general features - precimeasure controls specifications.pdf• the wti instruments have a built in...

34
www.precimeasure.com PRECIMEASURE The fully sealed liquid expansion in the system provides a self powered indication and operation to the instruments, and does not require any trimming or other periodic adjustments. Instruments are fully compensated for ambient temperature. The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. The WTIs are provided with gradient adjustment through a shunt for CT secondary input (1A to 5A). Instrument cases are aluminium die casted and polyester powder coated. Each instrument has anti vibration mountings and are provided with projection mounting clamps. A maximum pointer facility is provided, can be reset from outside. All switch contacts are potential free micro switches MODEL - 1005/1005A DIAL TYPE THERMOMETER SPECIFICATIONS Model : 1005 Model : 1005A Temperature Range 0 -150 0 C, 0 -160 0 C, 30 -150 0 C, -20 to 140 0 C 0 -150 0 C, 0 -160 0 C, 30 -150 0 C, -20 to 140 0 C Dial Size 150mm (6”) Round 150mm (6”) Round Dial angular Sweep 270 0 270 0 Dial Graduation 1 0 C 1 0 C Accuracy Class ±1% of FSD ±1% of FSD Max. No. of Switches 5 5 Switching Range 15% - 85% 15% - 85% Contact Rating 3A @ 250V AC/DC Magnetic Blowout Micro switch 15A @ 250V AC 0.5A @ 250V DC Standard Micro switch Switch Differential S1 & S2: 3°C to 9°C (6±3 0 C)Fixed S3 to S5: 8°C to 40 0 C Adjustable. S1 & S2: 3°C to 9 0 C (6±3 0 C)Fixed S3 to S5: 8 0 C to 40 0 C Adjustable. Switching Accuracy ±2.5 0 C of Set Value ±2.5 0 C of Set Value Remote Repeater Available (Potentiometer Output) Available (Potentiometer Output) Max. Capillary Length Up to 25 Mtrs Up to 25 Mtrs Switch Test Knob Available Available Electrical Connection Press Fit Wago Type Press Fit Wago Type Degree of Protection IP – 55(IEC - 60529) IP – 55(IEC - 60529) High Voltage Test 2.5 KV AC, 50Hz/60Hz for 1 minute; all Terminals to ground 2.5 KV AC, 50Hz/60Hz for 1 minute; all Terminals to ground Electrical entry M20 - 3Nos M20 - 3Nos Cable Gland Optional Optional Thermometer Pocket Optional Optional Remote Repeater 96 Sq 1005/1005A General Features STANDARD OTI / WTI SPECIFICATIONS Type 4 digits, 0.5’’ Seven Segments LED’s Auxillary Supply 90 – 260V AC/DC Resolution 0.1 0 C Degree of protection of enclosure IP 20 Operating Temperature Range 0 0 C to 60 0 C Signal output 4 sets of 4 - 20mA DC Optional RS 485 Cutout dimension 92 Sq. mm DIAL TYPE

Upload: others

Post on 18-Mar-2020

44 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

Precimeasure

• Thefullysealedliquidexpansioninthesystemprovidesaselfpoweredindicationandoperationtotheinstruments,anddoesnotrequireanytrimmingorotherperiodicadjustments.

• Instrumentsarefullycompensatedforambienttemperature.• TheWTIinstrumentshaveabuiltinThermalimagingsystemfortransformer’shotspotindication.• TheWTIsareprovidedwithgradientadjustmentthroughashuntforCTsecondaryinput(1Ato5A).• Instrument cases are aluminium die casted and polyester powder coated. Each instrument hasantivibrationmountingsandareprovidedwithprojectionmountingclamps.

• Amaximumpointerfacilityisprovided,canberesetfromoutside.• Allswitchcontactsarepotentialfreemicroswitches

MODEL - 1005/1005ADIAL TYPE THERMOMETER

SpecificationS Model : 1005 Model : 1005aTemperatureRange 0-1500C,0-1600C,30-1500C,

-20to1400C0-1500C,0-1600C,30-1500C,-20to1400C

DialSize 150mm(6”)Round 150mm(6”)RoundDialangularSweep 2700 2700

DialGraduation 10C 10CAccuracyClass ±1%ofFSD ±1%ofFSDMax.No.ofSwitches 5 5SwitchingRange 15%-85% 15%-85%ContactRating 3A @ 250V AC/DC

Magnetic Blowout Micro switch15A @ 250V AC 0.5A @ 250V DCStandard Micro switch

SwitchDifferential S1&S2:3°Cto9°C(6±30C)FixedS3toS5:8°Cto400CAdjustable.

S1&S2:3°Cto90C(6±30C)FixedS3toS5:80Cto400CAdjustable.

SwitchingAccuracy ±2.50CofSetValue ±2.50CofSetValueRemoteRepeater Available(PotentiometerOutput) Available(PotentiometerOutput)Max.CapillaryLength Upto25Mtrs Upto25MtrsSwitchTestKnob Available AvailableElectricalConnection PressFitWagoType PressFitWagoTypeDegreeofProtection IP–55(IEC-60529) IP–55(IEC-60529)HighVoltageTest 2.5KVAC,50Hz/60Hzfor

1minute;allTerminalstoground2.5KVAC,50Hz/60Hzfor1minute;allTerminalstoground

Electricalentry M20-3Nos M20-3Nos

CableGland Optional Optional

ThermometerPocket Optional Optional

Remote Repeater 96 Sq

1005/1005A

General features

STANDARD OTI / WTI

SpecificationS

Type 4digits,0.5’’SevenSegmentsLED’s

AuxillarySupply 90–260VAC/DC

Resolution 0.10C

Degreeofprotectionofenclosure IP20

OperatingTemperatureRange 00Cto600C

Signaloutput 4setsof4-20mADC

OptionalRS485

Cutoutdimension 92Sq.mm

DIA

L TY

PE

Page 2: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

1. Protectionclass: IP55asperIEC60529CAT2.

2. ColdandDryTest: -40°Cto+70°C

3. VibrationTest: Amplitude1mm,frequency50Hz,

1Hr/X,Y,Zaxis

4. SaltSprayTest: Forpolyesterpowdercoatingand

SS304Armourfor500HrsasperDIN50021Standard

5. MicroSwitchratingTest: a)ML-1005:

3A@250VAC&3A@250VDC

b)ML-1005A:15A@250VAC&0.5A@250VDC

type tested forModel 1005 /1005a TypeofInstrument OTI/WTIRange R1.0-150°C

R2.0-160°CR3.30-150°CR4.-20to140°C(otherrangesonrequest)

No.ofSwitches S2-2switchesS3-3switchesS4-4switchesS5-5switches

SwitchConfiguration L-NormallyopencontactL2-Changeovercontact

CapillaryLength C1-1mtsC2-2mts.......uptoC25-25mts

UnionType U1-1/2“BSPMaleU2-3/4”BSPMaleU3-1”BSPMaleU4-1/2”BSPFemaleU5-3/4”BSPFemale

Repeater Y-RequriedN-NotRequired

IfWTIpleasespecify TransformerCTSecondaryoutput..................(1Ato5A)SimulatedTemperatureriseovertopoil...........(5°Cto30°C)

ordering information

Note:WTIGradientisfactoryset.Ifrequiredcustomercanadjustasperrequirement.

SampleOrderingInformation:1005\WTI\R3\S2\L2\C2\U1\Y\...........Amps...............°C

Registered Office & Works :No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. INdIa

Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–[email protected]

Branch Office & Works :No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. INdIa

Phone : + 91-44-2250 0191 / 2250 0175Fax : + 91-44-2250 0175E-Mail : sales–[email protected]

PRecimeasuRe cOntROls Pvt. ltd.

Western india Region Office :Mobile : 09377561070E-Mail : [email protected]

Page 3: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

Precimeasure

• Thefullysealedliquidexpansioninthesystemprovidesaselfpoweredindicationandoperationtotheinstruments,anddoesnotrequireanytrimmingorotherperiodicadjustments.

• Instrumentsarefullycompensatedforambienttemperature.• TheWTIinstrumentshaveabuiltinThermalimagingsystemfortransformer’shotspotindication.• TheWTIsareprovidedwithgradientadjustmentthroughashuntforCTsecondaryinput(1Ato5A).• embedded pt-100 sensors in the sensing bulb of the local oti/ Wti provide for a master

indication.• CurrentConverterUnit(CCU)ismountedinsidetheLocalOTI/WTI,TheoutputfromwhichcanbeconnectedtoremoteindicatororSCADAareacombinationofboth.

• FortheWTIsadditionalWindingtemperaturesimulatorisprovided• Instrument cases are aluminium die casted and polyester powder coated. Each instrument hasantivibrationmountingsandareprovidedwithprojectionmountingclamps.

• Amaximumpointerfacilityisprovided,canberesetfromoutside.• Allswitchcontactsarepotentialfreemicroswitches

MODEL - 1005H/1005AHDIAL TYPE THERMOMETER

SpecificationS Model : 1005H Model : 1005aHTemperatureRange 0-1500C,0-1600C,30-1500C,

-20to1400C0-1500C,0-1600C,30-1500C,-20to1400C

DialSize 150mm(6”)Round 150mm(6”)RoundDialangularSweep 2700 2700

DialGraduation 10C 10CAccuracyClass ±1%ofFSD ±1%ofFSDMax.No.ofSwitches 5 5SwitchingRange 15%-85% 15%-85%ContactRating 3A @ 250V AC/DC

Magnetic Blowout Micro switch15A @ 250V AC0.5A @ 250V DCStandard Micro switch

SwitchDifferential S1&S2:3°Cto9°C(6±30C)FixedS3toS5:8°Cto400CAdjustable.

S1&S2:3°Cto90C(6±30C)FixedS3toS5:80Cto400CAdjustable.

SwitchingAccuracy ±2.50CofSetValue ±2.50CofSetValueRemoteindicator Available/4-20mA/RS-485 Available/4-20mA/RS-485Max.CapillaryLength Upto25Mtrs. Upto25Mtrs.SwitchTestKnob Available AvailableElectricalConnection PressFitWagoType PressFitWagoTypeDegreeofProtection IP–55(IEC-60529) IP–55(IEC-60529)HighVoltageTest 2.5KVAC,50Hz/60Hzfor1

minute;Switchconnection&C.T.Terminaltoground.CCUoutput0.5KVAC50Hz/60Hzfor1minute

2.5KVAC,50Hz/60Hzfor1minute;Switchconnection&C.T.Terminaltoground.CCUoutput0.5KVAC50Hz/60Hzfor1minute

Electricalentry M20-3Nos M20-3Nos

CableGland Optional Optional

ThermometerPocket Optional OptionalRemote indicator 96 Sq

ML : 1005H/1005AH

General featuresHybrid OTI / WTI

SpecificationS

Type 4digits,0.5’’SevenSegmentsLED’s

AuxillarySupply 90–260VAC/DC

Resolution 0.10C

Degreeofprotectionofenclosure IP20

OperatingTemperatureRange 00Cto600C

Signaloutput 4setsof4-20mADC

OptionalRS485

Cutoutdimension 92Sq.mm

DIA

L TY

PE

Page 4: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

1. Protectionclass: IP55asperIEC60529CAT2.

2. ColdandDryTest: -40°Cto+70°C

3. VibrationTest: Amplitude1mm,frequency50Hz,

1Hr/X,Y,Zaxis

4. SaltSprayTest: Forpolysterpowdercoatingand

SS304Armourfor500HrsasperDIN50021Standard

5. MicroSwitchratingTest: a)ML-1005H:

3A@250VAC&3A@250VDC

b)ML-1005AH:15A@250VAC&0.5A@250VDC

type tested forModel 1005H/1005aHTypeofInstrument OTI/WTIRange R1.0-150°C

R2.0-160°CR3.30-150°CR4.-20to140°C(otherrangesonrequest)

No.ofSwitches S2-2switchesS3-3switchesS4-4switchesS5-5switches

SwitchConfigura-tion

L-NormallyopencontactL2-Changeovercontact

CapillaryLength C1-1mtsC2-2mts.......uptoC25-25mts

UnionType U1-1/2“BSPMaleU2-3/4”BSPMaleU3-1”BSPMaleU4-1/2”BSPFemaleU5-3/4”BSPFemale

CCUOutputforindication/Scada

RI-Remoteindicator-T1/T2/T3/T4(fortypes,ReferDrawing)PSU-Externalpowersupplywith2Nos.of4-20mAoutput

IfWTIpleasespecify

TransformerCTSecondaryoutput..................(1Ato5A)SimulatedTemperatureriseovertopoil...........(5°Cto30°C)

ordering information

Note:WTIGradientisfactoryset.Ifrequiredcustomercanadjustasperrequirment.

SampleOrderingInformation:1005AH\OTI\R4\S4\L\C6\U4\RI-T2...........Amps...............°C

Registered Office & Works :No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. INdIa

Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–[email protected]

Branch Office & Works :No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. INdIa

Phone : + 91-44-2250 0191 / 2250 0175Fax : + 91-44-2250 0175E-Mail : sales–[email protected]

PRecimeasuRe cOntROls Pvt. ltd.

Western india Region Office :Mobile : 09377561070E-Mail : [email protected]

Page 5: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

Precimeasure

PSU

MODEL - 1005HX / 1005AHXDIAL TYPE THERMOMETER

Remote Indicator 96 Sq

Duplex Hybrid OTI / WTI

SpecificationS Model : 1005HX Model : 1005aHXTemperatureRange 0-1500C,0-1600C,30-1500C,

-20to1400C0-1500C,0-1600C,30-1500C,-20to1400C

DialSize 150mm(6”)Round 150mm(6”)RoundDialangularSweep 2700 2700

DialGraduation 10C 10CAccuracyClass ±1%ofFSD ±1%ofFSDMax.No.ofSwitches 5 5SwitchingRange 15%-85% 15%-85%ContactRating 3A @ 250V AC/DC

Magnetic Blowout Micro switch15A @ 250V AC0.5A @ 250V DCStandard Micro switch

SwitchDifferential S1&S2:3°Cto9°C(6±30C)FixedS3toS5:8°Cto400CAdjustable.

S1&S2:3°Cto90C(6±30C)FixedS3toS5:80Cto400CAdjustable.

SwitchingAccuracy ±2.50CofSetValue ±2.50CofSetValueRemoteindicator Available/4-20mA/RS-485 Available/4-20mA/RS-485Max.CapillaryLength Upto25Mtrs. Upto25Mtrs.SwitchTestKnob Available AvailableElectricalConnection PressFitWagoType PressFitWagoTypeDegreeofProtection IP–55(IEC-60529) IP–55(IEC-60529)HighVoltageTest 2.5KVAC,50Hz/60Hzfor1

minute;Switchconnection&C.T.Terminaltoground.CCUoutput0.5KVAC50Hz/60Hzfor1minute

2.5KVAC,50Hz/60Hzfor1minute;Switchconnection&C.T.Terminaltoground.CCUoutput0.5KVAC50Hz/60Hzfor1minute

Electricalentry M20-3Nos M20-3Nos

CableGland Optional Optional

Thermometerpocket Optional Optional

ML: 1005 HX/1005 AHX

• Thefullysealedliquidexpansioninthesystemprovidesaselfpoweredindicationandoperationtotheinstruments,anddoesnotrequireanytrimmingorotherperiodicadjustments.

• Instrumentsarefullycompensatedforambienttemperature.• TheWTIinstrumentshaveabuiltinThermalimagingsystemfortransformer’shotspotindication.• TheWTIsareprovidedwithgradientadjustmentthroughashuntforCTsecondaryinput(1Ato5A).• embedded duplex pt-100 sensors in the sensing bulb of the local oti/ Wti provide for a

master indication.• CurrentConverterUnits(CCUs)aremountedinsidetheLocalOTI/WTI,Theoutputfromwhichcanbe

connectedtoremoteindicatorandSCADAthroughexternalpowersupplyunits(PSUs).• FortheWTIsadditionalWindingtemperaturesimulatorisprovided• Instrument cases are aluminium die casted and polyester powder coated. Each instrument hasantivibrationmountingsandareprovidedwithprojectionmountingclamps.

• Amaximumpointerfacilityisprovided,canberesetfromoutside.• Allswitchcontactsarepotentialfreemicroswitches

General features

poWer Supply unit - (pSu)

a. OutputVoltage:24V

b. OutputSignal:Analogueoutput2nos.4-20mADC(Output-1,Burden250Ohms)(Output-2,Burden600Ohms)

c. Auxiliarysupply:90-260VAC/DC

reMote indicator

a Type:4digits,0.5’’SevenSegmentLED’sb AuxiliarySupply:90–260VAC/DCd Resolution:0.10Ce Degreeofprotectionofenclosure:IP-20f OperatingTemperatureRange:0°Cto60°Cg Signaloutput:4setsof4-20mADC,Optional

RS485h CutoutDimension:92Sq.mm

DIA

L TY

PE

Page 6: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

1. Protectionclass: IP55asperIEC60529CAT2.

2. ColdandDryTest: -40°Cto+70°C

3. VibrationTest: Amplitude1mm,frequency50Hz,

1Hr/X,Y,Zaxis

4. SaltSprayTest: Forpolysterpowdercoatingand

SS304Armourfor500HrsasperDIN50021Standard

5. MicroSwitchratingTest: a)ML-1005HX:

3A@250VAC&3A@250VDC

b)ML-1005AHX:15A@250VAC&0.5A@250VDC

type tested forModel 1005HX/1005aHXTypeofInstrument OTI/WTIRange R1.0-150°C

R2.0-160°CR3.30-150°CR4.-20to140°C(otherrangesonrequest)

No.ofSwitches S2-2switchesS3-3switchesS4-4switchesS5-5switches

SwitchConfiguration L-NormallyopencontactL2-Changeovercontact

CapillaryLength C1-1mtsC2-2mts.......uptoC25-25mts

UnionType U1-1/2“BSPMaleU2-3/4”BSPMaleU3-1”BSPMaleU4-1/2”BSPFemaleU5-3/4”BSPFemale

CCUOutputforindication/Scada

RI-Remoteindicator-T1/T2/T3/T4(ForTypes,ReferDrawing)(ConnectedthroughexternalpowersupplyPSUs)

IfWTIpleasespecify TransformerCTSecondaryoutput..................(1Ato5A)SimulatedTemperatureriseovertopoil...........(5°Cto30°C)

ordering information

Note:WTIGradientisfactoryset.Ifrequiredcustomercanadjustasperrequirment.

SampleOrderingInformation:1005AHX\OTI\R4\S4\L\C6\U4\RI-T1...........Amps.............°C

Registered Office & Works :No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. INdIa

Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–[email protected]

Branch Office & Works :No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. INdIa

Phone : + 91-44-2250 0191 / 2250 0175Fax : + 91-44-2250 0175E-Mail : sales–[email protected]

PRecimeasuRe cOntROls Pvt. ltd.

Western india Region Office :Mobile : 09377561070E-Mail : [email protected]

Page 7: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

Precimeasure

• Thefullysealedliquidexpansioninthesystemprovidesaselfpoweredindicationandoperationtotheinstruments,anddoesnotrequireanytrimmingorotherperiodicadjustments.

• Instrumentsarefullycompensatedforambienttemperature.• TheWTIinstrumentshaveabuiltinThermalimagingsystemfortransformer’shotspotindication.• TheWTIsareprovidedwithgradientadjustmentthroughashuntforCTsecondaryinput(1Ato5A).• Instrument cases are aluminium die casted and polyester powder coated. Each instrument hasantivibrationmountingsandareprovidedwithprojectionmountingclamps.

• Amaximumpointerfacilityisprovided,canberesetfromoutside.• Allswitchcontactsarepotentialfreemicroswitches

MODEL - 1007DIAL TYPE THERMOMETER

Remote Repeater 96 Sq

General features

Standard OTI / WTI

ML : 1007

PSU

SpecificationS Model : 1007TemperatureRange 0-1500C,0-1600C,30-1500C,-20to1400CDialSize 115mm,SegmentDialDialangularSweep 600

DialGraduation 20CAccuracyClass ±1.5%ofFSDMax.No.ofSwitches 4SwitchingRange 15%-85%ContactRating 15A@250VAC

0.5A@250VDCStandardMicroswitch

SwitchDifferential S1&S2:3°Cto9°C(6±30C)FixedS3&S4:8°Cto400CAdjustable.

SwitchingAccuracy ±2.50CofSetValueRemoteRepeater Available(PotentiometerOutput)Max.CapillaryLength Upto25Mtrs.ElectricalConnection PressFitWagoTypeDegreeofProtection IP–55(IEC-60529)HighVoltageTest 2.5KVAC,50Hz/60Hzfor1minute;allTerminals

toground

Electricalentry M20-3Nos

CableGland Optional

ThermometerPocket Optional

DIA

L TY

PE

poWer Supply unit - (pSu)

a. OutputVoltage:24V

b. OutputSignal:Analogueoutput2nos.4-20mADC(Output-1,Burden250Ohms)(Output-2,Burden600Ohms)

c. Auxiliarysupply:90-260VAC/DC

reMote indicator

a Type:4digits,0.5’’SevenSegmentLED’sb AuxiliarySupply:90–260VAC/DCd Resolution:0.10Ce Degreeofprotectionofenclosure:IP-20f OperatingTemperatureRange:0°Cto60°Cg Signaloutput:4setsof4-20mADC,Optional

RS485h CutoutDimension:92Sq.mm

Page 8: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

1. Protectionclass: IP55asperIEC60529CAT2.

2. ColdandDryTest: -40°Cto+70°C

3. VibrationTest: Amplitude1mm,frequency50Hz,

1Hr/X,Y,Zaxis

4. SaltSprayTest: Forpolysterpowdercoatingand

SS304Armourfor500HrsasperDIN50021Standard

5. MicroSwitchratingTest: 15A@250VAC&

0.5A@250VDC

type tested for

Model 1007TypeofInstrument OTI/WTIRange R1.0-150°C

R2.0-160°CR3.30-150°CR4.-20to140°C(otherrangesonrequest)

No.ofSwitches S2-2switchesS3-3switchesS4-4switches

SwitchConfiguration L-NormallyopencontactL2-Changeovercontact

CapillaryLength C1-1mtsC2-2mts.......uptoC25-25mts

UnionType U1-1/2“BSPMaleU2-3/4”BSPMaleU3-1”BSPMaleU4-1/2”BSPFemaleU5-3/4”BSPFemale

Repeater Y-Requried,N-NotRequired

IfWTIpleasespecify TransformerCTSecondaryoutput..................(1Ato5A)SimulatedTemperatureriseovertopoil...........(5°Cto30°C)

ordering information

Note:WTIGradientisfactoryset.Ifrequiredcustomercanadjustasperrequirment.

SampleOrderingInformation:1007\OTI\R3\S2\L2\C8\U5\Y\...........Amps...............°C

Registered Office & Works :No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. INdIa

Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–[email protected]

Branch Office & Works :No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. INdIa

Phone : + 91-44-2250 0191 / 2250 0175Fax : + 91-44-2250 0175E-Mail : sales–[email protected]

PRecimeasuRe cOntROls Pvt. ltd.

Western india Region Office :Mobile : 09377561070E-Mail : [email protected]

Page 9: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

Precimeasure

• Thefullysealedliquidexpansioninthesystemprovidesaselfpoweredindicationandoperationtotheinstruments,anddoesnotrequireanytrimmingorotherperiodicadjustments.

• Instrumentsarefullycompensatedforambienttemperature.

• TheWTIinstrumentshaveabuiltinThermalimagingsystemfortransformer’shotspotindication.

• TheWTIsareprovidedwithgradientadjustmentthroughashuntforCTsecondaryinput(1Ato5A).

• Embedded PT-100 sensorsin the sensing bulb of the local OTI/ WTI provide for a master indication.

• CurrentConverterUnit(CCU)ismountedinsidetheLocalOTI/WTI,TheoutputfromwhichcanbeconnectedtoremoteindicatororSCADAareacombinationofboth.

• FortheWTIsadditionalWindingtemperaturesimulatorisprovided

• Instrumentcasesarealuminiumdiecastedandpolyesterpowdercoated.Eachinstrumenthasantivibrationmountingsandareprovidedwithprojectionmountingclamps.

• Amaximumpointerfacilityisprovided,canberesetfromoutside.

• Allswitchcontactsarepotentialfreemicroswitches

MODEL - 1007HDIAL TYPE THERMOMETER

General features

Hybrid OTI / WTI

ML : 1007H Specifications Model : 1007HTemperatureRange 0-1500C,0-1600C,30-1500C,-20to1400CDialSize 115mm,SegmentDialDialangularSweep 600

DialGraduation 20CAccuracyClass ±1.5%ofFSDMax.No.ofSwitches 4SwitchingRange 15%-85%ContactRating 15A@250VAC

0.5A@250VDCStandardMicroswitch

SwitchDifferential S1&S2:3°Cto9°C(6±30C)FixedS3&S4:8°Cto400CAdjustable.

SwitchingAccuracy ±2.50CofSetValueRemoteIndicator Available/4-20mA/RS-485Max.CapillaryLength Upto25MtrsElectricalConnection PressFitWagoTypeDegreeofProtection IP–55(IEC-60529)HighVoltageTest 2.5KVAC,50Hz/60Hzfor1minute;Switch

connection&C.T.Terminaltoground.CCUoutput0.5KvAc50Hz/60Hzfor1minute

Electricalentry M20-3Nos

CableGland Optional

ThermometerPacket Optional

DIA

L TY

PE

poWer Supply unit - (pSu)

a. OutputVoltage:24V

b. OutputSignal:Analogueoutput2nos.4-20mADC(Output-1,Burden250Ohms)(Output-2,Burden600Ohms)

c. Auxiliarysupply:90-260VAC/DC

reMote indicator

a Type:4digits,0.5’’SevenSegmentLED’sb AuxiliarySupply:90–260VAC/DCd Resolution:0.10Ce Degreeofprotectionofenclosure:IP-20f OperatingTemperatureRange:0°Cto60°Cg Signaloutput:4setsof4-20mADC,Optional

RS485h CutoutDimension:92Sq.mm

Remote Repeater 96 Sq

PSU

Page 10: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

1. Protectionclass: IP55asperIEC60529CAT2.

2. ColdandDryTest: -40°Cto+70°C

3. VibrationTest: Amplitude1mm,frequency50Hz,

1Hr/X,Y,Zaxis

4. SaltSprayTest: Forpolysterpowdercoatingand

SS304Armourfor500HrsasperDIN50021Standard

5. MicroSwitchratingTest: 15A@250VAC& 0.5A@250VDC

type tested for

Model 1007HTypeofInstrument OTI/WTIRange R1.0-150°C

R2.0-160°CR3.30-150°CR4.-20to140°C(otherrangesonrequest)

No.ofSwitches S2-2switchesS3-3switchesS4-4switches

SwitchConfiguration L-NormallyopencontactL2-Changeovercontact

CapillaryLength C1-1mtsC2-2mts.......uptoC25-25mts

UnionType U1-1/2“BSPMaleU2-3/4”BSPMaleU3-1”BSPMaleU4-1/2”BSPFemaleU5-3/4”BSPFemale

CCUOutputforindication/Scada

RI-Remoteindicator-T1/T2/T3/T4(Fortypes,referDrawing)PSU-Externalpowersupplywith2Nos.of4-20mAoutput

IfWTIpleasespecify TransformerCTSecondaryoutput..................(1Ato5A)SimulatedTemperatureriseovertopoil...........(5°Cto30°C)

ordering information

Note:WTIGradientisfactoryset.Ifrequiredcustomercanadjustasperrequirment.

SampleOrderingInformation:1007H\OTI\R3\S2\L2\C8\U5\RI-T4...........Amps...............°C

Registered Office & Works :No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. INdIa

Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–[email protected]

Branch Office & Works :No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. INdIa

Phone : + 91-44-2250 0191 / 2250 0175Fax : + 91-44-2250 0175E-Mail : sales–[email protected]

PRecimeasuRe cOntROls Pvt. ltd.

Western india Region Office :Mobile : 09377561070E-Mail : [email protected]

Page 11: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

Precimeasure

• Thefullysealedliquidexpansioninthesystemprovidesaselfpoweredindicationandoperationtotheinstruments,anddoesnotrequireanytrimmingorotherperiodicadjustments.

• Instrumentsarefullycompensatedforambienttemperature.• TheWTIinstrumentshaveabuiltinThermalimagingsystemfortransformer’shotspotindication.• TheWTIsareprovidedwithgradientadjustmentthroughashuntforCTsecondaryinput(1Ato5A).• Instrument cases are aluminium die casted and polyester powder coated. Each instrument hasantivibrationmountingsandareprovidedwithprojectionmountingclamps.

• Amaximumpointerfacilityisprovided,canberesetfromoutside.• Allswitchcontactsarepotentialfreemicroswitches.

MODEL - 1006DIAL TYPE THERMOMETER

General features

Standard OTI / WTI

ML : 1006

SpecificationS Model : 1006

TemperatureRange 0-1500C,0-2400C

DialangularSweep 2700

DialGraduation 20C

AccuracyClass ±1.5%ofFSD

Max.No.ofSwitches 2

SwitchingRange 15%-85%

ContactRating5A@250VAC,

0.5A@220VDC

SwitchDifferential 10Cto50C(30C±20C)Fixed

SwitchingAccuracy ±2.50CofSetValue

Max.CapillaryLength Upto6Mtrs.

SwitchTestKnob Available

ElectricalConnection 1Sqmm.CopperCable,1mtrLength

DegreeofProtection IP–55(IEC-60529)

HighVoltageTest2.5KVAC,50Hz/60Hzfor1minute;allTerminaltoground

DIA

L TY

PE

Page 12: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

Model 1006TypeofInstrument OTI/WTIRange R1.0-150°C.

R2.0-240°CNo.ofSwitches S2-2switchesSwitchConfiguration L-Normallyopencontact

L2-ChangeovercontactCapillaryLength C1-1mts

C2-2mts.......uptoC6-6mtsUnionType U1-1/2“BSPMale

U2-3/4”BSPMaleU3-1”BSPMaleU4-1/2”BSPFemaleU5-3/4”BSPFemale

IfWTIpleasespecify TransformerCTSecondaryoutput..................(1Ato5A)SimulatedTemperatureriseovertopoil...........(5°Cto30°C)

ordering information

Note:WTIGradientisfactoryset.Ifrequiredcustomercanadjustasperrequirment.

SampleOrderingInformation:1006\WTI\R1\S2\L2\C5\U5...........Amps...............°C

1.Protectionclass: IP55asperIEC60529CAT2.

2.VibrationTest: Amplitude1mm, frequency50Hz,1Hr/X,Y,Zaxis

3.SaltSprayTest: Forpolysterpowdercoating andSS304Armourfor500Hrs asperDIN50021Standard

4.MicroSwitchratingTest: 5A@250VAC, 0.5A@220VDC

type tested for

Registered Office & Works :No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. INdIa

Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–[email protected]

Branch Office & Works :No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. INdIa

Phone : + 91-44-2250 0191 / 2250 0175Fax : + 91-44-2250 0175E-Mail : sales–[email protected]

PRecimeasuRe cOntROls Pvt. ltd.

Western india Region Office :Mobile : 09377561070E-Mail : [email protected]

Page 13: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

Precimeasure

• Thefullysealedliquidexpansioninthesystemprovidesaselfpoweredindicationandoperationtotheinstruments,anddoesnotrequireanytrimmingorotherperiodicadjustments.

• Instrumentsarefullycompensatedforambienttemperature.• TheWTIinstrumentshaveabuiltinThermalimagingsystemfortransformer’shotspotindication.• TheWTIsareprovidedwithgradientadjustmentthroughashuntforCTsecondaryinput(1Ato5A).• Embedded PT-100 sensorsin the sensing bulb of the local OTI/ WTI provide for a master indication.

• Instrument cases are aluminium die casted and polyester powder coated. Each instrument hasantivibrationmountingsandareprovidedwithprojectionmountingclamps.

• Amaximumpointerfacilityisprovided,canberesetfromoutside.• Allswitchcontactsarepotentialfreemicroswitches.

MODEL - 1006HDIAL TYPE THERMOMETER

General features

Hybrid OTI / WTI

ML : 1006H SpecificationS Model : 1006H

TemperatureRange 0-1500C,0-2400C

DialangularSweep 2700

DialGraduation 20C

AccuracyClass ±1.5%ofFSD

Max.No.ofSwitches 2

SwitchingRange 15%-85%

ContactRating5A@250VAC,

0.5A@220VDC

SwitchDifferential 10Cto50C(30C±20C)Fixed

SwitchingAccuracy ±2.50CofSetValue

RemoteIndicator Availbale

Max.CapillaryLength Upto6Mtrs.

SwitchTestKnob Available

ElectricalConnection 1Sqmm.CopperCable,1mtrLength

DegreeofProtection IP–55(IEC-60529)High Voltage test

(a)LocalOTI/WTI

(b)LocalOTI/WTI

(c)CCU

(d)CCU

test Voltage

2.5KVAC,50Hz/60Hz

500VAC,50Hz/60Hz

500VAC,50Hz/60Hz

2.5KVAC,50Hz/60Hz

terminals details

Switchconnection/CTConnection

Pt100sensoroutput

Pt100sensorinput+4-20mAOutput

CTconnectionwithpowersupply

ML : 2220-R2 (CCU)

Remote Indicator 96 Sq

Specification

Type 4digits,0.5’’SevenSegmentsLED’s

AuxillarySupply 90–260VAC/DC

Resolution 0.10C

Degreeofprotectionofenclosure IP20

OperatingTemperatureRange 00Cto600C

Signaloutput 4setsof4-20mADC,OptionalRS485

Cutoutdimension 92Sq.mm

DIA

L TY

PE

Page 14: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

1. Protectionclass: IP55asperIEC60529CAT2.

2. VibrationTest: Amplitude1mm,frequency50Hz,

1Hr/X,Y,Zaxis

3. SaltSprayTest: Forpolysterpowdercoatingand

SS304Armourfor500HrsasperDIN50021Standard

4. MicroSwitchratingTest: 5A@250VAC,

0.5A@220VDC

type tested forModel 1006HTypeofInstrument OTI/WTIRange R1.0-150°C.

R2.0-240°CNo.ofSwitches S2-2switchesSwitchConfiguration L-Normallyopencontact

L2-ChangeovercontactCapillaryLength C1-1mts

C2-2mts.......uptoC6-6mtsUnionType U1-1/2“BSPMale

U2-3/4”BSPMaleU3-1”BSPMaleU4-1/2”BSPFemaleU5-3/4”BSPFemale

IfWTIpleasespecify TransformerCTSecondaryoutput..................(1Ato5A)SimulatedTemperatureriseovertopoil...........(5°Cto30°C)

ordering information

Note:1)WTIGradientisfactoryset.Ifrequiredcustomercanadjustasperrequirment. 2)ExternalCCUandRemoteIndicatorisPartofthescheme.

SampleOrderingInformation:1006H\WTI\R1\S2\L\C3\U2...........Amps...............°C

Registered Office & Works :No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. INdIa

Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–[email protected]

Branch Office & Works :No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. INdIa

Phone : + 91-44-2250 0191 / 2250 0175Fax : + 91-44-2250 0175E-Mail : sales–[email protected]

PRecimeasuRe cOntROls Pvt. ltd.

Western india Region Office :Mobile : 09377561070E-Mail : [email protected]

Page 15: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

Precimeasure MODEL - 1006DHDIAL TYPE THERMOMETER for

DRY TYPE TRANSFORMER

General features

ML : 1006DHSpecifications Model : 1006dH

TemperatureRange 0-2400C

DialangularSweep 2700

DialGraduation 20C

AccuracyClass ±1.5%ofFSD

Max.No.ofSwitches 2

SwitchingRange 15%-85%

ContactRating5A@250VAC,

0.5A@220VDC

SwitchDifferential 10Cto50C(30C±20C)Fixed

SwitchingAccuracy ±40CofSetValue

RemoteIndicator Availbale

Max.CapillaryLength Upto6mtrs

ElectricalConnection 1Sqmm.CopperCable,1mtrLength

DegreeofProtection IP–55(IEC-60529)

HighVoltageTest

SwitchContact-2.5KVAC,50Hz/60Hzfor1MinutebetweenSwitchTerminalstoground

CCU-500VAC,50Hz/60Hzfor1MinutebetweenCCUTerminalstoground

PSU

Hybrid InstrumentThisisahighperformancetemperatureMonitoringinstrumentwithbuilt-inPT-100Sensor(RTD)&CurrentConverterUnitandexternalRemoteindicatorwithbuilt-inpowersupplyunit

WindingtemperaturesIndicator&ControllerforDryTypeTransformers/Cast-ResinTransformerswithbuilt-inRTDschemeforIndependentRemoteindicationand4-20mADCoutputforSCADAconnection.

power Supply unit

Signaloutput 2nos4-20mADC

AuxSupplyvoltage 90-260VAC/DC

Burdenonsignaloutput 600Ωmaxincludingloopresistance

Temperaturerange 0-240°C

Degreeofprotection IP-40

Temperaturerange 0-240°C

Signalinput 4-20mADC

AuxSupplyvoltage 90-260VAC/DC

Communication RS-485MODBUSRTUCommunication(Optional)

Degreeofprotection IP20

CutoutDimension 92sq.mm

digital remote indicator

Remote Indicator 96 Sq

• Thefullysealedliquidexpansioninthesystemprovidesaselfpoweredindicationandoperationtotheinstruments,anddoesnotrequireanytrimmingorotherperiodicadjustments.

• Instrumentsarefullycompensatedforambienttemperature.• Instrument cases are aluminium die casted and polyester powder coated. Each instrument hasantivibrationmountingsandareprovidedwithprojectionmountingclamps.

• Amaximumpointerfacilityisprovided,canberesetfromoutside.• Allswitchcontactsarepotentialfreemicroswitches

DIA

L TY

PE

Page 16: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

1. Protectionclass: IP55asperIEC60529CAT2.

2. VibrationTest: Amplitude1mm,frequency50Hz,

1Hr/X,Y,Zaxis

3. SaltSprayTest: Forpolysterpowdercoatingand

SS304Armourfor500HrsasperDIN50021Standard

4. MicroSwitchratingTest: 5A@250VAC,

0.5A@220VDC

type tested forModel 1006DHTypeofInstrument WTIRange R1.0-240°CNo.ofSwitches S2-2switchesSwitchConfiguration L-Normallyopencontact

L2-ChangeovercontactCapillaryLength C1-1mts

C2-2mts.......uptoC6-6mts

ordering information

Note:WTIGradientisfactoryset.Ifrequiredcustomercanadjustasperrequirment.

SampleOrderingInformation:1006DH\WTI\R1\S2\L\C4

Registered Office & Works :No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. INdIa

Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–[email protected]

Branch Office & Works :No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. INdIa

Phone : + 91-44-2250 0191 / 2250 0175Fax : + 91-44-2250 0175E-Mail : sales–[email protected]

PRecimeasuRe cOntROls Pvt. ltd.

Western india Region Office :Mobile : 09377561070E-Mail : [email protected]

Page 17: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

Precimeasure MODEL - 1006HXDIAL TYPE THERMOMETER

Duplex Hybrid OTI / WTI

ML : 1006HX

SpecificationS Model : 1006HXTemperatureRange 0-1500C,0-2400C

DialangularSweep 2700

DialGraduation 20C

AccuracyClass ±1.5%ofFSD

Max.No.ofSwitches 2

SwitchingRange 15%-85%

ContactRating5A@250VAC,

0.5A@220VDC

SwitchDifferential 10Cto50C(30C±20C)Fixed

SwitchingAccuracy ±2.50CofSetValue

RemoteIndicator Availbale

Max.CapillaryLength Upto6Mtrs.

SwitchTestKnob Available

ElectricalConnection 1Sqmm.CopperCable,1mtrlength

DegreeofProtection IP–55(IEC-60529)

High Voltage test

(a)LocalOTI/WTI

(b)LocalOTI/WTI

(c)CCU

(d)CCU

test Voltage

2.5KVAC,50Hz/60Hz

500VAC,50Hz/60Hz

500VAC,50Hz/60Hz

2.5KVAC,50Hz/60Hz

terminals details

Switchconnection/CTConnection

Pt100sensoroutput

Pt100sensorinput+4-20mAOutput

CTconnectionwithpowersupply

• Thefullysealedliquidexpansioninthesystemprovidesaselfpoweredindicationandoperationtotheinstruments,anddoesnotrequireanytrimmingorotherperiodicadjustments.

• Instrumentsarefullycompensatedforambienttemperature.• TheWTIinstrumentshaveabuiltinThermalimagingsystemfortransformer’shotspotindication.• TheWTIsareprovidedwithgradientadjustmentthroughashuntforCTsecondaryinput(1Ato5A).• Embedded Duplex PT-100 sensorsin the sensing bulb of the local OTI/ WTI provide for a

master indication.• ThisoutputcanbeconnectedtoRemoteIndicatororSCADAorcombinationofboth.• WTIadditionalWindingtemperaturesimulatorisprovided.• Instrument cases are aluminium die casted and polyester powder coated. Each instrument hasantivibrationmountingsandareprovidedwithprojectionmountingclamps.

• Amaximumpointerfacilityisprovided,canberesetfromoutside.• Allswitchcontactsarepotentialfreemicroswitches.

General features

PSU

Remote Indicator 96 Sq

poWer Supply unit - (pSu)

a. OutputVoltage:24V

b. OutputSignal:Analogueoutput2nos.4-20mADC(Maximumburden600OhmsIncludingLoopresistantance)

c. Auxiliarysupply:90-260VAC/DC

reMote indicator

a Type:4digits,0.5’’SevenSegmentLED’sb AuxiliarySupply:90–260VAC/DCd Resolution:0.10Ce Degreeofprotectionofenclosure:IP-20f OperatingTemperatureRange:0°Cto60°Cg Signaloutput:4setsof4-20mADC,Optional

RS485h CutoutDimension:92Sq.mm

DIA

L TY

PE

Page 18: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

1. Protectionclass: IP55asperIEC60529CAT2.

2. VibrationTest: Amplitude1mm,frequency50Hz,

1Hr/X,Y,Zaxis

3. SaltSprayTest: Forpolysterpowdercoatingand

SS304Armourfor500HrsasperDIN50021Standard

4. MicroSwitchratingTest: a)ML-1006HX:

5A@250VAC,

0.5A@220VDC

type tested forModel 1006HXTypeofInstrument OTI/WTIRange R1.0-150°C.

R2.0-240°CNo.ofSwitches S2-2switchesSwitchConfiguration L-Normallyopencontact

L2-ChangeovercontactCapillaryLength C1-1mts

C2-2mts.......uptoC6-6mtsUnionType U1-1/2“BSPMale

U2-3/4”BSPMaleU3-1”BSPMaleU4-1/2”BSPFemaleU5-3/4”BSPFemale

CCUOutputforindication/Scada

RI-Remoteindicator-T1/T2/T3/T4(Fortypes,ReferDrawing(ConnectedthroughexternalpowersupplyPSUs)

IfWTIpleasespecify TransformerCTSecondaryoutput..................(1Ato5A)SimulatedTemperatureriseovertopoil...........(5°Cto30°C)

ordering information

Note:WTIGradientisfactoryset.Ifrequiredcustomercanadjustasperrequirment.

SampleOrderingInformation:1006HX\OTI\R2\S2\L\C4\U1\RI-T3...........Amps...............°C

Registered Office & Works :No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. INdIa

Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–[email protected]

Branch Office & Works :No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. INdIa

Phone : + 91-44-2250 0191 / 2250 0175Fax : + 91-44-2250 0175E-Mail : sales–[email protected]

PRecimeasuRe cOntROls Pvt. ltd.

Western india Region Office :Mobile : 09377561070E-Mail : [email protected]

Page 19: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

Precimeasure

• Thefullysealedliquidexpansioninthesystemprovidesaselfpoweredindicationandoperationtotheinstruments,anddoesnotrequireanytrimmingorotherperiodicadjustments.

• Instrumentsarefullycompensatedforambienttemperature.• TheWTIinstrumentshaveabuiltinThermalimagingsystemfortransformer’shotspotindication.• TheWTIsareprovidedwithgradientadjustmentthroughashuntforCTsecondaryinput(1Ato5A).• Instrumentcasesarealuminiumdiecastedandpolyesterpowdercoated.Each instrumenthasantivibrationmountingsandareprovidedwithprojectionmountingclamps.

• Amaximumpointerfacilityisprovided,canberesetfromoutside.• Allswitchcontactsarepotentialfreemicroswitches.

MODEL - 1031DIAL TYPE THERMOMETER

General features

Standard OTI / WTI

ML : 1031

SpecificationS Model : 1031

TemperatureRange 0-1500C

Dialsize 115mm,SegmentDial

DialangularSweep 600

DialGraduation 20C

AccuracyClass ±1.5%ofFSD

Max.No.ofSwitches 2

SwitchingRange 15%-85%

ContactRating5A@250VAC

0.5A@220VDC

SwitchDifferential 10Cto50C(30C±20C)Fixed

SwitchingAccuracy ±2.50CofSetValue

Max.CapillaryLength Upto6Mtrs.

ElectricalConnection 1Sqmm.CopperCable,1mtrLength

DegreeofProtection IP–55(IEC-60529)

HighVoltageTest 2.5KVAC,50Hz/60Hzfor1minute;Allterminaltoground

DIA

L TY

PE

Page 20: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

Model 1031TypeofInstrument OTI/WTIRange R1.0-150°C.No.ofSwitches S2-2switchesSwitchConfiguration L-Normallyopencontact

L2-ChangeovercontactCapillaryLength C1-1mts

C2-2mts.......uptoC6-6mtsUnionType U1-1/2“BSPMale

U2-3/4”BSPMaleU3-1”BSPMaleU4-1/2”BSPFemaleU5-3/4”BSPFemale

IfWTIpleasespecify TransformerCTSecondaryoutput..................(1Ato5A)SimulatedTemperatureriseovertopoil...........(5°Cto30°C)

ordering information

Note:WTIGradientisfactoryset.Ifrequiredcustomercanadjustasperrequirment.

SampleOrderingInformation:1031\OTI\R1\S2\L2\C6\U2...........Amps...............°C

1. Protectionclass: IP55asperIEC60529CAT2.

2. VibrationTest: Amplitude1mm,frequency50Hz,

1Hr/X,Y,Zaxis

3. SaltSprayTest: Forpolysterpowdercoatingand

SS304Armourfor500HrsasperDIN50021Standard

4. MicroSwitchratingTest: 5A@250VAC,

0.5A@220VDC

type tested for

Registered Office & Works :No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. INdIa

Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–[email protected]

Branch Office & Works :No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. INdIa

Phone : + 91-44-2250 0191 / 2250 0175Fax : + 91-44-2250 0175E-Mail : sales–[email protected]

PRecimeasuRe cOntROls Pvt. ltd.

Western india Region Office :Mobile : 09377561070E-Mail : [email protected]

Page 21: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

Precimeasure

• Thefullysealedliquidexpansioninthesystemprovidesaselfpoweredindicationandoperationtotheinstruments,anddoesnotrequireanytrimmingorotherperiodicadjustments.

• Instrumentsarefullycompensatedforambienttemperature.• TheWTIinstrumentshaveabuiltinThermalimagingsystemfortransformer’shotspotindication.• TheWTIsareprovidedwithgradientadjustmentthroughashuntforCTsecondaryinput(1Ato5A).• Embedded PT-100 sensorsin the sensing bulb of the local OTI/ WTI provide for a master indication.

• Instrument cases are aluminium die casted and polyester powder coated. Each instrument hasantivibrationmountingsandareprovidedwithprojectionmountingclamps.

• Amaximumpointerfacilityisprovided,canberesetfromoutside.• Allswitchcontactsarepotentialfreemicroswitches.

MODEL - 1031HDIAL TYPE THERMOMETER

General features

Hybrid OTI / WTI

ML : 1031H SpecificationS Model : 1031H

TemperatureRange 0-1500C

DialSize 115mm,SegmentDial

DialangularSweep 600

DialGraduation 20C

AccuracyClass ±1.5%ofFSD

Max.No.ofSwitches 2

SwitchingRange 15%-85%

ContactRating5A@250VAC,

0.5A@220VDC

SwitchDifferential 10Cto50C(30C±20C)Fixed

SwitchingAccuracy ±2.50CofSetValue

RemoteIndicator Availbale

Max.CapillaryLength Upto6Mtrs.

ElectricalConnection 1Sqmm.CopperCable,1mtrLenght

DegreeofProtection IP–55(IEC-60529) ML : 2220-R2 (CCU)

Remote Indicator

SpecificationS

Type 4digits,0.5’’SevenSegmentsLED’s

AuxillarySupply 90–260VAC/DC

Resolution 0.10C

Degreeofprotectionofenclosure IP20

OperatingTemperatureRange 00Cto600C

Signaloutput 4setsof4-20mADC,OptionalRS485

Cutoutdimension 92Sq.mm

High Voltage test

(a)LocalOTI/WTI

(b)LocalOTI/WTI

(c)CCU

(d)CCU

test Voltage

2.5KVAC,50Hz/60Hz

500VAC,50Hz/60Hz

500VAC,50Hz/60Hz

2.5KVAC,50Hz/60Hz

terminals details

Switchconnection/CTConnection

Pt100sensoroutput

Pt100sensorinput+4-20mAOutput

CTconnectionwithpowersupply

DIA

L TY

PE

Page 22: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

Model 1031HTypeofInstrument OTI/WTIRange R1.0-150°C.No.ofSwitches S2-2switchesSwitchConfiguration L-Normallyopencontact

L2-ChangeovercontactCapillaryLength C1-1mts

C2-2mts.......uptoC6-6mtsUnionType U1-1/2“BSPMale

U2-3/4”BSPMaleU3-1”BSPMaleU4-1/2”BSPFemaleU5-3/4”BSPFemale

IfWTIpleasespecify TransformerCTSecondaryoutput..................(1Ato5A)SimulatedTemperatureriseovertopoil...........(5°Cto30°C)

ordering information

SampleOrderingInformation:1031H\WTI\R1\S2\L\C3\U2...........Amps...............°C

1. Protectionclass: IP55asperIEC60529CAT2.

2. VibrationTest: Amplitude1mm,frequency50Hz,

1Hr/X,Y,Zaxis

3. SaltSprayTest: Forpolysterpowdercoatingand

SS304Armourfor500HrsasperDIN50021Standard

4. MicroSwitchratingTest: 5A@250VAC,

0.5A@220VDC

type tested for

Note:1)WTIGradientisfactoryset.Ifrequiredcustomercanadjustasperrequirment. 2)ExternalCCUandRemoteIndicatorisPartofthescheme.

Registered Office & Works :No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. INdIa

Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–[email protected]

Branch Office & Works :No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. INdIa

Phone : + 91-44-2250 0191 / 2250 0175Fax : + 91-44-2250 0175E-Mail : sales–[email protected]

PRecimeasuRe cOntROls Pvt. ltd.

Western india Region Office :Mobile : 09377561070E-Mail : [email protected]

Page 23: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

Precimeasure DIAL TYPE BI - METALLIC THERMOMETER

Bi-metallic type thermometer consists of Helical Bimetal coil, which will expand or contract according to the temperature changes, which in turn operates indicating pointer.

General featuresa Noexternalpowersupplyrequiredforindicationoroperation.a Sealedsystemwhichrequiresnotrimmingorperiodicsiteadjustmentsa DirectlymountedontheTransformer&OtherProcessControlEquipments.a Amaximumpointerfacilityisprovided,canberesetfromoutside.a Theinstrumentsarecapableofworkingatanambienttemperaturerangeof00Cto+600C.

Model 1070 (tHerMoMeter WitHout contact, top MountinG)

SpecificationSDial SegmentDialAngularSweep 1050

Range 0-1200C(Otherrangesonrequest)Accuracy ±40CBetween400C&1100CGraduation 20CperdivisionInstrumentCase PDCAluminumCastingwithPolyesterPowderCoated.

ML :1070

ML :1071

Model 1071 (tHerMoMeter WitH 2 contact, top MountinG)

SpecificationSDial SegmentDialAngularSweep 1050

Range 0-1200C(Otherrangesonrequest)Accuracy ±40CBetween400C&1100CGraduation 20CperdivisionInstrumentCase PDCAluminumCastingwithPolyesterPowderCoated.

Max.NumberofSwitches 2SwitchType MicroSwitchSwitchRating 5Aat240VACSwitches NormallyOpenTypeorChangeoverTypeAdjustableRange 200C–1050CAccuracyofswitchsetting ±40CofSetValueSwitchDifferentialRange 60C±30CContactType PotentialFreeCableGland(Polyamide/Brass) CableGlandSizePG16HighVoltageTest 2KVAC,50/60Hzfor1Minute,Allterminalstoground

BI-M

ETA

LLIC

Page 24: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

Model 1068 (4" dial tHerMoMeter WitH 2 contact, Horizontal MountinG)

SpecificationSDial RoundDial4’’AngularSweep 1350

Range 0-1200C(Otherrangesonrequest)Accuracy ±40CBetween400C&1100CGraduation 20CperdivisionInstrumentCase PDCAluminumCastingwithPolyesterPowderCoated

*TheWTIinstrumentshaveabuiltinThermalimagingsystemfortransformer’shotspotindication.

*WTIGradientcalibrationisfactorysetaspercustomerspecification.Ifrequired,aprovisionismadeforsmalladjustmentatsite.

Model 1071 – Wti (tHerMoMeter WitH 2 contact, top MountinG) WindinG teMperature indicator :

SpecificationS

Dial SegmentDialAngularSweep 1050

Range 0-1200C(Otherrangesonrequest)Accuracy ±40CBetween400C&1100CGraduation 20CperdivisionInstrumentCase PDCAluminumCastingwithPolyesterPowderCoated

Max.NumberofSwitches 2SwitchType MicroSwitchSwitchRating 5Aat240VACSwitches NormallyOpenTypeorChangeoverTypeAdjustableRange 200C–1050CSwitchingAccuracy ±40CofSetValueSwitchDifferential 60C±30CContactType PotentialFreeCableGland(Polyamide/Brass) CableGlandSizePG11-2NosHighVoltageTest 2KVAC,50Hzfor1Minute,Allterminalstoground

ML :1071-WTI

Registered Office & Works :No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. INdIa

Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–[email protected]

Branch Office & Works :No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. INdIa

Phone : + 91-44-2250 0191 / 2250 0175Fax : + 91-44-2250 0175E-Mail : sales–[email protected]

PRecimeasuRe cOntROls Pvt. ltd.

Western india Region Office :Mobile : 09377561070E-Mail : [email protected]

Max.NumberofSwitches 2SwitchType MicroSwitchSwitchRating 5Aat240VACSwitches NormallyOpenTypeorChangeoverTypeAdjustableRange 400C–1050CAccuracyofswitchsetting ±40CofSetValueSwitchDifferentialRange 60C±30CContactType PotentialFreeCableGland(Polyamide/Brass) CableGlandSizePG16HighVoltageTest 2KVAC,50/60Hzfor1Minute,Allterminalstoground

ML :1068

Page 25: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

Precimeasure

ML :1075

DIAL TYPE BI - METALLIC THERMOMETER

Model 1075 (3’’ dial Horiozontal MountinG WitH MaXiMuM pointer)

SpecificationSDial RoundDial3’’AngularSweep 2400

Range 0-1200C(Otherrangesonrequest)Accuracy ±40CBetween400C&1100CGraduation 20CperdivisionInstrumentCase SS-304Case(NaturalFinish).

Model 1073 (4’’ dial top MountinG WitH MaXiMuM pointer)

SpecificationSDial RoundDial4’’AngularSweep 2400

Range 0-1200C(Otherrangesonrequest)Accuracy ±40CBetween400C&1100CGraduation 20CperdivisionInstrumentCase SS-304Case(NaturalFinish)

Model 1074 (6’’ dial top MountinG WitH MaXiMuM pointer)

SpecificationSDial RoundDial6’’AngularSweep 2400

Range 0-1200C(Otherrangesonrequest)Accuracy ±40CBetween400C&1100CGraduation 20CperdivisionInstrumentCase SS-304Case(NaturalFinish).

ML :1073 / 1074

BI-M

ETA

LLIC

Page 26: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

ML :1078

1. Protectionclass: IP55asperIEC60529CAT2.

2. SaltSprayTest: Model-1068/1070/1071 Forpolysterpowdercoating

500HrsasperDIN50021Standard

all the Models type tested for :

Model 1078 (3’’ dial top MountinG WitH MaXiMuM pointer)

SpecificationSDial RoundDial3’’AngularSweep 2400

Range 0-1200C(Otherrangesonrequest)Accuracy ±40CBetween400C&1100CGraduation 20Cperdivision

InstrumentCase SS-304Case(NaturalFinish).

ML :1079

Model 1079 (3’’ dial entry at anGle 450 WitH MaXiMuM pointer)

SpecificationSDial RoundDial3’’AngularSweep 2400

Range 0-1200C(Otherrangesonrequest)Accuracy ±40CBetween400C&1100CGraduation 20CperdivisionInstrumentCase SS-304Case(NaturalFinish).

Registered Office & Works :No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. INdIa

Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–[email protected]

Branch Office & Works :No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. INdIa

Phone : + 91-44-2250 0191 / 2250 0175Fax : + 91-44-2250 0175E-Mail : sales–[email protected]

PRecimeasuRe cOntROls Pvt. ltd.

Western india Region Office :Mobile : 09377561070E-Mail : [email protected]

Page 27: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

Precimeasure

ML :2241B

Model 2241B & 2242 WindinG teMperature indicator / controller for dry type tranSforMerS

application :MODEL2241B/2242/2244T3isdesignedformonitoringthetemperaturesofL.V.windingsoftheDry-TypeTransformer/CastResinTransformers.Itwilldisplaywindingtemperaturesandtakenecessarycontrolactionaspersetanddifferentialvaluesprogrammedbytheuser.Theprotectionsystemalsorecordsmaximumtemperaturesandwilldisplaythesamealongwithcorrespondingchannelnumberwheneverrelevantpushbuttonispressed.

Salient featureS :

a PowerlinefilterwithFuseisincorporatedintheinputofthepowersupplytoprotecttheequipmentfromHighEnergySurgeandElectricalFastTransient.

a HighScanningSpeed

a RemoteIndication&DataAcquisitionfacilitywithburdenupto600ohms.

a OptionalRS-485MODBUSRTUCommunication

ML :2242

SpecificationS Model 2241B Model 2242TemperatureSensorinput

RTD(Pt-100DIN43760) KTypethermocouples

No.ofSensorinputs Four,Eight&Twelve ThreeNo.ofSet-points Three(Fan,AlarmandTrip) Four(Alarm,Trip,Fan1,

Fan2)Range 00C-3000C 00C–2500CResolution 0.10C 10CAccuracy ±10C ±0.8%,onecountunder

normalconditions.DisplaySpeed UserSettable(1-99Seconds) 5SecondsDisplay SixNos.0.5’’SevenSegmentLEDs Fournos0.5”SevenSeg-

mentLEDsAuxiliarySupplyVoltage 90-260VAC/DC 0-20VACor0-240VACOutput AnalogueoutputDC4-20mA

(Maximumburden600Ohms)AnalogueO/PDC0-1mA(10000Ohms)4-20mA(600Ohmsburden)

Communication IsolatedRS-485MODBUSRTUCommunication(Optional).

RS-485&RS-232Communication

ContactRating@ResistiveLoad

5A@220VAC/5A@30DC Alarm&Trip10A@120VAC&8A@240VAC,Fan1&Fan230A@120/240VAC

PowerConsumption 5Watts 8WattsWeight 2Kgs.Approxwithoutpackingbox 2kgsApprox.without

packingboxEnclosure AluminiumPressureDiecasting

enclosure,powdercoatedallsideswithacrylicviewingwindow,IP-55

PanelMountthruCutoutIndoorMountingonly

Operatingconditions Temp:-300Cto700C Temp:-300Cto550C

Electronic Temperature Controllers

Model:2241B

1. ColdandDryTest: -30°Cto+70°C

2. VibrationTest: Amplitude1mm,

frequency50Hz,1Hr/X,Y,Zaxis

Model:2242

1. ShockTest: 11ms/15gProcedureasperthe

IS:13779(12shots)2. VibrationTest: Amplitude0.5mm,

Frequency05to50Hz,02sweeps/X,Y,Zaxis

type tested for

ELEC

TRO

NIC

Page 28: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

SpecificationS TemperatureSensorinput RTD(PT-100DIN43760)No.ofSensorinputs oneNo.ofSet-points Two(Alarm,Trip)Range 00C–2000C(OtherRangesonRequest)Resolution 10CAccuracy ±1%DisplaySpeed -Display Threenos0.5”SevenSegmentLEDsAuxiliarySupplyVoltage 90-260VAC/DC(OthervoltagesonRequest)Output AnalogueoutputDC4-20mA(Maximumburden600Ohms)Communication -ContactRating@ResistiveLoad 5A@220VAC/5A@30VDCPowerConsumption 2WattsWeight 0.5kgsApprox.withoutpackingbox.Enclosure 96SqmmABSBoxEnclosurePanelMountthroughCutout,

IP-20Operatingconditions Temp:00Cto600C

SpecificationSTemperatureSensorinput RTD(PT-100DIN43760)No.ofSensorinputs FourNo.ofSet-points Three(Fan,AlarmandTrip)Range -20to+3000C/0-3000CResolution 10CAccuracy ±20CDisplaySpeed UserSettable(1-30Seconds)Display 4Nos.0.5’’SevenSegmentLEDsAuxiliarySupplyVoltage 90-260VAC/DCOutput AnalogueoutputDC4-20mA(Maximumburden600Ohms)Communication RS-485MODBUSRTUCommunication(Optional)ContactRating@ResistiveLoad 5A@220VAC/5A@30VDCPowerConsumption 5WattsWeight 0.5KgsApproxwithoutpackingEnclosure 96SqmmABSBoxEnclosurePanelMountthroughCutout,

IP-20Operatingconditions Temp:00Cto600C

ML : 2253

ML : 2244T3

Model 2244t3 & 2253 WindinG teMperature indicator / controller for dry type tranSforMerS

application :

MODEL2244T3&2253isdesignedformonitoringthetemperaturesofL.V.windingsoftheDry-TypeTransformer/CastResinTransformers.Itwilldisplaywindingtemperaturesandtakenecessarycontrolactionaspersetanddifferentialvaluesprogrammedby the user. The protection systemalso recordsmaximum temperatures andwill display the samealongwith correspondingchannelnumberwheneverrelevantpushbuttonispressed.

Salient featureS :

a PowerlinefilterwithFuseisincorporatedintheinputofthepowersupplytoprotecttheequipmentfromHighEnergySurge andElectricalFastTransient.

a HighScanningSpeeda RemoteIndication&DataAcquisitionfacilitywithburdenupto600ohms.a OptionalRS-485MODBUSRTUCommunication

Electronic Temperature Controllers

Registered Office & Works :No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. INdIa

Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–[email protected]

Branch Office & Works :No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. INdIa

Phone : + 91-44-2250 0191 / 2250 0175Fax : + 91-44-2250 0175E-Mail : sales–[email protected]

PRecimeasuRe cOntROls Pvt. ltd.

Western india Region Office :Mobile : 09377561070E-Mail : [email protected]

Page 29: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

Precimeasure Electronic Temperature Controllers

Specification :

deScription detailSTemperatureSensorinput RTD(Pt–100DIN43760)No.ofsensorinputs ONECTSecCurrentInput 1.0Ato5.0A(UserSelectable)TemperatureRise 10Cto450C(UserSelectable)No.ofSet-pointsOTI TwoRelaysforAlarmandTrip(1C/OSPDTRelay

contacts)No.ofSet-pointsWTI FourRelaysforAlarm,Trip,Fan1andFan2

(1C/OSPDTRelaycontacts)ContactRating 5A@220VAC/5A@30VDCResistiveLoadRange 0-1500CResolution 0.10CAccuracy ±10CDisplay 0.5SevenSegmentLEDDisplayAuxiliarySupplyVoltage 90-260VAC/DCSignalOutputs TwoanalogueOutputs(4-20mASuitablefor600

OhmsBurdon)Each1No.PowerConsumption 5Watts(Max.)Weight 2KgsApprox.withoutpackingEnclosure AluminiumPressureDieCastingenclosure,

powdercoatedwithacrylicviewingwindow,IP-55Communication RS-485MODBUSRTU(Optional)OperatingTemperature -300Cto700C

Model 2243a oti / Wti teMperature indicator / controller

application :ThisschemeisusedtoIndicateOil&WindingTemperatureoftheoil–immersedtransformers.RelaysareprovidedforAlarm,TripandCoolerDuties,areoperatedasperthesetvalue.4-20mADCsignaloutputsareprovidedseparatelyforOTI&WTIforRemoteIndicationorSCADAPurpose.TheSystemhasthefacilitytostorethemaximumtemperatureattained.

ScHeMe conSiStS of :1.PT-100Sensor1No.2.ElectronicTemperatureController1No.3.ThermometerPocket1No.(Optional)

ML : 2243A

ML : 2246

Model:2243A

1. ColdandDryTest: -30°Cto+70°C

2. VibrationTest: Amplitude1mm,

frequency50Hz,1Hr/X,Y,Zaxis

type tested for

Model 2246 tap poSition indicator

SpecificationS Model 2246SignalInput Resistance(1Kohmsperstep)Range 1-39Position(Usersettable)Display 3nos.0.5”7SegmentLEDSAuxiliarySupplyVoltage 90-260VAC/DCOutput Foursetsof4-20mADC(Maximum

Burndon600Ohms)Communication RS-485ModbusRTUCommunication

(Optional)PowerConsumption 5Watts(Max.)Weight 0.5KgsApprox.withoutpackingEnclosure 96sqmmABSBoxEnclousurePanel

MountthroughcutoutIP-20OperatingTemperature 00Cto600C

ELEC

TRO

NIC

Page 30: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

Electronic Temperature Controllers

electronic type

Model 2220-r1 & 2220-r2 teMperature indicatorAPPLICATION:PRECIMEASUREElectronicInstrumentsaredesignedtoindicatetheTopOilTemperature/WindingTemperatureoftheoil-immersedtransformersinremotecontrolroom.Thisschemehas2Nosof4-20mADCSignaloutputsproportionaltothetemperaturerange.SignalOUTPUT–1isconnectedtoanindicatorforindicatingtemperatureatremoteandOUTPUT–2canbeconnectedtoRecorderorDataAcquisitionSystem.

ScHeMe conSiStS of : 1. PT-100Sensor1No.

2. CurrentConverterUnit1No.

3. RemoteIndicator1No.

4. ThermometerPocket1No.(Optional)

SpecificationS :

Sl. deScription Model 2220 – r1 Model 2220 – r2

1 pt 100 SenSor aSSeMBly

a. Element:Simplex,3wiresystem/Duplex,6WireSystem

b. Tolerance:DIN43760,Class‘B’

2 current conVerter unit WitH poWer Supply unit

a SignalInput:PT100RTD,Simplex3wire

b AuxiliarySupply:90–260VAC/DC

c SignalOutputs:4–20mADCcorrespondingtotemperaturerange

d BurdenonOutputSignal:600Ohmsmaximumincludingloopresistance

e AccuracyofSignalOutput:±1%ofF.S.D.

f Degreeofprotectionofenclosure IP-55 IP-40g Casing AluminiumCasting. ABS,DINEnclosureBox.

3 reMote indicator

a Type:4digits,0.5’’SevenSegmentLED’s

b AuxiliarySupply:90–260VAC/DC

c Temperatureindicatorrange:0-1500C(Otherrangesonrequest)

d Resolution:0.10C

e Degreeofprotectionofenclosure:IP-20

Model:2220-R1&2220-R21.2220-R1,Protectionclass:IP55asperIEC60529CAT2.2.2220-R2,Protectionclass:IP40asperIEC60529CAT23.ColdandDryTeast:-30°Cto+70°C4.VibrationTest:Amplitude1mm,frequency50Hz,1Hr/X,Y,Zaxis

5.EMI/EMCTest:a)ElectrostaticDischargeImmunityTestasperIEC61000-4-2,2001b)ElectricalFastTransientImmunityTestasperIEC61000-4-4,2004c)HighEnergySurgeImmunityTestasperIEC61000-45,2005

type tested for

Registered Office & Works :No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. INdIa

Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–[email protected]

Branch Office & Works :No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. INdIa

Phone : + 91-44-2250 0191 / 2250 0175Fax : + 91-44-2250 0175E-Mail : sales–[email protected]

PRecimeasuRe cOntROls Pvt. ltd.

Western india Region Office :Mobile : 09377561070E-Mail : [email protected]

Page 31: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

Precimeasure

ordering information

Model 1080 - 4" & 6"

Model: 1090Size: 1” B.S.p Male

SpecificationS :

LiquidinTank TransformeroiltoIS335andoranyotherOil

WorkingTemperature -30to100°Cofoil

WorkingPressure 0to4Kg/Cm2

WorkingEnvironment IndoororOutdoor

indication :

Dialsize 4"&6"RoundColorBlackmarkingonwhitebackgroundoranyothercombinationasrequired.StandardRedLineIndicationforMin.toEmptyLevel

AngularSweep 300°

float (SenSor) and arM :

Material Float:PolyurethaneFoam/Brass

FloatArm:Brass

Float-ArmLength FixedLengthasgivenbyCustomer

Travel Max.45°Below&Abovefromthecentre

Margin LeaveMin.40mmbeyondlower&higherlimitmarkingstoavoidstrikingoffloattobottom&topofconservator.

SWitcH :

Type Microswitch

ContactRating 5A@240VAC,0.25A220VDC

MAGNETIC OIL LEVEL GUAGE

application:MagneticOilLevelGauge(MOG)isusedtoMeasureOilLevelofoilfilledTransformers&OilfilledTanks.

ModelNo 1080/4

FloatArmLength

ConservatorDiameter

MountingVertical/Inclined

IfInclinedMentionAngle

AndotherSpecificationsifany

type tested for

1. Protectionclass: IP55asperIEC60529CAT2.

2. VibrationTest: Amplitude1mm,frequency50Hz,

1Hr/X,Y,Zaxis

preSSure relief deVice

application:PRDisasafetydeviceforthedistributiontransformerupto5000KVA,OLTCandothersimilarequipments.ThisPRDisusedtopreventheavydamagesofthetankincaseofsuddenriseofinternalpressure.

operatinG preSSure :OperatingPressurerangeavailablefrom0.2to0.7kg/sq.cmwithtolerance±0.05kg/sq.cm.

• Safespringloadeddesignthatdoesnotrequireexternalpowersupplyforoperation• Positivedownwarddirectionalflowlimitshorizontalsprayingofhotoilonadjacentequipment• Largediametertopcoverwithimprovedoperatingforceprovidingbetterprotection• Transportsafetycliptopreventoilspillageduringtransportationofoilfilledtransformers• AvailableinbrassorZamakbodyconstruction

General features

OTH

ERS

Page 32: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.com

PrecimeasureBEARING / AIR

TEMPERATURE INDICATOR / CONTROLLER

application : ThisInstrumentsisusedformonitoringandcontrollingtheBearing/AirTemperatureoftheMotorandGenerators

Model 1006 - Btd/atd

SpecificationS :

TemperatureRange 0-150°C(OtherRangesonrequest)

DialSize 150mm(6")Round

DialAngularSweep 270°

DialGraduations 2°CperDivision

AccuracyClass ±1.5%ofF.S.D

Max.No.ofSwitches 2

SwitchSetting 15%to85%

SwitchContactRating 5Aat250VAC&0.5Aat220VDC

SwitchDifferential 3°C±2C(Fixed)

AccuracyofSwitchSetting ±2.5°CofSetValue

Max.CapillaryLength Upto15Meters

Mounting Flush/Projection

1. Protectionclass: IP55asperIEC60529CAT2.

2. VibrationTest: Amplitude1mm,frequency50Hz,

1Hr/X,Y,Zaxis

3. MicroSwitchratingTest:

5A@250VAC&0.5A@220VDC

type tested for

Registered Office & Works :No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. INdIa

Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–[email protected]

Branch Office & Works :No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. INdIa

Phone : + 91-44-2250 0191 / 2250 0175Fax : + 91-44-2250 0175E-Mail : sales–[email protected]

PRecimeasuRe cOntROls Pvt. ltd.

Western india Region Office :Mobile : 09377561070E-Mail : [email protected]

portaBle oil BatHModel HoB -180ForOTI&WTICaliberation

diSplay Specification

Range Ambient+5°CTo180°C

Display Dual4DigitDisplay

DisplyResolution 0.1°C

Temp-Setting WithPushButtonDataEntry

GENERALSPECIFICATION

SystemAcuracy BetterThen±0.5%OfReadingOr±0.5%C(WhichEverIsHigher)

Stability BetterThen±0.5%C

SetPointArchiveTime Approx.30Minutes

StabilizationTime Approx.20MinutesAfterReachingSetValue

electrical Specification

PowerConsumption 300WattsApprox.

PowerSupply 230Vac,50Hz

pHySical Specification

Dimensions 6”(W)X14”(H)X9”(L)

Weight 5.5KgsApprox.

HeatingMedia SiliconOil/TransformerOil

OilVolume 1.5LtrApprox

WellDepth 160mm

Accessories DrainLocking‘O’Ring

Stirring ByMechanicalStirrerOfIgMotor

Page 33: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.comPRecimeasuRe

ScH

eMe

dra

Win

G

SCH

EME

Page 34: General features - Precimeasure Controls Specifications.pdf• The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are

www.precimeasure.comPRecimeasuRe

ScH

eMe

dra

Win

G