gasf monthly safety report dec- 2014
TRANSCRIPT
GASF – Site Safety Statistics
Sl. No Indicators
Category / Month FTM
Overall From Dec -
14
1 Man hours Worked
Prosperous Emp(Include OT) 5182 5182
Contract Emp 1344 1344
Total for Dec ’14 6526 6526
2 No. of Reportable Incidents Dec ’14 0 0
4 Man days Lost Dec ’14 0 0
5 No. of Non Reportable Incident Dec ’14 0 0
6 No. of First Aid Cases Dec ’14 0 0
7 No. of Near Miss Incidents Dec ’14 – USC + USA 1 1
Sl. No
Indicators Category / Month
FTMOverall
From Dec -14
8 Lost Time injury frequency Rate Dec ’14 0 0
9 Lost Time Injury Severity Rate Dec ’14 0 0
10 Environmental Incident Dec ’14 0 0
11 No. of Dangerous Occurrence Incidents Dec ’14 0 0
12 HSE Internal Audit Carried Out Dec ’14 1 1
13 Employees Externally Trained Dec ’14 0 0
GASF – Site Safety Statistics
Sl.No
Indicators FTMOverall
From Dec -14
14Safety
Training Internally
Induction Training – No of Workmen attended 10 Persons 10 Persons
Refresh Training – No of Workmen attended. 0 Persons 0 Persons
15 Safety Tool box Talk – No. of Workmen attended 33 Persons 33 persons
16 Emergency Response Exercise (Mock Drill) 0 0
17 Safety Meeting 1 1
18 HSE Award to Employees 0 0
GASF – Site Safety Statistics
S. No Job Description Status Remarks
1 Unwanted material to be removed from inside the rest room Closed
2 Exhaust fan not working in bathroom and Pantry room Open MPR No: 033543Raised Date: 14.12.2014
3 1 no Toilet cabin not enough for 40 employees, need another one toilet cabin Open MPR No: 033543
Raised Date: 14.12.2014
4 While concreting in RCC, one of the our contract employee not wear helmet and gumboot. Closed
Work was stopped and toolbox talk was given to the victim about seriousness of issue and usage of PPEs
5 All unwanted scrap to be collected and stored in designated place Closed
6 In suction line heavy diesel leakage in generator, leak to be arrested or suction pipe to be replaced by new one Closed
7 Signage board not available in chemical storage area Closed
Internal Safety Observation (USC + USA)
S. No Job Description Status Remarks
8 First aid box not available in site Closed
9 Every 3 day toilet tank got overfilled and land was polluted by this water , tank to be procured (1000 Gal ) Closed
10 Drinking water facility to be arranged in site . water Cooler to be procured Open MPR No: 33501
Raised Date : 01.10.2014
11 One of the our contract worker using grinding machine without safety guard. (USA) Closed Safety Guard was fixed
12 Electrical cable laid on the walkway, cable should be properly routed away from the walkway Closed
13 Food waste bin to be provided in rest room area Closed
Internal Safety Observation (USC + USA)
POWER TOOLSInspection carried on 17.12.2014
SL. NO EQUIPMENT DESCRIPTION MAKE TESTED ON REMARKS
2 AG-7 Grinding PGM-035 , 230V MAKITA 17.12.2014 Working Normal
3 AG-7 Grinding DG 851, 230V KEYANG 17.12.2014 Working Normal
4 Drilling Machine HP 1640 ,230V MAKITA 17.12.2014 Working Normal
5 Drilling Machine HP 1640 ,230V MAKITA 17.12.2014 Working Normal
6 Jip saw Machine PJM -006 MAKITA 17.12.2014 Working Normal
7 Chargeable screw machine , BL 1830 MAKITA 17.12.2014 Working Normal
8 Recipro Saw Machine MAKITA 17.12.2014 Working Normal
9 Circular cutting machine MAKITA 17.12.2014 Working Normal
Fire Extinguisher Visual Inspection Carried out on 22.12.2014
FX. no Capacity (Kg) Next Inspection Date REMARKS Inspected by
Dcp/01 6 15.12.2014 Overall condition is Good Prasath.B
Dcp/02 6 15.12.2014 Overall condition is Good Prasath.B
Dcp/03 5 15.12.2014 Overall condition is Good Prasath.B
Dcp/04 6 15.12.2014 Overall condition is Good Prasath.B
Co2/01 9 15.12.2014 Overall condition is Good Prasath.B
1. Date & Time Observed 20.12.2014 at 2.30 PM.
2.Location observed Office Building Area (GASF Site)
3. Description of the observationElectrical cable is crossing on the walkway at the ground level, one of the our worker walked the path, he had tripped by cable . But some how he managed from fall and no harm happened to him.
4. Root Cause
Cable laid on the walkway
5. Corrective & Permanent Action Cable should be Properly routed away from the walk way
6. Reported By Prasath.B
7. Dept: Safety
Near Miss Report: 1