ge rm an y (280kg) · ym-280d ym-280(led) ym-280d(led) ym-280 ym-280(led)-ds lock signal no yes no...

4
Magnetic Lock (280kg) Specification 11 180 38 Armature Plate Location Pin Anti-magnetic Pin Nut M8X35 Screw washer Rubber Ring Cautions: A. The screw of armature plate should not be fixed too tight. Proper elasticity should be guaranteed for the rubber ring so that the armature plate can adjust itself to the appropriate position. B. Check the jumper's position before connecting. Figure out it represents 12VDC or 24VDC. ! www.yli.cn (unit:mm) Diagram We create security 43 38 180 11 25 500 Srew Hole Wire Hole Mounting Plate 43 250 25 Size(unit:mm) Voltage 12/24VDC 12/24VDC 12/24VDC 12/24VDC Ho ding Force l 280kgx2(600Lbsx2) 280kg(600Lbs) 280kg(600Lbs) 280kgx2(600Lbsx2) Door Single Door Double Door Single Door Double Door Model Current 250Lx48.5Wx25H 500Lx48.5Wx25H 250Lx48.5Wx25H 500Lx48.5Wx25H Door Signal No No 12/24VDC 280kg(600Lbs) Single Door 12V/500mA 24V/250mA 12V/5 24V/2 00mAx2 50mAx2 12V/500mA 24V/250mA 12V/5 24V/2 00mAx2 50mAx2 12V/500mA 24V/250mA 250Lx48.5Wx25H YM-280D YM-280(LED) YM-280D(LED) YM-280 YM-280(LED)-DS Lock Signal No Yes No Yes Yes No No 12/24VDC Double Door 500Lx48.5Wx25H 280kgx2(600Lbsx2) 12V/5 24V/2 00mAx2 50mAx2 YM-280TD(LED) Yes No 12/24VDC Single Door 250Lx48.5Wx25H 12V/500mA 24V/250mA YM-280T(LED) Yes No 280kg(600Lbs) 12/24VDC 280kgx2(600Lbsx2) Double Door 500Lx48.5Wx25H 12V/5 24V/2 00mAx2 50mAx2 YM-280D(LED)-DS Yes NO(B),NC(R) COM(Y) NO(B),NC(R) COM(Y) tested Germany EMC R

Upload: others

Post on 31-Jan-2021

17 views

Category:

Documents


0 download

TRANSCRIPT

  • Magnetic Lock(280kg)

    Specification

    11

    180

    38

    Armature Plate

    Location Pin

    Anti-magnetic Pin

    Nut

    M8X35 Screw

    washer Rubber Ring

    Cautions:

    A. The screw of armature plate should not be fi xed t oo ti ght . Proper elasticity

    sho uld b e gua ran teed for th e rub ber ring so that the armature plate can adjust

    itself to the appropriate position.

    B. Check the jumper's position before connecting. Figure out it represents 12VDC

    or 24VDC.

    !

    www.yli.cn

    (unit:mm)Diagram

    We create security

    43

    38

    180

    11

    25

    500

    Srew Hole

    Wire Hole

    Mounting Plate

    43

    250

    25

    Size(unit:mm) Voltage

    12/24VDC

    12/24VDC

    12/24VDC

    12/24VDC

    Ho ding Forcel

    280kgx2(600Lbsx2)

    280kg(600Lbs)

    280kg(600Lbs)

    280kgx2(600Lbsx2)

    Door

    Single Door

    Double Door

    Single Door

    Double Door

    Model Current

    250Lx48.5Wx25H

    500Lx48.5Wx25H

    250Lx48.5Wx25H

    500Lx48.5Wx25H

    Door Signal

    No

    No

    12/24VDC 280kg(600Lbs) Single Door

    12V/500mA

    24V/250mA

    12V/5

    24V/2

    00mAx2

    50mAx2

    12V/500mA

    24V/250mA

    12V/5

    24V/2

    00mAx2

    50mAx2

    12V/500mA

    24V/250mA250Lx48.5Wx25H

    YM-280D

    YM-280(LED)

    YM-280D(LED)

    YM-280

    YM-280(LED)-DS

    Lock Signal

    No

    Yes

    No

    Yes

    Yes

    No

    No

    12/24VDC Double Door500Lx48.5Wx25H 280kgx2(600Lbsx2)12V/5

    24V/2

    00mAx2

    50mAx2YM-280TD(LED) Yes No

    12/24VDC Single Door250Lx48.5Wx25H12V/500mA

    24V/250mAYM-280T(LED) Yes No280kg(600Lbs)

    12/24VDC 280kgx2(600Lbsx2) Double Door500Lx48.5Wx25H12V/5

    24V/2

    00mAx2

    50mAx2YM-280D(LED)-DS Yes

    NO(B),NC(R)COM(Y)

    NO(B),NC(R)COM(Y)

    testedGermany

    EMCR

  • www.yli.cn We create security

    Installation

    Drill a hole

    Inside: Diameter is 8mm

    Outside: Diameter is16mm

    Door leaf

    Drill holes based on themarked positions.

    Make a combinationbased on the picture.

    Hollow Metal Door Wooden Door Metal Surface Door

    Drill a hole

    Inside: Diameter is 8mm

    Outside: Diameter is 12.7mm

    Inside:Drill a hole

    diameter is 8mm folding

    the plastic straight pin

    36mm

    Steps

    Fold the plate to 90 . Close the door first, then

    place the upper side of

    template on door frame,

    while adjust the left side

    next to the door leaf.

    Template

    Door Frame

    Door leaf

    Template

    Door Frame

    Door leaf

    Template

    Mark screw positions of

    armature plate and magnetic

    lock on door leaf and door

    frame respectively.

    Setpin

    Strike the pin into thearmature plate slightly(to avoid movement).

    Make a combination based

    on the picture(add washer

    accordingly).The rubber ring

    must be added.

    Place the rubber ring

    between armature plate

    and door leaf.

    Allen Key

    Use Allen key to removethe mounting plate fromlock body.

    Rubber ring

    Fix the mounting plate onthe door frame accordingto the holes drilled earlier.

    Use Allen key to screwthe lock body on themounting plate.

    After all the appropriateprocedures, the holdingforce can be maximized.Finally, fix the tamperscrew.

    Screw door

    Wire

    Wire

    Allen Key

    Close the door to testholding force. The anglebetween armature plateand magnetic lock canbe adjusted by addingor reducing washers.

  • www.yli.cn We create security

    Installation Instruction

    Demonstration of UL BracketInstallation

    Demonstration of ZL BracketInstallation

    Demonstration of L BracketInstallation

    Bracket Instal lat ion

    Demonstration of I BracketInstallation

    Different brackets are available according to different types of doors. For example,

    narrow door , frameless glass door and inward opening door.

    L Bracket-For outward opening door

    When the door frame thickness is less than

    42mm, L bracket is needed.

    ZL Bracket-For inward opening door

    For inward opening door, ZL bracket is

    needed.

    U Bracket

    For the frameless glass door. U bracketis needed.

    I Bracket for armature plate

    When the door frame is too thick, I bracket

    is needed.

    Door Leaf

    Frame

    Armature BracketFrameless glass door

    Outswing doorInswing door

    Door Frame

  • www.yli.cn We create security

    Circuit Board Diagram

    Wire Connection

    A.12VDC Input:

    Required power 0.5Amp(Minimum).

    Connect the positive(+)lead from a 12VDC

    power source to V +.

    Connect the ground(-)lead from a 12VDC

    power source to V -.

    Check jumper for 12 VDC operation.

    B.24VDC Input:

    Required power 0.25Amp(Minimum).

    Connect the positive(+)lead from a 24VDC

    power source to V +.

    Connect the ground(-)lead from a 24VDC

    power source to V -.

    Check jumper for 24 VDC operation.

    YM-280,YM-280DYM-280(LED),YM-280(LED)-DS,

    YM-280D(LED),YM-280D(LED)-DS

    Time delay setting

    YM-280T(LED),YM-280TD(LED)

    Ò³Ãæ 1Ò³Ãæ 2Ò³Ãæ 3Ò³Ãæ 4