TABLE OF CONTENTS
1. INTRODUCTION (Pg 4)
2. SAFETY PRECAUTIONS
3. SYSTEM REQUIREMENTS
4. WHAT’S IN THE BOX
5. G-SPEED eS OVERVIEW (Pg 5)
6. OPTIONAL G-TECH PCIe RAID CONTOLLER OVERVIEW 7. G-SPEED eS AUDIBLE ALARMS (Pg 6)
8. SETTING UP G-SPEED eS WITH THE G-TECH PCIe RAID
CONTROLLER (Pg 6)
9. SETTING UP G-SPEED eS USING THE WEB GUI (Pg 12)
10. CONFIGURING TWO G-SPEED eS UNITS IN RAID 5 MODE (Pg 16)
11. WHAT TO DO IN THE EVENT OF A DISK DRIVE FAILURE (Pg 19)
12. TECHNICAL SUPPORT/LIMITED WARRANTY (Pg 20)
APPENDIX A – DETAILED INFORMATION ON USING THE WEB GUI APPENDIX B – EXPLANATION OF RAID LEVELS APPENDIX C – NOTES APPENDIX D – FORMATTING G-SPEED USING DISK MANAGEMENT
Page 1
G-SPEED eS INSTALLATION GUIDE - Windows
Page 2
G-SPEED eS INSTALLATION GUIDE - Windows
Page 3
G-SPEED eS INSTALLATION GUIDE - Windows
1. INTRODUCTION Thank you for purchasing G-SPEED eS from G-Technology, Inc. (G-Tech)! Specifically designed for professional content creation applications, G-SPEED eS features a high-speed 3Gbit/sec eSATA interface and when used in conjunction with the optional G-Tech PCI Express (PCIe) RAID controller provides RAID 0, 1, 5, 10 and JBOD functionality with greater than 2TB support in Windows 32bit environments. Up to four G-SPEED eS units can be attached to the G-Tech RAID controller for storage capacities to 16 TB and data rates over 600 MB/sec. G-SPEED eS supports multi-stream video editing workflows.
2. SAFETY PRECAUTIONS The disk drives contained in your G-SPEED eS are delicate electronic instruments and are susceptible to damage due to excessive physical shock. Place the unit in a vented area away from moisture or liquids. Please handle the unit with care. Do not open the case. Doing so will void the warranty. If the Product is returned with damage caused by improper handling, the warranty will be void and liability will rest with the user.
3. SYSTEM REQUIREMENTS
• PCIe equipped workstation • Microsoft Windows 2000/XP/2003/Vista • G-Tech PCIe RAID Controller or third party port multiplier
aware eSATA host adapter
Optional G-Tech 4-port, PCIe x4 RAID Controller
4. WHAT’S IN THE BOX
Take a moment to ensure that the following items are included in the box. If anything is missing, please call G-Tech at (310) 449-4599. Please keep the shipping container and packing materials. In the unlikely event that you need to return G-SPEED eS to us for any reason, you must use the G-Tech shipping container. If the Product is returned damaged caused by improper packaging, the warranty will be void and liability will rest with the user.
• G-SPEED eS storage system • 4 removable SATA drive modules (installed in unit) • (2) disk module keys • 1-meter eSATA cable • AC Power cable • Optional – G-Tech PCIe RAID controller • Configuration Utility & Installation CD
Page 4
G-SPEED eS INSTALLATION GUIDE - Windows
Page 5
5. G-SPEED eS OVERVIEW
6. OPTIONAL G-TECH PCIe RAID CONTOLLER OVERVIEW
The optional G-Tech PCIe RAID controller connects G-SPEED eS to your PCIe equipped workstation and provides RAID 0, 1, 5, 10 & JBOD functionality. You will choose your level of RAID protection when you set up the G-SPEED eS in Section 8. For an explanation of supported RAID levels, please refer to Appendix B.
G-SPEED eS is also compatible with third-party Windows port multiplier aware eSATA host adapters. Refer to your host adapter documentation to set up G-SPEED eS with these boards.
PCIe x4 interface RAID Engine
(4) High-speed 3 Gb/s eSATA ports. Supports up to (4) G-SPEED eS systems
(4) Removable Disk Drive Modules
Drive Module Power/Activity
LED
Temperature/Fan RPM Warning LED
Power Supply LED
Disk Module Lock Hole
ON/ OFF Switch
Remo
AC Input
vable Fan
3 GB/sec eSATA Port
Cable Lock Hole
G-SPEED eS INSTALLATION GUIDE - Windows
Page 6
7. G-SPEED eS AUDIBLE ALARMS 7.1 The G-SPEED eS enclosure is equipped with an audible
alarm that sounds when:
1. The internal temperature of the G-SPEED eS enclosure reaches a temperature of 60° centigrade
and/or
2. When the main FAN fails or the RPM of the fan slows to a state where the fan can longer adequately cool the system.
In addition to the audible alarm, the Temperature/Fan Warning LED located on the front bezel of G-SPEED eS will illuminate.
If you hear an audible alarm and see the RED warning LED on the front of G-SPEED eS, stop using G-SPEED eS immediately. Check to see if the fan is spinning and move the unit to a cooler location. If the problem persists, contact G-Tech Support.
7.2 The G-Tech RAID controller is also equipped with an
audible alarm that sounds when:
1. A disk drive failure occurs
or
2. When the G-SPEED eS is removed from the RAID controller without first selecting “Unplug” in the Array Maintenance menu in the web GUI.
If you hear an audible alarm coming from the G-Tech RAID controller, see Section 11 “What to do in the Event of a Disk Drive Failure”. See Appendix B.1.7.2 for information on the proper way to hot “Unplug” G-SPEED eS.
8. SETTING UP G-SPEED eS WITH THE G-TECH PCIe RAID CONTROLLER Connecting G-SPEED to your workstation and configuring your system takes just a few steps as outlined below. For this example we will be installing G-SPEED eS on a Windows XP system. The installation is similar for Windows 2000, 2003 and Vista.
8.1 Installing the G-Tech PCIe RAID Controller
1. Install the G-Tech RAID controller into an available PCIe slot in your workstation.
2. Secure the RAID controller in place.
G-SPEED eS INSTALLATION GUIDE - Windows
8.2 Attaching G-SPEED eS to the G-TECH RAID Controller 1. Attach one end of the supplied eSATA cable to the eSATA
port located on the back of G-SPEED eS.
2. Attach the other end of the eSATA cable to Port 1 (port closest to motherboard) on the G-Tech RAID controller as shown below.
3. Attach the power cord to the back of G-SPEED eS and connect the other end to AC power.
4. Power on G-SPEED eS.
8.3 Installing the G-Tech PCIe RAID Controller Software There are three steps required to fully install the software
for the G-SPEED eS Controller.
1. Install the Windows driver 2. Update the Controller firmware 3. Installing the web GUI
Check for software updates at http://www.g-technology.com/Support/
1. Install the G-SPEED eS Windows driver a. Power on the workstation b. Insert the G-Tech Product CD into the CD-ROM drive
When the CD loads a welcome screen may appear. Close this window.
c. When the system boots the “Found New Hardware Wizard” will appear. Select “Install from a list or specific location” and click <Next>.
Page 7
G-SPEED eS INSTALLATION GUIDE - Windows
d. Select “Don’t Search, I will choose the driver to install” and click <Next>.
e. Click <Have Disk>.
f. Click on the <Browse> Button and navigate to the CD-ROM drive containing the G-Tech Product CD. Continue to “\Manuals-Drivers\G-SPEED eS\PC\GSeS Driver Win-v1.0\” Select the folder for your operating system and click <OK>.
g. Select “G-SPEED eS RAID Controller and click <Next>.
Page 8
G-SPEED eS INSTALLATION GUIDE - Windows
h. When the Windows Logo warning screen appears click <Continue Anyway>.
i. The RAID controller driver will install and the Wizard will complete. Click <Finish>.
j. A new “Found New hardware Wizard” will open for the “G-Tech RCM device.” Click <Next>.
k. As before, click on “Don’t search. I will choose the driver to install.”
Page 9
G-SPEED eS INSTALLATION GUIDE - Windows
l. Select “G-SPEED es RAID Controller” and click <Next>.
m. The RCM Device driver will install and the Wizard will complete. Click <Finish>. This completes the driver installation.
n. Remove the G-Tech Product CD. o. Restart your workstation.
2. Update the G-SPEED eS Controller firmware
a. Insert the G-Tech Product CD into the CD-ROM / DVD drive. When the disk loads a welcome screen should appear. Click on the <Manuals / Drivers> link.
NOTE: If the Menu screen does not appear, the “autorun” feature may not be enabled on your workstation. To load the menu manually go to the START menu and click on “Run.” Enter the drive letter of your CD-ROM containing the Product CD and then “autorun.exe.” For example “D:\autorun.exe”
b. This will open Windows Explorer. Navigate to the “G-SPEED eS\PC\GSeS Firmware-v2.2c” folder. Double-click “hptflash.exe” to launch the flash utility.
Page 10
G-SPEED eS INSTALLATION GUIDE - Windows
c. Click <Open...>.
d. Select “rr231.xpm.22c” and click <Open>.
e. Click <Flash!> to begin the update process.
f. When the process is completed click <OK>.
g. Remove the G-Tech Product CD. h. Restart your workstation.
3. Installing the G-SPEED eS Web GUI.
a. Insert the G-Tech Product CD. When the disk loads a welcome screen should appear. Click on the <Manuals / Drivers> link.
Page 11
G-SPE
b
c
d
EED eS INSTA
b. Navigate to t“Manuals-DrDouble click instructions,
. When the ins
. The Web GU
your G-SPEE
ALLATION G
the folder: ivers\G-SPEED on “Setup.exe” accepting the
stallation is com
I is ready to beED eS.
UIDE - Windo
eS\PC\GSeS W” and follow thedefaults.
mplete click <F
e launched and
ows
WEB GUI-vX.X” e onscreen
inish>.
configure
9. SET
TmaeG
wsd
9.
1
2
TTING UP G-SThe G-Tech RAImonitor the G-any web browequivalent. TG-SPEED eS on
NOTE: Wbuilt-in lim(2048GB).
with a new technolsize presented to thdisks of up to 16TB
1 Accessing th
1. Open your w
https:/
2. The followin<YES> butt
NOTE: save th
SPEED eS USINID controller wSPEED eS systwser such asThis section wn a Windows wo
indows 2000 / XPmitation that logic. The G-SPEED eSogy, Variable Sectohe operating syste
B.
he G-Tech PC
web browser an
//localhost:74
ng Security Aleton.
For easy access toe web address in y
NG THE WEB Gweb GUI is usedtem. The GUI s Safari, Interwill describe hoorkstation.
P are 32 bit opercal disks cannot S RAID Controller oor Size (VSS). VSm making it possib
Ie RAID Cont
nd enter the fol
402
ert window will
o the G-SPEED eS Wyour favorites
Page
GUI d to configure ais accessed usrnet Explorer ow to setup
rating systems witbe greater than overcomes this bar
SS increases the seble to now have log
roller Web GU
llowing address
appear. Click
Web GUI
e 12
and sing
or the
th a 2TB rrier
ector gical
UI
s:
the
G-SPE
3.
EED eS INSTA
Enter “adminas the Passwo
Note: Sechanging
ALLATION G
n” as the User Nord and click on
ee appendix A.4. the password.
UIDE - Windo
Name and “000n the <Login>
5 for instructions
ows
00” (four zerosbutton.
s on
s) 4.
The main scrbelow. Each othe “Physical
Note: Tformattand reworksta
NOTE: features
reen of the weof the four drivDevice Informa
The G-SPEED eS ised for Mac OSX. Te-created to funation. Section 9.2
Please refer to APPs of the G-Tech RA
eb GUI will apves in the unit aation” section o
s shipped initializeThis configuration
nction correctly covers this process
PENDIX A for detailID Controller web
Page
pear as shownare displayed inof the GUI.
d as a RAID 0 arra needs to be deleteon your Windows.
led information on GUI.
e 13
n n
ay ed ws
the
G-SPE
9.2 CTcofob
1.
2.
EED eS INSTA
Configuring thhe G-SPEED eSonfigured in RAor an explanatioelow to setup t
Launch the G-T
Click on the “Mbelow will appMaintenance W
ALLATION G
he RAID level S/G-Tech RAID AID 0, 1, 5, 10 on of RAID levethe system
Tech RAID Con
Maintenance” Liear. Click on <
Window.
UIDE - Windo
of G-SPEED econtroller comband JBOD. (Seels) Follow the
troller web GUI
ink and the win<Delete> in the
ows
eS bination can beee Appendix B directions
I.
ndow shown e Array
e 3
4
3. Click the <O
W
sto
4. The GUI wi
the <Createappear.
OK> button to p
WARNING: This wilored on G-SPEED e
ll refresh and e Array> butto
proceed.
l delete any data eS!
the array is non. The “Create
Page
ow deleted. Ce Array” page
e 14
lick will
G-SPE
5.
EED eS INSTA
The Create Aarray and all ita RAID 0 arraselect it from Select RAID “Array Name”
NOTE: In thsystem can aselecting the
NOTE: When the initializaapproximate
ALLATION G
rray page is wts parameters. ay. (To set up the dropdown
0 for “Array T
his example we arealso be set up in Re appropriate settin
n creating redundaation process takesly 1hr 45m per TB
UIDE - Windo
where you con In this examp
p a different RAn menu labeled
Type”, enter G
creating a RAID 0RAID 1, 5, 10 or JBOng in the “Array Ty
nt arrays (RAID 1 s time. For RAID 5 of final capacity.
ows
nfigure the neple we will setuAID level simpd “Array Type.”
G-SPEEDeS fo
array. The OD mode by
ype” pull-down.
or RAID 5) it takes
w up ly ”)
or
6.
7.
8.
o(s
. Click the <Searray.
. To create an
enter the val
. If you are cre
choose the vindicated in t
NOTE: Wwith a buithan 2TB
overcomes this ba(VSS). VSS incresystem making it p
Arr
Up
2TB
4TB
8TB
elect All> to qu
array less thanue in MB in the
eating an arrayvalue for Variabthe table below
indows 2000 / XPlt-in limitation tha (2048GB). Therrier with a new t
eases the sector sossible to now hav
ray Capacity S
to 2TB
B -> 4TB
B -> 8TB
B -> 16TB
uickly select all
n the maximume Capacity field
y of Greater thale Sector Size a
w.
P are 32 bit opert logical disks can
e G-SPEED eS RAtechnology, Variabsize presented to ve logical disks of u
Sector Size
512
1k
2k
4k
Page
the disks for th
m available, .
an 2TB, as
rating systems not be greater AID Controller ble Sector Size
the operating up to 16TB.
e 15
he
G-SPE
9.
10.
11.
12.
EED eS INSTA
Click <OK> on
. Click the <Crinitialize. A pbeen create
. The GUI will rcompleted init
NOTE: Wh the initiali
approxima . Your G-SPEEDwith your opdetailed instrformat the G-S
ALLATION G
n the warning m
reate> button popup will apped and is no
reload indicatinializing the RAI
hen creating redunzation process takeately 1hr 45m per T
D eS is now reaperating systemuctions on usSPEED eS for W
UIDE - Windo
message that a
and the arrapear confirmingw initializing.
ng that the G-SID 0 array.
ndant arrays (RAID es time. For RAID TB of final capacity
ady to be formm. See Appsing Disk Ma
Windows XP.
ows
ppears.
ay will begin tg the array ha
Click <OK>
SPEED eS has
1 or RAID 5) 5 it takes y.
matted for use pendix D for nagement to
to as >.
10. CFa
CONFIGURINGFollow the direarrays in RAID
1. Ensure thainstalled an
2. Attach bothcontroller ayour compu
3. Launch thetwo units awill display
G TWO G-SPEEections below 5 mode using t
t the G-Tech RAnd the driver an
h G-SPEED eS uas shown belowuter
e G-Tech RAID attached to the y information lik
ED eS UNITS Ito configure
the G-Tech RAI
AID controller ind web GUI are
units to the G-Tw, power the un
Controller we G-Tech RAID cke that shown b
Page
IN RAID 5 MOtwo G-SPEED D controller.
s properly e loaded.
Tech RAID nits and restart
b GUI. With controller, the Gbelow.
e 16
ODE
eS
the GUI
G-SPE
4. CN
5. C
w
6. C
7. R“D
EED eS INSTA
Click on the “MName” GS Disk
Click the <Delewill appear.
WARNstored
Click the <OK>
Repeat the pr“Maintenance” Disk 1_1. The
ALLATION G
aintenance” link 1_0. The win
ete> button. Th
NING: This will dele on G-SPEED eS.
> button to dele
rocedure for Glink next to twindow below
UIDE - Windo
k next to the adow shown bel
he following wi
ete any data
ete the array.
GS Disk 1_1. he array with will appear.
ows
array with “OS ow will appear.
ndow
Click on th“OS Name” G
he GS
8.
9.
Click the <appear.
lick the
C
<arrays havethe <Creatwindow will
Delete> button
WARNING: This stored on G-SPEE
<OK> button e now been dete Array> but appear.
n and the follo
will delete any datD eS.
to delete the eleted as showtton. The “C
Page
owing window
a
array. Both n below. Click Create Array”
e 17
will
G-SPEEED eS INSTA
10.
In this windowSelect RAID Enter G-SPEESelect Foregand Write BaClick <Select <Create> but
ALLATION G
w select the fol5 for “Array TyED-eS-R5 for “round for “Initack for “Cache All> button to tton to begin th
UIDE - Windo
lowing values ape:”, “Array Name:”, tialization Meth Policy:” select all diskshe initialization
ows
as shown:
od:”
s then click the process.
11
12
13
14
1. A popup wilcreated and
2. The GUI wilinitializing.
3. The RAID 545m per Tprocess is c5 and “Stat
4. Your G-SPEwith your oinstructions G-SPEED eS
l appear confirm is now initializ
l reload indicat
5 initialization pTB of final cacomplete, the Gus” as Normal
ED eS is now perating system on using DisS for Windows X
ming the array zing. Click <OK
ing that the G-
process takes apacity. Once
GUI will indicate.
ready to be fm. See Appensk ManagemenXP.
Page
has been K>.
SPEED eS is
approximately the initializate “Type” as RA
formatted for undix D for detaint to format
e 18
1hr tion AID
use iled the
G-SPE
11. WHTheafaire
Fo
1
2
3
EED eS INSTA
HAT TO DO INhe G-Tech RAIDach of the disk dilpure, an audiblort the failed
NOTE: If G(RAID 1, 5However, tdrive shoul
ollow the steps
1. Launch the
2. Mute the alabutton.
3. The GUI wiAn exclamathat the “Sportion of G-SPEED e
In this eto the Gconnecte
ALLATION G
THE EVENT O controller contdrives in G-SPEe alarm will soudrive and its ph
G-SPEED eS was co5 or 10), a drive fhe array is now in d be replaced as so
below to identi
web GUI.
arm by clicking
ll display inforation mark on tStatus” of the
the GUI indeS unit has faile
xample there are t-Tech RAID controed to Port 2 of the
UIDE - Windo
OF A DISK DRItinually monitoEED eS. In the und. The web hysical position
onfigured in a protfailure does not re an unprotected stoon as possible to
fy and replace
g on the <Beepe
mation like thathe G-SPEED e array is Criticates which
ed.
two G-SPEED eS unller. Drive 3 of the G-Tech RAID contr
ows
IVE FAILURE rs the health of event of a diskGUI will also
n.
tected RAID mode esult in data loss. tate and the failed avoid data loss.
a failed drive.
er Mute>
at shown beloweS icon indicateical. The lowedrive in whic
nits connected G-SPEED eS roller has failed.
f k
w. es er ch
4. Remove the fG-SPEED eS controller) byand gently slid
WARNdrive connefollowconne
REMO
LOSSON G
X
failed drive (In connected to
y inserting the pding the drive m
NING: Make absoindicated by the G
ected to the G-Tecw the cable to ensuected to on the RAI
OVING THE WRONS OF THE ARRAY A-SPEED eS.
n this exampleo port 2 of thprovided key inmodule out of t
lutely sure that yoGUI. If multiple G-h RAID controller, re you know which
ID controller.
NG DRIVE WILL RAND ALL OF THE
Page
e Drive 3, of the G-Tech RAn to the lock hothe enclosure.
ou remove the faile-SPEED eS units ar it is a good idea th Port # the array
RESULT IN THE CONTENT STORE
e 19
he ID ole
ed re to is
ED
G-SPE
5. RiiRT
6. O
N
12. TEC
Ifplfo
Wofav
EED eS INSTA
Replace the fain place. Oncendicate that tRebuilding anThe rebuild tim
Once the rebuilNormal and pr
CHNICAL SUPf y u encounto elease contact ollowing ways:
phonTele eFax: (310E-mail: sInternet:
When contactingf your computevailable:
• r G-S• atin You Oper g• Compute• eSATA ho• Amount o• Other dev
ALLATION G
led drive with the drive has he array is red the percentae is approxima
ld is complete, rotecting your v
PORT er any difficultG-Tech Techn
e: (310) 449-40) 449-4670 upport@g-tech http://www.g-
g Technical Super and have th
PEED eS serial g system and vr brand and mo
ost adapter branof memory instvices attached
UIDE - Windo
a new disk mospun up to spe
ebuilding (The age complete) ately 2 hours pe
G-SPEED eS isvaluable data o
ties while instical Support v
4599
hnology.com -technology.com
pport, make sue following info
number (on boversion odel nd and model alled to your comput
ows
odule and secureed, the GUI w“Status” show
as shown belower TB.
s back to nce again.
alling G-SPEEDvia one of th
m/support
re to be in fronormation readi
ottom of unit)
ter
re ill
ws w.
D, he
nt ly
13. LIGausGRortPasMtGboewG
FaG( ITRPDDITHTI
IMITED WARRG-Technology Iany defect in use, for the deshould becomeG-Tech, will at iRepair or replaon an exchanreconditioned. the Property of Product has beas a result of service is availaMaterial Authothe Product duG-Tech service bear all shippiother costs, eeffe te rectua pwarranty. All G-Tech in the o
For more informan RMA numbeG-Tech at 1653(310) 449-4599 IN THE EVENT THE WARRANTREMEDY SHALPROVIDED ABODAMAGES, INCDATA, ARISINGIMPLIED WARRTECH AND, TOHEREBY EXCLUTO THE EXTENTINJURY DAMAG
RANTY nc. (G-Tech) wmaterial and wesignated warre defective wits discretion, rcement parts onge basis an All replaced pa G-Tech. This wen damaged by unauthorized able to the purcrization numbe
uring the warra facility or to ing, packing aexcluding partpair, replaceme
returned Prodriginal shipping
mation on hower or to acquire3 Stanford Stre9 or support@g
A PRODUCT BETY PERIOD, THLL BE REPAIOVE. INCIDENCLUDING WITHG FROM BREAANTY ARE NOT
O THE EXTENTUDED BOTH FOT NOT UNCON
GE.
warrants your Pworkmanship, ranty period. within the warrepair or replacor Products wild will be ei
arts or Productswarranty shall ny accident, mis service or pachaser by obtaer (RMA) and anty period to G-Tech. The p
and insurance s and labor, ent or refundduct must beg container.
w to obtain ware shipping matet, Santa Moni
g-technology.co
ECOMES DEFECE PURCHASERIR OR REPLANTAL OR CONSHOUT LIMITATIACH OF ANY T THE RESPONST PERMITTED OR PROPERTY DSCIONABLE, FO
Page
roduct against under normal If the Product rranty period, ce the Product. ll be furnished ther new or s shall become not apply if the suse, abuse or arts. Warranty ining a Return by delivering an authorized urchaser shall costs and all necessary to
d under this e shipped to
rranty service, terials, contact ca, CA 90404,
om.
CTIVE DURING R’S EXCLUSIVE ACEMENT AS SEPROUENTAL ION LOSS OF EXPRESS OR
SIBILITY OF G-BY LAW, ARE DAMAGE, AND OR PERSONAL
e 20
G-SPE
APPE
1
2
3
4
5
6
EED eS INSTA
ENDIX A: WEB
1. Manage: Array: Thisweb GUI. Gfrom this paDevices: Hpage (you page as tperformancSpare Poodrives can bcalled hot sadded to th
2. Events: Allrecorded heThese evennotification
3. Tauvo
asks: Schtomaticallume.
4. Settings: settings snotification.
5. Driv e Stath rd drivesa
6. o L gout: Sa
ALLATION G
B GUI
s is the main G-SPEED eS is age. (See Appe
Hard drive paramshould not m
the drives aree with the G-SP
ol: When confbe assigned to spare). These de Array in the e
events of the ere, such as ants can be em under the “Set
edule the G-Teinly verify the t
Configure theuch as logi. See Appendix
tus: Check th including detai
ay goodbye
UIDE - Windo
screen of the configured anendix A.1 for demeters are mod
make any chane configured PEED eS. figured in prot a “spare pool”drives will be aevent of a drive
G-SPEED eS carray changes mailed by settinttings” tab.
ch controller totegrity of the R
e G-SPEED en password x A.4 for details
e status of ailed SMART dat
ows
G-SPEED eS nd monitored etails) dified on this nges on thi
for optims al
tected mode ” (sometimes automatically e failure.
controller are and failures. ng up email
o RAID
S controllerand email
s
ll connected ta.
A.1 M age: an A
1. Name: A
2. Type: Di
3. Capacity
4. Cache P
for RAIDappendix
5. OS Namdisplay in
6. Status: DNormaCriticaInitialRebui
Array
Array name (as
splays RAID lev
y: you guessed
Policy: DisplayD protected ax B.1.7.7
me: Controllern Disk Utility.
Displays currenal: All systemsal: Drive failurelizing: Buildingilding: Parity d
shown in GUI
vel of array.
it… capacity of
s current writearrays. For m
r assigned na
nt status of arra go e has occurred g RAID 1, 5 or ata being recon
Page
only).
f the array.
e cache policy more info see
ame that will
ay.
10 array nstructed
e 21
G-SPE
7.
EED eS INSTA
Maintenanceoptions for cuon RAID level
RAID 0
7 1. Delete: D
WARNTHE A
7.2 Unplugcontroller. Boption. This system witho
NOTE: recommdisconne
7.3 Rename
ALLATION G
e: Displays conurrent array. Thl of the array.
Deletes current
NING: THIS ARRAY AND AL
: This will disBe sure to cloenables the arut causing an a
While the contmend shutting the ecting G-SPEED eS
: Renames arra
UIDE - Windo
figuration and he options diffe
t Array
OPERATION LL DATA ON I
sconnect the Aose all files berays to be unpalarm.
troller is “hot psystem down whe
S from the controlle
ay as displayed
ows
maintenance er depending
WILL DELETT!!
Array from theforelugged f
using throm th
pluggable,” we n connecting or er.
in the GUI.
TE
he is
he
7.4 OCE/ORLOnline Cacapacity oG-SPEED eOnline RAthe RAID
7.5 Shows the
location an
“Devic
RAID 5
7.6 Verify: Ve 7.7 Change CRAID 5 arrays.
Write-bis cachebut datfailure. Write-talways reads mappropr
LM: pacity Expansio
of an existing areS units are ad
AID Level Migralevel of an exis
e devices currend status.
ce_Controller
erifies the integ
Cache Policy: .
back: (Defaulted. This will resta loss may o through: Dat passed directlymay still be comriate
on: It is possibrray when addidded to the systation: it is posssting array.
ently part of t
r#_Port#_Driv
grity of the RAID
This option is
t) Data written sult in higher poccur in case
a written to ty to the disks. mpleted from t
Page
le to expand thtional tem. sible to change
the Array, their
ve#”
D set.
or available f
to the array performance, of a power
the array is Subsequent the cache, if
e 22
he
r
G-SPE
8. C
C
EED eS INSTA
Create Array Click on “Create
ALLATION G
Array” and the
UIDE - Windo
e following will
ows
appear.
8
8
8
8
8
8
8
8
.1 Array Type
.2 Array Namthe MAIN pa
.3 Initializatiocreation pro
Foregroucreation pcomplete. Backgroufor the creimmediate
NOTunti
.4 Cache Polic
a RAID 5 ar
Write-backwill result inoccur in caseWrite-throupassed direcstill be comp
All:.5 Select
.6 Available Dfor array cserial numbcapacity.
ocation:
ilable
L .7 Ava D
newavai
.8 Cre
array.lable.
ate: Asarray creatio
e: select the RA
me: This is theage of the GUI.
on Method: Seocess.
und: All controlprocess and th
und: Minimal eation process e use.
TE: RAID protectiol initialization is co
cy: This optionrray.
: Data written tn higher perfore of a power faiugh: Data writctly to the diskleted from the
Simple method
Disks: Displaycreation, showiber, size of th
“Controller#
Disks: Enter t Default is
s expected, seon process.
AID level for new
name that wi
ets the priority
ller resources ahe array is not
controller reso and the array
n is not available mplete
n is available w
to the array is mance, but dailure. tten to the arraks. Subsequent cache, if appro
d to select all di
ys disks currening location, dhe disk and c
#/Port#/Drive
the desired caps the Maximu
electing this wi
Page
w array
ill be displayed
of the RAID
are used for tht available unt
ources are usey is available fo
hen creating
cached. This ata loss may
ay is always t reads may opriate
isks.
ntly available drive model, current free
e#”
pacity of the um capacity
ill begin the
e 23
d in
he til
ed or
G-SPE
9. Lo
co
Lo
10. Modis
11. Cacu
12. Madis
13. Rede
14. Be
EED eS INSTA
ocation: Showntroller.
ocation: “Contr
odel: Displayssks currently at
apacity: Displarrently attache
ax Free: Dispsks currently at
escan: Rescanevices attached
eeper Mute: M
NOTE: Beepedisconnected “Unplug” in th
ALLATION G
ws the location o
roller#/Port#/
s the drive mottached to the c
ays the advertied to the contro
lays the maximttached to the c
ns the eSATA .
Mutes audible be
er will sound when from the system w
he Array Maintenan
UIDE - Windo
of disks attache
/Drive#”
odel and serial controller.
sed capacity ooller.
mum free capacontroller.
bus to detect
eeper.
a drive fails or an awithout first selectinnce menu.
ows
ed to the
number of
of the disks
acity of the
t any new
array is ng
(This page left inte
entionally blan
Page
nk)
e 24
G-SPE
Ap
EED eS INSTA
pendix A.4: S
ALLATION G
ettings
UIDE - Windoows
1.
2.
3.
4. 5.
6.
7.
8. 9.
10
Auto Rebuildfeature. Whearray will autinserted. See
Audible Alar Rebuild Priotime dedicatewill rebuild thless responsiv SAF-TE: This
Listening PoG-SPEED webnetwork users
Password: C
SMTP Settinfor email nothere.
Recipients: A
Add Recipienotification. S
InformationWarning: WaError: Error e Test: Sends a
0. HDD Temperof the hard email. Defaucan operate u
d: Enables oren enabled, a tomatically rebe Section 12 for
rm: Enables or
ority: Sets theed to rebuildinghe array faster,ve to the system
s feature is not
ort: The port b GUI. Restri“ cs to access the
Changes login p
ng: Email sertification. Ente
A list of current
ent: Add emSelect Event lev
: Informationaarning events aevents are sent
a test email to
rature Threshdrive temperault is 50°C, houp to 60°C.
r disables the critical RAID 5
build when a nr details.
r disables the a
e amount of cog an array. Hi however the am.
currently suppo
used to conct to local acce GUI. Default i
password. Defau
rver informatioer your server
t email recipien
mail addressesvel to trigger a
l events are seare sent t
the new accoun
hold: Adjusts tture to triggeowever today’s
Page
auto-rebuild 5 or RAID 1 new drive is
udible alarm
ontroller CPU gher Priority array will be
orted.
to the nect ess” disables is Port 7402.
ult is 0000
on necessary information
nts.
s for email n email.
nt
nt
he threshold r a warning
s disk drives
e 25
G-SPEED eS INSTALLATION GUIDE - Windows
Page 26
APP plained
RAID Level Description Advantage Disadvantage Ideal For…
ENDIX B: RAID levels ex
0 Disk striping Offers the highest performance and a useable storage capacity of 100% of total available storage capacity
No fault tolerance - failure of one drive in the array results in complete data loss
Content creation applications requiring highest storage capacity
1 Mirroring Maximum level of data protection as identical data is written to multiple drives
Useable storage space is 50% of total available capacity
Applications in which data security is paramount
5 Disk striping with distributed parity
High read performance, medium write performance with data protection in case of a drive failure.
Useable storage capacity equals total capacity of all drives in the array less the capacity of one drive. For example, a 4x 1TB RAID 5 yields a useable capacity of 3 TB. Disk failure results in slight drop in performance
Content creation applications requiring data protection
10 Mirror of striped drive pairs
Higher performance than RAID 1 with same level of data protection.
Useable storage space is 50% of total available capacity
Content creation applications requiring data protection
JBOD Just-a-bunch-of-disks
Each drive can be accessed as an individual volume. Useable storage capacity is 100% of total available storage.
No fault tolerance Audio applications
Wm
U
w
APPENDIX C: Notes
hen the G-Tech web GUI is open dropped frames ay occur in editing applications such as Final Cut
ro and Premiere Pro. We recommend not having the GUI open while working in these progrP
ams. It is recommended not to exceed the standard eSATA cable length of 1 meter (3 feet).
p to (4) G-SPEED eS storage units can be attached o the G-Tech RAID controller for up to 16TB of
capacity and over 600 MB/sec of pt
erformance. eplacements / extra G-SPEED eS disk modules are R
available for purchase online at: ww.g-technology.com/products/g-speed-es.cfm
G-SPE
APPENDisk Ma
1
2.
EED eS INSTA
DIX D: Formaanagement
1. Open Disk MComputer> “Manage.
Select “Disk M
”
ALLATION G
atting G-SPEED
Management by from the Start
anagement”
UIDE - Windo
D eS using W
y right clicking t Menu and sele
ows
indows XP
on <My ectin
g
3.
4.
. The “Initializaccept all the
. When the W
eS listed as show the capbar as shown
e Wizard” will ae default values
Wizard completeDisk X (in this pacity and “Unn and select “N
appear. Click <s.
es you will see example Disk allocated.” Rigew Partition.”
Page
<Next> and
e the G-SPEED1). It will also
ght click on the
e 27
D o e
G-SPEED eS INSTALLATION GUIDE - Windows
Pag
gPa e 28
cepting the default values. When t r the values as shown. at” and then click <Next>.
7. he Wizard will complete and bring you back to t e Main isk Management screen. The G-SPEED eS will format in
ust a few seconds and be ready to use!
(This page left intentionally blank)
G-SPEED eS INSTALLATION GUIDE - Windows
5. The “New Partition Wizard” will open, click <Next>.
6. Follow the prompts, acyou reach this screen, ene ct “Perform a quick form
T hDj