ge multilin gemultilin

19
MIFII DIGITAL FEEDER PROTECTION A Cost Effective Protection Solution for Overcurrent Protection at Any Voltage Level GE Multilin www.gemultilin.c om

Upload: alohilani-matthew

Post on 05-Jan-2016

132 views

Category:

Documents


2 download

DESCRIPTION

MIFII DIGITAL FEEDER PROTECTION A Cost Effective Protection Solution for Overcurrent Protection at Any Voltage Level. GE Multilin www.gemultilin.com. BLOCK DIAGRAM. MIFII Protection and Control characteristics:. Combines Overcurrent Protection and Multiple-shot Reclosing in One Compact Relay. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: GE Multilin gemultilin

MIFII DIGITAL FEEDER PROTECTION

A Cost Effective Protection Solution for Overcurrent Protection at Any Voltage Level

GE Multilinwww.gemultilin.co

m

Page 2: GE Multilin gemultilin

2

GE Multilinwww.gemultilin.co

m

MIFII Protection and Control characteristics:

BLOCK DIAGRAM

Combines Overcurrent Protection and Multiple-shot Reclosing in One Compact Relay

Combines Overcurrent Protection and Multiple-shot Reclosing in One Compact Relay

Page 3: GE Multilin gemultilin

GE Multilinwww.gemultilin.co

m

REPLACE ALL THIS………………………………………….……….WITH MIFII

+

MIFII – OVERCURRENT PROTECTION

Page 4: GE Multilin gemultilin

4

GE Multilinwww.gemultilin.co

m

The MIFII can be used for:

• Applicable to Electric Utilities and Industrial Plants

• 50 or 60 Hz Systems• Main Protection for Medium and Low

Voltage Feeders• Main Protection for Power Transformers

(less than 10MVA)• Core Balance Differential Protection for

Motors• Backup Protection for Power Transformers

(for any power level)• Backup Protection for Generators• Backup Protection for Transmission Lines• Backup Protection for Substation Busbars• Thermal Image Protection/Supervision for

Cables, Power Transformers, Grounding Resistors and Generation Elements

APPLICATIONS

Page 5: GE Multilin gemultilin

GE Multilinwww.gemultilin.co

m

TYPICAL WIRING

Page 6: GE Multilin gemultilin

6

GE Multilinwww.gemultilin.co

m

MIFII Protective Functions include:

• Phase Time Overcurrent (51P)0.1 – 2.4 A (1Amp model)0.5 – 12A (5Amp model)

• Ground Time Overcurrent (51G)0.1 – 2.4 A (1Amp model)0.5 – 12A (5Amp model)

• Phase Inst Overcurrent (50P-1, 50P-2) 0.1 to 30.0 (1 Amp model)

0.5 to 150.0 (5 Amp model)

• Ground Inst Overcurrent (50G-1, 50G-2)0.1 to 30.0 (1 Amp model)0.5 to 150.0 (5 Amp model)

• Sensitive and Very Sensitive Ground Overcurrent Models

0.005-0.12 A or 0.002-0.048A (1 Amp model)

• Selectable Time Overcurrent Curves (Definite Time, ANSI, IAC or IEC)

PROTECTION AND CONTROL

Page 7: GE Multilin gemultilin

7

GE Multilinwww.gemultilin.co

m

• Preconfigured Overcurrent Curves, Definite Time Curve &One User Configurable Overcurrent Curve (FlexCurve)

• Selectable ANSI, IAC or IEC curve option when ordering

• IAC Option

IAC Extremely Inverse

IAC Very Inverse

IAC Inverse

IAC Inverse Long

IAC Inverse Short

• ANSI Option

Extremely Inverse

Very Inverse

Inverse

• IEC Option

Inverse (IEC Curve A)

Very Inverse (IEC Curve B)

Extremely Inverse (IEC Curve C)

MIFII Time Current Curve Options:

PROTECTION AND CONTROL

Page 8: GE Multilin gemultilin

8

GE Multilinwww.gemultilin.co

m

• Thermal Image Protection (49)

• Cold Load Pickup (available in Option 2 models)(Phase IOC & TOC multipliers)

• Breaker Failure to Open (available in Option 2 models)

• I2 Counter with Alarm for Breaker Health Monitoring (available in Option 2 models)

MIFII Protective Functions include:

PROTECTION AND CONTROL

Page 9: GE Multilin gemultilin

9

GE Multilinwww.gemultilin.co

m

• Logic Configuration (available in Option 2 models)

•4 logic groupings (Logic 1, Logic 2, Logic 3 and Logic 4)

MIFII Programmable Logic & I/O Features

PROTECTION AND CONTROL

Page 10: GE Multilin gemultilin

10

GE Multilinwww.gemultilin.co

m

• Programmable Inputs and Outputs (available in Option 1 & 2 models)

MIFII Programmable Inputs, Outputs & LEDs:

PROTECTION AND CONTROL

Page 11: GE Multilin gemultilin

11

GE Multilinwww.gemultilin.co

m

• Four Shot Recloser for Three-Pole Application (available in Option R models)

• Select protective functions to be active before and after each reclose shot

• Selectable shot dead times

• Selectable reset time and incomplete sequence time

• 2 Setting groups

• Manual Open/Close Breaker

• Security• Access password for setting

changes

• Local access password

MIFII Control Features:

PROTECTION AND CONTROL

Page 12: GE Multilin gemultilin

12

GE Multilinwww.gemultilin.co

m

• Phase and ground currents metering(Ia, Ib, Ic, Ig) on front display in primary or secondary values

• Thermal image metering

• 32 event recorder with analog and pickup/trip details (available in Option 1 and Option 2 models)

MIFII Metering & Monitoring Features:

METERING & MONITORING

Page 13: GE Multilin gemultilin

13

GE Multilinwww.gemultilin.co

m

• One oscillography record (available in Option 1 and Option 2 models)

• 8 samples per cycle with a length of 24 cycles (including 2 prefault cycles)

• Instantaneous values Ia, Ib, Ic, Ig

• Pickups

• Trip inhibition by digital input

• Trips

• Ready (protection in service)

• Auxiliary digital outputs

• Digital inputs

• Breaker 52A, Breaker 52B, (digital input status)

• Breaker Closed (OPTION 2 models)

• Breaker opening failure (OPTION 2 models)

• I2 alarm (OPTION 2 models)

• Cold load pickup (OPTION 2 models)

• Group 2 selection by digital input

• EEPROM failure

• Default settings/User settings

MIFII Metering & Monitoring Features:

METERING & MONITORING

Page 14: GE Multilin gemultilin

14

GE Multilinwww.gemultilin.co

m

DISPLAY & LEDS

KEYPAD

Text 2x16 display 6 LEDs with customizable label panel (4

programmable with Option 1 and Option 2 models)

Able to Read Metering Display in Direct Sunlight

ESC/RESET key UP/DOWN keys for easy navigation ENTER function Menu key

FRONT PORT

Electrically isolated front RS232 communication port for programming, data retrieval and firmware update

HARDWARE

DRAWOUT CONSTRUCTION

Entire MIFII unit is removable from case

Page 15: GE Multilin gemultilin

15

GE Multilinwww.gemultilin.co

m

Compact Design in a Modular Package for Easy MaintenanceCompact Design in a Modular Package for Easy Maintenance

DIMENSIONSOPTIONAL DEPTH REDUCING COLLAR (B1315P1)

Page 16: GE Multilin gemultilin

16

GE Multilinwww.gemultilin.co

m

Logic

MeteringOscillography

MIIPC Software provides the following functions:

Powerful Configuration Tool That Get the MIFII up and Running in Minutes

Powerful Configuration Tool That Get the MIFII up and Running in Minutes

Settings

EnerVista MII Setup Software (no-charge)

Page 17: GE Multilin gemultilin

17

GE Multilinwww.gemultilin.co

m

• A front mounted RS232 and a rear RS485 port allow easy user interface via a PC

• Modbus RTU protocol is used for all ports

• The relay supports baud rates from 300 to 19200 bps. Settable Modbus Slave address.

• Use optional MULTINET-FE to get Modbus TCP/IP connection (10MBps)

• Compatible with Viewpoint Monitoring Software

COMMUNICATIONS

Page 18: GE Multilin gemultilin

18

GE Multilinwww.gemultilin.co

m

***

OPTION TO GET HARSH CONFORMAL COATING – H (last letter of model number)

MIFII - ORDER CODE

AC/DC Power Supply

Page 19: GE Multilin gemultilin

19

GE Multilinwww.gemultilin.co

m

• B1315P1 Depth reducing collar (reduces the mounting depth by 2.45 inches)

• B1343P1 S1/S2 case adapting collar for retrofit installations

MIFII - ACCESSORIES

OPTIONAL S1/S2 CASE ADAPTER COLLAR

(B1343P1)