Fundamentals, Techniques, Pitfalls, and Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Limitations of MDCT Interpretation and Measurement Measurement 3 3 rd rd Annual Imaging & Physiology Summit Annual Imaging & Physiology Summit November 20 November 20 - - 21, 2009 21, 2009 Seoul, Korea Seoul, Korea Wm. Guy Weigold, MD, FACC Wm. Guy Weigold, MD, FACC Cardiovascular Research Institute Cardiovascular Research Institute Washington Hospital Center Washington Hospital Center Washington, DC Washington, DC

Upload: others

Post on 04-Oct-2020

17 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

Fundamentals, Techniques, Pitfalls, and Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Limitations of MDCT Interpretation and

MeasurementMeasurement

33rdrd Annual Imaging & Physiology SummitAnnual Imaging & Physiology Summit

November 20November 20--21, 200921, 2009 Seoul, KoreaSeoul, Korea

Wm. Guy Weigold, MD, FACCWm. Guy Weigold, MD, FACCCardiovascular Research InstituteCardiovascular Research Institute

Washington Hospital CenterWashington Hospital CenterWashington, DCWashington, DC

Page 2: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

Traditional helical CT lacks sufficient Traditional helical CT lacks sufficient temporal resolution to image the hearttemporal resolution to image the heartTraditional recon algorithms Traditional recon algorithms averageaverage all of the all of the

acquired data (do not temporize the data)acquired data (do not temporize the data)

Page 3: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

ECG Gating Permits Visualization of the ECG Gating Permits Visualization of the Moving HeartMoving Heart

Selected Phase

RetrospectiveECG-Gated Reconstruction

001011010101011001101100001110101010101010010100101010101010101000101101010101100110110000111010101010101001010010101010101010101101001010101010101010101010101010101010101010101010001011010101010100101010101010101010101010101010101010101010101000101101010101001001010101010101010101110100110101010101010101011010010010110010100101010101010101010111010011010101010101010101101001001011001010101010101010101010101010111001011010101010101001101010110101010111101010101010101010101011100101101010101010100110101011010101011100001010101100110101010010101101010101010110010011101010101010101010101010110011010101001010110101010101011001001110101010101010101010101001011010101011001101100001110101010101010010100101010101010101100101101010101100110110000111010101010101001010010101010101010101010100101010101010101010101010101010101010101010101000101101010101010010101010101010101010101010101010101010101010100010110101010100100101010101010101010111010011010101010101010101101001001011001010010101010101010101011101001101010101010101010110100100101100101010101010101010101010101011100101101010101010100110101011010101011110101010101010101010101110010110101010101010011010101101010101110000101010110011010101001010110101010101011001001110101010101010101010101011001101010100101011010101010101100100111010101010101010101010

001011010101011001101100001110101010101010010100101010101010101010100101010101010101010101010101010101010101010101000101101010101010010101010101010101011101001101010101010101010110100100101100101010101010101010101010101110010110101010101010011010101101010101110010101011001101010100101011010101010101100100111010101010101010101010010110101010110011011000011101010101010100101001010101010101010101001010101010101010101010101010101010101010101010001011010101010100101010101010101010111010011010101010101010101101001001011001010101010101010101010101011100101101010101010100110101011010101011100101010110011010101001010110101010101011001001110101010101010101010

Page 4: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

Prospective Cardiac CT: XProspective Cardiac CT: X--Ray Tube Mostly OffRay Tube Mostly Off

ProspectiveECG-Triggered Acquisition

00101101010101100110110000111010101010101001010010101010101010100010110101010110011011000011101010101010100101001010101010101010110100101010101010101010101010101010101010101010101000101101010101010010101010101010101010101010101010101010101010100010110101010100100101010101010101010111010011010101010101010101101001001011001010010101010101010101011101001101010101010101010110100100101100101010001011010101011001101100001110101010101010010100101010101010101000101101010101100110110000111010101010101001010010101010101010101101001010101010101010101010101010101010101010101010001011010101010100101010101010101010101010101010101010101010101000101101010101001001010101010101010101110100110101010101010101011010010010110010100101010101010101010111010011010101010101010101101001001011001010100010110101010110011011000011101010101010100101001010101010101010001011010101011001101100001110101010101010010100101010101010101011010010101010101010101010101010101010101010101010100010110101010101001010101010101010101010101010101010101010101010001011010101010010010101010101010101011101001101010101010101010110100100101100101001010101010101010101110100110101010101010101011010010010110010101000101101010101100110110000111010101010101001010010101010101010100010110101010110011011000011101010101010100101001010101010101010110100101010101010101010101010101010101010101010101000101101010101010010101010101010101010101010101010101010101010100010110101010100100101010101010101010111010011010101010101010101101001001011001010010101010101010101011101001101010101010101010110100100101100101010

Page 5: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

Pitfalls & LimitationsPitfalls & Limitations

••LimitationsLimitations••NoiseNoise••Motion ArtifactsMotion Artifacts••Gating ArtifactsGating Artifacts••Beam HardeningBeam Hardening••Volume AveragingVolume Averaging

••PitfallsPitfalls••MIP pitfallMIP pitfall••cMPR pitfallscMPR pitfalls••VR pitfallsVR pitfalls

Page 6: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

LimitationsLimitations

NoiseNoise

Page 7: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

““Thin SliceThin Slice”” scanning is required for coronary CTAscanning is required for coronary CTA…………but increases image noisebut increases image noise

•• Standard CT slice thickness = 5 mmStandard CT slice thickness = 5 mm•• Cardiac CT slice thickness = 0.5Cardiac CT slice thickness = 0.5--0.75 mm0.75 mm•• Why?Why?

•• Thin collimation = Better resolution of small structures Thin collimation = Better resolution of small structures (coronary arteries)(coronary arteries)

Page 8: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

Axial Recons: Thin Slice = High ResolutionAxial Recons: Thin Slice = High Resolution

1x5.0mm image1x5.0mm image

8x0.67mm MIP8x0.67mm MIP

Page 9: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

Coronal & Oblique ReconsCoronal & Oblique ReconsThin slice CT = preservation of zThin slice CT = preservation of z--axis resolutionaxis resolution

1x5.0mm image1x5.0mm image

8x0.67mm MIP8x0.67mm MIP

Page 10: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

““Thin SliceThin Slice”” scanning is required for coronary CTAscanning is required for coronary CTA…………but increases image noisebut increases image noise

•• Case ExampleCase Example•• 37 yo woman37 yo woman•• History of hypertension, diabetesHistory of hypertension, diabetes•• Symptom: palpitations during exerciseSymptom: palpitations during exercise•• Treadmill stress test:Treadmill stress test:

•• Palpitations during exercise = PVCPalpitations during exercise = PVC’’ss•• But also: mild ischemia, anterior wall But also: mild ischemia, anterior wall artifact?artifact?

Page 11: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

CT ScanCT Scan

•• 55’’22”” (1.57 m) tall and 272 lbs (124 kg)(1.57 m) tall and 272 lbs (124 kg)•• BMI = BMI = 5050 kg/mkg/m22

•• Pulse 71 bpm (sinus rhythm)Pulse 71 bpm (sinus rhythm)•• 15 mg metoprolol i.v. 15 mg metoprolol i.v. 55 bpm55 bpm

•• Tube settings:Tube settings:•• 140 kVp, 425 mAs140 kVp, 425 mAs

•• 85 mL contrast @ 5 mL/sec85 mL contrast @ 5 mL/sec•• XX--ray dose: 553 mGy (9.4 mSv)ray dose: 553 mGy (9.4 mSv)

Page 12: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating
Page 13: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

Obesity Creates Excessive Image NoiseObesity Creates Excessive Image Noise

•• Signal Signal –– to to –– noise problemnoise problem•• Morbid obesity = Morbid obesity = Image NoiseImage Noise•• + Weak + Weak ““signalsignal”” = = SNRSNR•• Poor SNR = Decreased test accuracyPoor SNR = Decreased test accuracy

Page 14: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

ContrastContrast--toto--Noise RatioNoise Ratio

contrast

noise

Patient Detector

Page 15: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

NoiseNoise

With optimal HR reduction and use of Dose With optimal HR reduction and use of Dose Modulation, it is Modulation, it is possiblepossible to obtain adequate image to obtain adequate image quality by using higher tube currentquality by using higher tube current……

58yo F58yo F66’’ 250 lb BMI 36250 lb BMI 36

59yo F59yo F55’’33”’”’ 240 lb BMI 42240 lb BMI 42

Page 16: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

NoiseNoise

ButBut only at the cost of significantly higher radiation only at the cost of significantly higher radiation exposureexposure……

990 mGy990 mGy17 mSv17 mSv

1229 mGy1229 mGy21 mSv21 mSv

Page 17: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

The Obese PatientThe Obese Patient

Do Not Do Cardiac CTDo Not Do Cardiac CTDo Cardiac CTDo Cardiac CT

Weak indicationWeak indication

High heart rateHigh heart rate

Irregular rhythmIrregular rhythm

Elevated CrElevated Cr

CABG / StentCABG / Stent

Younger (<50)Younger (<50)

WomenWomen

BMI > 45BMI > 45

Cath undesirableCath undesirable

Pulse < 65 bpmPulse < 65 bpm

Regular rhythmRegular rhythm

Good IV accessGood IV access

Normal renal functionNormal renal function

Older (>70)Older (>70)

MenMen

BMI < 40BMI < 40

Page 18: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

MotionMotion

LimitationsLimitations

Page 19: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

Motion Artifact: ConceptsMotion Artifact: Concepts

•• Temporal resolution is like shutterspeedTemporal resolution is like shutterspeed•• It takes time to acquire the imageIt takes time to acquire the image

•• Time required = temporal resolutionTime required = temporal resolution•• In CCT the time is 80In CCT the time is 80--200 ms200 ms•• In cineangiography the time is 10 msIn cineangiography the time is 10 ms

•• Motion during acquisition creates artifacts which may be Motion during acquisition creates artifacts which may be misinterpreted as pathologymisinterpreted as pathology

•• To prevent distortion:To prevent distortion:•• (a) Breath(a) Breath--holdhold•• (b) Heart rate modulation(b) Heart rate modulation

Page 20: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

Respiratory MotionRespiratory Motion

Page 21: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

Respiratory motionRespiratory motion

Page 22: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

Respiratory motionRespiratory motion

•• CACS = 0CACS = 0•• Breathing during Breathing during

scanscan

Page 23: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

Respiratory motion: pseudostenosisRespiratory motion: pseudostenosis

Page 24: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

Respiratory MotionRespiratory Motion

•• Avoid at all costs!Avoid at all costs!•• Nurses & Techs should very carefully explain to Nurses & Techs should very carefully explain to

patientpatient•• ** Practice breath holding**** Practice breath holding**

Page 25: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

Cardiac Motion (phase specific)Cardiac Motion (phase specific)

Always Always review review

coronary CT coronary CT angiograms angiograms in multiple in multiple

phases phases (usually 3)(usually 3)

75%75% 70%70%(50ms earlier)(50ms earlier)

Page 26: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

75% phase 80% phase

Cardiac Motion (phase specific)Cardiac Motion (phase specific)

Page 27: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

NonNon--Coronary Motion ArtifactCoronary Motion Artifact

Page 28: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

Heart Rate Modulation for Cardiac CTHeart Rate Modulation for Cardiac CT

•• Heart rate & rhythm significantly influence CCT Heart rate & rhythm significantly influence CCT image quality *image quality *

•• High quality requires aggressive heart rate High quality requires aggressive heart rate modulationmodulation

•• Target heart rate << 65 bpmTarget heart rate << 65 bpm•• Nitroglycerin (800 ug)Nitroglycerin (800 ug)•• Review quality before discharging ptReview quality before discharging pt

*Hoffman MHK et al. Radiology 2005;234:86*Hoffman MHK et al. Radiology 2005;234:86--9797Noninvasive coronary angiography with 16Noninvasive coronary angiography with 16--detector row CT: Effect of heart ratedetector row CT: Effect of heart rate

Page 29: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

Gating ArtifactsGating Artifacts

LimitationsLimitations

Page 30: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

Gating Artifact ConceptsGating Artifact Concepts

•• Actually a form of motion artifactActually a form of motion artifact•• Entire cardiac CT is performed during one, single, brief Entire cardiac CT is performed during one, single, brief

acquisitionacquisition•• Images are reconstructed after the fact, using the ECG Images are reconstructed after the fact, using the ECG

timetime--stampstamp•• MotionMotion--free axial images are reconstructed from the data free axial images are reconstructed from the data

obtained during the endobtained during the end--diastolic portion of the cardiac cycle, as diastolic portion of the cardiac cycle, as defined by the ECGdefined by the ECG

•• Usually 75% of the length of the cardiac cycleUsually 75% of the length of the cardiac cycle

Page 31: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

GatingGating

Page 32: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

Example of Gating Artifact: PVCExample of Gating Artifact: PVC

Page 33: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

CCTA: Chest PainCCTA: Chest Pain

Page 34: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

CCTA Chest PainCCTA Chest Pain

Page 35: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

CCTA Chest PainCCTA Chest Pain

PVCPVC PVCPVC PVCPVC

Page 36: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

CCTA Chest PainCCTA Chest Pain

Page 37: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

Beam HardeningBeam Hardening

LimitationsLimitations

Page 38: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

Beam Hardening (Metal Lead)Beam Hardening (Metal Lead)

Page 39: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

Streak Artifact (also associated with metal)Streak Artifact (also associated with metal)

Page 40: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

Beam HardeningBeam Hardening

Page 41: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

Volume AveragingVolume Averaging((““blooming artifactblooming artifact””))

LimitationsLimitations

Page 42: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

Volume AveragingVolume Averaging

Page 43: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

PitfallsPitfalls

MIP PitfallMIP Pitfall

Page 44: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

MIP PitfallMIP Pitfall

5 mm MIP5 mm MIP 0.67 mm Image0.67 mm Image

Page 45: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

MIP PitfallMIP Pitfall

Page 46: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

PitfallsPitfalls

CMPR PitfallCMPR Pitfall(Curved Multi(Curved Multi--planar Reformation)planar Reformation)

Page 47: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

cMPR PitfallcMPR Pitfall

Page 48: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

cMPR Pitfall: pseudostenosiscMPR Pitfall: pseudostenosis

Page 49: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

PitfallsPitfalls

VR PitfallVR Pitfall(Volume Rendering)(Volume Rendering)

Page 50: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

VR PitfallVR Pitfall

Lesion Lesion ““severityseverity”” can be increased or decreased!can be increased or decreased!Volume rendered images are Volume rendered images are notnot reliable for evaluating stenosis severity.reliable for evaluating stenosis severity.

Page 51: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

Common Limitations and Pitfalls in Cardiac CTCommon Limitations and Pitfalls in Cardiac CT

Limitation or PitfallLimitation or Pitfall ResultResult ResolutionResolutionInadequate HRMInadequate HRM NonNon--dx studydx study ReRe--medicate & repeatmedicate & repeat

ArrhythmiaArrhythmia Incomplete studyIncomplete study Edit ECGEdit ECG

Morbidly obese patientMorbidly obese patient NonNon--dx studydx study Adjust parameters, or do Adjust parameters, or do not scannot scan

Heavy CalcificationHeavy Calcification Incomplete studyIncomplete study Do not scanDo not scan

Stairstep artifactStairstep artifact OvercallOvercall Recognize artifactRecognize artifact

MIP pitfallMIP pitfall UndercallUndercall Never use only axial images Never use only axial images for diagnosisfor diagnosis

MPR pitfallMPR pitfall OvercallOvercall Use multiple MPR Use multiple MPR projectionsprojections

3D Volume pitfall3D Volume pitfall Over or UndercallOver or Undercall Never use only 3D volume Never use only 3D volume for diagnosisfor diagnosis

Page 52: Fundamentals, Techniques, Pitfalls, and Limitations of ...Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement ... •Motion Artifacts •Gating

ConclusionsConclusions

Careful attention to patient Careful attention to patient preparation & image preparation & image acquisition will help avoid acquisition will help avoid artifactsartifacts

A systematic approach to case A systematic approach to case interpretation will help interpretation will help avoid pitfallsavoid pitfalls