Diopsys® mfERG vision tests provide objective information about localized retinal function to help recognize the first signs of drug-induced retinopathy. 1-2 In some cases, retinal dysfunction may occur before structural abnormalities, requiring a robust functional testing method to detect retinal toxicity early. 2-4 • Monitor retinal function loss and recovery with objective, quantitative metrics 2-3 • Co-manage patients more efficiently for more timely changes to treatment • Clearly defined waveforms. • Mostly white to lighter blue sectors. • Ring ratio data within expected ranges.* Conclusion: Suggests good retinal function. In this case, the eye care provider scheduled a follow-up to retest in one year. • Atypical waveforms. • Darker blue to black sectors. • Ring ratios outside expected ranges.* Conclusion: Suggests poor retinal function. In this case, the eye care provider notified prescribing physician with suggestion to stop medication immediately to prevent further damage, unless medically critical. The Diopsys® NOVA™ is an electrophysiology device that generates photic stimuli, and records, processes, and analyzes the resultant signals to provide information about the visual system. Diopsys Vision Testing Systems are FDA 510(k) cleared; carry the CE mark; and are IEC 60601 Certified. *Data on file with Diopsys, Inc. © Diopsys, Inc. 2018. All Rights Reserved. Gain an objective look at localized retinal dysfunction. Healthy Eyes Plaquenil Toxicity objective functional accessible

Upload: others

Post on 15-Sep-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Gain an objective look at localized retinal dysfunction.ww1.prweb.com/prfiles/2018/04/11/15406616/Diopsys mfERG...2018/04/11  · The Diopsys® NOVA is an electrophysiology device

Diopsys® mfERG vision tests provide objective information about localized retinal function to help recognize the first signs of drug-induced retinopathy.1-2 In some cases, retinal dysfunction may occur before structural abnormalities, requiring a robust functional testing method to detect retinal toxicity early.2-4

• Monitor retinal function loss and recovery with objective, quantitative metrics2-3

• Co-manage patients more efficiently for more timely changes to treatment

• Clearly defined waveforms.

• Mostly white to lighter blue sectors.

• Ring ratio data within expected ranges.*

Conclusion: Suggests good retinal function. In this case, the eye care provider scheduled a follow-up to retest in one year.

• Atypical waveforms.

• Darker blue to black sectors.

• Ring ratios outside expected ranges.*

Conclusion: Suggests poor retinal function. In this case, the eye care provider notified prescribing physician with suggestion to stop medication immediately to prevent further damage, unless medically critical.

The Diopsys® NOVA™ is an electrophysiology device that generates photic stimuli, and records, processes, and analyzes the resultant signals to provide information about the visual system. Diopsys Vision Testing Systems are FDA 510(k) cleared; carry the CE mark; and are IEC 60601 Certified.*Data on file with Diopsys, Inc. © Diopsys, Inc. 2018. All Rights Reserved.

Gain an objective look at localized retinal dysfunction.

Healthy Eyes Plaquenil Toxicity

• objective • functional • accessible

Page 2: Gain an objective look at localized retinal dysfunction.ww1.prweb.com/prfiles/2018/04/11/15406616/Diopsys mfERG...2018/04/11  · The Diopsys® NOVA is an electrophysiology device

To learn more, visit Diopsys.com/multifocal or call 1-973-244-0622.

1. Hood, DC, et al. ISCEV Standard for clinical multifocal electroretinography (2011 edition). Doc Ophthalmol 124:1–13. 2. Dettoraki M, Moschos MM. The Role of Multifocal Electroretinography in the Assessment of Drug-Induced Retinopathy: A Review of the Literature. Ophthalmic Res 2016;56:169–177. 3. Talamini CL, et al. Abnormal multifocal ERG findings in patients with normal-appearing retinal anatomy. Doc Ophthalmol 2011;123(3):187-192. 4. Marmor, M, et al. Recommendations on Screening for Chloroquine and Hydroxychloroquine Retinopathy (2016 Revision). Ophthalmology 2016;123:6:1386-1394. 5. Hansen, MS, et al. Ophthalmic Pearls: Hydroxychloroquine-Induced Retinal Toxicity. EyeNet June 2011:33-35.

Diopsys, Inc. • 16 Chapin Road, Suite 911-912 • Pine Brook, NJ 07058 • (973) 244-0622 • www.diopsys.comCopyright © Diopsys, Inc. 2018. All Rights Reserved. mfERGLEAVEBEHIND03012018

Detect developing toxicity early.2-4

Enhance co-management.

The American Academy of Ophthalmology (AAO) recommends the use of multifocal electroretinography for chloroquine (CQ) and hydroxychloroquine (HCQ) retinopathy screening.4

Most ocular side effects of drug-induced toxicity are reversible after cessation of therapy if detected early.2 However, taking a patient off certain medications can be life altering.

Multifocal ERG test results can help eye care providers1-5

• Confirm dysfunction when visual fields are abnormal

• Support continuation of medication when test results show healthy retinal function

• objective • functional • accessible