genel eğitim notları özetleri - · pdf filegenel eğitim notları özetleri...

of 103 /103
Genel Eğitim Notları Özetleri 09/2007 Satış Sonrası Hizmetler Yöneticiliği http://www.demirdokum.com.tr

Author: vunhu

Post on 07-Feb-2018

315 views

Category:

Documents


26 download

Embed Size (px)

TRANSCRIPT

  • Genel Eitim Notlar zetleri

    09/2007 Sat Sonras Hizmetler Yneticilii

    http://www.demirdokum.com.tr

  • NDEKLER MTER MEMNUNYET N :.......................................................................................................... 1 KOMB LK ALITIRMA VEYA ARIZA AMALI MTER EVNE GDLDNDE YAPILACAK LEMLER :..2 RNLERN ZERNDE YER ALAN BARKODUN AILIMI :...............................................................3

    DOGALGAZ YAKITLI CHAZLARIN GAZ BAGLANTISI PROSEDR 23 :........................................ 4-5 KOMB ENJEKTR APLARI VE MN.- MAKS. GAZ BASIN DEGERLER :.....................................6 ADEN SERS KOMBLER SESL YANI DURUMUNDA YAPILACAK LEMLER :...................... 7-13 ADEN SOLARS KOMB LM NOKTALARI :................................................................................ 14 ADEN SOLARS SARGON KALSTO NTRON NANOMKS PARAMETRE TABLOSU :...............15-16 ADEN SOLARS TEKNK VERLER TABLOSU :................................................................................ 17 ADEN KOMB KUMANDA PANOSU................................................................................................... 18 ADEN KOMB KART ZERNDEK SERVS AYARLARI : ................................................................. 19 TAYROS KOMB TEKNK VERLER TABLOSU:................................................................................ 20 BACALI VE HERMETK KOMB MONTAJ ARTLARI : ................................................................ 21-27 TAYROS KOMB PARAMETRE AYARLARI :................................................................................ 28-29 SOFAST CE1-FE1 PARAMETRE AYAR TABLOSU: ........................................................................ 30 SOFAST CE1-FE1 ARIZA KODLARI:................................................................................................ 31 SOFAST RC KOMB MONTAJCI VE SERVS AYAR PARAMETRELER:........................................ 32 SOFAST RC KOMB MTER AYAR PARAMETRELER:.............................................................. 33 SOFAST RC KOMB ARIZA KODLARI :............................................................................................ 34 THEMAFAST 1 KOMB SERVS AYAR PARAMETRELER :........................................................ 35-36 THEMAFAST KOMB BACA AYARLARI TABLOSU:.......................................................................... 37 THEMAFAST 2 KOMB SERVS AYAR PARAMETRELER :........................................................ 38-39 SOFAST 335 CE VE 335 FE DP SV AYARLARI :.........................................................................40 VNTO VE THEMAFAST KOMB ARIZA KODLARI :.......................................................................... 41 VNTO KOMB SERVS PARAMETRE AYARLARI : ......................................................................... 42 VNTO KOMB EKRAN KARTI DEGTRLDGNDE YAPILACAK LEMLER : .............................. 43

  • KALSTO KOMB ARIZA KODLARI VE PARAMETRE AYARLARI ( DJTAL:) : ........................... 44-45 KASKAD SSTEM HABERLEME KARTLARI SV AYARLARI :.....................................................46 KASKAT SSTEM UZAKTAN KUMANDA KULLANMA KLAVUZU VE AYARLARI :......................47-52 SARGON PREMKS KOMB ARIZA KODLARI SV AYARLARI BACA GAZI ANALZ :........... .53-56 NANOMKS KOMB ARIZA KODLARI SV AYARLARI BACA GAZI ANALZ :............................57-62 NTRON NANOMKS VE KALSTO KOMB PROGRAM SAAT AYARLARI :.................................63-65 NTRON KOMB ARIZA KODLARI PARAMETRE AYARLARI TEKNK VERLER :........................66-72 GNE ENERJS VE KALORFER SSTEMLERNDE DONMAYA KARI NLEMLER :............73-74 PANEL RADYATRLERN ZERNDEK MALAT TARH BLGS :..................................................75 ARTECH KAT KALORFER KULLANICI AYAR PARAMETRELER :............................................75-76 ARTECH KAT KALORFER SERVS AYAR PARAMETRELER :..................................................76-81 ARTECH KAT KALORFER DG-LPG MEME APLARI VE GAZ BASINLARI :................................81 ARTECH KAT KALORFER DG -LPG DNM SET KODLARI :................................................82 DKM DLMLERN ZERNDE YER ALAN DKM TARH BLGS :............................................82 ARTECH KAT KALORFER BOYLER KT MONTAJI :........................................................................83 ESK TP KAT KALORFERLERNDE BOYLER KT KULLANILMAK STENDGNDE :......................83 COMPACT BACALI OFBEN DG -LPG DNM SETLER :.....................................................84-85 COMPACT HERMETK OFBEN DG-LPG DNM VE PARAMETRE AYARLARI :..............85-86 COMPACT BACALI SE OFBEN ELEKTRK BAGLANTI EMASI :...................................................86 GOLDSTAR ROLE VE EGO EMERSON L TERMOSTAT KOTAK ULARI :...............................87 SHD 90 SOBA TEKNK ZELLKLER :...............................................................................................88 DHS SOBA TEKNK ZELLKLER:.....................................................................................................89 SHD 70 TEKNK ZELLKLER :..........................................................................................................90 SBD SOBA TEKNK ZELLKLER :....................................................................................................91 ADEN KOMB SERVS ARIZA BULMA ZELGES :.....................................................................92-94 TAYROS KOMB SERVS ARIZA BULMA ZELGES :................................................................95-97 YEL RETM KOMBLERDE KULLANILAN ELEKTRONK KART SEM TABLOSU :................98-99

  • 1 09/2007

    MTER MEMNUNYET N,

    Randevunuza kesinlikle sadk kalnz. Randevunuza uyamadnzda mterinize telefon ile

    bilgi veriniz. Mutlaka belge braknz. Kendinizi mterinizin yerine koyunuz. Daima gleryzl olunuz. Mterinizle kesinlikle tartmaynz. Mterinizin sorununa mutlaka zm bulunuz. Hatalarnz kabul ediniz. inizde mutlaka servis kyafetinizi giyiniz kimlik

    kart taknz. Mterinize gereken bilgileri veriniz. alma rtsn kullannz. Galo giyiniz. Sat Sonras Hizmetler Yneticilii

  • 2 09/2007

    KOMB LK ALITIRMA VEYA ARIZA AMALI MTER EVNE GDLDGNDE

    YAPILMASI GEREKEN KONTROLLER 1. a) Kombi doal gazla alcaksa; yerel gaz datm irketinin verecei gaz ama belgesi kontrol edilmelidir.

    LPG ile alacaksa; cihazn LPG'ye ayarl olup olmad, tp ve kollektr balantlarnn uygun yaplp yaplmad kontrol edilmelidir.

    b) Cihaz uygun gaza dnm yaplmamsa; kombi servis bltenine uygun dedantr kullanld ve servis bltenine uygun olarak dnm yaplmaldr.

    2. Gaz vanasndan gaz valfine kadar olan hatta gaz kaa kontrol yaplmaldr. Kontrol gaz kaa dedektr veya sabun kpg kullanlmal, kesinlikle akmak alevi ile kontrol yaplmamaldr.

    3. Kombi ve tesisata su basld kontrol edilmeli, ayet kombide su yoksa uygun basnta su ile doldurulmaldr. Tesisat gidi dn hattnda ki vanalar ak konuma getirilmeli radyatr vanalarnn ak olup olmad kontrol edilmelidir. Radyatrlerde su kaa gzlenirse tesisatnn gelmesi nerilmelidir.

    4. Atk gaz boru balantlar ve atk gaz boru aznn aydnlk boluuna veya kapal bir ortama verilmedii kontrol edilmelidir (atk gaz boru az mutlaka d atmosfere verilmi olmaldr.). Kombinin atk gaz borusunun yeterli gelmedii durumlarda ilave baca uzatma borusu ve dirsei kullanlmsa, yk kayb hesabna uygunluu kontrol edilmelidir. Baca borusu %2 aagya eimli olmaldr.

    5. Kombi otomatik purjr tapas 1-2 tur gevetilmeli, sirklasyon pompa tapas sklerek havas alnmal, bir tornavida yardm ile yol verilerek rahat dnp dnmedigi kontrol edilmelidir. Pompa alma konumu ile kombi maksimum kalorifer suyu scakl seimi tesisat durumuna gre seilmelidir. ( yerden stma veya radyatr gibi )

    6. Elektrik balants kontrol edilmeli, kombinin 50 cm yaknna bir V otomat veya toprakl priz takld grlmelidir. lave kontrol sistemi varsa (oda termostat, program saati gibi) balantlarnn ve yer seiminin doru yapld grlmelidir.

    7. Kombi alrken scaklk ykselmesinin normal olup olmad gzlenmeli, sirklasyon problemi varsa filtreler kortrol edilmelidir. Radyatr balantlar kontrol edilmeli scak suyun stten girdii grlmelidir.

    8. Kombi kulanm suyuna altrlarak yeterli debi ve scaklkda su verdii gzlenmelidir. 9. Kombinin almas ile ilgili kullancya bilgi verilmelidir. 10. Sesli yanma ikayeti iin genleme tank ile arka gvde arasna tampon snger sktrlmaldr. 11. Sesli yan nlemek amacyla elektronik kart zerindeki potansiyometreden (veya ilgili birimden) start basn

    ayar yaplmaldr. Alev yayl brulr zerinde gzlenmeli eer brulrn tamamnda alev yaylmyorsa veya gecikme oluyorsa alev ynlendirme sac taklmaldr.

    12. Fan zerine fan diyaframnn (baca bilezii) takl olup olmad kontrol edilmelidir. Yoksa 17.000 ve 20.000 kcal/hlk kombi iin 41, 26.000 kcal/hlk kombi iin 44 lk diyafram taklmaldr.

    13. Sargon Condense (Youmal) kombi ilk altrmasnda youma suyu drenaj kab ve borusu kontrol edilmelidir. (Youma suyu drenaj hortumu tesisat tarafndan atk su tesisatna verilmesi gerekmektedir.) Baca eimi %2 yukarya doru olmaldr.

    14. Manometre yardm ile kombinin minimum ve maksimum yan g ayarlar yaplmaldr. 17.000 ve 20.000 kcal/hlk DG kombi iin min. gaz basnc 1,7 mbar max gaz basnc 12,7 mbar LPG iinse bu deerler min. 3,2 mbar max 27,7 mbardr. 26.000 kcal/hlk kombi iin ise max deer 15 mbardr.

    15. Kombi 5 kezden fazla arzaya gemise ve elektronik kart kilitlemise (alev yok arzas veriyorsa) kombi ama kapama anahtar kapal konuma getirilmeli, cihazn elektrik beslemesi kesil