geluidreductie door gevels : rekenmethode · geluidreductie door gevels rekenmethode - l aan adres...

89
Geluidreductie door gevels : rekenmethode Citation for published version (APA): Gerretsen, E. (1981). Geluidreductie door gevels : rekenmethode. (Onderzoekprogramma Interdepartementale Commissie Geluidhinder. WG, Woongeluid; Vol. WG-HR-05-02). 's-Gravenhage: Ministerie van Volksgezondheid en Milieuhygiene. Document status and date: Gepubliceerd: 01/01/1981 Document Version: Uitgevers PDF, ook bekend als Version of Record Please check the document version of this publication: • A submitted manuscript is the version of the article upon submission and before peer-review. There can be important differences between the submitted version and the official published version of record. People interested in the research are advised to contact the author for the final version of the publication, or visit the DOI to the publisher's website. • The final author version and the galley proof are versions of the publication after peer review. • The final published version features the final layout of the paper including the volume, issue and page numbers. Link to publication General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights. • Users may download and print one copy of any publication from the public portal for the purpose of private study or research. • You may not further distribute the material or use it for any profit-making activity or commercial gain • You may freely distribute the URL identifying the publication in the public portal. If the publication is distributed under the terms of Article 25fa of the Dutch Copyright Act, indicated by the “Taverne” license above, please follow below link for the End User Agreement: www.tue.nl/taverne Take down policy If you believe that this document breaches copyright please contact us at: [email protected] providing details and we will investigate your claim. Download date: 09. Jul. 2020

Upload: others

Post on 26-Jun-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

Geluidreductie door gevels : rekenmethode

Citation for published version (APA):Gerretsen, E. (1981). Geluidreductie door gevels : rekenmethode. (Onderzoekprogramma InterdepartementaleCommissie Geluidhinder. WG, Woongeluid; Vol. WG-HR-05-02). 's-Gravenhage: Ministerie vanVolksgezondheid en Milieuhygiene.

Document status and date:Gepubliceerd: 01/01/1981

Document Version:Uitgevers PDF, ook bekend als Version of Record

Please check the document version of this publication:

• A submitted manuscript is the version of the article upon submission and before peer-review. There can beimportant differences between the submitted version and the official published version of record. Peopleinterested in the research are advised to contact the author for the final version of the publication, or visit theDOI to the publisher's website.• The final author version and the galley proof are versions of the publication after peer review.• The final published version features the final layout of the paper including the volume, issue and pagenumbers.Link to publication

General rightsCopyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright ownersand it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights.

• Users may download and print one copy of any publication from the public portal for the purpose of private study or research. • You may not further distribute the material or use it for any profit-making activity or commercial gain • You may freely distribute the URL identifying the publication in the public portal.

If the publication is distributed under the terms of Article 25fa of the Dutch Copyright Act, indicated by the “Taverne” license above, pleasefollow below link for the End User Agreement:www.tue.nl/taverne

Take down policyIf you believe that this document breaches copyright please contact us at:[email protected] details and we will investigate your claim.

Download date: 09. Jul. 2020

Page 2: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

WG - HR - 05 - 02

- geluidreductie door gevels - Rekenmethode

- Schalldammung durch Fassaden -Berechnungsverfahren

Noise reduction by facades - Calculation method

Methode de cal cui de la reduction du bruit par les fac;ad'es

.2J~~ INTERDEPARTEMENTALE

COMMISSIE GELUIDHINDER

56.w-bcJlVl ~. ~D l ~ ~ ~ \

8')00 41"1 ,1.1 1. I

i \

Page 3: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

I 1 Rapport nr. WG-HR-05-Q2 7 Archief nr.

2 Sub-titel Rapport 8 Datum Publicatie augustus 1981 "Geluidreductie door gevels Rekenmethode"

9 Rapport nr. Instituut 007.794/4

3 Schrijver(s) 10 Tijdschrijf nr. Ir. E. Gerretsen

4 Uitvoerend Instituut, Naam I Adres Technisch Physische Dienst (TPD-TNO-TH) Stieltjesweg 1, Delft

11 Opdracht nr.

12 Rapporttype en periode

5 Opdrachtgever(s) Hoofdrapport 1979 -1981

Ministerie van Volksgezondheid en Milieuhygiene

6 TitelOnderzoekproject Controle geluidisolatie woningen

13 Samenvatting

14

In deze publicatie wordt een rekenmodel beschreven waarmee het genormeerd (geluiddruklni­veauverschil van gevels in octaafbanden kan worden berekend met betrekking tot diverse bronnen van buitengeluid zoals wegverkeer, railverkeer, luchtverkeer, industrieen, recreatie­inrichtingen. Tevens worden enkele mogelijkheden aangegeven om het rekenresultaat in eEln getal uit te drukken. In het rekenmodel wordt rekening gehouden met de volgende factoren: - oppervlakte en geluidreducerende eigenschappen van de samenstellende delen van de gevel - geluidlekken via naden en kieren - gevelstructuur (balcons, galerijen e.d.) - variaties over de gevel in het geluiddrukniveau buiten Voor de meeste bij gevels voorkomende materialen en constructies zijn karakteristieke geluid­reducerende eigenschappen, veelal in de vorm van formules, bij het rekenmodel opgenomen. Het rekenmodel is verwerkt in een computerprogramma hetgeen eveneens is gegeven met een korte beschrijving en een beschrijving van de invoergegevens en uitvoer.

Begeleidingscommissie if, W.K. v,d. Lingen ing, J.O. Dekker (79) if. C.J. Padmos (,80l if. H .M. Croes ir. J.N.M. v. Rooijen R.E. Donkersloot ing. W. de Graaf ing. J.M.M. Jenissen drs. J.P. Kaper ir. A.C. v.d. Linden

Min.vanV&M - Min. van V&M - Min. van V&M - Min. van V&M - Min. van VRO - Min.v.V&W

DHV - Rijksgeb, dienst Z-H - IMG-TNO - Rijksgeb. dienst Z-H

15 Bijbehorende . Rapporten

TPD - rapportnr. 007.79412, Vergelijking met meetresul­taten van drie verschillende uitwerkingen van een rekenmodel voor de gevel­geluidreductie

16 Aantal biz. 65 biz.

17 Prijs fl. 10,~

!

Page 4: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

VOORWOORD,

Binnen de werkingssfeer van de wet geluidhinder worden de maximaal

toelaatbare geluidniveaus in de woonomgeving aangegeven.

Deze geluidniveaus, de grenswaarden, voor het geluidniveau buiten de

woningen maken het mogelijk beslissingen te nemen over

~et al of niet bouwen van woningen in nieuwe situaties met veel lawaai,

- het aanbrengen van extra geluidwering bij gebouwen in bestaande situaties.

In het kader van de gefaseerde uitvoering van de wet' geluidhinder worden

bij algemene maatregelen van bestuur(AmvB's)de wettelijke bepalingen

vQor nieuwe en bestaande situaties van kracht.

- per 1 januari 1982 treedt het Besluit grenswaarden binnen zones langs wegen

(artikel 82-86) van de Wet geluidhinder in werking voor "nieuwe situaties

langs wegen"

- per 1 september 1982 treedt hat Besluit grenswaarden binnen zones rond

industrieterreinen (artikel 47 tim 68 van de wet geluidhinder)in werking voor

"nieuwe en bestaande situaties bij industrieterreinen"

- terwijl de inwerkingtreding van de Afdeling Bestaande situaties langs

wegen volgens planning nog enkele jarenop zich zal latenwachten.

De systematiek van de wet gelUidhinder zal in veel gevallen lei den tot

de noodzaak om geluidwerende voorzieningen te treffen aan waarvoor

€len hogere geluidbelasting wordt toegelaten dan de grenswaarde van

50 dB(A).

De geluidisolatie eisen die hierbij veiplicht worden gesteld zullen in het

kader van de AmvB ex artikel 3 van de Woningwet worden opgenomen.

V~~r de uitvoering van deze AmvB is het noodzakelijk om afspraken te maken

over

de wijze van berekenen van geluidwerende kwaliteit van gevelconstructies;

- de meetmethoden voor de controle van de geluidwerende kwaliteit van de

uitgevoerde constructies.

In het kader van de ICG-onderzoekprogramma's Woongeluid en Verkeerslawaai

zijn de akoestische gegevens van gevel onderdelen, zoals ramen, borstweringen

en suskasten reeds bestudeerd,.

In'verband hiermee kan verwezen worden naar de rapporten WG-DR-IO-02, VL-DR-

12-01 en VL-DR-12-02. ,

In de thans gereed gekomen rapporten WG-HR-05-01 en - 02 zijn reken- en

Page 5: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

2 -

meetmethoden bestudeerd voor het vaststellen van de geluidniveau's

binnen woningen, uitgaande van vastgestelde geluidniveau'sbuitende

woningen.

De resultaten van deze rapporten worden verwerkt in

- de AmvB ex artikel 3 van de Woningwet, het "Besluit geluidwering gebouwen",

- de beschikking ex. artikel 67 en 102 van de Wet geluidhinder ter bepaling

van het geluidsniveau binnen woningen.

Op grond van ervaringen uit de praktijk bestaat de indruk dat het mogelijk ,

is om voor het berekenen van de geluidisolatie van.gevels gebruik te maken

van vereenvoudigingen. Gedacht kan bijvoorbeeld worden aan het hanteren

van een standaard spectrum voor weg verkeerslawaai in plaats van verschillende

spectra per verschillende verkeerssamenstelling.

Deze vereenvoudigingen zullen in de wettelijke regelingen worden verwerkt.

Met de hier genoemde regelingen is het wettelijke instrumentarium gegeven

voor het oplossen van de problematiek van het weg verkeers- en industrie­

lawaai in de gebouwde omgeving.

De voorzitter van de leG subcomillissie Woongeluid,

f;k~~tA ir. W.K. van der Lingen

Page 6: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

Geluidreductie door gevels - Rekenmethode.

SAMENVATTING ============

In deze publikatie wordt een rekenmodel bescllreven waarmee het ge­

normeerd (geluiddruk) niveauverschil van gevels in octaafbanden

kan worden berekend met betrekking tot diverse bronnen van buiten­

geluid zoals wegverkeer, railverkeer, luchtverkeer, indrustrieen,

recreatie-inrichtingen).

Tevens worden enkele moge~ijkheden aangegeven om het rekenresultaat

in een getal uit te drukken.

In het rekenmodel wordt rekening gehouden met de volgende factoren:

- oppervlakte en geluidreducerende eigenschappen van de samenstel-

lende delen van de gevel

- geluidlekken via naden en kieren

- gevelstructuur (balcons, galerijen e.d.)

- variaties over de gevel in de geluiddrukniveau buiten

Voor de meeste bij gevels voorkomende materialen en constructies

zijn karakteristieke geluidreducerende eigenschappen, veelal

in de vorm van formules, bij het rek'enmodel opgenomen.

Het rekenmodel is verwerkt in een computerprogramma hetgeen eveneens

is gegeven met een korte beschrijving en een beschrijving van de in­

voergegevens en uitvoer.

Schalldammung durch Fassaden - Berechnungsverfahren

In dieser Ver6ffentlichung wird ein Rechenmodell beschrieben,

mit dessen Hilfe die normierte Schalldruckpegeldifferenz an

Fassaden in Oktavbandern berechnet werden kann. Das Aussengerausch

kann dabei von verschiedenen Quellen herstammen, z.B. vom Strassen­

verkehr, Schienenverkehr, Luftverkehr, von der Industrie oder

von Erholungseinrichtungen. Ausserdem werden einige M6glichkeiten

angegeven, das Berechnungsergebnis in einen einzigen Wert auszu­

drUcken.

Page 7: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

- 2 -

Das Rechenmodell berucksichtigt folgende Faktoren:

- Oberflache und schalldammung der Fassadenteile

- Schalldurchlassigkeit von Fugen und Ritzen

- Gestaltung der Fassade (Balkons, Vorbauten und dergl.)

- Schalldruckpegeldifferenz an der Aussenseite der Fassade

Die charakteristischen Schalldammungseigenschaften der meisten

fur Fassaden verwendeten Baumaterialien sind ebenfalls aufgefurt,

hauptsachlich in Form von Formeln ..

Die Veroffentlichung enthalt ferner eine kurze Beschreibung eines

Computerprogramms, das fur die Anwendung des Rechnmodells erstellt

wurde, sowie eine Ubersicht Uber.die Eingabe- und Ausgabedaten.

Noise reduction facades - calculation method.

A model is described which is used to calculate the standardized

level difference of facades (in octave bands) with regard to

various sources of outdoor noise such as road traffic, railtraffic,

airtraffic, industries, recreational facilities etc. The report

also gives a number of ways of

fig~re.

the results in a single

The model takes the following into account:

- surface and nois-reducing properties of the facade elements;

- noise leaks through joins and slits;

structure of the facade (balconies etc.);

variations in external sound pressure level at various parts of

the facade ..

The model also contains characteristic nois reduction properties ,

for the material most commonly used for facades, expressed

as equations.

Page 8: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

- 3 -

de mesure de la reduction du bruit cause

par la circulation routiere.

RESUME ======

Le rapport decrit les methodes de me sure permettant de determiner

la difference de niveau de pression sonore (en bandes d'octave)

selon les fa~ades en ce qui concerne Ie bruit de lacirculation

dansune situation donnee, de fa~on a pouvoir etablir grace a la reduction du bruit ainsi determine un rapport direct entre les

niveaux de pression sonore a l'exterieur et a l'interieur.

La premiere methode se base sur la circulation routiere comme source

sonore, la seconde utilise une source sonore artificielle, dependant

de la situation a une on a plusieurs positions Ou bien une source

mobile.

Plusieurs possibilites sont proposees pour exprimer Ie resultat des ,

mesures en une grandeur unique. Une arinexe est consacree a des

methodes de mesure ~ mesures a faible distance dela fa~ade et mesure

recipraques - qui permettent d'analyser plus specifiquementles

proprietes de reduction sanore des differentes parties de la fa9ade.

Page 9: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

TPD technisch physische dienst tno - th .

N~: 007.794/4

Afd.; Geluid

Behandeld: ir. E. Gerretsen

Datum': 26 juni 1981

RAPPORT

r

GELUIDREDUCTIE DOOR GEVELS

REKENMETHODE -

L

AAN

adres Stieltjesweg 1 postadres Postbus 155

2600 AD Delft telefoon (015) 569300

telex )(3t!XWx 38091

..J

• Ministerie van Volksgezondheid

en Milieuhygiene

Leidschendam

Oit rapport mag sle,hlS woordelijk en in zijn geheel worden

gepubliceerd; VOOf reclame aileen na schriftelijke toestemming.

Page 10: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad I

SAMENVATTING ============

In deze publikatie wordt een rekenmodel beschreven waarmee het genormeerd

(geluiddruk)niveauverschil van gevels in octaafbanden.kan worden berekend

met betrekking tot diverse bronnen van buitengeluid zoals wegverkeer,

railverkeer, luchtverkeer, industrieen, recreatie-inrichtingen).

Tevens worden enkele mogelijkheden aangegeven om het rekenresultaat in

een getal uit te drukken.

In het rekenmodel wordt rekening gehouden met de volgende factoren:

- oppervlakte en geluidreducerende eigenschappen van de samenstellende

delen van de gevel

- geluidlekken via naden en kieren

- gevelstructuur (balcons, galerijen e.d.)

- variaties over de gevel in het geluiddrukniveau buiten

Voor de meeste bij gevels voorkomende materialen en constructies zijn

karakteristieke geluidreducerende eigenschappen, veelal in de vorm van

formules, bij het rekenmodel opgenomen.

Het rekenmodel is verwerkt in een computerprogramma hetgeen eveneens is

gegeven met een korte beschrijving en een beschrijvingvan de invoergegevens

en uitvoer.

/

Page 11: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

l.

2.

3.

3.1

3.2

3.2.1

3.2.2

3.2.3

3.2.4

3.3

4.

4. 1

4.2

4.3

4.4

5.

5. 1

5.2

6.

6. 1

6.2

IN HOUD

Inleiding

Toepassingsgebied

Principe van de berekening

Algemeen

Invoergegevens

Geluidreducerende eigenschappen geveldelen

en elementen, R en D n

Gevelstructuurcorrectie C g

Kierfactor K

Geventileerde gevel

Stylering van gevel en vertrek

Gebruik bij specifieke geluidbronnen

Gebruik bij wegverkeer

Gebruik bij railverkeer

Gebruik bij luchtverkeer

Gebruik bij overige geluidbronnen

Geluidisolatiegegevens

Karakteristieke gegevens

Gebruik meetgegevens

Toepassing rekenresultaten

Een-getals aanduiding

Geluidniveau binnen

Literatuur

Bijlage A Computer-rekenprogramma v~~r de

geluidreductie door gevels

Bijlage B Waarden van enkele correcties

en de kierfactor

Bijiage C K&rakteristieke geluidreducerende

eigenschappen van geveldelen en

geveIeIementen

Bijiage D Referentiespectrum

Bijiage E Rekenvoorbeelden

BIz

1

2

4

4

7

7

blad III

8

9

10

11

13

13

13

14

15

16

16

17

19

19

20

21

At

HI

Cl

D.l

El

Page 12: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

brad 1

1. INLEIDING =========

In deze publikatie wordt een methode behandeld voor de berekening

van de geluidreductie door gevels met betrekking tot diverse bron­

nen van buitengeluid.

De rekenresultaten kunnen dienen om:

- de akoestische,kwaliteit van e~n gevel te voorspellen

- de invloed op de geluidreductie van, wijzigingen in een gevel-

constructie dan weI van alternatieve gevelconstructies aan te

geven

he,t resulterende geluidniveau in een vertrek te voorspellen bij

een gegeven geluiddrukniveau buiten.

De rekenresultaten zijn direct vergelijkbaar m~t meetresultaten

volgens de in [ '1 ] aa~gegeven meetprincipes, daar uitgewerkt

voor wegverkeersgeluid.

De rekenmethode wordt gegeven voor berekeningen in octaafbanden.

Het rekenresultaat kan worden uitgedrukt in een getal, zoals het

gevelverschil in geluidniveau-A voor een gegeven buitenspectrum.

Ais het doel van de berekeningen deze laatste grootheidis, kan in

principe volgens dezelfde methode ook direct in dB(A) worden gere­

kend mits de geluidreducerende eigenschappen van de gevelonderdelen

ook bekend zijn als A-gewogen groothedenvoor het betreffende spec­

trum.' Voor globale berekeningen kan het voldoende zijn hierbij te

rekeneri voor ee~ globaal met het feitelijke spectrum overeenk~mend

spec trum, een z. g. gestandaardiseei-d referentiespec trum vQor een

bepaalde bron van buitengeluid.

Oak andere een-getals grootheden, by. de gewogen geluid­

isolatie R worden voor een globale b~rekening weI toegepast. , w' ,

E~n dergelijke berekening met een-getals grootheden wordt hier niet

expliciet behandeld.

Voor berekeningen in A-gewogen grootheden, toegepast op wegverkeers­

geluid kan '(lorden verwezen naar de brochure ItVerkeerslawaai en

Woningenlt [ 2 ] •

Page 13: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad 2

2. TOEPASSINGSGEBIED =================

Het principe van de rekenmethode is toepasbaar v~~r geluid van aIle

soorten geluidbronnen buiten, zoals wegverkeer, railverkeer,luchtver­

ke.er, industrieen en recreatie-inrichtingen.

De berekening is van toepassing op de geluidreductie door de gezamen­

lijke buitenbegrenzingen van een vertrek, verder aan te duiden als

de geve!.

Hierbij wordt onder een buitenbegrenzing de totale constructie ver­

staan die vanuit het vertrek gezien de scheiding vormt met de buiten­

omgeving, voorzover deze constructie als een 1 is te beschouwen.

Een dergelijke gevel bestaat in het algemeen uit het geveIvlak, het

deel van de constructie dat direct aan het vertrek grenst, en daar­

buiten balkons, galerijen en dergelijke.

Niet tot de gevel behoren derhalve al dan niet aangebouwde muren en

bergruimten of muren en vertrekken als bij z.g. patio-woningen.

Een geveiviak kan opgebouwd zijn uit diverse constructies. V~~r de

meest gebruikelijke constructies wordt aanbevolen de karakteristieke

isolatiegegevens van deze constructies t.oe te passen, welke in deze

publikatie ~orden beschreven.

Andere gegevens v~~r deze constructies of gegevens over afwijkende

constructies kunnen worden toegepast voorzover deze voldoen aan de

daaraan Ide eisen.

De nauwkeurigheid van het berekeningsresuitaat is van verschiIIende

factoren afhankeIijk. Dit betreft enerzijds de nauwkeurigheid van

de gebruikte constructiegegevens, waaronder ook de geluidiekken via

kieren en naden zijn te verstaan, anderzijds de complexiteit van de

gevelconstructie en de geluidbronsituatie.

Page 14: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad3

Ten gevolge van de eerste factor,zal de nauwkeurigheid Cstandaard­

afwijking van het verschil) in het algemeen niet groter kunnen zijn

dan! 3 dB per octaafband en ca. + 2 dB voor het gevelverschil in

geluidn~veau-A.

Een duidelijk grotere onnauwkeurigheid moet met name worden verwacht

bij bijzondere gevelconstructies en bij situaties waarbij het geluid

vrijwel uitsluitend invalt onder een grote hoek ten opzichte van de

normaal op de gevel.

Page 15: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad 4

3. PRINCIPE VAN DE BEREKENING ==========================

3.1 Algemeen

De geluidreductie, door een gevel voor een bepaalde geluidhron

buiten wordt aangegeven met het genormeerd

Dnr volgens:

(1

(geluiddruk)niveauverschil

T = L2m - Lo + 10 19 T (1)

o

waarbij:

L2 = het geluiddrukniveau in octaafbanden op 2m voor de gevel m.

(in het algemeen v~~r het meest belaste deel) ten gevolge

van de beschouwde geluidbron buiten, in dB t.o.v. 20~Pa

L het geluiddrukniveau in octaafbanden, ruimtelijk gemiddeld o

over het (ontvang)vertrek, in dB t.o.v. 20 ~Pa

T = nagalmtijd in octaafbanden in het vertrek,in 5

T = de referentienagalmtijd: 0,5 s, tenzij anders aangegeven. o

Noot: Voor vertrekken in woningen geldt altijd T = 0,5 s. o

Als voor andere typen vertrekken een andere referentienagalm-

tijd wordt aangehouden dient die expliciet te worden vermeld

en in het symbool te worden aangegeven, by. DnT=I'

Als het geluid b:Lnnendringt vta een, als vlak te be,schouwen, be­...

grenzingsvlak van het vertrek, ktln het genormeerd niveau-

. verschil D T worden berekend via: n .

V == R v lak + 10 19 6 + C

T S 1 kg. o v a

V~~r vertrekken in woningen met een referentienagalmtijd van

0, 5 sword t d it:

, D nT = Rv1ak + 10 Ig 1s . + C vlak g

(2a)

(2b)

Page 16: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad 5

De geluidisolatie van het samengestelde gevelvlak voIgt uit de geluidredQcerende.

eigenschappen van de samenstellende delen volgens:

S. R := - 10 19 (2

1

, _1_. -10 vlak Svlak

/10 -D ./10 ). +2 10 n,] +K Svlak

(3)

Hierinhebben de symbolen de volgende betekenis: . .

R vlak = geluidisolatie van het samengestelde gevelvlak In octaafbanden, in dB

S vlak

v c

g R.

1

DnJ

S. 1

A o

K

::: oppervlakte van het samengestelde gevelvlak, gezien vanuit het vertrek, . 2 In m

1 . h t t t k l'n m3 - vo ume van e on vangver re ,

gevelstructuurcorrectie, in dB

geluidisolatie van geveldeel i in octaafbanden, in dB

= op absorptie genormeerd niveauverschil (A := ') 0 m2) van ventilatie­

voorziening j in octa~fbanden, in dB1) 0

::: oppervlak~an geveldeel i, in m2

.= referentie-absorptie van 10 m2

kierfactor voor het in rekeningbrengen van geluidlekken via naden

en kieren in het gevelvlak.

Ais het geluid binnendringt via meerdere begrenzingsvlakken van het vertrek

kan voor elk begrenzingsv.lak apart een deel-niveauverschil D T . worden be­n ,1

rekend volgens de' formules 2 en 3.

<I

I)AIs de geluidreductie van een ventilatievoorziening is gegeven als geluid-

isolatie, gerelateerd aan een (eveneens gegeven) oppervlak, kan deze voor­

ziening ih principe ook opgelijke wij ze als een geveldeel in formule 3 in

rekening worden gebracht; zie ook bijlage C.2.S.

Page 17: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad 6

Het genormeerd niveauverschil voor de totale gevel (aIle begrenzings­

vlakken) moet worden gerelatee~d aan een buitenpositie. in het algemeen

die yoor het meest belaste begrenzingsvlak. aan te duiden als het referent ie­

vlak. Dit genormeerd niveauverschil voIgt uit de deel-niveauverschillen door

energetische sommatie, waarbij rekening wordt gehouden met mogelijke ver­

schillen tussen de geluiddrukniveau's buiten v~~r de begrenzingsvlakken:

(, - (D . . + ('~ .) / I 0 )

D = - 10 I g f- ) 0 nT, ~ -L~ nT ..... (4)

Hierin is:

D T • n ,1 genormeerd (geluiddruk)niveauverschil in octaafbanden als aIleen

geluidoverdracht via begrenzingsvlak i plaatsvindt;

i = het referentiebegrenzingsvlak waaraan het totale

genormeerd (geluiddruk)niveauverschil is gerelateerd.

eLi = correctie v~~r het verschil in geluiddrukniveau voor

Noot:

vlak i t.o.v. het referentievlak = L 2 f -L2 . , m,re m,1

In principe geldt voor elke octaafband een andere correctie VOOl'

het verschil in geluiddrukniveau buiten.

In veel gevallen wordt deze correctie ~hter beoaald door geo­

metrische factoren, zoals de zichthoek vanuit een begren­

zingsvlak en kan dan voor aIle octaafbanden hetzelfde

worden genomen.

In bijlage A wordt een rekenprogramma gegeven en beschreven,

waarmee volgens de hier gegeven formules het genormeerd

niveauverschil kan worden berekend.

Page 18: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad 7

3.2 Invoergegevens

3.2.1 geluidreducerende eigenschappen geveldelen en elementen, R en D -------------~-------------------------------------------------n

De geluidreducerende eigenschappen van de delen waaruit een gevel­

vlak (begrenzingsvlak) is opgebouwd worden in het algemeen aange-

geven met de geluidisolatie R van die delen.

In principe is deze geluidisolatie afhankelijk van het soort bron

en de orientatie ten opzichte van het gevelvlak.

III [3] is deze afhankelijkheid nader onderzocht, waaruit bleek dat

voor vrijwel aIle praktisch voorkomende situaties met redelijke

betrouwbaarheid als geluidisolatie v~~r geluid van buiten de ge­

luidisolatie v~~r diffuus invallend geluid kan worden gehanteerd,

d.w.z. de geluidisolatie zoals die in het laboratorium voor de

betreffende constructie kan worden bepaald uit:

S R = Lz - Lo + 10 Ig A (5)

Hiervan is:

R

L o

S

A

geluidisolatie in octaafbanden,in dB

het geluiddrukniveau in octaafbanden in het zendvertrek,in dB

= het geluiddrukniveau in octaafbanden in het ontvangvertrek,in dB

= oppervlakte van de scheidingsconstructie tussen zend- en

k . 2 ontvangvertre ,1n m 2 = absorptie in het ontvar:gvertrek in octaafbanden, in m •

De grootste, systematische, afwijkingen kunnen optreden bij puntbron­

nen onder grote hoeken van inval, b.v. 700 en groter. De afwijkingen

zijn echter zodanig afhankelijk van constructie en frequentie dat

geen eenduidige c:orrec tie i.s aan te geven.

Voor sommige gevelelementen is de geluidisolatie niet de meest hand­

zame grootheid ter karakterisering van de geluidreducerende eigenschap­

pen, namenliJk. die eleme.nten waarbiJ de geluidQverdracht niet eenduidig

met het oppervlak van het ~lement behoeft samen te hangen, zoals bij

ventilatievoorzieningen.

Page 19: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

3.2.2

blad 8

Voor lijke elementen wordt het niveauverschil voor diffuus , 2

iiwallend geluid gehanteerd met normering op 10 m absorptie in het

ontvangvertrek volgens: A

o Lz - Lo + 10 19 D

n A

hierin is:

D = het op absorptie gerlOrm~erd (geluiddruk)niveauverschi1. lon n

A

A o

:::

octaafbanden in dB

de absorptie

de referentie

2 in het ontvangvertrek in octaafbanden in m

absorptie van 10 m2 v~~r e1ke octaafband.

( 6)

In hoofdstuk 5 za1 nadere aandacht worden geschonken aan de meet­

methoden ter bepaling van de beide hier genoemde grootheden en de

moge1ijkheden, uit deze grootheden andere meetresultaten tot weg:

te leiden.

tructuurcorrectie CJ ----------------------0 De geluidisolatie van het samengestelde. gevelvlak volgens formule

(3) aan in welke mate gel~id dat buiten op d~t vlak,heerst

doordringt in het vertrek. Het aiveauverschil voor de gevel wordt

verdl'r bepaald door het verschi 1 tussen di t ge luiddrukni veau op het

gevelvlak en het geluiddrukniveau op 2m voor de totale gevel.

Dit'verschil is afhankclijk van de vormgeving en profilering van

degevel, de gevelstructuur. Dit verschil wordt verdisconteerd door

de gevelstructuurcorrectie C , gedefinieerd volgens: g

Cg ::: L2m - Lop

gevelvlak

(7)

L2m ::: het geluiddrukniveau in octaafbanden,in dB,op2m voor de

gevel, zoals omschreven bij de meetmethode ( 1 ]

L op

gevelvlak

het geluiddrukniveau in octaafbanden,_ in dB, zoals dat

gemiddeld op het gevelvlak heerst.

Page 20: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad 9

Voor een ideaal vlakke gevel is het geluiddrukniveau op 2m afstand

3dB hoger. en het geluiddrukniveau op het gevelvlak 6 dB hoger dan

het geluiddrukniveau van het invallende geluid (het geluiddrukniveau

dat ter plaatse van de gevel zou heersen zonder aanwezi~heid van die

gevel), waarmee de gevelstructuurcorrectie 0 dB wordt.

Bij andere gevelvormen zal deze correctie in principe afwijken van

o dB. Bij balkons en galedjen kan enerzijd.s geluidafscherming

plaatsvinden, waardoor het geluiddrukniveau op het gevelvlak afneemt,

terwijl tevens tegen galerijen extra geluidreflecties kunrien optre­

den of door de beslotenheid van een balkon een galmveld kan ont­

staan. Daarmee neemt het geluiddrukniveau op het gevelvlak weer toe.

De gevelstructuurcorrectie kan hierdoor zowel positief als negatief

w~rden [ 4 ] •

Bij hellende vlakken -daken, terraswoningen- zal naar het meetpunt

op 2m van het vlak geen geluidreflectie van het vlak optreden, ter­

wijl op het vlak zelf ook dan drukverdubbeling zal optreden. De gevel­

structuurcorrectie wordt in dat geval-3 dR.

V~~r verschillende gevelstructuren is in bijlage B eenoverzicht ge­

gevenvan toe te pass en gevelstructuurcorrecties.

3.2.3 kierfactor K ------------Voor de berekening van de geluidreductie van gevels zijn de geluid­

lekken via naden en kieren van groot belang. Voldoende is bekend

over de geluidoverdrach~ van goed gedefinieerde openingen en spleten.

In [5] is op basis van de theorie de geluidisolatie van spleten ~

nader u.itgewerkt voor toepassing bij de geluidreductie door gevels·

. voor wegverkeergeluid. Een praktisch probleem bij de toepassing

van dergelijke gegevens is, dat de afmetingen (lengte, diepte en

breedte) van naden en spleten bij een gevel sterk kunnen varieren

en feitelijk nauwelijks wed zijn te bepalen.

Page 21: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad 10

Deze geluidlekken blijven daardoor een onzekere factor in de geluid­

reductie-berekeningen.

Teneinde het in rekening brengen van kieren en naden toch hanteerbaar

te maken ~s een aantal categorieen gevels onderscheiden waarvoor

een bepaalde kierfactor K van toepassing is. Deze kierfactor is af­

geleid uit de deeltermen in formule 3:

Sk' K = ~ 10

S gevel

-Rk

. / I 0 ~er (8)

Op basis van mogelijke indelingen van gevels is globaal aan te nemen

'dat Sk' / S 1 ongeveer constant is, terwij 1 op basis van de theorie[5,15J ~er geve

voor een aantal typen kieren.de kierisolatie R. is te bepalen. k~er

Combinatie van deze gegevens levert voor diverse typen gevels een kier-

factor.

Een overzicht vandeze kierfactoren met beschrijving van de bijbe­

horende geveltypen is gegeven in bijlage B.

Een gevel vervult veelal ook een ventilatie-functie via te openen

delen of speciale ventilatievoorzieningen. In die gevallen zal het

te berekenen genormeerd niveauverschil be trekking moeten hebben

op een zodanig geventileerde gevel dat aan de gestelde ventilatie­

eisen wotdt voldaan. Dergelijke eisen z~Jn in principe gesteld in

een minimale luchthoeveelheid in m3/s onder genormeerde omstandigheden.

Onder voorwaarden is deze eis te interpreteren als een minimaal ver­

eiste opening in m2

( 6 ] •

In bijlage C zijn enkele indicati8ve gegevens opgenomen ten aanzien

van het op 10 m2 absorptie genormeerd niveauverschil van ven­

tilatievoorzieningen bij een luchtdoorlaat van 10-3 m3/s, waarbij

-3 2 als ongedempte voorziening uit isgegaan van een opening van 10 m.

Deze gegevens kunnen in de berekening worden gehanteerd met aanpas­

sing aan de feitelijk vereiste luchthoeveelheid • . ',

Page 22: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad 11

In 'grote lijnen komt de ventilatie-eis neer 'op een luchthoeveelheid

in 10-3 m3/s die in getalwaarde gelijk is aan het vloeroppervlak van

het vertrek in m2• Met name in bestaande situaties zal het echter

veelal praktisch ondoenlijk zijn deze eis volledig met geluidgedempte

ventilatievoorzieningen te realiseren.

3.3 Stylering van gevel en vertrek

Voor de berekening wordt een gevel opgebouwd gedacht uit een of meer

platte Ctwee-dimensionale) begrenzingsvlakken van het vertrek , de eigenlijke gevelvlakken, al dan niet'voorzien van een verdere uit­

wendige constructie zoals een balkon.

Een begrenzingsvlak kan als plat worden beschouwd als de afstand

tussen het binnenste en het meest naar buiten gelegen deel niet

groter is dan 0,4 m.

Uitbouwen, erkers en dergelijke worden dan in het platte vlak gedacht

met als oppervlakte de werkelijke oppervlakten van deze uitstekende

d~len zoals vanuit het vertrek gezien.

Indien volgens deze regelniet meer van een plat vlak kan worden ge­

sproken dan is een verdere opdeling van de gevel in begrenzingsvlakken

noodzakelijk waarbij als basis v~~r deze indeling de geluiddrukniveaus

voor de dan te onderscheiden delen van de gevel dient.

Elk deel van de gevel waarvoor het geluiddrukniveau min of meer con­

stant mag worden verondersteld wordt dan alsbegrenzingsvlak beschouwd.

Dit begrenzingsvlak behoeft dan niet plat te zijn in de hiervoor aan­

gegeven betekenis. Als oppervlakte van de samenstellende delen van

elk begrenzingsvlak wordt wederom het werkelijke oppervlak aangehouden,

gezien vanuit het vertrek.

Buitenbegrenzingen van het vertrek waarop vanaf de bron geen zicht

mogelijk is kunnen meestal buiten beschouwing worden gelaten. Dit betreft

bijvoorbeeld zijvlakken, daken of onderdelen van een erker.

Page 23: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad '12

De verschillen in geluiddrukniveau voor de te onderscheiden begrenzings­

vlakken zullen veelal door geometrische factoren (orientatie van vlak

en bron) worden bepaald. Voor een aantal veel voorkomende situaties

is in bijlage Been overzicht gegeven van de toe te passen buitenniveau­

correctie CL

In veel situaties zal het effectieve volume vanhet vertrek overeen­

komen met het feitelijke volume, waarvan de bepaling geen probleem is.

Bij afwijkende vertrekvormen, zoals bij open keukens of Z-kamers,

zal niet het ~ele volume effectiei als zodanig werken. Zeker alB in

getalwaarde het totale volume groter is dan ca. 9 keer het totale op­

pervlak van de gevelvlakken, moet met een kleiner effectief volume

worden gerekend dan het feitelijke volume. In die situaties kan worden

gerekend met het volume dat behoort bij de grootst mogelijke rechthoek

met het gevelvlak als zijde, die nog in de plattegrond van het ver­

trek past. Bij meerdere gevelvlakken (begreniingBvlakken,) kan op die

wijze per gevelvlak een rechthoek worden gevonden, waarbij de omhul­

lende van deze rechthoeken bepalend is voor het in rekening te bren­

gen volume.

Page 24: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad 13

4. GEBRUIK BIJ SPECIFIEKE GELUIDBROHNEN ================================~===

4. I Gebruik bij wegverkeer

De principes van ,de berekeningsmethode, zoals in hoofdstuk 3 gegeven,

zijn zonder meer van toepassing op de berekening van de geluidreductie

door gevels voor wegverkeersgeluid. De berekening kan daarbij betrek­

king hebben op het totale aanwezige verkeersgeluid dan weI op een be­

paalde verkeersstroom, ,door optoepasselijke wijze voor de betreffende

situatie het verschil in geluiddrukniveau voor de te onderscheiden

begrenzingsvlakken in rekening te brengen.

In praktisch voorkomende situatiea is het gebruik van isolatiegegevens

voor diffuus geluid voldoende nauwkeurig.

Ret verschil in geluiddrukniveau voor verschillende begrenzingsvlakken

wordt door,de geometrische factoren voldoende nauwkeurig bepaald, zo-

als in bijlage B is aangegeven, tenzij geen van de begrenzingsvlakken

direct zicht heeft op de verkeersstroom of -stromen.

Delen van de gevel waarop vanaf de verkeersstroom geen direct zicht

mogelijk is kunnen buiten beschouwing worden gelaten. Als criteria

geldt hierbij de zichtIijn vanaf de denkbeeidige as van de bron,

tenzij vanaf de verst van de gevel afliggende verkeersstroom de

zichtlijn hiervan meer'dan 100 afwijkt, in welk geval deze laatste

zichtlijh als criterium geldt.

4.2 Gebruik bij railverkeer

De principes van de berekeningsmethode, zoals in hoofdstuk 3 gegeven,

zijn zonder meer van toepassing op de berekening van de geluidreductie

door gevels voor railverkeersgeluid.

De nadere aanwijzigingen omtrent het gebruik zijn volledig overeen­

komstig het gestelde ten aanzien van wegverkeersgeluid in paragraaf 4.1.

Page 25: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad 14

4.3 Gebruik bij luchtverkeer

De principes van de berekeningsmethode, zoals in hoofdstuk 3 aan­

gegeven, zijn zonder meer van toepassing op de berekening van de

geluidreductie door gevels voor luchtverkeersgeluid.

In navolging van de definitie bij andere soorten geluidbronnen wordt

hierbij de geluidreductie gedefinieerd als het genormeerd geluid­

niveauverschil ten opzichte van een meetpunt buiten bp 2m voor de

gevel. In geval van meerdere begrenzingsvlakken wordt in dit geval, 'gezien

de niet eenduidige situatie ten aanzien van de mate van belasting

van de verschillende vlakken, het referentiepunt gekozen voor het

vertikale begrenzingsvlak met de (aan te nemen) geringste geluid­

reductie of -bij afwezigheid van vertikale begrenzingsvlakken- in

het verlengde van een vertikaal gevelvlak ter hoogte van het dakvlak.

Bij meerdere begrenzingsvlakken van een vertrek worden in principe

al deze begrenzingsvlakken in de berekeningen opgenomen, waarbij

het geluiddrukniveau buiten voor deze vlakken gelijk wordt genomen.

Alleen wanneer onder aile omstandigheden de vliegtuigbewegingen zodanig

zijn dat vanuit de bron geen zicht mogelijk is op een bepaald be­

grenzingsvlak mag dat vlak buiten beschouwing worden gelaten.

Page 26: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad 15

4.4 Gebruik bij overige geluidbronnen

De principes van de berekeningsmethode, zoals in hoofdstuk 3 gegeven,

zijn ook van toepassing op de berekening van de geluidreductie door

gevels voor andere bronnen van buitengeluid dan weg-, rail- of

lucht;:verkeer. Te denken valt aan industrieen, recreatie -inrichtingen

en dergelijke.

In veel gevallen zullen hierbij bronafmetingen en orientatie ten opzichte I

van de gevel zodanig zijn dat geen wezenlijk onderscheid bestaat met

wegverkeer. De aanwijzigen ten aanzien van het gebruik in hoofdstuk 4

zijn dan eveneens van toepassing.

Uitzonderingen zullen met name worden gevormd door br onn en die zich

bevinden binnen een beperkte openingshoek vanuit de gevel onder een

grote hoek met de normaal op die gevel.

De feitelijke geluidisolatie van de geveldelen kan in die situatie

niet onaanzienlijk afwijken van die v~~r diffuus invallend geluid.

De afwijkingen kunnen echter zowel positief als negatief zijn, af­

hankelijk van het type constructie en de frequentie. Enige indicaties

ten aanzien van dit punt v~~r een aantal typen constructies zjjn te

viriden in [ 3 ] • Dergelijke afwijkingen zijn echter niet eenvoudig

in rekening te brengen, terwijl anderzijds de geluidisolatie onder

dergelijke hoeken van inval doorgaans niet bekend is.

Daarnaast is onder min of meer scherende inval langs de gevel de

invloed van de structuur daarvanvan relatief grotere invloed.

Een en ander beperkt de mogelijkheid tot betrouwbare berekeningen

in dergelijke situaties.

Vooralsnog lijkt het niet waarschijnlijk dat een andere aanpak van

de berekeningen dan volgens de principes uit hoofdstuk 3 met de

isolatiegegevens v~~r diffuus geluid tot wezenlijk betere voorspel­

lingen zal leiden.

Page 27: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

brad 16

5. GELUIDISOLATIEGEGEVENS ======================

5.1 'Karakteristieke gegevens

De nauwkeurigheid van de berekening van de geluidreductie door gevels

wordt in eerste instantie bepaald door de nauwkeurigheid van de in­

voergegevens, met name de geluidisolatie van geveldelen en het ge­

normeerd niveauverschil v~~r gevelelementen. Van veel bij gevels

toegepaste constructies zijn meetgegevens beschikbaar. De resultaten

varieeren echter veelal vrij sterk, ook bij ogenschijnlijk identieke

constructies. Enerzijds is dat een van constructieeigenschappen,

zoals afmetingen en randinklemming, anderzijds is ook de laboratorium­

situatie, de inbouwwijze en meetmethodevan invloed.

In het kader van ICG-onderzoek VL 12 is een literatuurstudie verricht

om v~~r verschillende typen gevelconstructies de geluidisolatie in

octaafbanden te kunnen aangeven [ 9,10 ] • Behalve het verzamelen en

rangschikken van meetgegevens waarmee deze v~~r gebruik hanteerbaar

zijngemaakt is op deze manier ook eeh consistent geheel verkregen, ,

waarbij uit de soms sterk uiteenlopende meetgegevens zo goed mogelijk

de karakteristieke tendensen in de geluidisolatie van de verschillende

typen constructies naar voren komen.

Ter vereenvoudiging van de toepassing van deze gegevens in het computer­

rekenmodel v~~r de geluidreductie door gevels, zijn deie karakteristieke

isolatiegegevens ook in fbrmule-vorm omgezet, waarbij op een aantal

punten de consistentie in het geheel nog kon worden versterkt.

Dit wordt nader besproken in bijlage C.

In eerste instantie wordt aanbevolen bij de berekening deze karakte-

ristieke geluid

berekenen van wijz

invloed van toeval

te vermijden.

toe te passen, met name ook om bij het

en verbeteringen in de gevelconstructie de

en systematische afwijkingen in meetgegevens

Page 28: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad 17

Voor sommige typen gevelconstructies zijn echter slechts weinig of

in het geheel geen (karakteristieke) gegevena bekend,zodat van

andere meetgegevens gebruik moet worden gemaakt.

5.2 Gebruik meetgegevens

Meetgegevens van geveldelen of -elementen moe ten zomogelijk betrek­

ling hebben op laboratoriummetingen met diffuus geluid aan zend- en

ontvangkant, bepaaldvolgens ISO 140 [ 11 ] of daaraan gelijkwaar­

dige meetvoorschrifteno

+ 10 S

(8a) R = L - L 19 -z 0 A

A D L - L + 10 19

0 C8b) = n Z 0 A

Als dergelijke gegevens niet beschikbaar zijn kan als redelijke ben a­

dering eventueel ook gebruikworden gemaakt van gegevens met geluid­

inval onder eenhoek v met de normaal op het geveldeel

R = L _ L + 10 19 48 cos v u invallend 0 A (Sc)

De beste benadering wordt verkregen met een hoek van inval tussen o 0 - ] a 45 en 60 [3 , welke uit een meetresultaat bij 45 kan worden afge-

leid door dit met 1,5 dB te verminderen.

Noot 1: Hetzelfde resultaat wordt verkregen als bij geluidinval onder

een hoek van 450 het dee1 "4 cos 45°" uit de normeringsterm

van formu1e Se: wordt weggelaten en vo'or de zendzijde niet het

geluiddrukniveau van het inval1ende geluid wordt gehanteerd

maar het geluiddrukniveau zoals dat op 2 m voor de constructie

heerst (formu1e 9).

Noat 2: Voor sommige constructies, zoa1s hoY. dakconstructies, ken een

rea1istische opbouw in laboratoriummeetruimten praktische be­

z waren hebben 0

In die gevallen,kunnen onder voorwaarden praktijkmeetresul­

taten worden gehanteerd, waarbij de geluidisolatie wordt

bepaa1dvolgens [l,llJ :

Page 29: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

R S

L - L + 10 19 -2m 0 A

blad18

( 9)

De geluidbron kan hierbij een aanwezige bron zijn of een

kunstmatige geluidbron met geluidinval onder een hoek van

ca. 45 0,

Bij de toepassing van dergelijke meetgegevens moet getracht worden de

gegevens te gebruiken van de constructie die zo goed mogelijk overeen-

komt met de feitelijk te constructie. Ret verdient aanbeveling

dergelijke meetgegevens te vergelijken met de karakteristieke isolatie­

gegevens van min of meer gelijksoortige constructies teneinde indicaties

te verkrijgen over mogelijke systematische afwijkingen tengevolge van

de meetsituatie of meetmethode.

Ten aanzien van ventilatievoorzieningen worden bij (laboratorium-)

metingen in de literatuur en in fabrikanteninformatie nog verschil­

lende andere methoden aangehouden om de geluidreducerende eigenschap­

pen aan te geven, dan het hier gehanteerde op 10 m? absorptie genor­

meerd niveauverschil. Als voldoende gegevens -bekend zijn over

het type fisolatiegegeven' kunnen dergelijke gegevens eenvoudig worden

herleid.

In bijlage C is dat nader aangegeven.

Page 30: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad 19

6. TOEPASSING REKENRESULTATEN ========~=================

6.1 Een-getals aanduiding

De geluidreductie van de gevel wordt aangegeven door ~et berekende genor­

meerd niveauverschilDnT in octaafbanden.

Dit resultaat kan worden uitgedrukt in een getal op een of meer van de

volgende wijzen:

- het genormeerd gevelverschil in geluidniveau-A voor een gegeven

(referentie)spectrum, D· T A f n , re •

Deze grootheid wordt verkregen door per octaafband het A-gewogen

referentiespectrum te verminderen met het berekende genormeerd niveau­

verschil DnT en het geluidniveau-A van het resulterende spectrum of te

trekken van het geluidniveau-A van het referentiespect~um; zie bijlage D.

Het resultaat wordt afgerond op hele dB's waarbij 0,5 dB wordt afgerond

naar het dichtstbijzijnde gehele even getal.

Als het standaard-referentiespectrum voor wegverkeer, railverkeer-

of luchtverkeersgeluid wordt gehanteerd, wordt het resultaat aangegeven

als resp. D D of D nT,Av' nT,Ar nT,Al'

- het gewogen genGJrmeerd niveauverschil D nT,w

Deze grootheid wordt verkregen door op het rekenresultaat de weegproce­

dure volgens ISO/DIS 717 [7J te hanteren, toegepast op octaafbanden t.

- de gevelgeluidreductie-index I ge

Deze grootheid wordt verkregen door op het rekenresultaat de weeg­

procedure volgens NEN 1070 [8J toe te passen.

Een dergelijke een-getals aanduiding kan dienen om het berekeningsresultaat

te vergelijken met gestelde eisen ten aanzien van de geluidreductie in

termen van diezelfde een-getals grootheid.

Page 31: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad 20

6.2 Geluidniveau binnen

Aan de hand van de berekende geluidreductie van de gevel kan op

basis van een gemeten of berekend geluiddrukniveau buiten voor het

referentievlak, het geluid(druk)niveau in het vertrek worden be­

rekend.

L = L o 2m,ref (0)

Als het geluiddrukniveau ter plaatse van het referentiepunt uit

metingen of. berekeningen bekend is zonder aanwezigheid van de

gevel <invallend geluid) dan geldt:

L = L. + C 2m,ref 1nvallend r ( 11)

De correctie VQor de gevelreflectie C varieert tussen 0 en + 3 dB, r

afhankelijk van de ~evelstructuur.

Bij vlakke gevels is de waarde + 3 dB, v~~r diverse geyelstructuren

is een overzicht gegeven van deze correctie in bijlage B.

In' het algemeen betreffen de formules en grootheden de octaafbanden.

Deze formules zijn echter Qok op A-gewogen grootheden toe te passen als

het geluidniveau buiten en het gevelverschil:in geluidniveau-A peide betrek-

king hebben op hetzelfde referentiespectrum.

Delft, 2:6 Juni 1~81

Ge/TW

Technisch Physische Dienst

ire Gerretsen

Page 32: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad 21

Literatuur

[ 1J ir. E. Gerretsen, "Geluidreductie door gevels v~~r wegverkeers­

geluid .... meetmethoderl', ICG-publikatie WG-HR-05-01, augustus 1981

[ 2J brochure "Verkeerslawaai en woningen", Bouwcentrum, maart 1981

[ 3] ir. E. Gerretsen, "Meetmethoden'voor de Geluidreductie door

gevels - voorstudie", TPD-rapport 907.794, 5 februari 1980

[ 4J ir. E. Gerretsen, "Meetmethoden voor degeluidreductie door

gevels - nader onderzoek t.b.v. enkele facetten van de

meetmethoden", TPD-rapport 007.794, oktober 1979

[ 5] ir. M.G. Gomperts, "Handleiding v~~r het berekenen van gevel­

isolaties tegen wegverkeerslawaai", ICG-publikatie

VL- DR-12-01, oktober 1979

[ 6J NEN 1087 "Ventilatie in woongebouwen -eisen", Ie druk, december 1975

NPR 1088 "Ventilatie in woongebouwen, aanwijzingen voor en voor­

beelden van constructieve uitvoering van ventilatievoorzi.eningen",

Ie druk, november 1975

[ 7] ISO/DIS 717, "Rating of sound isolation in buildings and of

buildings elements, Part I, II, III, 1980

[ 8] NEN 1070, "Geluidwering in woongebouwen", 2e druk, september 1976

[ 9] ir. P. van Doorn-IJzerman, "Literatuur cmder.zoek, naar de lucht­

geluidisolatie van verschillende gevelmaterialen ten behoeve van

de berekening ..,an gevelisolaties", I Glas', II Muren en borstwe­

ringen, IMG-rapporten B 427, juli 1980 en B 431, juli 1980

Page 33: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad 22

[10] ir. P. van Doorn-IJzerman, drs. J. P. Kaper,

"Literatuuronderzoek naar de geluidisolatie van verschillende

gevelmaterialen ten behoeve vande berekening van gevelisolaties

-samenvattend rapport", ICG - publikatie VL-HR-12-~2, 1981

[11] ISO 140, "Measurement of sound insulation in buildings and of

building elements, Part III. Laboratory measurements of airborne

sound insulation of building elements", 1978-07-15; Part V

Field measurements of aLrborne sound insulation of facade

elements and faca:des", 1978-07-15.

[12] ir. F. Kranendonk/F .S. Ophof, "Voortgezet onderzoek naar de

geluidisolatie van, vlakglas", TPD-rapport 2220, 15 januari 1979

[13] E.T. Weston/M.A. Burgess/ B.A. Whitlock "Airborne sound trans­

mission through elements of· buildings", Technical study.no. 48,

Department of Housing and Construction, Experimental Building

Station, Canberra, Australie, 1973

[1LJ K.R. Cook, "Sound insulation of domestic roofing systems:

Part I, II and III", Applied Acoustics 13(1980), 109-120,

203-210, 313-329.

[ ] M. G. Gomperts, T. Kihlman, "The sound transmission loss

of circular and slit-shaped apertures in walls", Acustica 18

(1967), 144

[ 16] ire E. Gerretsen, "Vergelijking met meetresultaten van drie

verschillende uitwerkingen van een rekenmethode voor de gevel­

geluidreductie", lPD-rapport 007.794/2,

3 oktober 1980

[17J ir. E. Gerretsen. ir.' F. Kranendonk. "Geluidreductie van een aantal

ventilatievoorzieningen", TPD-rapport 2222, februari 1981.

Page 34: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

BIJLAGE A: Computer-rekenprogramma VQor de geluidreductie

door geve1s.

A.I Beschrijving programma-gebruik

Ret computerprogramma op basis van het in deze publikatie beschre­

ven rekenmodel is geschreven in BASIC-V.

De gegevensinvoer en resu1tatenuitvoer vindt plaats via een

beeldscherm met de mogelijkheid van getypte uitvoer van deze

gegevens.

De benodigde invoergegevens zijn:

- referentiespectrum; gestandaardiseerde referentiespectra v~~r

weg-, rail- en luchtverkeer zijn in het programma opgenomen

- projectnaam

- volume van het vertrek

- aantal gevelbegrenzingsvlakkenj de berekening wordt voor elk

begrenzingsvlak apart uitgevoerd, waarna eveneens het totaal

resultaat wordt berekend

verder per begrenzingsv1ak:

- buitenniveaucorrectie (a1s er meer begrenzingsvlakken zijn)

- opperv1akte

geve1structuurcorrectie

- specifiek kiertype of kierfactor (frequentie-onafhankelijk); de be­

rekeningen worden behalve voor dit kiertype altijd uitgevoerd voor

type 0 (K=O) , type 1 (K=10-4) en type 3 (K=10-3 , diepe kier).

- aanta1 geveldelen

verder per geveldee1:

opperv1akte

- ge1uidiso1atie of genormeerd~iveauverschil. Voor een

aantal constructietypen zijn karakteristieke gegevens in het

programma opgenomen en kan worden volstaan met het aangeven

van het type en afmetingen en dergelijke. Bij ventilatievoor­

zieningen moet in dit geval ook de vereiste luchthoeveelheid,

waaraan de voorziening moet voldoen, worden opgegeven.

Page 35: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

·blad A2

De uitvoer per begrenzingsvlak bestaat uit:

de invoergegevens inclusief de isolaties in octaafbanden volgens

de gebruikte karakteristieke gegevens. Deze isolatie wordt ook

gegeven 'na A-weging volgens het opgegeven referentiesspectrum

Hierbij worden de volgende afkortingen toegepast voor het aan­

duiden van constructietypen:

GLAS-E 6 mm

GLAS-L 8 mm

GLAS-D 6 12 8

GLS-DG 6 12 8

STN-EN 400 KG/M2

SIN-SP 380 KG/M2

BRSTWG TYPE 3

:enkel glas met dikte Ln mm

:gelamineerd glas met constructiedikte in mm

:dubbel glas met opbouw (glas/spouw/glas) Ln mm

:dubbel glas met gasvulling en opbouw in mm

:steenachtige enkelvoudige constructie met massa in kg/m2

: steenachtigespouwconstructie met totale massa in kg/m2

:lichte samengestelde borstweringmet type-aanduiding

(tabel el)

DAK TYPE 2 :samengestelde dakconstructie met type-aanduiding(tabel C2)

VENTIL TP 3 12M.M .... 3/s :ventilatievoorziening met type-aanduiding en luchthoeveel-

h . d . 0-3 3/ .. . . eL Ln 1 m s; het hLerbLJ aangegeven oppervlak LS ge-

baseerd op indicatieve afmetingen (tabel e3)

R/oeT ':ingevoerde geluidisolatie per octaafband

R/oeT :ingevoerd genormeerd niveauverschil per octaafband

- de geluidisolatie van het samengestelde vlak

- het genormeerd (geluiddruk)niveauverschil bij kiertypen 0,1,3

en vol gens het ingevoerde specifiekekiertype

Deze worden gegeven in octaafbanden en in de volgende een-getals­

aanduidingen

- gevelisolatie-index I volgens NEN 1070 (IGE) ge

- gewogen niveauverschil D T volgens ISO/DIS 717 met tUBsen haken de maximal€. n w, onderschreidingalsdeze in een octaafband groter is dan 5 dB (DNTW)

- gevelverschil in geluidniveau-A voor het referentiespectrum (DNTAR)

Deze laatste berekeningsresultaten worden ook gegeven v~~r de totale

gevel.(alle begrenzingsvlakken gezamenlijk).

Een voorbeeld van de in- en uitvoer (getypte uitvoer, welke vrijwel

identiek is aan de uitvoer op het beeldscherm) is gegeven bij het·

rekenvoorbeeld in bijlage E.

Bij berekening met een begrenzingsvlak kurnen een of meer gevel­

delen gewijzigd worden v~~r een nieuwe qerekening.

Page 36: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad A3

A.2 Programmabeschrijving

Het programma als voIgt opgebouwd (zie volledige programma-

tekst op de b~aden A 6 tim A 14)

regel 1 - 40

Programmatitel, dimensionering grootheden, definitie uitvoer­

bestanden

regel 45 - 110

gegevens betreffende enkele spectra, isolatie constructies,

kierfactoren, normwaarden en dergelijke

regel 115 - 144

bepaling referentiespectrum

regel 145 - 220

algemene gegevens invoer

gegevens per geveldeei via subroutine 1000

regel 225 - 320·

berekening isolatievan het samengestelde vlak

regel 330 - 466

uitvoer op beeldscherm met berekerting DnT

; een-getalsaanduidingen

worden berekend via subroutine 2000

uit~oerbestand wordt beschreven ·via subroutine 8000 (per begren­

zingsvlak) en subroutine 8500 (totaal resultaat bij meerdere

begrenzingsvlakken)

regel 468 - 600

uittypen van uitvoerbestand via subroutine 9000

wijzigen gevelconstructie(s) via subroutine 1000

.starten nieuwe berekening of beeind berekeningen

Page 37: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

regel 800 - 840

foutmeldingen

Subroutine 1000; regel 1000 - 1990

regel 1000 - 1035

oppervlakte en type per geveldeel

regel 1040 - 1090 ~

invoer geluidisolatie of op 10m2 absorptie genormeerd niveau­

verschil

regel 1100 - 1190

karakteristieke geluidisolatie enkel glas

regel 1200 - 1290

karakteristieke geluidisolatie gelamineerd glas

regel 1300 - 1399

karakteristieke geluidisolatie dubbel glas met luchtvulling

regel 1400 - 1499

karakteristieke geluidiso~atie dubbel glas met gasvulling

regel 1500 - 1590

karakteristieke geluidisolatie steenachtige constructies

regel 1600 - 1690

karakteristieke geluidisolatie lichte borstweringen

regel 1700 - 1790

karakteristieke genormeerd~luidniveauverschil ventilatie­

voorzieningen

Page 38: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad AS

regel 1800 - 1890

karakteristieke geluidisolatie dakconstructies

regel 1900 - 1990

A-weging volgens het referentiespectrum van octaafbandgegevens

volgens deze subroutine

Subroutine 2000; regel 2000 - 3500

regel 2000 - 2420

berekening gevelisolatie-ihdex uit DnT in octaafbanden

regel 2500 - 2510

berekening gevelverschil in geluidniveau-A voor het referentie­

spectrum

regel 3000 - 3500

berekening gewogen geluidniveauverschil uit DnT in octaafbanden

Subroutine 8000; regel 8000 - 8490

invullen uitvoerbestand met invoergegevens en rekenresultaten

voor een begrenzingsvlak

subroutine 8500; regel 8500 - 8990

invullen uitvoerbestand met rekenresultaten voor de totale gevel bij

meerdere begrenzingsvlakken

subroutine 9000; regel 9000 - 9100

vullen van het uit te typen bestand met het uitvoerbestand

Page 39: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

1 2 3 4 5 6 7 8 9

10 11 12 13 14 15 16 17 18 19

·20 21 22 23 24 25 26 P 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42, : 43 44 45 46 4,7 48 49 50 51 52 53 54 55

brad A6

1 PRINT "******** TECHNISCH PHY8I8CHE DIENST·TNO-TH DELFT ******** II

2 PRINT " •. II

3 PRINT "------------:-----BEREKENING GELUIDREDUCTIE---------------- " 4 PRINT "----------:----SAMENGE8TELDE GEVELS INCLUSIEF------------:--- " 5 PRINT "------------KARAKTERI8TIEKE MATERIAALGEGEVEN8------------ II

6 PRINT " " 7 PRINT n******** VERSIE: 81-02-11 ******* AUTEUR: EG ******** " 8 PRINT " " 9 PRINT" TENZIJ ANDER8 AANGEGEVEN KUNNEN NIET-NUMERIEKE II

10 PRINT II VRAGEN MET HET RELEVANTE WOORD, MAAR MINSTENS " 11 PRINT " DE EER8TE LETTER DAARV AN WORDEN BEANTWOORD " 12 PRINT " " 15 SLEEP 30 20 DIM RT(10,10),DT(9,12) 25 MAT RT=ZER:MAT DT=ZER 30 OPSCH1$=" FREQ(HZ) IN; INft; Inft; Inl1! IIlttNI lf1nN!" 31 OPSCHll$=" 11111111" 32 OP8CH2$=" IGE,DNTW,DNTAR 1111/; 11111/(\ \) 111;11" 40 AS 1116="Bl":OPEN 11l6:AS 1126="B2":OPEN 1126 45 ON ERROR GOTO 800 46 REM . 1+7 REM REFERENTIESPECTRA/KIERFACTOREN/ENKELE MATERIAALGEGEVENS 48 REM 49 RESTORE 50 DATA DUM, 63 , 125.,250,500, 1000,2000,4000 . 51 DATA WEGVERKEER,-26,-14,-10,-6,-4.5,-7,-14 52 DATA RAILVERKEER -31 -27 -17 -9 -4 -4 -12 , , , ','" 53 DATA LUCHTVERKEER,-33,-21,-11,-7,-4.5,-6,-12 60 DATA "KTYPE 0",0,0,0,0,0,0,0 61 DATA "KTYPE 1",0.4,0.2,0.1,0.06,0.04,0.13,0.13 62 DATA "KTYPE 3",4,2,1,0.6,0.5,3.2,1.6 63 DATA "KTYPE 4",8,4,2,1.3,0.8,0.6,2.5 64 DATA "KTYPE 2",1.6,0.8,0.4,0.25,0.16,0.5,0.5 65 DATA "KTYPE 7",40,20,10,6~4,13,13 66 DATA "KTYPE 5",10,5,2.5,1.6,1.3,8,4-67 DATA "KTYPE 6",20,10,5,3.2,2,1.6,6. 70 DATA BWl,10,15,20,25,30,30,35 71 DATA BW2,15,20,25,30,30,35,40 72 DATA BW3,15,22,30,35,40,40,45 73 DATA BW4,20,25,35,40,45,50,55 74 DATA BW5,20,30,40,48,55,60,65 80 DATA 881,40,40,40,40,40,40,40 81 DATA 8S2,37,37,37,37,37,38,39 82 DATA 883,40,36,33,36;45,55,65 83 DATA S84,40,37,38,43,51,59,65 84 DATA 8S5,40,40,44,51,58,65,65 90 DATA DKl, 10, 10;11 ,12,1.3,14,15 91 DATA DK2,15,20,22,25,28,28,28 92 DATA DK3,15,20,25,30,35,35,35 93 DATA DK4,15,20,30,35,45,50,55 94 ~ATA DK5,20,25,30,35,40,45,50 95 DATA DK6,20,25,40,47,55,60,65 96 DATA DK7,30,35,45,50,55,60,65 100 N(3)=34:N(4)=43:N(5)~50:N(6)=53:N(7)=54

.110 READ T$:FOR J~2 TO 8:READ RT(O~J):DT(O,J)=RT(O,J):NEXT J

Page 40: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79

. 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99

100 101 102 103 104 105 106 107 108 109 110

blad A 7

. . 115 PRINT ItSTANDAARD WEG-,RAIL-,LUCHTVERKEER OF ANDER REFERENTIESPECTRUM" 120 INPUT S$ 125 IF LEFT(S$,l%)="W" OR LEFT(S$,l%)="R" OR LEFT(S$,l%)= tlL" GOTO 135 127 INPUT "NAAM ANDER SPECTRUMtI

, T$ 130 PRINT "A-GEWOGEN SPECTRUM(63-4000HZ/0 DB(A»tI 132 FOR J=2 TO 8:PRINT USING n¥tlI1fII: n,RT(0,J);:INPUT V(J):NEXT J 134 GOTO 139 . 135 REPEAT 136' READ T$ :FOR J=2 TO 8 : READ V(J) :NEXT J 137 UNTIL LEFT(T$,1%)=LEFT(S$,1%) 139 S$=T$:PRINT:PRINT S$ 140 FOR L=O TO 2. 141 READ T$:FOR J=2 TO 8:READ K(L,J):K(L,J)=K(L,J)/1000:NEXT J 142 IF LEFT (T$, l%»(tlKtI GOTO 141 143 KTYP$(L)=MID(T$,2%,6%) 144 NEXT L:RESTORE 145 REM 146 REM SITUATIE-INVOER

"GEVELBEREKENING":PRINT 147 REM 150 PRINT 155 INPUT 160 INPUT 165 INPUT 166 PRINT

"PROJECT NAAM ",PROJ$ "VOLUME VAN'T VERTREK "VOL , .

'·'AANTAL GEVELVLAKKEN ",NVLAK

167 JVLAK=O:JVLAK$="":IF. NVLAK=1 GOTO 175 169 FOR L=O TO 3:FOR J=2 TO 8:DT(L+6,J)=0:NEXT J:NEXT L 170 JVLAK=JVLAK+l:PRINT USING "BEGRENZINGSVLAK /f/f",JVLAK 173 INPUT "C(L) TOV REF.VLAK ",DB 174 JVLAK$="VLAK"+NUM$(JVLAK)+";C(L):"+NUM$(DB) 175 INPUT !loPP. TOTAAL GEVELVLAK ", SG 180 INPUT "GEVELSTRUCTUURCORR. " , DL 185 PRINT tlSPECIFIEKE KIERFACTOR,KIERTYPE:" 186 PRINT "O=GEEN KiER,1=POTDICHT(10"'-4),2=GOED DICHT(3.10"'-4)" 187 PRINT "3i 4=NORMALE KIER/NAADAFWERKING(10"'-3) ,RESP .6 .... 12GM EN 2-5CM DIEP" 188 PRINT "5/6=GEEN KIER OF GEEN NAADAFWERKING(3.10"'-3),RESP.6-1212-5CMDIEP" 189 PRINT "7=GEEN KIER/NAADAFDICHTING(10"'-2),8=INVOER CONSTANTE K" 190 INPUT "KIERTYPE ",KTYP 191 IF KTYP(8 GOTO 194:INPUT "WAARDE",KTYP:GOTO 199 194 J$=CVT$$("KTYPE"+NUM$(KTYP),16) 195 REPEAT:READ T$:FOR J=2 TO 8:READ KO,J) 196 K(3,J)=K(3,J)/1000 197 NEXT J:KTYP$(3)=MID(T$,2%,6%):UNTIL T$=J$ 198 RESTORE:GOTO 200 199 FOR J=2TO 8 :K( 3 ,J)=KTYP :NEXT J :J$=CVT$$( "KCONST" , 16) :KTYP$ (3 )=NUM$(KTYP) 200 INPUT "AANT AL GEVELDELEN " , N 220 FOR 1=1 TO N:GOSUB 1000:NEXT I 225 REM 226 REM START BEREKENINGEN 227 REM 230 DD=10*LOG10(VOL/(3*SG»+DL . 240 ST=O 245 FOR J=2 TO 9:RR(J)=0:NEXT J 250 FOR 1=1 TO N 260 ST=ST+RT(I,10)

~ 270 FOR J=2 TO 8

Page 41: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

III 280 RR(J)=RR(J)+S(I)*10 A (-RT(I,J)/10)/SG 112 290 NEXT J 113 300 NEXT I 114 305 PRINT:PRINT:PRINT

blad No

115 310 IF ABS( ST-SG»0.05*SG THEN PRINT "OPP. KLOPT NIET !" ELSE GOTO 350 116 315 PRINT SG:FOR 1=1 TO N:PRINT USING "11111111.11" I,RT(I,10):NEXT I 117 320 GOTO 500 118 330 REM 119 331 REM UITVOER RESULTATENOP BEELDSCHERM 120 332 REM 121 350 PRINT USING OPSCHl$ 63,125,250,500,1000,2000, 122 351 PRINT USING OPSCHll$ 4000, 123 360 PRINT:PRINT:PRINT " R-VLAK (K=O) ";:FOR J=2 TO 8 124 370 DT(I,J)=-10*LOGI0(RR(J» 125 380 PRINT USING "ll/fllIlIlIlIl" DT( 1 ,J), :NKXT J 126 390 PRINT 127 400 FOR L=O TO 3 128 405 PRINT 129 410 PRINT USING" D(NT) ,K=\ \" KTYP$(L); 130 420 FOR J=2 TO 8:DT(L+2,J)=-10*LOG10(RR(J)+K(L,J»+DD 131 425 PRINT USING "llIlIlIlIlIlIf" DT(L+2 ,J), 132 430 NE:XT J . 133 431 LL=L+2:GOSUB 2000 134: 432 M$=" - ":IF DT(L+2,0)<-5 THEN M$=NUM$(DT(L+2,0» 135 436 PRINT:PRINT USING OPSCH2$ DT(L+2,10);DT(L+2,11);M$;DT(L+2,12) 136 440 NEXT L 137 445 GOSUB 8000:PRINT:PRINT:PRINT:IF NVLAK=l GOTO 466 138 447 FOR L=6 TO 9:FOR J=2 TO 8 139 450 DT(L,J)=DT(L,J)+10 A (-(DT(L-4,J)+DB)/10):NEXT J:NEXT L 140 451 IF JVLAK)<NVLAK GOTO 170 141 452 PRINT : PRINT "RESULTAAT TOTALE VERTREK" : PRINT 142 453 PRINT USING OPSCH1$ 63,125,250,500,1000,2000,:PRINT USING OPSCHll$ 4000, 143 454 FOR L=6 TO 9 144 4S5 PRINT:IF L)<9 THEN DO:PRINT USING" D(NT),K==\ \ ",KTYP$(L-6); 145 456 ELSE:PRINT " D(NT) ,K=INVOER"; :DOEND 146 457 FOR J=2 TO 8:DT(L,J)=-10*LOGI0(DT(L,J» 147 458 PRINT USING "11111111111111" DT(L,J); :NEXT J :LL=L:GOSUB 2000' 148 459 M$=" - ":IF DT(L,0)<-5 THEN M$=NUM$(DT(L,O» 149 460 PRINT : PRINT USING OPSCH2$ DT(L, 10); DT(L, 11) ;M$ jDT(L, 12) 150 462 NEXT L 151 463 PRINT:PRINT:PRINT 152 465 GOSUB 8500 153 466 PRINT #16 "EIND":RWIND 1116 154 468 INPUT "PRINTEN" ,J$ :IF LEFT(J$, l%)="J" THEN 600 ELSE .470 155 470 REM 156 471 REM WIJZIGEN EN PRINTEN 157 472 REM 158 473 IF NVLAK)(l THEN DO:INPUT "STOPPEN OF NIEUWE SITUATIE",J$:ELSE 159 475 INPUT "STOPPEN,WIJZIGEN OF NIEUWE SITUATIE",J$:DOEND 160 477 IF LEFT(J$,I%)="S" GOTO 480 161 478 IF LEFT(J$,l%)="W" GOTO 500 162 479 IF LEFT(J$,l%)="N" GOTO 150 ELSE GOTO 470 163 480 PRINT "RESULTATEN PRINT EN BUITEN BASIC VIA ' CO, B2, : 6'" : STOP . 164 500 PRINT : PRINT : INPUT "WIJZIGINGEN GEVELELEMENT, NR", I 165 502 IF I)N PRINT "NIEUWE ELEMENTEN !" ELSE 540

Page 42: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

166 167 168 169 170 171 172 173 174 175 176

.177 178 179 180 181 182 183 184 185 186 • 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214': 215 216 217 218 219 220

505 J=N+1:N=I:FOR I=J TO N:GOSUB 1000:NEXT I 510 GOTO 500 540 IF 1=0 GOTO 230 550 GOSUB 1000:GOTO 500 600 GOSUB 9000:GOTO 470 800 REM 801 REM FOUTMELDING 802 REM 805 PRINT "EEN FOUTJE !":PRINT 810 PRINT "NIEUWE BEREKENINGEN VIA 'RUN 470'" 820 PRINT "NIEUWE START MET HANDHAVEN PRINT-FILE" 830 PRINT "VIA ' RUN 50' ANDERS GEWOON ' RUN'" 840 STOP 1000 REM 1001 REM R-BEPALING GEVELELEMENTEN 1002 REM 1005 PRINT:PRINT 1010 PRINT USING "DEEL 1111",1 1020 INPUT "OPP.:",RT(I,10) 1025 RT(I,0)=I:S(I)=RT(I,10)

blad A9

1030 PRINT "1=ENKELGLAS,2=GELAMINEERDGLAS,3=DUBBELGLAS,4=DUBBELGLAS/GAS" 1031 PRINT "5=STEEN ,6=BORSTWERING, 7=DAKCONSTRUCTIE ,8=VENTILATIE" 1032 PRINT "9=INVOER R/OCT,10=INVOER DN/OCT" 1033 PRINT:INPUT "TYPE?",T 1034 TYP$(I)="R /OCT " 1035 ON T GOTO 1100,1200,1300,1400,1500,1600,1800,1700,1050,1040 1040 S(I)=10:TYP$(I)="DN/OCT " 1050 FOR J=2 TO 8:PRINT USING "llItlffl" RT(O,J); : INPUT RT(I,J) :NEXT J 1055 DM$(I)=" " 1090 GOTO 1900 1100 REM 1101 REM R ENKELGLAS 1102 REM 1105 INPUT "GLASDIKTE(MM):",D 1110 TYP$(I)=I1GLAS-EI1 :DM$(I)=" "+NUM$(D)+"MM" 1115 PRINT TYP$ (1) ,DM$ (I) 1120 FOR J=2 TO 8: FD=RT(O,J)*D 1125 RT(I,J)=-10*LOGI0(0.00000513+1/(FD~1.33»-16.9 1130 IF FD<8000 GOTO 1150 1135 RT( I,J)=-29 .9*LOG10(FD)+149. 2: IF FD<12500 GOTO 1150 1140 RT(I,J)=12.95*LOG10(FD)-26.4:IF FD<16000 GOTO 1150 1145 RT(I,J)=33.2*LOG10(FD)-111.6 1150 PRINT USING "11111111" RT(I,J), : NEXT J 1190 GOTO 1900 1200 REM 1201 REM R GELAMINEERD GLAS 1202 REM 1205 INPUT "TOTALE CONSTRUCTIEDIKTE(MM) ,GLASDIKTE+1:" ,D 1210 TYP$(I)="GLAS-L":DM$(I)=" "+NUM$(D)+"MM" 1220 PRINT TYP$(I),DM$(I) 1225 FOR J=2 TO 8:FD=RT(0,J)*(D-1) 12,30 IF FD<16000 THEN RT( I,J)=-10*LOG10( 0 .00000513+1/ (FDA 1.33) )-16.9 1240 IF FD)=16000 THEN RT(I,J)=10*LOG10(FD"3.32+1.0E14)-108.6 1250 PRINT USING "lltllllI" RT(I,J), :NEXT J 1290 GOTO 1900

BIB INSTIL' 'T \1 ~\ ... ;~ F' ,;{CEPTIE

Page 43: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

221 1300 REM 222 1301 REM R DUBBEL GLAS 223 1302 REM 224 1305 INPUT "DIKTE-SPOUW-DIKTE(MM):" ,Dl ,B,D2 225 1310 TYP$( I)="GLAS-D" :DM$( I)=NUM$(Dl )+NUM$(B)+NUM$(D2) 226 1311 PRINT TYP$( I) ,DM$(I) 227 1312 IF B)4.5 GOTO 1315 228 1314' D=Dl+D2 :TYP$ (I)="GLS-DL" : GOT a 1220 229 1315 D=(Dl+D2)/2:B=B*Dl*D2/(D*D*D):FOD=2120/SQR(B) 230 131~IF B)64.0 THEN B=64.0 ' 231 1320 IF B<I.0 THEN B=I.0 232 1325 FOR J=2 TO 8:FD=RT(0,J)*D:RT(I,J)=13.33*LOGI0(FD)-14.3 233 1330 IF FD<FOD/2.5 GOTO 1390 234 1332 IF FD<=FOD AND B)15 GOTO 1390

blad AJ CJ

235 1333 RT(I,J)=-6.67*LOGIO(B)+24.7+(16.8*LOGI0(B)-3.8)*LOGI0(2.5*FD/FOD) 236 1335 IF FD<=FOD/l.26 GOTO 1390 237 1337 IF FD)I.26*FOD GOTO 1350 \ 238 1340 RT(I,J)=-6.67*LOGI0(B)+30+(66.4*LOGI0(B)-43)*LOGI0(FD/FOD) 239 1345 IF B)15 GOTO 1390 . \ 240 1347 RT(I,J)=19.7+60*LOGI0(FD/FOD):IF FD)FOD GOTO 1390 241 1348 RT(I,J)=23.6-1.67*LOGI0(B)+(16.6*LOGI0(B)-39)*LOGI0(1.26*FD/FOD) 242 1349 GO TO 1390 243 1350 RT(I,J)=25*LOGI0(FD)+12.5*LOGID(B)-60 244 1355 IF FD<5000 GOTO 1390 245 1360 RT(I,J)=RT(I,J)-16:IF FD)21800 GOTO 1390 246 1365 IF FD)13600 AND ABS«DI-D2)/(Dl+D2»<0.19 GOTO 1390 247 1370 RT(I,J)=12.5*LOGI0(B)+32.5:IF ABS«DI-D2)/(Dl+D2»)=0.19 GOTO 1390 248 1375 IF FD<7350 THEN 1390 ELSE'RT(I,J)=RT(I,J)-5 249 1380 IF FD<11500 THEN 1385 ELSE 1390 250 1385 RT( I ,J)=-25*LOGI0( FD)+l2 .5*LOGI0(B)+l30 251 1390 PRINT USING "UIIII" RT( I,J), :NEXI' J 252 1399 GOTO 1900 253 1400 REM 254 1401 REM R DUBBEL GLAS MET GASVULLING 255 1402 REM 256 1405 INPUT "DIKTE-SPOUW-DIKTE(MM): \I, Dl ,B ,D2 257 1410 TYP$(I)="GLS-DGIt :DM$(I)=NUM$(Dl)+NUM$(B)+NUM$(D2) 258 1411 PRINT TYP$(I),DM$(I) 259 1412 IF B)4.5 GOTO 1415 260 1414 D=Dl+D2 :TYP$(I)="GLS-DL" : GO TO 1220 261 1415 D=(Dl+D2)/2:B=B*Dl*D2/(D*D*D):FOD=2120/SQR(B) 262 1417 IF B)64.0 THEN B=64.0 263 1420 IF B<I.0 THEN B=I.0 264 1425 FOR J=2 TO 8:FD=RT(0,J)*D:RT(I,J)=13.33*LOGI0(FD)-14.3 265 1430 IF FD<FOD/2.5 GOTO 1490 266 1432 IF FD<=FOD AND B)lO GOTO 1490 267 1433 RT(I,J)=-6.67*LOGI0(B)+24.7+(16.8*LOGI0(B)-3.8)*LOGI0(2.5*FD/FOD) 268 1435 IF FD<=FOD/l.26 GOTO 1490 . 269 1437 IF FD)I.26*FOD GOTO 1450 270 1440 RT( I ,J)=-6.6 7*LOGI0( B)+30+( 66*LOGlO(B)-3l)*LOGI0(FD/FOD) 271 1445 IF B)10 GOTO 1490 272 1447 RT(I,J)=19.7+72*LOGI0(FD/FOD):IF FD)FOD GOTO 1490 273 1448 RT(I,J)=23.6-1.67*LOGI0(B)+(l6.6*L9GI0(B)-39)*LOGI0(l.26*FD!FOD) 274 1449 GOTO 1490 . 275 1450 RT(I,J)=35*LOGI0(FD)+17.5*LOGI0(B)-93

Page 44: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad All

276 1460 IF FD(SOOO GOTO 1490 277 1465 IF FD)24000 THEN RT(I,J)=25*LOGI0(FD)+17.5*LOGI0(B)-73 ELSE 1470 278: 1466 GOTO 1490 279 1470 RT(I,J)=17.5*LOGI0(B)+36.5:IF ABS«DI-D2)/(Dl+D2»)=0.19 GOTO 1490 280 1475 IF FD(6250 GOTO 1490 . 281 1478 IF FD )12500, THEN RT(I,J)=25*LOGlO(FD)+17.5*LOGI0(B)-73 ELSE 1485 282 1480 GOTO 1490 283 1485 RT(I,J)=-35*LOGI0(FD)+17.5*LOG10(B)+173 284 1490 PRINT USING "IfIIlNI" RT( I ,J) ,:NEXI' J 285 1499 GOTO 1900 286 . 1500 REM 287 1501 REM R STEENACHTIGE MATERIALEN 288 1502 REM 289 1505 INPUT IISPOUW OF ENKEL",B$ 290 1507 IF LEFT(B$,l%)=IISII THEN B$="SP" ELSE B$="EN"

. 291 1510 INPUT ~IMASSA(KG/M"2):II,D

292' 1515 TYP$( I)="STN-II+B$ :DM$( I)=NUM$(D)+IIKG/M2" 293 1517 PRINT TYP$(I),DM$(I) 294 :,1520 FOR J=2 TO 8:FD=RT(0,J)*D/10QO 295 1525 IF B$="SP" THEN 1570 296 1530 IF D)150 THEN 1550 297 1535 RT(I,J)=16.6*LOGI0(FD)+14.3:IF FD)15 THEN RT(I,J)=5*LOGI0(FD)+28 298 1540IFFD=)62 THEN RT(I,J)=30*LOGI0(50+FD)-24.5 299 1545 GOTO 1580 _ 300 1550 RT(I,J)=16.6*LOGI0(FD)+13:IF FD)40 THEN RT(I,J)=11.6*LOG10(FD)+21 301 1555 IF FD=)100 THEN RT(I,J)=-20*LOGI0(0.001+1/FD)+5.0 302 1560 GOTO 1580 ' 303 1570RT(I,J)=16.6*LOGI0(FD)+14.3:IF FD)20 THEN RT(I,J)=11.6*LOGI0(FD)+21 304 1575 IF FD=)75 THEN RT(I,J)=-25*LOGI0(0.0008+1/FD)-3.5 305 1580 PRINT USING IIllIflllI" RT( I,J), :NEXI' J . 306 1590 GOTO 1900 307 1600 REM 308 1601. REM R LICHTE BORSTWERING 309 1602 REM 310 1603 PRINT "1=ENKELE PLAAT,2=DUBBEL,LICHT,STIJF,3=DUBBEL,LICHT,SLAP" 311 1604 PRINT "4=DUBBEL, ZWAAR, SLAP ,5;;DUBBEL, ZWAARDER, SLAPPER" 312 1605 INPUT "TYPE 1,2,3,4 OF 5?",D 313 1610 TYP$( I)="BRSTWG" :DM$( 1)=" TYPE"+NUM$(D)· 314 1620 J$=CVT$$("BW"+NUM$(D),2) 315 1622 PRINT TYP$(I),DM$(I),J$ 316 1625 REPEAT 317 1630 READ T$:FOR J=2 TO 8:READ RT(I,J):NEXI' J 318 1635 UNTIL T$=J$ 319 1640 RESTORE 320 1680 FOR J=2 TO 8 : PRINT USING "IFlNfll" RT(I,J), :NEXI' J 321 1690 GOTO 1900 322 1700 REM 323 1701 'REM DN(A=10 M"2) VENTILATIEVOORZIENING 324 1702 REM 325 1703 PRINT "VENTILATIEVOORZIENING , LUCHTDOORLAAT TOV 10"-3 W3/S" 326 1704 INPUT V:IF V<1 THEN V=1 327 1705 PRINT "1=OPENING,2=ROOSTER MET GAAS" 328 1706 PRINT "3=ENIGSZINS-,4=REDELIJK-,5=GOED-GEDEMPTE VOORZIENING" 329 1.707 INPUT "TYPE' 1 , 2,3,4 OF 5", D 330 1710 TYP$(I)="VENTIL":DM$(I)=" TP"+NUM$(D)+NUM$(V)+"M.W3/S":S(I)=10

Page 45: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

331 1720 J$=CVT$ $ ("SS"+NUM$ (D) ,2) 332 1722 PRINT TYP$(I),DM$(I),J$ 333 1723 ON D GOTO 1725,1726,1727,1728,1729 334 1725 L=0.005:GOTO 1730 335 1726 L=0.050:GOTO 1730 336 1727 L=0.10:GOTO 1730 337 1728 L=0.15:GOTO 1730 338 1729 L=0.25 339 1730 PRINT USING "BRUTO AFMETING CA. illI.IIM X 11.IIIIIIM",V*0.2;L 340 1731 RT(I,10)=V*L*0.2 341 1732 REPEAT

blad A12

342 1733 READ T$:FOR J=2 TO 8:READ 'RT(I,J):RT(I,J)=RT(I,J)-10*LOGI0(V):NEXT J 343 1735 UNTIL T$=J$ . 344 1740 RESTORE 345 1750 S(I)=10 346 1780 FOR J=2 TO 8:PRINT USING "IIIIfN!" RT(I,J),:NEXT J 347 1785 SLEEP 5 348 1790 GOTO 1900 349 1800 REM 350 1801 REM R SAMENGESTELDE DAKCONSTRUCTIES 351 1802 REM 352 1803 PRINT "1=PANNEN;2=PAN+KIEREND BESCHOT;3=2 MET DICHT BESCHOT;4=3+WOL" 353 1804 PRINT "5=PAN,BESCHOT,PLAFOND;6=5+WOL;7=PLAT DAK MET KIEZELS+PLAFOND" 354 1806 INPUT "TYPE 1,2,3,4,5,6 OF 7",D 355 1810 TYP$(I)="DAK ":DM$(I)=" TYPE"+NUM$(D) 356 1820 J$=CVT$$("DK"+NUM$(D),2) 357 1822 PRINT TYP$(i),DM$(r),J$ 358 1832 REPEAT 359 1833 READ T$:FOR J=2. TO 8:READ RT(I,J):NEXT J 360 1835 UNTIL T$=J$ 361 1840 RESTORE 362 1880 FOR J=2 TO 8:PRINT USING "11111111" RT(I,J),:NEXT J 363 1890 GOTO 1900 364 1900 REM 365 1901 REM BEREKENING A-GEWOGEN ELEMENT-ISOLATIE 366 1902 REM 367 1910 RT(I,9)=0 368 1920 FOR J=2 TO 8:RT(I,9)=RT(I,9)+10 h «V(J)-RT(I,J»/10) 369 1925 NEXT J 370 1930 RT(I,9)=-10*LOGI0(RT(I,9»:RT(I,9)=INT(RT(I,9)+0.45) 371 : 1980 PRINT USING" RAS: l1li1111" RT(I,9), 372 1990 RETURN 373 2000 REM

. 374 2001 REM I-LU/DNT(W)/DNT(AS) BEREKENING 375 2002 REM I-LU 376 2050 FOR 1=3 TO 7:D(I)=DT(LL,I)-N(I):NEXT I 377 2070 U=D(4):S=D(3):IF D(3)-D(4)<0 THEN 2100 378 2080 S=D(4):U~D(3) 379 2100 W=(D(3)+D(4»/5:FOR 1=5 TO 7:W=D(I)/5+W 380 2150 IF (U-D(I»<=O THEN 2300 381 2200 IF (S-D(I»>=O THEN 2250 382 2220 U=D(I):GOTO 2300 383 2250 U=S:S=D(I) 384 2300 NEXT I 385 2350 DV=S+4:S=(S+U+4)/2:IF (W-DV»O THEN W=DV

Page 46: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

386 2400 IF (W-S»O THEN W=S 387 2410 IF FRAC(ABS(W»><0.5 THEN 2420 388 2415 IF FRAC«ABS(W)-0.5)/2)=0 THEN W=SGN(W)*(ABS(W)-1) 389 2420 DT(LL,10)=SGN(W)*INT(ABS(W)+O.5) 390 2500 REM DNT(AS) 391 2505 W=O:FOR 1=2 TO 8:W=W+10"«V(I)-DT(LL,I»/10):NEXT I 392 2510 DT(LL,12)=-10*LOG10(W) 393 3000 REM DNT(W) 394 3005 DV=INT(DT(LL,5)-N(5»-2:W=0 395 3010 U=O:FOR 1=3 TO 7:S=DT(LL,I)-N(I)-DV:IF S<O THEN U=U+S 396 3015 NEXT I 397 3020 U=U/5:IF U=-2 GOTO 3200 398 3022 IF U>-2 AND W<-2 GOTO 3200 399 3025 W=U 400 3030 IF U<-2 THEN DV=DV-1 ELSE DV=DV+1 401 3040 GOTO 3010 402 3200 DT(LL,11)=DV+50 403 3210 W=-5:FOR 1=3 TO 7:S=DT(LL,I)-N(I)-DV 404 3220 IF S<W THEN W=S 405 3230 NEXT I 406 3250 DT(LL,0)=SGN(W)*INT(ABS(W)+0.5) 407 3500 RETURN 408 8000 REM 409 8001 REM UITPRINTEN RESULTATEN 410 8002 REM 411 8010 FOR 1=1 TO 10:PRINT #16:NEXT I 412 8020 PRINT 1116 "GEVEL GELUIDREDUCTIE-:-BEREKENING" 413 8025 PRINT 1116 "================================" 414 8027 PRINT 1116

blad AU

415 8030 PRINT 1116 USING " PROJECT: \ \" ,PROJ$ 416 8031 PRINT 1116 11 ";JVLAK$ 417 8032 PRINT 1116 USING" GEVELOPP: IfllIl.# W2 VOLUME: 111111.11 M"3" ,SG;VOL 418 8035 PRINT 1116 USING" C(G) 11I1f1",DL 419 8040 PRINT #16 USING t! REFERENT IE-BRON SPECTRUM: \ \ (=R)" S$ 420 8050 PRINT #16 421 8060 PRINT 1116 " TYPE, OPPERVLAK EN ISOLATIE GEVEL-ELEMENTEN (OCTAVEN/ A-GEWOGEN)" 422 8070 PRINT 1116 U ELEMENT OPP"; 423 8080 FOR 1=2 TO 8: PRINT 1116 USING "ltllflflllt! RT(O,I);:NEXT I 424 8090 FOR 1=1 TO N:PRINT #16 425 8095 PRINT 1116 USING "1111\ \ \ \", RT(I,O) ;TYP$(I) ;DM$(I); 426 8096 PRINT 1116 USING "1111.11" RT(I,10); 427 8100- FOR J=2 TO 8 : PRINT #16 USING "l/lIlfllIl" RT(I,J); 428 8110 NEXT J 429 8115 PRINT 1116:PRINT fI16 USING" 111111" RT(I,9), 430 8120 NEXT I 431 8150 PRINT 1116:PRINT 1/16:PRINT 1116 432 8160 PRINT 1116 "RESULTATEN":PRINT 1116 u==========":PRINT 1116:PRINT 1116 433 8200 PRINT 1116 USING OPSCH1$ 63,125,250,500,1000,2000, 434 8201 PRINT 1/16 USING OPSCH11$ 4000, . 435 8210 PRINT 1116 : PRINT 1116 :PRINT 1116 " R-VLAK (K=O) "; :FOR J=2 TO 8 436 8230 PRINT 1116 USING "Ilit/t/lit/III" DTC 1 ,J), :NEXT J 437 8240 PRINT 1116 438 8250 FOR L=O TO 3 439 8260 PRINT 1116 440 8270 PRINT 1t16 USING" DeNT) ,K=\ \" KTYP$(L);

Page 47: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

441 442 443 444 445 446 '447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483

8280 FOR J=2 TO 8 : PRINT 1116 USING "1111111111111111 DT(L+2 ,J); 8300 NEXT J 8310 M$=" - ":IF DT(L+2,0)<-5 THEN M$=NUM$('DT(L+2,0»

blad A14

8320 PRINT 1116:PRINT 1116 USING OPSCH2$ DT(L+2,10);DT(L+2,1l);M$;DT(L+2,12) 8330 NEXT L . 8340 FOR 1=1 TO (24-2*N) :PRINT 1116 :NEXT I 8490 RETURN 8500 REM 8501 REM 8502 REM

PRINT-UITVOER TOTAAL BIJ MEER VLAKKEN·

8510 FOR 1=1 TO lO':PRINT 1116 :NEXT I 8520 PRINT 1116 "GEVEL GELUIDREDUCTIE-BEREKENING" 8525 PRINT 1116 "===============================" : PRINT 1116

:' 8527 PRINT 1116 USING " PROJECT: \ 8530 PRINT 1116 " TOTAAL RESULTAATMET .MEERDERE VLAKKEN" 8535 PRINT 1116 USING" AANTAL VLAKKEN:' IIIIII",NVLAK

. \" ,PROJ$

8550 PRINT 1116 : PRINT 1f16 " CONSTRUCT IE EN SITUATIE GEGEVENS:" 8555 PRINT 1116 " ZIE DETAIL UITVOER PER VLAK" : PRINT 1116. 8560 PRINT '/116 USING" REFERENT I E-BRONSPEC,-\ RUM: \ 8565 PRINT 1116 : PRINT 1116 :PRINT 1116 8570 PRINT 1116 "RE SU LT AT EN" : PRINT 1116, "=========="

\ (=R)",S$

8575 PRINT 1116:PRINT 1116:PRINT 1116 USING OPSCH1$ 63,125,250,500,1000,2000, 8580 PRINT 1116 USING OPSCH11$ 4000, 8590 PRINT 1116:FOR L=6 TO 9 8600 PRINT 1116 :IF L><9 THEN DO:PRINT 1116 USING" D(NT) ,K=\ 8605 ELSE : PRINT 1116 " D(NT) ,K=INVOER"; :DOEND

.8610 FOR J=2 TO 8:PRINT 1116 USING "11I1I1I1t1t1l1",DT(L,J);:NEXT J 8620 PRINT 1116' , 8625 M$=" - ":IF DT(L,0)<-5 THEN M$=NUM$(DT(L,O» 8630 PRINT 1116, USING OPSCH2$ DT(L,10);DT(L,11);M$jDT(L,12); 8633 PRINT 1116 8635 NEXT L 8650 ,FOR 1=1 TO 25:PRINT 1116:NEXT I 8990 RETURN 9000 REM 9001 REM 9002 REM

\

OVERHEVELEN UITVOER~FILE(B1) NAARPRINT-FILE(B2)

9010 INPUT LINE 1116 DUM$ :IF LEFT(DUM$ ,5%)=11 EIND" GOTO 9090 9020 PRINT 1126 LEFT(DUM$,80%) 9030 GOTO 9010 9090 RwIND 1116 9100 RETURN EOT ••

\ ",KTYP$(L-6);

Page 48: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

BIJLAGE B: Waarden van enkele correcties en de kierfactor

B.i Gevelstructuurcorrectie Cg

De gevelstructuurcorrectie is als voigt gedefinieerd:

Hierin is:

C g

L . gevelvlak

C == L - L' + 3 g 2m gevelvlak

de gevelstructuurcorrectie

het geluiddrukniveau op 2m v~~r de buiten­

ste gevelbegrenzing, inclusief eventuele

gevelreflecties

het geluiddrukniveau dat gemiddeld heerst

op h~t eigenlijke gevelvlak

Voor een vlakkegevel geldt in elke octaafband:

L+ 3' invall"end

\

L gevelvlak = L + 6 invallend

en dus:

C 0 g

blad B1

(B1)

(B2)

'V~~r een niet na~r het waarneempunt reflecterende gevel geldt:

L gevelvlak

en daarmee:

= Linvallend + 6

C == - 3 g

(3B)

,

Page 49: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad B2

Voor andere vormen van de geve1, zoa1s bij ba1kons of galerijen,

kan geluidafscherming en extra geluidreflectie optreden, waardoor

de geveistructuurcorrectie minder eenvoudig is aan te geven en in

principe ook frequentie-afhankelijk zal zijn.

Door extra reflecties, b.v. tegen een bovenhangend balkon zal gelden

L + 3 ~ invallend

L L + 6 geveIvlak > invaIIend

en daarmee: C < a dB g

• (B4)

Daarentegen zal geluidafschermingen door b.v. een galerijrand resul­

teren in

~ L + 3 invallend ( B5)

Iv1ak < Linva1Iend + 6

en dus: > 0 dB

Op basis van een beperkte hoeveelheid meetgegevens [ 4 ] is in

tabel B1 een vooriopige indicatie gegeven van de geveistructuuc­

correctie in diverse situaties, waarbij vooralsnog een constante

waarde voor het Ie frequentiege"bied is gehanteerd.

Page 50: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad B3

TABEL B.l: Gevelstructuurcorrectie voor diverse gevelstructuren. (voorlopige waarden)

GEVELSTRUCTUUR

categorie omschrijving 1) C in dB g

a

b

c

d

e

f

- vlakke, vertikale gevel;dieptevariaties . kleiner dan 0,4 m

- ondiep, inpandig balkon met open of gesloten balustrade

- galerij of uitpandig balkon zonder plafond, diep of ond ,open of gesloten balustrade (zie ook eategorie e)

- galerij of uitpandig balkon met plafond, ondiep met open of gesloten balustrade diep met open balustrade

- galerij of uitpandig balkon met plafond, diep met geslgten balustrade (zie ook eategorie e)

o

-1

-2

- inpandig balkon met gesloten balustrade, -3 diep (zie ook categorie e)

1 d O· 2 2) dit is van toepassing voor de vo gen e gevelstruc- tot + turen bij diepe balkons of galerijen als voor het volledige gevelvlak tot bovenrand de geluir:Jbron door vloer of gesloten balustraderand aan het zieht wordt onttrokken:

- geen plafond of goed absorberend plafond

- b inpandige balkons tevens gedeeltelijk (50%) absorberende zijvlakken.

- hellende gevel (dakvlak al dan niet met een uit­bouw) met een zodanige helling dat geen geluid­ref lee tie optreed naar het referentiepunt voor dit vlak, d.w.z. direete lijn tussen bron en gespiegeld referentiepunt verloopt niet via het hellende vlak.

-3

1) Er is sprake van 'diep' bij een diepte groter of gelijk aan de verdiepingshoogte; in aIle andere gevallen wordt het balkon of de galerij als ondiep beschouwd.

2) De juiste waarde wordt bepaald door de detaillering, toegepast absorptiemateriaal en opbouw gevelvlak.

NOOT: Teneinde de gevelstructuurcorrectie nader te bepalen wordtonder­

zoek op modelschaal overwogen.

Page 51: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

I brad B4

B.2 Kier.factor K

De kierfactor K is feitelijk als voIgt opgebouwd:

SkO 1er

R kier

K = SkO 1er S gevel

-Rk ° /10 l.er 10

2 = oppervlakte in m van kieren en naden

geluidisolatie van de kier, afhankelijk van de breedte

en diepte van de kier

(B6)

De geluidisolatie vaneen goed gedefinieerde spleet is redelijk

bekend [ 15 J . De toepassing hiervan op kieren en, naden stuit echter

op de praktische onmogelijkheid de afmetingen (nodig voor de bepaling

van Sko en Rko ) redel l.er 1er te kunnen aangev~n.

Op basis van globlale aannamen over de mate waarin naden en kieren in

gevels kUnnen voorkomen en de daarbij typerende afmetingen van die

kieren; zijn er aan de hand van de gegevens uit [ 5,15 ] v~~r enkele

typen kieren kierfactoren leid. Een vergelijking tussen meet- en

berekeningsresultaten geeft aan dat opdeze·wijze met een in eerste

instantie als frequentie-onafhankelijke aangenomen kierfactor een re­

delijke over.eenstemming met meetgegevens wordt verkregen [ 16 ] 0

De geluidisolatie van spleten. is feitelijk afhankelijk van de frequent-ieo

Dit kan met name tot uiting komen claar waar deze geluidisolatie gering

is: bij de frequentie waar.spleetresonantie optreedt en bij lage fre­

quentieso

Op grond van dezelfde aannamen ten aanzien van hoeveelheid kieren en

kierafmetingen als hiervoor, kan vanuit de frequentieafhankelijke

kierisolatie ook een frequentieafhankelijke kierfactor worden afge­

leid. Hiermee blijkt over hetalgemeen het frequentieverloop van het

gevelverschil iets beter te worden benaderd, met name het optreden

van een dip ten gevolge va~ de spleetresonantie.

Page 52: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad B5

Deze verfijning blijkt echter geen wezenlijke verbetering op te

leveren voor de gemiddelde overeenstemming tussen meting en bere­

kening voor -het gevelverschil in dB(A) voor een bepaald referentie­

spectrum.

In tabel B2 ziJn voor een aantal geveltypen de 'kierfactoren zowel

in octaafb~nden gegeven als frequentiegemiddeld (zie ook figuur

- Bl).

In het co~puter-rekenprogramma (bijlage A) zijn de octaafband~waarden

opgenomen.

Page 53: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad B6

TABEL B.2: Kierfactor voor diverse typen gevels.

GEVELTYPE K "

OMSCHRIJVING Gem. In octaven met middenfrequentie (Hz)

Type 63 125 250 500 lk 2k 4k

0 zonder naden en kieren 0 0 0 0 0 0 0 0

1 met volledig afgedichte 10-4 4 2 1 0,6 0,4 1,3 1,3 xl0-4

naden en kieren

2 met redelijk afgedichte 3.10-4 16 8 4 2,5 1,6 5 5 x10-4

naden en kieren

3,4 normale naadafwerk ing en 10-3

normale kierafwerking

of weinig te openen de-

len (beperkt aantal

kleine te openen delen:

3 naden en kieren diep 4 2 1 0,6 0,5 3,2 1,6 xl0-3

(60 - 120 mm)

4 naden en kieren ondiep 8 4 2 1,3 0,8 0,6 2,5 x10- 3

(20 - 50 mm)

5,6 normale naadafwerking ~.10-3

en te openen delen

~onder kierdichting

5 naden en kieren diep 10 5 2,5 1,6 1,3 8 4 xl0- 3

(60 - 120 nun)

6 naden en kieren ondiep 20 10 5 3,2 2 1,6 6 xl0- 3

(20 - 50 mm) ,

7 veel naden en kieren 10-'2 4 2 1 0,6 0,4 1,3 1,3 xl0-2

zonder voorzieningen

Page 54: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad B7

-10 19 I

d

, 1

!

6 l I

(

I

5

!

I j...-f.-' ~ I-- ~1-.. ( j.......-I-" I 1 4

I~ v j....--V I

l.---' ........ :

~- --r- ~ft' ( I - . , ;,

vV I-- I 1'\ Y 3 V -"1'"

---~ 10-- .... - I i I ,

3

I I-"" ..... 1-- I rr ~ 4 ~ ~ ..- i'." ~ -\ [.....-'i--'" 7 I

'~ i' V i

ffR t..,.....- l.---' I

rl 001 I • : I , I

I ,

: : ,

1

I I

I I I

31,5 63 125 250 500 1000

FrCUUR B.l: Kierfactor in octaafbanden ( -10

geveltypen. Zie tabel B2

2000 4000 ... 8000 Hz

K) voor enkele

Page 55: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad B8

B.3 Buitenniveaucorrectie CL

De geluiddrukniveaus buiten v~~r deverschillende begrenzingsvlakken

van een geyel moeten worden gerelateerd aan ~en referentiepunt om te

kunnen spreken van een genormeerdgeluidniveauverschil van die gevel.

Dit vindt plaats' via een correctie op de deel-gelbidniveauverschillen

voor elk begrenzingsvlak welke in het algemeen is gedefinieerd. als:

CL . = ,1

L -L 2m; referentiepunt 2m, begrenzingsv~ak: (B 7)

Voor begreozingsvlakken ~aarop vanafde bron geen direct zicht mogel k

is zal deze term veelal zeer groot zijn en kan daarmee het betreffende

begrenzingsvlak buiten beschouwing worden gelaten. Als de samenstelling

van de gevel echter aanleiding geeft om deze indirecte (afgeschermde)

overdrachtsweg toch in rekening te brengen,dan moet hierbij als niveau

op 2m voor dat begrenzingsvlak het geluiddruknlveau.zonder directe bij­

dragevan de bron' worden gehanteerd.

Dus feitelijk het naar 2m ge~xtrapoleerde niveau op het (afgeschermde)

begrenzingsvlak:

L . 2m, begrenzingsvlak i

L +C - 3 op vlak g

(B8)

In geval van lijnbronnen is de buitenniveaucorrectie afhankelijk van

de geometrie van de situatie en wordt bepaald door de hoeksector van

de bron waarop vanuit het betreffende.begrenzingsvlak zicht mogelijk

is.

V~~r een aantal geometrische situaties is in tabel B3 de buitenniveau­

correctie gegeven, welke in eerste benadering kan worden gehanteerd

voor elke octaafband.

Page 56: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

I

TABEL B.3: Buitenniveaucarrectie in dB voor enke1e

bron-geve1orientaties bij 1ijnbronnen.

f

Bron-geve1orientatie Referentievlak

aIle orientaties bij 1uchtverkeer onafhanke li j k referentiev1ak

averige lijnbronnen I

bran 1 ;"c ,..

11 1 ,I ;

(doorsnede 3 hari zon taa 1)

_u_. III( lil:CD .,..

11- I Itl 3 1 s I

(horizontaal) ----.----~ ... ---~-------~--- ,~.--- ~~.-~.-----.. -. -.~.-

(horizontaal) 1 bron n- -

(I( ~ ~ro.dl!ll

3

..

--.• ~, ~--"~-,,<-.,,-"---',,,.'~..--.. ""-",,, ... ~ .. ,~-, (vertikaal) 1

\. 2; \.

blad B9.

C1

in dB

0

CL2 ,CL3=+3

C12=0,C11=-3

CL=O voor alle

v1akken 1 tIm 5

CL2 =101g 180-0'. 90-0'.

180-0'. CL3 =101g 90+0'.

C11=101g 90+0'.

180-0'.

CL2 =101g 90+0'. 90-0'.

.

CL2 »5

I "-2 eLl = 0

I i I !

\. I ,

~ bron /

-"'--"-'- .. 0""--___ , •. _. M. __ ' ___ ~_~~· .~", ... , ___ ... _ •• _".~_~,_. ."#_~,,~.~--.-.--~-~, ... . -._ .. , ~----.~

_. __ . -

( vertikaal) . , 1 CL2 = 0

1.

" 2 CL1 :: 0

" "-I "- ....

"- <J) bron .... .. 1) Als de 1ijnbron beperkt in lengte is, met t.o.v. van de lood1ijn opde

weg vanuit vlak 1 een maximale hoek naar links en rechts van resp.

13 1 en I3r dan worden de termen resp. 180 - 0'.-+f.\+90-0'.,90+0'.-l3r

+a en

90-0'. --13 -CI. 1

Page 57: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

B.4 Gevelreflectieterm C r

blad B 1 0

Door de aanwezigheid van de gevel is het geluiddrukniveau v~~r deze gevel

in het algemeen hoger dan het geluiddrukniveau op hetzelfde punt

zonder aanwezigheid van de gevel (geluiddrukniveau van het invallend

geluid).

De mate van deze verhoging is afhankelijk van mate waarin de betref­

fende gevel het geluid reflecteert. Deze gevelreflectie zal in het

algemeen afhankelijk zijn van de gevelstructuur.

De gevelreflectieterm C is gedefinieerd als: r

C = L - L r 2m, V~~r gevel 2m, zonder

gevel­reflectie

=L -L 2m, voor invallend

gevel

Voor elk van de bij de gevelstructuurcorrectie gehanteerde gevel­

categorien is in tabel B4 een indicatie gegeven van de gevelreflec-

tieterm C • r

TABEL ~4: Gevelreflectieterm in dB voor enkele gevelstructuren

. Categorie gevelstructuur C in dB

r

+3 1 )

a zie omschrijving

b +3 tabel BI

c +3

d +3

e +3 ,

f 0

(B9)

I) Gegevens zonadig aan te passen aan de resultaten van madelanderzaek;

zie noat blad B3.

Page 58: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad Cl

BIJLAGE C Karakteristieke geluidreducerende eigenschappen

van geveldelen en gevelelementen.

c.l Algemeen

Ten behoeve van berekening van de geluidreductie door gevels

is in het kader van het ICG-onderzoek OVL-12 een literatuur­

studie verricht naar de geluidisolatie van een groot ~antal

typen constructies die in gevels (kunnen) wordeD toegepast I 9 ] •

Hieruit zijn v~~r die typen constructies karakteristieke

geluidisolatie-curven afgeleid in de vorm van tabellen en

figuren.

Ten behoeve van een handzame toepassing in een computer­

rekenmodel zijn deze karakteristieke curven in formule-vorm

omgezet. De daarbij optredendeonvermijdelijke afwijkingen

zijn zodanig beperkt, zeker in het licht van de totale

spreiding in de verzamelde meetgegevens, dat in de samen­

vattende publikatie van deze literatuurstudie de tabellen,

ter voorkoming van verwarring, aan de formule-resultaten

zijn aangepast[ 10 ]. Deze zelfde resultaten zijn gedeel­

telijk ook in [ 2 ] opgenomen.

Bij de omzetting in formulevorm is voor dubbel glas behalve

van de gegevens uit [ 9 ] ook gebruik gemaakt van e.nkele

(recente) aanvullende meetseries [ 12,13 ] en enkele interne

meetresultaten welke niet v~~r publikatie zijn vrijgegeven.

Dergelijke meetresultaten zijn ook gebruikt om althans enige

indicatieve gegevens te verkrijgen over gevelelementen die

niet in [ 9 ] zijn besproken.

De aanpak bij het omzetten van al deze gegevens in formule-, , ,

vorm zal hierna kort worden besproken waarbij de formules

voor de diverse typen constructies worden gegeven. Deze ,

formules worden ook in enkele figuren weergegeven en toege-

licht.

Page 59: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

c.2

C.2.l

C.2.2

blad C2

Geluidisolatie van geveldelen

enkel glas

De geluidisolatie van enkelglas is in eerste instantie afhan­

kelijk van de frequentie en de diktej

(R = 19 fdj f = middenfrequentie octaafband,d ~ dikte glas).

De (theoretisch) te verwachten invloed van factoren als

afmeting, demping en. randinklemming komt onvoldoende 'syste­

matisch in de meetg~gevens tot uiting om te kunnen worden

~erwerkt~ De gegevens uit [ 9] in octaafbanden kunnen als

voIgt worde'n berekend:

fd (Hz. mm) < 8000: R -10lg (5,13.10.,.6 + (fd) -1,33 ) _ 16,9

8000 ~ fd < 12500: R ":29,9 19 (fd) + 149,2

12500 ~ fd < 16000: R 12,95 19 (fd) - 26,4

fd ~ 16000 R 33,2 19 (fd) 111,6

In figuur c1 is de isolatie als functie van het

produkt f.d in Hz.m (=kHz.mm) volgens deze formules ,weer-

gegeven.

gelamineerd ~

Voor beglazing opgebouwd uit twee (of meer) glaslagen met

een min of meer flexibele kunststof tuss~nlagen wordt in

[ 9 ] een benadering gegeven, uitgaande van de karakteris-2

tieke curve v~~r enkel glas hij,gelijke massa per, m

(gelijke totale dikte van de glaslagen).

(cl)

Uitgaande van de formules c1 levert deze benadering de volgen­

de formules:

fd < 16000 :R= - 10 19

fd ~ 16000 :R= 10 19

(5,13.10-6

+ (fd)~1,33) -16,9

(1014 + (fd)3,32) -108,6

Als van de gelamineerde beg lazing niet de glaslaagdikten

maar aIleen de totale dikte van de constructie bekend is,

moet voor deze toepassing in deze formules deze dikte met

1 mm worden verminderd.

(C2)

Deze isolatie is eveneens in figuu'r c1 weergegeven als functie

van het produkt fd in Hz.m met daIs de som van de glaslaag­

dik ten.

Page 60: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

R

0,25 0,5 1 2 4 8 Ih fd in kHz.mm

FIGUUR C. I: Geluidisolatie enkel glas en

gelamineerd glas in octaafbanden.

32

blad C3

64 )P-

Page 61: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

c.2.3

blad <::4

dubbel glas met luehtvul1ing

De isolatie van dubbel glas wordt bepaald door de Hgging van

de spouwresonatie, bij frequenties daaronder door de tota1e

massa van de beide glaslagen en bij hogere frequenties door

een re1atief steile toename met de frequentie.

In meer of mindere mate, afhankelijk van de glas1aagdikten,

treedt ook bij dubbe1 glas een inbreuk nabij de grensfrequentie(s)

op.

Dit theoretiseh te verwaehten verloop van de iso1atie-eurve

~ordt in grote lijnen door de meetgegevens bevestigd [ 9, 12, 13 ], ook a1 treden vrij grote variaties op bij min of meer vergelijk-

bare eonstrueties. Dergelijke variaties treden met name op .rond

de spouwfrequentie waar soms een sterke inbreuk optreedt en soms

nauwe1ijks. Factoren als randink1emmning en demping zullen hierbij

van invloed zijn, maar uit de meetgegevens is in dit opzicht geen

systematiseh verband af te leiden. Daarnaast zal de preeieze

1igging van deze spouwfrequentie binnen de toegepaste bandbreedte

bij de metingen (oetaaf, terts) van belang zijn. '

Bij het af1eiden van berekeningsformules is in eerste instantie

vooral gebruik gemaakt van de tendensen in meetseries, waarbij

eonstruetiedetails zijn gewijzigd bij verder zo goed mogelijk

gelijk blijvende omstandigheden. Hieruit zijn de vo1gende eon­

elusies getrokken:

- de helling boven de spouwresonantie-frequentie bedraagt ge­

middeld 7,5 dB per octaaf; deze hellende lijn versehuift evenredig

met deze frequentie volgens R~ 25 19 (spouwfrequentie).

- ruim onder de spouwfrequentie wordt de isolatie redelijk be­

naderd door die van enkel glas met gelijketotale massa

bij ongeveer gelijke glasdikte treedt een grensfrequentie

inbreuk op in ongeveer gelijke mate als bij enkel glas; deze

inbreuk verdwijnt ongeveer als de glasdikten globaaleen

factor 1,5 of meet versehillen

Page 62: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad CS

- in een gebied ter breedte van bijna twee octaven rond de

spouwfrequentie verloopt de curve min of meer vlak met

soms een inbreuk van enkele dB's rond deze frequentie

- bij een zeer kleine luchtlaag wijkt het bedrag van de

constructie af van het algemene beeld. De verhoogde

demping in kleine luchtlagen is hiervan waarschijnlijk de

oorzaak, waarmee het gedrag gelijkenis vertoont met dat

van gelamineerd glas.

Uitgaande van deze systematiek zijn,formules afgeleid v~~r

het frequentl~gebied bij en boven de spouwfrequentie en ruim

daaronde~ Voor de aansluiting ,tussen deze beide gebieden is,

rekening houdend met het voorlaatste punt, v~~r een soepele

overgang gekozen.

De absolute waarden van de isolatie in de verschillende ge­

biedenziin zO'goed mogeUjk aangepast aan gemiddelde resul­

taten van constructies waarvan een ruim aantal metingen be­

schikbaar waren, met name die welke in meerdere van de diverse

meetseries voorkwamen.

De resultaten zijn in de volgende formules weergegeven

en in figuur C2 geillustreerd, waarbij d1

en d2

de glaslaag­

dikten in mm en b de spouwbreedte in mm voorstellen.

Page 63: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad C6

b < 4,5 R overeenkomstig gelamineerd glas

d (dl

+ d )/2' B = bd d./d3 . 1

2' 1 2 ' 2120 / . 0B' B .$. 64; f d V B

o

fd < fod/2,S of fd ~ fod en B > 15:R=13,33 Ig (fd)~14,3 (a)

B .$. 15:

f d 12,5 .$. fd_.$. f d/1,26:R -6,67 Ig B + (16,8 IgB-3,8)x ,0 . 0

19 (2,5 fd/f d) + 24,7 (c) . o.

f d < fd.$. f d 1,26:R = 601g Ud/f d) + 19,7 o 0 0

f d/l,26<fd < f d: lineaire interpolatie tussen (<::) en (d) o . 0

B > 15: lineaire interpolatie tussen (a) en (b) voor

f d < fd < f d 1,26 o 0

Cd1

- d2)/(d

1 + d

2) < 0,19

f d 1,26 < fd < SOOO:R 0

= 25 19(fd)+12,5 19B 60

5000 .$. fd < -7350:R 12,5 Ig B + 32,5

7350 ~ fd ~1l500 :R -25 Ig(fd) +12,5 19B + 130

11500 < fd < 13600:R 12,5 Ig B + 27,5

fd > 13600:R. 25 19Cfd)+12,5 19B - 76

Cd - d ) / . 2 ) > 0,19

f d 1,26 0

< fd < 5000:R = 25 Ig (fd)+12,5 19B - 60

5000 < fd ;; 21800:R = 12,5 Ig B + 32,5

fd > 21800:R = 25 Ig {fd)+12,5 19B. - 76

(d)

(b)

(C3)

Page 64: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

H

50

40

30

20

,blad C 7 '

I i I I ; iii i /V/ J1 I ~ F 11 ~-jli-+I--+-+-I -t,--1, : ;,' I -1 I i/ I: /: !

I-+--+-_!r-'+' _~_ _I I -'~ /V i I A I i / i I

I :! Ii. IY. ;/0! IX I! 1 I--+--'--+--+--r--;---'r II)f A I! / I I ,)

II,! ':, I I i V I /! ,i / I I : I ~I i ! i I/! / I i/ I :~

I,!I I . VI I V ! ~ afc~ ~.I { I I/} l!/ ! VI ." i"l7" l 1

0,25 0,5 2 4 8 16 32 64

fed + d ) in kHz.mm 1 2

)0.

FIGUUi{ C. 2: Geluidisolatie van dubbel glas met lllchtvlllling

in octaafbanden

Page 65: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

C.2.4

brad C8

dubbel glas met gasvulling

De meetgegevens met gasgevulde construe ties vertonen aanzienlijke

spreidingen, terwijl veelal slechts beperkte informatie beschik-

baar is over de constructie en meetsituatie (fabrikanten-gegevens).

Een direete vergelijking met identieke constructies ~et lucht-

vulling ontbreekt vrijwel geheel. De spouwfrequentie blijkt globaal

overeen te komen met de verwachting bij luchtvulling. In aIle ge-

vallen blijkt de sti.jging met de frequentie boven de spouwfrequentie

groter te zijn dan bij luchtvulling; het verschil is roms gering en roms aanzienl ijk.

Als globale, conservatieve indicatie van de isolatie van dubbel

glas met gasvulling is op grond hiervan gekozen voor een identieke

opzet als met de formules C3 met een helling van 10,5 dB per

oetaaf in plaats van 7,5 4B per oetaaf. Dit resulteert in de vol-

gende aanpassingen, geillustreerd in figuur C3.

De grens v~~r formule C3,a ligt bij B=10, en formule C3,b wordt:

R = 35 Ig (fd) + 17,5 19 B - 93

Het verdere verloop is in essentie g~lijk met aanpassingen aan

het steiler verloop volgens formule c4.

(C4)

Page 66: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad c9

R

~:Li It' r,,,,-,--I~-f j---- ,I, 1 " !! I -mr Jl I

i' I -. ,

1

B=&4 I I , <

i I I i i t j 1 I

601--+-1---11 ---1-<;,' --I I-I; I [I V i II' r i I B/~l i . Ii

I . I I i J I t-' Ill' -I'

I ! I I V i I ! ! V.! J i 50 I--+--I---i-+

!I ~'I. II Y": II ! III Iii [ ,i I I _ Ii I ! 1 1--+--+-+--+ I I' v I U~ ,i / II I, I IV 1.1 i "I /

40 1--+-~-+--+---+-+-Y1+-1 -1"-+-11 I I /,' X< I • I I I JL.' dl~d) i < : Iii 'Ii " ~ -=- -I- -. ! I

30

i I I / I i r I I V! "'-.,_ V! I

I II JI i I I; / I I 1'-. / I !

II :' Uf ~ I II Ii 'i Ii! I y~ 'T\ I /I I I I! ! :

2o~~+<_~/+I~k~~~:~~ril4-\~l/~II~1 +-~II +1-r+I~i-+~l __ ~.~! ! liY"1 : I j'l I I i I Ii II i! I 1 ...... i""""'1 I ,I I; I Iii I ! ~' ',I I 'ii i I

0,25 0,5 2 4 8 16 32 64

f (d 1 + d2) in kHz. mm .,....

FIGUURC.3: Geluidisolatie van dubbel glas met gasvulling

in octaafbanden

Page 67: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

c.2.S

blad . Cl0

steenachtige materialen

De isolatie van materialen is in eerste instantie

afhankelijk van ge frequentie en de massa per 2 m •

De gegevens uit [ 9 ] kunnen op basis hiervan in drie groepen

worden verdeeld, n.1. lichte homogene cOI1.structies (minder dan

ca. 150 kg/m~, zwaardere homogene constructies en spouwconstructies. , '.

Voor deze drie groepen resulteren de volgende formu1es als func­

tie van het produkt quentie-massa per m2

: (kHz.kg/m2), waarbij

v~~r de spouwconstructie de gezamenlijke massa van de spouw­

bladen is aangehouden.

fm in kHz. kg/m2

enke1voud constructie

2 m ~ 150 kg/m :

fm <15:R 16,6 19 (fm) + 14,3

15 < fm< 62:R 5 19Cfm) +.128

fm > 62:R = 30 Ig(50+fm) - 24,5

2 m > 150 kg/m:

fm < 40:R ::::

40 < hi < 100 :R

fm >100,:R

20

16,6 19 (fm) + 13

11,6 19Um) 21 't +

- 20 Ig (10- 3 -1 + fm )

16,6 19(fm) + 14,3

11,6 19(fm) + 21

+5

fm .5. 20:R

fm < 75 :R·

fm > 75 :.R . -4-1

-251g (8.10 +fm ) -3,5

(C5)

De iso1atie volgens deze formules is in figuur C4 weergegeven.

Page 68: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad

R

, I I

, I

I

I , , ,

5 10 zo 40 80 160 315 630 1250 frn(kHz kg/;nZ) .,...

FIGUUR G4: Geluidisolatie steenacht homogene en spouwconstructies in octaafbanJen.

Page 69: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

C.2.6

blad el2

lichte borstweringen

De constructies van lichte borstweringen varieren sterk in uit­

voering, van enkele platen (b.v. hout, glas ) tot stijve sand­

wich - constructies en spouwconstructies. De isolatie blijkt ook

bij in grote lijnen gelijke constructies vrij sterk te kunnen ver­

schil1en.

Daarnaast speelt nog een rol dat in de praktijk de afmetingen

in het algemeen gering zijn ten opzichte van de afmetingen

bij laboratorium-metingen.

Op basis van de gegevens uit [ 9 ] en enkele aanvullingen v~~r

wat betreft de lichtere en enkelvoudige constructies is geko­

zen v~~r het geven van enkele typerende gestyleerde isolatie­

curven; deze gegevens leenden zich niet v~~r een benadering in

formule-vorm.

Deze typerende isolatiecurven zijn gegeven in taben cl met de

constructieaanduiding en zijn tevens in figuur C5 weergegeven.

TABEL C.l: Geluidisolatie van enkele typen lichte borstweringen.

Globale dikte en Geluidisolatie in octaafbanden

Type 2 met middenfrequentie massa per m

63 125 2.50 500 lk 2k 4k Hz

1. enkele 5-20 mm 2

10 15 20 25 30 30 35 plaat 5-10 kg/m

2. lichte ca. 40 mm 15 20 25 30 30 35 40 sandwich-con- 20 kg/m 2 ca. structie met stijve tU8sen laag

3. als 2 met ca. 40 mm 2

15 22 30 35 40 40 45 een verende ca. 20 kg/m tussenlaag

4. zware ve- 50-100 mm 2

20 25 35 40 45 50 55 rende sand- ca. 35 kg/m wich- canst.

5. als 4 100-150 mm 2 20 30 40 48 55 60 65 zwaarder en ca. 50 kg/m met een meer verende tus-s-enlaag

Page 70: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad C13

7 0

1 I 1 I:ypf. B

I I /' S

i I i

/ i 0 '"

I -,

1 I

L1

"

, i

I I

i

d

6

I I '/ V It,

, /i IL

/ c n . ;

I I

:~ VV ,v 1/1 i 3,

I ~/J i " I ;, 1J ( ,

5

I / V ~A' I I I ~

I I I k"! 1 V

" I " ! ~ V i;

I I /1/1/ /VV1

~,.-i ( 1/ I I ' I -

I I ~ V .. ' -1-" V 1 I I ,

I V I' yi ! I .. 1 ' ! lL i j i

3

I

/ V ) ,

~ I

J V 1',

I I

~ I' '

i I ,

J ( , l/ I I

I ... " V ! ! ,

i i ~V ~ ,

I I i i Vi 1/ I I .1

V~ I i ! ! I I I

I

, i ./ ! , I ,

\

I I I i I

I i

I

1

I i 1 I I 1

31.5 63 125 250 500 1000 2000 4000 8000 Hz

frequentie ...

FIGUURC.5: GeluidisolaUe van lichte borstweringer, .

itl octaafbanden

Page 71: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

c.2.7

\

blad C14

dakconstructies

Gegevens over de geluidisolatie van dakconstructies zijn slechts

zeer bep~rkt beschikbaar. Deze constructies zijn in [ 9 J niet

behandeld.

..

Voor homogene steenachti~e constructies kan de isolatie overeen­

komstig paragraaf C.2.5 worden gekozen. Voor samengestelde con­

structiesvanhellende pannendaken, al dan niet voorzien, van een

plafond, zijn op basis ~an literatuur [ 13, 14 ] en enige interne

gegevens voor enkele globale groepen constructies voorlopige indi­

caties voor de geluidisolatie afgeleid.

Deze gegevens zijn in tabel C2 gegeven en in figuur t6. Aangezien bij dergelijke daken de geluidlekken gedeeltelijk inhe­

rent zijn aan de constructie (dakpannen) is dit effect in deze

gegevens opgenomen. De geluidlekken bij randaansluitingen en te

\ openen delen kan op gelijke wijze als bij andere begrenzingsvlak­

ken via de kierfactor worden verdisconteerd, waarbij als voorlo­

pige indicatie een kierfactor van 10-3 a 10-

4 als gebruikelijk kan

worden aangehouden.

TABEL C.2:Geluidisolatie van enkele samengestelde dakconstructies

(voorlbpige indicatieve gegevens)

Geluidisolatie(dB) in octaafbanden

type, omschrijving met middenfrequentie.

63 125 230 500 lk 2k 4k Hz

l. Pannendak op balken, 10 10 11 12 13 14 15 diverse soorten pannen

2. Pdluleuudk up ualken, 15 20 22 25 28 28 28 dakbeschot vanhouten 2 delen massa 20-40 kg/m

3. Ais 2 met dakbeschot 15 20 25 30 35 35 35 van goed gesloten platen

4 • Als 3 met minimaal 50 mm 15 20 30 35 45 50 55 minerale wol tussen pan-nen en dakbeschot

5. Pannendak, met dakbeschot 20 25 30 35 40 45 50 en gipsplaat of houten plafond, massa 40-80 kg/m

L

6. Ais 5 met 50-100 mm 20 25 40 47 55 60 65 miner:ale wol op plafond I

7 • Plat dak met dakplaat en 30 35 45 50 55 60 65 plafond (gipsplaat o~d) met kiezels.teen, massa ca. 120 kg/m2

Page 72: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

R

70

dB

60

50

40

30

20

10

1

I !

. I ,~

I v ..(0'

,/

·lliJ v

tf i !L

V •

I J I

.., i/

.., ...

l! : ..,

t p4! Vi : vt : '# ./ I r tl I

I .' ."

!LV ,r-;.. -... l«-V ..>r ...

r' • ...

r- r .J; i I-~

~ ~ i

.. IL ''''["T

=ff I

I ,

31,5 63 125 250 500 1000

uentie

6

~ ~

~~

V v

I te-

1/ .;'

,.-

'" ..- 5 1/ '" ..-

..-v"

•• I

-f- - - -- 2.

11

~

2000 4000

blad C15

I

-I

8000 Hz

FIGUUR C. 6 :G e luidisolatie van samengestelde dakconstructies

in octaafbanden.

Page 73: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

C.2.8

blad C16

ventilatievoorzieningen

Ventilatievoorzieningen moetenin eerste instantie kunnen voldoen

aan een gestelde ventilatie-eis(luchthoeveelheid in m3/s). Aan een

gestelde eis kan worden voldaan met een eenvoudige opening of met

een akoestisch gedempte opening.

Ventilatievoorzieningen kunnen derhalve aIleen zinvol op akoestische

kwaliteit (op 10 m2 absorptie genormeerd geluidniveauverschil D ) n

worden gerangschikt bij gelijke luchthoeveelheid. Hiervoor LS een

I h h lh . d k 10-3 3; V .. uc t oevee e1 ge ozen van m s. oorzlenlngen voor een

grotere luchtdoorlaat zullen in eerste instantie evenredig groter

moeten worden gekozen met een evenredig lager niveauverschil:

D . n,elS vereiste luchthoeveelheid ( C6)

Op basis van een beperkte hoeveelheid gegevens Of] zijn Ln tabel C3

ter indicatie karakteristieke waarden opgenomen van de akoestische

kwaliteit van enkele typen ventilatievoorzieningen bij een lucht--3 3 hoeveelheid van 10 m Is.

TABEL C. 3 : Indicatie van het op 10m2 absorptie genormeerd nlveau­

verschil D van enkele ventilatievoorzieningen bij een n -3 3

luchthoeveelheid van 10 .m Is

Indicatie bruto Dn (dB) in octaafbanden met afmetingen middenfrequentie

type (rom2) 63 125 250 500 Ik 2k 4k

1. opening 200 x 5 40 40 40 40 40 40 40

2. ongedempte 200 x 50 37 37 37 37 37 38 39 voorziening (rooster rret gaas)

3. enigzins gedempte 200 x 100 40 36 33 36 45 55 65 voorziening

4. redelijk gedempte 200 x 150 40 37 38 43 51 59 65 voorziening

5. geed gedempte 200 x 250 40 40 44 51 58 65 65 voorziening

Hz

Page 74: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

80

dB

70

60

50

40

30

20

10

blad C 17

I

I I t p~ 1 .

! 5 . / . ' .' / " , . V . /

V If. 1/ / .

/~ . ,

// V " .- i / I

. . / I . . ' / . . / / 1-~ ~ ./

"'"~ !- -- .~ .... ;;;;; ..:: --~ ""'0::::::

. -- - -..... ./ ......... ......... ~ ""

31,S 63 125 250 500 1000 2000 4000 8000 Hz frequent ie ____ •• ~

2 Figuur C.7:Genormeerd niveauverschil (op 10 m absorptie) van

ventilatievoorzieningen bij een luchthoeveelheid van -3 3

10 m /5 in octaafbanden.

Page 75: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad CI8

Indien meetgegevens worden gebruikt van een voorziening met een opge­

geven luchtdoorlaat 0m

dan kan daaruit bij een vereiste luchtdoorlaat

0. het aantal voorzieningen n worden bepaald via: elS

n . elS

o . elS

~ Ret daarbij behorende niveauverschil bedraagt

D . n,els

0m = D + 10 19-n,m 0 eis

(C 7)

(C 8)

In veel gevallen zijn voorzieningen in verschillende lengtematen

leverhaar. Als daarbij de dwarsdoorsnede over de hele lengte constant

is kan op de zelfde wijze de benodigde lengte ten opzichte vande

lengte van de gemeten voorziening worden bepaald, en het bijbehorende

niveauverschil.

Als de meetgegevens geen betrekking hebben op het genormeerd niveau-\

verschil maar op de geluidisolatie, gerefereerd aan een oppervlak

S (bruto-oppervlak, netto-oppervlak of referentieoppervlak) d.an kan m

formule C8 worden. vervangen door:

D n,

= R + 10 19 10 m

+ 10 19 o

m 0. (C 9)

el.S

Page 76: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad Dl

BIJLAGE.D: Referentiespectrum c

Do. Inleiding

Teneinde het genormeerd geluiddrukniveau DnT te kunnen uitdrukken

in een gevelverschil in geluidniveau-A dient te'worden gerefereerd

aan een spectrum voor het geluid buiten. Dit kan een spectrum

zijn v~~r een bepaalde gegeven situatie, het referentiespectrum.

B i j . een aantal typen luidbronnen vertoont in vrij veel situa-

ties (b.v. geluid op relatief geringe afstand van w~gen of spoor-/

wegen) het geluidspectrum vrij geringe variaties.

Ter vereenvoud ingkan in die situaties een gestandaardiseerd

referentiespectrum worden gehanteerd. Typerende spectra en voor­

komende variaties zijn gegeven in [ 3 ] , waarbij o?k de invloed

op het gevelverschil in geluidniveau-A nader is geanalyseerd.

Toepass van een gestandaardiseerd referentiespectrum voor een . . bepaalde geluidbron, ook op meetresultaten van situaties waarin

het geluidspectrum af zal wijken van dit spectrum, biedt daar­

naast een mogelijkheid om de geluidreductie van gevels onderl

op een eendtYidige wi'jze te vergelijken.

Page 77: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad D2

D.2 Toepassing referentiespectrum

Op basis van een opgegeven referentiespectrum kan het geluidspectrum

in het vertrek worden berekend door het referentiespectrum per octaaf­

band te verminderen met het genormeerd niveauverschil per octaaf­

band.

Het verschil tussen het geluidniveau-A van het referentiespectrum en van

dit binnenspectrum is het gevelverschil in geluidniveau-A voor het

reeet:,t;nttespectrum.

Aangezien het hier om een verschil gaat is het feitelijke geluidniveau-A

voor het referentiespectrum niet van belang •

. Noot: Een vereenvoudiging van de berekening kan dan ook worden ver­

kregen als het referentiespectrum zodanig wordt gegeven dat het

geluidniveau-A juist 0 dB(A) is.

In tabel DI is een uitgewerkt voorbeeld van de berekening gegeven.

Tabel D.I: Voorbeeld van de berekening van het gevelverschil in ge!luid­

niyeau-A, D· . nT,Aref~

octaafbanden met middenfrequentie in Hz geluidniveau-A

'63 125 250 500 lk 2k 4k

(1) referentiespectrum 50 49 36 37 40 36 2S

(2) A-weging -26 -]6 -9 -3 0 +1 +1

referentiespectrum A-gewogen (3) =(1)+(2) 24 33 27 34 40 37 26 43

(4) ,

DnT 12 14 18 22 24 23 26

binnenspectrum, A-gewogen 12 19 9 12 16 14 0 23

(5) -0)-(4)

I). . 20 nTtAref

(6) = (3) - (5)

Page 78: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad D3

A~weging van een geluidspectrum is feitelijk aIleen correct mogelijk

door het gehele spectrum via een continu A-filter te filteren. Een

discrete berekening in octaafbanden Cof tertsbanden) is daarvan een

benadering.

Ten behoeve van de eenvoud en eenduidigheid wordt aanbevolen de in

tabel D2 aangegeven waarden voor de A-weging in octaafbanden aan te

houden en tevens v~~r het referentiespectrum ook van het berekende

geluidniveau-A uit te gaan in plaats van een eventueel ook gegeven

direct gemeten geluidniveau-A.

Noot: Door deze benadering van de feitelijke waarde van het geluid­

niveau-A kunnen kleine verschillen optreden in een opgegeven

A-gewogen referentiespectrum van een bepaald geluid, afhanke­

lijk of dit op voornoemde octaafbandweging is gebaseerd of uit

een A-gewogen tertsbandspectrum is samengesteld.

Page 79: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

bfad D4

D.3 Ret standaard-referentiespectrum

Ret A-gewogen standaard-referentiespectrum is in

tabel D2 gegeven v~~r een/aantal geluidbronnen, zodanig dat

het bijbehorende geluidniveau-A 0 dB is. Deze zijn gebaseerd

op de gegevens uit [3].

Bij toepassing behoeft daardoor geen A-weging meer te worden

gebruikt, zodat debewerkingen volgen? tabel D1 zich beperken

tot de s 5 en de optelling van dat spectrum tot het'

geluidniveau-A.

Tabel 02: Standaard-referentiespectrum in oetaafbanden

v~~r wegverkeersgeluid, railverkeersgeluid en lucht­

verkeersgeluid.

Geluid soort Octaafbanden met middenfrequentie in Hz

63 125 250 500 lk 2k 4k

wegverkeer -26 -14 -10 -6 -4,5 -7 -14

railverkeer -31 -27 -17 -9 -4 -4 -12

luchtverkeer -33 -21 -11 -7 -4,5 -6 -12

I'

Page 80: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad E 1

BIJLAGE E: Rekenvoorbeelden

&1. Voorbeeld van berekende maatregelen

Voor een flatgebouw moe ten geluidwerende maatregelen worden geadviseerd

teneinde voor wegverkeersgeluid een gevelverschil in geluidniveau-A te

bereiken van tenminste 30 dB(A).

Ret aanzicht van de bestaande gevel en de plattegrond van het slaapvertrek,

gelegen aan een galerij met gesloten balustrade, zijn gegeven infiguur EI.

De toegepaste beglazing is 4 . en 2.7 mm (klapraam) met een houten kozijn.

'De naden zijn op normale wijze afgewerkt; bij de te openen ramen is geen

toehtstrip toegepast.

De borstwering bestaat uit een spouweonstructie van liehtbeton (9 em) en

baksteen (10 em).

Ten aanzien van de ventilatiemogelijkheden na het verbeteren van de gevel is

geeist dat de helft van de vereiste hoeveelheid moet kunnen worden geventi-

leerd zonder overschrijding van de gestelde eis aan de geluidreductie.

Uitgaande

12~6 10-3

2 van het vloeroppervlak van 12,6 m is een luchthoeveelheid van 3/ . m s'. vere1.st.

In tabel El a is het rekenresultaat gegeven voor debestaande situatie met

gesloten gevel. Als het klapraam zover wordt geopend dat aan de heHt van

de vereiste luchthoeveelheid'kan worden'voldaan resulteert een waarde van

D = 24 dB(A) (in gesloten toestand is ditook D T A = 24 dB(A); zie nTAv n , v tabel EI)

Door het toepassen van een goede naad- en kierafdiehting is net niet aan

de eis te voldoen (DnTAv resp. 30 en 28 dB(A) bij gesloten en geventileerde

gevel). In tabel El b is het resultaat gegeven van een berekening waarbij naast

een redelijk naad- en kierafdiehting, de beglazing is vervangen door enkel

glas met een dikte van 8 mm en een geluidgedempte ventilatievoorziening van

voldoende luchteapaciteit in de gevel is aangebracht. Bij deze.berekening

zijn voor de ventilatievoorziening meetgegevens toegepast van de fabrikant

(ide tabel El b).

Ret gevelverschil in geluidniveau-A voor wegverkeersgeluid bedraagt ?ij deze

geveluitvoering juist 30 dB(A) in geventileerde toestand en 31 dB(A) in ge-

sloten toestand. Zonder de nauwkeurigheid van de berekeningen in beschouwing

te nemen, wordt hiermee net aan de gestelde eis voldaan. Een nog zorgvuldiger

kier- en naadqichtingkan in dit geval nog 1 dB(A) winst opleveren (zie tabel El b).

Page 81: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad E2

gevelaanzieht

I I r ,

,s 115

110

maten in em

plattegrond

galerij

slaapkamer

ltso

I I

t 'J..80 , I

Figuur &1: Gevelaanzieht en plattegrond van voorbeeld EI.

Page 82: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

GEVEL GELUIDREDUCTIE-BEREKENING

PROJECT ~ SLAAPKAMER FLAT

GEVELOPP: 7.3 M~2 VOLUME: 32.5 M~3 C(G) -1 REFERENTIE-BRONSPECTRUM: WEGVERKEER (=R)

TYPE, OPPERVLAK EN ISOLATIE GEVEL-ELEMENTEN (OCTAVEN/A-GEWOGEN) ELEMENT OPP 63 125 250 500 1000 2000 4000 lSTN-SP 300 KG/H2 3.9 35 39 43 SO 56 62 66

48 2GLAS-E 4MM 3.1 15 19 23 26 30 32 . 28

26 3GLAS-E 2.7 MJ>I .3 13 17 21 24 28 31 29

24

RESULTATEN ========:1'11=

FREQ(HZ) 63 125 250 500 1000 2000 4000

R-VLAK (K=O) 18 22 26 30 33 36 31

D(NT) ,K=TYPE 0 19 23 27 30 34 36 32 IGE,DNTW,DNTAR -18 34( - ) 30

D(NT) ,K=TYPE 1 19 23 26 30 33 35 31 IGE,DNTW,DNTAR -18 33( - ) 30

D(NT),K=TYPE 3 18 21 25 28 31 25 27 IGE,DNTW,DNTAR -25 29(-8 ) 27

D{NT),K=TYPE 5 17 20 24 26 28 22 24 IGE,DNTW,DNTAR -28 26(-8 ) 24

a

GEVEL GELUIDREDUCTIE-BEREKENING

PROJECT: SLAAPKAMER FLAT

GEVELOPP: 7.3 H~2 VOLUME: 32.5 M~3 C(G) -1 REFERENTIE-BRONSPECTRUM: WEGVERKEER. (-R)

TYPE, OPPERVLAK EN F:LEMENT

ISOLATIE GEVEL-ELEMENTEN (OCTAVEN/A-GEWOGEN) opp 63 125 250 500 1000 2000 4000 3.9 35 39 43 50 56 62 66

48 ISTN-SP 300 KG/M2

2GLAS-E 8 MM

3GLAS-E 8 MM

4DN/OCT

RESULTATEN a=====;::r;:::===

FREQ(HZ) 63

R-VLAK (K=O) 22

D(NT),K=TYPE 0 23 IGE,DNTW,DNTAR -18

D(NT),K=TYPE 1 22 IGE , DNTW ,DNTAR -19

D(NT). K=TYPE 3 20 IGE • DNTW ,DNTAR -25

D(NT),K=TYPE 2 22 IGE,DNTW,DNTAR -20

b

2.9 19 23 26 30 32 28 38 29

.3 19 23 26 30 32 28 38 29

.2 32 29 30 37 46 51 55 37

125 250 500 1000 2000 4000

24 26 31 35 31 41

25 27 3Z 36 32 42 34(-6 ) 31

24 27 32 36 31 38 33(-6 ) 31

23 25 29 32 25 28 29(-8 ) 28

24 26 31 34 30 33 32(-6 ) 30

Tabel El Berekeningsresultaten voorbeeld EI

a. bestaand b. verbeterd

Page 83: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

blad E4

E.2 Voorbeeld van een ontwerpbeoordeling

Voor nieuw te bouwen eengezinswoningen ~n de nabijheid van een vliegveld

isals eis gesteld dat het gevelverschil in geluidniveau-A tenminste

D 1 = 35 dB(A) is. nT,A

Van een onder het dak gelegen slaapkamer van een hoekwoning is de platte­

grond en het aanzicht vari de gevels gegeven in figuur E2, tesamen met ge-'

gevens over de constructie.

Het platte dak bestaat uit 10 cm beton. De ventilatie-eis voor deze kamer

bedraagt 15.10-3 m3/s.

In tabel E2 is het resultaat van de berekeningen gegeven. Voor een gesloten

gevel resulteert DnT,Al = 31 dB(A), hetgeen voornamelijk wordt bepaald door

de thermische beglazing in de voorgevel. Door hiervoor in de plaats dubbel glas

met een grotere spouw toe te passen kan in principe van de eis worden voldaan.

In tabel E3 is het resultaat gegeven bij toepassing van de combinatie 8-80-6

~n de voorgevel, hetgeen resulteert in D T Al = 35 dB(A). Als in deze voor-n , .

gevel over de breedte van de vaste beglazing een suskast wordt toegepast, kan

daarmee in ca. 2/3 van de ,ventilatiebehoefte worden voorzien.

Bij toepassing van een suskast met een genormeerd niveauverschil voor het

luchtverkeersspectrum van .. ~a. 38 dB(A) bij een luchthoeveelheidvan 10'10-3m3/s

zal het geluidniveau in het v.ertrek niet nieer dan 1 a 2 dB(A) toenemen.

Bij een zelfde luchthoeveelheid zonder een geluidgedempte voorziening neemt het'

geluidniveau 5 dB(A) toe.

Page 84: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

~8s

t

plattegrond

30

slaapkamer ~ 11f.5

00

310 I I ) )

maten in em

blad E5

voorgevel zijgevel

4- D d

c-

, , I I , I -I- , I

lOt:> 'LIO 300 , i

·t)el BS

cortstructiegegeyens

a. thermisch glas: 6-12-4 (mm)

b. 'enkel glas: 8 mm

c. spouwconstructie: 2 x 2 mm staal, 110 mm spouw

met minerale wol

d. 2 x steens spouwconstructie

Figuur E2: Plattegrond, gevelaanzieht en constructiegegevens van

voorbeeld E2.

n

110

90

Page 85: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

GEVEL GELUIDREOUCTIE-BEREKENING GEVEL GELUIDREDUCTIE~BEREKENING .................................. . __ ..... _ ............••........ /

PROJECT : SLAAPKAMER HOEKWONING PROJECT : SLAAPKAMER HOEKWONING VLAK 1 ; C(L): 0 VLAK 2 ; C(L}: a

CEVELOPP: 7.9 W2 VOLUME: 38.0 M"3 GEVF.LOPP: r2.4 MA2 VOt:.Ul1E : 38.0 MA3 C(G) : 0 C(G) 0 REFERENTIE-BRONSPECTRUM: LUCHTVERKEER (-R) REFERENTIE-BRONSPECTRUM: LUCHTVERKEER (-R)

TYPE, OPPERVLAK EN ISOLATIE GEVEL-ELEMENTEN (OCTAVEN/A-GEWOGEN) TYPE, OPPERVLAK EN ISOLATIE GEVEL-ELEMENTEN (OCTAVEN/A-GEWOGEN) ELEMENT opp 63 125 250 500 1000 2000 4000 ELEMENT opp 63 125 250 500 1000 2000 4000 IGLAS-n 6' 12 4 5.1 19 22 21 29 37 37 37 ISTN-SP 380 1<G/112 11.2 37 40 45 52 58 63 67

30 53 2GLAS-E 811M .3 19 23 26 30 32 28 38 2GLAS-D 6 12 4 1.2 19 22 21 29 37 37 37

30 30 3BRSTWG TYPE 4 2.5 20 25 35 40 4'5 50 55

40 RESULTATEN ..........

RESULTATEN .•........ FREQ(HZ) 63 125 250 500 1000 2000 4000

FREQ(HZ) 63 125 250 500 1000 2000 4000 R-VLAK (1<-0) 29 32 31 39 47 47 47

R-VLAK (K-O) 19 23 23 31 38 37 39 D(NT) ,K"TYPE 0 29 32 31 39 47 47 47 IGE,DNTW,DNTAR -9 ~3( - ) 40

D(NT) ,K-TYPE 0 21 25 25 33 40 39 41 IGE,DNTW,DNTAR -15 36( ~ ) 34 D( NT) ,K"TYPE 1 28 31 31 38 42 38 38

ICE, rlNTW ,DNTAR -12 39( - ) 38 D(NT),K-TYPE 1 21 25 25 33 39 37 38 IGE ,DNTW ,DNTAR .,,16 35{ - ) 33 O{NT) ,K-TYPE 3 23 26 28 32 33 25 28

IGP.,DNTW,DNTAR -25 30( -9 ) 29 DC NT) ,K-TYPE 3 20 24 24 31 34 27 30 IGE,DNTW,DNTAR -23 31( -8 ) 29 D( NT) ,K;'TYPE 1 28 31 31 38 42 38 38

IGE,DNTW,f)NTAR -12 39( - ) 38 D( NT) ,K-n PE 2 21 24 25 32 37 34 34 ICE ,DNTW ,DNTAR -17 34~ - } 32

Tabel E2 Berekeningsresultaat van voorbeeld E2 volgens,ontwerp; zie figuur E2.

Page 86: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

GEVEL GELUIDREDUCTIE-BEREKENING CEVEL GELUIDREDUCTIE-BEREKENING

._----.... -.--------_ ...•.....• .... , .................................... _---PROJECT: SLAAPKAMER HOEKWONING PROJECT: SLAAPKAMER HOEKWONING

VLAK 3 ; C(L}: 0 TOTAAL RESULTAAT MET MEERDERE VLAKKEN

G~VELOPP: 15.0 M"2 VOLUME: 38.0 M"3 AANTAL VLAKKEN: 3

C(G) 0 REFERENTIE-BRONSPF.CTRUM: LUCHTVF.RKEER (-R) CONSTRUCTIE EN SITUAT!E GEGEVENS:

ZIE DETAIL UITVOER PER VLAK

TYPE, OPFERVLAK EN ISOLATIE GEVEL-ELEMENTEN (OCTAVEN/A-GEWOGEN) REFERENTIE-BRONSPECTRUM: ELEMENT OFP 63 125 .250 500 1000 2000 4000 LUCHTVERKEER (-R)

1STN-EN 230 KG/M2 15.0 32 37 41 45 50 55 59 48

RF.SULTATEN ... _-_ ......... RESULTATEN .... _a .... __

FRF.f/(HZ) 63 125 250 500 1000 FREQ(HZ) 63 125 250 500 1000 2000 4000 D(NT},K .. TYPE 0 20 24 ,24 32 39 R-VLAK (K-O) 32 37 41 45 50 55 59 IGE,ONTW,DNTAR -11: 35( - ) 32

O(NT),K-TYPE 0 32 36 41 45 50 54 58 D( NT) ,K .. TYPE 1 20 23 24 31 36 ICF.,ONTW,DNTAR -2 49( - ) 47 IGE.ON'N .ONTAR -18 33( -} 31

D(NT) ,K-TYPE 1 29 33 37 40 42 38 38 D( NT) ,K-TYPE 3 17 20 22 ,26 28 IGE,DNTW,ONTAR -12 41(-7 ) 40 ICE, DNTW ,ONTAR -30 25(-9 ) 24

D( NT) .K-TYPE 3 23 26 29 31 32 24 27 O(NT) ,K"INVOER 20 23 24 31 36

IGE ,ONTW ,ONTAR -26 .29(-9 ) 28 IGE,ONTW,DNTAR -18 33( - ) 31

D(NT) ,K-TYPE 0 ·32 36 41 45 50 54 58 IGE,ONTW,DNTAR -2 4,( - ) 47

.. vervolg

Tabel E2 Berekeningsresultaat vanvoorbeeld E2 volgens ontwerp; Z1e figuur E2.

2000 400.0

38 40

33 33

20 23

32 33

Page 87: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

Z (J1 -i

0 CD :"?: CO ...... r-

<"' • ,~ _.j .~

~ '~:, ~ -., -'-«

,"1 r'; - -q ~,; ... ... -. ! A :.v

CI rll '"0 -I

m

GEVEL GELUIDREDUCTIE-BRREKF.NING ...... _-_ ... __ ... -_ ........ -... PROJECT : SLK DUIIBELGLAS VOOR

VLAK 1 ; C(L): 0 GEVELOPP: 7.9 /01"2 VOLUME: 38.0 W3 C(G) 0 REFERENTIE-BRONSPECTRUM: LUCHTVERKEER (-R)

TYPE, OPPERVLAK EN ISOLATIE GEVEL-ELEMENTEN ELEMENT opp 63 125 250 IGLAS-a 8 80 6 5.1 21 27 34

40 2GLAS-E 8MM .3 19 23 26

30 3BRSTWG TYPE 4 2.5 20 25 35

40

RESULTATEN -------_.-

FREQ(KZ) 63 125 250 500

R-VLAK (K-O) 21 26 34 39

D( NT) ,K-TYPE 0 23 28 36 41 IGE,DNTW,DNTAR -9 43( -6 )

DC NT) ,K-TYPE 1 22 28 35 40 IGE,DNTW ,DNTAR -12 41(-7 )

D( NT) ,K-TYPE 3 21 25 30 34 IGE,DNTW,DNTAR -23 32( -9 )

D( NT) ,K-TYPE 1 22 28 35 40 IGE,DNTW,DNTAR -12 41(-7 )

(OCTAVEN/A-GEWOGEN) 500 1000 2000 4000 42 46 41 48

30 32 28 38

40 45 50 55

1000 2000 4000

43 39 48

45 41 50 41

43 38 40 39

35 27 30 30

43 38 40 39

GEVEL GELUIDREDUCTIE-BEREKENING ---_ .......... _-----.... _---.. .

PROJECT: SLK DUBBELGLAS VOOR TOTAAL RESULTAAT MET MEERDERE VLAKKEN AANTAL VLAKKEN: 3

CONSTRUCT IE EN SITUATIE GEGEVENS: ZIE DETAIL UITVOER PER VLAK

REFERENT IE-BRONSPECTRUM: LUCHTVERKEER (- \l.)

RESULTATEN .... _-----

FREQ(HZ) 63 125 250 500

D(NT),K"TYPE 0 21 26 30 37 IGE,DNTW,DNTAR -12 39( - )

D(NT) ,K-TYPE 1 21 25 29 34 IGE,DNTW,DNTAR -17 35(-6 )

D(NT) ,K-TYPE 3 17 21 24 27 IGE,DNTW.DNTAR -30 25( -9 )

D(NT) ,K-INVOER 21 26 29 35 IGE,DNTW,DNTAR -15 37( -6 )

1000

42 37

38 34

28 24

39 35

Tabel E3 Berekeningsresultaat van de verbeterde voorgevel en van het totaal bij

voorbeeld E2; vergelijk tabel E2.

2000

40

33

20

35

4000

45

34

23

36

a iii Q.

Page 88: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

t. b. v. documentatiesystemen

t.b.v. documentatiesystemen

t.b.v. documentatiesystemen

t.b.v. documentatiesystemen

1. WG-H R-05-02 2. "Geluidreductie door gevels - Rekenmethode" 3. ir. E. Gerretsen 4. Technisch Physische Dienst ITPD-TNO-TH), Stieltjesweg 1, Delft 5. Ministerie van Volksgezondheid en Milieuhygiene 6. Controle geluidsisolatie woningen 8. augustus 1981

16. 65 biz.

1. WG-HR-05-02 2. "Geluidreductie door gevels - Rekenmethode" 3. ir. E. Gerretsen 4. Technisch Physische Dienst (TPD-TNO-TH), Stieltjesweg 1, Delft 5. Ministerie van Volksgezondheid en Milieuhygiene 6. Controle geluidsisolatie woningen 8. augustus 1981

16. 65 biz.

1. WG-HR-05-02 2. "Geluidreductie door gevels Rekenmethode" 3. ir. E. Gerretsen 4. Technisch Physische Dienst (TPD-TNO-THI, Stieltjesweg 1, Delft 5. Ministerie van Volksgezondheid en Milieuhygiene 6. Controle geluidsisolatie woningen 8. augustus 1981

16. 65 biz.

1. WG-HR-05-02 2. "Geluidreductie door gevels - Rekenmethode" 3. ir. E. Gerretsen 4. Technisch Physische Dienst (TPD-TNO-THI, Stieltjesweg 1, Delft 5. Ministerie van Volksgezondheid en Milieuhygiene 6. Controle geluidsisolatie woningen 8. augustus 1981

16. 65 biz.

Page 89: Geluidreductie door gevels : rekenmethode · GELUIDREDUCTIE DOOR GEVELS REKENMETHODE - L AAN adres Stieltjesweg 1 postadres Postbus 155 2600 AD Delft telefoon (015) 569300 telex )(3t!XWx

13. In deze publicatie wordt een rekenmodel beschreven waarmee het genormeerd (geluid~ druk)niveauverschil van gevels in octaafbanden kan worden berekend met betrekking tot diverse bronnen van buitengeluid zoals wegverkeer, railverkeer, luchtverkeer, in­dustrieen, recreatie-inrichtingen. Tevens worden enkele mogelijkheden aangegeven om het rekenresultaat in een getal uit te drukken. In het rekenmodel wordt rekening gehouden met de volgende factoren:

oppervlakte en geluidreducerende eigenschappen van de samenstellende delen van degevel geluidlekken via naden en kieren gevelstructuur (balcons, galerijen e.d.l

- variaties over de gevel in het geluiddrukniveau buiten Voor de meeste bij gevels voorkomende materialen en constructies zijn karakteristieke geluidreducerende eigenschappen, veelal in de vorm van formules, bij het rekenmodel opgenomen. Het rekenmodel is verwerkt in een computerprogramma hetgeen even­eens is gegeven met een korte beschrijving en een beschrijving van de invoergegevens en uitvoer.

13. In deze publicatie wordt een rekenmodel beschreven waarmee het genormeerd (geluid­druklniveauverschil van gevels in octaafbanden kan worden berekend met betrekking tot diverse bronnen van buitengeluid zoals wegverkeer, railverkeer, luchtverkeer, in­dustrieen, recreatie-inrichtingen. Tevens worden enkele mogelijkheden aangegeven om het rekenresultaat in een getal uit te drukken. In het rekenmodel wordt rekening gehouden met de volgende factoren: - oppervlakte en geluidreducerende eigenschappen van de samenstellende delen van

degevel geluidlekken via naden en kieren gevelstructuur (balcons, galerijen e.d.l variaties over de gevel in het geluiddrukniveau buiten

Voor de meeste bij gevels voorkomende materialen en constructies zijn karakteristieke geluidreducerende eigenschappen, veelal in de vorm van formules, bij het rekenmodel opgenomen. Het rekenmodel is verwerkt in een computerprogramma hetgeen even­eens is gegeven met een korte beschrijving en een beschrijving van de invoergegevens en uitvoer.

13. In deze publicatie wordt een rekenmodel beschreven waarmee het genormeerd (geluid­druklniveauverschil van gevels in octaafbanden kan worden berekend met betrekking tot diverse bronnen van buitengeluid zoals wegverkeer, railverkeer, luchtverkeer, in­dustrieen, recreatie-inrichtingen. Tevens worden enkele mogelijkheden aangegeven om het rekenresultaat in een getal uit te drukken. . In het rekenmodel wordt rekening gehouden met de volgende factoren:

oppervlakte en geluidreducerende eigenschappen van de samensteliende delen van degevel

- geluidlekken via naden en kieren - gevelstructuur (balcons, galerijen e.d.)

variaties over de gevel in het geluiddrukniveau buiten Voor de meeste bij gevels voorkomende materialen en constructies zijn karakteristieke geluidreducerende eigenschappen, veelal in de vorm van formules, bij het rekenmodel opgenomen. Het rekenmodel is verwerkt in een computerprogramma hetgeen even­eens is gegeven met een korte beschrijving en een beschrijving van de invoergegevens en uitvoer.

13. In deze publicatie wordt een rekenmodel beschreven waarmee het genormeerd (geluid­druklniveauverschil van gevels in octaafbanden kan worden berekend met betrekking tot diverse bronnen van buitengeluid lOals wegverkeer, railverkeer, luchtverkeer, in­dustrieen, recreatie-inrichtingen. Tevens worden enkele mogelijkheden aangegeven om het rekenresultaat in een getal uit te drukken. In het rekenmodel wordt rekening gehouden met de volgende factoren:

oppervlakte en geluidreducerende eigenschappen van de samenstellende delen van degevel ,geluidlekken via naden en kieren gevelstructuur (balcons, galerijen e.d.l

- variaties over de gevel in het geluiddrukniveau buiten Voor de meeste bij gevels voorkomende materialen en constructies zijn karakteristieke geluidreducerende eigenschappen, veelal in de vorm van formules, bij het rekenmodel opgenomen. Het rekenmodel is verwerkt in een computerprogramma hetgeen even­eens is gegeven met een korte beschrijving en een beschrijving van de invoergegevens en uitvoer.