garage & canopy - lighting.philips.com · surface mount top view recessed mount bottom view...
TRANSCRIPT
SlenderForm_SFC_LED 12/18 page 1 of 4
Accessories
(order separately)
FSIR-1005
MR hand held programmer
For use with 'MR' motion response when field programming is required. If desired, only one is needed per job.
Order CodeLED Qty
System Current
(mA)
Color Temp
(K)
Ave System Watts
(W)
3 5W 5R CD
Lumen Output
Efficacy (lm/W)
Lumen Output
Efficacy (lm/W)
Lumen Output
Efficacy (lm/W)
Lumen Output
Efficacy (lm/W)
SFC or SFCR-48L-250-NW-G2 48 250 4000 38 4636 121 4804 125 4660 122 4656 122
SFC or SFCR-48L-400-NW-G2 48 400 4000 60 6932 116 7182 121 6968 117 6962 117
SFC or SFCR-48L-550-NW-G2 48 550 4000 82 9323 114 9660 119 9372 115 9364 115
SFC or SFCR-48L-700-NW-G2 48 700 4000 104 11609 112 12028 116 11670 112 11659 112
SFC or SFCR-48L-900-NW-G2 48 900 4000 133 14184 107 14696 111 14258 107 14245 107
Note: Due to rapid and continuous advances in LED technology, LED luminaire data is subject to change without notice and at the discretion of Signify. Lumen output by optic type will vary slightly. See IES files when available. All technical data is subject to change.
LED Wattage and Lumen Values Standard SFC & SFCR luminaires
SFC
SFCR
1. SFCR recessed mount NOT available with 900mA, MR, PCB, BX or JB.
2. Luminaire includes 0-10V input wires for dimming control by a dimming system supplied by others.
3. Only available in 120 through 277V.
4. Specify actual input voltage.
5. Not available with SFCR recessed mount units.
6. Shroud is for Pendant mount only. 12" (30.48cm) minimum pendant length required. Pendant by others. Option is installed in the field only.
7. For rigid and swivel pendant mount. Pendants by others.
Ordering guide example: SFC-DD-5W-48L-700-NW-G2-UNV-MGY
Prefix
–
Controls
–
Distribution
–
LED Count
48L –
Drive Current
–
LED Color - Generation
–
Voltage
–
Finish
MGY –
Options
SFC SlenderForm Ceiling luminaire
SFCR SlenderForm Ceiling luminaire (recessed mounting)1
– Standard Luminaire
DD 0-10V Dimming2
MR Motion Response3,5
3 Type III
5W Type V, Wide Distribution
5R Type V, Rectangular Distribution
CD Concentrated Downlight
48L 48 LEDs
250 250mA
400 400mA
550 550mA
700 700mA
900 900mA5
NW-G2 Neutral White 4000K, 70CRI Generation 2
WW-G2 Warm White 3000K, 70CRI Generation 2
CW-G2 Cool White 5700K, 70CRI Generation 2
120 120V
208 208V
240 240V
277 277V
347 347V
480 480V
UNV 120-277V
MGY Medium Gray
F1 Single Fuse (120, 277, 347V)4,5
F2 Double Fuse (208, 240, 277V)4,5
F3 Double Fuse (208, 240, 480V)4,5 Canadian double pull
DL Diffusing Lens (reduces performance significantly)
PCB Button Photocontrol4,5
BX Bird Excluding Shroud5,6,7
JB J-Box for Pendant Mounting5,7
GL Glass Lens assembly
SlenderForm
SFC/SFCR Canopy mount
Garage & Canopy
Gardco SlenderForm SFC/SFCR garage and canopy luminaire features high output LEDs and a sleek, yet powerful, low profile design. The thin 3" profile combined with LED high output performance make SlenderForm the ideal choice for exterior ceiling mount and canopy applications. SlenderForm luminaires also provide LED solutions for parking garage applications requiring higher light levels, including entrances, and for garage areas with high ceilings.
Project:
Location:
Cat.No:
Type:
Lamps: Qty:
Notes:
SlenderForm_SFC_LED 12/18 page 2 of 4
16.10
3.00
4.50
9.37
8.44
15.17
6.00
6.75
6.00
8.44
DRAWN
THE DRAWING ON THIS PRINT AND INFORMATION THEREWITH ARE PROPRIETARY TO PHILIPS GROUP AND SHALL NOT BE USED IN WHOLE OR USED IN PART WITHOUT EXPRESS WRITTEN CONSENT OF SAID COMPANY.
B.CHAMBLESS 09/26/11
1611 CLOVIS BARKER RD. SAN MARCOS, TX. 78666
D
SLENDERFORM VIEWS
SHEET 1 OF 1
REVISION HISTORYREV DESCRIPTION DATE PCN
NOTES: (UNLESS OTHERWISE SPECIFIED):
UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN INCHES AND IN ACCORDANCE WITH ANSI Y 14.5M TOLERANCES: DEC. X: DEC. XX ± .02 DEC. XXX ± .005 FRACTIONS: ANGLES ± .5º
DO NOT SCALE DRAWING
APPROVALS DATE
CHECKED
APPROVAL
APPROVAL
SIZE MODEL #
SFCDWG. NO.
SCALE: REV.
1/1
Dimensions
16.10
3.00
4.50
9.37
8.44
15.17
6.00
6.75
6.00
8.44
DRAWN
THE DRAWING ON THIS PRINT AND INFORMATION THEREWITH ARE PROPRIETARY TO PHILIPS GROUP AND SHALL NOT BE USED IN WHOLE OR USED IN PART WITHOUT EXPRESS WRITTEN CONSENT OF SAID COMPANY.
B.CHAMBLESS 09/26/11
1611 CLOVIS BARKER RD. SAN MARCOS, TX. 78666
D
SLENDERFORM VIEWS
SHEET 1 OF 1
REVISION HISTORYREV DESCRIPTION DATE PCN
NOTES: (UNLESS OTHERWISE SPECIFIED):
UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN INCHES AND IN ACCORDANCE WITH ANSI Y 14.5M TOLERANCES: DEC. X: DEC. XX ± .02 DEC. XXX ± .005 FRACTIONS: ANGLES ± .5º
DO NOT SCALE DRAWING
APPROVALS DATE
CHECKED
APPROVAL
APPROVAL
SIZE MODEL #
SFCDWG. NO.
SCALE: REV.
1/1
Surface mount top view
Recessed mount bottom view
16.1"40.894cm
Surface mount side view Surface mount end view
9.37" / 23.8cm8.44" / 21.44cm
3" / 7.62cm
4.5" / 11.43cm
6.75" / 17.145cm6" / 15.24cm
15.17"38.532cm
6"15.24cm
8.44"21.44cm
Surface mount luminaires with motion response (NOTE: Motion response NOT available with recessed mount).
Motion Sensor
Motion Sensor Module Location
Motion Sensor Module
4.500
18.818
2.715
4.500
18.818
2.715
4.5"11.43cm
2.715"6.896cm
19.50
15.08
16.01 20.4516" 40.6cm
20.5" 52.1cm
15.1" / 38.3cm
19.5" / 49.5cm
SFC & SFCR SlenderForm LED luminaire
Garage & Canopy - Canopy Mount
SlenderForm_SFC_LED 12/18 page 3 of 4
Motion Response Luminaires
Programmable Motion Response
SFC-MR luminaires include a passive infrared (PIR) motion sensor (WattStopper® FS-211 equipped with an FS-L2W lens) capable of detecting motion within 22 feet of the sensor, 360° around the luminaire, when placed at an 8 foot mounting height. The PIR sensor is mounted as indicated in drawings on page 2. Available in 120V or 277V input only. Motion sensor off state power is 0.0 watts.
In Motion Response (MR) luminaires, when no motion is detected for 10 minutes, the Motion Response system reduces the wattage by 80%, to 20% (per RP-20) of the normal constant wattage, reducing the light level accordingly. When motion is detected by the PIR, the luminaire returns to full wattage and full light output. Dimming on low is factory set to 80% with duration set at 10 minutes.
The approximate motion sensor coverage pattern is as shown below.
FSIR-100 Wireless Remote Programming Tool
The FSIR-100 Remote Programming Tool accessory enables on-site field adjustment of sensor settings, including duration and dimming level on low, without the need to connect any wires to the luminaire.
The FSIR-100 Wireless IR Programming Tool is a handheld tool for setup and testing of WattStopper FSP-211. It provides wireless access to the FSP-211 sensors for setup and parameter changes.
The FSIR-100 display shows menus and prompts to lead you through each process. The navigation pad provides a familiar way to navigate through the customization fields.
Within 8'-12' mounting height of the sensor, the FSIR-100 allows modification of the system without requiring ladders or tools simply with a touch of a few buttons.
The FSIR-100 IR transceiver allows bi-directional communication between the FSP-211 and the FSIR-100 programming tool . Simple menu screens let you see the current status of the system and make changes. It can change FSP-211 sensor parameters such as high/low mode, sensitivity, time delay, cut off and more. With the FSIR-100 you can also establish and store FSP-211 parameter profiles.
The FSIR-100 operates on three standard 1.5V AAA Alkaline batteries or three rechargeable AAA NiMH batteries. The battery status displays in the upper right corner of the display. Three bars next to BAT= indicates a
full battery charge. A warning appears on the display when the battery level falls below a minimum acceptable level. To conserve battery power, the FSIR-100 automatically shuts off 10 minutes after the last key press.
You navigate from one field to another using (up) or (down) arrow keys. The active field is indicated by flashing (alternates between
yellow text on black background and black text on yellow background.)
Once active, use the Select button to move to a menu or function within the active field. Value fields are used to adjust parameter settings. They are shown in “less-than/greater-than” symbols: <value>. Once active, change them using (left) and (right) arrow keys. In general the up key increments and the down key decrements a value. Selections wrap-around if you continue to press the key beyond maximum or minimum values. Moving away from the value field overwrites the original value. The Home button takes you to the main menu. The Back button can be thought of as an undo function. It takes you back one screen. Changes that were in process prior to pressing the key are lost.
More information on the FSIR-100 Remote Programming Tool is available at wattstopper.com.
2.33”59.2mm
0.78”19.7mm
FSP-L4: 360° CoverageThe FSP-L4 is designed for mounting at heights between 30’ to 40’ . Its coverage area can be up to 60’ in diameter when mounted at 40’ .
COVERAGE PATTERN
Density and range of the coverage pattern is determined by the type of lens and mounting height .
FSP-L2: 360° CoverageThe FSP-L2 lens provides a 44’ diameter coverage area when mounted at a height of 8’ .
FSP‑L3 High Densi ty/Reduced Range Lens
FSP‑L2 Low Densi ty/Wide Range Lens
03 9636912 12
10
20
0
15
5
151820 15 18 20
20 10 0 10 20
0
20
10
10
20
40 ft
2.33”59.2mm
0.78”19.7mm
30
30
20
10
10
20
0
8
0
10 0
0 33 77 1111 2222
10 2020
44 ft
FSP‑L4 40 Foot High Bay Lens
0 6 12 3061230 20 20
0
10
20
30
40
0 3 6 12 2730
36122730
20 20
036
36
12
27
30
12
27
20
20
60 ft
3.2”81.3mm
0.93”23.6mm
FSP-L3: 360° CoverageThe FSP-L3 has a high density lens that covers a 40’ diameter area at a height of 20’ .
WIRING A SINGLE SENSOR
Non-DimmingDriver
LIN
EN
EU
TRA
L
NEUTRAL
LOAD
* GROUND
Occupancy Sensor
5E4
800.879.8585www.wattstopper.com
1519
5r1
LOA
D
LIN
E
NEU
T(v
iole
t)
(gre
y)
18-20 AWG Solid CU Wire Only
230 VAC, 50 Hz1200W max ballast
FSP-211
GRN
D
DIM
-
DIM
+
14-18 AWG Solid CU Wire Only
High/Low PIR
Non-Dimming Driver
DimmingDriver
LIN
EN
EU
TRA
L
NEUTRAL
*GROUND
GRAY (-)
VIOLET (+)
LOAD
Occupancy Sensor
5E4
800.879.8585www.wattstopper.com
1519
5r1
LOA
D
LIN
E
NEU
T(v
iole
t)
(gre
y)
18-20 AWG Solid CU Wire Only
230 VAC, 50 Hz1200W max ballast
FSP-211
GRN
D
DIM
-
DIM
+
14-18 AWG Solid CU Wire Only
High/Low PIR
Dimming Driver
1 . Determine an appropriate mounting location inside the light fixture . Allow a minimum distance of 0 .2” (5 .1mm) from the wiring end of the sensor to the wall of the fixture .
2 . Drill a hole 1 .30” (33 .0mm) in diameter through the sheet metal in the bottom of the fixture .
3 . Add the rubber gasket to the threaded collar, and install the sensor face down, parallel to the mounting surface . Ensure the rubber gasket touches the inside surface of the fixture . Install the plastic nut securely against the fixture to a torque of 25-30 in-lbs to ensure IP rating is maintained .
4 . Align the locking features between the sensor and lens module and push the lens module forward until the o-ring seals firmly . Turn the lens module clockwise to ensure it locks in place .
5 . Connect load and supply wires as shown in wiring diagram .6 . Restore power from the circuit breaker .
CAUTION TURN THE POWER OFF AT THE CIRCUIT BREAKER
BEFORE INSTALLING THE SENSOR.
TighteningNut
TighteningNut Fixture
Wall
Lens Assembly
FSP-211
Outside Fixture Wall
Inside FixtureWall
RubberGasket
RubberGasket
Note: The Outside Fixture Wall thickness should be no greater than 0 .125” (3 .18mm) for optimal sensor mounting and security .
* Note: The FSP-211 must be grounded to ensure signal integrity, not for safety ground .
Outdoor Use at the exposed Sensor Collar part only when installed at the specific location per Installation
Instructions with a Listed Outdoor Enclosure.
INSTALLATION
30
30
20
10
10
20
0
8
0
10 0
0 33 77 1111 2222
10 2020
44 ft
Coverage Top View
Coverage Top View
Coverage Top View
Coverage Side View
Coverage Side View
Coverage Side View
2.33" / 5.92 cm
.78" / 1.97 cm
2.33”59.2mm
0.78”19.7mm
FSP-L4: 360° CoverageThe FSP-L4 is designed for mounting at heights between 30’ to 40’ . Its coverage area can be up to 60’ in diameter when mounted at 40’ .
COVERAGE PATTERN
Density and range of the coverage pattern is determined by the type of lens and mounting height .
FSP-L2: 360° CoverageThe FSP-L2 lens provides a 44’ diameter coverage area when mounted at a height of 8’ .
FSP‑L3 High Densi ty/Reduced Range Lens
FSP‑L2 Low Densi ty/Wide Range Lens
03 9636912 12
10
20
0
15
5
151820 15 18 20
20 10 0 10 20
0
20
10
10
20
40 ft
2.33”59.2mm
0.78”19.7mm
30
30
20
10
10
20
0
8
0
10 0
0 33 77 1111 2222
10 2020
44 ft
FSP‑L4 40 Foot High Bay Lens
0 6 12 3061230 20 20
0
10
20
30
40
0 3 6 12 2730
36122730
20 20
036
36
12
27
30
12
27
20
20
60 ft
3.2”81.3mm
0.93”23.6mm
FSP-L3: 360° CoverageThe FSP-L3 has a high density lens that covers a 40’ diameter area at a height of 20’ .
WIRING A SINGLE SENSOR
Non-DimmingDriver
LIN
EN
EU
TRA
L
NEUTRAL
LOAD
* GROUND
Occupancy Sensor
5E4
800.879.8585www.wattstopper.com
1519
5r1
LOA
D
LIN
E
NEU
T(v
iole
t)
(gre
y)
18-20 AWG Solid CU Wire Only
230 VAC, 50 Hz1200W max ballast
FSP-211
GRN
D
DIM
-
DIM
+
14-18 AWG Solid CU Wire Only
High/Low PIR
Non-Dimming Driver
DimmingDriver
LIN
EN
EU
TRA
L
NEUTRAL
*GROUND
GRAY (-)
VIOLET (+)
LOAD
Occupancy Sensor
5E4
800.879.8585www.wattstopper.com
1519
5r1
LOA
D
LIN
E
NEU
T(v
iole
t)
(gre
y)
18-20 AWG Solid CU Wire Only
230 VAC, 50 Hz1200W max ballast
FSP-211
GRN
D
DIM
-
DIM
+
14-18 AWG Solid CU Wire Only
High/Low PIR
Dimming Driver
1 . Determine an appropriate mounting location inside the light fixture . Allow a minimum distance of 0 .2” (5 .1mm) from the wiring end of the sensor to the wall of the fixture .
2 . Drill a hole 1 .30” (33 .0mm) in diameter through the sheet metal in the bottom of the fixture .
3 . Add the rubber gasket to the threaded collar, and install the sensor face down, parallel to the mounting surface . Ensure the rubber gasket touches the inside surface of the fixture . Install the plastic nut securely against the fixture to a torque of 25-30 in-lbs to ensure IP rating is maintained .
4 . Align the locking features between the sensor and lens module and push the lens module forward until the o-ring seals firmly . Turn the lens module clockwise to ensure it locks in place .
5 . Connect load and supply wires as shown in wiring diagram .6 . Restore power from the circuit breaker .
CAUTION TURN THE POWER OFF AT THE CIRCUIT BREAKER
BEFORE INSTALLING THE SENSOR.
TighteningNut
TighteningNut Fixture
Wall
Lens Assembly
FSP-211
Outside Fixture Wall
Inside FixtureWall
RubberGasket
RubberGasket
Note: The Outside Fixture Wall thickness should be no greater than 0 .125” (3 .18mm) for optimal sensor mounting and security .
* Note: The FSP-211 must be grounded to ensure signal integrity, not for safety ground .
Outdoor Use at the exposed Sensor Collar part only when installed at the specific location per Installation
Instructions with a Listed Outdoor Enclosure.
INSTALLATION
30
30
20
10
10
20
0
8
0
10 0
0 33 77 1111 2222
10 2020
44 ft
Coverage Top View
Coverage Top View
Coverage Top View
Coverage Side View
Coverage Side View
Coverage Side View
Coverage Side View
44'
FSP-211 COMMISIONING
The commissioning process establishes the appropriate param-eters for the FSP-211 operation . This is done through the use of the FSIR-100 commissioning tool . If no commissioning steps are taken, the sensor will use its default parameter values .
USING THE FSIR-100 PROGRAMMING TOOL
The FSIR-100 Wireless IR Programming Tool is a handheld tool for setup and testing of WattStopper FSP-211 .It provides wireless access to the FSP-211 sensors for setup and parameter changes .
The FSIR-100 display shows menus and prompts to lead you through each process . The navigation pad provides a familiar way to navigate through the customization fields .
Within a certain mounting height of the sensor, the FSIR-100 allows modification of the system without requiring ladders or tools; simply with a touch of a few buttons .
OPERATION
The FSIR-100 IR transceiver allows bi-directional communication between the FSP-211 and the FSIR-100 programming tool . Simple menu screens let you see the current status of the system and make changes . It can change FSP-211 sensor parameters such as high/low mode, sensitivity, time delay, cut off and more . With the FSIR-100 you can also establish and store FSP-211 parameter profiles .
BATTERIES
The FSIR-100 operates on three standard 1 .5V AAA Alkaline batteries or three rechargeable AAA NiMH batteries . The battery status displays in the upper right corner of the display . Three bars next to BAT= indicates a full battery charge . A warning appears on the display when the battery level falls below a minimum acceptable level . To conserve battery power, the FSIR-100 automatically shuts off 10 minutes after the last key press .
NAVIGATION
You navigate from one field to another using (up) or (down) arrow keys . The active field is indicated by flashing (alternates between yellow text on black background and black text on yellow background .
Once active, use the Select button to move to a menu or function within the active field . Value fields are used to adjust parameter settings . They are shown in “less-than/greater-than” symbols: <value> . Once active, change them using(left) and(right) arrow keys . In general the up key increments and the down key decrements a value . Selections wrap-around if you continue to press the key beyond maximum or minimum values . Moving away from the value field overwrites the original value . The Home button takes you to the main menu . The Back button can be thought of as an undo function . It takes you back one screen . Changes that were in process prior to pressing the key are lost .
FSP-201FSP-211FD-101FD-301
Home/MainMenu
Up
Select
DownRight/NextLeft
Back
PowerOn/Off
BAT=
IR COMMUNICATION
IR communication can be affected by the mounting height of the sensor and high ambient lighting such as direct daylight of electric light such as floodlights, and some halogen, fluorescent lamps, LED’s .
When trying to communicate with the FSP-211, be sure to be positioned under the sensor without any obstructions . Every time the programming tool establishes communication with the FSP-211, the controlled load will cycle .
• If communication is not successful, (if possible) move closer to the sensor .
• If still not successful, there may be too much IR interference from other sources . Programing the unit at night when there is no daylight available may be the only way to communicate with the sensor .
15'-30'
* Distance may vary depending on the lighting environment
FSP-211 COMMISIONING
The commissioning process establishes the appropriate param-eters for the FSP-211 operation . This is done through the use of the FSIR-100 commissioning tool . If no commissioning steps are taken, the sensor will use its default parameter values .
USING THE FSIR-100 PROGRAMMING TOOL
The FSIR-100 Wireless IR Programming Tool is a handheld tool for setup and testing of WattStopper FSP-211 .It provides wireless access to the FSP-211 sensors for setup and parameter changes .
The FSIR-100 display shows menus and prompts to lead you through each process . The navigation pad provides a familiar way to navigate through the customization fields .
Within a certain mounting height of the sensor, the FSIR-100 allows modification of the system without requiring ladders or tools; simply with a touch of a few buttons .
OPERATION
The FSIR-100 IR transceiver allows bi-directional communication between the FSP-211 and the FSIR-100 programming tool . Simple menu screens let you see the current status of the system and make changes . It can change FSP-211 sensor parameters such as high/low mode, sensitivity, time delay, cut off and more . With the FSIR-100 you can also establish and store FSP-211 parameter profiles .
BATTERIES
The FSIR-100 operates on three standard 1 .5V AAA Alkaline batteries or three rechargeable AAA NiMH batteries . The battery status displays in the upper right corner of the display . Three bars next to BAT= indicates a full battery charge . A warning appears on the display when the battery level falls below a minimum acceptable level . To conserve battery power, the FSIR-100 automatically shuts off 10 minutes after the last key press .
NAVIGATION
You navigate from one field to another using (up) or (down) arrow keys . The active field is indicated by flashing (alternates between yellow text on black background and black text on yellow background .
Once active, use the Select button to move to a menu or function within the active field . Value fields are used to adjust parameter settings . They are shown in “less-than/greater-than” symbols: <value> . Once active, change them using(left) and(right) arrow keys . In general the up key increments and the down key decrements a value . Selections wrap-around if you continue to press the key beyond maximum or minimum values . Moving away from the value field overwrites the original value . The Home button takes you to the main menu . The Back button can be thought of as an undo function . It takes you back one screen . Changes that were in process prior to pressing the key are lost .
FSP-201FSP-211FD-101FD-301
Home/MainMenu
Up
Select
DownRight/NextLeft
Back
PowerOn/Off
BAT=
IR COMMUNICATION
IR communication can be affected by the mounting height of the sensor and high ambient lighting such as direct daylight of electric light such as floodlights, and some halogen, fluorescent lamps, LED’s .
When trying to communicate with the FSP-211, be sure to be positioned under the sensor without any obstructions . Every time the programming tool establishes communication with the FSP-211, the controlled load will cycle .
• If communication is not successful, (if possible) move closer to the sensor .
• If still not successful, there may be too much IR interference from other sources . Programing the unit at night when there is no daylight available may be the only way to communicate with the sensor .
15'-30'
* Distance may vary depending on the lighting environment
Typical Sensor Coverage
0’
0’
8’
9’
10’5’ 20’ 25’15’10’ 5’20’25’ 15’
12.5’
0’
25’
12.5’
25’
0’
0’
8’
9’
10’5’ 20’ 25’15’10’ 5’20’25’ 15’
12.5’
0’
25’
12.5’
25’
Radio and motion sensor details
- Motion sensor coverage can be adjusted from a narrow to a wide (25' radius) detection range, which helps reduce false triggers to further increase energy savings.
- 1.8 Watts max (no load draw)
- Operating voltage 120-277 VAC RMS
- Communicates using the ZigBee protocol
- Carries out dimming commands from Gateway
- Reports ambient light readings to 1500 Ft-Cd
- Transmission Systems Operating within the band 2400-2483.5Mhz
- Motion sensor coverage can be adjusted from a narrow to a wide (25' radius) detection range, which helps reduce false triggers to further increase energy savings.
- Sensing profiles can be updated to adapt to activity levels in the environment, such as occupancy level, wind, and mounting height.
- ROHS Compliant
SFC & SFCR SlenderForm LED luminaire
Garage & Canopy - Canopy Mount
Specifications
General Description
Each Gardco SlenderForm luminaire is a ceiling surface, ceiling pendant or recessed mounted ceiling / canopy / garage luminaire featuring LEDs mounted in a fixed array. Internal components are totally enclosed in a rain-tight, dust-tight and corrosion resistant housing. Luminaires are suitable for wet locations.
Housing
Rugged extruded aluminum housing body with an integral LED thermal management system, with die cast aluminum end caps.
Surface Mounted Luminaires - Quick mount plate and mounting
A die formed 14 ga. galvanized steel plate is supplied for mounting to a recessed, surface, or rigid pendant hung 4" (10.16 cm) j-box (standard j-box and rigid pendant by others). All pendants, including rigid pendants and swivel pendants are supplied by others.
Caution: Gardco is not responsible for failure of mounting components supplied by others. Proper care should be exercised in mounting component selection to ensure adequate luminaire support, given luminaire weight, vibration potential and thermal conditions present in the application. If luminaires are supported solely by screws into a composite j-box, additional support directly to structure is recommended.
Recessed Mounted Luminaires
SFCR luminaires are provided with a recessed mounting kit for installation in a drywall ceiling which includes a wood support structure. SFCR luminaires are not suitable for installation in a grid ceiling. Mounting kit includes a flush trim assembly. Installation can be performed from above or below the ceiling. The mounting kit has adjustable supports that mount to wooden support beams, capable of adjustement from a minimum 20" to a maximum 23.4" spacing.
SFCR luminaires are rated non-IC and require a minimum 3" clearance from insulation in all directions. The bottom of the luminaire will be approx. 1" below the ceiling after installation. SFCR recessed mount luminaires are NOT available with 900mA, MR, PCB, BX or JB.
LED Module
48 high power LEDs. Metal core printed circuit board. LEDs tested by ISO 17025-2005 accredited lab in accordance with IESNA LM-80 guidelines extrapolations in accordance with IESNA TM-21. IP66 sealed light engines designed and tested to rating IK10 in accordance with European standard EN 62262 (equivalent of international standard IEC 62262 2002). RoHS compliant. Color temperatures per ANSI/NEMA bin Warm White 3000K nominal (3045 +/- 175K), Neutral White 4000 Kelvin nominal (3985 +/- 250K), or Cool White 5700K nominal (5667 +/- 355K). CRI 70 min.
Electrical
Luminaires are equipped with an LED driver system that accepts 120V through 277V, 50hz to 60hz, (UNIV), or a driver that accepts 347V or 480V input. Power factor is not less than 90%. Optional 0-10V dimming to 10% power. RoHS compliant. Surge protector standard and is in accordance with IEEE / ANSI C62.41.2 guidelines, with a surge current rating of 10kA.
Optical Systems
The Type 3 optic is an LED array providing an IES Type III distribution. The Type 5 optic is an LED array providing an IES Type V, wide distribution. The Type 5R optic is an LED array providing an IES Type V distribution, in a rectangular pattern. The concentrated downlight (CD) optic is an LED array that provides a circular pattern of concentrated light directly below the luminaire.
Finish
Each luminaire receives a fade and abrasion resistant, electrostatically applied, thermally cured, triglycidal isocyanurate (TGIC) textured polyester powdercoat finish. Standard color is Medium Gray paint.
LED Thermal Management
The housing design provides integral extruded aluminum thermal radiation fins to provide the excellent thermal management so critical to long LED system life.
IP Rating
SlenderForm luminaires are IP65 rated with dedicated IP66 rated LED modules. Optional GL Glass Lens assembly available when tempered glass lens is required.
Controls
Motion Response luminaires (MR) include a passive infrared (PIR) motion sensor (WattStopper FSP-211 equipped with an FS-L2W lens) capable of detecting motion within 22 feet of the sensor, 360° around the luminaire, when placed at an 8-12 foot mounting height. Available in 120V to 277V input only. Motion sensor off state power is 1 watt. In Motion Response luminaires, when no motion is detected for 10 minutes, the Motion Response system reduces the wattage by 80%, to 20% of the normal constant wattage per RP-20, reducing the light level accordingly. When motion is detected by the PIR, the luminaire returns to full wattage and full light output. Includes a daylight sensor which enables daylight harvesting. Wireless Remote Programming tool available (FSIR-100) for field programming (ordered separately).
Listings
cULus Listed for Canada and USA. Entire luminaire is rated for operation in ambient temperatures from -40° (-40°F) to +40°C (+104°F). SFC and SFCR luminaires are DesignLights Consortium qualified when ordered with CW or NW LED color temperature. WW option does not meet DLC.
Limited Warranty
5 year limited warranty. See signify.com/outdoorluminaires for complete details and exclusions. Predicted Lumen Depreciation Data
Ambient Temperature °C
System Current
Calculated L70hrs 1,2
L70 per TM21 2,3
Lumen Maintenance @ 60,000hrs
25 °C 900 mA >100,000 >60,000 97%
1. Predicted performance derived from LED manufacturer's data and engineering design estimates, based on IESNA LM-80 methodology. Actual experience may vary due to field application conditions.
2. L70 is the predicted time when LED performance depreciates to 70% of initial lumen output.3. Calculated per IESNA TM 21-11. Published L70 hours limited to 6 times actual LED test hours.
© 2019 Signify Holding B.V. All rights reserved. Signify reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication.
SlenderForm_SFC_LED 12/18 page 4 of 4
Signify, North America Corp., 200 Franklin Square Drive, Somerset, NJ 08873 Tel. 855-486-2216
Signify, Canada Ltd., 281 Hillmount Rd, Markham, ON, Canada L6C 2S3 Tel. 800-668-9008
SFC & SFCR SlenderForm LED luminaire
Garage & Canopy - Canopy Mount
www.gardcolighting.com