvin Signature Collection Architectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Glider Mulling - Solid Space Mull (2", 3", 4" and 6") (Ribbon or Stacked Assembly)
CN 30 36 40 46 50 56 60 70 80 90 100CN Frame OM 35 1/2 41 1/2 47 1/2 53 1/2 59 1/2 65 1/2 71 1/2 83 1/2 95 1/2 107 1/2 119 1/2
30 35 1/2
36 41 1/2
40 47 1/2DP 50
46 53 1/2
50 59 1/2
56 65 1/2
60 71 1/2
Tributary Width
Span
![Page 100: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/100.jpg)
Clad Mulling
Mull-100 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
![Page 101: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/101.jpg)
Mull-101 19972255Marvin Signature Collection Architectural Detail Manual
General Mulling Information
Ver 2019.3 2019-07-29
Multi-High, Multi-Wide MullingMarvin offers a variety of mull options for many of the Marvin window and door projects. Some mulls can be done in the factory.Others would need to be done in the field. Some mulls create a certified assembly according to third-party testing.
Marvin Mull Options:Marvin-SuppliedStandard Mull: Two or more units mulled together directly without any reinforcement or space between the frames.
Reinforcement may be required either vertically or horizontally to meet structural design pressure ratings. 3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or field
assembly of the mullion.Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.
◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull Reinforcement: Laminated Veneered Lumber is used as a solid space mull.
◦ LVL is 1.7 to 1.9 times stronger than regular wood. ◦ 1" and 2" widths are available from Marvin.
Space Mull: Non-continuous blocks of wood are used to space units apart. ◦ 3/8", 1", 2", 3", 4" and 6" widths are available.
Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation of an existingstructure in the opening.
Field Supplied and Applied Tube Mull: Tube aluminum or steel used to reinforce mulled assemblies. Flat Mull: Flat Steel or Aluminum used to reinforce mulled assemblies.
NOTE: Multi-High Multi-Wide Assemblies with any side that exceed 72” in either direction will be shipped with a temporary blockingaround the entire perimeter of the assembly to provide support during shipping and handling.
Certified Mull Installation MethodsMasonry Clips Jamb ScrewsStructural Brackets
AnchoringSpecial considerations need to be made when installing mulled assemblies. Mullions create point loads that need to be
transferred to the rough opening. For Marvin standard, MRF, LVL, and space mulls, the ends of the mull need to be fastened oneach side of the splice with either jamb screws or brackets. Aluminum, steel and other structural mulls need to be anchoreddirectly to the rough opening or building structure.
Tributary and Span:Tributary Width - The area supported by the mullion. In the case of a vertical mull, this is equal to the sum of half of the width of eachunit on each side of the mull.Span - The length of the mullion
TributaryWidth
SpanTributary
Width
Span
Reinforcement
Rei
nfor
cem
ent
2 Wide 2 High 2 Wide 2 High
Multi-Wide Multi-High Mull
![Page 102: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/102.jpg)
General Mulling Information
Mull-102 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Multi-High Multi-Wide (Full Frame 3/8" Mull Reinforcement)Mullion Performance Charts
24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88485052 DP 50545658 DP 40606264 PG66 DP 3068707274 PG 40 DP 2576788082 DP 2084868890 PG 5092949698
100102104106108 PG 25110112114116118120
Span
Tributary Width
![Page 103: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/103.jpg)
Mull-103 19972255Marvin Signature Collection Architectural Detail Manual
General Mulling Information
Ver 2019.3 2019-07-29
Multi-High Multi-Wide (Narrow Frame 3/8" Mull Reinforcement)
24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 884850 DP 4052545658 DP 5060 DP 206264 DP 3066687072747678 DP 40808284
Tributary Width
Span
![Page 104: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/104.jpg)
General Mulling Information
Mull-104 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Multi-High Multi-Wide (Full Frame 1" LVL)
24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 884850 DP 505254 DP 405658 DP 656062 DP 306466687072747678 DP 5080 DP 40 DP 30 DP 20828486889092949698
100102104106108110112114116118120
Span
Tributary Width
![Page 105: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/105.jpg)
Mull-105 19972255Marvin Signature Collection Architectural Detail Manual
General Mulling Information
Ver 2019.3 2019-07-29
Multi-High Multi-Wide 2" LVL (4 9/16")
24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88485052545658 DP 65606264666870727476788082 DP 50848688 DP 4090929496 DP 3098
100102104106 DP 20108110112114116118120
Span
Tributary Width
![Page 106: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/106.jpg)
General Mulling Information
Mull-106 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
![Page 107: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/107.jpg)
Mull-107 19972255Marvin Signature Collection Architectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Inswing French Door Mull TypesMarvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Ultimate Inswing French Door product.
Mull Types:Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames. 2" LVL Mull: Laminated Veneered Lumber is used as a solid space mull.
Products IncludedUltimate Inswing French DoorUltimate Inswing French Door IZ3
Certified Mull Installation MethodsMasonry Clips Jamb ScrewsStructural Brackets
Tributary and Span:Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.
TributaryWidth
Span
![Page 108: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/108.jpg)
Clad Mulling
Mull-108 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Section Details: Ultimate Inswing French Door Mulling Types
![Page 109: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/109.jpg)
Mull-109 19972255Marvin Signature Collection Architectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Section Details: Ultimate Inswing French Door Mulling Types (Continued)
![Page 110: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/110.jpg)
Clad Mulling
Mull-110 19972255Marvin Signature Collection Architectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Inswing French Door Mulling - All Mull Types
NOTE: Includes UIFD with transoms of 1 frame and 1 sash (French Door Transoms, UDHG2 Transoms, Ultimate Direct GlazeTransoms or Ultimate Casement Transoms.
48 50 52 54 56 58 60 62.75
60.625 DP 50
72.625
PG 40
84.625
96.625 DP 30
110.719
DP 20
125.813
Span
Tributary Width
![Page 111: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/111.jpg)
Mull-111 19972255Marvin Signature Collection Architectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Outswing French Door Mull TypesMarvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Ultimate Outswing French Door product.
Mull Types:Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames. 2" LVL Mull: Laminated Veneered Lumber is used as a solid space mull.
Products IncludedUltimate Outswing French DoorUltimate Outswing French Door IZ3
Certified Mull Installation MethodsMasonry Clips Jamb ScrewsStructural Brackets
Tributary and Span:
Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.
TributaryWidth
Span
![Page 112: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/112.jpg)
Clad Mulling
Mull-112 19972255Marvin Signature CollectionArchitectural Detail Manual
Ver 2019.3 2019-07-29
Section Details: Ultimate Outswing French Door Mulling Types
![Page 113: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/113.jpg)
Mull-113 19972255Marvin Signature Collection Architectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Section Details: Ultimate Outswing French Door Mulling Types (Continued)
![Page 114: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/114.jpg)
Clad Mulling
Mull-114 19972255Marvin Signature CollectionArchitectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Outswing French Door Mulling - All Mull Types
NOTE: Includes UOFD with transoms of 1 frame and 1 sash (French Door Transoms, UDHG2 Transoms, Ultimte Direct GlazeTransoms or Ultimate Casement Transoms.
48 50 52 54 56 58 60 62.75
60.625 DP 50
72.625
PG 40
84.625
96.625 DP 30
110.719
DP 20
125.813
Span
Tributary Width
![Page 115: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/115.jpg)
Mull-115 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Sliding French Door Mull TypesMarvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Ultimate Sliding French Door product.
Mull Types:Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames. 2" LVL Mull: Laminated Veneered Lumber is used as a solid space mull.
Products IncludedUltimate Sliding French DoorUltimate Sliding French Door IZ3
Certified Mull Installation MethodsMasonry Clips Jamb ScrewsStructural Brackets
Tributary and Span:
Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.
TributaryWidth
Span
![Page 116: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/116.jpg)
Clad Mulling
Mull-116 19972255Marvin Signature CollectionArchitectural Detail Manual
Ver 2019.3 2019-07-29
Section Details: Ultimate Sliding French Door Mulling Types
![Page 117: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/117.jpg)
Mull-117 19972255Marvin Signature CollectionArchitectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Section Details: Ultimate Sliding French Door Mulling Types (Continued)
![Page 118: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/118.jpg)
Clad Mulling
Mull-118 19972255Marvin Signature CollectionArchitectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Sliding French Door Mulling - All Mull Types
NOTE: Includes USFD with transoms of 1 frame and 1 sash (French Door Transoms, UDHG2 Transoms, Ultimate Direct GlazeTransoms or Ultimate Casement Transoms.
48 50 52 54 56 58 60 62.75
60.625 DP 50
72.625
PG 40
84.625
96.625 DP 30
110.719
DP 20
125.813
Span
Tributary Width
![Page 119: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/119.jpg)
Mull-119 19972255Marvin Signature Collection Architectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Ultimate Sliding Patio Door Mull TypesMarvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Ultimate Sliding Patio Door product.
Mull Types:Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames. 2" LVL Mull: Laminated Veneered Lumber is used as a solid space mull.
Products IncludedUltimate Sliding Patio Door
Certified Mull Installation MethodsMasonry Clips Jamb ScrewsStructural Brackets
Tributary and Span:
Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.
TributaryWidth
Span
![Page 120: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/120.jpg)
Clad Mulling
Mull-120 19972255Marvin Signature CollectionArchitectural Detail Manual
Ver 2019.3 2019-07-29
Section Details: Ultimate Sliding Patio Door Mulling Types
![Page 121: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/121.jpg)
Mull-121 19972255Marvin Signature Collection Architectural Detail Manual
Clad Mulling
Ver 2019.3 2019-07-29
Section Details: Ultimate Sliding Patio Door Mulling Types (Continued)
![Page 122: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/122.jpg)
Clad Mulling
Mull-122 19972255Marvin Signature CollectionArchitectural Detail Manual
Ver 2019.3 2019-07-29
Ultimate Sliding Patio Door Mulling - All Mull Types
NOTE: Includes USPD with transoms of 1 frame and 1 sash (French Door Transoms, UDHG2 Transoms, Ultimate Direct GlazeTransoms or Ultimate Casement Transoms.
48 50 52 54 56 58 60 62.75
60.625 DP 50
72.625
PG 40
84.625
96.625 DP 30
110.719
DP 20
125.813
Span
Tributary Width
![Page 123: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/123.jpg)
Mull-123 19972255Marvin Modern Collection
Architectural Detail Manual
Mulling
Ver 2019.3 2019-07-29
Modern Casement Mull TypesThis document is a compilation of mulling options for the Modern Casement and Awning products.
Mull Types:Standard Mull: 2 or more units mulled directly together with the standard 1/2" x 2 1/4" Aluminum; requires standard interior and
exterior mull covers. 1/2" x 2 1/2” Steel: 2 or more units mulled directly together with 1/2" x 2 1/2” Flat steel; requires standard interior and exterior mull
covers. 1/2” x 4” Steel: 2 or more units mulled directly together with 1/2” x 4” Flat steel; requires standard exterior and 4” interior mull
cover. 2” x 4” Tube Steel: 2 or more units mulled together with 2” x 4” Tube steel creates a 1 1/2” space between the units requiring
different interior and exterior covers. 4 1/2” Stud Pocket: Exterior and interior covers to spread the units 4 1/2” apart.
NOTE: Aluminum mull supplied by Marvin. All other structure is supplied by others.
Products IncludedModern Casement Crank OutModern Casement Push OutModern Awning Crank OutModern Awning Push Out
Certified Mull Installation Methods Jamb Screws
Tributary and Span:Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.Tributary
Width
Span
TributaryWidth
TributaryWidth
TributaryWidth
Span
Ribbon Mull Stacked Mull
![Page 124: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/124.jpg)
Mulling
Mull-124 19972255Marvin Modern Collection
Architectural Detail Manual
Ver 2019.3 2019-07-29
Section Details: Modern Casement/Awning Standard Mulling Types
Head Jamb and Sill Jambs
15/16" Dual Pane Glass
7/16″(11)
5 9/16″(141)
1 1/8″(29)
2 27/32″(73)
7/16″(11)
5 9/16″(141)
1 1/8″(29)
2 27/32″(73)
4 11/16″(119)
4 11/16″(119)
1 17/32″(39)
1 17/32″(39)
![Page 125: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/125.jpg)
Mull-125 19972255Marvin Modern Collection
Architectural Detail Manual
Mulling
Ver 2019.3 2019-07-29
Modern Casement/Awning Mulling - Standard Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96
60
62 DP40
64
66
68
70
72 PG40
74
76
78
80
82
84
86
88
90
92
94
96
98
100 DP40
102
Tributary Width
Span
![Page 126: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/126.jpg)
Mulling
Mull-126 19972255Marvin Modern Collection
Architectural Detail Manual
Ver 2019.3 2019-07-29
![Page 127: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/127.jpg)
Mull-127 19972255Marvin Modern Collection
Architectural Detail Manual
Mulling
Ver 2019.3 2019-07-29
Modern Direct Glaze Mull TypesThis document is a compilation of mulling options for the Modern Direct Glaze product.
Mull Types:Standard Mull: 2 or more units mulled directly together with the standard 1/2" x 2 1/4" Aluminum; requires standard interior and
exterior mull covers. 1/2" x 2 1/2” Steel: 2 or more units mulled directly together with 1/2" x 2 1/2” Flat steel; requires standard interior and exterior mull
covers. 1/2” x 4” Steel: 2 or more units mulled directly together with 1/2” x 4” Flat steel; requires standard exterior and 4” interior mull
cover. 2” x 4” Tube Steel: 2 or more units mulled together with 2” x 4” Tube steel creates a 1 1/2” space between the units requiring
different interior and exterior covers. 4 1/2” Stud Pocket: Exterior and interior covers to spread the units 4 1/2” apart.
NOTE: Aluminum mull supplied by Marvin. All other structure is supplied by others.
Products IncludedModern Direct Glaze PolygonModern Direct Glaze Rectangle
Certified Mull Installation Methods Jamb Screws
Tributary and Span:Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.
TributaryWidth
Span
TributaryWidth
TributaryWidth
TributaryWidth
Span
Ribbon Mull Stacked Mull
![Page 128: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/128.jpg)
Mulling
Mull-128 19972255Marvin Modern Collection
Architectural Detail Manual
Ver 2019.5 2019-10-28
Section Details: Modern Direct Glaze Standard Mulling Types
2 27/32"(72)
2 27/32"(73)
2 27/32"(73)
Direct Glaze RectangleJambs
Direct Glaze RectangleHead Jamb and Sill
2 27/32"(73)
2 27/32"(72)
2 27/32"(73)
2 27/32"(73)
Direct Glaze PolygonJambs
Direct Glaze - PolygonHead Jamb and Sill
2 27/32"(73)
![Page 129: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/129.jpg)
Mull-129 19972255Marvin Modern Collection
Architectural Detail Manual
Mulling
Ver 2019.3 2019-07-29
Modern Direct Glaze Mulling - Standard Mull (Ribbon or Stacked Assembly)
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100-144
72
74
76
78 PG4080
82 DP4084
86
88
90
92 DP3594 DP3096
98
100
102
104 DP40106 DP30 DP25108 DP35110
112 DP20114
116
118
120
122
124
126
128
130
132
134
136
138
140
142
Tributary Width
Span
![Page 130: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/130.jpg)
Mulling
Mull-130 19972255Marvin Modern Collection
Architectural Detail Manual
Ver 2019.3 2019-07-29
![Page 131: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/131.jpg)
Mull-131 19972255Marvin Modern Collection
Architectural Detail Manual
Mulling
Ver 2021.1 2021-02-22
Modern Swinging Doors Mull TypesThis document is a compilation of mulling options for the Modern Inswing and Outswing Door products.
Mull Types:Standard Mull: 2 or more units mulled directly together with the standard 1/2" x 2 1/4" Aluminum; requires standard interior and
exterior mull covers. 1/2" x 2 1/2” Steel: 2 or more units mulled directly together with 1/2" x 2 1/2” Flat steel; requires standard interior and exterior mull
covers. 1/2” x 4” Steel: 2 or more units mulled directly together with 1/2” x 4” Flat steel; requires standard exterior and 4” interior mull
cover. 2” x 4” Tube Steel: 2 or more units mulled together with 2” x 4” Tube steel creates a 1 1/2” space between the units requiring
different interior and exterior covers. 4 1/2” Stud Pocket: Exterior and interior covers to spread the units 4 1/2” apart.
NOTE: Aluminum mull supplied by Marvin. All other structure is supplied by others.
Products IncludedModern Inswing DoorModern Outswing Door
Certified Mull Installation Methods Jamb Screws
Tributary and Span:Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.
TributaryWidth
Span
TributaryWidth
TributaryWidth
TributaryWidth
Span
Ribbon Mull Stacked Mull
![Page 132: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/132.jpg)
Mulling
Mull-132 19972255Marvin Modern Collection
Architectural Detail Manual
Ver 2021.1 2021-02-22
Section Details: Modern Inswing Door Standard Mulling Types
2 27/32"(72)
5 25/32"(147)
2 27/32"(73)
Direct Glaze Rectangle Sidelite /Inswing Door
Direct Glaze Rectangle OverInswing Door
2 27/32"(73)
5 25/32"(147)
4 7/32"(107)
4 7/32"(107)
5 25/32"(147)
Awning OverInswing Door
Casement Sidelite /Inswing Door
8 23/32"(222)
2 27/32"(73)
Inswing Door /Inswing Door
![Page 133: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/133.jpg)
Mull-133 19972255Marvin Modern Collection
Architectural Detail Manual
Mulling
Ver 2021.1 2021-02-22
Section Details: Modern Outswing Door Standard Mulling Types
2 27/32"(73)
5 25/32"(147)
5 25/32"(147)
2 27/32"(73)
2 27/32"(73)
7 1/8"(181)
Direct Glaze Rectangle OverOutswing Door
7 1/8"(181)
2 27/32"(73)
Awning OverOutswing Door
Direct Glaze Rectangle Sidelite /Outswing Door
Casement Sidelite /Outswing Door
2 27/32"(73)
8 23/32"(222)
Outswing /Outswing Door
Jambs
![Page 134: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/134.jpg)
Mulling
Mull-134 19972255Marvin Modern Collection
Architectural Detail Manual
Ver 2021.1 2021-02-22
Modern Swinging Doors Mulling - Standard Mull (Ribbon or Stacked Assembly)
* Inswing XX stacked mull excluded as it only meets PG30.** Inswing XX stacked mull with performance sill excluded as it only meets DP30.
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100-1447274767880 *DP40 (Performance Sill)82 *PG40 (Performance Sill)84 PG30 (Low Profile Sill)86889092 **DP3594 DP309698
100 DP30102 *DP40 (Performance Sill)104106108 **DP35 DP25110112114 DP20116118120122124126128130132134136138140142
Tributary Width
Span
DP30 (Low Profile Sill)
DP30 (Low Profile Sill)
![Page 135: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/135.jpg)
Mull-135 19972255Marvin Modern Collection
Architectural Detail Manual
Mulling
Ver 2019.3 2019-07-29
Modern Additional Steel Mull TypesThis document is a compilation of additional steel mulling options for the Modern window products.
Mull Types: 1/2" x 2 1/2” Steel: 2 or more units mulled directly together with 1/2" x 2 1/2” Flat steel; requires standard interior and exterior mull
covers. 1/2” x 4” Steel: 2 or more units mulled directly together with 1/2” x 4” Flat steel; requires standard exterior and 4” interior mull
cover. 2” x 4” Tube Steel: 2 or more units mulled together with 2” x 4” Tube steel creates a 1 1/2” space between the units requiring
different interior and exterior covers. 4 1/2” Stud Pocket: Exterior and interior covers to spread the units 4 1/2” apart.
NOTE: Aluminum mull supplied by Marvin. All other structure is supplied by others.
Products IncludedModern CasementModern Direct Glaze PolygonModern Direct Glaze Rectangle
Certified Mull Installation Methods Jamb Screws
Tributary and Span:Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.
TributaryWidth
Span
TributaryWidth
TributaryWidth
TributaryWidth
Span
Ribbon Mull Stacked Mull
![Page 136: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/136.jpg)
Mulling
Mull-136 19972255Marvin Modern Collection
Architectural Detail Manual
Ver 2021.6 2021-12-20
Section Details: Modern Additional Steel Mulling Types
NOTE: Mull Certification includes Direct Glaze, Casement/Awning, Inswing and Outswing door products.Tributary spans are limited based on individual maximum unit sizeStandard Aluminum Mull provided by Marvin. All other structure supplied by others.
2 27/32"(72)
2 27/32"(73)
1/2" X 2 1/4" Aluminum Mull
2 27/32"(72)
2 27/32"(73)
1/2" X 4" Flat Steel Mull
2 5/8"(67)
4 11/32"(110)
4 11/32"(111)
2" X 4" Tube Steel Mull
2 1/8"(54)
1 1/2"(38)
1 1/2"(38)
2 27/32"(72)
2 27/32"(73)
1/2" X 2 1/2" Flat Steel Mull
![Page 137: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/137.jpg)
Mull-137 19972255Marvin Modern Collection
Architectural Detail Manual
Mulling
Ver 2021.6 2021-12-20
Section Details: Modern Additional Steel Mulling Types
NOTE: Mull Certification includes Direct Glaze, Casement/Awning, Inswing and Outswing door products.Tributary spans are limited based on individual maximum unit sizeStandard Aluminum Mull provided by Marvin. All other structure supplied by others.
5 5/8"(143)7 11/32"
(186) 7 11/32"(187)
4 1/2" Stud Pocket Mull With Wood
5 1/8"(130)
3 1/2"(89)
7 29/32"(201)
4 1/2"(114)
5 5/8"(143)7 11/32"
(186) 7 11/32"(187)
4 1/2" Stud Pocket Mull With Tube Steel
5 1/8"(130)
3 1/2"(89)
7 29/32"(201)
4 1/2"(114)
![Page 138: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/138.jpg)
Mulling
Mull-138 19972255Marvin Modern Collection
Architectural Detail Manual
Ver 2019.6 2019-12-16
Modern Window Steel Mulling - 1/2" x 2 1/2" Flat Steel Mull (Ribbon or Stacked Assembly)
24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 144
60
62
64
66
68
70
72
74
76
78 DP4080
82
84
86 PG50 (Certified)88 CW40 (Certified)90
92
94
96
98
100
102 DP35104
106 DP30108
110 DP35112 DP25114 PG50 (Certified) DP30116 CW40 (Certified)118
120
122
124
126
128 DP35130
132
134
136
138
140
142
144
Tributary Width
Span
![Page 139: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/139.jpg)
Mull-139 19972255Marvin Modern Collection
Architectural Detail Manual
Mulling
Ver 2019.6 2019-12-16
Modern Window Steel Mulling - 1/2" x 4" Flat Steel Mull (Ribbon or Stacked Assembly)
24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 144
60
62
64
66
68
70
72
74
76
78 DP4080
82
84
86 PG50 (Certified)88 CW40 (Certified)90
92
94
96
98
100
102 DP35104
106 DP30108
110 DP35112 DP25114 PG50 (Certified) DP30116 CW40 (Certified)118
120
122
124
126
128 DP35130
132
134
136
138
140
142
144
Tributary Width
Span
![Page 140: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/140.jpg)
Mulling
Mull-140 19972255Marvin Modern Collection
Architectural Detail Manual
Ver 2019.6 2019-12-16
Modern Window Steel Mulling - 2" x 4" Tube Steel Mull (Ribbon or Stacked Assembly)
36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 144
60
62
64
66
68 PG40 (Certified)70 CW40 (Certified) DP4072
74
76
78
80
82
84
86
88
90
92
94
96
98
100
102
104
106 DP35108
110
112
114
116
118
120
122
124
126
128
130
132
134
136 DP40 DP35 DP30 DP25138
140
142
144
146
148
150
152
154
156
158
160
162
164
166
168
170
172
174
176
178
180
182
184
186
188
190
192
Tributary Width
Span
![Page 141: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/141.jpg)
Mull-141 19972255Marvin Modern Collection
Architectural Detail Manual
MullingModern Window Steel Mulling - 1/2" x 2 1/2" Flat Steel Mull (Multi-High, Multi-Wide Assembly)
24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 144
60 DP4062 DP35 DP3064
66 PG50 (Certified)68 CW40 (Certified)70
72
74
76
78 DP2580 DP4082 DP3084 DP3586
88
90
92
94
96
98
100
102
104
106
108
110
112
114
116
118
120
122
124
Tributary Width
Span
![Page 142: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/142.jpg)
Mulling
Mull-142 19972255Marvin Modern Collection
Architectural Detail Manual
Modern Window Steel Mulling - 1/2" x 4" Flat Steel Mull (Multi-High, Multi-Wide Assembly)
36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 144
60
62
64
66
68 DP4070
72
74
76
78
80 PG40 (Certified)82 CW40 (Certified)84
86
88
90
92 DP3594
96
98
100
102
104
106
108
110
112
114
116
118 DP40 DP35 DP30 DP25120
122
124
126
128
130
132
134
136
138
140
142
144
146
148
150
152
154
156
158
160
162
164
166
168
170
172
174
Tributary Width
Span
![Page 143: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/143.jpg)
Mull-143 19972255Marvin Modern Collection
Architectural Detail Manual
MullingModern Window Steel Mulling - 2" x 4" Tube Steel Mull (Multi-High, Multi-Wide Assembly)
36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 144
60
62
64
66
68 PG40 (Certified)70 DP4072
74
76
78
80
82
84
86
88
90
92
94
96
98
100
102
104
106 DP35108
110
112
114
116
118
120
122
124
126
128
130
132
134
136 DP40 DP35 DP30 DP25138
140
142
144
146
148
150
152
154
156
158
160
162
164
166
168
170
172
174
176
178
180
182
184
186
188
190
192
Tributary Width
Span
![Page 144: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/144.jpg)
Mulling
Mull-144 19972255Marvin Modern Collection
Architectural Detail Manual
Ver 2021.1 2021-02-22
Modern Swinging Doors Mulling - 2 1/2" Steel Mull (Ribbon or Stacked Assembly)
* Inswing XX stacked mull excluded as it only meets PG30.** Inswing XX stacked mull with performance sill excluded as it only meets DP30.
24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 1446062646668707274
76 *PG40 (Performance Sill)78 PG30 (Low Profile Sill) *DP4080 DP3082 Availability of CW performance on O configuration only84
86
889092949698100
102 **DP35104106108
110 **DP35112 DP25114 *PG40 (Performance Sill)116 PG30 (Low Profile Sill)118120122124126
128 **DP35 Max sizes based on 144" X 120" O door + DG with 141.375 long dimension130 Vertical Mull132 Max Span = 120" (certified height)134 Max Tributary = 144" ((2)144" wide O units)136 Horizontal Mull138 Max Span = 144" (widest O)140 Max Tributary = 130.6875" (120" tall door + 141.375 tall DG)142144
Tributary Width
Span
DP30
![Page 145: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/145.jpg)
Mull-145 19972255Marvin Modern Collection
Architectural Detail Manual
Mulling
Ver 2021.1 2021-02-22
Modern Swinging Doors Mulling - 4" Steel Mull (Ribbon or Stacked Assembly)
* Inswing XX stacked mull excluded as it only meets PG30.** Inswing XX stacked mull with performance sill excluded as it only meets DP30.
24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 14460626466687072747678808284 *DP4086 *PG40 (Performance Sill) DP3088 PG30 (Low Profile Sill)90929496 Availability of CW performance on O configuration only98100102104106108110112114116118120122 **DP35124
126
128
130 DP30132
134136138140 DP25141
Tributary Width
![Page 146: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/146.jpg)
Mulling
Mull-146 19972255Marvin Modern Collection
Architectural Detail Manual
Ver 2021.1 2021-02-22
Modern Swinging Doors Mulling - 2" x 4" Tube Steel Mull (Ribbon or Stacked Assembly)
* Inswing XX stacked mull excluded as it only meets PG30.** Inswing XX stacked mull with performance sill excluded as it only meets DP30.NOTE: Tube Steel not recommended with Operating Outswing Door mulls.
36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 ## ## ## ## ## ## 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 1446062646668 *PG40 (Performance Sill)70 PG30 (Low Profile Sill) *DP4072 DP3074767880 Availability of CW performance on O configuration only828486889092949698
100102104
106 **DP35108110112114116118120122124
126 *DP40 **DP35 DP30 DP25128 DP30130132134
136138140142144
Tributary Width
Span
![Page 147: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/147.jpg)
Mull-147 19972255Marvin Modern Collection
Architectural Detail Manual
MullingModern Door Steel Mulling - 1/2" x 2 1/2" Flat Steel Mull (Multi-High, Multi-Wide Assembly)
24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 144
60 *DP4062 **DP35 DP3064
66 *PG40 (Performance Sill)68 PG30 (Low Profile Sill)70 Availability of CW performance on O configuration only72
74
76
78 DP2580 *DP4082 DP3084 **DP3586
88
90
92
94
96
98
100
102
104
106
108
110
112
114
116
118
120
122
124
Span
Tributary Width
![Page 148: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/148.jpg)
Mulling
Mull-148 19972255Marvin Modern Collection
Architectural Detail Manual
Modern Door Steel Mulling - 1/2" x 4" Flat Steel Mull (Multi-High, Multi-Wide Assembly)
36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 14460626466
68 *DP4070 DP3072747678
80 *PG40 (Performance Sill)82 PG30 (Low Profile Sill)848688 Availability of CW performance on O configuration only90
92 **DP35949698
100102104106108110112114116
118 *DP40 **DP35 DP30 DP25120 DP30122
124
126
128130132134136138140142144146148150152154156158160162164166168170172174
Tributary Width
Span
![Page 149: General Mulling Information](https://reader033.vdocuments.mx/reader033/viewer/2022051513/627ec8f58364b514104c91ca/html5/thumbnails/149.jpg)
Mull-149 19972255Marvin Modern Collection
Architectural Detail Manual
MullingModern Door Steel Mulling - 2" x 4" Tube Steel Mull (Multi-High, Multi-Wide Assembly)
36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 14460626466
68 *PG40 (Performance Sill)70 PG30 (Low Profile Sill) *DP4072 DP3074
767880828486889092949698100102104
106 **DP35108110112114116118120122124126128130132134
136 *DP40 **DP35 DP30 DP25138 DP30140142144146148150152154156158160162164166168170172174176178180182184186188190192
Tributary Width
Span