gas turbine flowmeter - tms k · 2009-02-02 · 당사에서 생산되는 tgfe(turbine gas...

25
GAS TURBINE FLOWMETER MANUAL TGFE & FDC-4000 TMS KOREA CO., LTD.

Upload: others

Post on 17-Mar-2020

25 views

Category:

Documents


2 download

TRANSCRIPT

  • GAS TURBINE FLOWMETER

    MANUAL

    TGFE & FDC-4000

    TMS KOREA CO., LTD.

  • - I -

    CONTENTS

    TGFE Series Gas Turbine Flowmeter

    1. 제품개요 ······················································································································1

    1.1 제품의 특징 ························································································································1

    1.2 적용기체 ······························································································································1

    2. 주요사양 ······················································································································2

    2.1 제품 사양 ····························································································································2

    2.2 내부구조 ······························································································································3

    2.3 제품치수 ······························································································································3

    2.4 유량범위 ······························································································································4

    2.5 측정정밀도 ··························································································································5

    3. 사용상의 주의사항 ····································································································5

    3.1 제품명판 확인 ····················································································································5

    3.2 운반에 관한 주의사항 ······································································································6

    3.3 보관에 관한 주의사항 ······································································································6

    3.4 설치장소의 주의사항 ········································································································6

    4. 주문시 주의 사항 ······································································································7

    4.1 합리적인 유량측정 범위내의 유량계 선택 ··································································7

    4.2 주문시 매개변수 자료 협조 ····························································································7

    5. 기타 주의사항 및 보증기간 ····················································································8

  • - I -

    FDC-4000 FLOW TOTALIZER

    1. 제품소개(Introduction) 및 특징(Feature) ···························································1

    2. 적산계 코드 ················································································································1

    3. LCD 기본화면 구성 ································································································2

    4. 외부 결선법 및 외부결선 치수 ··············································································2

    4.1 출력 단자 ·····························································································································2

    4.2 매개변수 조작 Key 단자 ·································································································3

    5. FLOW - SET MENU ·······························································································4

    5.1 Set Frequency Band ·······································································································4

    5.2 K-Factor count ················································································································5

    5.3 Set - Temperature ··········································································································5

    5.4 Set - Z data ·····················································································································5

    6. INTERFACE - SET MENU ·····················································································6

    6.1 High - Flow ······················································································································6

    6.2 Low - Flow ·······················································································································6

    6.3 20mA - Data ····················································································································6

    6.4 4mA - Data ·······················································································································6

    6.5 Qo - Frequency ··············································································································6

    6.6 Qs - Frequency ···············································································································6

    6.7 Cal - Pressure ·················································································································6

    6.8 Pressure - Data ···············································································································7

    6.9 485 - ID ·····························································································································7

  • - II -

    7. 485 Communication Protocol ············································································7

    7.1 Data format ·······················································································································7

    7.2 Query Command Spec ··································································································7

    7.2.1 Query code spec ·····································································································8

    7.3 Response Spec ················································································································8

    7.3.1 Query code spec ·········································································································8

    8. 각 그룹 메뉴 및 파라미터 SETTING 방법 ·························································9

    8.1 디스플레이 모드의 종류 및 모드 전환 ······································································9

    8.2 파라미터 설정의 예 ········································································································10

    8.2.1 FLOW SETTING MENU의 진입 ···········································································10

    8.2.2 K-Factor setting menu ························································································11

  • TMS KOREA CO., LTD.

    TEL : +82-53-854-7361 A/S Center : +82-53-854-7363 Homepage : http://www.tms-k.com

    - 1 -

    천연가스(Natural gas) 공기(Air)도시가스(Town gas) 아세틸렌(Acetylene)메탄(Methane) 헬륨(Helium)에탄(Ethane) 이산화탄소(Carbon dioxide(Dry))프로판(Propane) 질소(Nitrogen)부탄(Butane) 수소(Hydrogen)

    TGFE계열 기체 터빈 유량계

    1. 제품개요

    당사에서 생산되는 TGFE(Turbine Gas Flowmeter Electronic) 기체터빈 유량계는 여러 장의 날개를

    붙인 회전익(翼)을 배관 내에 설치하고 기체를 통과 시키면 유속에 비례하여 회전익이 회전을 하게 된

    다. 회전익에 자석을 설치하고 배관 외부에 FLOW SENSOR를 설치하면 회전익이 회전을 하면서 전기적

    신호(PULSE)를 발생 하게 된다. 이 신호를 주파수(Hz)를 COUNT하여 배관을 통과 하는 기체의 유량을

    측정 하는 원리이다.

    특히 TGFE에는 온도, 압력센서와 연동(連動)하여 최신 전자(Electronics)기술을 구사하는 멀티(Multi)기

    능의 적산계(Controller)를 탑재하고 있다.

    설계 규격 (ISO 9951:1993, DIN EN 12261:2002, OIML, KS A 0515:2005 )

    1.1 제품의 특징

    TGFE계열의 유량계는 기체측정용으로 기체는 압력과 온도의 변화에 따라 체적량이 바뀜으로 온도와

    압력 보상이 필요로 한다. TFGE계열은 실시간 온도와 압력변화를 반도체형 센서가 측정하여 보상함으

    로 작업 상황하의 유량을 직접 표준 상황하의 유량으로 바꾸어준다. 본 TGFE 기체터빈 유량계 부착된

    모든 센서는 첨단산업분야에 사용되는 초소형 반도체 센서를 탑재하여 기체 유동장애를 최소화함으로

    최고의 성능과 높은 정밀도를 발휘한다.

    1) 고정도의 유량측정이 가능하다.(±1%).

    2) 순시, 적산, 온도, 압력, 보상비율을 동시 디스플레이가 가능하다.

    3) 사용자 및 관리자 모드(Mode)를 통한 온라인 수정이 가능하다.

    4) 구조가 간단하여 유지보수가 쉽다.

    5) 내구성 및 절연성이 우수하다.

    6) 고기능 적산계(Totalizer)를 탑재함으로 공정관리가 편리하다.

    1.2 적용기체(Permissible types of gases)

    TGFE의 표준 설계는 부식성이 없는 기체 측량에 사용된다.

    특히 천연가스의 경우 무역적 계량에 널리 사용되며, 여러 가지 공업원료가스의 주요계량, 가스공급소

    등에도 사용이 가능하다.

  • TMS KOREA CO., LTD.

    TEL : +82-53-854-7361 A/S Center : +82-53-854-7363 Homepage : http://www.tms-k.com

    - 2 -

    2. 주요 사양

    2.1 제품 사양

    1) General

    ◈ Power : Inside power supply 3.6Volt Lithium battery

    Output power supply 12~24VDC

    ◈ Display : 31-Digit-LCD

    (Accumulated flow rate 10digit, Instantaneous flow rate 8digit, Pressure 6digit, Temperature

    5digit, Accumulated flow rate percentage 3digit)

    ◈ Display updata rate : 2sec

    ◈ Operating temperature : 0~+60℃

    ◈ LCD display temperature : -10~+60℃

    ◈ Storage temperature : -20~+70℃

    2) Frequency input

    ◈ Frequency range : 0Hz to 5KHz

    3) Output signal

    ◈ Flow pulse signal output (output distance less than 50m)

    ◈ 4~20mA signal output (output distance less than 200m)

    ◈ RS-485 communication connection signal.

    (long distance data transmission)

    4) Operating condition

    ◈ Environmental temperature : -30℃~+60℃

    ◈ Medium temperature : -20℃~+80℃

    ◈ Atmospheric pressure : 0~6bar, 0~12bar

    ◈ Relative humidity : 5%~95%

    5) Explosion-proof class

    ◈ Internal pressure explosion-proof : Exd ⅡB T5

    ◈ Water proof class : IP 65

    6) Accuracy within

    ◈ Temperature and pressure compensation : ±0.5%

    ◈ Pressure sensor : ±0.5%

    ◈ Temperature sensor : ±0.5%

    ◈ Repetitive : ±0.2%

    ◈ Accuracy : ±1%(above 0.2 Qmax)

  • TMS KOREA CO., LTD.

    TEL : +82-53-854-7361 A/S Center : +82-53-854-7363 Homepage : http://www.tms-k.com

    - 3 -

    2.2 내부구조

    Controller

    Turbine

    Wheel

    Flow

    straightener

    Body

    Pressure sensor

    Flow sensor

    Tempera tu re

    sensor

    Fig. 1 유량계 상세도

    2.3 제품 치수

    Fig. 2 유량계 치수 그림

  • TMS KOREA CO., LTD.

    TEL : +82-53-854-7361 A/S Center : +82-53-854-7363 Homepage : http://www.tms-k.com

    - 4 -

    Table 1. 유량계 치수표

    Model

    Specification

    Size

    (mm)

    1.6 MPa(mm)

    L H D C nφ

    TGFE-A050 50 150 353 φ165 φ125 4-φ18

    TGFE-A080 80 260 381 φ200 φ160 8-φ18

    TGFE-A100 100 300 402 φ220 φ180 8-φ18

    TGFE-A150 150 450 145 φ285 φ240 8-φ23

    TGFE-A200 200 600 425 φ340 φ295 12-φ23

    2.4 유량범위

    ◈ 최대 유량은 온도, 압력 보상을 거치지 않은 표준유량이다.

    ◈ 최소유량은 최대유량과 유량범위의 비를 통해 계산할 수 있다.

    ◈ 최대압력 손실은 최대 표준유량에서의 압력 손실을 가르친다.

    Table 2. 제품형식에 따른 유량범위

    Model

    Specification

    Size

    (mm)

    Flow

    (㎥/h)Scale

    Accuracy

    (%)

    Pressure lose

    (△P(kPa))

    Case

    material

    TGFE-A050-100 50 100 30:1

    ±1.5% for

    Qmin to 0.2

    Qmax

    ±1% for

    0.2 Qmax to

    Qmax

    1.2

    1.6MPa

    Aluminum

    alloy

    TGFE-A080-160 80 160 30:1 0.5

    TGFE-A080-250 80 250 30:1 0.9

    TGFE-A080-400 80 400 30:1 1.4

    TGFE-A100-400 100 400 30:1 0.4

    TGFE-A100-650 100 650 30:1 0.5

    TGFE-A150-1000 150 1000 30:1 0.6

    TGFE-A150-1600 150 1600 30:1 0.9

    TGFE-A200-1600 200 1600 30:1 0.3

    TGFE-A200-2500 200 2500 30:1 0.8

    ◈ 스틸 재질의 2.5MPa와 고객의 수요에 따라 더욱 높은 등급의 유량계 제작 가능.

    ◈ 설치조건 : 유량계와 배관의 연결방식은 Flange로 연결하며, Flange규격은 DIN규격으로 제작.

    ◈ 유량계 전후단 지관거리 : 전직관단 ≥5DN; 후직관단 ≥2DN

  • TMS KOREA CO., LTD.

    TEL : +82-53-854-7361 A/S Center : +82-53-854-7363 Homepage : http://www.tms-k.com

    - 5 -

    2.5 측정 정밀도

    ±1.5% for Qmin to 0.2 Qmax ±1 for 0.2 Qmax to Qmax

    Fig. 3 Calibration curve of a turbine meter

    3. 사용상의 주의사항

    본 제품은 공장에서 충분한 검사를 실시하여 출하되었습니다.

    본 제품이 귀사에 도착하였다면, 외관을 Check하시어 운반도중 사고 등으로 손상이 없는가를 확인하

    여 주십시오.

    본 항에서는 사용에 있어서 필요한 주의사항을 기재하고 우선 본 항을 잘 읽어 주시기 바랍니다. 본

    항 기재이외의 사항에 관해서는 관계하는 항목을 참조하여 주시기 바랍니다.

    문의사항이 있으시면, 구입처 또는 당사 Service Center 또는 대리점으로 연락 주십시오.

    3.1 제품명판 확인

    본 제품은 1대씩 사양에 맞추어 출하되고 있으니 계수부 뒷면 혹은 정면에 제품기호(Model Code),

    제조번호 등이 기재되어 있습니다.

    주문사양품과 동일한지를 확인 하여 주시기 바랍니다.

    1) 계기를 따라오는 서류

    ◈ 사용설명서

    ◈ 제품합격증(성적서)

    ◈ 패킹 리스트

    ◈ 품질정보 추적카드

  • TMS KOREA CO., LTD.

    TEL : +82-53-854-7361 A/S Center : +82-53-854-7363 Homepage : http://www.tms-k.com

    - 6 -

    3.2 운반에 관한 주의사항

    1) 운반중의 사고로 손상되는 것을 막기 위해, 되도록 당사에서 출하시의 포장 상태로 하여 설치 장

    소로 운반하여 주시기 바랍니다.

    2) 운반 중 충격을 주시 않도록 하여 주십시오.

    3.3 보관에 관한 주의사항

    제품이 도착한 후에, 설치까지의 기간이 길다는 것을 미처 생각지 못하는 것에서부터 고장이 발생한다

    고 생각됩니다.

    사전에 장기간의 보관이 예상되어지는 경우는 이하의 항목에 주의하여 주십시오.

    1) 제품은 당사에서 출하 하였을 때의 포장 상태로 보관하여 주십시오.

    2) 보관 장소는 하기의 조건을 만족하는 곳을 선정하여 주십시오.

    ◈ 비나 물의 영향을 받지 않는 장소

    ◈ 진동이나 충격이 적은 장소

    ◈ 보관 장소의 온도나 습도가 가능한 상온상습(25℃, 65%)인 장소.

    3) 한번 사용한 제품을 보관하는 경우는 관로 및 Case외관 등에 측정유체가 부착하는 일이 없도록

    청정한 Air, N2, Gas등으로 Purge하여 주십시오.

    3.4 설치장소의 주의사항

    1) 본 유량계는 Sensor부가 자기Sensor를 사용하여, 회전자에 있는 발신자석의 자계를 검출하고 있

    습니다. 가능한 자계를 발생시키는 것으로부터 떨어져서 설치하고 10W정도의 전자 Valve를 설치하는

    경우는 유량계로부터 10㎝이상 떨어져서 설치하여 주십시오.

    2) 본제품은 옥내 설치용이므로 직접 비나 Oil, 직사광선에 영향을 받지 않는 장소에 설치하여 주시

    시오.

    3) 제품 사양서를 참조하시어 온도나 설치 장소에 맞는 곳에 설치하여 주십시오.

    4) 유량계는 수평 설치를 건의하며 설치 시 유량계의 주축은 배관 주축과 일치하여야 하며 Gasket은

    배관 내부에 들어가서는 안 된다.

    5) 유량계 설치 시 배관 내부 매체의 유동방향은 유량계가 표기한 유동방향과 일치하여야 한다.

    6) 측량 매체의 실제 사항에 따라 유량계 앞부분에 기체 여과기를 선택 설치하여야 한다.

    7) 새로 건설된 배관은 반드시 깨끗이 청소한 후 유량계를 설치 할 수 있으며, 배관내의 쓰레기가 유

    량계 내부의 부품을 파손시키는 것을 방지하여야 한다.

    8) 미터 설계 설치 시 유량계 전 5D, 후 2D의 직관단 요구를 보장하여야 한다.

    9) 유량계 사용시 전후 밸브는 천천히 열고 닫아야 하며 기류의 강렬한 충격으로 기기가 파손되는것

    을 방지하여야 한다.

  • TMS KOREA CO., LTD.

    TEL : +82-53-854-7361 A/S Center : +82-53-854-7363 Homepage : http://www.tms-k.com

    - 7 -

    4. 주문시 주의 사항

    4.1 합리적인 유량측정 범위내의 유량계 선택

    유량범위는 모두 조작상태(Operating condition) 체적유량범위로서 사용자는 모델 선택시 조작상태

    (Operating condition)용 기체량에 근거하여 매개변수에 따라 계기를 선택하여야 g나다. 만약 표준상태

    (Standard condition 101.325kPa, 20℃)체적유량을 알고있다면 아래 공식에 의하여 조작상태 체적유량

    으로 환산한 후 다시 매개변수에 따라 계기를 선택하여야 한다.

    ×

    ×

    ×

    ×

    ×

    ×

    Qo : 조작상태 체적유량 Tg : 유량계검사점의절대온도(273.15+t)K

    Qs : 표준상태(101.325kPa,20℃) 체적유량 TN : 표중상태하의 절대온도(293.15K)

    PN : 표준대기압(101.325kPa) t : 게이지 온도(℃)

    Pa : 대기압(kPa) Zg : 작업상태하의 압축계수

    Pg : 게이지 압력(kPa) ZN : 표준상태하의 기체압축계수

    상대밀도 이 0.75보다 작거나 같고 질소와 이산화탄소의 몰 분수가 각각 0.15를 초과하지 않을 시

    석유천연가스업계표준 SY/T6143-1996중 천연가스 초압축인자 FZ의 계산방법에 근거하여 Zg와Zn의 비

    율을 확정하는바

    이다.

    국가표준 GB/T17747.2-1999중 규정에 따라 계산한다.(계량기 모델 선택 계산시 대략적으로 ZN≈Zg)

    4.2 주문시 매개변수 자료 협조

    1) 배관 직경

    2) 최소, 최대 유량(상태조건 표기)

    3) 최소, 최대 압력

    4) 최소, 최대 온도

    5) 환경온도

    6) 기체 종류

    7) 신호 출력 전송 거리

    8) 기타(기업에 필요한 서류 및 조건)

  • TMS KOREA CO., LTD.

    TEL : +82-53-854-7361 A/S Center : +82-53-854-7363 Homepage : http://www.tms-k.com

    - 8 -

    5. 기타 주의사항 및 보증기간

    1) 유량계 분해 및 조립을 하지 마십시오.

    2) 상기 취급시 주의사항에 명기된 내용은 제품고장을 유발할 수 있기 때문에 반드시 지켜 주십시오.

    3) 그밖에 특별한 규정이 없는 한, 본 제품의 제품보증은 다음과 같습니다.

    보증기간 : 납품후 18개월 또는 사용개시 후 12개월 중 짧은 기간에 당사 제조상의 문제로 인한 것이 명확한 고장에 대해서는, 무상으로 수리 또는 교환해 드립니다.

    보증범위 : 다음의 경우는 보증대상이 되지 않습니다.① 천재 등 불가항력에 의해서 발생한 고장.

    ② 취급을 잘못해서 발생한 고장.

    ③ 부적절한 환경에서 사용한 경우.

    ④ 분해하거나 개조를 한 경우.

    ⑤ 규정 사양범위를 넘어서 사용한 경우.

    ⑥ 기타, 당사의 책임이 아니라고 판단되는 경우

    A/S는 구입처 또는 가까운 대리점으로 연력 주시면 신속히 처리해 드립니다.

  • TMS KOREA CO., LTD.

    TEL : +82-53-854-7361 A/S Center : +82-53-854-7363 Homepage : http://www.tms-k.com

    - 1 -

    FDC-4000 적산계

    1. 제품소개(Introduction) 및 특징(Feature)

    FDC-4000 Series는 터빈 센서와 같이 펄스를 발생 시키는 일반적인 유량계에 사용하기 위해 특별히

    고안된 현장폭발 차단형 유량적산계이다.

    FDC-4000 Series는 유량계로부터 Flow Signal를 입력받아 Operating Condition 체적유량(Qo),

    Standard Condition 체적유량(Qs),순시유량, 온도, 압력, Qo와Qs값의 백분율을 모니터링 할 수 있는 특

    징을 지니고 있으며, 표준상태의 조건을 온도 0, 12, 15, 20℃,압력101.325kPa을 선택하여 사용할 수가

    있다.

    특히 수동 조작Key를 이용하여 계기의 각종 매개변수를 설정 할 수 있을 뿐만 아니라, 각종 출력기능

    4~20mA, Pulse Output 출력은 기본 사양으로 사용자의 선택에 따라 적용가능하며, 옵션 사항으론

    RS-485 통신을 선택할 수 있어서 각종 공정관리 및 사무실에서 직접 데이터를 받아 관리 할 수 있다.

    ◈ 내부전원 : 3.6V 리듐배터리(소비전력: 평균 0.7mW, 연속 2.5mW)

    (국제표준규격 : ER32L615, 대기사용 7년, 연속사용 5년)

    ◈ 외부전원 : 12~24VDC, 전체 소비전력 4.8W이하

    측정매개물은 천연가스, 압축공기 및 기타 부식성이 없고 오일과 반응하지 않는 기체를 측정할수 있

    다.

    ◈ 방폭형식 : Exd ⅡB T5

    ◈ 방폭합격증 번호 : 07-1-725-Q1

    2. 적산계 코드

    ◈ FDC-4000-A

    A

    Type

    4~20mA Analog type electric signalPulse Output RS-485 communication

  • TMS KOREA CO., LTD.

    TEL : +82-53-854-7361 A/S Center : +82-53-854-7363 Homepage : http://www.tms-k.com

    - 2 -

    3. LCD 기본화면 구성

    Qo : 온도․압력보상 전 Operating condition 체적유량(N㎥) 온도․압력보상 전 Operating condition 순시유량(N㎥/h)Qs : 온도․압력보상 후 Standard Condition 체적유량(N㎥) 온도․압력보상 후 Standard Condition 순시유량(N㎥/h)kPa : 절대압력

    ℃ : 절대온도

    Qa : Operating condition와 Standard Condition의 백분율(%)

    4. 외부 결선법 및 외부결선 치수

    4.1 출력 단자

    AC 500V a minute

    1000MΩ Min, 5mΩ Max

    Pin connection

    1 : 24VOLT

    2 : I-OUT

    3 : 485-B

    4 : 485-A

    5 : P2

    6 : P1

    7 : P0

    8 : GND

    외부 전원 공급 시 (P0, P1, P2)최대 펄스 출력의 값이 전원 전압이다.

    ◈ P0 : 온도, 압력 보상 후의 적산량을 선형 펄스로 출력

    (최대 출력 펄스 1000Hz~5000Hz에서 선택 가능)

    BOARD상의 DIP SWITCH(SW1)의 1번 단자를 OFF로 하면 OPEN COLLECT 방식의

    출력이 되며, ON으로 했을 경우 10K 저항을 통한 OUT PULSE 출력이 된다.

    ◈ P1 : 온도 압력 보상 전의 적산량을 선형 펄스로 출력

  • TMS KOREA CO., LTD.

    TEL : +82-53-854-7361 A/S Center : +82-53-854-7363 Homepage : http://www.tms-k.com

    - 3 -

    표 시 기 능 명 칭 기 능 설 명

    SW1 메뉴 전환 키 영구 적산, 순시, 주파수 등의 디스플레이 모드를

    변환 하고자 할 때 사용합니다.

    SW2 하위 메뉴 진입 키 변경 하고자 하는 매개변수의 메뉴로 진입 할 때,

    파라미터의 자릿수를 증가 시킬 때 사용합니다.

    SW3 업 키 매개변수 값을 증가시킬 때 사용합니다.

    SW4 저장 키 매개변수 값을 저장 할 때 사용합니다.

    (최대 출력 펄스 1000Hz~5000Hz에서 선택 가능)

    BOARD상의 DIP SWITCH(SW1)의 2번 단자를 OFF로 하면 OPEN COLLECT 방식의

    출력이 되며, ON으로 했을 경우 10K 저항을 통한 OUT PULSE 출력이 된다.

    ◈ P2 : 유량센서가 측량한 Frequency 펄스를 직접 출력

    BOARD상의 DIP SWITCH(SW1)의 3번 단자를 OFF로 하면 OPEN COLLECT 방식의

    출력이 되며, ON으로 했을 경우 10K 저항을 통한 OUT PULSE 출력이 된다.

    ◈ I-OUT : 4~20mA 전류 출력

    ◈ RS-485(A,B) : HALF DUPLEX 방식

    4.2 매개변수 조작 Key 단자

    AC 500V a minute

    1000MΩ Min, 5mΩ Max

    Pin connection

    1 : SW-1

    2 : SW-2

    3 : SW-3

    4 : SW-4

    5 : GND

    영구 적산, 순시, 주파수 등의 디스플레이 모드에서 SW2 키를 누르면 IntErFACE 라는 글자가 디스플

    레이 되고, 이 화면에서 SW1 키를 누르면 FLOW-SET 메뉴로 화면이 전환 되며 다시 SW2 키를 누르

    면 K-FACTOR 설정 메뉴로 진입을 하게 된다.

    K-FACTOR 메뉴는 SET-FrEq(주파수 대역 설정 메뉴)와 SEt - COUnt(K-FACTOR(3600×유량 센서

    에서 측정되는 주파수(Hz)/순시유량) 설정 메뉴)로 나누어 져 있다.

    우선 K-FACTOR 설정 메뉴로 진입을 하게 되면 SET-FrEq(주파수 대역 설정 메뉴)라는 화면이 나타

    나며 여기서 SW2 키를 누르면 10개(0~9)의 주파수 대역을 설정 할 수 있는 주파수 대역 설정 메뉴의

    첫 번째 (Fr-0 0000) 화면이 디스플레이 된다.

    여기에서 SW2(자릿수 이동),SW3(커서가 위치한 자리의 값을 증가) 키를 이용하여 원하는 주파수 대

    역 값을 설정하고 SW4 키를 눌러 설정한 값을 저장 하면 된다.

    그리고 두 번째~ 열 번째 주파수 대역 설정 화면으로의 전환은 SW1 키를 눌러 전환을 하면 된다.

  • TMS KOREA CO., LTD.

    TEL : +82-53-854-7361 A/S Center : +82-53-854-7363 Homepage : http://www.tms-k.com

    - 4 -

    열 번째 주파수 대역 설정 화면(Fr-9 0000)에서 SW1 키를 누르면 SET-FrEq 화면이 디스플레이 되

    고, 이 화면에서 다시 SW1 키를 누르면 SEt - COUnt(K-FACTOR 설정 메뉴)로의 화면 전환이 이루어

    지며 SW2 키를 누르면 첫 번째 주파수 대역에서의 K-FACTOR 설정 메뉴(COn - 000000)로 진입이

    이루어진다.

    주파수 대역과 같이 K-FACTOR 값 또한 10개(COn - 000000 ~ COn - 900000)의 설정 구간으로

    나누어져 있으며 설정 방법도 위에서 설명한 주파수 대역 설정 방법으로 하면 됩니다.

    ※모든 다른 파라미터의 설정도 위와 같은 방법으로 이루어집니다.

    5. FLOW - SET MENU

    본 Mode진입 방법은 기본화면 Mode에서 SW2 Key를 누르고 SW1 Key를 누르면 FLOW-SET구간으

    로 진입하게 되고 여기서 SW2 Key를 누르면 5.1항목(SEt-FrEq) 구간으로 진입되며, SW1 Key를 누르

    면 5.2~5.4항목 Mode로 넘어간다. 매개변수 값 설정은 4.2항목을 참조하여 설정하면 된다.

    5.1 Set Frequency 대역

    표 시 기능 설명

    Fr - 0 0000 0번째 주파수 대역 설정

    (설정한 주파수 미만의 대역을 가짐 )

    Fr - 1 0000 1번째 주파수 대역 설정

    (0번째 설정한 주파수 값 이상, 설정한 주파수 값 미만의 대역)

    Fr - 2 0000 2번째 주파수 대역 설정

    (1번째 설정한 주파수 값 이상, 설정한 주파수 값 미만의 대역)

    Fr - 3 0000 3번째 주파수 대역 설정

    (2번째 설정한 주파수 값 이상, 설정한 주파수 값 미만의 대역)

    Fr - 4 0000 4번째 주파수 대역 설정

    (3번째 설정한 주파수 값 이상, 설정한 주파수 값 미만의 대역)

    Fr - 5 0000 5번째 주파수 대역 설정

    (4번째 설정한 주파수 값 이상, 설정한 주파수 값 미만의 대역)

    Fr - 6 0000 6번째 주파수 대역 설정

    (5번째 설정한 주파수 값 이상, 설정한 주파수 값 미만의 대역)

    Fr - 7 0000 7번째 주파수 대역 설정

    (6번째 설정한 주파수 값 이상, 설정한 주파수 값 미만의 대역)

    Fr - 8 0000 8번째 주파수 대역 설정

    (7번째 설정한 주파수 값 이상, 설정한 주파수 값 미만의 대역)

    Fr - 9 0000 9번째 K-Factor 값 설정

    (9번째 설정한 주파수 대역에서의 K-Factor 값)

  • TMS KOREA CO., LTD.

    TEL : +82-53-854-7361 A/S Center : +82-53-854-7363 Homepage : http://www.tms-k.com

    - 5 -

    표 시 기능 설명

    COn - 000000 0번째 K-Factor 값 설정

    (0번째 설정한 주파수 대역에서의 K-Factor 값)

    COn - 100000 1번째 K-Factor 값 설정

    (1번째 설정한 주파수 대역에서의 K-Factor 값)

    COn - 200000 2번째 K-Factor 값 설정

    (2번째 설정한 주파수 대역에서의 K-Factor 값)

    COn - 300000 3번째 K-Factor 값 설정

    (3번째 설정한 주파수 대역에서의 K-Factor 값)

    COn - 400000 4번째 K-Factor 값 설정

    (4번째 설정한 주파수 대역에서의 K-Factor 값)

    COn - 500000 5번째 K-Factor 값 설정

    (5번째 설정한 주파수 대역에서의 K-Factor 값)

    COn - 600000 6번째 K-Factor 값 설정

    (6번째 설정한 주파수 대역에서의 K-Factor 값)

    COn - 700000 7번째 K-Factor 값 설정

    (7번째 설정한 주파수 대역에서의 K-Factor 값)

    COn - 800000 8번째 K-Factor 값 설정

    (8번째 설정한 주파수 대역에서의 K-Factor 값)

    COn - 900000 9번째 K-Factor 값 설정

    (9번째 설정한 주파수 대역에서의 K-Factor 값)

    표 시 기능 설명

    ZdAtA00000 기체 압축 계수(0.0000 ~ 1.0000)

    5.2 K-FACTOR COUNT

    5.3 SET - TEMPERATURE

    표 시 기능 설명

    tEmPE 00.00 기준 온도 값 00.00˚C

    tEmPE 12.00 기준 온도 값 12.00˚C

    tEmPE 15.50 기준 온도 값 15.50˚C

    tEmPE 20.00 기준 온도 값 20.00˚C

    5.4 SET - Z DATA

  • TMS KOREA CO., LTD.

    TEL : +82-53-854-7361 A/S Center : +82-53-854-7363 Homepage : http://www.tms-k.com

    - 6 -

    표 시 기능 설명

    HF 0000.00 최대 유량 대역(0000.00 ~ 9999.99)

    설정한 값 이상에서 설정한 최대 전류 출력

    표 시 기능 설명

    LF 0000.00 최소 유량 대역(0000.00 ~ 9999.99)

    설정한 값 이하에서 설정한 최소 전류 출력

    표 시 기능 설명

    HC 0000 최대 유량시 출력 전류 설정(0000 ~ 3999)

    표 시 기능 설명

    LC 0000 최소 유량시 출력 전류 설정(0000 ~ 3999)

    표 시 기능 설명

    qO 0000 온도, 압력 보상 전 펄스 출력 최고 주파수

    - 1000,2000,3000,4000,5000 Hz

    표 시 기능 설명

    qS 0000 온도, 압력 보상 후 펄스 출력 최고 주파수

    - 1000,2000,3000,4000,5000 Hz

    표 시 기능 설명

    CP 0000 Press Sensor Data의 기울기 값(0000 ~ 9999)

    ※실제 값은 (0.0000 ~ 0.9999)

    6. INTERFACE - SET MENU

    본 Mode진입 방법은 기본화면 Mode에서 SW2 Key를 두 번 누르면 6.1항목(HIGH-FLOW) 구간으로

    진입되며, SW1 Key를 누르면 6.2~6.9항목 Mode로 넘어간다. 매개변수 값 설정은 4.2항목을 참조하여

    설정하면 된다.

    6.1 HIGH - FLOW

    6.2 LOW - FLOW

    6.3 20mA - dAtA

    6.4 4mA - dAtA

    6.5 qO - FrEq

    6.6 qS - FrEq

    6.7 CAL - PrESS

  • TMS KOREA CO., LTD.

    TEL : +82-53-854-7361 A/S Center : +82-53-854-7363 Homepage : http://www.tms-k.com

    - 7 -

    표 시 기능 설명

    Pd 00000

    Press Sensor Data의 Y절편 값(00000 ~ 19999)

    수의 첫 번째 자리는 부호 비트(0(+),1(-))

    ※실제 값은 (00.00 ~ 99.99)

    표 시 기능 설명

    Id 000 485 통신에서의 각 기기의 번호(000 ~ 999)

    STX ID COMMAND CHECK SUM ETX

    DATA NAME 내용 SIZE(BYTE)

    STX 02H 1

    ID 적산계 ID 3

    COMMAND 아래참조. 4

    CHECK SUM 주1) 2

    ETX 03H 1

    6.8 PrESS - dAtA

    6.9 485 - Id

    7. 485 Communication Protocol

    본 FDC-4000은 호스트장비에서 적산계의 현재 적산된 데이터를 RS485 규격의통신방식으로 원격지

    에서 취득 할 수 있다.

    취득 할 수 있는 데이터는 온도 압력 보상전의 Total 적산량, 온도 압력 보상후의 Total 적산량, 온도

    압력 보상전의 ㎥/h 순시량, 온도 압력 보상후의 ㎥/h 순시량, 압력, 온도 이상 6가지이다.

    7.1 데이터 포맷

    Baud Rate : 9,600bps

    Data bit : 8 bit

    Stop bit : 1bit

    Parity bit : none

    Data code : ASCII

    7.2 Query Command Spec

    호스트 장비에서 적산계의 원하는 데이터에 대한 질의구문의 규격은 아래와 같이 10Byte로 구성되어

    있다.

    주1) STX에서 COMMAND 까지 각각의 바이트를 더하여 하위 1바이트를 2 의보수로 취하여 상위 하위 니블을 아스키 값으로 변환한 값(알파벳은 대문자).

    STX 와 ETX 를 제외한 모든 DATA는 아스키 값.

  • TMS KOREA CO., LTD.

    TEL : +82-53-854-7361 A/S Center : +82-53-854-7363 Homepage : http://www.tms-k.com

    - 8 -

    COMMAND 의미

    0000 Qo 영구적산(TOT)

    0001 Qs 영구적산(TOT)

    0002 Qo 순시량(m3/h)

    0003 Qs 순시량(m3/h)

    0004 압력

    0005 온도

    STX ID COMMAND D0~D9 CHECK SUM ETX

    DATA NAME 내용 SIZE(BYTE)

    STX 02H 1

    ID 적산계 ID 3

    COMMAND 아래참조. 4

    DATA D0 ~ D9 10

    CHECK SUM 주1) 2

    ETX 03H 1

    COMMAND 의미

    0000 Qo 영구적산(TOT)

    0001 Qs 영구적산(TOT)

    0002 Qo 순시량(m3/h)

    0003 Qs 순시량(m3/h)

    0004 압력

    0005 온도

    7.2.1. Query code spec

    7.3 Response Spec

    호스트장비의 질의에 대한 적산계의 응답구문의 규격은 아래와 같이 21Byte로 구성되어 있습니다.

    주1) STX에서 DATA 까지 각각의 바이트를 더하여 하위 1바이트를 2 의보수로 취하여 상위 하위 니블을 아스키 값으로 변환한 값(알파벳은 대문자).

    STX 와 ETX 를 제외한 모든 DATA 는 아스키 값. 온도 일 경우 D0 가 부호 바이트(D0=0x00 이면 + 온도, D0=0x01 이면 - 온도)

    7.3.1 Query code spec

  • TMS KOREA CO., LTD.

    TEL : +82-53-854-7361 A/S Center : +82-53-854-7363 Homepage : http://www.tms-k.com

    - 9 -

    8.각 그룹 메뉴 및 파라미터 SETTING 방법

    8.1 디스플레이 모드의 종류 및 모드 전환

    온도·압력 보상 전 유량 (SW1 Key)⇨ 온도·압력 보상 후 유량 (SW1 Key)⇩

    SW1⇨ SW1⇩ SW1⇩SW1⇧ SW1⇦

    주파수 (SW1 Key )⇩

    컨트롤러 시리얼 넘버 ( SW1 Key )⇧ ⇦ 압력계 디지털 값 ( SW1 Key)

  • TMS KOREA CO., LTD.

    TEL : +82-53-854-7361 A/S Center : +82-53-854-7363 Homepage : http://www.tms-k.com

    - 10 -

    8.2 파라미터 설정의 예

    ※아래 그림은 FLOW-SET MENU 중 K-FACTOR 메뉴의 파라미터 설정 예 이다. 다른 모든 메뉴들도

    아래와 같은 방법을 통해 파라미터 값을 설정 및 변경 하면 된다.

    8.2.1 FLOW SETTING MENU의 진입

    SW2 Key⇩

    SW1 Key⇩

  • TMS KOREA CO., LTD.

    TEL : +82-53-854-7361 A/S Center : +82-53-854-7363 Homepage : http://www.tms-k.com

    - 11 -

    8.2.2 K-FACTOR SETTING MENU

    K-FACTOR SETTING MENU는 크게 SEt - FrEq(주파수 설정 메뉴)와 SEt - COUnt (K-Factor(계량

    기계수)설정 메뉴)로 되어 있습니다.

    8.2.2.1 SEt - FrEq(주파수 설정 메뉴)의 파라미터 설정 방법

    ex)첫 번째 주파수(Hz) 대역 17Hz의 설정

    8.2.1항목을 통해 Set Menu진입(SW2 Key) ⇨ 주파수 구간 진입(SW2 Key)⇩

    Fr-1구간 이동(SW1 Key) ⇨ 주파수 첫 번째 구간 진입(SW3 Key)⇩

    Fr-0 구간 저장( SW4 Key)⇧ 정수 첫 번째 자리 값 설정(SW2 Key)⇩

    정수 두 번째 자리 값 설정(SW3 Key)⇧ ⇦ 정수 자리 이동☞ 다른 주파수 대역 설정 방법은 위의 그림에서처럼 SW1 키를 눌러 다음 주파수 대역 설정 화면으로

    전환 한 뒤 예제 그림과 같은 과정으로 파라미터 값을 설정 하면 된다.

  • TMS KOREA CO., LTD.

    TEL : +82-53-854-7361 A/S Center : +82-53-854-7363 Homepage : http://www.tms-k.com

    - 12 -

    8.2.2.2 SEt - COUnt(K-FACTOR 계수 설정 메뉴)의 파라미터 설정 방법

    ex) K-Factor = 주파수(Hz)×시간(3600)) / 순간유량(㎥/h)

    62 = 2 * 3600 / 116

    Fr-9 구간 후 SEt-FrEq 상태(SW1 Key)⇨ 주파수 구간 진입(SW2 Key)⇩

    COn-1구간 이동(SW1 Key) ⇨ 주파수 첫 번째 구간 진입(SW3 Key)⇩

    COn-0 구간 저장(SW4 Key)⇧ 정수 첫 번째 자리 값 설정(SW2 Key)⇩

    정수 두 번째 자리 값 설정( SW3 Key) ⇦ 정수 자리 이동☞ 다른 K-FACTOR 계수의 설정 방법은 위의 그림에서처럼 SW1 키를 눌러 다음 K-FACTOR 계수

    설정 화면으로 전환 한 뒤 예제 그림과 같은 과정으로 파라미터 값을 설정 하면 된다.

  • NOTE:

    ABROAD OFFICE

    ◈ TMS KOREA CO., LTD(KOREA)

    Technopark R&DB Center,33, Buho-ri, Hayang-eup,

    Gyeongsan-si, Gyeongsangbuk-do, Seoul 712-701 Korea

    Tel : +82-53-854-7361 Fax : +82-53-854-7366

    e-mail : [email protected]

    ◈ Beijing MADAS Gas Tech Development Co.,LTD(CHINA)

    RM No.B 1712 U-SPACE B/D No.8 Guangqunewai Street,

    Chaoyang District, Beijing CHINA 100022 Tel : +86-10-58612601 Fax : +86-10-58612701

    e-mail : [email protected]

    ◈ FC KOREA CO., LTD.(VETNAM)

    18/2 bis Quach Van Tuan St., Ward 12, Tan Binh Dist, HCM city

    Tel : +84-08-408-2660,2659 Fax : +84-08-811-0237