fv-08vf2, fv-11vf2 whisperfit / whisperfit-lite€¦ · motor type ac ac ac ac type of motor...

2
WhisperFit / WhisperFit-Lite Ventilation Fans FV-08VF2, FV-11VF2 FV-05VFL4, FV-08VFL4, FV-11VFL4 FV-08VF2 FV-08VF2 FV-05VFL4 (with 3" duct adaptor) FV-05VFL4 (with 3" duct adaptor) n Low profile housing design fits in 2x6 construction n Ideal for remodeling projects and manufactured structured homes n NEW! WhisperFit-Lite models feature a flush mount grille and (2) 13W self-ballasted GU24 base CFL lamps n 4" duct with 3" duct adapter included n Can be used to comply with ASHRAE 62.2, LEED, IAP, California Title-24 and WA Ventilation Code FV-08VF2 (3" DUCT) FV-08VF2/FV-11VF2 FV-05VFL4/FV-08VFL4/FV-08VFL4 FV-08VF2 (4" DUCT) FV-11VF2 (3" DUCT) FV-11VF2 (4" DUCT) 4" duct 14-1/2" 5-5/8" 10-1/4" 10-1/4" 4" 3" 14-1/2" or 22-1/2" 13" 13" 13" 14-1/2" 10-1/4" 4" 5-5/8" 3" 14-1/2" or 22-1/2" 10-1/4" 13" 4" duct VF13370SS - October 2013 Design and specifications subject to change without notice. Panasonic Eco Solutions of North America Eco Products Division Two Riverfront Plaza Newark, NJ 07102 us.panasonic.com/ventfans For Order Information PHONE: 866-292-7299 FAX: 888-553-0723 [email protected] FV-05VFL4 (3" DUCT) 3" Duct FV-05VFL4 (4" DUCT) 4" Duct FV-08VFL4 (3" DUCT) 3" Duct FV-08VFL4 (4" DUCT) 4" Duct FV-11VFL4 (3" DUCT) 3" Duct FV-11VFL4 (4" DUCT) 4" Duct ADDITIONAL BENEFITS • Built-in metal flange provides blocking for penetrations through drywall as an Air Barrier, and assists with the decrease in leakage in the Building Envelope during blower door testing • UL listed for tub/shower enclosure when used with a GFCI protected circuit • Lighted models feature 75 Lumens Per Watt(LPW), the highest LPW in the industry, and also include a convenient night-light feature • 3-year warranty on parts, 1 year on CFL lamps

Upload: others

Post on 20-Oct-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

  • Whis

    perF

    it /

    Whis

    perF

    it-L

    ite

    Ven

    tilat

    ion

    Fans

    FV-08VF2, FV-11VF2

    FV-05VFL4, FV-08VFL4, FV-11VFL4

    FV-08VF2

    FV-08VF2

    FV-05VFL4 (with 3" duct adaptor)

    FV-05VFL4 (with 3" duct adaptor)

    n Low profile housing design fits in 2x6 construction

    n Ideal for remodeling projects and manufactured structured homes

    n NEW! WhisperFit-Lite models feature a flush mount grille and (2) 13W self-ballasted GU24 base CFL lamps

    n 4" duct with 3" duct adapter included

    n Can be used to comply with ASHRAE 62.2, LEED, IAP, California Title-24 and WA Ventilation Code

    FV-08VF2 (3" DUCT)FV-08VF2/FV-11VF2

    FV-05VFL4/FV-08VFL4/FV-08VFL4

    FV-08VF2 (4" DUCT)

    FV-11VF2 (3" DUCT) FV-11VF2 (4" DUCT)

    FV-05VFL4/FV-08VFL4/FV-11VFL4

    4" duct

    14-1/2"

    5-5/8"

    10-1/4" 10-1/4

    "

    4"

    3"14-1/2" or

    22-1/2"

    13" 13"

    FV-08VF2/FV-11VF2

    13"

    14-1/2"

    10-1/4"

    4"5-5/8"

    3"

    14-1/2" or 22-1/2"

    10-1/4"

    13"

    4" duct

    VF13370SS - October 2013Design and specifications subject to change without notice.

    Panasonic Eco Solutions of North AmericaEco Products DivisionTwo Riverfront PlazaNewark, NJ 07102

    us.panasonic.com/ventfans

    For Order Information PHONE: 866-292-7299 FAX: 888-553-0723

    [email protected]

    FV-05VFL4 (3" DUCT)

    3" Duct

    FV-05VFL4 (4" DUCT)

    4" Duct

    FV-08VFL4 (3" DUCT)

    3" Duct

    FV-08VFL4 (4" DUCT)

    4" Duct

    FV-11VFL4 (3" DUCT)

    3" Duct

    FV-11VFL4 (4" DUCT)

    4" Duct

    ADDITIONAL BENEFITS • Built-in metal flange provides blocking for penetrations through drywall as an Air Barrier, and assists with the decrease in leakage in the Building Envelope during blower door testing

    • UL listed for tub/shower enclosure when used with a GFCI protected circuit• Lighted models feature 75 Lumens Per Watt(LPW), the highest LPW in the

    industry, and also include a convenient night-light feature• 3-year warranty on parts, 1 year on CFL lamps

  • Quiet Operation at .25" Water Gauge Static Pressure (INSTALLED PERFORMANCE)Any manufacturer can achieve low sone levels at .1" w.g. - the amount of static pressure with 10 feet of duct and a wall cap. But today’s houses have longer and more complicated duct runs. Since .1" w.g. is an unrealistic amount of static pressure when installed, ASHRAE, ENERGY STAR®, and LEED for Homes, have set the industry standard for performance measurement at .25" w.g. Panasonic leads the way with incomparable sone levels at both .1" and .25" w.g.

    *As tested by an EPA recognized lab**Lamp contains mercury. Dispose of according to local, state and federal laws. NOTE: 0.25" w.g. = Installed Performance

    *As tested by an EPA recognized lab**Lamp contains mercury. Dispose of according to local, state and federal laws. NOTE: 0.25" w.g. = Installed Performance

    WhisperFit

    SPECIFICATIONS FV-08VF2 FV-11VF2

    Characteristics (HVI tested data

    for 0.1" S.P.)

    Static Pressure in inches w.g. 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25

    Air Volume (CFM) 80 60 70 53 110 94 90 78

    Noise (sones) 0.8 1.0 0.8 1.1 1.5 1.5 1.5 2.0

    Power Consumption (watts) 24.5 24.3 24.5 24.2 33.1 32.8 33.0 32.7

    Energy Efficiency (CFM/Watt) 3.3 2.5 2.9 2.2 3.4 2.9 2.9 2.5

    Speed (RPM) 757 956 845 1007 830 1000 1029 1128

    Current (amps) 0.20 0.20 0.20 0.20 0.27 0.28 0.27 0.28

    MAX. Current (amps) 0.20 0.20 0.28 0.28

    Power Rating (V/Hz) 120/60 120/60 120/60 120/60

    Specifications

    Motor Type AC AC AC AC

    Type of Motor Bearing Ball Ball Ball Ball

    Thermal Fuse Protection Yes Yes Yes Yes

    Blower Wheel Type Sirocco Sirocco Sirocco Sirocco

    ENERGY STAR Qualified Yes Yes Yes Yes

    Installation

    Duct Diameter (Inches) 4 3 4 3

    Mounting Opening (Inches sq.) 10-1/2 10-1/2 10-1/2 10-1/2

    Grille Size (Inches sq.) 13 13 13 13

    Light Specifications

    Lamp Watts N/A N/A N/A N/A

    Lumens (lm) N/A N/A N/A N/A

    Lumens Per Watt (LPW) N/A N/A N/A N/A

    Color Rendering Index N/A N/A N/A N/A

    Color Temperature (Kelvin) N/A N/A N/A N/A

    Rated Life (hours) N/A N/A N/A N/A

    Lamp Model # N/A N/A N/A N/A

    Type of Lamp Socket N/A N/A N/A N/A

    Night Light Specs Night Light Watts N/A N/A N/A N/A

    Shipping Gross Weight (lbs) 11 11 11.2 11.2

    Approved Code/Standard/Regulation

    UL tub/Shower Enclosure Yes Yes Yes Yes

    Washington VIAQ Code Yes Yes Yes Yes

    California Title 24 Compliant Yes Yes Yes Yes

    Mfg in ISO 9001 Certified Facility Yes Yes Yes Yes

    WhisperFit-Lite

    SPECIFICATIONS FV-05VFL4 FV-08VFL4 FV-11VFL4

    Characteristics (HVI tested data

    for 0.1" S.P.)

    Static Pressure in inches w.g. 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25

    Air Volume (CFM) 50 34 50 35 80 67 70 60 110 95 90 78

    Noise (sones) 80 >80 >80 >80 >80

    Color Temperature (Kelvin) 3500K 3500K 3500K 3500K 3500K 3500K

    Rated Life (hours) 10,000 10,000 10,000 10,000 10,000 10,000

    Lamp Model # MLS13GU35 MLS13GU35 MLS13GU35 MLS13GU35 MLS13GU35 MLS13GU35

    Type of Lamp Socket GU24 GU24 GU24 GU24 GU24 GU24

    Night Light Specs Night Light Watts 4W 4W 4W 4W 4W 4W

    Shipping Gross Weight (lbs) 12.6 12.6 13 13 13.2 13.2

    Approved Code/Standard/Regulation

    UL tub/Shower Enclosure Yes Yes Yes Yes Yes Yes

    Washington VIAQ Code Yes Yes Yes Yes Yes Yes

    California Title 24 Compliant Yes Yes Yes Yes Yes Yes

    Mfg in ISO 9001 Certified Facility Yes Yes Yes Yes Yes Yes

    NEW NEW

    WhisperFit, WhisperFit-Lite Ventilation Fans

    New Lighted Models! WhisperFit-Lite contemporary flush mount grille now incorporates (2) 13-Watt ENERGY STAR rated self-ballasted GU24 base CFL lamps and a 4 Watt night light. 3500 Kelvin/High CRI/997 Lumens per lamp*/75 Lumens Per Watt/10,000 hours rated average life/equivalent to (2) 75 Watt incandescent lamps.

    *(2) 13W self-ballasted GU24 base CFL lamps included

    The ideal remodeling solution, premium low profile design and ultra-quiet performance