fujitsu 2012 catalog

88
2012 PRODUCT CATALOGUE Distributed by : 3EF005-1201E Notice for specifications I.U.=Indoor Unit O.U.=Outdoor Unit Qu=Quiet * =Not decided yet •Specifications and design are subject to change without notice for future improvement. •For further details, please check with our authorised dealer. •Cooling/Heating capacities are based on the following conditions. Cooling Indoor temp. Outdoor temp. : 27˚C DB/19˚C WB : 35˚C DB/24˚C WB Heating : 20˚C DB/15˚C WB : 7˚C DB/6˚C WB Indoor temp. Outdoor temp. 1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www. fujitsu-general.com/ •Actual products’ colors may be different from the colors shown in this printed material. Copyright© 2008-2012 Fujitsu General Limited. All rights reserved. •“ ” and ” are worldwide trademarks of FUJITSU GENERAL LIMITED and are registered trademarks in Japan and other countries or areas. •“ ” is a worldwide trademark of FUJITSU GENERAL LIMITED •Other company and product names mentioned herein may be registered trademarks, trademarks or trade names of their respective owners. Fujitsu General (Thailand) Co., Ltd. ISO 9001 Certified number : 01 100 89394 ISO 14001 Certified number : 01 104 9245101 Fujitsu General (Shanghai) Co., Ltd. ISO 9001 Certified number : 01 100 79269 ISO 14001 Certified number : 272043 Fujitsu General Central Air-conditioner (Wuxi) Co., Ltd. ISO 9001 Certified number : 00608Q11061R2M ISO 14001 Certified number : 00609E20454R2M The Intelligent Choice in Comfort

Upload: daikaras

Post on 30-Mar-2016

317 views

Category:

Documents


21 download

DESCRIPTION

Fujitsu general air conditioners catalog 2012

TRANSCRIPT

Page 1: Fujitsu 2012 catalog

2012 PR

OD

UC

T C

AT

ALO

GU

E

Distributed by :

3EF005-1201E

Notice for specificationsI.U.=Indoor Unit O.U.=Outdoor Unit Qu=Quiet * =Not decided yet•Specifications and design are subject to change without notice for future improvement.•For further details, please check with our authorised dealer.•Cooling/Heating capacities are based on the following conditions.

Cooling Indoor temp.Outdoor temp.

: 27˚C DB/19˚C WB: 35˚C DB/24˚C WB Heating : 20˚C DB/15˚C WB

: 7˚C DB/6˚C WBIndoor temp.Outdoor temp.

1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japanhttp://www.fujitsu-general.com/

•Actual products’ colors may be different from the colors shown in this printed material.

Copyright© 2008-2012 Fujitsu General Limited. All rights reserved.

•“ ” and “ ” are worldwide trademarks of FUJITSU GENERAL LIMITED and are registered trademarks in Japan and other countries or areas.•“ ” is a worldwide trademark of FUJITSU GENERAL LIMITED•Other company and product names mentioned herein may be registered trademarks, trademarks or trade names of their respective owners.

Fujitsu General (Thailand) Co., Ltd.

ISO 9001Certified number : 01 100 89394

ISO 14001Certified number : 01 104 9245101

Fujitsu General (Shanghai) Co., Ltd.

ISO 9001Certified number : 01 100 79269

ISO 14001Certified number : 272043

Fujitsu General Central Air-conditioner (Wuxi) Co., Ltd.

ISO 9001Certified number : 00608Q11061R2M

ISO 14001Certified number : 00609E20454R2M

The Intelligent Choice in Comfort

Page 2: Fujitsu 2012 catalog

003003002

Fujitsu General creates high-quality and environmentally-friendly products that provide good comfort in accordance with our basic policy to a “create comfortable environment” by utilizing the air conditioning technology and creativity we have fostered over many years.

The Headquarters R&D Center is equipped with a wide range of testing equipment envisioning a variety of operating conditions. This includes a testing tower with a 60m height difference for buildings. We provide high quality & reliable products that meet the customers’ needs from all over the world through this advanced R&D center and 6 production companies based in China and Thailand.

• FUJITSU GENERAL AMERICA, INC.

• FUJITSU GENERAL DO BRASIL LTDA.

• FUJITSU GENERAL (ASIA) PTE. LTD.

• Sales Companies

• Head Office

• Manufacturing Companies

• FUJITSU GENERAL (THAILAND) CO., LTD. • FUJITSU GENERAL ENGINEERING (THAILAND) CO., LTD.• FGA (THAILAND) CO., LTD.

• FUJITSU GENERAL LIMITED

• FUJITSU GENERAL ORIENT INTERNATIONAL ELECTRONICS SALES (SHANGHAI) CO., LTD.

• FUJITSU GENERAL (SHANGHAI) CO., LTD.• F.G.L.S. ELECTRIC CO., LTD.

• FUJITSU GENERAL CENTRAL AIR-CONDITIONER (WUXI) CO., LTD.

• FUJITSU GENERAL (EURO) GmbH• FUJITSU GENERAL (U.K.) CO., LIMITED• FG EUROFRED LIMITED• WAVE AIR CONDITIONING LIMITED

• FUJITSU GENERAL (TAIWAN) CO., LTD.

• FUJITSU GENERAL NEW ZEALAND LIMITED

• FUJITSU GENERAL (AUST.) PTY LIMITED

• FUJITSU GENERAL (MIDDLE EAST) FZE

R&D CenterAnd 60 m Height Difference Testing Tower

FGA (Thailand) Co., Ltd.

Fujitsu General (Shanghai) Co., Ltd.

Fujitsu General Central Air-conditioner (Wuxi) Co., Ltd.

F.G.L.S. Electric Co., Ltd.

Fujitsu General (Thailand) Co., Ltd.Fujitsu General Engineering (Thailand) Co., Ltd.

Page 3: Fujitsu 2012 catalog

003005004

Small VRF series

Hi-spec Design model

Air to Water system

VRF combination type

*1. Announced 1991. In room air conditioner for the home (our company’s investigation)*2. Announced 1994. In room air conditioner for the home (our company’s investigation)*3. Announced 2002. In room air conditioner for the home (our company’s investigation)

Air conditioner with the world’s first automatic self-cleaning filter system

(Suppliers)

(Factories)(Home)

Material and part manufacturing

Product development and design

Product manufacturing

Use

Waste and recycle

Environmental Management

System

Powerdiffuser

Lambda heat exchanger

*1 *2 *3

TM

The Fujitsu General Group strives for business activities that achieve harmony between contributing to protecting the global environment and company activities while making environmental protection activities an important issue in company management. The Fujitsu General Group is working to improve its environmental friendliness by building an environmental management system (EMS); taking environmental protection measures throughout the product life cycle of materials procurement, product development and design, manufacturing, and recycling; and by taking the environment into consideration during business activities such as by saving energy and resources and reducing waste.

Page 4: Fujitsu 2012 catalog

007006

Sub-cooler Heat exchanger

Optimized Inverter Control

DC fan motor realizes high power, wide operation range, and high efficiency.

DC Fan MotorDC Twin Rotary Compressor

In case of cooling circuit

The high efficiency DC inverter type "2-cylinder rotary compressor" is used for large capacity of split system. It has achieved higher energy efficiency compared with equal class of compressors by optimizing the structure inside the compressor.

High performance sub-cool heat exchanger

High Efficiency Heat Exchanger

Heat exchange performance is substantially improved by thin and high-density heat exchanger and multi-path efficiency technology.

High density multi-path heat exchanger

DC Fan Motor

DC Fan Motor

Indoor unit Outdoor unit

All DC Inverter Technology

For RAC For VRF

Inverter Control Base

DC Compressor

Indoor unitOutdoor unit

I-PAM (IPM*+PAM)Inverter control

I-PAM inverter control is a technology which reduces loss by adjusting the current waveform to a better sine waveform. This promotes the effective use of the input power supply to attain high performance.

Compressor

Heat exchanger

Over 90% of actual operation time, air conditioners are operated at partial capacity instead of rated capacity.We focused on high seasonal efficiency by all DC inverter control and high efficiency technology.

Fujitsu General air conditioners bring quality air to people and provide true comfort, energy saving, and clean environment through our core technology

It becomes more powerful with the newly developed high efficient compressor motor control.

More compact than conventional models

Vector I-PAM

Ø5mm

20mm

Refrigerant

HighHigh

CO

PC

OP

(%)(%)Heating part loadHeating part load

2525 5050 7575 100100

Conventional inverter control

I-PAM inverter control

Multi-path (image)

Frequency operation range

Higher performance achieved by mounting of counter type bypass circuit. (Large multi type, VRF)

V-PAM inverter control reduces the effects of magnetic flux and increases the maximum speed and efficiency of the compressor by vector control technology. With this technology, further miniaturization, higher efficiency, and better performance are attained.

IPM*: Intelligent Power Module

V-PAM (Vector+I-PAM)Inverter control

Temp.In addition, the voltage is raised at the start of operation and fast comfort is attainable by more powerful operation.

SettingTemp.

Time

I-PAM Inverter

Conventional Inverter

Page 5: Fujitsu 2012 catalog

009008

(24/30)

(24/30)

Automatic filter cleaner

Normal set temp. range Limit set temp. rangeTime

30°C

10

(˚C)

15 16 17 18

33 32 31 30 29

(˚C)

Vertical airflow

Horizontal airflow

Air conditioning load factor

Capacity

Operating sound

Time

100%

58dB

0

0

Heat load

Quiet priority low noise mode

Economy operation

Normal operationSettingtemperature

*1

*1. Announced September 9, 2002. In room air conditioner for the home (Our company’s investigation)

Power diffuser

Lambda heat exchanger

Economical and comfortable air conditioning environment is realized by various energy saving technologies such as sensor technology, original automatic filter cleaning function, and economical set temperature control, etc.

Human sensor catches movements of people in a room, and operates with lower capacity when people leave the room, which can save electric expense. When people come back to the room, it returns to previous operating mode.

Energy Saving ControlAutomatic filter cleaning

This function allows an energy saving of more than 25% a year and maintains a smooth airflow by preventing the filters from being clogged with dust.

Quick ComfortPowerful operation Outdoor unit low noise operation

Continuous operation by maximum air flow and maximum compressor speed after a certain period of time allows the temperature to reach the setting temp. quickly.Economy operation

Limits the maximum operation current, and the power consumption is cut down and the maximum load is suppressed.

Room temperature set point limitation

The minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants.

10°C Heat operation

When you leave, minimum heating operation is performed to maintain the room temperature. (Maintain at 10°C)

Human sensor control

Precision wind direction control is realized and ventilation efficiency is also improved by 3 technologies. Our airflow control makes your environment more comfortable.

Comfort Airflow

High heating capacity is realized even at low outdoor temperature by mounting the large heat exchanger or large DC rotary compressor and developing the high performance inverter PCB

Powerful Heating

Users can choose low noise levels, depending on the installation environment. The operation time can be set using the timer.

Quiet Control

+2°C *Max. 30°CCooling / Dry

Heating

-4°C *Max. 16°C

Saving operation

Set temp.

Set temp.

Human sensor

SAVE ! AUTORESTART

Normal operation Normal operation

Human sensor's coverage

6m

90° 100°

6mLarge fan

High performance inverter PCB

Large heat exchanger

Large intake

Double-blow flap

10°C

20°C

“10°C HEAT” Button ON

Setting temp.

Normal mode

Time

Tem

pera

ture

Powerful operation mode

Hea

ting

capa

city

(kW

)

Ambient temperature (°C)

High

-7 High

Keeping rated capacity

Large DC rotary compressor

Indoor unit operation START

Judgment(Over 20 min.)

Fujitsu General realizes a comfortable environment at all times by developing original air flow control. In addition, we pursue the various control technologies to provide you with a pleasant air-conditioned life.

Page 6: Fujitsu 2012 catalog

011010

Clean Filter

Individual Friendly Control Central Management Control

Wireless remote controller

New slim wirelessremote controller System controllerTouch panel

controller

Organic coating fin used heat exchanger

Air conditioner filter features

Deodorant and anti-bacteria filter can resolve the constituent of bad smell by the pre-filter mixed with special ceramic powder which gives near infrared rays effect.

Deodorant & Anti-bacteria Filter

Pre-filter

H+

O-

OH-

O+

Badsmell

Badsmell

*1

We are producing control systems that provide greater convenience for both individual and centralized control with operability suitable for the application and such features as one-touch selection and a range of batch control operation methods.

Fujitsu General is using ergonomics to expand the use of user friendly designs such as easy-to-read large LCD displays, easy-to-operate buttons, and displays with easily recognizable colors and icons.

Clean FunctionAutomatic filter cleaning

Drives away the bacteria and refreshes the air.The dirt and dust are bacteria-eliminated by photocatalytic filterHigh density air filter surely catches the dust in the air. The collected dust is automatically removed, and the air is always cleaned in a clean state.

Long-life Ion Deodorization Filter Apple-catechin Filter

Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol extracted from apples.

Central & Individual ControlUser-friendly operationMultiple language support

Perfect comfort pursued by removal of dust and odors and bacteria, etc. in the air, intake of fresh air, and other clean air conditioning technologies which always take health into consideration.

Drives away the bacteria and refreshes the air.The dirt and dust are bacteria-eliminated by photocatalytic filterHigh density air filter surely catches the dust in the air. The collected dust is automatically removed, and the air is always cleaned in a clean state.

*1. Announced September 9, 2002. In room air conditioner for the home (Our company’s investigation)

Page 7: Fujitsu 2012 catalog

013012

Approach to the New Energy Efficiency Standard

*1. By 2020, CO2 emission -20%, Renewable energy share 20%, Primary energy use -20%*2. Under development (Dec.2011)*3. New energy labeling requirement (EU) 626/2011

*4. Enforcement on January 1, 2013 Air conditioners up to 12 kW

Our models are reaching the "Class A" ranking, the highest energy efficiency level that is now shown on energy labels in Europe.

New Energy Labeling Requirement (EU) 626 / 2011

Strengthened heating performance and efficiency, low noise level, etc.

• Performance notation based on multiple points calculations that better match the actual operation

• Energy labeling revision• Raising of the CLASS A level

Current Energy Label New Energy Label *4

AO-AS-

A

There are seven classifications of energy efficiency, from A to G. The most efficient level is "A" and the least efficient level is "G".

Current Energy labeling points New Energy labeling points

Operatingpower consumption

Seasonal efficiency

SEER SCOP

• Integrates part load capacity• Optimized for several rating temperatures

Rated efficiency

• Full capacity• One point temperature condition

EER COP

• Operating power consumption• Standby power consumption• Crank case heater• Thermo off

New criteria

Sound pressure level

Annual efficientoperation

Reduce total power consumption

Low noise products

Total power consumption

• Three climate zone for heating (Average zone : mandatory) (Warmer and colder zone are optional)• Seasonal efficiency • Sound power level

From residential to commercial useDevelopment of a series of new Class A products

FUJITSU GENERAL provides the products which will meet the EU action plan 20/20/20*1 and the implementing measures for air-conditioners of the ECO-Design Directive (ErP)*2

• FUJITSU GENERAL is focusing on the development of high seasonal efficiency products that are adapted to meet the new energy efficiency requirements*3 starting from January 2013 and reinforcement demands starting from 2014. Highest energy class products are already available today.

Sound power level

Page 8: Fujitsu 2012 catalog

015014

Auto louver grill (Option) Auto louver grille provides comfort and efficient heating with louver controlled ductable outlet.

High COP & Powerful Heating model 9 / 12

High COP model 7 / 9 / 12 / 14

Thin & Slim Design with High COP & Powerful Heating

Simple flat design matches to various interior and

energy saving operation is realized by Human Sensor*.

Our advanced technology makes your life comfortable.*LT series only

New Small VRF System for light commercial and home use

Slim Duct

• Height 198mm Slim design with drain pump• Flexible installation• Selectable with a wide range of static pressure• Dual concealed type56-57 page

12 / 14 18

Design model Slim Duct type

26-29 page

Small VRF system 4 / 5 / 6 HP

Large VRF system (Heat Recovery type)

• Wide lineup of indoor units and controllers to support a variety of properties.• High energy saving• Powerful heating & Low noise design• More design flexibility110-115 page

• High energy saving & More comfort• Space saving & High efficiency combination

ForLarge Homes

ForSmall Office

Compact Outdoor Unit

FeatureRelease

Page 9: Fujitsu 2012 catalog

017016

174 Feature Explanation

170 Deodoriser

162 Air to Water

160 Window

156 Energy Recovery Ventilator

152 Optional Parts for VRF

098 VRF

094 Optional Parts for Split & Multi Split

068 Multi Split

022 Split

Page 10: Fujitsu 2012 catalog

019018

Split

AOYG18LAC2

AOYG18LAT3

AOYG24LAT3

AOYG30LAT4

AOYG36LATT

AOYG45LATT

AOYG45LAT8

AOYG54LATT

AJYA90EATAAJYA90TATA

AOYG14LAC2

Multi Split

Ceiling Wall024 page

2.07

2.6 3.512

4.114

5.318

Capacity (kW)Model Code

10.636

8.830

7.124

13.245

15.854

17.660

26.4909

AWYZ14LB AWYZ18LB AWYZ24LB

026 page

Wall Mounted

030 page

WallMounted

072 pageUp to 2 Units

072 pageUp to 3 Units

072 pageUp to 4 Units

092 pageBig Multi

090 page

Simultaneous Multi Twin / Triple

038 pageFloor

040 page

Compact Cassette /Cassette

048 pageFloor/Ceiling Universal

052 pageCeiling

056 pageSlim Duct

058 page

Compact Duct /Medium Static Pressure Duct

064 page

High Static Pressure Duct

Constant

Constant

Constant

Constant

Constant

074 pageUp to 8 Units

Constant

Constant

Constant

ASYG12LUASYG09LU

ASYG09LT ASYG12LT

ASYG12LE ASYG14LE

ASYG14LU

ASYG09LEASYG07LE

ASYG07LU

ASY12UC

ASYG18LF

ASY18UB

AGYF09LA AGYF12LA AGYF14LA

AUYG12LVLB AUYG14LVLB AUYG18LVLB

AUY18UB

ABYF24LB

AUYF24LB

AUY25UU

ABY24UB

AUY30UU AUY36UU AUY45UU AUY54UU

AUYA30LB AUYA36LB/AUYG36LR AUYA45LC/AUYG45LR AUYA54LC/AUYG54LR

ABYA30LB ABYA36LB/ABYG36LR ABYA45LC/ABYG45LR ABYA54LC/ABYG54LR

ASYG24LF

ASY24UB

ASYG30LF

ASY30UBASY9UCASY7UB

ABYG18LVTB

ABY18UB

ARYF24LB

ABY30UB ABY36UB ABY45UB ABY54UB

ARY60UU ARY90TL

ARYA30LB ARYA36LB/ARYG36LM ARYA45LC/ARYG45LM

ARY18UU ARY25UU ARY30UU ARY36U(1)/ARY36UU ARY45UU

AJYA90EATBAJYA90TATB

Individual

Simultaneous

High COP &Powerfulheating

High COP

Standard

ARYG12LLTB ARYG14LLTB ARYG18LLTB

ARYC45LC/ARYG45LH ARYC54LC/ARYG54LH

3phase 3phase 3phase

3phase 3phase

3phase 3phase

3phase 3phase

3phase3phase3phase

3phase

Page 11: Fujitsu 2012 catalog

021020

AJYA90LALH

V R F

Deodoriser

DASY30S

172 page

Capacity (m3/h)Model Code

3.030

Window

AFY16UA

Capacity (kW)Model Code

4.616

Constant

160 page

22.48

28.010

33.512

40.014

45.016

50.418

55.920

61.522

67.024

Capacity (kW) 85.030

90.032

73.526

78.528

95.034

100.536

107.038

112.040

118.542

123.544

130.046

135.048

15.56

14.05

11.24HP

AJYA54LALHAJYA45LALHAJYA36LALH

AO90MPCMF

J-II series Heat Pump

110 page

S series Heat Recovery

100 page

Set Model AJYA72LALHAJYA72LALH

AJYA90LALH AJY108LALHAJY108LALH

AJY126LALH AJY144LALHAJY126LALH AJY144LALH

AJY144LALHHAJYA72LALH

AJYA72LALH

AJY162LALHAJYA90LALH

AJYA72LALH

AJY180LALHAJY108LALH

AJYA72LALH

AJY198LALHAJY108LALH

AJYA90LALH

AJY216LALHAJY108LALH

AJY108LALH

AJY234LALHAJY126LALH

AJY108LALH

AJY252LALHAJY144LALH

AJY108LALH

AJY270LALHAJY144LALH

AJY126LALH

AJY288LALHAJY144LALH

AJY144LALH

Unit 1Unit 2Unit 3

Set ModelUnit 1Unit 2Unit 3

V-II series Space savingHeat Pump

116 page

V-II series Energy efficiencyHeat Pump

116 page

AJY306LALHAJY108LALH

AJY108LALH

AJYA90LALH

AJY324LALHAJY108LALH

AJY108LALH

AJY108LALH

AJY342LALHAJY126LALH

AJY108LALH

AJY108LALH

AJY360LALHAJY144LALH

AJY108LALH

AJY108LALH

AJY378LALHAJY144LALH

AJY126LALH

AJY108LALH

AJY396LALHAJY144LALH

AJY144LALH

AJY108LALH

AJY414LALHAJY144LALH

AJY144LALH

AJY126LALH

AJY432LALHAJY144LALH

AJY144LALH

AJY144LALH

AJY198LALHHAJY126LALHH

AJYA72LALH

AJY216LALHHAJYA72LALH

AJYA72LALH

AJYA72LALH

AJY234LALHHAJYA90LALH

AJYA72LALH

AJYA72LALH

AJY252LALHHAJY108LALH

AJYA72LALH

AJYA72LALH

AJY270LALHHAJY126LALH

AJYA72LALH

AJYA72LALH

AJY288LALHHAJY108LALH

AJY108LALH

AJYA72LALH

AJY306LALHHAJY126LALH

AJY108LALH

AJYA72LALH

AJY324LALHHAJY126LALH

AJY126LALH

AJYA72LALH

AJY360LALHHAJY126LALH

AJY126LALH

AJY108LALH

AJY378LALHHAJY126LALH

AJY126LALH

AJY126LALH

AJY396LALHHAJY144LALH

AJY126LALH

AJY126LALH

11 13128

14 16155

WSYA128DA WSYA155DAAOYA45LBTL AOY54LJBYL

Air to Water6

65880

Capacity (kW) 550Model Code

Indoor UnitOutdoor Unit

High Powermodel

164 page

164 page

Indoor UnitOutdoor Unit

WSYA080DAWSYA065DAWSYA050DAAOYA24LALLAOYA18LALLAOYA18LALL

Comfortmodel

164 page

Compactmodel

165 page

Indoor UnitOutdoor Unit

WPYA080LA

WSYK160DA9WOYK112LAT

WSYK160DA9 WSYK160DA9WOYK140LAT

WSYG140DB6WOYG112LBT

WSYG140DB6WOYG140LBT

WOYK160LAT

10

WSYA095DAAOYA30LBTL

95

WPYA100LA

Single phase

Three phase

Page 12: Fujitsu 2012 catalog

022

An air conditioner that is people-friendly is also environment-friendly. Fujitsu General offers a broad lineup of products from large living rooms to bedrooms and children’s rooms. We make your room more comfortable with a wide range of air conditioner types from ceiling wall type with automatic filters and cleaning functions to wall mounted type that improve the air cleaning function. Of course these models feature highly efficient operation that conserves electricity.

Energy saving design to provide a comfortable indoor environment while being environment-friendly.

Ceiling Wall

Wall Mounted

Floor

Compact Cassette

Cassette

Floor/Ceiling Universal

Ceiling

Slim Duct

Compact Duct

Medium Static Pressure Duct

High Static Pressure Duct

024

026

038

040

044

048

052

056

058

060

064

Split type Air ConditionersThe Intelligent Choice in Comfort

Page 13: Fujitsu 2012 catalog

025024

Ceiling Wall

Rotor plates are installed above and below electromagnets.

"Vertical airflow" provides powerful floor level heating

"Horizontal airflow" does not blow cool air directly at the occupants in the room

Comfortable heating area

(Our company comparison)Approx.2.5 times*

*Compared to our conventional model ASY13PSCCW

Air is blown directly downwardPower diffuser (full open)

Big flap

Increased heat exchange efficiency

Specifications

9th year of record achievements. Automatic filter cleaning air conditioner

For AWYZ14 / 18LB For AWYZ24LB

Blown out horizontallyPower diffuser

Big flap

Increased heat exchange efficiency

Cooling range

(Our company comparison)Approx.1.7 times*

AWYZ14LB AWYZ18LB AWYZ24LB

CLASSA

ALLDC

CLASSA

ALLDC

CLASSA

ALLDC

Automatic filter cleaner

Clean & energy saving technologyDirt and dust are bacteria-eliminated by photocatalytic filter

Drives away bacteria and refreshes the air by UV (ultraviolet rays) illumination

Energy saving by automatic filter cleaning function

Axial gap fan motor enables nonconventional high power and high efficiency

CAE (Computer aided engineering) analysis

Antibacterial dust boxRemoves dirt and dust by double brushes. Dust collection is approx. twice that in the past. (our company comparison) Maintenance: Only throwing into a trash bin once every 2 years

Features (Compared to conventional models)Compact size with 1.5 more power output Self-driven method increases rotating efficiency by 10%. Our electromagnetic field simulation technology enables low vibration and low noise.

This function allows an energy saving of more than 25% a year and maintains a smooth airflow by preventing the filters from being clogged with dust.

New air trunk, which provides a smooth airflow, and axial gap fan motor increase the max. airflow by 10% over that of conventional models.

•Entire filter is cleaned automatically in approx. 2 minutes. •Since the filter is cleaned automatically, energy saving capability is displayed without regard to the load on the air conditioner.•Energy saving CLASS A cleared with a margin to spare.•2 exhaustive bacteria eliminating and deodorizing countermeasures keep the air in the room clean.

Axial gap method

Thin copper wire reducedelectric resistance.

Area, which confronts magnetic attraction is very wide and generates high power.

Rotor plate

Rotor plateElectromagnet

a b c d ea

b

c

d

e

*1

*1

*2

*3

Computer-designed fan provides a larger airflow than conventional models

*1. Announced September 9, 2002. In room air conditioner for the home (Our company's investigation) *2. Displays double the effect of a conventional optical medium and retains its property for a long time to suck in and remove approx. 99.99% of cigarette odors and bacteria, etc. *3. Announced December 13, 2004. As fan motor for air conditioner (Our company's investigation)

Dimensions Models: (Unit : mm)AWYZ14LB / AWYZ18LB / AWYZ24LB

POWERFULPOWERFULPOWERFUL

300

298899

250

170

40

Capacity

EER - Energy ClassCOP - Energy Class Running CurrentMoisture Removal

Airflow Rate (High)

Noise (Indoor)

Net Dimension H x W x D

Piping Connections (Small / Large)

Max Height Difference

Operation RangeCoolingHeating

Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)

Refrigerant

HeatingCooling/HeatingInput Power

Power SourceCooling

Cooling

Indoor / Outdoor

Cooling H/M/L/Q/SQCoolingNoise (Outdoor)

HeatingCooling/Heating

Indoor

Outdoor

°CDB

mm

m

kg(lbs)mm

kW

kg(lbs)

A

W/W

m3/h

I/h

dB(A)

mm

V/ Ø/Hz

kW

AWYZ14LB

AOYZ14LB

230/1/504.20(0.9~5.3)6.00(0.9~9.1)

1.02/1.354.12-A4.44-A4.5/5.9

2.146/43/35/29/24

46850/1910

250×899×29813.5(30)

578x790x30039(86)

6.35/12.7013.8/15.8 to 16.7 13.8/15.8 to 16.7 13.8/15.8 to 16.7

20(15)15

-10~43-15~24R410A

Model No.Indoor unit

Outdoor unit

AWYZ18LB

AOYZ18LB

230/1/505.20(0.9~5.9)6.70(0.9~9.7)

1.58/1.633.29-A4.11-A6.9/7.2

2.846/43/35/29/24

47850/1910

250x899x29813.5(30)

578×790×30039(86)

6.35/12.70

20(15)15

-10~43-15~24R410A

AWYZ24LB

AOYZ24LB

230/1/507.10(0.9~8.0)8.50(0.9~11.0)

2.21/2.243.21-A3.62-A

9.7/10.33.0

47/43/40/36/3253

880/3600250x899x298

14(31)830×900×330

62(137)6.35/15.88

30(15)20

-10~43-15~24R410A

Page 14: Fujitsu 2012 catalog

027026

Wall Mounted

Thin & Slim design

Specifications

Thin & Slim Design with High COP & Powerful Heating

ASYG09LT ASYG12LT

Dimensions Models: (Unit : mm)ASYG09LT / ASYG12LT

Capacity

EER - Energy ClassCOP - Energy Class Running CurrentMoisture Removal

Airflow Rate (High)

Noise (Indoor)

Net Dimension H x W x D

Piping Connections (Small / Large)

Max Height Difference

Operation RangeCoolingHeating

Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)

Refrigerant

HeatingCooling/HeatingInput Power

Power SourceCooling

Cooling

Indoor / Outdoor

Cooling H/M/L/QCoolingNoise (Outdoor)

HeatingCooling/Heating

Indoor

Outdoor

°CDB

mm

m

kg(lbs)mm

kW

kg(lbs)

A

W/W

m3/h

I/h

dB(A)

mm

V/ Ø/Hz

kW

ASYG09LT

AOYG09LT

230/1/502.5(0.9-3.5)3.2(0.9-5.4)0.505/0.660

4.95-A4.85-A2.6/3.3

1.342/36/32/21

50800/1,700

282×870×1859.5(21)

540×790×29033(73)

6.35/9.5213.8/15.8 to 16.7

20(15)15

-10~43-20~24R410A

Model No.Indoor unit

Outdoor unit

ASYG12LT

AOYG12LT

230/1/503.5(1.1-4.0)4.0(0.9-6.5)0.850/0.910

4.12-A4.40-A4.0/4.3

1.843/37/32/21

48850/2,050

282×870×1859.5(21)

620×790×29040(88)

6.35/9.5213.8/15.8 to 16.7

20(15)15

-10~43-20~24R410A

Thin and slim design is realized by high density multi-path heat exchanger and high efficiency wind blower.

Powerful heatingRated heating capacity is maintained up to an outdoor temperature lower than –7 °C. This new model can operate even at –20 °C low outdoor temperature.

Powerful operation mode20 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly.

Low noise mode for outdoor unitLow noise mode of outdoor unit can be selected by wireless remote controller.

Human sensor catches movements of people in a room, and operates with lower capacity when people leave the room. When people come back to the room, it automatically returns to previous operating mode.

Ø5mm

20mm -25 1050-5-10-15-20

1.0

2.0

3.0

4.0 New model

Current model

-25 1050-5-7-7 -10-15-20

1.0

2.0

3.0

4.0 New model

Current model

2.5kW class 3.5kW class

Hea

ting

Cap

acity

(kW

)

Hea

ting

Cap

acity

(kW

)

Outdoor Temperature (°C) Outdoor Temperature (°C)

Energy saving control

Weekly timer can be easily set by wireless remote controller.ON, OFF can be set up to 4 times in 1 day and up to 28 times in 1 week.For other modes, program timer and sleep timer can be also selected by one push.

3 Mode timer(Weekly/Program/Sleep)

Optional partsWired Remote Controller:Simple Remote Controller:Communication Kit:External Connect Kit:

UTY-RNNYMUTY-RSNYMUTY-TWBXFUTY-XWZXZ5

Wireless R.C. For ASYG09LT For ASYG12LT

Energy saving operation by detecting someone’s movement

282

870 185

337

55

Openpanel

Distributor 4-path

Refrigerant

Humansensor

Low ambient operation5040302010

0-10

-20°C

Cooling

24°C43°C

-10°C

Noise

Ratednoise level

100

or m

ore

Low noisePOWERFULPOWERFULPOWERFUL

Large intake 10°C

20°C

“10°C HEAT”Button ON

Indoor unitoperation START

Caution•When the room temperature is higher than 10°C, “10°C HEAT” operation does not start. Operation starts and maintains the room temperature at 10°C when the temperature drops below 10°C.

•When “10°C HEAT” operation stops, the room set temperature quickly returns to the preset temperature.

10°C HEAT Operation

The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied

*Only available with Wireless RC.

Heating

Slimness 185 mm

3dBDown

Low noisemode

Large fan

CLASSA

ALLDC

CLASSA

ALLDC

Human sensor catches movements of people in a room, and operates with lower capacitywhen people leave the room. When people come back to the room, it automatically returns toprevious operating mode.

Energy saving control

33333333 MMMMoMoMoMoModdddedededede ttttttt tiiimimimimimerererer

Energy saving operation by detecting someone’s movement

Humanansensorr

101010°C°C°C HH HEAEAEATTT OOOpOpperere tattatatatiiioioioionnnn *OnlOnly avy availaailableble withwith WirWireleseless RCs RC

Page 15: Fujitsu 2012 catalog

029028

Wall Mounted

Thin & Slim design

Specifications

ASYG07LU ASYG09LU ASYG12LU ASYG14LU

Dimensions Models: (Unit : mm)ASYG07LU / ASYG09LU / ASYG12LU / ASYG14LU

Capacity

EER - Energy ClassCOP - Energy Class Running CurrentMoisture Removal

Airflow Rate (High)

Noise (Indoor)

Net Dimension H x W x D

Piping Connections (Small / Large)

Max Height Difference

Operation RangeCoolingHeating

Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)

Refrigerant

HeatingCooling/HeatingInput Power

Power SourceCooling

Cooling

Indoor / Outdoor

Cooling H/M/L/QCoolingNoise (Outdoor)

HeatingCooling/Heating

Indoor

Outdoor

°CDB

mm

m

kg(lbs)mm

kW

kg(lbs)

A

W/W

m3/h

I/h

dB(A)

mm

V/ Ø/Hz

kW

ASYG07LU

AOYG07LU

230/1/502.0(0.5~3.0)3.0(0.5~4.0)0.460/0.660

4.35-A4.55-A2.6/3.4

1.038/35/31/21

46680/1,720

282×870×1859.5(21)

540×660×29023(51)

6.35/9.5213.8/15.8 to 16.7

20(15)15

-10~43-15~24R410A

Model No.Indoor unit

Outdoor unit

ASYG09LU

AOYG09LU

230/1/502.5(0.5~3.2)3.2(0.5~4.2)0.555/0.680

4.50-A4.71-A3.1/3.4

1.342/36/32/21

48800/1,720

282x870x1859.5(21)

540x660x29025(55)

6.35/9.5213.8/15.8 to 16.7

20(15)15

-10~43-15~24R410A

ASYG12LU

AOYG12LU

230/1/503.5(0.9~4.0)4.0(0.9~5.6)0.905/0.930

3.87-A4.30-A4.6/4.7

1.843/37/32/21

50850/1,940

282x870x1859.5(21)

540x790x29033(73)

6.35/9.5213.8/15.8 to 16.7

20(15)15

-10~43-15~24R410A

ASYG14LU

AOYG14LU

230/1/504.2(0.9~5.0)5.4(0.9~6.0)1.235/1.380

3.40-A3.91-A5.8/6.3

2.145/40/33/25

50900/1,940

282x870x1859.5(21)

540x790x29034(75)

6.35/12.713.8/15.8 to 16.7

20(15)15

-10~43-15~24R410A

Thin and slim design is realized by Ø5mm heat exchanger and high efficiency wind blower. Big open panel and High density multi path heat exchanger

Ø5mm

20mm

Weekly timer can be easily set by wireless remote controller.ON, OFF can be set up to 4 times in 1 day and up to 28 times in 1 week.For other modes, program timer and sleep timer can be also selected by one push.

Indicates the filter cleaning period by lamp.

3 Mode timer(Weekly/Program/Sleep)

Filter sign display

Optional partsWired Remote Controller:Simple Remote Controller:Communication Kit:External Connect Kit:

UTY-RNNYMUTY-RSNYMUTY-TWBXFUTY-XWZXZ5

Wireless R.C. For ASYG07/09LU For ASYG12/14LU

H282 X W870 X D185

10°C

20°C

“10°C HEAT”Button ON

Indoor unitoperation START

Caution•When the room temperature is higher than 10°C, “10°C HEAT” operation does not start. Operation starts and maintains the room temperature at 10°C when the temperature drops below 10°C.

•When “10°C HEAT” operation stops, the room set temperature quickly returns to the preset temperature.

10°C HEAT OperationThe room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied

*Only available with Wireless RC.

Large fan

Open panel

Low ambient operation

5040302010

0-10

-15°C

Cooling

24°CHeating

43°C

-10°C

282

870 185

337

55

100

or m

ore

Distributor 4-path

RefrigerantLarge intake

Low noisePOWERFULPOWERFULPOWERFUL

Powerful operation20 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly.

Low noise mode for outdoor unitLow noise mode of outdoor unit can be selected by wireless remote controller.

Noise

Ratednoise level

3dBDown

Low noisemode

185mm

Powerful

Setting temp.

Normal mode

Time

Tem

pera

ture

CLASSA

ALLDC

CLASSA

ALLDC

CLASSA

ALLDC

CLASSA

ALLDC

Page 16: Fujitsu 2012 catalog

031030

Wall Mounted

Compact design

Specifications Dimensions Models: (Unit : mm)ASYG07LE / ASYG09LE / ASYG12LE / ASYG14LE

High density heat exchanger arrangement

ASYG14LE

CLASSA

ALLDC

Wireless R.C.

Powerful operation

Indicates the filter cleaning period by lamp.

Filter sign display

Quiet operation

ASYG07LE ASYG09LE ASYG12LE

CLASSA

ALLDC

CLASSA

ALLDC

CLASSA

ALLDC

Simple design with energy saving.

For ASYG07/09/12LE

For ASYG14LE

Volume reduction of heat

exchanger: 30%

Making the tube thin:

7mm 5mm

Even temperature

Improved the heatexchanger effectiveness

660

For AOYG07/09/12LEFor ASYG07/09/12LE

Indoor unit Outdoor unit

Cooling mode (07/09/12 TYPE)

QuietFan speed

21dB(A)

Noise level

10°C

20°C

“10°C HEAT”Button ON

Indoor unitoperation START

20 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly.

Easy maintenance

Removable & washable panel

Caution•When the room temperature is higher than 10°C, “10°C HEAT” operation does not start. Operation starts and maintains the room temperature at 10°C when the temperature drops below 10°C.

•When “10°C HEAT” operation stops, the room set temperature quickly returns to the preset temperature.

Low noise mode for outdoor unitLow noise mode of outdoor unit can be selected by wireless remote controller.

Noise

Ratednoise level

3dBDown

Low noisemode

10°C HEAT Operation

The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied

Capacity

EER - Energy ClassCOP - Energy Class Running CurrentMoisture Removal

Airflow Rate (High)

Noise (Indoor)

Net Dimension H x W x D

Piping Connections (Small / Large)

Max Height Difference

Operation RangeCoolingHeating

Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)

Refrigerant

HeatingCooling/HeatingInput Power

Power SourceCooling

Cooling

Indoor / Outdoor

Cooling H/M/L/QCoolingNoise (Outdoor)

HeatingCooling/Heating

Indoor

Outdoor

°CDB

mm

m

kg(lbs)mm

kW

kg(lbs)

A

W/W

m3/h

I/h

dB(A)

mm

V/ Ø/Hz

kW

ASYG07LE

AOYG07LE

230/1/500.5-3.00.5-4.0

0.47/0.6854.47-A4.38-A2.7/3.5

1.043/38/31/21

45690/1720

260X790X1987.5(17)

540X660X29023(51)

6.35/9.5213.8/15.8 to 16.7

20(15)15

-10~43-15~24R410A

ASYG09LE

AOYG09LE

230/1/500.5-3.20.5-4.2

0.64/0.753.91-A4.27-A3.5/3.8

1.343/38/31/21

45690/1720

260X790X1987.5(17)

540X660X29023(51)

6.35/9.5213.8/15.8 to 16.7

20(15)15

-10~43-15~24R410A

Model No.Indoor unit

Outdoor unit

ASYG12LE

AOYG12LE

230/1/500.9-3.90.9-5.3

0.92/0.993.70-A4.04-A4.4/4.7

1.843/38/31/21

50690/1830

260X790X1987.5(17)

540X660X29029(64)

6.35/9.5213.8/15.8 to 16.7

20(15)15

-10~43-15~24R410A

ASYG14LE

AOYG14LE

230/1/500.9-5.00.9-6.4

1.105/1.3053.62-A3.83-A5.3/6.0

2.144/40/33/25

49770/1,800

280X790X2038.0(18)

540X790X29034(75)

6.35/12.713.8/15.8 to 16.7

20(15)15

-10~43-15~24R410A

Low ambient operation50

40

30

20

10

0

-10

43°C

-15°C

Cooling

24°CHeating

-10°C

Optional partsWired Remote Controller:Simple Remote Controller:Communication Kit:

External Connect Kit:

UTY-RNNYMUTY-RSNYMUTY-XCBXE (07/09/12 Type)

UTY-XCBXZ1 (14 Type)

UTY-XWZX

*Only available with Wireless RC.

ASYG07/09/12LE ASYG14LE

Low noisePOWERFULPOWERFULPOWERFUL

260

198

Powerful

Setting temp.

Normal mode

Time

Tem

pera

ture

198790

260

203790

280

Page 17: Fujitsu 2012 catalog

033032

Wall Mounted

Power Source

Capacity

Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)

Piping Connections (Small / Large)Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Height Difference

Refrigerant

Net Dimension H x W x D

OperationRange

CoolingHeating

Cooling/HeatingCoolingHeating

Cooling/Heating

CoolingHeating

CoolingIndoor/Outdoor

Indoor

Outdoor

Cooling H/M/L/Q

m

°CDB

kg(lbs)mm

kg(lbs)mmmm

mm

dB(A)

kW

kW

W/W

AI/h

m3/h

V/Ø/Hz

ASYG18LF

AOYG18LF

230/1/505.20(0.9~6.0)6.30(0.9~9.1)

1.52/1.713.42-A3.68-A6.8/7.6

2.843/37/33/26

51900/2070

320X998X23814(30.8)

620X790X29840(88)

6.35/12.812/1625(15)

20-10~46-15~24R410A

ASYG24LF

AOYG24LF

230/1/507.10(0.9~8.0)

8.00(0.9~10.6)2.20/2.21

3.23-A3.61-A9.7/9.8

2.747/42/37/32

521100/2340

320X998X23814(30.8)

578X790X31543(95)

6.35/15.8812/1630(15)

20-10~46-15~24R410A

ASYG30LF

AOYG30LF

230/1/508.00(2.9~9.0)8.80(2.2~11.0)

2.49/2.443.21-A3.61-A

10.9/10.73.2

48/42/37/3353

1100/3600320X998X238

14(30.8)830X900X330

61(135)9.52/15.88

12/1650(20)

30-10~46-15~24R410A

Indoor unit

Outdoor unitModel No.

Specifications

Simple & Elegant Appearance Design

ASYG18LF ASYG24LF ASYG30LF

CLASSA

ALLDC

CLASSA

ALLDC

CLASSA

ALLDC

Dimensions Models: (Unit : mm)ASYG18LF / ASYG24LF / ASYG30LF

(18/30)(24)

For ASYG24LFFor ASYG18LF For ASYG30LF

Wireless R.C.

“Vertical airflow” provides powerful floor level heating

Power diffuser

Power diffuser (full open)

46o

(˚C)

15 16 17 18

Outside air conditions: 35˚C 40% Operation contents: Cooling, Set temperature (Min set temp) 18˚C, airflow Hi, Air direction downward and front

(24/30)

Outside air conditions: 2˚C 60% Operation contents: Heating, Set temperature (Max set temp) 30˚C, airflow Hi, Air direction downward and front

33 32 31 30 29

(˚C)

(24/30)

Ion Deodorization Filter

Apple-catechin Filter

Pre Filter

Organic coating fin used heat exchanger

Antibacterial deodorizing pre-filter with special ceramic powder

Air conditioner filter features

Long-life* Ion Deodorization Filter

Apple-catechin Filter

Using different filters at both sides

The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.

Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol extracted from apples.

(*The filter can be used for approx. 3 years if it is washed under water to restore its surface action when it is dirty.)

Low ambient operation

Optional parts

Wired Remote Controller: UTY-RNNYMSimple Remote Controller: UTY-RSNYMExternal Connect Kit: UTY-XWZX

Flexible Installation

20m

25m18 type

30m

50m30 type

20m

30m24 type

Max. Height

Max. Piping Length

Easy maintenance

Simplification of drain pan cleaning improves maintenance-ability.

50

40

30

20

10

0

-10

46°C

-15°C

Cooling

24°CHeating

-10°C

“Horizontal airflow” does not blow cool air directly at the occupants in the room

998

238

320

520

520

590

721

25

ø 32

ø 16

ø 12

Refrigerant pipe flare connection (Liquid)Refrigerant pipe flare connection (Gas)Drain hose connection (Drain hose)

21

3

Page 18: Fujitsu 2012 catalog

035034

Wall Mounted

Handy type remote controller

Specifications Dimensions Models: (Unit : mm)ASY7UB / ASY9UC / ASY12UC

ASY7UB ASY9UC ASY12UC

For ASY7UB/9UC For ASY12UC

Easy maintenance

Easy maintenance has been realized as the front panel can be removed for easy access.

Symmetrical design

Compact design

Symmetrical, clean design that suits all interiors.

Auto swing louver

6-step air directions by auto swing louver.

Steps

Swing

Remote Control Unit Display(LCD)

Signal Transmitter

Fan Control Button

Vertical Set Button

Vertical Swing ButtonAcl Button

Set Temp. Button

Master Control Button

Coil Dry Button*

Test Run Button

*This function is only for ASY9UC/12UCTimer Button

Sleep Button

Start/Stop Button

-step6

187808

257

Capacity

EER - Energy ClassCOP - Energy Class Running CurrentMoisture Removal

Airflow Rate (High)

Noise (Indoor)

Net Dimension H x W x D

Piping Connections (Small / Large)

Max Height Difference

Operation RangeCoolingHeating

Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)

Refrigerant

HeatingCooling/HeatingInput Power

Power SourceCooling

Cooling

Indoor / Outdoor

Cooling H/M/L/QCoolingNoise (Outdoor)

HeatingCooling/Heating

Indoor

Outdoor

°C

mm

m

kg(lbs)mm

kW

kg(lbs)

A

W/W

m3/h

I/h

dB(A)

mm

V/ Ø/Hz

kW

ASY7UB

AOY7UB

230/1/502.202.30

0.83/0.752.65-D3.07-D3.9/3.6

1.038/35/33/29

43380/1350

257x808x1878(18)

535x650x25026(57)

6.35/9.5212.0/16.2 to 17.0

10(7.5)5

21~43-15~24R410A

ASY9UC

AOY9UC

230/1/502.602.95

1.07/0.902.43-E3.28-C4.8/4.1

1.340/38/35/30

46540/1350

257x808x1878(18)

535x650x25028(62)

6.35/9.5212.0/16.2 to 17.0

15(7.5)8

21~43-15~24R410A

ASY12UC

AOY12UC

230/1/503.253.95

1.35/1.282.41-E3.09-D5.9/5.6

1.840/38/36/33

48540/1700

257x808x1878(18)

535x695x25031(68)

6.35/9.5212.0/16.2 to 17.0

15(7.5)8

21~43-15~24R410A

Model No.Indoor unit

Outdoor unit

25.7cm

80.8cm

18.7cm

Page 19: Fujitsu 2012 catalog

037036

Wall Mounted

Specifications

ASY18UB ASY24UB ASY30UB

Dimensions Models: (Unit : mm)ASY18UB / ASY24UB / ASY30UB

Power Source

Capacity

Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)

Piping Connections (Small / Large)Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Height Difference

Refrigerant

Net Dimension H x W x D

OperationRange

CoolingHeating

Cooling/HeatingCoolingHeating

Cooling/Heating

CoolingHeating

CoolingIndoor/Outdoor

Indoor

Outdoor

Cooling H/M/L

m

°CDB

kg(lbs)mm

kg(lbs)mmmm

mm

dB(A)

kW

kW

W/W

AI/h

m3/h

V/Ø/Hz

ASY18UB

AOY18UB

230/1/505.40 5.70

1.85/1.852.92-C3.08-D8.3/8.3

2.0 41/37.5/34

52800/3200

320x1120x220

16(35)650x830x320

52(114)6.35/15.88

12.0/16.2 to 17.020(7.5)

80~43-6~24R410A

ASY24UB

AOY24UB

230/1/506.807.40

2.40/2.402.83-C3.08-D

10.6/10.52.5

45/42/3853

970/3200

320x1120x220

16(35)650x830x320

59(130)9.52/15.88

12.0/16.2 to 17.020(7.5)

80~43-6~24R410A

ASY30UB

AOY30UB

230/1/507.908.40

2.75/2.752.87-C3.05-D

13.0/13.03.0

47.5/44/40.554

1040/3320

320x1120x220

16(35)900X900X350

74(163)9.52/15.88

12.0/16.2 to 17.025(7.5)

150~43-6~24R410A

Indoor unit

Outdoor unitModel No.

For ASY18/24UB For ASY30UB

Powerful output in spite of small size

Though the indoor unit is compact, it features a large, high pressure cross fan (107mm diameter) in a center mounted configuration and a lambda type heat exchanger to provide plenty of power. The extra long diffuser provides a wide outflow opening for air. This ensures a large air outflow volume over a wide area to cool or heat all areas of the room.

Low noise

Multi airflow

Large independently driven power diffuser used

Expanded work space at bottom of casing increases piping space by 15%.

Increases piping space by 15%

•High efficiency fan construction ø7mm Lambda type evaporator improves the airflow path•Large independently driven power diffuser

ø7 lambda type evaporator

Large independently driven power diffuser

Others

Cooling Heating

Steps

SwingSteps

Swing43

2

1

432

1

Horizontal concentration and other air direction control

Wide down flow

•Double auto swing •2-way draining route

Power diffuser

Power diffuser

Easy installation

Low noise

34dB

(ASY18)

Large independently driven power diffuser

Refrigerant piping flare connection (Gas)Refrigerant piping flare connection (Liquid)Drain piping connection

21

3

3

21

1,120

220

593

691

721

320

Page 20: Fujitsu 2012 catalog

039038

Floor

Power Source

Capacity

Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)

Piping Connections (Small / Large)Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Height Difference

Refrigerant

Net Dimension H x W x D

OperationRange

CoolingHeating

Cooling/HeatingCoolingHeating

Cooling/Heating

CoolingHeating

CoolingIndoor/Outdoor

Indoor

Outdoor

Cooling H/M/L/Q

m

°CDB

kg(lbs)mm

kg(lbs)mmmm

mm

dB(A)

kW

kW

W/W

AI/h

m3/h

V/Ø/Hz

AGYF09LA

AOYV09LA

230/1/502.60(0.9~3.5)3.50(0.9~5.5)

0.53/0.794.91-A4.43-A2.6/3.8

1.3 40/35/29/22

47570/1680

600x740x200

14(31)540x790x290

36(79)6.35/9.52

13.8/15.8 to 16.720(15)

15 -10~43-15~24R410A

AGYF12LA

AOYV12LA

230/1/503.50(0.9~4.0)4.50(0.9~6.6)

0.94/1.193.72-A3.78-A4.4/5.5

1.8 40/35/29/22

48570/1680

600x740x200

14(31)540x790x290

36(79)6.35/9.52

13.8/15.8 to16.720(15)

15-10~43-15~24R410A

AGYF14LA

AOYV14LA

230/1/504.20(0.9~5.0)5.20(0.9~8.0)

1.14/1.443.68-A3.61-A5.2/6.4

2.1 44/38/31/22

50650/1910

600x740x200

14(31)578x790x300

40(88)6.35/12.7

13.8/15.8 to 16.720(15)

15-10~43-15~24R410A

Indoor unit

Outdoor unitModel No.

Specifications Dimensions Models: (Unit : mm)AGYF09LA / AGYF12LA / AGYF14LA

Flexible & easy installation

AGYF09LA AGYF12LA AGYF14LA

CLASSA

ALLDC

CLASSA

ALLDC

CLASSA

ALLDC

Simple & Thin design harmonizes with the interior

For AGYF09/12LA For AGYF14LA

Cooling

at operationstart

at operationstart

Heating WindowPrevents cold draft from window

at stableoperation

Prevents cold air from falling

at stableoperation

Beneathstandard window

Standard concaveportion Wall Half concealed

(Optional parts necessary)

(unit:mm)

600

740200

700

(unit:mm)

Min.700

Min. 590

Min.940

(unit:mm) (unit:mm)Max. 150

Min. 730 Max. 80

2-Fan & Wide airflow

Flexible piping connection6 direction of drain & piping

Back view

Drain hosePiping

1 62 53 4

Filter features

Long-life* Ion Deodorization Filter

Apple-catechin Filter

Using different filters at both sides

The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.

Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol extracted from apples.

(*The filter can be used for approx. 3 years if it is washed under water to restore its surface action when it is dirty.)

Apple-catechin Filter

Ion Deodorization Filter

10°C HEAT Operation

The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied

10°C

20°C

“10°C HEAT”Button ON

Indoor unitoperation START

•When the room temperature is higher than 10°C, “10°C HEAT” operation does not start. Operation starts and maintains the room temperature at 10°C when the temperature drops below 10°C.

•When “10°C HEAT” operation stops, the room set temperature quickly returns to the preset temperature.

“10°C HEAT”Button ON

Quiet operation

Industry leading noise levels

Low ambient operation

Easy maintenance

Washable panel removableRemovable panel

Optional parts

Wired Remote Controller: UTY-RNNYMHalf Concealed Kit: UTR-STAExternal Connect Kit: UTY-XWZX

50

40

30

20

10

0

-10

43°C

-15°C

Cooling

24°CHeating

-10°C

Low level

22dB(A)

Fan speed

Quiet

200

600

740

Front view

Side view

Caution

Page 21: Fujitsu 2012 catalog

041040

Compact Cassette

Specifications Dimensions Models: (Unit : mm)AUYG12LVLB / AUYG14LVLB / AUYG18LVLB / AUYF24LB

AUYG12LVLB AUYG14LVLB AUYG18LVLB

CLASSA

ALLDC

CLASSA

ALLDC

CLASSA

ALLDC

AUYF24LB

CLASSA

ALLDC

Powerful wide air flow & Quiet operation

Low ambient operation

Grille is an option

Compact Outdoor Unit

Wireless R.C.

Adoption of laminar wing

Spin direction Airflow direction

Quiet

Airflow runs through smoothly along the laminar wing

No airflow separation

Laminar wingQuiet

2-stage turbo fanHigh efficiency design by 2 stage structure

Quiet quality

Previous turbo fan 2-stage turbo fan

1-stage

+2-stage2 stage

Fast

Slow

Windvelocity In the case of a conventional

fan, the air outlet range was narrow as the airflow moved to the motor side which meant the velocity of air passing through the heat exchanger was uneven.

Designed by CFD-analysis (fluid) simulations

Optimization of wing form (laminar wing type) and wing number (7 blades each)

ABCD

Grille cover2

1

3: standard equipment

During installation, maintenance and operation, the drain pump and kit can be checked easily.

Maintenance of the fan motor and fan can be done easily after taking off the panel as the bell mouth of the fan can be removed easily.

A : Fan motorC : Bell-mouth

B : 2-stage turbo fanD : Panel

Easy maintenance

1 Maintenance of fan motor and fan

2 Long life filter

3 Adaptation of transparent drainage parts

Previous model New model

24 type

Compact designWorlds first 24,000Btu model in the compact cassette category (Easy installation by taking off ceiling panel of 600 x 600 size)

570570 570570570 570

590 590

24 type

830830

High lift drain pump

700mm

Heat exchangeefficiency:

20%UP

700

30 4970

0

530(Bolt pitch)

540(

Bol

t pitc

h)

570(

Indo

or u

nit)

580-

660(

Cei

ling

open

ings

)

75

114

215 26

230

5830 123

135 250

Control box Liquid pipe Gas pipeCeiling

Side view

Top view

Side view

Bottom view

30

9940

102

102

108

146

245

50

40

30

20

10

0

-10

-15°C

Cooling

24°CHeating

-10°C

Power Source

Capacity

Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)

Piping Connections (Small / Large)Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Height Difference

RefrigerantDecoration Panel

Net Dimension H x W x D

OperationRange

CoolingHeating

Cooling/HeatingCoolingHeating

Cooling/Heating

CoolingHeating

CoolingIndoor/Outdoor

Indoor / Grille

Outdoor

Cooling H/M/L/Q

m

°CDB

kg(lbs)mm

kg(lbs)mmmm

mm

dB(A)

kW

kW

W/W

AI/h

m3/h

V/Ø/Hz

AUYG12LVLB

AOYG12LA

230/1/503.504.10

1.05/1.113.33-A3.69-A4.8/5.1

1.2 37/34/30/27

47600/1780

245×570×570/49x700x70015(33)/2.6(6)578×790×300

40(88)6.35/9.52

25/3225(15)

15-10~46-15~24R410A

UTG-UFYD-W

AUYG14LVLB

AOYG14LA

230/1/504.305.00

1.33/1.343.21-A3.71-A6.1/6.1

1.5 38/34/30/27

49680/1910

245×570×570/49x700x70015(33)/2.6(6)578×790×300

40(88)6.35/12.70

25/3225(15)

15-10~46-15~24R410A

UTG-UFYD-W

AUYG18LVLB

AOYG18LA

230/1/505.206.00

1.62/1.663.21-A3.61-A7.2/7.4

2.2 38/34/30/26

50680/2000

245×570×570/49x700x70015(33)/2.6(6)578x790x300

40(88)6.35/12.70

25/3225(15)

15 -10~46-15~24R410A

UTG-UFYD-W

AUYF24LB

AOYA24LA

230/1/507.108.00

2.21/2.213.21-A3.61-A9.7/9.7

2.7 49/44/36/30

52930/2470

245×570×570/49x700x70017(37)/2.6(6)578x790x315

44(97)6.35/15.8819.4/26.8

30(15)20

-10~46-15~24R410A

UTG-UFYB-W

Model No.Indoor unit

Outdoor unit

46°C

Optional partsAir Outlet Shutter Plate:Wired Remote Controller:Insulation Kit For High Humidity:External Connect Kit:External Control Set:Fresh Air Intake Kit:Simple Remote Controller:

UTR-YDZBUTY-RNNYMUTZ-KXGCUTY-XWZXUTD-ECS5AUTZ-VXAAUTY-RSNYM

A evenly spread air distribution across the heat exchanger is possible due to the new 2 stage turbo fan which produces two separate airflow streams.

(12/14/18)

Page 22: Fujitsu 2012 catalog

043042

Compact Cassette

Specifications Dimensions Models: (Unit : mm)AUY18UB

AUY18UB

Optional parts

Additional Grille: UTG-AGDA-W

Compact grille fits European ceiling panel(650 x 650 mm)

Compact size

Wireless R.C.

Auto air flow direction and auto swing

Comfortable air flow

4-way

3-way2-way

Select 2-way, 3-way or 4-way air flow to suit your needs.

43

2

1

1

2

3

4

4 step swing 2-4 way air flow system

StepsAuto swing

235400

580Condensate pump lift to 400mm

Punch Hall grille

650

650

(unit: mm)

Fresh air can be introduced through this opening

Conditioned air can be distributed by means of a distribution duct1-way 2-way

Duct connection hole opening

Distribution duct

Distribution duct

Fresh air

Additional grille (optional parts)

770mm

770mm

Additional grille The ceiling hole

Indoor Unit (grille)650mm

650m

m

Power Source

Capacity

Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)

Piping Connections (Small / Large)Max Pipe Length (Pre-Charge)Height Difference

RefrigerantDecoration Panel

Net Dimension H x W x D

OperationRange

CoolingHeating

Cooling/HeatingCoolingHeating

Cooling/Heating

CoolingHeating

CoolingIndoor/Outdoor

Indoor / Grille

Outdoor

Cooling H/M/L

m

°CDB

kg(lbs)mm

kg(lbs)mm

mm

dB(A)

kW

kW

W/W

AI/h

m3/h

V/Ø/Hz

AUY18UB

AOY18UB

230/1/504.855.40

1.85/2.002.62-D2.70-E8.2/9.2

2.1 44/41/37

52620/3200

235x580x580

18(40)650x830x320

52(115)6.35/12.70

20(10)8

0~43-7~24R410A

UTG-UDYD-W

Model No.Indoor unit

Outdoor unit

20 35

66

235

650

245

580

650580

440

(Han

ging

bol

t pos

ition

)

6

06

(Hanging bolt position) 400

(Grille measurement) 650

440

131

245

54

111 47

66

46

60

86

Drain pipe(I.D 32).

600(Ceiling opening measurement)

Side view

Top view

Bottom viewBottom view (Panel)

Page 23: Fujitsu 2012 catalog

045044

Cassette

High efficiency turbo fan with 3-dimensional blade

Specifications Dimensions Models: (Unit : mm)AUYA30LB / AUYA36LB / AUYA45LC / AUYA54LC AUYG36LR /AUYG45LR / AUYG54LR

Detachable Grille corner

Adjustment can be done just taking off the corner part

450mm 500mm

WindvelocityHeat exchanger

< Motor side >

Uneven airflow

Fast

SlowConventional blade

Separation phenomenon of airflow causes noise

: Spin direction : Airflow direction : Turbulent flow noise

< Motor side >Heat exchanger

3-dimensional blade

No airflow separation

Previous turbo fan: Air passing through the heat exchanger was uneven and the air would only flow close to the ceiling.

New turbo fan: High efficiency airflow distribution has been achieved by the introduction of a 3 dimensional blade which increases the air passing over the heat exchanger.

Quiet

High lift drain pump

Optional partsWired Remote Controller:IR Receiver Kit:Wide Panel:Panel Spacer:Air Outlet Shutter Plate:Insulation Kit For High Humidity:External Connect Kit:

External Control Set:Fresh Air Intake Kit:

UTY-RNNYMUTY-LRHYA1UTG-AGYA-WUTG-BGYA-WUTR-YDZCUTZ-KXGAUTY-XWZXUTY-XWZXZ2UTY-XWZXZ3UTD-ECS5AUTZ-VXGA

Ceiling panel

850mm

Powerful wide air flow & Quiet operation

For AUYA30/36LB

Low ambient operation

Wired R.C.Grille is an option

Improvement of the airflow distribution

Adjustment of hanger position is possible after installation

New louvre: The louvre design distributes air leaving a space between the chassis and the ceiling allowing far and wide air flow distribution.

Much less temperature irregularity happens by spreading airflow widely

Bottom view

Front part Ceiling

Rear part

Round louvre

358

9813

3

118

158

288

Drain pipe

Liquid pipe

Side view

Top view

Gas pipe

338278

950

950Bottom view

890

(Cei

ling

open

ings

)

699

(Bol

t pitc

h)

796 (Bolt pitch)

842 (indoor unit)

AUYA30LB AUYA36LBAUYG36LR

CLASSA

ALLDC

CLASSA

ALLDC

AUYA45LCAUYG45LR

CLASSA

ALLDC

AUYA54LCAUYG54LR

CLASSA

ALLDC

For AUYG36/45/54LR(For 3 phase)

For AUYA45/54LC(For single phase)

50

40

30

20

10

0

-10

-15°C

Cooling

24°CHeating

46°C

-15°C

Singlephase

Capacity

EER - Energy ClassCOP - Energy Class Running CurrentMoisture Removal

Airflow Rate (High)

Noise (Indoor)

Net Dimension H x W x D

Piping Connections (Small / Large)

Height Difference

Operation RangeCoolingHeating

Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)

RefrigerantDecoration Panel

HeatingCooling/HeatingInput Power

Power Source Cooling

Cooling

Indoor / Outdoor

Cooling H/M/L/QCoolingNoise (Outdoor)

HeatingCooling/Heating

Indoor /Grille

Outdoor

°CDB

mm

m

kg(lbs)mm

mm

kW

kg(lbs)

A

W/W

m3/h

I/h

dB(A)

mm

V/ Ø/Hz

kW

AUYA30LB

AOYA30LF

230/1/508.50

10.002.65/2.77

3.21-A3.61-A

11.6/12.22.5

40/38/36/3253

1600/3600288x840x84050x950x950

26(57)/5.5(12)830x900x330

61(135)9.52/15.8825.0/32.0

50(20)30

-15~46-15~24R410A

UTG-UGYA-W

Model No.Indoor unit

Outdoor unit

AUYG36LR

AOYG36LA

400/3/5010.0011.20

2.44/2.564.10-A4.38-A3.7/3.9

3.044/39/36/33

511800/6200

288x840x84050x950x950

27(60)/5.5(12)1290×900×330

105(229)9.52/15.8825.0/32.0

75(30)30

-15~46-15~24R410A

UTG-UGYA-W

AUYA45LC

AOYA45LC

230/1/5012.5014.00

3.90/3.773.21-A3.71-A

17.0/16.54.5

46/42/40/3655

1900/6750288x840x84050x950x950

27(60)/5.5(12)1290×900×330

88(194)9.52/15.8825.0/32.0

50(20)30

-15~46-15~24R410A

UTG-UGYA-W

AUYG45LR

AOYG45LA

400/3/5012.5014.00

3.54/3.583.53-A3.91-A5.3/5.3

4.546/42/40/36

541900/6900

288x840x84050x950x950

27(60)/5.5(12)1290×900×330

105(229)9.52/15.8825.0/32.0

75(30)30

-15~46-15~24R410A

UTG-UGYA-W

AUYG54LR

AOYG54LA

400/3/5014.0016.00

4.36/4.433.21-A3.61-A6.5/6.6

5.047/43/41/37

552000/6900

288x840x84050x950x950

27(60)/5.5(12)1290×900×330

105(229)9.52/15.8825.0/32.0

75(30)30

-15~46-15~24R410A

UTG-UGYA-W

AUYA54LC

AOYA54LC

230/1/5013.316.0

4.42/4.693.01-B3.41-B

19.3/20.55.0

47/43/41/3755

2000/6750288x840x84050x950x950

27(60)/5.5(12)1290×900×330

88(194)9.52/15.8825.0/32.0

50(20)30

-15~46-15~24R410A

UTG-UGYA-W

AUYA36LB

AOYA36LF

230/1/5010.0011.20

3.12/3.023.21-A3.71-A

13.7/13.33.5

43/38/36/3254

1800/3800288x840x84050x950x950

26(57)/5.5(12)830x900x330

61(135)9.52/15.8825.0/32.0

50(20)30

-15~46-15~24R410A

UTG-UGYA-W

Low noise mode of outdoor unit (45/54 types)

2 stage low noise mode can be selected.(Option)

Roted noise value

Mode 1

Mode 2

Lownoisemode

-4dB-2dB

3phase 3phase 3phase

Page 24: Fujitsu 2012 catalog

047046

Cassette

Specifications DimensionsModels:

(Unit : mm)

AUY25UU / AUY30UU Models: AUY36UU / AUY45UU / AUY54UU

Auto air flow direction and auto swing

Comfortable airflow

4-way

3-way2-way

Select 2-way, 3-way or 4-way air flow to suit your needs.

4 step swing 2-4 way air flow system

Power Source

Capacity

Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)

Piping Connections (Small / Large)Max Pipe Length (Pre-Charge)Height Difference

Refrigerant

Net Dimension H x W x D

OperationRange

CoolingHeating

Cooling/HeatingCoolingHeating

Cooling/Heating

CoolingHeating

CoolingIndoor/Outdoor

Indoor

Outdoor

Cooling H/M/L

m

°CDB

kg(lbs)mm

kg(lbs)mm

mm

dB(A)

kW

kW

W/W

AI/h

m3/h

V/Ø/Hz

AUY25UU

AOY25UU

230/1/507.007.80

2.65/2.352.64-D3.32-C

11.8/10.52.5

44/42/3953

1100/3200

246x830x830

34(75)650x830x320

59(130)9.52/15.88

25(7.5)15

0~43-7~24R410A

AUY30UU

AOY30UU

230/1/508.409.50

2.95/2.782.85-C3.42-B

13.6/13.13.0

46/44/3953

1250/3300

246x830x830

34(75)830x900x330

69(152)9.52/15.88

30(7.5)15

0~43-7~24R410A

AUY36UU

AOY36UU

400/3/5010.5011.80

3.48/3.653.02-B3.23-C5.9/6.2

4.0 48/44/41

541500/6100

296x830x830

37(82)1165x900x330

94(207)9.52/15.88

50(20)30

0~43-10~24R410A

AUY45UU

AOY45UU

400/3/5012.7014.30

4.38/4.392.90 3.26

7.7/7.75.0

49/47/4354

1550/6100

296x830x830

40(88)1165x900x330

113(249)9.52/19.05

50(20)30

0~43-10~24R410A

AUY54UU

AOY54UU

400/3/5014.5016.50

5.16/5.302.813.11

9.5/9.56.0

52/48/4554

1700/6300

296x830x830

40(88)1290x900x330

118(260)9.52/19.05

50(20)30

0~43-10~24R410A

Model No.Indoor unit

Outdoor unit

StepsAuto Swing

4 3 2 14321

Wide air flowLarger air flap distributes the outlet air flow a longer distance in the horizontal direction.

Flexible installation

Installation is done by “Standard setting“ with more than 300mm (250mm) of space. “Slender setting” lets it suitable for minimum 265mm (215mm) installation space.

Condensate pump lift to 800mm

Optional partsSimple Remote Controller:Additional Grille:

UTY-RSNYMUTG-AGEA-W

ceiling panel

800mm

AUY25UU AUY30UU AUY36UU AUY45UU AUY54UU

Wired R.C.For AUY25UU For AUY30UU

For AUY36/45UU For AUY54UU

Standard setting

Standard setting

Slender setting

250mm 300mm

215mm 265mm

25UU/30UU 36UU/45UU/54UU

Slender settingInstallation Space (Built-in measurement)

Structural objects Structural objects

265300

Ceiling Ceiling

Duct connection hole opening

Fresh air can be introduced through this opening

Conditioned air can be distributed by means of a distribution duct

2-way1-way

Distributionduct

Distribution duct

Fresh air

Easy maintenance

Detachable, washable filter and intake grille

Wide opening and long-life filter

Long-life filter

Long-life filter

High efficiency, long-life filter extends the cleaning cycle.

The control box is easily accessible for maintenance work.Wide opening for easy access.

By placing the electrical component box inside the unit easy maintenance is assured.

(Service staff)

305.5298.5

248.5

200

60 (Dra

inpi

pe)

100

(Sm

a llp

ipe)

70 (Lar

gepi

pe)

305.5298.5

248.5

235

60 (Dra

inp i

pe) Drain inside Dia. ø32

outside Dia. ø37

100

(Sm

allp

ipe )

70 (Lar

gepi

pe)

940

246

30

940 830

830

30

296

750

940

60

(Dra

in p

ipe)

120

285

(Sm

all p

ipe)

150

(Lar

ge p

ipe)

(Sm

all p

ipe)

(Lar

ge p

ipe)

940

830

830

298.5

305.5 248.5

60

(Dra

in p

ipe)

120

250

150

298.5

305.5 248.5

Drain Inside Dia. 32OutsideDia. 37

750

Page 25: Fujitsu 2012 catalog

049048

Floor/Ceiling Universal

Specifications Dimensions Models: (Unit : mm)ABYG18LVTB / ABYF24LB

Floor console

Flexible installation

Under ceiling

Example for floor installation Example for ceiling installation

Right and Left Swing

1

2

5

43

5 steps selectable

StepsSwing: Cooling , Dry and Fan modeSwing: Heating and Fan mode

Up and Down Swing1

2

5

4

3

7 steps selectable

6

7

Main work settings can be done easily from the remote controllerat installation

Main work settingsHigh ceiling settingAuto restart Temperature adjustment when cooling / heating

Easy installation

Power Source

Capacity

Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)

Piping Connections (Small / Large)Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Height Difference

Refrigerant

Net Dimension H x W x D

OperationRange

CoolingHeating

Cooling/HeatingCoolingHeating

Cooling/Heating

CoolingHeating

CoolingIndoor/Outdoor

Indoor

Outdoor

Cooling H/M/L/Q

m

°CDB

kg(lbs)mm

kg(lbs)mmmm

mm

dB(A)

kW

kW

W/W

AI/h

m3/h

V/Ø/Hz

ABYG18LVTB

AOYG18LA

230/1/505.206.00

1.62/1.663.21-A3.61-A7.2/7.4

2.043/40/34/31

50780/2000

199x990x655

27(60)578x790x300

40(88)6.35/12.70

25/3225(15)

15 -10~46-15~24R410A

ABYF24LB

AOYA24LA

230/1/507.108.00

2.21/2.213.21-A3.61-A9.7/9.7

2.7 48/44/40/35

52980/2470

199x990x655

27(60)578x790x315

44(97)6.35/15.88

25/29.830(15)

20-10~46-15~24R410A

Model No.Indoor unit

Outdoor unit

Double auto swing

A combination of right/left and up/down directional swing allows 3-dimensional air direction control

ABYG18LVTB ABYF24LB

CLASSA

ALLDC

CLASSA

ALLDC

Wireless R.C.

Low ambient operation

Optional parts

Wired Remote Controller:Simple Remote Controller:External Connect Kit:

UTY-RNNYM UTY-RSNYMUTY-XWZX

50

40

30

20

10

0

-10

-15°C

Cooling

24°CHeating

-10°C

46°C

Refrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)Drain piping connection

21

3

12

1

2

33

(18)

Page 26: Fujitsu 2012 catalog

051050

Floor/Ceiling Universal

Specifications Dimensions Models: (Unit : mm)

Floor console

Flexible installation

Under ceiling

Example for floor installation Example for ceiling installation

(Unit : mm)

When operation is stopped, the louvres will automatically close. (This function is available on all non-ducted models.)

990 199

655

Symmetrical, slim and compact design.

Compact design

UP and DOWN SWING

RIGHT and LEFT SWING

7 steps selectable

Auto-closing louvre1

2

5

43

12

5

43

6

7

Power Source

Capacity

Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)

Piping Connections (Small / Large)Max Pipe Length (Pre-Charge)Height Difference

Refrigerant

Net Dimension H x W x D

OperationRange

CoolingHeating

Cooling/HeatingCoolingHeating

Cooling/Heating

CoolingHeating

CoolingIndoor/Outdoor

Indoor

Outdoor

Cooling H/M/L

m

°CDB

kg(lbs)mm

kg(lbs)mm

mm

dB(A)

kW

kW

W/W

AI/h

m3/h

V/Ø/Hz

ABY18UB

AOY18UB

230/1/505.406.00

1.9/1.852.84-C3.24-C8.6/8.3

2.0 46/41/37

52780/3200

199x990x655

28(62)650x830x320

52(115)6.35/15.88

20(7.5)8

0~43-6~24R410A

ABY24UB

AOY24UB

230/1/506.507.40

2.42/2.302.69-D3.22-C

10.8/10.32.5

49/45/4153

880/3200

199x990x655

28(62)650x830x320

59(130)9.52/15.88

20(7.5)8

0~43-6~24R410A

Model No.Indoor unit

Outdoor unit

ABY18UB ABY24UB

Wireless R.C.

Double auto swing

A combination of up/down and right/left directional swing allows three-dimensional air direction control.

Super vane

Double Louvre Super vane with newly developed special configuration boosts airflow sending cool air quickly to every corner of the room.

Refrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)Drain piping connection

21

3

12

1

2

33

ABY18UB / ABY24UB

Page 27: Fujitsu 2012 catalog

053052

Ceiling

Installation Multi auto swing

Specifications Dimensions Models: (Unit : mm)ABYA30LB / ABYA36LB / ABYA45LCABYG36LR / ABYG45LR / ABYG54LR

Optional partsWired Remote Controller:Drain Pump Unit:External Connect Kit:

External Control Set:Flange:

UTY-RNNYMUTR-DPB24TUTY-XWZXUTY-XWZXZ2UTY-XWZXZ3UTD-ECS5AUTD-RF204

ABYA30LB ABYA36LBABYG36LR

CLASSA

ALLDC

CLASSA

ALLDC

ABYA45LCABYG45LR

CLASSA

ALLDC

ABYA54LCABYG54LR

CLASSA

ALLDC

Easily concealed in any installation

Low ambient operation

Condensate lift-up mechanism (Option)

Optional drain lift-up mechanism allows flexible installation.

A combination of right/left and up/down directional swing allows 3-dimensional air direction control.

StepsSwing: Cooling , Dry and Fan modeSwing: Heating and Fan mode

Wireless R.C.

Refrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)Drain piping connection

21

3

For ABYA30/36LB

For ABYA45LC(For single phase)

For ABYG36/45/54LR(For 3 phase)

Right and Left Swing Up and Down Swing

5 steps selectable 5 steps selectable

1

2

5

4

3

12

54

3

(Field Supplied)

Open Concealed

Wall mounted Fresh air intake

OutdoorIndoor

Freshair

Max.

500mm

Easy installation

Main work settings can be done easily from the remote controller at installation

Setting by wireless or wired remote controller

Conventional type

1 2 3

O F F

SW1(Optional parts)

Setting by DIP switch inside control box

Main work settings•High ceiling setting•Auto restart •Temperature adjustment when cooling / heating

1 32

3

Capacity

EER - Energy Class

Running CurrentMoisture Removal

Airflow Rate (High)

Noise (Indoor)

Net Dimension H x W x D

Piping Connections (Small / Large)

Height Difference

Operation Range CoolingHeating

Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)

Refrigerant

HeatingCooling/HeatingInput Power

Power SourceCooling

Cooling

Indoor / Outdoor

Cooling H/M/L/QCoolingNoise (Outdoor)

HeatingCooling/Heating

Indoor

Outdoor

°CDB

mm

m

kg(lbs)mm

mm

kW

kg(lbs)

A

W/W

m3/h

I/h

dB(A)

mm

V/ Ø/Hz

kW

ABYA30LB

AOYA30LF

230/1/508.50

10.002.65/2.77

3.21-A3.61-A

11.6/12.22.5

45/43/37/3253

1660/3600240×1660×700

46(101)830x900x330

61(135)9.52/15.8822.0/25.6

50(20)30

-15~46-15~24R410A

Model No.Indoor unit

Outdoor unit

ABYA36LB

AOYA36LF

230/1/509.4011.20

2.93/3.023.21-A3.71-A

12.8/13.23.0

47/43/37/3254

1900/3800240×1660×700

46(101)830x900x330

61(135)9.52/15.8822.0/25.6

50(20)30

-15~46-15~24R410A

ABYG36LR

AOYG36LA

400/3/5010.0011.20

2.84/2.873.52-A3.9-A

4.3/4.43.0

47/43/37/3251

1900/6200240x1660x700

46(101)1290×900×330

105(229)9.52/15.8822.0/25.6

75(30)30

-15~46-15~24R410A

ABYA45LC

AOYA45LC

230/1/5012.0013.30

3.74/3.683.21-A3.61-A

16.4/16.14.5

49/45/39/3455

2100/6750240×1660×700

46(101)1290×900×330

88(194)9.52/15.8822.0/25.6

50(20)30

-15~46-15~24R410A

ABYG45LR

AOYG45LA

400/3/5012.5014.00

3.89/3.883.21-A3.61-A5.8/5.8

4.549/45/39/34

542100/6900

240x1660x70046(101)

1290×900×330105(229)

9.52/15.8822.0/25.6

75(30)30

-15~46-15~24R410A

ABYG54LR

AOYG54LA

400/3/5014.0016.00

4.65/4.673.01-B3.43-B6.9/6.9

5.051/48/42/38

552300/6900

240x1660x70048(106)

1290×900×330105(229)

9.52/15.8822.0/25.6

75(30)30

-15~46-15~24R410A

50

40

30

20

10

0

-10

-15°C

Cooling

24°CHeating

46°C

-15°C

Singlephase

Low noise mode of outdoor unit (45/54 types)2 stage low noise mode can be selected.(Option)

Roted noise value

Mode 1

Mode 2

Lownoisemode

-4dB-2dB

3phase

Page 28: Fujitsu 2012 catalog

055054

Ceiling

Specifications Dimensions Models: (Unit : mm)ABY30UB /ABY36UB / ABY45UB / ABY54UB

Installation

Optional drain lift-up mechanism allows flexible installation.

Condensate lift-up mechanism (Option)

Power Source

Capacity

Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)

Piping Connections (Small / Large)Max Pipe Length (Pre-Charge)Height Difference

Refrigerant

Net Dimension H x W x D

OperationRange

CoolingHeating

Cooling/HeatingCoolingHeating

Cooling/Heating

CoolingHeating

CoolingIndoor/Outdoor

Indoor

Outdoor

Cooling H/M/L

m

°CDB

kg(lbs)mm

kg(lbs)mm

mm

dB(A)

kW

kW

W/W

AI/h

m3/h

V/Ø/Hz

ABY54UB

AOY54UB

400/3/5014.5016.50

5.16/5.302.813.11

9.5/9.56.0

52/50/4654

2200/6300

240x1660x700

48(106)1290x900x330

118(260)9.52/19.05

50(20)30

0~43-10~24R410A

ABY45UB

AOY45UB

400/3/5012.7014.30

4.38/4.392.90 3.26

7.7/7.75.0

48/46/4154

1850/6100

240x1660x700

48(106)1165x900x330

113(249)9.52/19.05

50(20)30

0~43-10~24R410A

ABY36UB

AOY36UB

400/3/5010.5011.80

3.48/3.453.02-B3.42-B5.9/6.2

4.0 45/42/37

541660/6100

240x1660x700

48(106)1165x900x330

94(207)9.52/15.88

50(20)30

0~43-10~24R410A

ABY30UB

AOY30UB

230/1/508.409.50

2.95/2.782.85-C3.42-B

13.6/13.13.0

42/39/3553

1450/3300

240x1660x700

48(106)830x900x330

69(152)9.52/15.88

30(7.5)15

0~43-7~24R410A

Model No.Indoor unit

Outdoor unit

ABY30UB ABY36UB ABY45UB

Double auto swing and wide airflow

Auto airflow direction and auto swing

Slim & Compact design

ABY54UB

For ABY30UB For ABY36/45UB For ABY54UB

Wireless R.C.

General installation pattern which suspends the indoor unit from the ceiling.

Open

Installation pattern where part of the indoor unit is embedded into the ceiling.

Concealed

Installation which fixes the indoor unit to the wall by the use of wall brackets (Field supplied). This type of installation can be used when the ceiling space is insufficient.

(Field Supplied)

Wall mounted

5 steps selectable

Right and left

1

2

3

45

5 steps selectable

Up and Down Swing

Long Airflow

Long distance air-flow

Long Airflow ensures comfort to every corner of a large room.

High efficiency long-life filter doubles the life of the filter compared to standard filters.

Fresh air intake

240

Long-life filter

OutdoorIndoor

Freshair

Optional parts

Drain Pump Unit: Flange:

Max.

500mm

Refrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)Drain piping connection

21

31 32

3

UTR-DPB24TUTD-RF204

Page 29: Fujitsu 2012 catalog

057056

Slim Duct

Specifications Dimensions Models: (Unit : mm)ARYG12LLTB / ARYG14LLTB / ARYG18LLTB

Power Source

Capacity

Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)

Piping Connections (Small / Large)Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Height Difference

Refrigerant

Net Dimension H x W x D

OperationRange

CoolingHeating

Cooling/HeatingCoolingHeating

Cooling/Heating

CoolingHeating

CoolingIndoor/Outdoor

Indoor

Outdoor

Cooling

m

°CDB

kg(lbs)mm

kg(lbs)mmmm

mm

dB(A)

kW

kW

W/W

AI/h

m3/h

V/Ø/Hz

ARYG14LLTB

AOYG14LA

198x700x620

19(42)578x790x300

40(88)6.35/12.70

25/3225(15)

15-10~46-15~24R410A

230/1/504.305.00

1.33/1.343.21-A3.71-A6.1/6.1

1.5 32/30/28/26

49800/1910

ARYG18LLTB

AOYG18LA

198x900x620

23(51)578x790x300

40(88)6.35/12.70

25/3225(15)

15-10~46-15~24R410A

230/1/505.206.00

1.62/1.663.21-A3.61-A7.2/7.4

2.0 32/30/29/27

50940/2000

Model No.Indoor unit

Outdoor unit

ARYG12LLTB ARYG14LLTB

CLASSA

ALLDC

CLASSA

ALLDC

ARYG18LLTB

CLASSA

ALLDC

Optional parts

Wired Remote Controller:Simple Remote Controller:IR Receiver Unit:Remote Sensor Unit:External Control Set:Auto Louver Grille Kit:

UTY-RNNYMUTY-RSNYMUTY-LRHYMUTY-XSZXUTD-ECS5AUTD-GXSA-W (For ARYG12 / 14LLTB)

UTD-GXSB-W (For ARYG18LLTB)

*Service accessibility must be allowed for when installing the product. Please consult the installation manual for the necessary service access size.

Wired R.C.

• Slim design with drain pump• Increase static pressure range• Dual concealed type

(Bol

t pitc

h)

F51

152

377

174

713030

ABCD

EF

700650734650

P100x6=600574

ARYG12 / 14LLTB900850934850

P100x8=800774

ARYG18LLTB

78

50

EDC

(Bolt pitch)

43

20

198

168

78

BA

12

69144263371

620

47557889119

167

Air-intake

Back sideBottom side

Air intake direction can be selected to match the installation site.

Slim design

Drain port

This model is slim design, it can install at the place where a ceiling is narrow.

Drain pumpbuilt-in

Height198mm

Drain pump

Drain hose is standard accessory

Max.850mm

Filter (Accessory) Filter (2pcs.)

Flexible installation

Floor concealed

Ceiling concealed

Auto Louver Grille Kit (Option)

Simple flat Auto Louver will provide comfort airflow and harmonize with luxury interior.

Drain pump is standard accessory

It allows flexible installation.

Selectable with a wide range of static pressure

By using DC fan motor, it is possible to change the static pressure range0 to 90Pa. The change of static pressure range is possible by remote controller.

Static pressure range0 to 90 Pa

Wired RemoteController

Wireless RemoteController

4 steps selectable and auto swing

Auto Louver Grille Duct type

Compact Outdoor Unit

ARYG12LLTB

AOYG12LA

230/1/503.504.10

1.05/1.113.33-A3.69-A4.8/5.1

1.3 29/28/26/25

47650/1780

198x700x620

19(42)578x790x300

40(88)6.35/9.52

25/3225(15)

15-10~46-15~24R410A

H/M/L/Q

Page 30: Fujitsu 2012 catalog

059058

Compact Duct

Specifications Dimensions Models: (Unit : mm)

Flexible installation

Slim size (217mm) allows installation even where the space behind the ceiling is narrow.

Two-direction drain piping

Air-intake

Filter (Accessory)

Back sideBottom side

Filter (3pcs.)

Air intake direction can be selected to match the installation site.

217

Floor concealed

Ceiling concealed

Two-direction drain pipingDuct indoor unit

ARY18UU

Refrigerant piping flare connection (Gas)Refrigerant piping flare connection (Liquid)Drain piping connection

21

3

*Service accessibility must be allowed for when installing the product. Please consult the installation manual for the necessary service access size.

2

13

Control box

Brackets

Brackets

Airflow outlet

Control box

886(Bolt pitch)

(Bol

t pitc

h)850

390

166

595

2024 47

85

587

194

150

7565

344

953

60094

1021

715

0

886

167

217

Power Source

Capacity

Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)

Piping Connections (Small / Large)Max Pipe LengthHeight Difference

Refrigerant

Net Dimension H x W x D

OperationRange

CoolingHeating

Cooling/HeatingCoolingHeating

Cooling/Heating

CoolingHeating

CoolingIndoor/Outdoor

Indoor

Outdoor

Cooling H/M/L

m

°CDB

kg(lbs)mm

kg(lbs)mm

mm

dB(A)

kW

kW

W/W

AI/h

m3/h

V/Ø/Hz

ARY18UU

AOY18UU

230/1/505.406.00

1.92/1.872.81-C3.21-C8.8/8.7

1.6 43/40/36

521000/3200

217x953x595

25(55)650x830x320

52(115)6.35/15.88

208

0~43-6~24R410A

Model No.Indoor unit

Outdoor unit

Compact design

Ultra-slim duct air conditioner for easy installation

ARY18UU

Optional parts

Remote Sensor Unit: UTD-RS100 / UTY-XSZXIR Receiver Unit: UTY-LRJY1Drain Pump Unit: UTZ-PX1BBA

Wired R.C.

Universal Type

Max. length : 10m

IR Receiver unitWireless R.C.

Optional function for comfort

Optional parts

(Bolt pitch)

Page 31: Fujitsu 2012 catalog

061060

Medium Static Pressure Duct

Low ambient operation

Slim & Compact design

Specifications Dimensions Models: (Unit : mm)ARYF24LB / ARYA30LB / ARYA36LB / ARYA45LC ARYG36LM / ARYG45LM

In the case of bottom return air connection, not only does the indoor unit design allow for installation in a narrow ceiling space of up to 270mm, Further space savings have been achieved by mounting the electrical control box internally inside the chassis.

Optional partsWired Remote Controller:Flange (Round):Flange (Square):Long Life Filter:Remote Sensor Unit:External Connect Kit:

External Control Set:Drain Pump Unit:IR Receiver Unit:

UTY-RNNYMUTD-RF204UTD-SF045TUTD-LF25NAUTY-XSZXUTY-XWZXZ2UTY-XWZXZ3UTD-ECS5AUTZ-PX1NBAUTY-LRHY1

Wired R.C.

(24) (30/36/45)Singlephase

Easy maintenance

See below for the case of rear suction type

Structural improvement is attained by making the bottom panel two pieces, front and rear. The internal fan casing is also manufactured in two pieces, namely upper and lower. The maintenance of the motor and fan can be easily carried out by removing the rear panel and the lower part of the casing while leaving the main chassis installed.

Two-direction drain piping

Easy installation

Main work settings can be done easily from the remote controller at installation

Setting by wired remote controller Conventional type

1 2 3

O F F

SW1

Setting by DIP switch inside control box

Main work settings•High ceiling setting•Auto restart •Temperature adjustment when cooling / heating

1.Control box2.Fan casing3.Fan4.Motor

Previous model

2

4

13

Large bottom panel: 1 piece

New model 1

4

32

Bottom panel: 2 pieces

1,135mm

1,200mm

270mm

Control box is now included as part of the main chassis

One touch operating and easy to install long life filter (Optional Parts)

For ARYG36/45LM(For 3 phase)

Two-direction drain pipingDuct indoor unit

Refrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)Drain piping connection

21

3

Rear view

Top viewSide view (R)Side view (L)

Front view

2402701071015

1135

17316

1

447(

Bol

t pitc

h)

1177(Bolt pitch)Outlet270

32ø200

(knock out hole)

240

121

P.C.D. ø225

1146632

1

3

3

2

168

281

240

700

138

138

264 264 264

ø205 hole

82

75

ARYF24LB ARYA30LB

CLASSA

ALLDC

CLASSA

ALLDC

ARYA36LBARYG36LM

CLASSA

ALLDC

CLASSA

ALLDC

ARYA45LCARYG45LM

Capacity

EER - Energy ClassCOP - Energy Class Running CurrentMoisture Removal

Airflow Rate (High)

Noise (Indoor)

Net Dimension H x W x D

Piping Connections (Small / Large)

Height Difference

Operation RangeCoolingHeating

Drain Pipe Diameter (I.D./O.D.)Max Pipe Length(Pre-Charge)

Refrigerant

HeatingCooling/HeatingInput Power

Power SourceCooling

Cooling

Indoor / Outdoor

Cooling H/M/L/QCoolingNoise (Outdoor)

HeatingCooling/Heating

Indoor

Outdoor

°CDB

mm

m

kg(lbs)mm

mm

kW

kg(lbs)

A

W/W

m3/h

I/h

dB(A)

mm

V/ Ø/Hz

kW

ARYF24LB

AOYA24LA

230/1/507.108.00

2.21/2.213.21-A3.61-A9.7/9.7

2.531/29/27/25

521100/2470

270x1135x70038(84)

578x790x31544(97)

6.35/15.8836.0/38.0

30(15)20

-10~46-15~24R410A

Model No.Indoor unit

Outdoor unit

ARYA30LB

AOYA30LF

230/1/50 8.50

10.00 2.65/2.68

3.21-A 3.73-A

11.6/11.7 2.5

42/37/32/29 53

2100/3600 270x1135x700

40(88) 830x900x330

61(135) 9.52/15.88 36.0/38.0

50(20) 30

-15~46 -15~24 R410A

ARYA36LB

AOYA36LF

230/1/50 9.40 11.20

2.93/3.1 3.21-A 3.61-A

12.8/13.6 3.0

42/37/32/29 54

2100/3800 270x1 40(88)

830x900x330 61(135)

9.52/15.88 36.0/38.0 50(20)

30 -15~46 -15~24 R410A

ARYG36LM

AOYG36LA

400/3/50 10.00 11.20

2.84/2.87 3.52-A 3.90-A 4.3/4.4

3.0 40/36/31/26

51 1850/6200

270x1135x700 40(88)

1290x900x330 105(229)

9.52/15.88 36.0/38.0 75(30)

30 -15~46 -15~24 R410A

ARYA45LC

AOYA45LC

230/1/50 12.0013.30

3.74/3.68 3.21-A 3.61-A

16.4/16.1 4.5

42/38/32/28 55

2100/6750 270x1135x700

40(88) 1290×900×330

88(194) 9.52/15.88 36.0/38.0 50(20)

30 -15~46 -15~24 R410A

AOYG45LA

400/3/50 12.50 14.00

3.89/3.88 3.21-A 3.61-A 5.8/5.8

4.5 42/38/32/28

54 2100/6900

270x1,135x700 40(88)

1290×900×330 105(229)

9.52/15.88 36.0/38.0 75(30)

30 -15~46 -15~24 R410A

ARYG45LM

For ARYA45LC(For single phase)

For ARYF24LB For ARYA30/36LB

50

40

30

20

10

0

-10

-15°C

Cooling

24°CHeating

46°C

-15°C-10°C (24 type only)

3phase 3phase

Page 32: Fujitsu 2012 catalog

063062

Medium Static Pressure Duct

Specifications Dimensions Models: (Unit : mm)ARY25UU / ARY30UU / ARY36U(1) / ARY36UU / ARY45UU

Easy maintenanceTwo-direction drain piping

Two-direction drain piping

Duct indoor unit

See below for the case of rear suction type

1.Control box2.Fan casing

3.Fan4.Motor

Previous model

2

4

13

Large bottom panel: 1 piece

New model 1

4

32

Bottom panel: 2 pieces

Structural improvement is attained by making the bottom panel two pieces, front and rear. The internal fan casing is also manufactured in two pieces, namely upper and lower. The maintenance of the motor and fan can be easily carried out by removing the rear panel and the lower part of the casing while leaving the main chassis installed.

Installation styles

Embedded in Ceiling

Hanging from Ceiling

Power Source

Capacity

Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)

Piping Connections (Small / Large)Max Pipe Length (Pre-Charge)Height Difference

Refrigerant

Net Dimension H x W x D

OperationRange

CoolingHeating

Cooling/HeatingCoolingHeating

Cooling/Heating

CoolingHeating

CoolingIndoor/Outdoor

Indoor

Outdoor

Cooling H/M/L

m

°CDB

kg(lbs)mm

kg(lbs)mm

mm

dB(A)

kW

kW

W/W

AI/h

m3/h

V/Ø/Hz

ARY25UU

AOY25UU

230/1/507.007.70

2.65/2.332.64-D3.30-C

11.8/10.52.5

38/36/3453

1100/3200

270x1135x700

43(95)650x830x320

59(130)9.52/15.88

25(7.5)15

0~43-7~24R410A

ARY30UU

AOY30UU

230/1/508.409.50

2.99/2.632.81-C3.61-A

14.0/12.43.0

40/38/3653

1400/3300

270x1135x700

43(95)830x900x330

69(152)9.52/15.88

30(7.5)15

0~43-7~24R410A

ARY36U(1)

AOY36UU(1)

230/1/5010.5012.70

3.60/3.652.92-C3.48-B

16.0/16.53.5

43/41/3954

1750/6100

270x1135x700

43(95)1165x900x330

98(216)9.52/15.88

50(20)30

0~43-10~24R410A

ARY36UU

AOY36UU

400/3/5010.5012.70

3.60/3.652.92-C3.48-B6.1/6.2

3.5 43/41/39

541750/6100

270x1135x700

43(95)1165x900x330

94(207)9.52/15.88

50(20)30

0~43-10~24R410A

ARY45UU

AOY45UU

400/3/5012.7014.30

4.38/4.392.90 3.26

7.7/7.75.0

44/42/4054

1800/6100

270x1135x700

45(99)1165x900x330

113(249)9.52/19.05

50(20)30

0~43-10~24R410A

Model No.Indoor unit

Outdoor unit

ARY25UU ARY30UU ARY36U(1)ARY36UU

Optional parts

Simple Remote Controller: UTY-RSNYMRemote Sensor Unit: UTY-XSZXDrain Pump Unit: UTZ-PX1NBALong Life Filter: UTD-RF204 / UTD-SF045TExternal Control Set: UTD-ECS5A

ARY45UU

For ARY25UU For ARY36U(1)/36/45UU

Wired R.C.

For ARY30UU

*Service accessibility must be allowed for when installing the product. Please consult the installation manual for the necessary service access size.

Refrigerant piping flare connection (Liquid) : Refrigerant piping flare connection (Gas) : Drain piping connection (Drain pipe)

21

3 Rear view

Top viewSide view (R)Side view (L)

Front view

2402701071015

1135

17316

1

447(

Bol

t pitc

h)

1177(Bolt pitch)Outlet270

32ø200

(knock out hole)

240

121

P.C.D. ø225

1146632

1

3

3

2

168

281

240

700

138

138

264 264 264

ø205 hole

82

75

Slim & Compact design

In the case of bottom return air connection, not only does the indoor unit design allow for installation in a narrow ceiling space of up to 270mm, Further space savings have been achieved by mounting the electrical control box internally inside the chassis.

1,135mm

1,200mm

270mm

Control box is now included as part of the main chassis

One touch operating and easy to install long life filter (Optional Parts)

Page 33: Fujitsu 2012 catalog

065064

High Static Pressure Duct

Specifications Dimensions Models: (Unit : mm)ARYC45LC / ARYG45LH / ARYC54LC / ARYG54LH

Easy installation (Compact size & Lightweight)Easy installation & maintenance

Low noiseDesign also corresponding to high static pressure

Low ambient operation

Power Source

Capacity

Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)

Piping Connections (Small / Large)Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Height Difference

Refrigerant

Net Dimension H x W x D

OperationRange

CoolingHeating

Cooling/HeatingCoolingHeating

Cooling/Heating

CoolingHeating

CoolingIndoor/Outdoor

Indoor

Outdoor

Cooling H/M/L

m

°CDB

kg(lbs)mm

kg(lbs)mmmm

mm

dB(A)

kW

kW

W/W

AI/h

m3/h

V/Ø/Hz

ARYC45LC

AOYA45LC

230/1/5012.5014.00

4.30/3.802.91-C3.68-A

18.9/16.71.5

47/43/4055

3350/6750

400x1050x500

46(101)1290x900x330

88(194)9.52/15.8823.4/25.4

50(20)30

-15~46-15~24R410A

ARYG45LH

AOYG45LA

400/3/5012.5014.00

4.06/3.673.08-B3.81-A6.1/5.5

1.547/43/40

543350/6900

400x1050x500

46(101)1290x900x330

105(229)9.52/15.8823.4/25.4

75(30)30

-15~46-15~24R410A

ARYC54LC

AOYA54LC

230/1/5013.4016.00

4.77/4.692.81-C3.41-B

20.9/20.52.5

47/43/4055

3350/6750

400x1050x500

46(101)1290x900x330

88(194)9.52/15.8823.4/25.4

50(20)30

-15~46-15~24R410A

ARYG54LH

AOYG54LA

400/3/5014.0016.00

4.65/4.373.01-B3.66-A6.9/6.5

2.547/43/40

553350/6900

400x1050x500

46(101)1290x900x330

105(229)9.52/15.8823.4/25.4

75(30)30

-15~46-15~24R410A

Model No.Indoor unit

Outdoor unit

Singlephase

ARYC45LCARYG45LH

ARYC54LCARYG54LH

Optional parts

Wired Remote Controller:Simple Remote Controller:Long-Life Filter:External Connect Kit:

External Control Set:IR Receiver Unit:

UTY-RNNYMUTY-RSNYMUTD-LF60KAUTY-XWZXZ2UTY-XWZXZ3UTD-ECS5AUTY-LRHY1

Wired R.C.

A compact size and lightweight indoor unit has been developed by reducing the basic chassis and the overall material weight.

•4 directions piping connection•Error & operating information are explained by LED display.

Previous model : 75kg

400

8001,250(unit: mm)

400

5001,050

New model : 46kg

Heat exchanger

Plastic fan

Casing (Plastic)

ø225mm

Cutting off the corners has enabled less turbulent air flow.Low noise is realized by adopting a plastic case and a plastic fan.

For ARYC45/54LC(For single phase)

For ARYG45/54LH(For 3 phase)

50

40

30

20

10

0

-10

-15°C

Cooling

24°CHeating

46°C

-15°C

Indoor unit

2 stage low noise mode can be selected.(Option)

Outdoor unit

Roted noise value

Mode 1

Mode 2

Lownoisemode

-4dB-2dB

Volume

down47.5%

Weight

down40%

MAX.

250pa

Front view

Top viewSide view (L)

Side view (R)

Rear view

88

4001,080(Bolt pitch)

1,000862

8511,050 85

371356

208

41 123

139108

1

2

3

4

324 14

295

585

500(

Bol

t pitc

h)

71

Refrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)Drain piping connection

21

3

Med. noise level

43 dB(A)

3phase 3phase

Page 34: Fujitsu 2012 catalog

067066

High Static Pressure Duct

Specifications DimensionsModel:

(Unit : mm)

ARY60UU

Model: ARY90TL

1.Wired Remote Controller with Thermo Sensor

1 2 3

• Room temperature sensor selection• WEEKLY timer• Temperature SET BACK timer• Group control system

• Energy saving• Auto changeover (for heating)• Hot start (for heating)

• Child lock• Dual remote controllers <Optional parts>• AUTO restart

3.Remote Sensor (Optional Parts)

Long life filter (Optional Parts)

Output port (Built-in)

Pursuance of amenity performance

Various remote controllers and sensors can be selected

2.Simple Remote Controller (Optional Parts)

Power Source

Capacity

Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)

Piping Connections (Small / Large)Max Pipe Length (Pre-Charge)Height Difference

Refrigerant

Net Dimension H x W x D

OperationRange

CoolingHeating

Cooling/HeatingCoolingHeating

Cooling/Heating

CoolingHeating

CoolingIndoor/Outdoor

Indoor

Outdoor

Cooling H/M/L

m

°CDB

kg(lbs)mm

kg(lbs)mm

mm

dB(A)

kW

kW

W/W

AI/h

m3/h

V/Ø/Hz

ARY60UU

AOY60UU

400/3/5016.5019.50

6.06/5.542.723.52

10.2/9.84.0

49/45/4254

3500/6300

400x1050x500

50(110)1290x900x330

118(260)9.52/19.05

50(20)30

0~43-10~24R410A

ARY90TL

AOY90TL

380-415/3/5024.80-25.4028.90-29.50

12.2/12.22.03-2.032.37-2.3619.5/19.5

7.5 50 59

4300/9800

450x1550x700

85(187)1380x1300x650

245(540)12.70/28.58

50(20)30

0~46-10~21R407C

Model No.Indoor unit

Outdoor unit

*The measurement static pressure of ARY60UU is 100Pa and ARY90TL is 196Pa.

ARY60UU

ARY90TL

Optional parts

Simple Remote Controller: UTY-RSNYMLong-Life Filter: UTD-LF60KA (For ARY60UU)

Remote Sensor Unit: UTY-XSZXExternal Control Set: UTD-ECS5A (For ARY60UU)

Design also corresponding to high static pressure

Model: ARY90TL

Wired R.C.

Wired R.C.

Low noise

Turbulent air flow is reduced by cutting off the corners of conventional indoor unit front panel and fan case

Heat exchanger

Plastic fan(ø225mm)

Casing(Plastic)

500mm

400m

m

(ARY60UU)

Plastic fan [45dB(A)] (ARY60UU)

Low noise is realized by adopting plastic case, plastic fan.

* Model : Material (At 100Pa : Actual noise measurement value)

MAX.

300pa

Top view Front view Side view

1,550

1,410

660

713

(MA

X)

700600

450

Front view Top viewSide view (L)

Side view (R)

Rear view

88400 1,080(Bolt pitch)

1,000862

8511,050 85

371356

208

41 123

139108

1

2

3

4

324 14

295

585

500(

Bol

t pitc

h)

71

Refrigerant piping flare connection (Liquid)

Refrigerant piping flare connection (Gas)Drain piping connection

2

1

3

Page 35: Fujitsu 2012 catalog

068

Control several indoor units with one outdoor unit.Build the optimum system you desire.

Multi type Line-up

2 & 3-4 Rooms Multi

8 Rooms Multi

Specifications of All Indoor Units

Multi Combination Table

Simultaneous Multi

Big Multi

Optional Parts for Split & Multi Split

070

072

074

078

080

090

092

094

Multi Split type Air ConditionersMultiple Rooms Comfor tably

If you want to keep a large floor as well as many rooms comfortable, we recommend you use Multi Split to build a simple system using one outdoor unit.Choose from a large lineup the air conditioner types that match your rooms.You can mix and match them at will.Build the system that is just right for you.

Page 36: Fujitsu 2012 catalog

071070

M u l t i S p l i t

Multi type Line-up

Connectable Indoor unit line-up

Indoor unit features

Multi Split Line-up

14

4 5 5.4

18 24

6.8

30

8

45

14

Capacity range

Model code

Cooling rated capacity(kW)

AOYG14LAC2 AOYG18LAC2

AOYG18LAT3 AOYG24LAT3

Branch box

Separation tube

Outdoor unit

Outdoor unit

Outdoor unit

AOYG30LAT4

AOYG45LAT8

Outdoor unit

(Branch Box)

BTU

Model name

Type

Capacity(kW) Heating

Cooling

Indoor Unit

Outdoor Unit

kW Class

7000

9000

12000

7000

9000

12000

14000

18000

24000

9000

12000

14000

7000

9000

12000

14000

18000

14000

18000

7000

9000

12000

14000

18000

2.0

2.5

3.5

2.0

2.5

3.5

4.0

5.0

7.0

2.5

3.5

4.0

2.0

2.5

3.5

4.0

5.0

4.0

5.0

2.0

2.5

3.5

4.0

5.0

3 Rooms2 Rooms

ASYG07/09/12LJ

ASYG18/24LF

AGYG09/12/14LV

AUYG07/09/12/14/18LV

ABYG14/18LV

ARYG07/09/12/14/18LL

AOYG14LAC2

4.0

4.4

AOYG18LAC2

5.0

5.6

AOYG18LAT3

5.4

6.8

AOYG24LAT3

6.8

8.0

AOYG30LAT4

4 Rooms

8.0

9.6

AOYG45LAT8

8 Rooms

14.0

16.0

●●●●●●�

●●�

●●●�

●●●�

●●●●●●●�

●●●●●●●�

●�

●●●●�

●●●●●●●●�

●●●●●●●●●●●●●●●

●●●●●●●●●●●●●●●●●●●●●●●●

●●●●●●●●●●●●●●●●●●●●●●●●

●●●●●●�

8 Rooms Multi Up to 8 units

4 Rooms Multi Up to 4 units

3 Rooms Multi Up to 3 units

2 Rooms Multi Up to 2 units

Note : 1. 2 Rooms Multi : Connectable indoor units are 2 units. AOYG14LAC2 : Total capacity of indoor units connected must be between 4.0kW and 6.2kW. AOYG18LAC2 : Total capacity of indoor units connected must be between 4.0kW and 7.0kW. 2. 3 Rooms Multi : Connectable indoor units are 2 to 3 units. AOYG18LAT3 : Total capacity of indoor units connected must be between 4.0kW and 8.5kW. AOYG24LAT3 : Total capacity of indoor units connected must be between 4.0kW and 10.5kW. 3. 4 Rooms Multi : Connectable indoor units are 3 to 4 units. AOYG30LAT4 : Total capacity of indoor units connected must be between 7.9kW and 14.4kW. 4. 8 Rooms Multi : Connectable indoor units are 2 to 8 units. AOYG45LAT8 : Total capacity of indoor units connected must be between 11.2kW and 18.2kW.

ASYG07/09/12LJASYG07/09/12/14LUASYG18/24LFAGYG09/12/14LVAUYG07/09/12/14/18LVABYG14/18LVARYG07/09/12/14/18LL

●●●●

●●●●●●●

●●●●●●●

●●●●●●●

●●●●●● ●

●●●●●●●

● ●●●●●●●

●●●●●●●

●●●●

●●●●

●●●

: Optional function

●●●●●●

ASYG07/09/12/14LU

Low noisePOWERFULPOWERFUL

Page 37: Fujitsu 2012 catalog

073072

2 & 3-4 Rooms Multi

3 ROOMS 4 ROOMS

AOYG18LAT3AOYG24LAT3

2 ROOMS

AOYG14LAC2AOYG18LAC2

CLASSA

ALLDC

CLASSA

ALLDC

CLASSA

ALLDC

AOYG30LAT4

Space-saving installation

Flexible installation

Multiple indoor units can be connected to 1 outdoor unit, and long piping connection is also possible. Compared with single type, the outdoor unit can be installed in various places to realize the space-saving installation.

Up to max. piping length 70m (AOYG30LAT4), max. height difference 15m can be supported. Multi type can be installed at large-size residence or multiple floors.

Wide range of indoor units with various models6 types, 20 models are lined up in the capacity range from 2kW to 7kW class.The wide-ranging needs can be met from the private room of residence or hotel to large shop.

Max.Piping Length (Each Unit):20m (AOYG14LAC2 / 18LAC2), 25m (AOYG18LAT3 / 24LAT3 / 30LAT4)

Max.Height:15m (AOYG14LAC2 / 18LAC2 / 18LAT3 / 24LAT3/30LAT4)

2 ROOMSModel: AOYG14LAC2 / AOYG18LAC2

4 ROOMS Models: AOYG30LAT4

3 ROOMS Models: AOYG18LAT3 / AOYG24LAT3

Top view

Front viewSide viewBottom view

900

650

2183

0

9

40 31 12330

400

41

12

94

57 114

(493

)11

4 x

3 =3

42

5

370

Top view

Front view

Bottom view

Side view

900

21

700

9

40

650

370

31 12330

400

41

12 94

57 114

228

Top view

540

Front view

Bottom view

Side view

288

352

19107279020

541

57

318

114

87

20

9

Air Flow

SPECIFICATIONS (2 ROOMS, 3 ROOMS, 4 ROOMS)

* Connect to connection valve by the adapter.

Power Source

OperationRangeRefrigerant

Net Dimension H x W x DWeight

Piping Connections

Max. length

Max. Height Difference

CoolingHeatingCoolingHeating

CoolingHeating

mmkg(lbs)

mm

m

°CDB

V/Ø/Hz

Outdoor unitModel No.

Between Outdoor Unit and Each Indoor Units.Between Indoor Units.

AOYG14LAC2

230/1/504.0(1.4~4.4)4.4(1.1~5.4)

4749

540x790x29037(82)

Ø6.35x2

Ø9.52x2

15

1010~46-15~24R410A

30 / 20

15

10

AOYG18LAT3

230/1/505.4(1.8~6.8)6.8(2.0~7.7)

4647

700x900x33055(121)

Ø6.35x3

Ø9.52x2, Ø12.7 *(Ø9.52x3)

-10~46-15~24R410A

50 / 25

AOYG24LAT3

230/1/506.8(1.8~7.8)8.0(2.0~8.0)

4849

700x900x33055(121)

Ø6.35x3

Ø9.52x2, Ø12.7 *(Ø9.52x3)

15

10-10~46-15~24R410A

50 / 25

AOYG30LAT4

230/1/508.0(3.5~10.0)9.6(3.7~11.3)

5051

830x900x33068(150)Ø6.35x4

(*Ø6.35x3, Ø9.52)

Ø9.52x2, Ø12.7x2 *(Ø9.52x3, Ø12.7)

*(Ø9.52x2, Ø12.7, Ø15.88)

15

100~46

-10~24R410A

70 / 25

AOYG18LAC2

230/1/505.0(1.7~5.6)5.6(1.8~6.1)

5051

540x790x29038(84)

Ø6.35x2

Ø9.52x2 *(Ø9.52, Ø12.7)

15

30 / 20

1010~46-15~24R410A

Small (Liquid)

Large (Gas)

Con

nect

ion

pipe

Total / Each

Noise

Rated Capacity(min-max)

dB(A)

kW

Total Piping Length:30m (AOYG14LAC2 / 18LAC2), 50m (AOYG18LAT3 / 24LAT3), 70m (AOYG30LAT4)

Ex.) Single type installation

3 outdoor units 1 outdoor unit

Multi type installation

Page 38: Fujitsu 2012 catalog

075074

8 Rooms Multi

AOYG45LAT8

ALLDC

High Efficiency & Compact

Innovated technologyCompact outdoor unit

Central Remote Controller

More Comfort

Every room meet set point most quickly and comfortably by optimized refrigerant control.

Quick comfort by optimized refrigerant control

•Suitable for large homes, shops, small buildings, and a variety of other multi installations

•Up to 8 indoor units can be connected•Excellent installability, lightweight, compact yet high efficiency operation outdoor unit

High efficiency DC twin rotary compressor : A high performance, low noise, large capacity DC twin rotary compressor is used.

Heat exchanger : Reduced compact size and energy saving has been realized by utilizing high density piping design and 3-Row heat exchanger.

High efficiency large fan : New high efficiency fan is mounted.

DC fan motor : High performance and high efficiency has been realized by using a small DC fan motor.

1290mm

914mm

About 14kW class multi split model

New modelHeight difference

29%

Refrigerant control by branch box

Meet set point

Increasecapacity

Decreasecapacity

Increasecapacity

Decreasecapacity

Meet set point

All operation start

The actual performance is conducted under various outside temperatures depending on weather and seasons, furthermore, especially for multi system, not all the rooms are operated all the time. So over 90% of actual operation time, air conditioners are operated at partial capacity instead of rated capacity.Considering these, we focused on energy-saving performance which is based on actual use.Efficiency of part load performance was drastically improved by developing ALL DC and our own inverter system.

High seasonal efficiency

(50% load)EER4.75EER

frequency operation range

5

3

1

0

Part load(%)25 50 75 100 %

4.75

Central remote controller developed for residential applications.All indoor units can be batched controlled using simple operations. Schedule management and other functions can be used to achieve even greater energy savings.

UTY-DMMYM

Central & Individual ControlBatched control of up to 8 indoor units. The temperature, airflow volume, and remote control prohibition settings of all indoor units can be batched.

User-friendly operation• Large backlight LED screen• Large easy-to-see operation panel

Corresponds to 9 different languages (English, German, French, Spanish, Russian, Portuguese, Italian, Greek, and Turkish)

Multiple language support

UTY-DMMYM

Power & Transmission line

Outdoor unit

Indoor unit

R.C.

Branch box

Remote controller cable

Controllable

1multi systemMax. Controllable

8 indoor units

System configuration

Setting the address is not required* When the indoor units are connected to a branch box, the addresses for each indoor unit are set automatically.

*Note : Cross-over connections are not allowed in the refrigerant system. Group settings are not allowed.

Transmission line

10ºC heat operation

Prohibited Settings

The remote controller operation of all indoor units comes with a lock function to prevent unapproved operations in the various rooms. The central remote controller also has a key lock function to prevent children from playing with it, etc

When you leave, minimum heating operation is performed to maintain the room temperature (maintain at 10ºC).

Economy operation

Economy operation is energy saving, as the set temperature of indoor unit is shifted by 1°C and the maximum electric value of the outdoor unit is suppressed.

Tem

p.

Economy operation

Shift setting temp

Normal operation

Time

Set temperature

10°C

20°C

10ºC heatbutton

Indoor unit operation

ON

START

Low noise operation

Users can choose from 4 low noise levels, depending on the installation environment. The operation time can be set using the timer.

Air conditioning load factor

Capacity

Operating sound

time

100%

58dB

0

0

Heat load

down

Quiet priority low noise mode

Quiet priority setting

Weekly schedule timer

The ON/OFF setting can be set for 4 times a day. Two weekly patterns can be set to match the cooling and heating seasons.

Monday~Friday Saturday~Sunday

7Time

Time

12 17 23

Summerseasonpattern

Winterseasonpattern

Cool Cool Cool

8 1 18 22

Cool Cool Cool

7 1213 23

Heat

Heat

Heat

7 1 18 23

Heat Heat Heat

Option

Page 39: Fujitsu 2012 catalog

077076

8 Rooms Multi

Flexible Design & Easy Installation

Large capacity connectionUp to 8 indoor units can be connected to one outdoor unit. A maximum of 130% indoor unit connectable capacity. Match any room layout

Connectableindoor unit number

Up to 8

Total pipe length

115m max.

Connectableindoor unit capacity

Ratio up to 130%

Branch box

Separation tubeOutdoor unit

Can be installed in high rise condominium or commercial building

Actual pipe length70m max.

Height difference betweenO.U. and I.U.30m max.

Height differencebetween I.U. and I.U.

15m max.

Pipe length betweenI.U. and Branch box

15m max.

Long piping design

Indoor unit

Branch boxSeparation tube

All flare piping connection and simple installation that minimizes wiring mistakes.

Power & Transmission lineTransmission line

Outdoor unit

Powersource

Power supply

Piping

Wiring mistake automatic check functionThe check operation detects wiring mistakes in advance.

Simple wiring connection that is not cross connectionWiring connection is the same as single split or multi type.

Branch box

Simple all flare piping connection

Branch Box can be mounted flexibly.Allowed Branch Box Mounting Direction

HorizontalWall Mounting

VerticalWall Mounting

Install the unit with its top side facing upwards.

Install the unit with the control box facing upwards.

Hanging from the ceiling

Do not hang from the ceiling when performing a vertical installation.

DimensionsOutdoor UnitAOYG45LAT8

Branch BoxUTP-PY03A(3 branches type)

Branch BoxUTP-PY02A(2 branches type)

(Unit : mm)650

970 24 370 12

166

370

24

401

440

914

21

24

Specifications

m3/h

kW

kW

mm

kg(Ibs)

mm

m

°CDB

dB(A)

kW

Rated Capacity

Input Power

Power source V/ Ø/Hz

Cooling

Heating

Cooling

Heating

Cooling

Heating

Cooling

Heating

CoolingIndoor unit connectable capacity

Air flow rate

Net Dimensions H x W x DWeight

Piping Connections (Small / Large)

Max Pipe Length

Max Height Difference (O.U ~ I.U)

Operating range

Refrigerant

Sound pressure level

Heat exchanger fin

Cooling

Heating

AOYG45LAT8

8

11.2 - 18.2

230/1/50

14.0

16.0

5.20

5.07

4,650

4,800

56

58

Plate fin coil

914 x970x370

98 (217)

9.52/15.88

115 (Total)

30

-5 to 46

-15 to 24

R410A

Model name

Maximum Connectable Indoor Unit

UTP-PY03A

1 to 3 Units

1Ø 230V ~50Hz

198-264V

10

0.05

195x433x370

9

Main: 9.52x1, Branch:6.35x3

Main: 15.88x1, Branch:12.7x3

Flare

UTP-PY02A

1 to 2 Units

1Ø 230V ~50Hz

198-264V

10

0.05

195x433x370

9

Main: 9.52x1, Branch:6.35x2

Main: 15.88x1, Branch:12.7x2

Flare

Model name

Connectable indoor unit

Power source

Available voltage range

Powwer consumption

Running currrent

Dimensions (HxWxD)

Weight

W

A

mm

kgLiquid

GasConnectionpipe

Note: Specifications are based on the following conditions.Power source of specifications: 230V.

Size mm

Method

214

469

469

432

433 75

1958568

95

256 37

214

825

7570

959557

24

174154

110

134

216256

176469

469

432

433 75

1958568

95 372

148

25

7570

95

152

24

174154

110

134

216176

Page 40: Fujitsu 2012 catalog

079078

Specifications of All Indoor Units

kW Class Power Source

Net DimensionWeightPipe Size

Noise

Air Flow

H/M/L/Q

H/M/L/Q

dB(A)

m3/h

Cooling

Heating

CoolingHeating

Liquid/Gas

kWV/Ø/Hz

mmkg(lbs)

mm

ABYG14LV

4.0230/1/50

36/34/33/29(Under ceiling)39/37/36/32(Floor console)36/34/33/29(Under ceiling)39/37/36/32(Floor console)

640/590/540/480640/590/540/480

199x990x65527(60)

Ø6.35/Ø12.7

ABYG18LV

5.0230/1/50

41/38/34/32(Under ceiling)44/41/37/35(Floor console)41/38/34/32(Under ceiling)44/41/37/35(Floor console)

780/700/560/500780/700/560/500

199x990x65527(60)

Ø6.35/Ø12.7

Indoor unitModel No.

kW Class Power Source

Net DimensionWeightPanel Pipe Size

Noise

Air Flow

H/M/L/Q

H/M/L/Q

dB(A)

m3/h

CoolingHeatingCoolingHeating

Liquid/Gas

kWV/Ø/Hz

mmkg(lbs)

mm

AUYG07LV

2.0230/1/50

33/31/29/2734/32/29/27

540/490/440/390540/490/440/390

245x570x57015(33.1)

Ø6.35/Ø9.52

AUYG09LV

2.5230/1/50

33/31/29/2734/32/29/27

540/490/440/390540/490/440/390

245x570x57015(33.1)

Ø6.35/Ø9.52

AUYG14LV

4.0230/1/50

40/35/32/2940/37/34/29

680/580/490/410700/620/550/430

245x570x57015(33.1)

Ø6.35/Ø12.7

AUYG12LV

3.5230/1/50

37/33/31/2837/33/31/28

610/530/470/410610/530/470/410

245x570x57015(33.1)

UTG-UFYD-WØ6.35/Ø9.52

AUYG18LV

5.0230/1/50

42/37/33/2944/40/37/30

750/610/520/410800/710/600/450

245x570x57015(33.1)

Ø6.35/Ø12.7

Indoor unitModel No.

kW Class Power Source

Net DimensionWeightPipe SizeExternal static pressureDrain pump

Noise

Air Flow

H/M/L/Q

H/M/L/Q

dB(A)

m3/h

CoolingHeatingCoolingHeating

Liquid/Gas

kWV/Ø/Hz

mmkg(lbs)

mm

ARYG07LL

2.0230/1/50

28/26/25/2428/26/25/24

550/490/470/440550/490/470/440

198x700x62017(37.5)

Ø6.35/Ø9.52

ARYG09LL

2.5230/1/50

28/27/26/2528/26/25/24

600/550/500/450600/550/500/450

198x700x62019(41.8)

Ø6.35/Ø9.52

ARYG14LL

4.0230/1/50

32/30/28/2633/30/28/25

800/700/600/480800/700/600/480

198x700x62019(41.8)

Ø6.35/Ø12.7

ARYG12LL

3.5230/1/50

29/28/27/2629/28/27/24

650/600/550/480650/600/550/480

198x700x62019(41.8)

Ø6.35/Ø9.520 to 90

Standard

ARYG18LL

5.0230/1/50

32/31/30/2933/32/31/29

940/880/820/750940/880/820/750

198x900x62023(50.6)

Ø6.35/Ø12.7

Indoor unitModel No.

kW Class Power Source

Net DimensionWeightPipe Size

Noise

Air Flow

H/M/L/Q

H/M/L/Q

dB(A)

m3/h

CoolingHeatingCoolingHeating

Liquid/Gas

kWV/Ø/Hz

mmkg(lbs)

mm

ASYG07LU

2.0230/1/50

35/30/28/2135/30/28/21

570/520/470/330570/520/470/330

282x870x1859.5(21)

Ø6.35/Ø9.52

ASYG09LU

2.5230/1/50

36/32/28/2136/32/28/21

600/550/470/330600/550/470/330

282x870x1859.5(21)

Ø6.35/Ø9.52

ASYG12LU

3.5230/1/50

37/34/31/2137/34/31/21

660/600/530/330660/600/530/330

282x870x1859.5(21)

Ø6.35/Ø9.52

ASYG14LU

4.0230/1/50

41/36/33/2541/36/34/27

710/640/570/390710/640/590/430

282x870x1859.5(21)

Ø6.35/Ø12.7

Indoor unitModel No.

kW Class Power Source

Net DimensionWeightPipe Size

Noise

Air Flow

H/M/L/Q

H/M/L/Q

dB(A)

m3/h

Cooling

Heating

CoolingHeating

Liquid/Gas

kWV/Ø/Hz

mmkg(lbs)

mm

Indoor unitModel No.

kW Class Power Source

Net DimensionWeightPipe Size

Noise

Air Flow

H/M/L/Q

H/M/L/Q

dB(A)

m3/h

CoolingHeatingCoolingHeating

Liquid/Gas

kWV/Ø/Hz

mmkg(lbs)

mm

ASYG07LJ

2.0230/1/50

36/32/29/2136/32/29/22

560/500/430/310560/500/430/330

280x790x2038(17.6)

Ø6.35/Ø9.52

ASYG09LJ

2.5230/1/50

37/33/29/2137/33/29/22

600/520/430/310600/520/430/330

280x790x2038(17.6)

Ø6.35/Ø9.52

ASYG18LF

5.0230/1/50

43/37/33/2642/37/33/25

900/740/620/550900/740/620/550

320x998x23814(30.8)

Ø6.35/Ø12.7

ASYG12LJ

3.5230/1/50

40/36/30/2140/36/31/22

660/560/450/310660/560/470/330

280x790x2038(17.6)

Ø6.35/Ø9.52

ASYG24LF

7.0230/1/50

49/42/37/3348/42/37/33

1120/900/740/6201100/900/740/620

320×998×23814(30.8)

Ø6.35/Ø15.88

Indoor unitModel No.

AGYG09LV

2.5230/1/50

39/34/28/22

39/35/30/22

530/440/360/270 530/460/380/270

600x740x20014(30.7)

Ø6.35/Ø9.52

AGYG12LV

3.5230/1/50

42/36/30/22

42/38/32/22

600/490/380/270600/510/410/270

600x740x20014(30.7)

Ø6.35/Ø9.52

AGYG14LV

4.0230/1/50

44/38/31/22

44/39/33/22

650/520/400/270650/540/430/270

600x740x20014(30.7)

Ø6.35/Ø12.7

Compact wall mounted Floor ceiling

Compact cassette Wall mounted

Floor Slim duct

Page 41: Fujitsu 2012 catalog

081080

Multi Combination Table

791277799

---79

129

12

1Room

2Room

COOLING OPERATIONCooling Capacity

Room 1KW

Room 2KW

Total Capacity (min-max)KW

EER Energy efficiency class

KW

Input Power (min-max)AOYG14LAC2

2.10 2.50 3.50 2.00 1.95 1.65 2.00 1.70

---

2.00 2.05 2.35 2.00 2.30

2.10 ( 1.2 - 2.7 )2.50 ( 1.2 - 3.2 )3.50 ( 1.2 - 3.7 )4.00 ( 1.4 - 4.4 )4.00 ( 1.4 - 4.4 )4.00 ( 1.4 - 4.6 )4.00 ( 1.4 - 4.5 )4.00 ( 1.4 - 4.7 )

0.59 ( 0.30 - 0.76 )0.65 ( 0.30 - 1.03 )1.04 ( 0.30 - 1.21 )1.09 ( 0.35 - 1.40 )1.09 ( 0.35 - 1.40 )1.05 ( 0.35 - 1.47 )1.09 ( 0.35 - 1.43 )1.05 ( 0.35 - 1.47 )

3.56 3.85 3.37 3.67 3.67 3.81 3.67 3.81

AAAAAAAA

Combination of indoor unit

79127779912

---79

129

1212

2.10 2.50 3.50 2.10 2.10 1.90 2.50 2.10 2.50

---

2.10 2.50 3.10 2.50 2.90 2.50

2.10 ( 1.4 - 2.7 )2.50 ( 1.4 - 3.2 )3.50 ( 1.4 - 3.7 )4.20 ( 1.7 - 5.2 )4.60 ( 1.7 - 5.3 )5.00 ( 1.7 - 5.6 )5.00 ( 1.7 - 5.6 )5.00 ( 1.7 - 5.7 )5.00 ( 1.7 - 5.8 )

0.48 ( 0.30 - 0.72 )0.64 ( 0.30 - 1.05 )1.02 ( 0.30 - 1.34 )1.24 ( 0.35 - 1.68 )1.26 ( 0.35 - 1.79 )1.55 ( 0.35 - 1.95 )1.56 ( 0.35 - 1.95 )1.55 ( 0.35 - 1.95 )1.56 ( 0.35 - 1.99 )

4.38 3.94 3.43 3.39 3.65 3.23 3.21 3.23 3.21

AAAAAAAAA

1Room

2Room

COOLING OPERATIONCooling Capacity

Room 1KW

Room 2KW

Total Capacity (min-max)KW

EER Energy efficiency class

KW

Input Power (min-max)AOYG18LAC2 Combination of indoor unit

79121479121491214121479121491214912

----77779991212777799999

-------------777777799

2.30 2.70 3.50 4.20 2.30 2.70 3.02 3.42 2.50 2.82 3.23 2.55 2.89 1.80 2.00 2.33 2.58 1.89 2.22 2.47 1.80 2.12

----

2.30 2.30 1.98 1.88 2.50 2.18 2.07 2.55 2.41 1.80 1.70 1.53 1.41 1.89 1.72 1.58 1.80 1.64

-------------

1.80 1.70 1.53 1.41 1.61 1.46 1.35 1.80 1.64

2.30 ( 1.5 - 2.7 )2.70 ( 1.5 - 3.3 )3.50 ( 1.5 - 3.7 )4.20 ( 1.5 - 4.8 )4.60 ( 1.8 - 5.0 )5.00 ( 1.8 - 5.7 )5.00 ( 1.8 - 6.1 )5.30 ( 1.8 - 6.6 )5.00 ( 1.8 - 6.2 )5.00 ( 1.8 - 6.3 )5.30 ( 1.8 - 6.7 )5.10 ( 1.8 - 6.3 )5.30 ( 1.8 - 6.7 )5.40 ( 1.8 - 6.8 )5.40 ( 1.8 - 6.8 )5.40 ( 1.8 - 6.8 )5.40 ( 2.0 - 6.8 )5.40 ( 1.8 - 6.8 )5.40 ( 1.8 - 6.8 )5.40 ( 2.0 - 6.8 )5.40 ( 1.8 - 6.8 )5.40 ( 1.8 - 6.8 )

0.65 ( 0.45 - 0.75 )0.80 ( 0.45 - 1.09 )1.09 ( 0.45 - 1.15 )1.16 ( 0.45 - 1.41 )1.22 ( 0.50 - 1.43 )1.35 ( 0.50 - 1.81 )1.34 ( 0.50 - 2.06 )1.34 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )1.34 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.60 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.60 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )

3.54 3.38 3.21 3.62 3.77 3.70 3.73 3.96 3.70 3.70 3.93 3.78 3.93 4.03 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00

AAAAAAAAAAAAAAAAAAAAAA

1Room

2Room

3Room

COOLING OPERATIONCooling Capacity

Room 1KW

Room 2KW

Room 3KW

Total Capacity (min-max)KW

EER Energy efficiency class

KW

Input Power (min-max)AOYG18LAT3 Combination of indoor unit

79121418791214189121418121418791214189121418121491214

18*1

121412

-----77777999912121277777999912129999121212

-----------------77777777777999999

12

2.30 2.70 3.50 4.20 5.00 2.30 2.70 3.42 4.13 4.52 2.75 3.41 3.94 4.35 3.15 3.67 4.04 2.27 2.52 2.84 3.16 3.54 2.38 2.70 3.02 3.40 2.52 2.83 2.27 2.58 2.89 3.27 2.41 2.72 2.27

-----

2.30 2.30 2.38 2.37 2.08 2.75 2.79 2.66 2.35 3.15 3.03 2.66 2.27 2.14 1.98 1.82 1.63 2.38 2.21 2.04 1.84 2.52 2.34 2.27 2.11 1.95 1.77 2.41 2.24 2.27

-----------------

2.27 2.14 1.98 1.82 1.63 2.03 1.88 1.74 1.56 1.76 1.63 2.27 2.11 1.95 1.77 1.97 1.84 2.27

2.30 ( 1.5 - 2.7 )2.70 ( 1.5 - 3.3 )3.50 ( 1.5 - 3.7 )4.20 ( 1.5 - 4.8 )5.00 ( 1.8 - 5.6 )4.60 ( 1.8 - 5.0 )5.00 ( 1.8 - 5.7 )5.80 ( 1.8 - 6.1 )6.50 ( 1.8 - 7.2 )6.60 ( 1.8 - 7.8 )5.50 ( 1.8 - 6.2 )6.20 ( 1.8 - 6.8 )6.60 ( 1.8 - 7.7 )6.70 ( 1.8 - 7.9 )6.30 ( 1.8 - 7.2 )6.70 ( 1.8 - 7.8 )6.70 ( 1.8 - 7.9 )6.80 ( 1.8 - 7.4 )6.80 ( 1.8 - 7.8 )6.80 ( 1.8 - 8.1 )6.80 ( 2.0 - 8.4 )6.80 ( 2.0 - 8.5 )6.80 ( 1.8 - 8.2 )6.80 ( 1.8 - 8.2 )6.80 ( 2.0 - 8.4 )6.80 ( 2.0 - 8.5 )6.80 ( 1.8 - 8.2 )6.80 ( 2.0 - 8.5 )6.80 ( 1.8 - 8.2 )6.80 ( 1.8 - 8.3 )6.80 ( 2.0 - 8.5 )6.80 ( 2.0 - 8.5 )6.80 ( 1.8 - 8.3 )6.80 ( 2.0 - 8.5 )6.80 ( 1.8 - 8.3 )

0.65 ( 0.45 - 0.75 )0.80 ( 0.45 - 1.09 )1.09 ( 0.45 - 1.15 )1.16 ( 0.45 - 1.41 )1.50 ( 0.50 - 1.96 )1.20 ( 0.50 - 1.40 )1.36 ( 0.50 - 1.78 )1.70 ( 0.50 - 1.97 )1.91 ( 0.50 - 2.46 )1.91 ( 0.50 - 2.87 )1.55 ( 0.50 - 2.02 )1.90 ( 0.50 - 2.45 )1.91 ( 0.50 - 2.77 )1.91 ( 0.50 - 2.87 )1.90 ( 0.50 - 2.74 )1.91 ( 0.50 - 2.87 )1.92 ( 0.50 - 2.87 )1.92 ( 0.50 - 2.37 )1.93 ( 0.50 - 2.60 )1.93 ( 0.50 - 2.87 )1.94 ( 0.60 - 2.87 )1.94 ( 0.60 - 2.87 )1.93 ( 0.50 - 2.87 )1.93 ( 0.50 - 2.87 )1.94 ( 0.60 - 2.87 )1.94 ( 0.60 - 2.87 )1.94 ( 0.50 - 2.87 )1.94 ( 0.60 - 2.87 )1.94 ( 0.50 - 2.87 )1.94 ( 0.50 - 2.87 )1.94 ( 0.60 - 2.87 )1.94 ( 0.60 - 2.87 )1.94 ( 0.50 - 2.87 )1.94 ( 0.60 - 2.87 )1.94 ( 0.50 - 2.87 )

3.54 3.38 3.21 3.62 3.33 3.83 3.68 3.41 3.40 3.46 3.55 3.26 3.46 3.51 3.32 3.51 3.49 3.54 3.52 3.52 3.51 3.51 3.52 3.52 3.51 3.51 3.51 3.51 3.51 3.51 3.51 3.51 3.51 3.51 3.51

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

1Room

2Room

3Room

COOLING OPERATIONCooling Capacity

Room 1KW

Room 2KW

Room 3KW

Total (min-max)KW

EER Energy efficiency class

KW

Input Power (min-max)AOYG24LAT3 Combination of indoor unit

1Room

2Room

HEATING OPERATIONHeating Capacity

Room 1KW

Room 2KW

Total Capacity (min-max)KW

COP Energy efficiency class

KW

Input Power (min-max)AOYG14LAC2

79

1277799

---79

129

12

2.70 ( 0.9 - 3.3 )3.30 ( 0.9 - 4.2 )4.00 ( 0.9 - 4.8 )4.40 ( 1.1 - 5.4 )4.40 ( 1.1 - 5.4 )4.40 ( 1.1 - 5.5 )4.40 ( 1.1 - 5.4 )4.40 ( 1.1 - 5.5 )

0.64 ( 0.25 - 0.89 )0.87 ( 0.25 - 1.37 )1.13 ( 0.25 - 1.59 )1.03 ( 0.25 - 1.78 )1.03 ( 0.25 - 1.78 )1.02 ( 0.25 - 1.76 )1.03 ( 0.25 - 1.78 )1.02 ( 0.25 - 1.76 )

4.22 3.79 3.54 4.27 4.27 4.31 4.27 4.31

AAAAAAAA

2.70 3.30 4.00 2.20 2.15 1.95 2.20 2.00

---

2.20 2.25 2.45 2.20 2.40

Combination of indoor unit

1Room

2Room

HEATING OPERATIONHeating Capacity

Room 1KW

Room 2KW

Total Capacity (min-max)KW

COP Energy efficiency class

KW

Input Power (min-max)AOYG18LAC2

2.70 ( 1.4 - 3.3 )3.30 ( 1.4 - 4.2 )4.00 ( 1.4 - 4.8 )5.40 ( 1.8 - 6.0 )5.50 ( 1.8 - 6.0 )5.60 ( 1.8 - 6.1 )5.60 ( 1.8 - 6.1 )5.60 ( 1.8 - 6.2 )5.60 ( 1.8 - 6.3 )

0.64 ( 0.40 - 1.07 )0.92 ( 0.40 - 1.47 )1.14 ( 0.40 - 1.70 )1.24 ( 0.50 - 1.61 )1.36 ( 0.50 - 1.87 )1.38 ( 0.50 - 1.88 )1.41 ( 0.50 - 1.90 )1.38 ( 0.50 - 1.88 )1.34 ( 0.50 - 1.84 )

4.22 3.61 3.51 4.37 4.04 4.06 3.97 4.07 4.18

AABAAAAAA

2.70 3.30 4.00 2.70 2.50 2.30 2.80 2.45 2.80

---

2.70 3.00 3.30 2.80 3.15 2.80

Combination of indoor unit

79

1277799

12

---79

129

1212

1Room

2Room

3Room

HEATING OPERATIONHeating Capacity

Room 1KW

Room 2KW

Room 3KW

Total Capacity (min-max)KW

COP Energy efficiency class

KW

Input Power (min-max)AOYG18LAT3

2.70 3.30 3.80 4.80 2.70 3.25 3.71 4.29 3.15 3.51 4.03 3.20 3.71 2.23 2.52 2.83 3.14 2.39 2.69 2.99 2.27 2.57

----

2.70 2.75 2.59 2.51 3.15 2.89 2.77 3.20 3.09 2.23 2.14 1.98 1.83 2.39 2.22 2.06 2.27 2.12

-------------

2.23 2.14 1.98 1.83 2.03 1.89 1.75 2.27 2.12

2.70 ( 1.5 - 3.3 )3.30 ( 1.5 - 4.2 )3.80 ( 1.5 - 4.8 )4.80 ( 1.5 - 5.8 )5.40 ( 2.0 - 6.1 )6.00 ( 2.0 - 6.4 )6.30 ( 2.0 - 6.5 )6.80 ( 2.0 - 7.1 )6.30 ( 2.0 - 6.5 )6.40 ( 2.0 - 6.6 )6.80 ( 2.0 - 7.2 )6.40 ( 2.0 - 6.6 )6.80 ( 2.0 - 7.3 )6.70 ( 2.0 - 7.7 )6.80 ( 2.0 - 7.8 )6.80 ( 2.0 - 7.8 )6.80 ( 2.0 - 8.0 )6.80 ( 2.0 - 7.8 )6.80 ( 2.0 - 7.9 )6.80 ( 2.0 - 8.0 )6.80 ( 2.0 - 7.9 )6.80 ( 2.0 - 7.9 )

0.83 ( 0.43 - 1.00 )1.00 ( 0.42 - 1.30 )1.26 ( 0.42 - 1.62 )1.30 ( 0.42 - 1.70 )1.59 ( 0.52 - 1.93 )1.87 ( 0.52 - 2.06 )1.98 ( 0.52 - 2.06 )1.92 ( 0.50 - 2.06 )1.98 ( 0.52 - 2.06 )1.99 ( 0.52 - 2.06 )1.91 ( 0.50 - 2.06 )1.98 ( 0.52 - 2.06 )1.90 ( 0.50 - 2.06 )1.70 ( 0.50 - 2.06 )1.70 ( 0.50 - 2.06 )1.69 ( 0.50 - 2.06 )1.62 ( 0.50 - 2.06 )1.69 ( 0.50 - 2.06 )1.68 ( 0.50 - 2.06 )1.62 ( 0.50 - 2.06 )1.68 ( 0.50 - 2.06 )1.67 ( 0.50 - 2.06 )

3.25 3.30 3.02 3.69 3.40 3.21 3.18 3.54 3.18 3.22 3.56 3.23 3.58 3.94 4.00 4.02 4.20 4.02 4.05 4.20 4.05 4.07

CCDBBCDBDCBCBAAAAAAAAA

Combination of indoor unit

79

121479

12149

1214121479

12149

12149

12

----7777999

1212777799999

-------------777777799

1Room

2Room

3Room

HEATING OPERATIONHeating Capacity

Room 1KW

Room 2KW

Room 3KW

Total Capacity (min-max)KW

COP Energy efficiency class

KW

Input Power (min-max)AOYG24LAT3

2.70 3.30 3.80 4.80 6.00 2.75 3.30 4.12 4.80 5.39 3.30 4.00 4.68 5.16 3.80 4.31 4.80 2.47 2.86 3.25 3.65 4.09 2.74 3.09 3.52 3.97 2.93 3.31 2.63 2.98 3.37 3.81 2.83 3.17 2.67

-----

2.75 2.80 2.88 2.80 2.51 3.30 3.30 3.22 2.84 3.80 3.59 3.20 2.47 2.42 2.28 2.13 1.91 2.74 2.55 2.42 2.18 2.93 2.76 2.63 2.46 2.32 2.10 2.83 2.64 2.67

-----------------

2.47 2.42 2.28 2.13 1.91 2.32 2.16 2.06 1.85 2.05 1.93 2.63 2.46 2.32 2.10 2.34 2.18 2.67

2.70 ( 1.5 - 3.3 )3.30 ( 1.5 - 4.2 )3.80 ( 1.5 - 4.8 )4.80 ( 1.5 - 5.8 )6.00 ( 1.6 - 7.1 )5.50 ( 2.0 - 6.1 )6.10 ( 2.0 - 7.0 )7.00 ( 2.0 - 7.3 )7.60 ( 2.0 - 8.3 )7.90 ( 2.0 - 8.3 )6.60 ( 2.0 - 7.4 )7.30 ( 2.0 - 7.7 )7.90 ( 2.0 - 8.3 )8.00 ( 2.0 - 8.5 )7.60 ( 2.0 - 7.8 )7.90 ( 2.0 - 8.4 )8.00 ( 2.0 - 8.6 )7.40 ( 2.0 - 8.6 )7.70 ( 2.0 - 8.8 )7.80 ( 2.0 - 8.9 )7.90 ( 2.0 - 9.2 )7.90 ( 2.0 - 9.2 )7.80 ( 2.0 - 9.0 )7.80 ( 2.0 - 9.1 )8.00 ( 2.0 - 9.2 )8.00 ( 2.0 - 9.2 )7.90 ( 2.0 - 9.1 )8.00 ( 2.0 - 9.2 )7.90 ( 2.0 - 9.1 )7.90 ( 2.0 - 9.2 )8.00 ( 2.0 - 9.2 )8.00 ( 2.0 - 9.2 )8.00 ( 2.0 - 9.2 )8.00 ( 2.0 - 9.2 )8.00 ( 2.0 - 9.2 )

0.83 ( 0.43 - 1.00 )1.00 ( 0.42 - 1.30 )1.26 ( 0.42 - 1.62 )1.30 ( 0.42 - 1.70 )1.85 ( 0.42 - 2.40 )1.55 ( 0.52 - 1.93 )1.82 ( 0.52 - 2.52 )2.31 ( 0.52 - 2.66 )2.28 ( 0.50 - 2.87 )2.34 ( 0.50 - 2.87 )2.04 ( 0.52 - 2.68 )2.43 ( 0.52 - 2.87 )2.38 ( 0.50 - 2.87 )2.32 ( 0.50 - 2.87 )2.54 ( 0.52 - 2.87 )2.37 ( 0.50 - 2.87 )2.31 ( 0.50 - 2.87 )2.05 ( 0.50 - 2.68 )2.11 ( 0.50 - 2.87 )2.10 ( 0.50 - 2.80 )2.02 ( 0.50 - 2.72 )2.00 ( 0.50 - 2.70 )2.10 ( 0.50 - 2.87 )2.09 ( 0.50 - 2.87 )2.02 ( 0.50 - 2.72 )2.00 ( 0.50 - 2.69 )2.08 ( 0.50 - 2.87 )2.01 ( 0.50 - 2.70 )2.09 ( 0.50 - 2.87 )2.08 ( 0.50 - 2.87 )2.00 ( 0.50 - 2.70 )1.98 ( 0.50 - 2.68 )2.07 ( 0.50 - 2.80 )2.00 ( 0.50 - 2.69 )2.06 ( 0.50 - 2.78 )

3.25 3.30 3.02 3.69 3.24 3.55 3.35 3.03 3.33 3.38 3.24 3.00 3.32 3.45 2.99 3.33 3.46 3.61 3.65 3.71 3.91 3.95 3.71 3.73 3.96 4.00 3.80 3.98 3.78 3.80 4.00 4.04 3.86 4.00 3.88

CCDBBBCDCCCDCBDCBAAAAAAAAAAAAAAAAAA

Combination of indoor unit

79

12141879

1214189

12141812141879

1214189

12141812149

1214

18*1

121412

-----777779999

121212777779999

12129999

121212

-----------------77777777777999999

12

2 Rooms Multi cooling 2 Rooms Multi heating

3 Rooms Multi cooling 3 Rooms Multi heating

Note: •7:7000Btu/h / 9:9000Btu/h / 12:12000Btu/h models •Operating data under running indoor units are shown on the above table. •2 or more indoor units should be connected. •Cooling capacity is based on 27ºCDB/19ºCWB (indoor temperature), 35ºCDB (outdoor temperature). •Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) •The Total ability of connected a indoor unit is up to 24000Btu from 14000Btu.

Note: •7:7000Btu/h / 9:9000Btu/h / 12:12000Btu/h models •Operating data under running indoor units are shown on the above table. •2 or more indoor units should be connected. •Heating capacity is based on 20ºCDB (indoor temperature), 7ºCDB/6ºCWB (outdoor temperature). •Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) •The Total ability of connected a indoor unit is up to 24000Btu from 14000Btu.

Note: •7:7000Btu/h / 9:9000Btu/h / 12:12000Btu/h / 14:14000Btu/h / 18:18000Btu/h models •Operating data under running indoor units are shown on the above table. •2 or more indoor units should be connected. •Cooling capacity is based on 27ºCDB/19ºCWB (indoor temperature), 35ºCDB (outdoor temperature). •Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) •The Total ability of connected a indoor unit is up to 36000Btu from 14000Btu. *1: When ASYG18L is connected, connect at least 1 wall mounted type for 9000Btu.

Note: •7:7000Btu/h / 9:9000Btu/h / 12:12000Btu/h / 14:14000Btu/h / 18:18000Btu/h models •Operating data under running indoor units are shown on the above table. •2 or more indoor units should be connected. •Heating capacity is based on 20ºCDB (indoor temperature), 7ºCDB/6ºCWB (outdoor temperature). •Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) •The Total ability of connected a indoor unit is up to 36000Btu from 14000Btu. *1: When ASYG18L is connected, connect at least 1 wall mounted type for 9000Btu.

Page 42: Fujitsu 2012 catalog

083082

Multi Combination Table

79

1214182479

121418249

1214182412141824141824182479

121418249

121418241214182414182418249

1214182412141824141824181214182414181879

1214189

12141812141814189

1214181214181418121418149

1214

18*1

1214

18*2

1412141412

------77777799999

12121212141414181877777799999

12121212141414181899999

121212121414141812121212141418777779999

12121214149999

1212121414121212149999

1212121412121412

--------------------------777777777777777777779999999999999

1212121212121277777777777777999999999

1212121299999999

12121212

------------------------------------------------------------------77777777777777777777777777799999999999

12

2.30 ( 1.6 - 2.7 )2.70 ( 1.6 - 3.4 )3.50 ( 1.6 - 3.8 )4.00 ( 1.7 - 4.5 )5.20 ( 1.7 - 6.0 )6.80 ( 1.8 - 7.4 )4.60 ( 1.8 - 5.2 )5.00 ( 1.8 - 6.0 )5.80 ( 1.8 - 6.2 )6.30 ( 1.8 - 7.1 )6.90 ( 2.8 - 8.2 )7.20 ( 2.8 - 9.3 )5.40 ( 1.8 - 6.4 )6.20 ( 2.8 - 6.8 )6.70 ( 2.8 - 7.8 )7.00 ( 2.8 - 8.7 )7.30 ( 2.8 - 9.5 )6.70 ( 2.8 - 7.3 )6.90 ( 2.8 - 8.5 )7.00 ( 2.8 - 9.1 )7.30 ( 2.8 - 9.5 )7.10 ( 2.8 - 9.0 )7.20 ( 2.8 - 9.3 )7.40 ( 3.4 - 9.7 )7.40 ( 3.4 - 9.7 )7.50 ( 3.4 - 9.9 )6.90 ( 1.8 - 7.5 )7.30 ( 2.8 - 7.7 )7.00 ( 2.8 - 8.2 )7.20 ( 1.6 - 8.9 )7.70 ( 2.8 - 10.0 )7.80 ( 2.8 - 10.1 )7.00 ( 2.8 - 8.3 )7.20 ( 1.6 - 8.9 )7.20 ( 2.8 - 9.1 )7.70 ( 2.8 - 9.9 )7.80 ( 2.8 - 10.1 )7.20 ( 1.6 - 9.1 )7.30 ( 2.8 - 9.2 )7.70 ( 2.8 - 9.9 )7.80 ( 2.8 - 10.1 )7.30 ( 2.8 - 9.3 )7.70 ( 3.5 - 10.0 )7.90 ( 3.5 - 10.1 )7.80 ( 3.5 - 10.1 )7.90 ( 4.7 - 10.1 )7.20 ( 2.8 - 8.9 )7.20 ( 2.8 - 9.1 )7.30 ( 2.8 - 9.2 )7.70 ( 2.8 - 9.9 )7.80 ( 2.8 - 10.1 )7.20 ( 2.8 - 9.1 )7.30 ( 2.8 - 9.2 )7.70 ( 2.8 - 9.9 )7.80 ( 2.8 - 10.1 )7.30 ( 3.5 - 9.3 )7.80 ( 3.5 - 10.0 )7.90 ( 3.5 - 10.1 )7.80 ( 4.7 - 10.1 )7.30 ( 2.8 - 9.2 )7.40 ( 2.8 - 9.3 )7.80 ( 3.5 - 10.0 )7.90 ( 3.5 - 10.1 )7.40 ( 3.5 - 9.4 )7.80 ( 3.5 - 10.1 )7.90 ( 4.7 - 10.1 )7.60 ( 1.6 - 9.6 )7.60 ( 1.6 - 9.8 )7.70 ( 1.6 - 9.9 )7.70 ( 2.8 - 9.9 )8.00 ( 2.8 - 10.1 )7.70 ( 2.8 - 9.7 )7.70 ( 2.8 - 9.9 )7.70 ( 2.8 - 10.0 )8.00 ( 3.5 - 10.1 )7.70 ( 2.8 - 10.0 )7.80 ( 2.8 - 10.0 )8.00 ( 3.5 - 10.1 )8.00 ( 3.5 - 10.1 )8.00 ( 3.5 - 10.1 )7.70 ( 2.8 - 9.9 )7.70 ( 2.8 - 10.0 )7.80 ( 3.5 - 10.1 )8.00 ( 3.5 - 10.1 )7.80 ( 2.8 - 10.0 )7.80 ( 3.5 - 10.1 )8.00 ( 3.5 - 10.1 )7.90 ( 3.5 - 10.1 )8.00 ( 4.7 - 10.1 )7.80 ( 2.8 - 10.1 )7.90 ( 3.5 - 10.1 )8.00 ( 3.5 - 10.1 )7.90 ( 3.5 - 10.1 )7.70 ( 3.5 - 10.0 )7.80 ( 3.5 - 10.0 )7.80 ( 3.5 - 10.1 )8.00 ( 4.7 - 10.1 )7.80 ( 3.5 - 10.1 )7.80 ( 3.5 - 10.1 )8.00 ( 4.7 - 10.1 )7.90 ( 4.7 - 10.1 )7.80 ( 3.5 - 10.1 )7.90 ( 3.5 - 10.1 )7.90 ( 4.7 - 10.1 )8.00 ( 3.5 - 10.1 )

0.78 ( 0.56 - 0.99 )0.94 ( 0.56 - 1.25 )1.24 ( 0.56 - 1.40 )1.40 ( 0.57 - 1.68 )1.68 ( 0.56 - 2.20 )2.40 ( 0.56 - 2.86 )1.42 ( 0.60 - 1.62 )1.60 ( 0.60 - 2.16 )2.00 ( 0.60 - 2.20 )2.15 ( 0.60 - 2.50 )2.10 ( 0.90 - 2.85 )2.16 ( 0.90 - 3.58 )1.68 ( 0.60 - 2.23 )2.16 ( 0.90 - 2.50 )2.35 ( 0.90 - 2.90 )2.15 ( 0.90 - 3.25 )2.15 ( 0.90 - 3.52 )2.36 ( 0.90 - 2.80 )2.18 ( 0.90 - 3.30 )2.15 ( 0.90 - 3.52 )2.15 ( 0.90 - 3.52 )2.20 ( 0.90 - 3.40 )2.20 ( 0.90 - 3.52 )2.20 ( 1.10 - 3.52 )2.20 ( 1.10 - 3.52 )2.20 ( 1.10 - 3.52 )2.20 ( 0.60 - 2.44 )2.35 ( 0.90 - 2.55 )2.17 ( 0.90 - 2.90 )2.22 ( 0.68 - 3.43 )2.22 ( 0.98 - 3.55 )2.19 ( 0.98 - 3.53 )2.17 ( 0.90 - 2.90 )2.22 ( 0.68 - 3.41 )2.22 ( 0.98 - 3.56 )2.22 ( 0.98 - 3.56 )2.19 ( 0.98 - 3.53 )2.22 ( 0.68 - 3.54 )2.22 ( 0.98 - 3.56 )2.22 ( 0.98 - 3.56 )2.19 ( 0.98 - 3.56 )2.22 ( 0.98 - 3.58 )2.22 ( 1.17 - 3.58 )2.20 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.58 )2.22 ( 1.27 - 3.58 )2.22 ( 0.98 - 3.42 )2.22 ( 0.98 - 3.54 )2.22 ( 0.98 - 3.57 )2.22 ( 0.98 - 3.56 )2.20 ( 1.17 - 3.54 )2.22 ( 0.98 - 3.54 )2.22 ( 0.98 - 3.57 )2.22 ( 0.98 - 3.56 )2.19 ( 0.98 - 3.56 )2.22 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.58 )2.22 ( 1.27 - 3.56 )2.22 ( 1.27 - 3.58 )2.22 ( 0.98 - 3.55 )2.22 ( 0.98 - 3.58 )2.22 ( 1.17 - 3.57 )2.20 ( 1.17 - 3.54 )2.22 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.58 )2.22 ( 1.27 - 3.58 )2.20 ( 0.68 - 3.41 )2.22 ( 0.68 - 3.54 )2.22 ( 0.68 - 3.54 )2.22 ( 0.98 - 3.56 )2.20 ( 0.98 - 3.55 )2.22 ( 0.98 - 3.42 )2.22 ( 0.98 - 3.55 )2.22 ( 0.98 - 3.57 )2.20 ( 1.17 - 3.55 )2.22 ( 0.98 - 3.55 )2.22 ( 0.98 - 3.57 )2.20 ( 1.17 - 3.56 )2.22 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.58 )2.22 ( 0.98 - 3.56 )2.22 ( 0.98 - 3.56 )2.22 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.56 )2.22 ( 0.98 - 3.56 )2.22 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.56 )2.22 ( 1.17 - 3.58 )2.22 ( 1.27 - 3.57 )2.22 ( 0.98 - 3.56 )2.22 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.56 )2.22 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.56 )2.22 ( 1.17 - 3.57 )2.22 ( 1.17 - 3.58 )2.22 ( 1.27 - 3.58 )2.22 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.58 )2.22 ( 1.27 - 3.58 )2.22 ( 1.27 - 3.58 )2.22 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.58 )2.22 ( 1.27 - 3.58 )2.22 ( 1.17 - 3.58 )

2.95 2.87 2.82 2.86 3.10 2.83 3.24 3.13 2.90 2.93 3.29 3.33 3.21 2.87 2.85 3.26 3.40 2.84 3.17 3.26 3.40 3.23 3.27 3.36 3.36 3.41 3.14 3.11 3.23 3.24 3.47 3.56 3.23 3.24 3.24 3.47 3.56 3.24 3.29 3.47 3.56 3.29 3.47 3.59 3.51 3.56 3.24 3.24 3.29 3.47 3.55 3.24 3.29 3.47 3.56 3.29 3.51 3.56 3.51 3.29 3.33 3.51 3.59 3.33 3.51 3.56 3.45 3.42 3.47 3.47 3.64 3.47 3.47 3.47 3.64 3.47 3.51 3.64 3.60 3.60 3.47 3.47 3.51 3.60 3.51 3.51 3.60 3.56 3.60 3.51 3.56 3.60 3.56 3.47 3.51 3.51 3.60 3.51 3.51 3.60 3.56 3.51 3.56 3.56 3.60

CCCCBCABCCAAACCAACBAAAAAAABBAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

1Room

2Room

3Room

4Room

COOLING OPERATIONCooling Capacity

2.30 2.70 3.50 4.00 5.20 6.80 2.30 2.70 3.50 4.00 4.80 5.40 2.70 3.50 4.00 4.60 5.23 3.35 3.68 4.18 4.82 3.55 4.07 4.66 3.70 4.25 2.30 2.70 3.02 3.27 4.08 4.57 2.45 2.78 3.16 3.96 4.46 2.62 3.04 3.78 4.28 2.81 3.52 4.07 3.19 3.68 2.40 2.68 3.11 3.85 4.35 2.53 2.95 3.68 4.18 2.73 3.48 3.98 3.12 2.43 2.85 3.57 4.07 2.64 3.34 3.05 1.90 2.07 2.37 2.75 3.43 2.04 2.30 2.68 3.35 2.20 2.60 3.22 2.50 3.04 1.98 2.24 2.64 3.27 2.17 2.54 3.15 2.41 2.98 2.08 2.47 3.04 2.32 1.93 2.21 2.58 3.20 2.12 2.48 3.09 2.36 2.03 2.41 2.27 2.00

Room 1KW

------

2.30 2.30 2.30 2.30 2.10 1.80 2.70 2.70 2.70 2.40 2.07 3.35 3.22 2.82 2.48 3.55 3.13 2.74 3.70 3.25 2.30 2.30 1.99 1.96 1.81 1.61 2.45 2.34 2.14 1.98 1.77 2.62 2.43 2.24 2.01 2.81 2.61 2.39 3.19 2.92 2.40 2.26 2.10 1.93 1.73 2.53 2.36 2.18 1.97 2.73 2.58 2.34 3.12 2.43 2.28 2.12 1.92 2.64 2.48 3.05 1.90 1.84 1.78 1.65 1.52 2.04 1.94 1.81 1.67 2.20 2.08 1.91 2.50 2.25 1.98 1.89 1.78 1.64 2.17 2.03 1.87 2.41 2.21 2.08 1.98 1.80 2.32 1.93 1.86 1.74 1.60 2.12 1.98 1.83 2.36 2.03 1.93 2.27 2.00

Room 2KW

------------------------------------------------------------------

1.90 1.84 1.78 1.65 1.52 1.81 1.73 1.61 1.49 1.65 1.56 1.43 1.50 1.35 1.76 1.68 1.59 1.45 1.63 1.52 1.40 1.45 1.32 1.56 1.48 1.35 1.39 1.93 1.86 1.74 1.60 1.78 1.67 1.54 1.59 1.71 1.63 1.53 2.00

Room 4KW

--------------------------

2.30 2.30 1.99 1.96 1.81 1.61 2.09 2.08 1.90 1.76 1.57 1.96 1.83 1.68 1.51 1.68 1.57 1.44 1.42 1.30 2.40 2.26 2.10 1.93 1.73 2.14 1.99 1.84 1.66 1.84 1.74 1.58 1.56 2.43 2.28 2.12 1.92 2.11 1.98 1.81 1.90 1.84 1.78 1.65 1.52 1.81 1.73 1.61 1.49 1.65 1.56 1.43 1.50 1.35 1.98 1.89 1.78 1.64 1.83 1.71 1.58 1.63 1.49 2.08 1.98 1.80 1.86 1.93 1.86 1.74 1.60 1.78 1.67 1.54 1.59 2.03 1.93 1.82 2.00

Room 3KW

Total Capacity (min-max)KW

EER Energy efficiency class

KW

Input Power (min-max)AOYG30LAT4

2.70 ( 1.5 - 3.3 )3.30 ( 1.5 - 3.7 )3.80 ( 1.5 - 4.5 )4.80 ( 1.7 - 5.8 )6.00 ( 3.2 - 7.1 )8.20 ( 3.2 - 9.0 )5.40 ( 1.7 - 5.9 )6.00 ( 1.7 - 7.2 )6.50 ( 1.7 - 7.2 )7.50 ( 3.3 - 8.7 )8.70 ( 3.3 - 9.4 )9.50 ( 3.3 - 10.7 )6.60 ( 3.3 - 7.4 )7.10 ( 1.7 - 8.3 )8.10 ( 3.3 - 9.3 )9.10 ( 3.3 - 10.1 )9.50 ( 3.3 - 11.0 )7.60 ( 3.3 - 8.8 )8.60 ( 3.3 - 9.8 )9.30 ( 3.3 - 10.3 )9.60 ( 3.3 - 11.0 )9.40 ( 3.3 - 10.3 )9.60 ( 3.3 - 11.1 )9.60 ( 4.3 - 11.5 )9.60 ( 4.3 - 11.5 )9.60 ( 4.3 - 11.6 )8.10 ( 1.8 - 8.8 )8.70 ( 3.3 - 9.3 )9.20 ( 3.3 - 9.7 )9.00 ( 1.8 - 10.1 )9.40 ( 3.3 - 11.2 )9.50 ( 3.3 - 11.5 )9.30 ( 3.3 - 9.7 )9.00 ( 1.8 - 10.0 )9.10 ( 3.3 - 10.2 )9.40 ( 3.3 - 11.3 )9.60 ( 3.3 - 11.5 )9.00 ( 1.8 - 10.1 )9.20 ( 3.3 - 10.3 )9.50 ( 3.3 - 11.4 )9.60 ( 3.3 - 11.7 )9.30 ( 3.3 - 10.6 )9.50 ( 3.7 - 11.5 )9.60 ( 3.3 - 11.7 )9.60 ( 3.7 - 12.0 )9.60 ( 4.3 - 12.0 )9.00 ( 3.3 - 10.0 )9.00 ( 3.3 - 10.1 )9.20 ( 3.3 - 10.3 )9.50 ( 3.7 - 11.4 )9.60 ( 3.7 - 11.7 )9.10 ( 3.3 - 10.3 )9.30 ( 3.3 - 10.5 )9.50 ( 3.7 - 11.4 )9.60 ( 3.7 - 11.8 )9.30 ( 3.7 - 10.7 )9.50 ( 3.7 - 11.6 )9.60 ( 4.3 - 11.9 )9.60 ( 4.3 - 12.0 )9.20 ( 3.3 - 10.3 )9.30 ( 3.3 - 10.6 )9.50 ( 3.7 - 11.6 )9.60 ( 3.7 - 11.8 )9.40 ( 3.7 - 10.8 )9.50 ( 3.7 - 11.6 )9.60 ( 4.3 - 12.0 )9.40 ( 1.8 - 10.8 )9.50 ( 1.8 - 10.9 )9.50 ( 1.8 - 11.1 )9.60 ( 3.3 - 11.3 )9.60 ( 3.3 - 12.0 )9.50 ( 3.3 - 10.9 )9.50 ( 3.3 - 11.1 )9.60 ( 3.3 - 11.4 )9.60 ( 3.7 - 12.0 )9.60 ( 3.3 - 11.3 )9.60 ( 3.3 - 11.5 )9.60 ( 3.7 - 12.0 )9.60 ( 3.7 - 11.8 )9.60 ( 3.7 - 12.0 )9.50 ( 3.3 - 11.2 )9.60 ( 3.3 - 11.3 )9.60 ( 3.7 - 11.5 )9.60 ( 3.7 - 12.0 )9.60 ( 3.3 - 11.4 )9.60 ( 3.7 - 11.6 )9.60 ( 3.7 - 12.0 )9.60 ( 3.7 - 11.8 )9.60 ( 4.3 - 12.0 )9.60 ( 3.3 - 11.5 )9.60 ( 3.7 - 11.7 )9.60 ( 3.7 - 12.0 )9.60 ( 3.7 - 11.9 )9.60 ( 3.7 - 11.3 )9.60 ( 3.7 - 11.4 )9.60 ( 3.7 - 11.6 )9.60 ( 4.3 - 12.0 )9.60 ( 3.7 - 11.5 )9.60 ( 3.7 - 11.7 )9.60 ( 4.3 - 12.0 )9.60 ( 4.3 - 11.9 )9.60 ( 3.7 - 11.6 )9.60 ( 3.7 - 11.8 )9.60 ( 4.3 - 11.9 )9.60 ( 3.7 - 11.6 )

1.00 ( 0.55 - 1.25 )1.22 ( 0.55 - 1.41 )1.40 ( 0.55 - 1.80 )1.48 ( 0.58 - 1.90 )1.90 ( 0.90 - 2.46 )2.78 ( 0.90 - 3.33 )1.58 ( 0.55 - 1.80 )1.76 ( 0.55 - 2.50 )2.20 ( 0.55 - 2.45 )2.25 ( 0.90 - 2.88 )2.67 ( 0.90 - 3.00 )2.70 ( 0.90 - 3.50 )2.02 ( 0.90 - 2.50 )2.35 ( 0.55 - 3.08 )2.67 ( 0.90 - 3.30 )2.67 ( 0.90 - 3.40 )2.67 ( 0.90 - 3.50 )2.65 ( 0.90 - 3.30 )3.06 ( 0.90 - 3.50 )2.90 ( 0.90 - 3.50 )2.68 ( 0.90 - 3.50 )2.93 ( 0.90 - 3.50 )2.77 ( 0.90 - 3.50 )2.65 ( 1.02 - 3.50 )2.65 ( 1.02 - 3.50 )2.65 ( 1.02 - 3.50 )2.30 ( 0.55 - 2.65 )2.60 ( 0.90 - 2.85 )2.83 ( 0.90 - 3.10 )2.66 ( 0.58 - 3.53 )2.46 ( 0.87 - 3.52 )2.47 ( 0.87 - 3.52 )2.80 ( 0.90 - 3.10 )2.69 ( 0.58 - 3.51 )2.64 ( 0.87 - 3.50 )2.45 ( 0.87 - 3.50 )2.46 ( 0.87 - 3.51 )2.66 ( 0.58 - 3.48 )2.62 ( 0.87 - 3.48 )2.44 ( 0.87 - 3.47 )2.45 ( 0.87 - 3.56 )2.59 ( 0.87 - 3.48 )2.42 ( 0.97 - 3.52 )2.45 ( 0.87 - 3.56 )2.40 ( 0.97 - 3.52 )2.40 ( 1.12 - 3.52 )2.69 ( 0.87 - 3.51 )2.67 ( 0.87 - 3.48 )2.63 ( 0.87 - 3.48 )2.44 ( 0.97 - 3.48 )2.45 ( 0.97 - 3.57 )2.65 ( 0.87 - 3.52 )2.61 ( 0.87 - 3.52 )2.43 ( 0.97 - 3.47 )2.44 ( 0.97 - 3.55 )2.58 ( 0.97 - 3.46 )2.41 ( 0.97 - 3.51 )2.42 ( 1.12 - 3.57 )2.40 ( 1.12 - 3.52 )2.63 ( 0.87 - 3.49 )2.59 ( 0.87 - 3.49 )2.42 ( 0.97 - 3.52 )2.43 ( 0.97 - 3.54 )2.40 ( 0.97 - 3.50 )2.40 ( 0.97 - 3.49 )2.40 ( 1.12 - 3.52 )2.58 ( 0.58 - 3.47 )2.57 ( 0.58 - 3.51 )2.56 ( 0.58 - 3.55 )2.53 ( 0.87 - 3.56 )2.40 ( 0.87 - 3.56 )2.56 ( 0.87 - 3.44 )2.55 ( 0.87 - 3.54 )2.53 ( 0.87 - 3.54 )2.40 ( 0.97 - 3.55 )2.54 ( 0.87 - 3.57 )2.51 ( 0.87 - 3.58 )2.40 ( 0.97 - 3.58 )2.49 ( 0.97 - 3.58 )2.40 ( 0.97 - 3.56 )2.55 ( 0.87 - 3.54 )2.54 ( 0.87 - 3.58 )2.52 ( 0.97 - 3.58 )2.40 ( 0.97 - 3.58 )2.53 ( 0.87 - 3.58 )2.50 ( 0.97 - 3.58 )2.40 ( 0.97 - 3.58 )2.48 ( 0.97 - 3.58 )2.40 ( 1.12 - 3.58 )2.52 ( 0.87 - 3.58 )2.49 ( 0.97 - 3.58 )2.40 ( 0.97 - 3.56 )2.47 ( 0.97 - 3.58 )2.55 ( 0.97 - 3.58 )2.53 ( 0.97 - 3.58 )2.51 ( 0.97 - 3.58 )2.40 ( 1.12 - 3.58 )2.52 ( 0.97 - 3.58 )2.50 ( 0.97 - 3.58 )2.40 ( 1.12 - 3.58 )2.48 ( 1.12 - 3.58 )2.51 ( 0.97 - 3.58 )2.49 ( 0.97 - 3.58 )2.46 ( 1.12 - 3.58 )2.50 ( 0.97 - 3.58 )

2.70 2.70 2.71 3.24 3.16 2.95 3.42 3.41 2.95 3.33 3.26 3.52 3.27 3.02 3.03 3.41 3.56 2.87 2.81 3.21 3.58 3.21 3.47 3.62 3.62 3.62 3.52 3.35 3.25 3.38 3.82 3.85 3.32 3.35 3.45 3.84 3.90 3.38 3.51 3.89 3.92 3.59 3.93 3.92 4.00 4.00 3.35 3.37 3.50 3.89 3.92 3.43 3.56 3.91 3.93 3.60 3.94 3.97 4.00 3.50 3.59 3.93 3.95 3.92 3.96 4.00 3.64 3.70 3.71 3.79 4.00 3.71 3.73 3.79 4.00 3.78 3.82 4.00 3.86 4.00 3.73 3.78 3.81 4.00 3.79 3.84 4.00 3.87 4.00 3.81 3.85 4.00 3.89 3.76 3.79 3.82 4.00 3.81 3.84 4.00 3.87 3.82 3.86 3.90 3.84

EEECDDBBDCCBCDDBBDDCBCBAAABCCCAACCBAACBAABAAAACCBAABBAABAAABBAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

1Room

2Room

3Room

4Room

HEATING OPERATIONHeating Capacity

Total Capacity (min-max)KW

COP Energy efficiency class

KW

Input Power (min-max)AOYG30LAT4

2.70 3.30 3.80 4.80 6.00 8.20 2.70 3.30 3.80 4.80 6.00 7.15 3.30 3.80 4.80 5.87 6.77 3.80 4.80 5.69 6.56 4.70 5.33 6.06 4.80 5.54 2.70 3.30 3.80 4.15 4.86 5.44 3.30 3.56 4.00 4.66 5.29 3.33 3.80 4.45 5.03 3.60 4.19 4.77 3.89 4.42 3.00 3.39 3.87 4.52 5.11 3.22 3.69 4.29 4.86 3.46 4.04 4.62 3.76 3.07 3.49 4.07 4.65 3.32 3.85 3.60 2.35 2.68 3.06 3.49 4.00 2.57 2.95 3.36 3.87 2.82 3.20 3.69 3.03 3.51 2.47 2.87 3.25 3.74 2.72 3.09 3.58 2.94 3.41 2.59 2.95 3.43 2.81 2.40 2.76 3.14 3.62 2.63 2.99 3.47 2.84 2.51 2.87 2.73 2.40

Room 1KW

------

2.70 2.70 2.70 2.70 2.70 2.35 3.30 3.30 3.30 3.23 2.73 3.80 3.80 3.61 3.04 4.70 4.27 3.54 4.80 4.06 2.70 2.70 2.70 2.42 2.27 2.03 3.30 2.94 2.75 2.56 2.33 3.33 3.17 2.97 2.69 3.60 3.35 3.05 3.89 3.53 3.00 2.80 2.66 2.49 2.25 3.22 3.07 2.86 2.59 3.46 3.23 2.95 3.76 3.07 2.91 2.71 2.48 3.32 3.08 3.60 2.35 2.27 2.14 2.04 1.87 2.57 2.43 2.31 2.13 2.82 2.67 2.46 3.03 2.81 2.47 2.36 2.23 2.06 2.72 2.58 2.39 2.94 2.73 2.59 2.46 2.29 2.81 2.40 2.28 2.16 1.99 2.63 2.49 2.31 2.84 2.51 2.39 2.73 2.40

Room 2KW

------------------------------------------------------------------

2.35 2.27 2.14 2.04 1.87 2.18 2.06 1.96 1.80 1.98 1.87 1.72 1.77 1.64 2.09 2.01 1.89 1.75 1.91 1.80 1.67 1.71 1.59 1.81 1.72 1.60 1.64 2.40 2.28 2.16 1.99 2.17 2.06 1.91 1.96 2.07 1.97 1.87 2.40

Room 4KW

--------------------------

2.70 2.70 2.70 2.42 2.27 2.03 2.70 2.49 2.33 2.17 1.98 2.33 2.22 2.08 1.88 2.10 1.96 1.78 1.82 1.65 3.00 2.80 2.66 2.49 2.25 2.65 2.53 2.36 2.14 2.38 2.22 2.03 2.07 3.07 2.91 2.71 2.48 2.76 2.57 2.40 2.35 2.27 2.14 2.04 1.87 2.18 2.06 1.96 1.80 1.98 1.87 1.72 1.77 1.64 2.47 2.36 2.23 2.06 2.25 2.13 1.97 2.02 1.87 2.59 2.46 2.29 2.34 2.40 2.28 2.16 1.99 2.17 2.06 1.91 1.96 2.51 2.39 2.27 2.40

Room 3KW

Combination of indoor unit

Combination of indoor unit

79

1214182479

121418249

1214182412141824141824182479

121418249

121418241214182414182418249

1214182412141824141824181214182414181879

1214189

12141812141814189

1214181214181418121418149

1214

18*1

1214

18*2

1412141412

------77777799999

12121212141414181877777799999

12121212141414181899999

121212121414141812121212141418777779999

12121214149999

1212121414121212149999

1212121412121412

--------------------------777777777777777777779999999999999

1212121212121277777777777777999999999

1212121299999999

12121212

------------------------------------------------------------------77777777777777777777777777799999999999

12

4 Rooms Multi cooling 4 Rooms Multi heating

Note: •7:7000Btu/h / 9:9000Btu/h / 12:12000Btu/h / 14:14000Btu/h / 18:18000Btu/h / 24:24000Btu/h models •Operating data under running indoor units are shown on the above table. •3 or more indoor units should be connected. •Cooling capacity is based on 27ºCDB/19ºCWB (indoor temperature), 35ºCDB (outdoor temperature). •Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) •The Total ability of connected a indoor unit is up to 49000Btu from 27000Btu. *1: Connection of ASYG18L + ARYG09L + ARYG09L + ARYG09L is not available. All types other than this combination can be connected. *2: Connection of ASYG18L + ARYG12L + ARYG09L + ARYG09L is not available. All types other than this combination can be connected.

Note: •7:7000Btu/h / 9:9000Btu/h / 12:12000Btu/h / 14:14000Btu/h / 18:18000Btu/h / 24:24000Btu/h models •Operating data under running indoor units are shown on the above table. •3 or more indoor units should be connected. •Heating capacity is based on 20ºCDB (indoor temperature), 7ºCDB/6ºCWB (outdoor temperature). •Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) •The Total ability of connected a indoor unit is up to 49000Btu from 27000Btu. *1: Connection of ASYG18L + ARYG09L + ARYG09L + ARYG09L is not available. All types other than this combination can be connected. *2: Connection of ASYG18L + ARYG12L + ARYG09L + ARYG09L is not available. All types other than this combination can be connected.

Page 43: Fujitsu 2012 catalog

085084

Multi Combination Table

3Room

2Room

4Room

COOLING OPERATIONCooling Capacity

Room 1KW

Room 2KW

Room 4KW

Room 5KW

Room 6KW

Room 7KW

Room 8KW

Room 3KW

TotalKW KW

Input powerAOYG45LAT8 Combination of indoor unit

241818181414141414141212121212121212999999997777777

14141212121212121212121212999999999999999999999999977777777777777777777777777777

242418182418181414142418181414141212241818141412129

2418181414129

141414141412121212121212121414141412121212121212129999999999999

1814141414121212121212121212999999999997777

--

24182424182418142424182418142418242418241824182424241824182424141418141418141414121212121814141418141414121212121818141414121212129999

18181414141818141414121212121818141412121212999

24181814

---------------------------------

18141818141824181424181412182418141824181424181412241824181424181412241814121818241814241824181424181412241824182418141224181424241824

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

5.20 4.24 5.89 5.90 5.87 5.90 5.50 5.79 4.89 4.24 5.89 5.90 5.20 5.50 4.57 3.91 5.20 4.24 5.90 5.65 4.73 5.05 4.08 4.73 3.74 4.24 5.90 5.35 4.41 4.73 3.74 4.41 3.91 5.89 5.90 5.87 5.90 5.90 5.89 5.87 5.90 5.79 5.89 5.90 5.50 5.20 5.89 5.88 5.90 5.65 5.90 5.89 5.90 5.35 5.90 5.65 5.05 4.73 5.89 5.90 5.90 5.50 4.89 5.90 5.20 4.57 4.24 5.65 4.73 4.08 3.74 5.88 5.90 5.89 5.90 5.35 5.88 5.90 5.90 5.65 5.05 5.90 5.35 4.73 4.41 5.90 5.79 5.90 5.20 5.79 4.89 4.24 3.91 5.35 4.41 3.74 5.87 5.90 5.50 5.79

Note: •Cooling capacity is based on 27°CDB/19°CWB(indoor temperature),35°CDB(outdoor temperature) •Pipe Length: 5m (Outdoor unit to Branch box), 3m (Branch box to Indoor unit) •Height difference: 0m (Outdoor unit to Indoor unit) •The values in this table should be used only as a guide. These values are calculated at standard conditions. When you select models finally, select them according to “Model Selection” in the D&T manual

Note: •Cooling capacity is based on 27°CDB/19°CWB(indoor temperature),35°CDB(outdoor temperature) •Pipe Length: 5m (Outdoor unit to Branch box), 3m (Branch box to Indoor unit) •Height difference: 0m (Outdoor unit to Indoor unit) •The values in this table should be used only as a guide. These values are calculated at standard conditions. When you select models finally, select them according to “Model Selection” in the D&T manual

7.03 5.27 4.63 5.01 3.54 3.84 4.10 4.10 4.10 4.10 3.09 3.35 3.52 3.52 3.52 3.52 3.52 3.52 2.46 2.64 2.64 2.64 2.64 2.64 2.64 2.64 1.93 2.05 2.05 2.05 2.05 2.05 2.05 3.60 3.84 3.04 3.15 3.35 3.09 3.04 3.30 3.52 3.09 3.35 3.52 3.52 2.34 2.30 2.49 2.64 2.46 2.34 2.53 2.64 2.46 2.64 2.64 2.64 2.32 2.51 2.47 2.64 2.64 2.51 2.64 2.64 2.64 2.64 2.64 2.64 2.64 1.79 1.91 1.82 1.96 2.05 1.79 1.93 1.91 2.05 2.05 1.93 2.05 2.05 2.05 1.84 2.05 1.95 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 1.77 1.92 2.05 2.05

7.03 7.03 4.63 5.01 6.07 4.94 5.27 4.10 4.10 4.10 6.18 5.01 5.27 4.10 4.10 4.10 3.52 3.52 6.54 5.27 5.27 4.10 4.10 3.52 3.52 2.64 6.64 5.27 5.27 4.10 4.10 3.52 2.64 3.60 3.84 3.54 3.67 3.90 3.09 3.04 3.30 3.52 3.09 3.35 3.52 3.52 3.64 3.57 3.87 4.10 3.28 3.12 3.37 3.52 3.28 3.52 3.52 3.52 2.32 2.51 2.47 2.64 2.64 2.51 2.64 2.64 2.64 2.64 2.64 2.64 2.64 4.59 3.82 3.64 3.93 4.10 3.07 3.32 3.28 3.52 3.52 3.32 3.52 3.52 3.52 2.36 2.64 2.51 2.64 2.64 2.64 2.64 2.64 2.64 2.64 2.64 1.77 1.92 2.05 2.05

---------------------------------

4.63 3.84 4.55 4.72 3.90 4.63 6.07 4.94 4.10 6.18 5.01 4.10 3.52 4.67 6.12 4.97 4.10 4.90 6.23 5.05 4.10 6.54 5.27 4.10 3.52 6.18 5.01 6.59 5.27 4.10 6.68 5.27 4.10 3.52 7.03 5.27 4.10 3.52 4.59 4.91 6.24 5.05 4.10 6.12 4.97 6.54 5.27 4.10 6.63 5.27 4.10 3.52 6.29 5.27 6.68 5.27 7.03 5.27 4.10 3.52 7.03 5.27 4.10 6.07 6.59 5.27 7.03

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

--

6.18 5.01 6.07 6.59 5.27 7.03 5.27 4.10 6.18 6.68 5.27 7.03 5.27 4.10 7.03 5.27 6.54 7.03 5.27 7.03 5.27 7.03 5.27 7.03 6.64 7.03 5.27 7.03 5.27 7.03 7.03 3.60 3.84 4.55 3.67 3.90 4.63 3.54 3.84 4.10 3.09 3.35 3.52 3.52 4.67 3.57 3.87 4.10 4.90 3.64 3.93 4.10 3.28 3.52 3.52 3.52 4.63 5.01 3.84 4.10 4.10 3.35 3.52 3.52 3.52 2.64 2.64 2.64 2.64 4.59 4.91 3.64 3.93 4.10 4.59 4.97 3.82 4.10 4.10 3.32 3.52 3.52 3.52 4.72 5.27 3.90 4.10 3.52 3.52 3.52 3.52 2.64 2.64 2.64 6.07 4.94 5.27 4.10

14.06 12.30 15.45 15.03 15.68 15.37 14.64 15.23 13.47 12.30 15.45 15.04 14.06 14.65 12.89 11.72 14.07 12.31 15.54 14.94 13.18 13.77 12.01 13.19 11.43 12.31 15.21 14.35 12.59 13.18 11.42 12.60 11.72 15.45 15.37 15.68 15.21 15.04 15.45 15.69 15.38 15.24 15.45 15.05 14.66 14.08 15.33 15.57 15.21 14.94 15.54 15.33 14.87 14.36 15.55 14.95 13.78 13.20 15.45 15.04 15.38 14.65 13.48 15.05 14.07 12.90 12.32 14.95 13.19 12.02 11.44 15.56 15.54 15.33 14.87 14.35 15.57 15.21 15.54 14.94 13.77 15.21 14.36 13.19 12.61 15.21 15.23 15.04 14.06 15.24 13.48 12.31 11.73 14.36 12.60 11.43 15.68 15.37 14.64 15.23

8 Rooms Multi cooling 8 Rooms Multi cooling

4Room

5Room

6Room

COOLING OPERATIONCooling Capacity

Room 1KW

Room 2KW

Room 4KW

Room 5KW

Room 6KW

Room 7KW

Room 8KW

Room 3KW

TotalKW KW

Input powerAOYG45LAT8 Combination of indoor unit

777777777

121299999999999999999997777777777777777777777777777777777777777777777777777777777777799999777

777777777

12121212129999999999999999

121212121299999999999999999997777777777777777777777777777777777777799999999

14141212129977

12121212121412121212129999999999

141212121214141212121212999999999999

141412121212121299999999999997777777777777777799999999

1814241814241824181212141212141414121212141412121299999

1414121212141414141212121814141212121299999

1414181414121212181414141212121299999

181414141212121299999777799999

1299

---------

14121414121418141814121814181412241814129

14141814121814181418141218181424181412241814129

18141818142414121824181424181412241814129

1824181424181412241814129

241814121212999

121212

--------------------------------------------------------------------------------------------

141214129

121412

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

4.89 4.24 5.50 4.57 3.91 5.05 4.08 4.73 3.74 5.87 5.89 5.88 5.89 5.90 5.89 5.87 5.90 5.89 5.90 5.90 5.89 5.90 5.90 5.90 5.65 5.89 5.90 5.50 5.20 4.73 5.88 5.89 5.88 5.90 5.90 5.87 5.90 5.89 5.90 5.90 5.90 5.79 5.88 5.90 5.90 5.88 5.90 5.65 5.35 5.90 5.79 5.20 4.89 4.41 5.89 5.90 5.87 5.90 5.90 5.87 5.79 5.50 5.89 5.88 5.90 5.65 5.89 5.90 5.35 5.05 5.90 5.50 4.89 4.57 4.08 5.90 5.89 5.90 5.35 5.90 5.65 5.05 4.73 5.90 5.20 4.57 4.24 3.74 5.79 4.89 4.24 3.91 5.87 5.89 5.89 5.90 5.90 5.88 5.89 5.90

2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 3.04 3.09 2.30 2.34 2.46 2.32 2.28 2.36 2.32 2.47 2.51 2.34 2.49 2.46 2.53 2.64 2.32 2.51 2.64 2.64 2.64 1.79 1.82 1.79 1.91 1.93 1.77 1.84 1.80 1.92 1.83 1.95 2.05 1.79 1.91 1.96 1.79 1.93 2.05 2.05 1.83 2.05 2.05 2.05 2.05 1.80 1.92 1.77 1.84 1.95 1.77 2.05 2.05 1.82 1.79 1.93 2.05 1.82 1.96 2.05 2.05 1.92 2.05 2.05 2.05 2.05 1.91 1.82 1.96 2.05 1.91 2.05 2.05 2.05 1.95 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.28 2.32 2.34 2.46 2.51 1.78 1.80 1.83

2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 3.04 3.09 3.07 3.12 3.27 2.32 2.28 2.36 2.32 2.47 2.51 2.34 2.49 2.46 2.53 2.64 2.32 2.51 2.64 2.64 2.64 3.07 3.12 3.07 3.28 3.32 2.28 2.36 2.32 2.47 2.36 2.51 2.64 2.30 2.46 2.53 2.30 2.49 2.64 2.64 2.36 2.64 2.64 2.64 2.64 1.80 1.92 1.77 1.84 1.95 1.77 2.05 2.05 1.82 1.79 1.93 2.05 1.82 1.96 2.05 2.05 1.92 2.05 2.05 2.05 2.05 1.91 1.82 1.96 2.05 1.91 2.05 2.05 2.05 1.95 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.28 2.32 2.34 2.46 2.51 2.30 2.32 2.36

5.27 4.10 7.03 5.27 4.10 7.03 5.27 7.03 5.27 3.04 3.09 3.57 3.12 3.27 3.60 3.54 3.67 3.09 3.30 3.34 3.64 3.87 3.28 3.37 3.52 2.32 2.51 2.64 2.64 2.64 3.57 3.64 3.07 3.28 3.32 3.54 3.67 3.60 3.84 3.15 3.35 3.52 4.59 3.82 3.93 3.07 3.32 3.52 3.52 2.36 2.64 2.64 2.64 2.64 3.60 3.84 4.55 3.67 3.90 3.04 3.52 3.52 4.67 3.57 3.87 4.10 3.12 3.37 3.52 3.52 2.47 2.64 2.64 2.64 2.64 4.91 3.64 3.93 4.10 3.28 3.52 3.52 3.52 2.51 2.64 2.64 2.64 2.64 2.05 2.05 2.05 2.05 2.28 2.32 2.34 2.46 2.51 3.06 2.32 2.36

---------

3.54 3.09 3.57 3.63 3.27 3.60 4.55 3.67 4.63 3.84 3.34 4.67 3.87 4.90 3.93 3.52 6.18 5.01 4.10 3.52 2.64 3.57 3.64 4.59 3.82 3.32 4.55 3.67 4.63 3.84 4.72 3.90 3.52 4.59 4.90 3.93 6.12 4.97 4.10 3.52 6.29 5.27 4.10 3.52 2.64 4.63 3.84 4.55 4.72 3.90 6.07 4.10 3.52 4.67 6.12 4.97 4.10 6.23 5.05 4.10 3.52 6.59 5.27 4.10 3.52 2.64 4.91 6.24 5.05 4.10 6.54 5.27 4.10 3.52 6.68 5.27 4.10 3.52 2.64 7.03 5.27 4.10 3.52 3.04 3.09 2.34 2.46 2.51 3.06 3.09 3.15

--------------------------------------------------------------------------------------------

3.54 3.09 3.63 3.27 2.51 3.06 3.60 3.15

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

4.10 4.10 3.52 3.52 3.52 2.64 2.64 2.05 2.05 3.04 3.09 3.07 3.12 3.27 3.60 3.04 3.15 3.09 3.30 3.34 2.34 2.49 2.46 2.53 2.64 2.32 2.51 2.64 2.64 2.64 3.57 3.12 3.07 3.28 3.32 3.54 3.67 3.09 3.30 3.15 3.35 3.52 2.30 2.46 2.53 2.30 2.49 2.64 2.64 2.36 2.64 2.64 2.64 2.64 3.60 3.84 3.04 3.15 3.35 3.04 3.52 3.52 2.34 2.30 2.49 2.64 2.34 2.53 2.64 2.64 2.47 2.64 2.64 2.64 2.64 1.91 1.82 1.96 2.05 1.91 2.05 2.05 2.05 1.95 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.28 2.32 2.34 2.46 2.51 2.30 2.32 2.36

13.47 12.30 14.65 12.89 11.72 13.77 12.01 13.18 11.42 15.69 15.46 15.57 15.34 15.55 15.45 15.69 15.21 15.45 15.38 15.05 15.33 15.21 15.55 14.88 14.96 15.45 15.05 14.66 14.08 13.20 15.57 15.33 15.57 15.55 15.22 15.68 15.21 15.45 15.38 15.21 15.05 15.25 15.57 15.54 14.87 15.57 15.21 14.95 14.37 15.21 15.24 14.07 13.49 12.61 15.45 15.37 15.68 15.21 15.04 15.69 15.24 14.66 15.33 15.57 15.21 14.94 15.33 14.87 14.36 13.78 15.38 14.65 13.48 12.90 12.02 15.54 15.33 14.87 14.35 15.54 14.94 13.77 13.19 15.04 14.06 12.89 12.31 11.43 15.23 13.47 12.30 11.72 15.69 15.46 15.34 15.55 15.05 15.57 15.45 15.22

Page 44: Fujitsu 2012 catalog

087086

Multi Combination Table

3Room

2Room

4Room

HEATING OPERATIONHeating Capacity

Room 1KW

Room 2KW

Room 4KW

Room 5KW

Room 6KW

Room 7KW

Room 8KW

Room 3KW

TotalKW KW

Input powerAOYG45LAT8 Combination of indoor unit

241818181414141414141212121212121212999999997777777

14141212121212121212121212999999999999999999999999977777777777777777777777777777

242418182418181414142418181414141212241818141412129

2418181414129

141414141412121212121212121414141412121212121212129999999999999

1814141414121212121212121212999999999997777

--

24182424182418142424182418142418242418241824182424241824182424141418141418141414121212121814141418141414121212121818141414121212129999

18181414141818141414121212121818141412121212999

24181814

---------------------------------

18141818141824181424181412182418141824181424181412241824181424181412241814121818241814241824181424181412241824182418141224181424241824

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

5.07 4.21 5.98 5.43 5.98 5.70 5.11 5.23 4.75 4.21 5.98 5.43 5.07 5.11 4.46 4.00 5.07 4.21 5.87 5.16 4.60 4.91 4.10 4.60 3.90 4.21 5.56 5.08 4.33 4.60 3.90 4.33 4.00 5.98 5.70 5.98 5.98 5.43 5.98 5.98 5.70 5.23 5.98 5.43 5.11 5.07 5.98 5.98 5.56 5.16 5.87 5.98 5.32 5.08 5.87 5.16 4.91 4.60 5.98 5.43 5.70 5.11 4.75 5.43 5.07 4.46 4.21 5.16 4.60 4.10 3.90 5.98 5.87 5.98 5.32 5.08 5.98 5.56 5.87 5.16 4.91 5.56 5.08 4.60 4.33 5.98 5.23 5.43 5.07 5.23 4.75 4.21 4.00 5.08 4.33 3.90 5.98 5.70 5.11 5.23

7.91 5.86 5.32 5.79 4.26 4.59 4.78 4.75 4.80 4.80 3.58 3.84 3.96 3.94 3.96 3.96 3.96 3.96 2.85 2.97 2.99 2.99 2.99 2.99 2.99 2.99 2.28 2.37 2.37 2.37 2.37 2.37 2.37 4.30 4.55 3.53 3.61 3.80 3.59 3.52 3.79 3.92 3.58 3.84 3.94 3.96 2.72 2.66 2.87 2.96 2.86 2.71 2.90 2.98 2.85 2.97 2.99 2.99 2.71 2.90 2.86 2.98 2.99 2.89 2.99 2.99 2.99 2.97 2.99 2.99 2.99 2.14 2.26 2.14 2.29 2.36 2.13 2.29 2.25 2.35 2.37 2.28 2.37 2.37 2.37 2.25 2.35 2.29 2.37 2.35 2.37 2.37 2.37 2.37 2.37 2.37 2.11 2.27 2.36 2.35

7.91 7.91 5.32 5.79 7.02 5.61 5.84 4.75 4.80 4.80 7.15 5.68 5.86 4.78 4.80 4.80 3.96 3.96 7.54 5.83 5.86 4.80 4.80 3.96 3.96 2.99 7.61 5.85 5.86 4.80 4.80 3.96 2.99 4.30 4.55 4.28 4.38 4.61 3.59 3.52 3.79 3.92 3.58 3.84 3.94 3.96 4.37 4.27 4.60 4.75 3.78 3.59 3.85 3.94 3.77 3.94 3.96 3.96 2.71 2.90 2.86 2.98 2.99 2.89 2.99 2.99 2.99 2.97 2.99 2.99 2.99 5.28 4.57 4.33 4.65 4.77 3.56 3.82 3.76 3.93 3.96 3.81 3.96 3.96 3.96 2.84 2.97 2.88 2.99 2.96 2.99 2.99 2.99 2.98 2.99 2.99 2.11 2.27 2.36 2.35

---------------------------------

5.24 4.55 5.22 5.34 4.61 5.32 7.02 5.61 4.75 7.15 5.68 4.78 3.96 5.33 7.04 5.62 4.75 5.60 7.17 5.69 4.78 7.54 5.83 4.80 3.96 7.16 5.68 7.55 5.83 4.80 7.65 5.86 4.80 3.96 7.86 5.86 4.80 3.96 5.28 5.58 7.14 5.67 4.77 7.10 5.65 7.52 5.82 4.80 7.61 5.85 4.80 3.96 7.51 5.81 7.63 5.86 7.84 5.86 4.80 3.96 7.89 5.86 4.80 7.03 7.57 5.84 7.83

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

--

7.18 5.79 7.02 7.57 5.84 7.82 5.86 4.80 7.15 7.67 5.86 7.87 5.86 4.80 7.91 5.86 7.54 7.87 5.86 7.91 5.86 7.91 5.86 7.91 7.61 7.90 5.86 7.91 5.86 7.91 7.91 4.30 4.55 5.22 4.38 4.61 5.32 4.26 4.59 4.75 3.58 3.84 3.94 3.96 5.33 4.27 4.60 4.75 5.60 4.35 4.66 4.78 3.77 3.94 3.96 3.96 5.30 5.68 4.58 4.78 4.80 3.83 3.96 3.96 3.96 2.97 2.99 2.99 2.99 5.28 5.58 4.33 4.65 4.77 5.26 5.65 4.56 4.77 4.80 3.81 3.96 3.96 3.96 5.56 5.81 4.63 4.80 3.92 3.96 3.96 3.96 2.98 2.99 2.99 7.03 5.61 5.84 4.75

15.82 13.77 17.82 17.38 18.31 17.77 16.46 17.32 15.46 14.40 17.89 17.19 15.68 16.59 14.62 13.56 15.83 13.78 17.93 16.67 14.71 15.70 13.65 14.86 12.81 13.89 17.51 16.12 14.09 15.08 13.03 14.24 13.27 18.13 18.20 18.24 17.71 17.62 17.82 18.32 17.77 17.33 17.90 17.20 16.60 15.84 17.76 18.25 17.68 17.22 17.84 17.83 17.11 16.48 17.94 16.67 15.71 14.87 17.88 17.17 17.85 16.56 15.58 17.27 15.80 14.74 13.90 16.77 14.83 13.77 12.93 17.98 17.99 17.94 17.26 16.67 18.05 17.41 18.09 16.87 15.93 17.51 16.13 15.09 14.25 18.15 16.95 17.42 16.02 17.08 15.18 14.12 13.28 16.23 14.21 13.15 18.28 17.73 16.40 17.27

8 Rooms Multi cooling 8 Rooms Multi heating

6Room

7Room

8Room

COOLING OPERATIONCooling Capacity

Room 1KW

Room 2KW

Room 4KW

Room 5KW

Room 6KW

Room 7KW

Room 8KW

Room 3KW

TotalKW KW

Input powerAOYG45LAT8 Combination of indoor unit

77777777777777777777777777777777777777777777777777777777777777777777

99977777777777777777777777777777777777777797777777777777777777777777

999

129999999999777777777777777777777777777799977777777777777777777777

999

12121299999999

121212999999999777777777777777799999977777777777777777777

9991212121412121299991412121414121212999914141212129999977777799999999997777777777777777

18129121412141814121814129141412181418141218141291814181412241814129241814129799999912999121299997777797777

------------------------------------------9129141291214129141218141291814129799777

---------------------------------------------------------------991297

5.88 5.90 5.79 5.87 5.88 5.89 5.89 5.87 5.90 5.90 5.89 5.90 5.90 5.50 5.88 5.89 5.90 5.87 5.90 5.89 5.90 5.90 5.90 5.90 5.65 5.20 5.89 5.90 5.90 5.90 5.79 5.88 5.90 5.65 5.35 4.89 5.89 5.90 5.35 5.05 4.57 4.24 5.88 5.87 5.89 5.87 5.89 5.90 5.88 5.89 5.90 5.90 5.88 5.89 5.87 5.90 5.90 5.90 5.89 5.90 5.90 5.65 5.35 5.87 5.89 5.88 5.90 5.90

1.79 1.93 2.05 1.77 1.79 1.82 1.80 1.77 1.83 1.92 1.82 1.93 1.96 2.05 1.79 1.82 1.91 1.77 1.84 1.80 1.92 1.95 1.91 1.96 2.05 2.05 1.80 1.92 1.84 1.95 2.05 1.79 1.93 2.05 2.05 2.05 1.82 1.96 2.05 2.05 2.05 2.05 1.78 1.77 1.82 1.77 1.80 1.91 1.79 1.80 1.83 1.93 1.79 1.82 1.77 1.84 1.92 1.96 1.80 1.92 1.95 2.05 2.05 1.77 1.80 1.79 1.84 1.92

2.30 2.49 2.64 1.77 1.79 1.82 1.80 1.77 1.83 1.92 1.82 1.93 1.96 2.05 1.79 1.82 1.91 1.77 1.84 1.80 1.92 1.95 1.91 1.96 2.05 2.05 1.80 1.92 1.84 1.95 2.05 1.79 1.93 2.05 2.05 2.05 1.82 1.96 2.05 2.05 2.05 2.05 2.30 1.77 1.82 1.77 1.80 1.91 1.79 1.80 1.83 1.93 1.79 1.82 1.77 1.84 1.92 1.96 1.80 1.92 1.95 2.05 2.05 1.77 1.80 1.79 1.84 1.92

2.30 2.49 2.64 3.04 3.07 3.12 2.32 2.28 2.36 2.47 2.34 2.49 2.53 2.64 3.07 3.12 3.28 2.28 2.36 2.32 2.47 2.51 2.46 2.53 2.64 2.64 1.80 1.92 1.84 1.95 2.05 1.79 1.93 2.05 2.05 2.05 1.82 1.96 2.05 2.05 2.05 2.05 2.30 2.28 2.34 2.28 2.32 2.46 1.79 1.80 1.83 1.93 1.79 1.82 1.77 1.84 1.92 1.96 1.80 1.92 1.95 2.05 2.05 1.77 1.80 1.79 1.84 1.92

2.30 2.49 2.64 3.04 3.07 3.12 3.60 3.04 3.15 3.30 2.34 2.49 2.53 2.64 3.57 3.12 3.28 3.54 3.67 3.09 3.30 3.35 2.46 2.53 2.64 2.64 3.60 3.84 3.15 3.35 3.52 2.30 2.49 2.64 2.64 2.64 1.82 1.96 2.05 2.05 2.05 2.05 2.30 2.28 2.34 2.28 2.32 2.46 2.30 2.32 2.36 2.49 1.79 1.82 1.77 1.84 1.92 1.96 1.80 1.92 1.95 2.05 2.05 1.77 1.80 1.79 1.84 1.92

4.59 3.32 2.64 3.04 3.57 3.12 3.60 4.55 3.67 3.30 4.67 3.87 3.37 2.64 3.57 3.64 3.28 4.55 3.67 4.63 3.84 3.35 4.90 3.93 3.52 2.64 4.63 3.84 4.72 3.90 3.52 6.12 4.97 4.10 3.52 2.64 6.24 5.05 4.10 3.52 2.64 2.05 2.30 2.28 2.34 2.28 2.32 2.46 3.07 2.32 2.36 2.49 3.07 3.12 2.28 2.36 2.47 2.53 1.80 1.92 1.95 2.05 2.05 2.28 1.80 1.79 1.84 1.92

------------------------------------------

2.30 3.04 2.34 3.54 3.09 2.46 3.07 3.60 3.15 2.49 3.57 3.12 4.55 3.67 3.30 2.53 4.63 3.84 3.35 2.64 2.05 2.28 2.32 1.79 1.84 1.92

---------------------------------------------------------------

2.28 2.32 3.07 2.36 1.92

2.30 2.49 2.64 3.04 2.30 2.34 2.32 2.28 2.36 2.47 2.34 2.49 2.53 2.64 1.79 1.82 1.91 1.77 1.84 1.80 1.92 1.95 1.91 1.96 2.05 2.05 1.80 1.92 1.84 1.95 2.05 1.79 1.93 2.05 2.05 2.05 1.82 1.96 2.05 2.05 2.05 2.05 2.30 2.28 2.34 1.77 1.80 1.91 1.79 1.80 1.83 1.93 1.79 1.82 1.77 1.84 1.92 1.96 1.80 1.92 1.95 2.05 2.05 1.77 1.80 1.79 1.84 1.92

15.57 15.22 15.25 15.69 15.57 15.34 15.45 15.69 15.21 15.38 15.33 15.21 14.88 14.66 15.57 15.33 15.55 15.68 15.21 15.45 15.38 15.05 15.54 14.87 14.95 14.07 15.45 15.37 15.21 15.04 15.24 15.57 15.21 14.94 14.36 13.48 15.33 14.87 14.35 13.77 12.89 12.30 15.57 15.69 15.34 15.69 15.45 15.55 15.57 15.45 15.21 15.21 15.57 15.33 15.68 15.21 15.38 14.87 15.45 15.37 15.04 14.94 14.35 15.69 15.45 15.57 15.21 15.37

Note: •Cooling capacity is based on 27°CDB/19°CWB(indoor temperature),35°CDB(outdoor temperature) •Pipe Length: 5m (Outdoor unit to Branch box), 3m (Branch box to Indoor unit) •Height difference: 0m (Outdoor unit to Indoor unit) •The values in this table should be used only as a guide. These values are calculated at standard conditions. When you select models finally, select them according to “Model Selection” in the D&T manual

Note: •Heating capacity is based on 20°CDB(indoor temperature),7°CDB/6°CWB(outdoor temperature) •Pipe Length: 5m (Outdoor unit to Branch box), 3m (Branch box to Indoor unit) •Height difference: 0m (Outdoor unit to Indoor unit) •The values in this table should be used only as a guide. These values are calculated at standard conditions. When you select models finally, select them according to “Model Selection” in the D&T manual

Page 45: Fujitsu 2012 catalog

089088

Multi Combination Table

6Room

7Room

8Room

HEATING OPERATION

Room 1KW

Room 2KW

Room 4KW

Room 5KW

Room 6KW

Room 7KW

Room 8KW

Room 3KW

TotalKW KW

Input powerAOYG45LAT8Heating CapacityCombination

of indoor unit

77777777777777777777777777777777777777777777777777777777777777777777

99977777777777777777777777777777777777777797777777777777777777777777

999

129999999999777777777777777777777777777799977777777777777777777777

999

12121299999999

121212999999999777777777777777799999977777777777777777777

999

121212141212129999

14121214141212129999

14141212129999977777799999999997777777777777777

18129

121412141814121814129

14141218141814121814129

1814181412241814129

2418141297999999

12999

121299997777797777

------------------------------------------9

129

14129

1214129

14121814129

1814129799777

---------------------------------------------------------------99

1297

5.98 5.56 5.23 5.98 5.98 5.98 5.98 5.98 5.98 5.70 5.98 5.56 5.32 5.11 5.98 5.98 5.87 5.98 5.98 5.98 5.70 5.43 5.87 5.32 5.16 5.07 5.98 5.70 5.98 5.43 5.23 5.98 5.56 5.16 5.08 4.75 5.98 5.32 5.08 4.91 4.46 4.21 5.98 5.98 5.98 5.98 5.98 5.87 5.98 5.98 5.98 5.56 5.98 5.98 5.98 5.98 5.70 5.32 5.98 5.70 5.43 5.16 5.08 5.98 5.98 5.98 5.98 5.70

2.12 2.28 2.35 2.11 2.11 2.15 2.12 2.11 2.16 2.27 2.15 2.27 2.30 2.36 2.10 2.14 2.25 2.10 2.15 2.14 2.26 2.29 2.25 2.29 2.35 2.37 2.13 2.25 2.17 2.28 2.35 2.12 2.28 2.35 2.36 2.37 2.14 2.30 2.36 2.37 2.37 2.37 2.12 2.10 2.15 2.09 2.13 2.25 2.11 2.12 2.16 2.27 2.10 2.14 2.10 2.15 2.26 2.29 2.13 2.25 2.28 2.35 2.36 2.09 2.12 2.11 2.15 2.25

2.68 2.87 2.96 2.11 2.11 2.15 2.12 2.11 2.16 2.27 2.15 2.27 2.30 2.36 2.10 2.14 2.25 2.10 2.15 2.14 2.26 2.29 2.25 2.29 2.35 2.37 2.13 2.25 2.17 2.28 2.35 2.12 2.28 2.35 2.36 2.37 2.14 2.30 2.36 2.37 2.37 2.37 2.67 2.10 2.15 2.09 2.13 2.25 2.11 2.12 2.16 2.27 2.10 2.14 2.10 2.15 2.26 2.29 2.13 2.25 2.28 2.35 2.36 2.09 2.12 2.11 2.15 2.25

2.68 2.87 2.96 3.52 3.53 3.60 2.67 2.66 2.72 2.86 2.72 2.86 2.90 2.97 3.51 3.58 3.77 2.65 2.71 2.70 2.85 2.89 2.84 2.89 2.97 2.99 2.13 2.25 2.17 2.28 2.35 2.12 2.28 2.35 2.36 2.37 2.14 2.30 2.36 2.37 2.37 2.37 2.67 2.65 2.71 2.63 2.69 2.84 2.11 2.12 2.16 2.27 2.10 2.14 2.10 2.15 2.26 2.29 2.13 2.25 2.28 2.35 2.36 2.09 2.12 2.11 2.15 2.25

2.68 2.87 2.96 3.52 3.53 3.60 4.29 3.52 3.61 3.78 2.72 2.86 2.90 2.97 4.26 3.58 3.77 4.25 4.35 3.57 3.77 3.82 2.84 2.89 2.97 2.99 4.31 4.56 3.62 3.81 3.92 2.67 2.87 2.96 2.98 2.99 2.14 2.30 2.36 2.37 2.37 2.37 2.67 2.65 2.71 2.63 2.69 2.84 2.67 2.68 2.73 2.87 2.10 2.14 2.10 2.15 2.26 2.29 2.13 2.25 2.28 2.35 2.36 2.09 2.12 2.11 2.15 2.25

5.25 3.81 2.96 3.52 4.28 3.60 4.29 5.21 4.37 3.78 5.33 4.60 3.84 2.97 4.26 4.34 3.77 5.19 4.35 5.28 4.57 3.82 5.57 4.64 3.93 2.99 5.26 4.56 5.36 4.62 3.92 7.06 5.63 4.76 3.95 2.99 7.16 5.68 4.78 3.96 2.99 2.37 2.67 2.65 2.71 2.63 2.69 2.84 3.53 2.68 2.73 2.87 3.52 3.58 2.65 2.71 2.85 2.89 2.13 2.25 2.28 2.35 2.36 2.64 2.12 2.11 2.15 2.25

------------------------------------------

2.67 3.51 2.71 4.23 3.56 2.84 3.53 4.30 3.61 2.87 4.26 3.58 5.19 4.36 3.78 2.89 5.26 4.56 3.81 2.96 2.36 2.64 2.68 2.11 2.15 2.25

---------------------------------------------------------------

2.64 2.68 3.52 2.72 2.25

2.68 2.87 2.96 3.52 2.66 2.71 2.67 2.66 2.72 2.86 2.72 2.86 2.90 2.97 2.10 2.14 2.25 2.10 2.15 2.14 2.26 2.29 2.25 2.29 2.35 2.37 2.13 2.25 2.17 2.28 2.35 2.12 2.28 2.35 2.36 2.37 2.14 2.30 2.36 2.37 2.37 2.37 2.67 2.65 2.71 2.09 2.13 2.25 2.11 2.12 2.16 2.27 2.10 2.14 2.10 2.15 2.26 2.29 2.13 2.25 2.28 2.35 2.36 2.09 2.12 2.11 2.15 2.25

18.10 17.57 17.16 18.29 18.23 17.81 18.16 18.27 17.74 17.82 17.79 17.73 17.15 16.61 18.34 17.92 18.06 18.38 17.85 17.96 17.97 17.39 18.03 17.30 16.92 16.07 18.07 18.12 17.65 17.54 17.23 18.19 17.60 17.11 16.38 15.46 17.88 17.18 16.57 15.81 14.84 14.22 18.16 18.33 17.85 18.40 18.02 18.11 18.20 18.13 17.71 17.68 18.31 17.89 18.35 17.82 17.93 17.26 18.04 18.08 17.50 17.06 16.52 18.40 18.10 18.28 17.79 18.04

4Room

5Room

6Room

HEATING OPERATIONHeating Capacity

Room 1KW

Room 2KW

Room 4KW

Room 5KW

Room 6KW

Room 7KW

Room 8KW

Room 3KW

TotalKW KW

Input powerAOYG45LAT8 Combination of indoor unit

777777777

121299999999999999999997777777777777777777777777777777777777777777777777777777777777799999777

777777777

12121212129999999999999999

121212121299999999999999999997777777777777777777777777777777777777799999999

14141212129977

12121212121412121212129999999999

141212121214141212121212999999999999

141412121212121299999999999997777777777777777799999999

1814241814241824181212141212141414121212141412121299999141412121214141414121212181414121212129999914141814141212121814141412121212999991814141412121212999997777999991299

---------

1412141412141814181412181418141224181412914141814121814181418141218181424181412241814129181418181424141218241814241814122418141291824181424181412241814129241814121212999121212

--------------------------------------------------------------------------------------------

141214129

121412

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

4.75 4.21 5.11 4.46 4.00 4.91 4.10 4.60 3.90 5.98 5.98 5.98 5.98 5.87 5.98 5.98 5.98 5.98 5.70 5.43 5.98 5.56 5.87 5.32 5.16 5.98 5.43 5.11 5.07 4.60 5.98 5.98 5.98 5.87 5.56 5.98 5.98 5.98 5.70 5.98 5.43 5.23 5.98 5.87 5.32 5.98 5.56 5.16 5.08 5.98 5.23 5.07 4.75 4.33 5.98 5.70 5.98 5.98 5.43 5.98 5.23 5.11 5.98 5.98 5.56 5.16 5.98 5.32 5.08 4.91 5.70 5.11 4.75 4.46 4.10 5.87 5.98 5.32 5.08 5.87 5.16 4.91 4.60 5.43 5.07 4.46 4.21 3.90 5.23 4.75 4.21 4.00 5.98 5.98 5.98 5.87 5.43 5.98 5.98 5.98

2.37 2.37 2.36 2.37 2.37 2.37 2.37 2.37 2.37 3.51 3.58 2.66 2.71 2.85 2.67 2.66 2.72 2.71 2.86 2.89 2.71 2.86 2.85 2.90 2.97 2.70 2.89 2.97 2.99 2.99 2.10 2.14 2.13 2.25 2.28 2.09 2.14 2.13 2.26 2.25 2.28 2.35 2.13 2.25 2.29 2.12 2.28 2.35 2.37 2.17 2.35 2.37 2.37 2.37 2.12 2.25 2.11 2.16 2.28 2.11 2.35 2.36 2.16 2.11 2.27 2.35 2.15 2.34 2.36 2.37 2.27 2.36 2.37 2.37 2.37 2.26 2.14 2.30 2.36 2.25 2.35 2.37 2.37 2.29 2.37 2.37 2.37 2.37 2.35 2.37 2.37 2.37 2.65 2.70 2.71 2.85 2.89 2.12 2.13 2.17

2.37 2.37 2.36 2.37 2.37 2.37 2.37 2.37 2.37 3.51 3.58 3.52 3.59 3.77 2.67 2.66 2.72 2.71 2.86 2.89 2.71 2.86 2.85 2.90 2.97 2.70 2.89 2.97 2.99 2.99 3.51 3.57 3.56 3.76 3.81 2.64 2.71 2.69 2.85 2.84 2.88 2.96 2.69 2.84 2.89 2.68 2.88 2.97 2.98 2.74 2.96 2.99 2.99 2.99 2.12 2.25 2.11 2.16 2.28 2.11 2.35 2.36 2.16 2.11 2.27 2.35 2.15 2.34 2.36 2.37 2.27 2.36 2.37 2.37 2.37 2.26 2.14 2.30 2.36 2.25 2.35 2.37 2.37 2.29 2.37 2.37 2.37 2.37 2.35 2.37 2.37 2.37 2.65 2.70 2.71 2.85 2.89 2.68 2.69 2.74

5.86 4.80 7.87 5.86 4.80 7.91 5.86 7.91 5.86 3.51 3.58 4.27 3.59 3.77 4.28 4.26 4.37 3.58 3.78 3.83 4.36 4.59 3.78 3.84 3.93 2.70 2.89 2.97 2.99 2.99 4.25 4.33 3.56 3.76 3.81 4.24 4.34 4.32 4.57 3.76 3.82 3.92 5.27 4.56 4.64 3.55 3.81 3.93 3.95 2.74 2.96 2.99 2.99 2.99 4.30 4.55 5.23 4.38 4.61 3.52 3.92 3.94 5.34 4.28 4.61 4.75 3.60 3.92 3.95 3.96 2.86 2.98 2.99 2.99 2.99 5.58 4.34 4.65 4.77 3.77 3.93 3.96 3.96 2.89 2.99 2.99 2.99 2.99 2.35 2.37 2.37 2.37 2.65 2.70 2.71 2.85 2.89 3.55 2.69 2.74

---------

4.26 3.58 4.27 4.35 3.77 4.28 5.21 4.37 5.30 4.58 3.83 5.32 4.59 5.59 4.65 3.93 7.14 5.67 4.77 3.96 2.99 4.25 4.33 5.26 4.56 3.81 5.18 4.34 5.28 4.57 5.56 4.63 3.92 5.27 5.57 4.64 7.08 5.64 4.76 3.95 7.24 5.81 4.79 3.96 2.99 5.25 4.55 5.23 5.35 4.61 7.03 4.75 3.94 5.34 7.05 5.62 4.75 7.18 5.80 4.78 3.96 7.56 5.83 4.80 3.96 2.99 5.58 7.15 5.68 4.77 7.52 5.82 4.80 3.96 7.63 5.86 4.80 3.96 2.99 7.83 5.86 4.80 3.96 3.51 3.57 2.71 2.85 2.89 3.55 3.56 3.62

--------------------------------------------------------------------------------------------

4.25 3.57 4.34 3.77 2.89 3.55 4.31 3.62

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

4.80 4.80 3.94 3.96 3.96 2.99 2.99 2.37 2.37 3.51 3.58 3.52 3.59 3.77 4.28 3.52 3.60 3.58 3.78 3.83 2.71 2.86 2.85 2.90 2.97 2.70 2.89 2.97 2.99 2.99 4.25 3.57 3.56 3.76 3.81 4.24 4.34 3.57 3.77 3.76 3.82 3.92 2.69 2.84 2.89 2.68 2.88 2.97 2.98 2.74 2.96 2.99 2.99 2.99 4.30 4.55 3.53 3.62 3.80 3.52 3.92 3.94 2.72 2.67 2.87 2.96 2.72 2.96 2.98 2.99 2.86 2.98 2.99 2.99 2.99 2.26 2.14 2.30 2.36 2.25 2.35 2.37 2.37 2.29 2.37 2.37 2.37 2.37 2.35 2.37 2.37 2.37 2.65 2.70 2.71 2.85 2.89 2.68 2.69 2.74

15.40 14.34 16.53 14.56 13.50 15.64 13.59 15.02 12.97 18.32 17.90 18.26 17.84 17.95 18.19 18.30 17.77 17.88 17.86 17.28 17.82 17.77 17.92 17.19 16.78 17.94 17.25 16.67 15.92 14.95 18.37 17.95 18.06 18.10 17.52 18.40 17.88 17.99 18.01 18.16 17.43 17.09 18.04 18.07 17.34 18.11 17.49 16.97 16.24 17.63 17.05 16.12 15.30 14.33 18.10 18.16 18.21 17.68 17.58 18.29 17.28 16.54 17.73 18.22 17.64 17.16 17.80 17.36 16.43 15.65 17.81 16.51 15.52 14.68 13.71 17.95 17.91 17.22 16.62 18.05 16.81 15.87 15.03 17.38 15.96 14.90 14.06 13.09 17.22 15.34 14.28 13.44 18.36 17.94 17.88 18.00 17.33 18.12 18.05 17.63

Note: •Heating capacity is based on 20°CDB(indoor temperature),7°CDB/6°CWB(outdoor temperature) •Pipe Length: 5m (Outdoor unit to Branch box), 3m (Branch box to Indoor unit) •Height difference: 0m (Outdoor unit to Indoor unit) •The values in this table should be used only as a guide. These values are calculated at standard conditions. When you select models finally, select them according to “Model Selection” in the D&T manual

8 Rooms Multi heating 8 Rooms Multi heating

Note: •Heating capacity is based on 20°CDB(indoor temperature),7°CDB/6°CWB(outdoor temperature) •Pipe Length: 5m (Outdoor unit to Branch box), 3m (Branch box to Indoor unit) •Height difference: 0m (Outdoor unit to Indoor unit) •The values in this table should be used only as a guide. These values are calculated at standard conditions. When you select models finally, select them according to “Model Selection” in the D&T manual

Page 46: Fujitsu 2012 catalog

091090

Simultaneous Multi Twin / Triple

AOYG36LATT

CLASSA

ALLDC

AOYG45LATT

CLASSA

ALLDC

AOYG54LATT

CLASSA

ALLDC

Can support various installation scenes from office to commercial space by same place multi connection of up to 3units.

Indoor units distributed layout according to the shape and number of people and lighting conditions of the room even on wide floors and atypical floors. Ideal comfortable air flow distribution can be realized.

Low noise mode: Suppresses night time operating sound.Peak cut function: Suppresses maximum capacity and performs energy saving operation and can prevent breaker tripping.

Max 16 indoor units are simultaneously controlled with a wired remote controller.

Installation according tofloor layout

Installation according tolighting conditions

Installation according tolayout and lighting conditions

Specifications Dimensions Models: (Unit : mm)AOYG36LATT / AOYG45LATT / AOYG54LATT

Simultaneous control

Low ambient operation External input

Four directions piping connection is possible. The perfect route can be selected according to the installation.

Piping connection

50

40

30

20

10

0

-10

46°C

-15°C

Cooling

24°CHeating

-15°C

330

31

650132

400

362.

524

400

900

9

33031 12

Top view

1290

21

SU MO TU WE TH FR SA

7

3 126 9 15 18 21

Transmission cable

Indoor unit 0(Master)

WiredRemort Controller

Remote controller cable Bus wire

Indoor unit 1

Indoorunit 2

Indoorunit 14

Indoor unit 3

Indoor unit 15

Refrigerant pipe

Set the indoor unit number using DIP switch on indoor unit circuit board.

1Front 2

Bottom

3Right

4Back

Net Dimension H x W x DWeight

Power Source

kg(lbs)mm

V/ Ø/HzAUYG18LVLB

245x570x570

Model No. Indoor unitAUYG22LVLA

Compact CassetteAUYG24LVLA

230/1/50680/580/490/410

15 (33)UTG-UFYD-W

245x570x570

230/1/501030/830/600/450

17(36)UTG-UFYD-W

245x570x570

230/1/501030/830/600/450

17(36)UTG-UFYD-W

Net Dimension H x W x DWeightPiping Connections (Small / Large)

Operation RangeCoolingHeating

Max Pipe Length (Pre-Charge)

Refrigerant

Power Source

kg(lbs)mm

mm

mm

°CDB

V/ Ø/Hz

AOYG36LATT

1290x900x330

9.52/15.8875(30)

30

-15~24R410A

Model No. Outdoor unit AOYG45LATT AOYG54LATT

UTP-SX236A(Twin)

400/3/50

105(229)

Height Difference-15~46

1290x900x330

9.52/15.8875(30)

30

-15~24R410A

UTP-SX254A(Twin)

400/3/50

105(229)

-15~46

1290x900x330

9.52/15.8875(30)

30

-15~24R410A

UTP-SX254A(Twin)/UTP-SX354A(Triple)

400/3/50

105(229)

-15~46

Separation tube

*Different type and capacity indoor units can not be connected .

Air Flow (High)

Decoration Panel

Cooling H/M/L/Q m3/h

Net Dimension H x W x DWeight

Power Source

kg(lbs)mm

V/ Ø/HzARYG18LLTB

198 x 900 x 620

Model No. Indoor unitARYG22LMLA

DuctARYG24LMLA

230/1/50830/670/580/480

23 (51)270 x 1135 x 700

230/1/501100/910/750/580

38 (84)

ABYG18LVTB

199 x 990 x 655

ABYG22LVTAFloor/Ceiling Universal

ABYG24LVTA230/1/50

780/700/560/500

27 (60)199 x 990 x 655

230/1/50980/820/680/540

27 (60)

Air Flow (High) Cooling H/M/L/Q m3/h

Page 47: Fujitsu 2012 catalog

093092

Big Multi

CAPACITY(BTU)

45,00036,00030,000

(25,000)24,00018,000

Indoor Unit LineupCEILING(LARGE)

FLOOR/CEILINGUNIVERSALDUCTCASSETTE

CAPACITY(BTU)

45,00036,00030,000

(25,000)24,00018,000

Indoor Unit LineupCEILING(LARGE)

FLOOR/CEILINGUNIVERSALDUCTCASSETTE

Chargeless30m

Outdoor units can be grouped together in a row.

Hei

ght d

iffer

ence

: 30

m m

ax.

Actual pipe length : 50m max.

Indoor unit Indoor unit Indoor unit Indoor unit

Outdoor unit

Wired remotecontroller

UTB-YUB (option)

Refrigerant System (Simultaneous Operation) Gas pipe

Liquid pipe

Separation tube UTR-BP901

Gas pipe

Liquid pipe

Separation tube UTR-BP901

Outdoor units can be grouped together in a row.

Chargeless30m

Hei

ght d

iffer

ence

: 30

m m

ax.

Actual pipe length : 50m max.

Indoor unit Indoor unit

Indoor unit Indoor unitOutdoor unit

Wired remotecontroller

UTB-YUB (option)

Wired remotecontroller

UTB-YUB (option)

Refrigerant System (Individual Operation)

Model name

Specifications

Capacity

Moisture Removal

Power Source 220-240/1/505.20~5.305.50~5.60

17,800~18,10018,800~19,100

2.2080068056030

Sirocco x 2199x990x655

28Flare

9.53/15.8818~3016~30

-

Model name AJYA90EATA380-415/W4/50

25.40 -

9.40 -

16.20 -

63.00 2.70

-730360

9,800Propeller x 2

150x21,380x1,300x650

24357

27/1920/(15)35/24

7/6R407C3.1x2

9.53/19.05503030

0~52-10~21

CoolingHeatingCoolingHeating

HighMedLow

kW

BTU/h

m3/h

V/ø/Hz

W

mm

ºC

AirflowRate

Grille

Net Dimension H x W x DWeight

Connection MethodConnection Pipe Size (Smallø/Largeø)

Fan Motor OutputFan Type x Q’ty

l/h

CoolingHeating

Operation Range

mmkg

220-240/1/506.50~6.607.60~7.70

22,200~22,50025,900~26,300

3.4090078066040

Sirocco x 2199x990x655

30Flare

9.53/15.8818~3016~30

-

220-240/1/508.60~8.808.80~9.10

29,400~30,00030,000~31,000

4.00 1,2701,120860160

Sirocco x 4240x1,660x700

48Flare

9.53/15.8818~3016~30

-

220-240/1/5010.30~10.5010.50~10.70

35,200~36,00036,000~36,500

4.00 1,6601,5001,270160

Sirocco x 4240x1,660x700

48Flare

9.53/19.0518~3016~30

-

220-240/1/5012.40~12.7013.40~13.70

42,500~43,50046,000~47,000

5.501,8501,6601,430160

Sirocco x 4240x1,660x700

48Flare

9.53/19.0518~3016~30

-

220-240/1/506.95~7.057.60~7.85

23,700~24,10025,900~26,800

2.501,6001,4501,280

70Sirocco x 2

270x1,210x70043

Flare9.53/15.88

18~3016~30

-

220-240/1/508.60~8.808.80~9.10

29,400~30,00030,000~31,000

3.00 1,6501,5501,350275

Sirocco x 2270x1,210x700

43Flare

9.53/15.8818~3016~30

-

220-240/1/5010.30~10.5010.50~10.70

35,200~36,00036,000~36,500

4.00 2,0001,8001,600275

Sirocco x 2270x1,210x700

45Flare

9.53/19.0518~3016~30

-

220-240/1/5012.40~12.7013.40~13.70

42,500~43,50046,000~47,000

5.502,2002,0001,800275

Sirocco x 2270x1,210x700

45Flare

9.53/19.0518~3016~30

-

220-240/1/504.85~5.005.30~5.45

19,000~19,90021,000~21,600

2.1065055049014

Turbo x 1235x580x580(+70)

18Flare

9.53/15.8818~3016~30

UTG-UDYD-W

220-240/1/506.95~7.057.60~7.85

23,700~24,10025,900~26,800

2.501,17097077090

Turbo x 1296x830x830

38Flare

9.53/15.8818~3016~30

-

220-240/1/508.60~8.808.80~9.10

29,400~30,00030,000~31,100

3.00 1,2701,07088090

Turbo x 1296x830x830

38Flare

9.53/15.8818~3016~30

-

220-240/1/5010.30~10.5010.50~10.70

35,200~36,00035,800~36,500

4.00 1,5001,3001,100

90Turbo x 1

296x830x83040

Flare9.53/19.05

18~3016~30

-

220-240/1/5012.40~12.7013.40~13.70

42,300~43,40045,800~46,800

5.00 1,6501,4501,200

90Turbo x 1

296x830x83040

Flare9.53/19.05

18~3016~30

-

Power Source

Total Capacity CoolingHeatingCoolingHeatingCoolingHeating

CoolingHeatingCoolingHeating

CoolingHeating

CoolingHeating

HighLowHigh

Total Input Watts

Total Ampacity

Starting CurrentEERCOP

Fan Speed

Airflow RateFan Type x Q'tyFan Motor OutputNet Dimension H x W x DWeightNoise Level(Sound Pressure)

Condition

Refrigerant

Pipe

Operation(Outdoor)

Type

IndoorAir Temp.Outdoor

Air Temp.

Max LengthMax Height

Max Chargeless Length

Size

V/ø/Hz

kW

kW

W/W

r.p.m

A

A

m3/h

Wmmkg

db(A)

kgmm

DB/WB(ºC)

DB/WB(ºC)

m

ºC

ChargeLiquid/Gas

AJYA90TATA380-415/W4/50

25.40 28.60 9.40 10.00 16.20 17.00 63.00 2.70 2.86 730360

9,800Propeller x 2

150x21,380x1,300x650

24557

27/1920/(15)35/247/6

R407C3.1x2

9.53/19.05503030

0~52-10~21

AJYA90EATB380-415/W4/50

25.40 -

9.40 -

16.20 -

63.00 2.70

-730360

9,800Propeller x 2

150x21,380x1,300x650

24357

27/1920/(15)35/247/6

R407C6.00

12.70/28.58503030

0~52-10~21

AJYA90TATB380-415/W4/50

25.40 28.60 9.40 10.00 16.20 17.00 63.00 2.70 2.86 730360

9,800Propeller x 2

150x21,380x1,300x650

24557

27/1920/(15)35/247/6

R407C6.00

12.70/28.58503030

0~52-10~21

Individual Operation Simultaneous Operation

Outdoor unitIndoor unit

Indoor unit

Outdoor unit

ABYA18TATA ABYA24TATA ABYA30TATA ABYA36TATA ABYA45TATA ARXA25TATA ARXA30TATA ARXA36TATA ARXA45TATA AUXA18TATA AUYA25TATA AUYA30TATA AUYA36TATA AUYA45TATA

Simultaneous OperationFeatures of System Operations•Simultaneous Operating System suitable for large spaces such as offices, lobbies and waiting rooms of high-rise buildings.

•One controller can simultaneously control cooling or heating by 2~4 indoor units.

Individual OperationFeatures of System Operations•Individual Operating System is suitable for large spaces such as hotels,commercial spaces, offices and restaurants.

•The system can cool and heat individually, because it has two refrigeration cycles.

CASSETTE(COMPACT)

CASSETTE(COMPACT)

Dimensions Models: (Unit : mm)AJYA90EATA / AJYA90TATA / AJYA90EATB / AJYA90TATB

Top view

Front view Right viewRear view

1000850

678

1380

1300 703650400400250

304

392424

24long hole

Page 48: Fujitsu 2012 catalog

095094

Optional Parts for Split & Multi Split

Type

UTY-RNNYMUTY-RNNYMUTY-RNNYM

Refrigerant Piping Parts

UTP-SX236A / UTP-SX254A

Separation TubeFor 3-phase simultaneous multi

UTP-PY03A / UTP-PY02A

Branch BoxFor 8 Rooms Multi

UTP-SX354A

For 3-phase simultaneous multi For 8 Rooms Multi

UTP-SX248A

Liquid pipeuid pipe

Gas pipe

3 zones type 2 zones type

Controllers

UTY-DMMYMUTY-RNNYM

Central Remote ControllerFor 8 Rooms Multi

Wired Remote Controller Simple Remote Controller

UTY-RSNYM

Wired RemoteController

Simple Remote Controller

Central Remote Controller

Communication Kit

External Connect Kit

Auto Louver Grille Kit

Remote Sensor Unit

Long Life Filter

Flange

Drain PumpUnit

Wide Panel

PanelSpacer

Fresh Air Intake Kit

Air Outlet Shutter Plate

AdditionalGrille

Half Concealed Kit

Insulation for High Humidity

ExternalConnect Kit

ExternalConnect Kit(For Base heater)

Separation Tube

Branch Box

CeilingFloor Ceiling /Floor

DuctWall Mounted

Compact Compact

AUYF24LB

ARYF24LB, ARYA30/36LB,45LC

ASYG09/12LT

ASYG07/09/12/14LU

ASYG07/09/12LE

ASYG14LE

ASYG07/09/12LJ

ASYG18/24/30LF

ARYG07/09/12/14LLTB

ARY25/30/36/45UU

AGYF 09/12/14LA

AGYG09/12/14LV

ABYF24LB

AUYG07/09/12/14/18LVLB

AUYA30/36LB, 45/54LC

AUY25/30/36/45/54UU

ARYC45/54LC

ARY60UU

ABYG14/18LVTB

ABYA30/36LB, 45/54LC

ABY30/36/45/54UB

ARY90TL

ARYG18LLTB

ARY18UU

Large LargeSlim Compact Medium static High static

Oth

ers

Refri

geran

t pipi

ng pa

rts

Optional Parts ListConnection Units

For Individual & Centralized Control

AUY18UB

Cassette

UTY-RNNYMUTY-RNNYM

UTY-TWBXF UTY-XCBXE

UTY-XWZXZ5 UTY-XWZX

UTD-GXSA

UTD-GXSB

UTY-XSZX

UTD-LF25NA

UTD-RF204UTD-SF045T

UTZ-PX1NBA

UTG-AGYA-W

UTG-BGYA-W

UTZ-VXGAUTZ-VXAA

UTR-YDZCUTR-YDZB

UTZ-KXGA

UTR-STA

3-phase

Single Split (AOYA45 / 54LC)

UTY-XWZXZ3

UTY-XWZXZ4

8 Rooms Multi (AOYG45LAC8) Single Split (AOYD36 / 45 / 54LA) Simultaneous Multi (AOYD36 / 45 / 54LA)

UTP-SX248A

UTP-PY03A / UTP-PY02A

UTZ-KXGC

UTG-AGEA-W

UTG-AGDA-W

UTZ-PX1BBA

UTD-RF204

UTR-DPB24T

UTD-LF60KA

External Control Set UTD-ECS5A

UTY-XWZX

UTD-ECS5A UTD-ECS5A

UTD-ECS5A

UTY-XWZX UTY-XWZX

UTY-XCBXZ1

UTY-DMMYM UTY-DMMYM UTY-DMMYM

UTY-LRHYM UTY-LRJY1

UTY-LRHY1

UTY-LRHYA1

UTY-DMMYM

UTY-DMMYM

UTY-DMMYM

UTY-RSNYM UTY-RSNYM UTY-RSNYM

UTY-RSNYM

UTY-RSNYMUTY-RSNYM

UTY-RNNYMUTY-RNNYM

UTY-RSNYM

UTY-XWZX

UTY-XWZX

UTY-RNNYMUTY-RNNYM

Con

trol

lers

IR Receiver Kitwith Wireless Remote Controller

Panels

UTG-UDYD-W UTG-UFYB -W / UTG-UFYD-W UTG-UGYA-W

Decoration Panel

Oth

ers

Type

For Cassette type

UTY-XWZXZ2

UTP-SX236A / UTP-SX254A / UTP-SX354A

Single-phase

Page 49: Fujitsu 2012 catalog

097096

Optional Parts for Split & Multi Split

For Cassette type

For Floor type

For Duct type

For Ceiling type

Others

IR Receiver KitFor Cassette type

IR Receiver KitFor Duct type

UTY-LRHYA1

UTY-LRHY1 / UTY-LRJY1UTY-LRHYM

+

UTD-LF25NA UTZ-PX1BBA / UTZ-PX1NBA

Long-Life Filter

UTD-LF60KA

This kit is used to half conceal floor type indoor unitinto the wall.

UTR-STA

Half Concealed Kit

Shuts the air outlet when only using as 2 or 3 blow out.

Indoor unit950

Panel 600

600(mm)

Panel spacer

242mm

UTG-AGYA-W

Wide Panel

UTG-BGYA-W

Panel Spacer

UTZ-VXAA UTZ-VXGA

Fresh Air Intake Kit

UTG-AGDA-W

Additional Grille

For Cassette typeFor Compact Cassette type

UTR-YDZB UTR-YDZC

Air Outlet Shutter Plate

For Cassette typeFor Compact Cassette type

UTZ-KXGA / UTZ-KXGC

Insulation KitFor High Humidity

For Compact Cassette type / Cassette type

Insulation Kit

UTG-AGEA-W

Remote Sensor Unit

UTY-XSZX

Auto Louver Grille Kit

UTD-GXSA (For 07 / 09 / 12 / 14 type)UTD-GXSB (For 18 type)

Simple flat Auto Louver will provide comfort airflow and harmonize with luxury interior.

Wired RemoteController

Wireless RemoteController

4 steps selectable and auto swing

Auto Louver Grille Duct type

New amenity space can be offered by installing the Remote sensor.

Drain Pump Unit

Drain Pump Unit

UTR-DPB24T

Flange

UTD-RF204(Round)

UTD-SF045T(Square)

IR Receiver Kit

Duct type indoor unit

WirelessRemote Controller

Use to connect with various peripheral devices andair conditioner PC board.

Communication KitFor Compact Wall Mounted type

UTY-TWBXF / UTY-XCBXE / UTY-XCBXZ1

External Control SetFor Indoor Unit (Duct type only)

UTD-ECS5A

External Connect KitFor Outdoor unit

UTY-XWZXZ4

For AOYG45LAC8 (For Base heater)

UTY-XWZXZ3

For AOYA45 / 54LC, AOYG45LAC8

UTY-XWZXZ2

External Connect KitFor Indoor Unit *Duct type is excluded.

UTY-XWZX / UTY-XWZXZ5 For LT / LU only

Communication System

For AOYD36 / 45 / 54LA, AOYD36 / 45 / 54LA

Page 50: Fujitsu 2012 catalog

098

Comfort is required of spaces where people gather.VRF is a large multi system that effectively air conditions a wide range of spaces from large buildings to personal residences.This system makes a variety of spaces comfortable utilizing high environmental performance and powerful but pleasant operation.

TMAIRSTAGE creates a comfortable space with a wide range of series variations.

AIRSTAGETMS Heat recovery type

AIRSTAGETMJ-II Heat pump type

AIRSTAGETMV-II Heat pump type

Control Systems

Optional Parts for VRF

100

110

116

134

152

Page 51: Fujitsu 2012 catalog

101100

2.98*Cooling EER

3.15 *Heating COP

High Efficiency

Smooth operation deliveringhigh efficiencies

Operating system

Cooling and heating can be performed simultaneously within the same refrigerant circuit. Energy savings are made by transferring heat between the indoor units when in heat recovery operation.

Power accumulation technology

Flow rate to the indoor unit(s) is controlled through the use of 3 differently rated compressors operating in a sequential step arrangement. While power accumulation technology controls the circulating load of the refrigerant flow between those steps.

Comfortable Operation

Heat recovery operation

Heat recovery operation is a cooling/heating free operation system, cooling and heating can be performed simultaneously in the same refrigerant system according to user needs. At the moment, the Heat Recovery operation is an extremely superior type that provides a still greater energy saving effect by moving heat between indoor units that are performing the cooling and heating operations. This is by having the compressors act like a pump.

The configuration of 3 constant speed compressors with differing capacities and power accumulation technology ensure smooth step changes and highly efficient operation.

*EER/COP values are base on our own testing method.

High Reliability

Recovery operation

Outdoor Unit: In the event of compressor failure an alarm is automatically triggered and the remaining compressor(s) will continue to operate, thereby ensuring continuous operation when possible.

Comp.1

Comp.2

Comp.3

Improved Comfort

Quiet operation

Operational noise has been reduced yet further through the application of a new dual casing bell-mouth and large fan. When set to silent operation, noise levels can be reduced by 5-6dB(A) compared to normal operation.

55dB(A)

Normal operation mode

50dB(A)

Silent operation mode

(380V)

Maximum comfort frominbuilt flexibility

Heat recoveryAO90MPCMF

2

3 3 3

1

1 2

1 2 3

Req

uire

d c

apac

ity

Operating capacitylow High

High

Wide operating range

5040302010

0-10 -5°C

-15°C

52°CCooling

21°CHeating

Outdoor unit operates over an outdoor temperature range of -5°C to 52°C for cooling and -15°C to 21°C for heating.

50 to 130%

Connectable capacity of indoor units for one outdoor unit

High capacity connectionLong piping system design

Design Versatility

•Equivalent pipe length: 120m maximum.•Total pipe length: 200m maximum.

*When outdoor unit is located above indoor unit. When outdoor unit is located below the indoor unit the height difference is 40m maximum.

Height difference

50m max.

Actual pipe length

100m max.

Height difference

15m max.

One outdoor unit can control up to 16 indoor units (28kW) of different types and capacities.

Diagram

Flow of refrigerantPower accumulation

technology

Comp.3

Comp.2

Comp.1

MAX Connectable indoor unit

16

Oil recovery operation

After a fixed period of time the oil recovery operation automatically returns accumulated oil found in the refrigerant circuit and indoor units.

Indoor Unit: Each indoor unit operates independently from the others and is, therefore, not affected by a failure within any part of the network.

Page 52: Fujitsu 2012 catalog

103102

Operation display

Easy Maintenance

By indicating the operating status and details of failures on a PCB in the outdoor unit, better service and quick and easy maintenance are possible.

Operating display

Pump down can be performed from the outdoor unit using the switch on the PCB.

Pump down control

A pull-out plate ensures easy compressor replacement if necessary.

Easy replacement

The outdoor unit can be lifted by crane and set down on the building roof.

Craning into place

Four-direction piping allows a variety of installation configurations. Easy installation and pipe direction setting.

Four-direction pipe

Easy Installation

Space saving

Space saving by setting side by side without space in between. 5.72Setting size

(Unit: m2)

Installation space

Top air outlet

Back sideintake port

Front sideintake port

L2L1

300mm or more

500mmor more

FRONTSIDE

10mm or more

300mmor more

1Front 2

Bottom

3Right

4Back

Protective boards

Dimensions

650

1,38

0

1,300

(Unit : mm)

800

1,500

1,05

0

Outdoor unit goes into elevator

Easy wiringTransmission line

PCcontroller

Central remote controller

Outdoor unit

TransmissionadaptorTransmission line

Indoor unit

There is no height restriction for the side wall. The height(H) of front and rear wall should be less than1,200mm. If the height of wall exceeds 1,200mm by h mm, add h mm to the service space width for L1 and L2.H 1,200 : L1 500, L2 300 H 1,200 + h : L1 500 + h, L2 300 + h

(Unit : mm)

Transmission line:Non-polar 2-conductor transmission line prevents erroneous wiring.

Power supply wiring:Power supply for outdoor and indoor units is different.

•Outdoor unit 3Ø 4W 380 - 415V 50Hz•Indoor unit: 1Ø 2W 220 - 240V 50Hz

hH

(120

0mm

)

hH

(120

0mm

)

10mm or more

10mm or more

10mmor more

10mmor more

10mmor more

500mmor more

FRONTSIDE

For individually For continuous

HPRating Capacity range

m3/h

kW

kW

mm

mmmmmm

˚C

W/W

dB(A)

kW

Capacity

Power source

kW

kgkg

CoolingHeatingCoolingHeatingCoolingHeatingHigh

CoolingMaximum Connectable Indoor UnitIndoor unit connectable capacity

Input power

EERCOPAir flow rate

Dimensions

WeightRefrigerant chargeConnection pipe diameterOperation range

Sound pressure levelCompressor motor outputHeat exchanger fin

HeightWidthDepth

LiquidGasCoolingHeating

10

AO90MPCMF

1614 to 36.4

3 phase, 380 - 415V, 50Hz28.031.59.4010.02.983.15

9,8005751

1.5 / 3.4 / 5.0Plate fin coil

1,3801,30065030511.8

ø12.70Discharge Gas ø19.05 / Suction Gas ø28.58

-5 to 52-15 to 21

Model name

Normal operation modeSilent operation mode

Specifications

Outdoor units specifications

Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.

Dimensions (Unit : mm)Model: AO90MPCMF

1000mm(Boltpitch)850mm

678m

m

650mm703mm

1300mm

1380

mm

Page 53: Fujitsu 2012 catalog

105104

Indoor units lineup 10 Types, 45 Models, Capacity range from 2.2 kW to 17.0 kW Indoor units of S series.

Compact Cassette

Cassette

High Static Pressure Duct

Duct

Floor / Ceiling

Ceiling

Wall Mounted

2.802.20Capacity range (kW)Model code

3.60 4.05 5.30 5.70 6.80 8.807.05 10.5 12.7 14.1 17.097 12 14 18 20 24 3025 36 45 54 60

Slim Type

AUXB07LATF AUXB09LATF AUXB12LATF AUXB18LATFAUXB14LATF

ARXB07LALF ARXB09LALF ARXB12LALF ARXB18LALFARXB14LALF

ABYA12LATF ABYA18LATFABYA14LATF

AWYA07LATF AWYA09LATF AWYA14LATFAWYA12LATF

ASYA18LATF

AWYA18LATF

ABYA24LATF

AUYA20LATF AUYA30LATFAUYA25LATF AUYA36LATF AUYA45LATF

ARXB30LATFARXB25LATF ARXB36LATF ARXB45LATF

ARXA30LATFARXA25LATF ARXA36LATF ARXA45LATF

ARXC36LATF ARXC45LATF ARXC60LATF

AUYA54LATF

ABYA30LATF

AWYA24LATF AWYA30LATF

ASYA24LATF ASYA30LATF

ABYA36LATF ABYA45LATF ABYA54LATF

Ceiling Wall

Low Static Pressure Duct

Silent model

Compact DuctSilent model

Page 54: Fujitsu 2012 catalog

107106

Indoor units specifications

Compact Cassette Compact DuctLow Static Pressure DuctDuct

Cassette

Model name

Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V]; Standard static pressure : 0 Pa(ARXB07LALF,ARXB09LALF,ARXB12LALF,ARXB18LALF,ARXB25LATF,ARXB30LATF,ARXB36LATF,ARXB45LATF)Voltage : 230 [V]; Standard static pressure :100 Pa(ARXA25LATF,ARXA30LATF,ARXA36LATF,ARXA45LATF)

Model name

Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].

Model name

Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V]; Standard static pressure : 100 Pa (ARXC36LATF, ARXC45LATF, ARXC60LATF).

Model name

Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].

High Static Pressure Duct

2.202.5031.2330300270

0 to 50292724

217x663x59518

ø6.35ø12.7

ARXB07LALF

ARXB09LALF

ARXB12LALF

ARXB18LALF

ARXB14LALF

CoolingHeating

HighMedLow

HighMedLow

Liquid (Flare)Gas (Flare)

2.803.2032.6370340310

0 to 50312927

217x663x59518

ø6.35ø12.7

4.004.8063.0610550470

0 to 50312926

217x953x59525

ø6.35ø12.7

5.305.60

103.0950790620

0 to 50403530

217x953x59525

ø9.52ø15.88

3.604.1055.0560500420

0 to 50302825

217x953x59525

ø6.35ø12.7

kW

W

m3/ h

Pa

dB(A)

mm

mm

kg

Power source

Capacity

Input power

Airflow rate

Static pressure range

Sound pressure level

Dimensions (H x W x D)WeightConnectionpipe diameter

7.007.70155

1,090970870

0 to 80292624

270x1,135x70043

ø9.52ø15.88

ARXB25LATF

ARXB30LATF

ARXB36LATF

ARXA25LATF

ARXA30LATF

ARXA36LATF

ARXA45LATF

ARXB45LATF

8.809.50171

1,2001,090970

0 to 80312826

270x1,135x70043

ø9.52ø15.88

12.714.3246

1,5801,4501,3200 to 80

373533

270x1,135x70045

ø9.52ø19.05

7.007.70161

1,1001,000900

30 to 150383634

270x1,135x70043

ø9.52ø15.88

8.809.50172

1,4001,3001,200

30 to 150403836

270x1,135x70043

ø9.52ø15.88

10.512.7220

1,7501,6501,550

30 to 150434139

270x1,135x70043

ø9.52ø19.05

12.714.3312

1,8001,6001,500

30 to 150444240

270x1,135x70045

ø9.52ø19.05

10.512.7216

1,4401,2701,160

0 to 80353230

270x1,135x70043

ø9.52ø19.05

230V~ , 50HzCoolingHeating

HighMedLowHighMedLow

Liquid (Flare)Gas (Flare)

kW

W

m3/ h

dB(A)

mm

mm

kg

Power source

Capacity

Input power

Airflow rate

Sound pressure level

Dimensions (H x W x D)WeightConnectionpipe diameterDecoration Panel

CoolingHeating

HighMedLow

HighMedLow

Liquid (Flare)Gas (Flare)

kW

W

m3/ h

Pa

dB(A)

mm

mm

kg

Power source

Capacity

Input power

Airflow rate

Static pressure range

Sound pressure level

Dimensions (H x W x D)WeightConnectionpipe diameter

CoolingHeating

HighMedLowHighMedLow

(Main body)(With Panel)

Liquid (Flare)Gas (Flare)

kW

W

m3/ h

dB(A)

mm

mm

kg

Power source

Capacity

Input power

Airflow rate

Sound pressure level

Dimensions (H x W x D)

WeightConnectionpipe diameter

2.20 2.5028530480410383531

230 x 570 x 57018

ø6.35ø12.7

AUXB07LATF AUXB09LATF AUXB12LATF AUXB18LATFAUXB14LATF

2.803.2028530480410383531

230 x 570 x 57018

ø6.35ø12.7

4.004.5052580520460413734

230 x 570 x 57018

ø6.35ø12.7

5.005.4550

640540470443835

230 x 570 x 57018

ø9.52ø15.88

230V~ , 50Hz 3.604.1052580520460413734

230 x 570 x 57018

ø6.35ø12.7

UTG-UDYD-W (Option)

5.705.80104

1,000840700413733

246 x 830 x 830265 x 940 x 940

34ø9.52

ø15.88

7.057.85124

1,100940780434035

246 x 830 x 830265 x 940 x 940

34ø9.52ø15.88

10.512.7175

1,5001,3001,100

4742.538

296 x 830 x 830315 x 940 x 940

40ø9.52

ø19.05

12.713.7190

1,5501,3501,10048.54641

296 x 830 x 830315 x 940 x 940

40ø9.52ø19.05

14.115.8219

1,7001,4201,20051.547.543.5

296 x 830 x 830315 x 940 x 940

40ø9.52

ø19.05

8.809.10140

1,2501,050840464337

246 x 830 x 830265 x 940 x 940

34ø9.52

ø15.88

AUYA20LATF AUYA25LATF AUYA30LATF AUYA45LATF AUYA36LATF AUYA54LATF

230V~ , 50Hz 10.5 12.7 405

2,5001,9501,450

100 to 200453832

400 x 1,050 x 50045

ø9.52(Flare)ø19.05 (Flare)

17.018.2427

3,5003,0002,460

100 to 250494542

400 x 1,050 x 50050

ø9.52(Flare)ø19.05 (Flare)

230V~ , 50Hz 12.714.3427

3,5003,0002,460

100 to 250494542

400 x 1,050 x 50045

ø9.52 (Flare)ø19.05 (Flare)

ARXC36LATF ARXC45LATF ARXC60LATF

Page 55: Fujitsu 2012 catalog

109108

Indoor units specifications

Floor / Ceiling

Ceiling

Model name

Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].

ABYA12LATF ABYA14LATF ABYA18LATF ABYA24LATF

Model name

Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].

ABYA30LATF ABYA36LATF ABYA45LATF ABYA54LATF

Model name ASYA18LATF ASYA24LATF ASYA30LATF

Model name

Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].

AWYA09LATFAWYA07LATF AWYA12LATF AWYA18LATFAWYA14LATF AWYA24LATF AWYA30LATF

Wall Mounted

CoolingHeating

HighMedLowHighMedLow

Liquid (Flare)Gas (Flare)

kW

W

m3/ h

dB(A)

mm

mm

kg

Power source

Capacity

Input power

Airflow rate

Sound pressure level

Dimensions (H x W x D)WeightConnectionpipe diameter

3.604.1057

640560480403734

199 x 990 x 65528

ø6.35ø12.7

4.055.0057

640560480403734

199 x 990 x 65528

ø6.35ø12.7

5.305.6088

78065055046

41.537

199 x 990 x 65528

ø9.52ø15.88

6.607.7088880740630484541

199 x 990 x 65528

ø9.52ø15.88

230V~ , 50Hz

CoolingHeating

HighMedLowHighMedLow

Liquid (Flare)Gas (Flare)

kW

W

m3/ h

dB(A)

mm

mm

kg

Power source

Capacity

Input power

Airflow rate

Sound pressure level

Dimensions (H x W x D)WeightConnectionpipe diameter

8.809.10124

1,4501,280980423935

240 x 1,660 x 70048

ø9.52ø15.88

10.512.7144

1,6601,5001,270

454237

240 x 1,660 x 70048

ø9.52ø19.05

12.713.7160

1,8501,6601,430

484641

240 x 1,660 x 70048

ø9.52ø19.05

14.115.8180

2,2002,0001,800

525046

240 x 1,660 x 70048

ø9.52ø19.05

230V~ , 50Hz

CoolingHeating

HighMedLowHighMedLow

Liquid (Flare)Gas (Flare)

kW

W

m3/ h

dB(A)

mm

mm

kg

Power source

Capacity

Input power

Airflow rate

Sound pressure level

Dimensions (H x W x D)WeightConnectionpipe diameter

5.405.6038

80065055041

36.533

320 x 1,120 x 22016

ø9.52ø15.88

6.907.8050

970870750454137

320 x 1,120 x 22016

ø9.52ø15.88

8.008.8060

1,04091073047.544

39.5320 x 1,120 x 220

16ø9.52ø15.88

230V~ , 50Hz

Ceiling Wall

CoolingHeating

HighMedLowHighMedLow

Liquid (Flare)Gas (Flare)

kW

W

m3/ h

dB(A)

mm

mm

kg

Power source

Capacity

Input power

Airflow rate

Sound pressure level

Dimensions (H x W x D)WeightConnectionpipe diameter

230V~ , 50Hz2.202.5016

380330290343230

270 x 1,150 x 28516

ø6.35ø12.7

2.803.2019

480420390353230

270 x 1,150 x 28516

ø6.35ø9.52

3.604.1020

600520470353331

270 x 1,150 x 28516

ø6.35ø12.7

5.405.6030

760660560403734

270 x 1,150 x 28516

ø9.52ø15.88

6.907.8040

900780650444137

270 x 1,150 x 28516

ø9.52ø15.88

8.008.8050

950870780474542

270 x 1,150 x 28516

ø9.52ø15.88

4.304.9021

650570490373532

270 x 1,150 x 28516

ø6.35ø12.7

Page 56: Fujitsu 2012 catalog

111110

Noi

se le

vel

Time

(4~6HP)

Rated noise value

-5dB ~ -6dB

Low noise mode

High Energy Saving

Advanced high efficiency technology

High seasonal efficiency

Our advanced high-efficiency technology achieves high performance within the actual usage performance range (50% load).

Large propeller fan :High performance and low noise realized by large propeller and optimization of angle.

DC fan motor :Miniaturized, low noise, high efficiency, multi-stage DC fan motor is mounted.

Large heat exchanger : Heat exchange performance is substan-tially improved by mounting of 3-row large heat exchanger.

DC inverter control :Efficiency is improved by mounting of new active filter module.

Subcool heat exchanger :Cooling performance is improved by mounting of dual tube heat exchanger.

DC twin rotary compressor :Efficiency in all load regions is good. Especially good performance from low to medium at normal operation.

100%

50%

0 COPCOPEEREER0

Cooling part loadCooling part load Heating part loadHeating part loadCooling EER

66% increase !

Heating COP

46% increase !

3.45 3.95

5.735.73 5.755.75Conditions : Connected indoor units: AUXD30LALH+AUXD24LALHCooling : indoor temp. of 27°CDB / 19°CWB, outdoor temp. of 35°CDB / 24°CWBHeating : indoor temp. of 20°CDB / 15°CWB, outdoor temp. of 7°CDB / 6°CWB*1. The data refers to a 6HP class outdoor unit.

*1 *1

More Comfort

Powerful Heating

Heating capacity is improved at low outdoor temperature by our advanced technology.

Low Noise Design

Low noise design of outdoor unitSignificantly reduced noise by optimized airflow structure design of outdoor unit.Low noise modeOutdoor unit can be switched to silent mode, depending on the installation environment.

Fujitsu General provides air conditioning systems for a wide range of applications from small office buildings and stores to large houses.

Heat pumpAJYA36LALH AJYA45LALH AJYA54LALH

Economy operationRoom temperature set point limitation

Various Energy Saving Function

The minimum and maximum temperature range can be set. The temperature setting is offset automatically over a certain period of time.

Heating Cooling

OriginalSet Temp.

Set point limitation setting

30

28

26

24

22

20

18

16

14

12

10

Cooling Set Temperature

Economy operationControl Temperature

Heating Set Temperature

Economy operationControl Temperature

Set Temp.

MAX. -4°C

MAX. +2°C

Economy operation

UpUp

Economy operation

Set Temp.

DownDown

DownDown

Capacity save operation The power consumption at peak is cut down.

(°C)

Various Comfort Control Function

Easy auto changeover functionAt the auto mode, cooling and heating mode is switched automatically to maintain the setting temperature.

Non-stop oil recovery operationThe product continues to operate without stopping the cooling or heating operation during oil recovery modes

Auto louver grill (Option for Slim Duct)

Auto louver grille provides comfort and efficient heating with louver controlled ductable outlet .

7

Current model (6HP class)

16.6

J-II series (6HP)

Outdoor temperature (°C)-20 -10 0

40

30

15 m20

25

35

Tem

pera

ture

(°C

)

Heating capacity (kW)

33%UP !

Page 57: Fujitsu 2012 catalog

113112

3 7 1 0 2 4 5 6

Easy to connect with V-II communication systemIt is possible to connect directly with the transmission cable of the V-II system without convertor.

J-II system V-II system

Connects without a converter

Automatic address setting function : The address of each indoor unit can be automatically set by button switch of outdoor unit.

Connection check function : Possible to confirm whether wiring connection and address setting are correct by check run function for a short time.

Press the push buttonof outdoor unit.

• Display connected indoor unit numbers• Duplicately set address number of

indoor unit can be displayed

More Design Flexibility

Long Piping Length

High Capacity Connection

Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length of 180 m. This opens up new possibilities in system design.

Easy Installation

Easier Installation

Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length of 180 m. This opens up new possibilities in system design.

Convenient Commissioning Support

CoolingCooling46°C

21°C

-5°C -5°C

-20°C -20°C

Heating

(°C)

-20°C areaOperation possiblein heating.

50

40

30

20

10

0

-10

-20

Number of connectable indoor unit

Wide operating range

Installation in extreme temperature conditions is possible due to an increase in operational range.Cooling : -5°C~46°CHeating : -20°C~21°C

12 types, 52 modelsIndoor unit

Connectable indoor unit capacity range

130 % max.

Easy piping connection : Improvement of the reliability by decreasing the flare connection.

Easy wiring connection• Decreasing wiring mistakes by using non-polar 2 wires. (Remote

controller cable is 3 wires)• Improvement of wiring installation by common with V-II power supply

method.

Flexible installation of outdoor unit : Corresponds to the outdoor unit concentration installation.

Reduced installation intervals by front access

Flexible installation by 4 way pipe direction

Flare connection

Terminal box

J-II series

Power supply cable

Power supply (Indoor )

Power supply(Outdoor )

Height difference between outdoor and indoor units

180m max.

Total pipe length

30m max.

Height difference between indoor and indoor units

15m max.

Actual piping length

120m max.

Piping length from first separation tube to the farthest indoor unit

40m max.

4 HP2 to 6

units

5 HP2 to 8

units

6 HP2 to 9

units

Flare connection

EV kitPrevious model

Page 58: Fujitsu 2012 catalog

115114

Easy Maintenance

Design for Easy Maintenance

Easy to read 7-segment LED : Confirm detail operational and trouble status without using specific equipment

Trouble diagnosis by Service Tool

Connection to Service Tool• Detail operation status and recent error history can be

checked and analyzed by using Service Tool.• Last 5 min. operation memory can be also recorded.

Emergency Stop Function

Specifications

Outdoor units specifications

Dimensions (Unit : mm)Model: AJYA36LALH / AJYA45LALH / AJYA54LALH

Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.The protective function might work when using it outside the operation range.

HPRating Capacity range

m3/h

kW

kW

mm

mmmmmm

˚C

W/W

dB(A)

kW

Capacity

Power source

kW

kgkg

CoolingHeatingCoolingHeatingCoolingHeatingHighCoolingHeating

CoolingMaximum Connectable Indoor UnitIndoor unit connectable capacity

Input power

EERCOPAir flow rate

Dimensions

WeightRefrigerant chargeConnection pipe diameterOperation range

Sound pressure levelCompressor motor outputHeat exchanger fin

HeightWidthDepth

LiquidGasCoolingHeating

Model name

5

AJYA45LALH

6

AJYA54LALH

65.6 to 14.5

Single-phase, ~230V, 50Hz11.212.52.802.764.004.53

6,2005052

3.75Blue fin1,3349703701174.8

ø9.52ø15.88-5 to 46

-20 to 21

87.0 to 18.2

Single-phase, ~230V, 50Hz14.016.03.893.813.604.20

6,4005153

3.75Blue fin1,3349703701175.3

ø9.52ø15.88-5 to 46

-20 to 21

97.8 to 20.1

Single-phase, ~230V, 50Hz15.518.04.494.563.453.95

6,9005355

3.75Blue fin1,3349703701175.3

ø9.52ø19.05-5 to 46

-20 to 21

4

AJYA36LALH

Emergencystop function

SU MO TU WE TH FR SA

Wired Remote Controller

Simple Remote Controller

Error status can be checked easily via the indoor unit wired controller. An error code is displayed on a liquid crystal screen.

Faulty unit number (Remote controller address)Error code

Remote controller address

Error code

Movable PCB panelEasier for maintenance work behind the PCB

7-segment LED

Emergency alarm can be received by indoor, outdoor units, Central Remote Controller or Touch Panel Controller when they received it, all units will be stopped.

Touch Panel Controller

CentralRemote Controller

or

Emergencystop function

Emergencystop function

T h P l

Central

Note : In case of received Emergency alarm by Indoor / outdoor unit : All units connected within same refrigerant system will be stopped. Central Remote Controller or Touch Panel Controller : all units connected within VRF network system with Central Remote Controller or Touch Panel Controller will be stopped.

Equipment Detail (Diagram)

Transmission cable (Non-polar 2 wires)

Service ToolUTY-ASGXUSB adaptor (Field supplied)

Software

Detail

650

970 32 12370

Terminal blocks (Transmission)

Terminal blocks (Power)

3-Way valve (Liquid)

3-Way valve (Gas)

Ø28 (Cable port)

Pipe portPipe port

Pipe & cable port

Pipe port89

50438

622

65 15

1450

21 55 21 65

166

370

43(L

iquid)

51(G

as)

(410

)40

3213

34

907

297

(Gas

valve

)

279

5095 12

050 50

25

87131

(Liqu

id va

lve)

1000

111

70

155

14221

227

305

341

154

36

Ø28 (Cable port)Ø28 (Cable port)

Ø28 (Cable port)Ø28 (Cable port)

AA

Ø28 (Cable port)

Page 59: Fujitsu 2012 catalog

117116

4-face heat exchanger: Heat exchange efficiency is significantly improved by the introduction of a new 4-face heat exchanger that increases effective surface area.

In multiple outdoor unit installations, the unique front intake design improves airflow into the Heat Exchanger.

High Efficiency

Energy saving technology that boosted operation efficiency

Significantly improved EER/COP

Significantly greater efficiency is realized by the use of a DC twin rotary compressor, inverter technology, and large heat exchanger.

DC Fan motor: Power consumption has been reduced by 25% compared to previous models by using a compact and high performance DC fan motor.

Choice of space saving or energy efficiency combinations

Energy Efficiency Combination

Various Energy Saving FeaturesV series

V-IIseries

V-II series

3.0 3.50 4.0 COPCOPEEREER3.0 3.50 4.0

CoolingCooling HeatingHeatingCooling EER

27% increase!

Surface area

1.7 times!

Heating COP

18% increase!

3.2 3.7

4.074.07 4.374.37* “EER/COP” is the coefficient of performance [ = capacity (kW) ÷ input power (kW) ].*EER/COP values are based on our own testing method.*1. The data refers to a 8HP outdoor unit.

Sine-wave DC inverter control:High efficiency operation is realized by using a sine wave DC inverter control.

DC twin rotary compressor: Significantly greater efficiency is realized by use of a large capacity DC twin rotary compressor with substantially increased refrigerant intake and compression efficiency.

Previousmodel

For 16HP

[ Space saving combination ] [ Energy efficiency combination ]

18%energy saving !

For 24HP

12%energy saving !

For 28HP

10%energy saving !

16HP

12HP 12HP

12HP 8HP 8HP

8HP 8HP

8HP 8HP 8HP

12HP16HP

(Comparison of Average COP)

Smart and cutting edge designExtensive lineup from 8HP to 48HP in 2HP incrementConnectable indoor unit capacity ratio up to 150%

*1 *1

8, 10, 12HP 14, 16HP

Economy operation

Economy operation can be set by remote controller.The temperature setting is offset automatically over a certain period of time.

Room temperature set point limitation

The minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants.

Peak cut operation

Operation capacity can be set in 4 steps for rated capability. The power consumption at peak is cut down and the maximum load is suppressed.

Auto-off timer

Each remote controller is equipped with an OFF timer function that automatically stops operation when a fixed time has elapsed from the start of operation. This prevents waste of energy. (Note: Except simple remote controller)

Cooling Set Temperature

Economy operationControl Temperature

Heating Set Temperature

Economy operationControl Temperature

Set Temp.

MAX. -4°C

MAX. +2°C

Economy operation

UpUp

Economy operation

Set Temp.Down

DownDown

Down

Heating set temp. range

Cooling set temp. range

Heating Cooling

Original Settemp. limitation

Set pointlimitation setting

°C3028262422201816141210

Operation setting (System Controller)

W

Capacity

Time

Settinglevel

Peak cutControl device

Signal input

Page 60: Fujitsu 2012 catalog

119118

Design Versatility

High static pressure of 80Pa

Overall piping length 1,000m              Space saving and compact size

The outdoor unit can have a condenser hood easily connected with a static pressure of 80Pa standard. This allows outdoor units to be installed within plant rooms in high rise buildings.

World’s top class overall piping length of 1,000m allows for application in a wide variety buildings.

Compact size has been achieved by significantly reducing the width of the outdoor units compared to previous models.

Large diameter fan and DC motor has been utilized allowing an external static pressure of 80Pa. This is approximately 2.6 times greater than the previous model.

Installation Example

80Paas standard

60m max.

Pipe length from first separation tube to the farthest indoor unit

50m max.

Height difference between outdoor and indoor units

15m max.

Height difference between indoor and indoor units

150m max.

Actual pipe length

Connectable indoor unit number

up to 48Wide variation of indoor units

12 types, 55 models

Connectable indoor unit capacity

Ratio up to 150%

Installation in extreme temperature conditions is possible due to an increase in operational range.Cooling : -15°C~46°CHeating : -20°C~21°C

Wide operating range

Various combination from 8HP to 48HP with 2HP increments. 12 types, 55 models of indoor units can be selected ranging from 2.2kW to 25kW in capacity. A maximum of 150% indoor unit connectable capacity.

High capacity connection

V series10HP

V-II series10HP

52% reduction

28% reduction

CoolingCooling46°C

21°C

-15°C -15°C -20°C -20°C

Heating

(°C)

-15°C areaOperation possiblein cooling.

-20°C areaOperation possiblein heating.

50

40

30

20

10

0

-10

-20

*1

Note : when indoor unit connected capacity is greater than 100%, individual indoor units will operate at a slightly lower capacity when maximum capacity is required.

*1 Note : When a multiple outdoor unit connection is used, operating range is from -5°C to 46°C in cooling.

Previous model V-II series

Powerful discharge with an external static pressure of 80Pa.

For the outdoor unit stated below : 40m max.

1,000m max.

Total pipe length

For 160HP

16HP(8HP×2)×10=160HP

38.0m2

V series

16HP×10=160HP

16.2m2

V-II series 57% space saving

1,300mm 930mm

V series16HP (8HP x2)

V-II series16HP

2,600mm 1,240mm

Page 61: Fujitsu 2012 catalog

121120

High Reliability Easy Installation

Life-extending operation

DDDDCCC11

AC4

DC2

AACCC55

DC3

DC1

AC4

DC2

AACCC55

DDDCCCCCCCCDDDDDD333333

DC1

AC4

DDDCCC222

AACCC55

DC3

Rotation Rotation

Rotation

Outdoor unit operation rotationThe compressor starting order is rotated so that the running time is shared.

Easily transported

Failure

Indoor unit continuous operationEach indoor unit is controlled individually on the system network. This allows all indoor units to continue to operate unaffected even if an error should occur at any indoor unit’s on the VRF network system.

Corrosion resistant of the heat exchanger has been improved by the introduction of blue fin treatment to the outdoor unit’s heat exchanger.

If one of two compressors malfunctions, it will not affect the operation of the remaining outdoor units.

Outdoor UnitsIf one of compressors fails, backup operation will be performed by the remaining compressors as emergency.

Installation is made easier as the communications wiring can be connected continuously to any component.

The need for a oil equalization pipe as required on the previous model has been removed. The installation costs have been reduced by employing a simple 2 pipe connection

Backup operation

The Web Monitoring system allows you view system operation at all times over the internet ensuring trouble free operation.

The operating VRF network system in the building can be monitored in real time over the Internet.

Remote monitoringAdoption of blue fin heat exchanger

Internetor

Public Telephone Line

Monitoring Side

Indoor unit

Transmission line

Outdoor unit

Simple wiring methodOther wiring method

Simple signal line connection

Design of outdoor unit allows for lifting straps to be used

Web Monitoring Tool

USB adaptor(Field supplied)

Easy access

Expansion of work space

By adopting a L-Shape front panel that can be removed, the work space for installation and service has been significantly expanded by this new design. For multiple installations, work is performed easily and efficiently even in a narrow space.

Automatic addresssetting is performedat outdoor unit

Automatic address setting

Addresses are automaticallydistributed from outdoor unit.

Manual address setting from indoor unit and remote controller is also possible.

3 7 1 0

2 4 5 6

The address of each indoor unit can be automatically set by button switch of outdoor unit.

Up to maximum length 3,600m

Eliminating oil equalization pipe

Easy piping connection

VRF Network System Side

Hydrophilic coating

Cobalt Blue protectionStandard chromate protectionAluminium base material

Blue fin heat exchanger

Note: The inverter compressors start in priority.Rotate operation is alternated by the start / stop timing of the compressors

20% weight reduction(Than Previous model) Note:

In the case of 14HP

Light weight

Easily craned into position using lifting belt hooks

Transporting by forklift

Can be transported in a small elevator

V-II series

Press the pushbutton switch of outdoor unit.

Note: In a multiple refrigerant system installation, Automatic addressing sequence cannot be initiated

Page 62: Fujitsu 2012 catalog

123122

Compressor compartment

Low noise design: Compressor noise has been significantly reduced by shielding the compressor compartment.

Indoor unit: Low noise indoor unit lineup

Auto changeover setting allows for the product to easily switch between cooling and heating modes regardless of the operation mode of other indoor units. This can be done via specific indoor unit with wired remote controller. This ensures comfortable operation all year round.

Switching to cooling and heating mode by specific remote controller in the main room, etc.

A comfortable room condition is maintained during oil recoverymode because the product continues to operate without stopping the cooling or heating operation.

Auto changeover function

Non-stop oil recovery operation

Emergency alarm can be received by indoor, outdoor units or Touch Panel Controller when they received it, all units will be stopped.

Maintenance of electrical components, valves, and compressor parts from the front is possible.

Split front panel allows for maintenance from top or bottom of the outdoor unit

Easy-to-read 7-segment LED display which explains operational and trouble status

Note: In case of received Emergency alarm byIndoor/outdoor unit: All units connected within same refrigerant system will be stopped. Touch Panel Controller: all unit connected within VRF network system with Touch Panel Controller will be stopped.

Non-stop operation: When servicing a specific indoor unit, maintenance can be performed even without turning off the other indoor units.

Emergency stop function

Continuous operation during maintenance

ON OFF ON ON ON ON

Compact Duct

Slim Duct

Low Static Pressure Duct Compact Wall Mounted

Compact Cassette

Air conditioning load factor

Capacity

Operating sound

time

100%

58dB

0

0

Heat load

down

Quiet priority low noise mode

Quiet priority setting

Capacity priority low noise mode

time

100%

58dB

0

0Reset automatically

Alternatedautomatically

Capacity priority setting

Heat loadHeat loadHeat load

Previous model V-II series (Heating operation)

Time

ON

OFF

Operation stopped at oil recovery

Time

ON

Non-stop oil recovery operation

Wired Remote Controller Simple Remote ControllerError status can be checked easily via the indoor unit wired controller

Touch Panel Controller

Emergencystop function

Emergencystop function

Emergencystop function

vavalvalvalvalvalvvvevesfro

Comfort and Convenience

Quiet operation

Low noise mode:Two low noise modes can be selected automatically by quiet priority setting and capacity priority setting depending on the usage environment and outside temperature load.

Easy Service & Maintenance

Design for easy service and maintenance

Inspection and replacement of main parts is easier due to innovative construction and an LED operational display.

An error code is displayed on a liquid crystal screen.

Movable PCB panel that allows for easier maintenance work behind the PCB

Consolidated electrical components make maintenance easy

SU MO TU WE TH FR SA

Faulty unit number(Remote controller address)

Error code

Remote controller address

Error code

Page 63: Fujitsu 2012 catalog

125124

Outdoor units lineup Outdoor units dimensions

Dimensions (Unit : mm)

8,10,12HP: AJYA72LALH / AJYA90LALH / AJY108LALH

14,16HP: AJY126LALH / AJY144LALH

8-12×17 (Hole)

1690

652.5

765

530 (Bolt pitch)80690 (Bolt pitch)

732 (

Bolt p

itch)

8-12×7 (Hole)

1690

765

732 (

Bolt p

itch)

1000 (Bolt pitch)840 (Bolt pitch)80

ø43.7

ø22.2Transmission cable port

Power supply cable portø61.3431

80

190

82

42

Pipe port

100

5373

7595

179

ø43.7

ø22.2

ø22.2

125

Pipe port

Power supply cable port

Transmission cable port

Transmission cable port

10

A

AB C

B Bottom side knockout positionCFront side knockout position Left side knockout positionTop view

Back view

Back view

Power supply cable port

Space saving combination

Energy efficiency combination

28.0kW (10HP)

44.8kW (16HP)

84.8kW (30HP) 89.8kW (32HP) 95.9kW (34HP) 102.4kW (36HP) 113.5kW (40HP)

120.0kW (42HP) 125.0kW (44HP)

67.2kW (24HP) 72.8kW (26HP) 78.3kW (28HP)62.4kW (22HP)

22.4kW (8HP)

•Combinations other than the followings are not recommended.

33.5kW (12HP) 40.0kW (14HP) 45.0kW (16HP)

50.4kW (18HP) 55.9kW (20HP) 61.5kW (22HP) 67.0kW (24HP) 73.5kW (26HP)

78.5kW (28HP) 85.0kW (30HP) 90.0kW (32HP) 95.0kW (34HP) 100.5kW (36HP)

107.0kW (38HP) 112.0kW (40HP) 118.5kW (42HP) 123.5kW (44HP) 130.0kW (46HP)

135.0kW (48HP)

AJY198LALHHUNIT : AJY126/A72LALH

AJY216LALHHUNIT : AJYA72/A72/A72LALH

AJY234LALHHUNIT : AJYA90/A72/A72LALH

AJY252LALHHUNIT : AJY108/A72/A72LALH

AJY144LALHHUNIT : AJYA72/A72LALH

AJY288LALHHUNIT : AJY108/108/A72LALH

AJY306LALHHUNIT : AJY126/108/A72LALH

AJY324LALHHUNIT : AJY126/126/A72LALH

AJY360LALHHUNIT : AJY126/126/108LALH

AJY270LALHHUNIT : AJY126/A72/A72LALH

AJY396LALHHUNIT : AJY144/126/126LALH

AJY378LALHHUNIT : AJY126/126/126LALH

AJYA90LALHUNIT : AJYA90LALH

AJY108LALHUNIT : AJY108LALH

AJY126LALHUNIT : AJY126LALH

AJY144LALHUNIT : AJY144LALH

AJYA72LALHUNIT : AJYA72LALH

AJY180LALHUNIT : AJY108/A72LALH

AJY198LALHUNIT : AJY108/A90LALH

AJY216LALHUNIT : AJY108/108LALH

AJY234LALHUNIT : AJY126/108LALH

AJY162LALHUNIT : AJYA90/A72LALH

AJY270LALHUNIT : AJY144/126LALH

AJY288LALHUNIT : AJY144/144LALH

AJY306LALHUNIT : AJY108/108/A90LALH

AJY324LALHUNIT : AJY108/108/108LALH

AJY252LALHUNIT : AJY144/108LALH

AJY360LALHUNIT : AJY144/108/108LALH

AJY378LALHUNIT : AJY144/126/108LALH

AJY396LALHUNIT : AJY144/144/108LALH

AJY414LALHUNIT : AJY144/144/126LALH

AJY342LALHUNIT : AJY126/108/108LALH

AJY432LALHUNIT : AJY144/144/144LALH

930

1240

Page 64: Fujitsu 2012 catalog

127126

Outdoor units specifications

Energy Efficiency Combination

HPRating Capacity range

Space Saving Combination

m3/h

kW

kW

mm

mmmmmm

˚C

W/W

dB(A)

kW

Capacity

Power source

PakW

kgkg

CoolingHeatingCoolingHeatingCoolingHeatingHighCoolingHeating

Cooling

Unit 1Unit 2Unit 3

Model name

Maximum Connectable Indoor Unit*1

Indoor unit connectable capacity

Input power

EERCOPAir flow rate

Dimensions

WeightRefrigerant chargeConnection pipe diameterOperation range

Sound pressure level*2

Maximum external static pressureCompressor motor outputHeat exchanger fin

HeightWidthDepth

LiquidGasCoolingHeating

8

22.425.05.515.724.074.37

11,1005658803.9

Blue fin1,690930 76522011.2

12.7022.20

-15 to 46-20 to 21

1511.2-33.6

10

28.031.57.737.83 3.62 4.02

11,1005859803.9

Blue fin1,690 93076522011.2

12.7022.20

-15 to 46-20 to 21

1614.0-42.0

12

33.537.59.62 9.28 3.484.04

11,100586080

3.9 + 4.5Blue fin1,690 93076527511.8

12.7028.58

-15 to 46-20 to 21

1716.8-50.2

14

40.045.011.5311.453.473.93

13,000606180

3.9 + 4.5Blue fin1,690 1,24076529611.8

12.7028.58

-15 to 46-20 to 21

2120.0-60.0

16

45.050.0

14.1712.603.183.97

13,000616180

3.9 + 4.5Blue fin1,690 1,24076529611.8

12.7028.58

-15 to 46-20 to 21

2422.4-67.2

18

50.456.5

13.2413.55 3.81 4.17

11,100 x 2606280

3.9 x 2Blue fin1,690 930 x 2

765220 + 22011.2 x 215.8828.58

-5 to 46-20 to 21

3225.2-75.6

20

55.962.5

15.13 15.00 3.694.17

11,100 x 2606280

3.9 x 2 + 4.5Blue fin1,690

930 x 2765

275 + 22011.8 + 11.2

15.8828.58

-5 to 46-20 to 21

3228.0-83.9

22

61.569.0

17.35 17.11 3.54 4.03

11,100 x 2616380

3.9 x 2 + 4.5Blue fin1,690

930 x 2765

275 + 22011.8 + 11.2

15.8834.92

-5 to 46-20 to 21

3230.8-92.3

24

67.075.0

19.24 18.56 3.484.04

11,100 x 2616380

3.9 x 2 + 4.5 x 2Blue fin1,690

930 x 2765

275 + 27511.8 x 215.8834.92

-5 to 46-20 to 21

3533.5-100.5

36

100.5112.528.86 27.84 3.484.04

11,100 x 3636580

3.9 x 3 + 4.5 x 3Blue fin1,690 930 x 3

765275 + 275 + 275

11.8 x 319.0541.27

-5 to 46-20 to 21

4850.3-150.8

34

95.0106.526.97 26.39 3.524.04

11,100 x 3636480

3.9 x 3 + 4.5 x 2Blue fin1,690 930 x 3

765275 + 275 + 22011.8 x 2 + 11.2

19.0534.92

-5 to 46-20 to 21

4847.5-142.5

32

90.0100.028.3425.203.183.97

13,000 x 2646480

3.9 x 2 + 4.5 x 2Blue fin1,690

1,240 x 2 765

296 + 29611.8 x 219.0534.92

-5 to 46-20 to 21

4845.0-135.0

30

85.095.025.7024.053.313.95

13,000 x 2646480

3.9 x 2 + 4.5 x 2Blue fin1,690

1,240 x 2765

296 + 29611.8 x 219.0534.92

-5 to 46-20 to 21

4542.5-127.5

28

78.587.5

23.79 21.88 3.304.00

13,000 + 11,100636480

3.9 x 2 + 4.5 x 2Blue fin1,690

930 + 1,240765

296 + 27511.8 x 215.8834.92

-5 to 46-20 to 21

4239.3-117.8

26

73.582.5

21.15 20.73 3.483.98

13,000 + 11,100626480

3.9 x 2 + 4.5 x 2Blue fin1,690

930 + 1,240765

296 + 27511.8 x 215.8834.92

-5 to 46-20 to 21

3936.8-110.3

38

107.0120.030.77 30.01 3.484.00

13,000 + 11,100 × 2646580

3.9 x 3 + 4.5 x 3Blue fin1,690

930 x 2 + 1,240765

296 + 275 + 27511.8 x 319.0541.27

-5 to 46-20 to 21

4853.5-160.5

40

112.0125.033.41 31.16 3.354.01

13,000 + 11,100 × 2646580

3.9 x 3 + 4.5 x 3Blue fin1,690

930 x 2 + 1,240765

296 + 275 + 27511.8 x 319.0541.27

-5 to 46-20 to 21

4856.0-168.0

42

118.5132.535.32 33.33 3.363.98

13,000 × 2 + 11,100656580

3.9 x 3 + 4.5 x 3Blue fin1,690

930 + 1,240 x 2765

296 + 296 + 27511.8 x 319.0541.27

-5 to 46-20 to 21

4859.3-177.8

44

123.5137.537.96 34.48 3.253.99

13,000 × 2 + 11,100656580

3.9 x 3 + 4.5 x 3Blue fin1,690

930 + 1,240 x 2765

296 + 296 + 27511.8 x 319.0541.27

-5 to 46-20 to 21

4861.8-185.3

46

130.0145.039.8736.653.263.96

13,000 x 3656680

3.9 x 3 + 4.5 x 3Blue fin1,690

1,240 x 3765

296 + 296 + 29611.8 x 319.0541.27

-5 to 46-20 to 21

4865.0-195.0

48

135.0150.042.5137.803.183.97

13,000 x 3666680

3.9 x 3 + 4.5 x 3Blue fin1,690

1,240 x 3765

296 + 296 + 29611.8 x 319.0541.27

-5 to 46-20 to 21

4867.5-202.5

AJYA72LALHAJYA72LALH

AJYA90LALHAJYA90LALH

AJY108LALHAJY108LALH

AJY126LALHAJY126LALH

AJY144LALHAJY144LALH

AJY162LALHAJYA90LALHAJYA72LALH

AJY180LALHAJY108LALHAJYA72LALH

AJY198LALHAJY108LALHAJYA90LALH

AJY216LALHAJY108LALHAJY108LALH

AJY324LALHAJY108LALHAJY108LALHAJY108LALH

AJY306LALHAJY108LALHAJY108LALHAJYA90LALH

AJY288LALHAJY144LALHAJY144LALH

AJY270LALHAJY144LALHAJY126LALH

AJY252LALHAJY144LALHAJY108LALH

AJY234LALHAJY126LALHAJY108LALH

AJY342LALHAJY126LALHAJY108LALHAJY108LALH

AJY360LALHAJY144LALHAJY108LALHAJY108LALH

AJY378LALHAJY144LALHAJY126LALHAJY108LALH

AJY396LALHAJY144LALHAJY144LALHAJY108LALH

AJY414LALHAJY144LALHAJY144LALHAJY126LALH

AJY432LALHAJY144LALHAJY144LALHAJY144LALH

HPRating Capacity range

m3/h

kW

kW

mm

mmmmmm

˚C

W/W

dB(A)

kW

Capacity

Power source

PakW

kgkg

CoolingHeatingCoolingHeatingCoolingHeatingHighCoolingHeating

Cooling

Unit 1Unit 2Unit 3

Model name

Maximum Connectable Indoor Unit*1

Indoor unit connectable capacity

Input power

EERCOPAir flow rate

Dimensions

WeightRefrigerant chargeConnection pipe diameterOperation range

Sound pressure level*2

Maximum external static pressureCompressor motor outputHeat exchanger fin

HeightWidthDepth

LiquidGasCoolingHeating

16

44.850.011.0211.444.074.37

11,100 x 2595980

3.9 x 2Blue fin1,690 930 x 2

765220 + 22011.2 x 212.7028.58

-5 to 46-20 to 21

3022.4-67.2

22

62.470.017.0417.173.664.08

13,000 + 11,100616280

3.9 x 2 + 4.5Blue fin1,690

930 + 1,240765

296 + 22011.8 + 11.2

15.8834.92

-5 to 46-20 to 21

3331.2-93.6

24

67.275.0

16.5317.164.074.37

11,100 x 3616180

3.9 x 3Blue fin1,690

930 x 3765

220 + 220 + 22011.2 x 315.8834.92

-5 to 46-20 to 21

3633.6-100.8

26

72.881.5

18.7519.27 3.88 4.23

11,100 x 3626280

3.9 x 3Blue fin1,690

930 x 3765

220 + 220 + 22011.2 x 315.8834.92

-5 to 46-20 to 21

3936.4-109.2

28

78.387.5

20.64 20.72 3.794.22

11,100 x 3626380

3.9 x 3 + 4.5Blue fin1,690

930 x 3765

275 + 220 + 22011.8 + 11.2 x 2

15.8834.92

-5 to 46-20 to 21

4239.2-117.4

30

84.895.022.5522.893.764.15

13,000 + 11,000 x 2636380

3.9 x 3 + 4.5Blue fin1,690

930 x 2 + 1,240765

296 + 220 + 22011.8 + 11.2 x 2

19.0534.92

-5 to 46-20 to 21

4542.4-127.2

44

125.0140.037.2335.503.363.94

13,000 x 3656680

3.9 x 3 + 4.5 x 3Blue fin1,690

1,240 x 3765

296 + 296 + 29611.8 x 319.0541.27

-5 to 46-20 to 21

4862.5-187.5

42

120.0135.034.5934.353.473.93

13,000 x 3656680

3.9 x 3 + 4.5 x 3Blue fin1,690

1,240 x 3765

296 + 296 + 29611.8 x 319.0541.27

-5 to 46-20 to 21

4860.0-180.0

40

113.5127.532.68 32.18 3.473.96

13,000 x 2 + 11,100646580

3.9 x 3 + 4.5 x 3Blue fin1,690

930 + 1,240 x 2765

296 + 296 + 27511.8 x 319.0541.27

-5 to 46-20 to 21

4856.8-170.2

36

102.4115.028.5728.623.584.02

13,000 x 2 + 11,100646580

3.9 x 3 + 4.5 x 2Blue fin1,690

930 + 1,240 x 2765

296 + 296 + 22011.8 x 2 + 11.2

19.0541.27

-5 to 46-20 to 21

4851.2-153.6

34

95.9107.526.66 26.45 3.604.06

13,000 + 11,100 x 2636480

3.9 x 3 + 4.5 x 2Blue fin1,690

930 x 2 + 1,240765

296 + 275 + 22011.8 x 2 + 11.2

19.0534.92

-5 to 46-20 to 21

4848.0-143.8

32

89.4 100.0 24.75 24.28 3.61 4.12

11,100 x 3626480

3.9 × 3 + 4.5 × 2Blue fin1,690

930 × 3765

275 + 275 + 22011.8 × 2 + 11.2

19.0534.92

-5 to 46-20 to 21

4844.7-134.1

AJY144LALHHAJYA72LALHAJYA72LALH

AJY198LALHHAJY126LALHAJYA72LALH

AJY216LALHHAJYA72LALHAJYA72LALHAJYA72LALH

AJY234LALHHAJYA90LALHAJYA72LALHAJYA72LALH

AJY252LALHHAJY108LALHAJYA72LALHAJYA72LALH

AJY270LALHHAJY126LALHAJYA72LALHAJYA72LALH

AJY396LALHHAJY144LALHAJY126LALHAJY126LALH

AJY378LALHHAJY126LALHAJY126LALHAJY126LALH

AJY360LALHHAJY126LALHAJY126LALHAJY108LALH

AJY324LALHHAJY126LALHAJY126LALHAJYA72LALH

AJY306LALHHAJY126LALHAJY108LALHAJYA72LALH

AJY288LALHHAJY108LALHAJY108LALHAJYA72LALH

3-phase 4 wire, 400 V, 50Hz 3-phase 4 wire, 400 V, 50Hz

3-phase 4 wire, 400 V, 50Hz3-phase 4 wire, 400 V, 50Hz

Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.

Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.When cooling operation will be conducted at outdoor air temperature below -5°C, the outdoor unit must be installed in a position that is higher than or equal to those of indoor units.

*1 Minimum connectable indoor unit number is 2. However ARXC72 and ARXC90 can be used signal connection.*2 The noise value is the value when measured in an anechoic room.

When measured in the actual installed state, surrounding noise and reflections are received and the measured value is usually larger than the indicated value.

Page 65: Fujitsu 2012 catalog

129128

&

Indoor units lineup

Compact Cassette

Cassette

Compact Duct

Slim Duct(Drain pump internal)

Low Static Pressure Duct

High Static Pressure Duct

Duct

Floor / Ceiling

Ceiling

2.20Capacity range (kW)Model code

2.80 3.60 4.50 5.60 7.10 11.29.00 12.5 14.0 18.0 22.4 25.07 9 12 14 18 24 3630 45 54 60 72 90

AUXB07LALH AUXB09LALH AUXB12LALH AUXB14LALH AUXB18LALH

AUXD18LALH

ARXB07LALH ARXB09LALH ARXB12LALH ARXB14LALH

ASYE07LACH ASYE09LACH ASYE12LACH ASYE14LACH

ARXB18LALH

ASYA18LACH

ABYA12LBTH ABYA14LBTH ABYA18LBTH ABYA24LBTH

AUXD24LALH

AUXB24LALH

AUXA45LALHAUXA36LALH AUXA54LALH

ARXB30LATH

AUXA30LALH

ARXB24LATH ARXB36LATH ARXB45LATH

ARXA30LATHARXA24LATH ARXA36LATH ARXA45LATH

ARXC36LATH ARXC45LATH ARXC60LATH* ARXC72LATH* ARXC90LATH*

ABYA30LBTH ABYA36LBTH ABYA45LBTH ABYA54LBTH

Compact Wall Mounted(EEV internal)

Wall Mounted

Compact Wall Mounted(EEV external)

With this model, connection of EV kit is necessary.

ASYA07LACH ASYA09LACH ASYA12LACH ASYA14LACH

ARXD07LATH ARXD09LATH ARXD12LATH ARXD14LATH ARXD18LATH ARXD24LATH

ASYA30LACHASYA24LACH

*: ARXC60/72/90LATH can be connected to V-II series only.

Page 66: Fujitsu 2012 catalog

131130

&

Indoor units specifications

Compact Cassette Compact DuctLow Static Duct & Duct

Cassette

Model name

Slim Duct(Drain pump internal)

Model name

Model name

Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].

Model name

Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.

*: ARXC60/72/90LATH can be connected to V-II series only.

Model name

Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].

High Static Pressure Duct

2.22.846

370310280

0 to 5025292624

2.22.844

550490440

0 to 9025282522

2.83.250

600550480

0 to 9025292624

3.64.054

600510450

0 to 9025302724

4.55.092

800710610

0 to 9025343228

5.66.383

940840750

0 to 9025343228

198 x 900 x 62023

7.18.0122

1,3301,2401,100

0 to 5025353229

198 x 1,100 x 62027

ARXB07LALH

ARXB09LALH

ARXB12LALH

ARXB18LALH

ARXB14LALH

CoolingHeating

HighMedLow

HighMedLow

Liquid (Flare)Gas (Flare)

Drain

2.83.255

440370340

0 to 5025312927

4.55.090

800750700

0 to 5025333230

217 x 953 x 59525

3.64.063

590500450

0 to 5025302825

ø25 (I.D.) ; ø32 (O.D.)

kW

W

m3/ h

Pa

dB(A)

mm

mm

kg

Power source

Capacity

Input power

Airflow rate

Static pressure rangeStandard static pressure

Sound pressure level

Dimensions (H x W x D)Weight

Connectionpipe diameter

CoolingHeating

HighMedLow

HighMedLow

Liquid (Flare)Gas (Flare)

Drain

kW

W

m3/ h

Pa

dB(A)

mm

mm

kg

Power source

Capacity

Input power

Airflow rate

Static pressure rangeStandard static pressure

Sound pressure level

Dimensions (H x W x D)Weight

Connectionpipe diameter

7.18.0145

1,100920810

0 to 8040312725

43

ARXB24LATH

ARXB30LATH

ARXB36LATH

ARXA24LATH

ARXA30LATH

ARXA36LATH

ARXA45LATH

ARXB45LATH

9.010.0198

1,4101,2801,150

0 to 8050343229

12.514.0338

1,9701,7901,6700 to 80

60413836

7.18.0190

1,2801,2101,130

30 to 150100383634

43

9.010.0188

1,2801,2101,130

30 to 150100403836

11.212.5312

1,7201,6701,600

30 to 150100434139

45

12.514.0 312

1,7201,6701,600

30 to 150100434139

11.212.5253

1,7101,6001,470

0 to 8050373533

45ø9.52

ø25 (I.D.) ;ø32 (O.D.)

ø22 (I.D.) ;ø26 (O.D.)

230V~ , 50Hz

1918

270 x 1,135 x 700 270 x 1,135 x 700

ø9.52

ø25 (I.D.) ;ø32 (O.D.)ø15.88 ø15.88ø19.05 ø19.05

230V~ , 50Hz

217 x 663 x 59518

ø12.70ø6.35

CoolingHeating

HighMedLowHighMedLow

Liquid (Flare)Gas (Flare)

Drain

kW

W

m3/ h

dB(A)

mm

mm

mm

kg

kg

Power source

Capacity

Input power

Airflow rate

Sound pressure level

Dimensions (H x W x D)Weight

Connectionpipe diameter

Decoration Panel(option)

Decoration Panel(option)

CoolingHeating

HighMedLow

HighMedLow

LiquidGasDrain

kW

W

m3/ h

Pa

dB(A)

mm

mm

kg

Power source

Capacity

Input power

Airflow rate

Static pressure rangeStandard static pressure

Sound pressure level

Dimensions (H x W x D)Weight

Connectionpipe diameter

11.2 12.5 405

2,6001,9501,450

100 to 200100453832

45

12.514.0427

3,5003,0002,460

100 to 250100494542

400 x 1,050 x 500

ø9.52 (Flare)ø19.05 (Flare)

22.425.0

1,1103,9003,3003,000

50 to 300260514845

82

230V~ , 50Hz18.020.0427

3,5003,0002,460

100 to 250100494542

ø25 (I.D.) ; ø32 (O.D.)

25.028.0

1,2504,3004,0003,500

100 to 300250535149

85

ARXC36LATH

ARXD07LATH ARXD09LATH ARXD12LATH ARXD14LATH ARXD18LATH ARXD24LATH

ARXC45LATH ARXC60LATH* ARXC72LATH* ARXC90LATH*

47ø12.70 (Brazing)ø22.22(Brazing)

450 x 1,550 x 700

2.22.825

540450350343025

AUXB07LALH AUXB09LALH AUXB12LALH AUXB18LALHAUXB14LALH

2.83.225550450350353025

4.55.035

680590390383427

5.66.336710580400413527

7.18.084

1,030830450504430

3.64.129600530390373427

15ø6.35

ø12.70

AUXB24LALH

245 x 570 x 570

ø25 (I.D) ;ø32 (O.D.)UTG-UFYC-W50 x 700 x 700

2.6

17ø9.52ø15.88

230V~ , 50Hz

Model nameDimensions (H x W x D)Weight

CoolingHeating

HighMedLowHighMedLow

Liquid (Flare)Gas (Flare)

Drain

kW

W

m3/ h

dB(A)

mm

mm

mm

kg

kg

Power source

Capacity

Input power

Airflow rate

Sound pressure level

Dimensions (H x W x D)Weight

Connectionpipe diameter

230V~ , 50Hz

Model nameDimensions (H x W x D)Weight

5.66.339

1,150940870363029

7.18.046

1,2801,040870383329

9.010.059

1,6001,3001,100

403833

11.212.580

1,8001,3001,100

443833

12.514.099

1,9001,3701,100

463933

14.016.0119

2,0001,3701,100

473933

AUXD18LALH AUXD24LALH AUXA30LALH AUXA45LALHAUXA36LALH AUXA54LALH

246 x 840 x 84023

ø15.88

288 x 840 x 84027

ø19.05ø9.52

ø25 (I.D.) ; ø32 (O.D.)UTG-UGYA-W50 x 950 x 950

5.5

5.66.396

890810730

0 to 5025363430

ø9.52ø15.88

ø9.52ø15.88

ø6.35ø12.70

198 x 700 x 620

Page 67: Fujitsu 2012 catalog

133132

&

Indoor units specifications

Floor / Ceiling Compact Wall Mounted

Ceiling

Model name

Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].

Model name

Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].

Model name

Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].

ABYA12LBTH ABYA14LBTH ABYA18LBTH ABYA24LBTH

Model name

Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].

ABYA30LBTH ABYA36LBTH ABYA45LBTH ABYA54LBTH

230V~ , 50Hz

ASYA18LACH ASYA24LACH ASYA30LACH

Wall Mounted

2.22.816

490450370353327

2.83.216

500450370363327

CoolingHeating

HighMedLowHighMedLow

Liquid (Flare)Gas (Flare)

Drain

kW

W

m3/ h

dB(A)

mm

mm

kg

Power source

Capacity

Input power

Airflow rate

Sound pressure level

Dimensions (H x W x D)Weight

EV Kit (option)

Connectionpipe diameter

CoolingHeating

HighMedLowHighMedLowNetNet

Liquid (Flare)Gas (Flare)

Drain

kW

W

m3/ h

dB(A)

mm

mm

kg

Power source

Capacity

Input power

Airflow rate

Sound pressure level

Dimensions (H x W x D)Weight

Connectionpipe diameter

CoolingHeating

HighMedLowHighMedLow

Liquid (Flare)Gas (Flare)

Drain

kW

W

m3/ h

dB(A)

mm

mm

kg

Power source

Capacity

Input power

Airflow rate

Sound pressure level

Dimensions (H x W x D)Weight

Connectionpipe diameter

3.64.030660570490363228

25 27

4.55.042780640550403634

5.66.374

1,000720580463935

7.18.099

1,000820680474237

230V~ , 50Hz

199 x 990 x 655

ø25 (I.D.) ; ø32 (O.D.)

ø6.35ø12.70

ø9.52ø15.88

CoolingHeating

HighMedLowHighMedLow

Liquid (Flare)Gas (Flare)

Drain

kW

W

m3/ h

dB(A)

mm

mm

kg

Power source

Capacity

Input power

Airflow rate

Sound pressure level

Dimensions (H x W x D)Weight

Connectionpipe diameter

9.010.066

1,6301,3701,140

423833

47ø9.52

ø15.88

11.212.585

1,6901,4001,170

453834

12.514.0131

2,0101,6001,230

484235

48ø9.52

ø19.05

14.016.0180

2,2701,7801,280

514536

230V~ , 50Hz

240 x 1,660 x 700

ø25 (I.D.) ; ø32 (O.D.)

4.55.030

670490420443732

2.22.815

490450370343226

2.83.216

500450370353226

3.64.120

560480420383430

4.55.028

680490420433530

3.64.119

560480420393531

ASYA07LACH ASYA09LACH ASYA12LACH ASYA14LACH ASYE07LACH ASYE09LACH ASYE12LACH ASYE14LACH

230V~ , 50Hz 230V~ , 50Hz

275 x 790 x 2159

ø6.35ø12.70

ø13.8(I.D.) ; ø15.8-ø16.7(O.D.)-

275 x 790 x 2159

ø6.35ø12.70

ø13.8(I.D.) ; ø15.8-ø16.7(O.D.)UTR-EV09XB UTR-EV14XB

5.66.335

840770690413935

7.18.064

1,100910730484335

320 x 998 x 22815

ø9.52ø15.88

ø12 (I.D.) ; ø16 (O.D.)

8.09.091

1,240980770524535

Page 68: Fujitsu 2012 catalog

135134

Type VRF

Wired Remote Controller

Individualcontrolsystem

Simple Remote Controller

Simple Remote Controller(Without operation mode)

Wireless Remote Controller

IR Receiver Unit

IR Receiver Kit

Group Remote Controller

Centralizedcontrolsystem

Adaptor & Convertor

Service &Maintenance

Central Remote Controller

Central Remote Controller

Touch panel Controller

System Controller

Network Convertor

Network Convertor for LONWORKS®

BACnet® Gateway

Service Tool

Signal Amplifier

Web Monitoring Tool

SU MO TU WE TH FR SA

7

3 126 9 15 18 21

External Switch Controller

Max. controllable remote controller groups

Max. controllable indoor units

Max. controllable groups

On / Off

Operating mode setting

Fan speed setting

Room temp. setting

Room temp. set point limitation

Test operation

Up/down air direction flap setting

Right/left air direction flap setting

Group setting

RC prohibition

Anti freeze setting

Economy mode setting

Failure

Defrosting

Current time

Day of week

R.C. prohibition

Cooling/heating priority

Address display

Schedule timer

On/off timer

Sleep timer

Program timer

Day off

Min. unit of timer setting(Minutes)

Status monitoring system

Electricity charge calculation

Error history

Emergency stop

Control via internet

E-mail notification for malfunction

Type

Model name

*1 "Operation mode" setting is not available for this model.*2 This function is available only through external input. control.

Period

On/off per day

On/off per week

Individual control Centralized control

Air

cond

ition

ing

cont

rol f

unct

ion

Dis

play

Tim

erC

ontr

ol

1

16

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

SimpleRemote

Controller

*1

UTB-YRAUTY-RHKY

UTB-YPBUTY-RSKY

1

16

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

SimpleRemote

Controller

WiredRemote

Controller

UTB-YUBUTY-RNKY

1

16

-

-

-

-

-

Week

4

28

-

-

30

-

-

-

-

-

SU MO TU WE TH FR SA

7

3 126 9 15 18 21

8

96

-

-

-

-

-

-

-

-

-

-

-

Week

4

28

-

-

-

-

10

-

-

-

-

-

100

100

16

-

-

-

-

-

-

-

-

-

-

-

Week

20

140

-

-

-

-

10

-

-

-

-

-

-

400

400

64

-

Week

4

28

-

-

10

-

-

-

-

-

GroupRemote

Controller

UTB-YDBUTY-CGGY

1

16

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

5

-

-

-

-

-

-

WirelessRemote

Controller

UTB-YVBUTY-LNHY

*2*2

TouchPanel

Controller

UTY-DTGY

400

400

400

Year

20

140

-

-

-

10

-

-

-

SystemController(Software)

UTY-APGX

1600

1600

1600

-

Year

72

504

-

-

-

10

-

UTY-RSKY

UTY-LNHY

UTY-LRHYB1

-

UTY-DTGY

UTY-CGGY

UTY-DCGY

UTY-VGGXZ1

UTY-VLGX

UTY-ABGX

UTY-ASGX

UTY-RNKY

J-II & V-II

UTY-VSGX

UTY-AMGX

UTY-TEKX

UTY-APGXUTY-PEGX

UTY-RHKY

UTB-YWC

UTB-YPB

UTB-YVB

-

UTB-YCA

-

UTB-YDB

UTR-YRDA

UTR-YLLA

UTY-ABGX

UTY-ASGX

UTB-YUB

UTY-VSGX

UTY-AMGX

UTR-YESAUTY-TEKX

UTY-APGX

UTB-YRA

S

UTB-YWA

-

CentralRemote

Controller

UTY-DCGY

CentralRemote

Controller

UTB-YCA

Control Systems Lineup Comparison table of Controllers

Page 69: Fujitsu 2012 catalog

137136

System diagram

SystemAir ConditioningCentral Control

Air ConditioningIndividual Control

Outdoor unit

Indoor unit

Signal AmplifierUTY-VSGX

General-purpose Building Control Computer

BuildingManagement

Service Tool (Software)UTY-ASGX

USBAdaptor

(Field supplied)

USBAdaptor

(Field supplied)

*2*2

NetworkConvertor

UTR-YRDA

Card-key

(Field supplied)

For single splitNetworkConvertorUTR-YRDA

Connectable tovarious sized BMS/BAS

Web Monitoring VRF System Side(Software)UTY-AMGX

Internet orPublic Telephone Line

(Monitoring side)

*1. BMS/BAS: Building Management System/Building Automation System*2. USB Adaptor is U10 USB Network interface of Echelon® corporation.

or

IR Receiver UnitUTB-YWA

Wired Remote ControllerUTB-YUB

External Switch ControllerUTR-YESAUTY-TEKX

Network Convertor for LONWORKS®UTR-YLLA

System Controller (Software)UTY-APGX

Wireless Remote ControllerUTB-YVB

Simple Remote ControllerUTB-YPB

Simple Remote ControllerUTB-YRA Without operation mode

It supports every user's needs by offering a variety of control systems available, such as individual control, central control and building management system control options

Wiring system•Wiring construction of the control system is made of power source wiring, transmission wiring and remote controller wiring.•Total wiring length (total length of transmission line) can be extended up to 2000m (by using signal amplifiers).

USBAdaptor

(Field supplied)

*2

USBAdaptor

(Field supplied)

*2

*1

BACnet ® GatewayUTY-ABGX

Group Remote ControllerUTB-YDB

Central Remote ControllerUTB-YCA

Transmission line (VRF Network)Remote controller lineUSB cable

LONWORKS® NetworkEthernetSignal line(Single split system)Group Remote Controller line

Transmission line

Remote Controller line

Group Remote Controller line

Signal line (single system)

USB cable

Ethernet

LONWORKS® Network

USBAdaptor

USB Adaptor

USB Adaptor (Field supplied)

Network Convertor

Network Convertor Network Convertor

Signal Amplifier

Web Monitoring Tool Trouble free operation at all times by remote monitoring system.

Service ToolExtensive monitoring and analysis functions for installation and maintenance.

2 Remote Controllers Indoor unit can be controlled from both remote controllers.

External Switch ControllerIndoor units can be controlled by combining with Card-key switch such as hotel room.

System without remote controllerTogether with Touch Panel Controller, it is possible to build non remote controller system.

IR Receiver UnitDuct type indoor unit can be controlled with Wireless Remote Controller.

Remote controller lineMaximum 16 units can be controlled

Group Remote ControllerMaximum 8 remote controller groups can be controlled

Central Remote ControllerMaximum 16 units can be connected.One central remote controller can control up to 64 groups / 400 indoor units.

System Controller•Maximum 1600 indoor units can be controlled. •Air conditioning control •Operation monitoring •Status monitoring system•Electricity charge calculation

Service Tool

Big multi system

Card key

Single system

Outdoorunit

Indoor unit(Cassette)

Indoor unit(Duct)

SystemController

Central remoteController

GroupRemote Controller

SimpleRemote Controller

SimpleRemote Controller

WirelessRemote Controller

WiredRemote Controller

External SwitchController

IR Receiverunit

BACnet® GatewayBACnet®

LONWORKS®

BACnet®

BACnet® Operator Workstation (B-OWS)

Combination ofindividual remote controller

Wired, Simple and Wireless Remote Controllers can be used jointly.

Internetor

Public Telephone Line

Transmission lineline is non-polar 2-conductor.

LONWORKS®Network

Building Management System

2,000m

Max. transmissionline length

(Monitoring side)

(Monitoring side)

(Monitoring side)

Web Monitoring Tool

(VRF system side)

USB Adaptor

Signal Amplifier

NetworkConvertor

Control Systems for series

Page 70: Fujitsu 2012 catalog

139138

System diagram

SystemAir ConditioningCentral Control

Air ConditioningIndividual Control

Outdoor unit

Indoor unit

Signal AmplifierUTY-VSGX

General-purpose Building Control Computer

BuildingManagement

Service Tool (Software)UTY-ASGX

USBAdaptor

NetworkConvertor

UTY-VGGXZ1

Card-key

(Field supplied)

(Field supplied)

For single split

Connectable tovarious sized BMS/BAS

NetworkConvertorUTY-VGGX

Web Monitoring Tool (Software)UTY-AMGX

(VRF system side)

Internet orPublic Telephone Line

(Monitoring side)

or

IR Receiver UnitUTB-YWBUTB-YWC

Remote/Monitoring side

Internet or PublicTelephone Line

IR Receiver KitUTY-LRHYB1

Wired Remote ControllerUTY-RNKY

External Switch ControllerUTY-TEKX

Network Convertor(BMS / LONWORKS®)UTY-VLGX

System Controller (Software)UTY-APGX

Simple Remote ControllerUTY-RSKY

Simple Remote ControllerUTY-RHKYWithout operation mode

Wireless Remote ControllerUTY-LNHY

The V-II system supports every users needs by offering a variety of Control systems,including individual control, central control and building management control options.

Wiring system•Wiring construction of the control system is made of power source wiring, transmission wiring and remote controller wiring.•Total wiring length (total length of transmission line) can be extended up to 3,600m (by using signal amplifiers).

*2USB

Adaptor

(Field supplied)

*2

USBAdaptor

(Field supplied)

*2

*1

USBAdaptor

(Field supplied)

*2

BACnet ® Gateway (Software)UTY-ABGX

Group Remote ControllerUTY-CGGY

Touch Panel ControllerUTY-DTGY

*1. BMS/BAS: Building Management System / Building Automation System*2. USB Adaptor is U10 USB Network Interface of Echelon® Corporation.

Transmission line (VRF Network)Module linkRemote controller lineUSB cable

LONWORKS® NetworkEthernetSignal line(Single split system)Group Remote Controller lineThe devices above cannot be connected to the S series.

(Except System Controller & BACnet® Gateway)

Refrigerant system 1 Refrigerant system 2

USB adaptor

USB adaptor

USBadaptor

USB adaptor

Network Convertor

NetworkConvertor

Network Convertor Network ConvertorSignal AmplifierWeb Monitoring Tool Trouble free operation at all times by remote monitoring system.

Transmission lineline is non-polar 2-conductor.

Service ToolExtensive monitoring and analysis functions for installation and maintenance.

2 Remote Controllers Indoor unit can be controlled from both remote controllers.

External Switch ControllerIndoor units can be controlled by combining with Card-key switch such as hotel room.

System without remote controllerTogether with Touch Panel Controller, it is possible to build non remote controller system.

Remote controller lineMaximum 16 units can be controlled

Group Remote ControllerMaximum 8 remote controller groups can be controlled

Touch Panel ControllerOne Touch Panel Controller can control up to 400 groups / 400 indoor units.

System Controller UTY-APGX•Maximum 1,600 indoor units can be controlled. •Air conditioning control •Operation monitoring •Status monitoring system•Electricity charge calculation

IR Receiver KitCassette type indoor unit can be controlled with Wireless Remote Controller

IR Receiver UnitDuct type indoor unit can be controlled with Wireless Remote Controller.

Service Tool

Big multi system

Card key

Single system

Outdoorunit

Indoor unit(Cassette)

Indoor unit(Duct)

SystemController

Touch PanelController

GroupRemote Controller

SimpleRemote Controller

SimpleRemote Controller

Transmission line

Module link

Remote Controller line

Group Remote Controller line

Signal line (single system)

USB cable

Ethernet

LONWORKS® NetworkWireless

Remote Controller

WirelessRemote Controller

External SwitchController

IR Receiverunit

(Remote / Monitoring side)

BACnet® GatewayBACnet®

LONWORKS®

BACnet®

BACnet® Operator Workstation (B-OWS)

NW1

NW2NW3NW4

Combination ofindividual remote controller

Wired, Simple and Wireless Remote Controllers can be used jointly.

Internetor

Public Telephone Line

Internetor

Public Telephone Line

LONWORKS®Network

Building Management System

3,600m

Max. transmissionline length

(Monitoring side)

(Monitoring side)

(Monitoring side)

Web Monitoring Tool

(VRF system side)

Central Remote ControllerUTY-DCGY

CentralRemote Controller

Central Remote ControllerMaximum 100 indoor units can be controlled.

Control Systems for & series

Page 71: Fujitsu 2012 catalog

141140

The room temperature can be controlled by detecting the temperature accurately from the built-in sensor

UTB-YUB/UTY-RNKY

•Simple operation with Built-in Weekly / Daily Timer.•Control up to 16 indoor units.•Up to 2 wired remote controllers can be connected to a single indoor unit.

•A large On / Off button is provided in the centre of the remote controller for easy operation.

•Background light enables easy operation in a darkened room.

•Following an error display, diagnostics can be carried out on the controller.

User-friendly operation

Built-in timers

Wired Remote Controller

Compact remote controller provides access to basic functions

UTB-YPB/UTY-RSKYUTB-YRA/UTY-RHKY (Without operation mode)

•Up to 16 indoor units can be controlled with one remote controller.•Suitable for hotels or offices as it is easily operated with no complex functions.

Simple Remote Controller

Weekly timer: Possible to set ON/OFF time to operate twice each day of the week.Setback timer: Possible to set temperature for two times spans and for each day of the week.At "Weekly timer" + "Set back timer" setup

Indoor temperature can be detected accurately by the inclusion of a thermo sensor in the body of the wired controller. This new wired remote controller and the optional remote sensor allows flexibility in sensor location, suitable for all requirements.

Accurate and comfortable Built-in timersSelect from 4 different timer programs: On / Off / Program / Sleep Program timer: The program timer operates the ON and OFF timer once within a 24 hour period.Sleep timer: The sleep timer function automatically corrects the set temperature according to the time setting to prevent excessive cooling or heating during sleep hours.

System addressingDuring installation work, system addressing can be performed using the Wireless Remote Controller, thus eliminating manual switch setting.

Easy installation and operation•Code selector switch prevents indoor unit mix-up. (Up to 4 codes can be set.)

•Wide and precise transmitting range.

Example of changing sensorRemote Sensor in the bedroom

Wired Remote Controller in the living room

Wired remotecontroller

Indoor unit

Remotesensor

The detecting point can be easily changed

Day Night

Displayed temperature is set temperature.

Specifications Specifications

UTB-YPB/UTY-RSKY UTB-YRA/UTY-RHKYWithout operation mode

UTB-YVB/UTY-LNHY

•A single controller controls up to 16 indoor units.

Wireless Remote Controller Max. controllable

16indoor units

Max. controllable

16indoor units

Max. controllable

16indoor units

Selectable

4daily timers

Functions

*1: "Operation mode" setting is not available. It is recommend to use together with other type controller.

Two methods are available for determining the cause of failure in the event of a malfunction occurs:

Diagnosis check function

Simple installationComponents are compatible with standard switch boxes. Flat back surface allows to be installed wherever it is needed.

WirelessRemote Controller

Indoor unit

Transmission line

Outdoor unit

Simple and sophisticated operations with a choice of 4 daily timers

UTB-YWA/UTB-YWC

IR Receiver Unit

Necessary to control for all duct type by Wireless Remote Controller IR Receiver Unit

Duct type indoor unit

IR Receiver Kit

Cassette type indoor unit can be controlledwith Wireless Remote Controller

WirelessRemote Controller

WirelessRemote Controller

IR Receiver Kit

DC12V is supplied by the indoor unit.

Model name

Power Source

Dimensions (H x W x D) (mm)

Weight (g)

DC 12V

120 x 75 x 14

90 (100 : UTY-RSKYT)

UTB-YPB/UTY-RSKY

DC 12V

120 x 120 x 17

160

UTB-YUB/UTY-RNKY

DC 12V

120 x 75 x 14

90 (100 : UTY-RHKYT)

UTB-YRA/UTY-RHKY

Model

On / Off

Fan control

Operation mode

Room temp. setting

UTB-YPB/UTY-RSKY UTB-YRA/UTY-RHKY

*1

Model name

Battery

Dimensions (H x W x D) (mm)

Weight (g)

DC 12V

122 x 60 x 26.5

150

UTB-YWA/UTB-YWC

1.5V (R03 / LR03 / AAA) x 2

158 x 56 x 20

70

UTB-YVB/UTY-LNHY

DC 12V

213.8 x 213.8x 25.7

140

UTY-LRHYB1

UTY-LRHYB1

UTY-LNHYUTB-YVB

Controller

Page 72: Fujitsu 2012 catalog

143142

Group control of indoor units with simple operation

UTB-YDB / UTY-CGGY

•Up to 8 remote controller groups can be controlled by one Group Remote Controller.

•Up to 64 Group Remote Controllers can be connected in one VRF network system.

•Network Convertor is required to connect Group Remote Controllers to a VRF network system.

(Network Convertor allows up to 4 Group Remote Controllers)

Group Remote Controller

Specifications

DC12V is supplied by a network converter.

Model name

Power Source

Dimensions (H x W x D) (mm)

Weight (g)

DC 12V

120 x 120 x 17

200

UTB-YDB / UTY-CGGY

Max. controllable

64group R.C. in a VRF

network system

Max. controllable

8remote

controller groups

Specifications

UTY-DCGY

Central Remote Controller

Central control of small- and medium-sized buildings and tenants.

Model name

Power Source

Dimensions (H x W x D) (mm)

Weight (g)

Control Panel

DC 5 V

120 x 162 x 26

308

UTY-DCGY

Max. controllable

16groups

Max. controllable

100Indoor units

•Diverse control of indoor units •Weekly timer •Automatic clock adjustment •Error history

Functions

Refrigerantsystem 2

Refrigerantsystem 1

ON / OFF, Operating mode, Room temperature and Fan speed setting can be controlled / monitored centrally or individually.

High performance and compact sizeThe weekly timer is provided as a standard function.1. The timer can be set up for up to 4 times per day. (On / Off,

operating mode, set temperature)2. Allows separate settings for each day of the week.

Built-in weekly timers

Centralcontrol

ON/OFFcontrol

Weeklytimer

•Single Group Remote Controller controls and monitors up to 8 remote controller groups.

Control up to 8 remote controller groups

Hotel

Restaurant

Lobby

21

LoungeOffice room

Guest room

Group RemoteController

NetworkConvertor

Restaurant

Lobby

Office & Lounge

Group Remote Controller 1: To control office room, lounge, restaurant and lobby (8 remote controller groups)

Group Remote Controller 2: To control guest room and launge (7 remote controller groups)

• Individual control and monitor of 100 indoor units • 5 inch TFT color screen • User friendly view and easy operation • External input / output contact • Detachable power supply unit• Corresponds to 7 different languages like English, Chinese, French, German, Spanish, Russian, Polish.

• It allows multiple indoor units grouping (Max.16 groups controlled)• Interlock with external device

System overview

• The control panel and power supply unit can be installed separately.

• For flexibility in installation, the Control panel can be built into the wall or fix on the wall.

Easy Installation

Group : Division A Group : Division B

Group : Hallway

Group : Division C

Group : 3F

Emergency stop function

Group : Tenant A Group : Tenant B Group : Tenant C

Group : 2F

Control panel + Power supply unit

Control panel

CeilingPower supply unit

SW BOX

Setting pattern 1 Setting pattern 2

Wall

Wall

PACKING LIST

Power Supply Unit

100-240V, 50-60Hz, Single phase

99 x 135 x 40

355

Packing List Control Panel / Power Supply Unit / Connecting cable, etc.

Controller

Page 73: Fujitsu 2012 catalog

145144

Emergency stop function

UTY-DTGY•Large-sized 7.5-inch TFT color•LCD Easy finger touch operation•Stylish shape and design to suit all application•No additional component is required for installation•Up to 400 indoor units can be controlled•Selectable 2 display types (Icon / List) in monitoring mode•Corresponds to 7 different languages, English, Chinese, French, German, Spanish, Russian, Polish.

Touch Panel Controller

•Emergency stop function: Air conditioner can be turned off through the external input control

•The stored data can be transferred via USB port•CSV format data edited by PC can be imported to Touch Panel Controller.

Versatility

Automatic clock adjustment

Specifications

Model name

Power Source

Dimensions (H x W x D) (mm)

Weight (g)

Interface

100-240V 50/60Hz

260 x 246 x 54

2,150

USB 2.0

UTY-DTGY

•Wide range of simple-to-understand icons•Operation can be selected using your finger or the dedicated touch pen by pressing the appropriate on-screen icon•Up-to-date status display•Background color identifies current control operation blue for monitoring, green for operational control

Easy operation

Functions

Easy installationSchedule control

Flexible groupingIndividual control

Indoor units operation monitoring

Data transferavailable by USB

CSV format data edited by PC can be imported to Touch Panel Controller.

Max. controllable

400indoor units

•Touch Panel Controller is easily mounted to the wall.•Flat back surface allows to be installed wherever it is needed.

•No additional component is required for installation.

The time setting of each controller can be set in batch automatically.

Control up to 400 indoor units•The central remote controller performs system control after you select All Groups, User Defined Groups, or Individual Remote Controller Groups.

•Accurate control of functions such as Start / Stop, Operating Mode, Temperature, and Air Velocity ensures occupancy comfort.

Central controlAny of 6 functions of the individual remote controller can be locked from the Central Remote Controller: all functions, timer mode, operating mode, temperature setting, filter reset, on/off.All functions can be controlled via the Central Remote Controller only.

Functions•Built-in weekly timer•Memory functions•Error display

Easy Installation•The controller can be installed on any flat surface.•The control panel and transmission adaptor can be installed separately.

•For flexibility in installation, the main unit can be built into the wall or exposed.

Specifications

UTB-YCA

•Up to 400 indoor units / 400 remote controller groups / 64 groups can be controlled by one system.

•Up to 16 central remote controllers can be connected into one system allowing operation and monitoring to be achieved from the central control room, at each floor, by each tenant, or in the plant room.

Central Remote Controller

Functionality in a compact housing with built-in weekly timer

Model name

Power Source

Power Consumption (W)

Fuse Capacity (A)

Dimensions (H x W x D)(mm)

Weight (g)

Control Panel

DC 12V

143 x 296 x 22

550

Transmission Adaptor

220-240V 50-60Hz Single phase

107 x 288 x 100

1,300

4.8

3

UTB-YCA

Individual

Individual Remote Controller Groups

Individual Individual

Individual Individual Individual

All

All Groups

Group

User Defined Groups

Group

Group

GroupGroup

Controllable method

Connecting cable

Power Supply 220-240V

Transmission line

Transmission Adaptor

Control Panel

PACKING LISTPacking List Control Panel / Transmission Adaptor / Connecting Cable

Max. controllable

400remote

controller groups

Max. controllable

400indoor units

Max. controllable

64groups

Controller

Page 74: Fujitsu 2012 catalog

147146

User friendly view and operation

Specifications

UTY-APGX

System Controller

System Controller realizes the advanced integrated monitoring & control of VRF network system from small scale buildings to large scale buildings.

Personal Computer

Operating System

CPU

HDD

Memory

Interface

Other Software Required

AT compatible machine that runs Microsoft® Windows®

•Batched stop •Divers control of indoor units •Oprating & control record•Schedule control •Error display & E-mail nitification •Prohibition setting

Others

Functions

PACKING LIST

Wibe Key Software protection key to be inserted in a USB slot running System Controller. System Controller may only run on a PC with Wibu Key. Remote VRF Explorer software does not require Wibu Key.

CD-ROM Includes the software for System Controller. Both VRF Controller and VRF Explorer software is included. Monitor mode (Site)

Monitor mode (Building)

Monitor mode (Floor) Monitor mode (List) Schedule setting

Main operation monitoring screen Management functions Operation monitoring of each siteMonitoring located site

Microsoft® Windows® XP Professional (Service Pack 3 or later / English version),Microsoft® Windows Vista® Home Premium, Business (Service Pack 2 or later / Corresponds to 7 different languages.*), Microsoft® Windows® 7 Professional (64-bit is not supported. / Corresponds to 7 different languages.*) *English, Chinese, French, German, Spanish, Russian, Polish

USB port is required for each of the followings for Server PC ;• Wibu Key (Software protection key) • Echelon® U10 USB Network Interface (Required for each VRF Network) Ethernet port is required for remote connection using internet.

Intel® Pentium® / Celeron 2 GHz (VRF Controller), 1 GHz (VRF Explorer) or higher

40 GB or more of free space (5 GB for VRF Explorer PC)

2 GB or more (VRF Controller), 1 GB or more (VRF Explorer)

Adobe® Reader® 9.0 or later

Accelerator Requires the internal graphics accelerator be compatible with Microsoft® DirectX® 9.0

Max. controllable

1,600indoor units

Max. controllable

400outdoor units

Max. controllable

4VRF network systems

Model name UTY-APGX

Software

Personal computer must be field supplied. U10 USB Network Interface must be field supplied. Contact Echelon® Corporation or its local sales representative for detail.Product Name : U10 USB Network Interface - TP/FT-10 Channel Model Number: 75010R

• Up to a maximum of 4 VRF network systems, 1600 indoor units, and 400 outdoor units can be controlled.

• Supports VRF S series, V series and V-ll series. • In addition to air conditioning precision control function, central remote control, electricity charge calculation, schedule management, and energy saving functions are strengthened and building manager and owner needs are met.

• Corresponds to 7 different languages (English, Chinese,French, German, Spanish, Russian, Polish)

On site central control

Remote central controlSystem Controller may be used on site or remotely over var ious networks for remote central control. System Controller requires 2 softwares working together. VRF Controller runs on site and communicate with VRF system. VRF Explorer runs remotely and provides user interface and communicate with the VRF Controller. VRF Controller and VRF Explorer program may run in a s ingle PC or in d i f ferent PCs separated by network. By using VRF Explorer software, one PC can perform central control of 10 VRF system sites with max. 20 buildings per site.

Remote centralized control

Max. 4 VRF network systems per site

Building Management Company A (In charge of the day shift)

Internetor

Telephone Lineor

LAN

Internetor

Telephone Lineor

LAN

Building management company,management center, etc.

BuildingManagement Company B

(In charge of the night shift)

Security Company

Headquarters Management Center

A maximum of 10 locations, such as offices or factories

1 VRF Explorer can control or monitor up to 10 sites.

1 VRF Controller can be monitored from any number of VRF Explorers (Up to 5 connections simultaneously).

Office Management Center

VRF Explorer

VRF Explorer

VRF Explorer

VRF ExplorerVRF Explorer

VRF Explorer

VRF Controller

VRF Controller

Internetor

Telephone Lineor

LANVRF Explorer

VRF Controller

Central Monitoring Screenfor all Properties

Special Property Detailed Monitoring Screen

Energy saving management UTY-PEGX:software

Pow

er c

onsu

mpt

ion

Time

Outdoor unit capacityupper limit

Peak cut operationControls overall operation while maintaining comfort according to the overall power consumption target value.

Apportions the power used by indoor and outdoor units and automatically calculates the electricity charge for each tenant.When you want to calculate the power used during a certain period in hotels, etc., computation linked with an electric meter is also possible. (Option)

Outdoor unit capacity saveSets an upper limit of outdoor unit capacity and performs capacity save operation at peak times.

Indoor unit rotation operationReduces annual power consumption by operating indoor units in rotation.

Forced thermostat off range

Target power consumption

Outdoor unit stop range

Outdoor unit capacity control screen

Ideal control line (Use of average power consumption)

Shows change in power consumption by time

Indoor unit rotation screen

Electricity charge apportionment Option

Option

Billing management for users for a set period of time, such as for hotels

Signal transmission line

1Ø, 2wire 230V, 50Hz

DPM

System Controller

Outdoor unit

Room 301 Room 302 Room 303

Room 201 Room 202 Room 203

Room 101 Room 102 Room 103

PowPowePowerrdistribuibubutiotionn

boardd

PowPoweP rdistribuibubutiotion

boardd

CT

3Ø, 4

wire

400

V, 5

0Hz

Controller

Page 75: Fujitsu 2012 catalog

149148 Personal computer must be field supplied. U10 USB Network Interface must be field supplied. Contact Echelon® Corporation or its local sales representative for detail.Product Name : U10 USB Network Interface - TP/FT-10 Channel Model Number : 75010R

•Split type systems can be controlled from a central remote controller or PC controller through connection to the VRF's network convertor. •Standard remote controller and central remote controller provide On / Off control, master control, temperature and fan control, etc.•A single network convertor can be used to connect and control up to 16 single units.

Installation example Installation example

Specifications Specifications

UTR-YLLA / UTY-VLGX•For connection between VRF network system and a LONWORKS® open network for management of small to medium-sized BMS and VRF network system.

•The UTY-VLGX permits central monitoring and control of a VRF network system from a BMS through a LONWORKS® interface.

•Up to 128 Indoor units can be connected to one Network Convertor for LONWORKS®

Network Convertor for LONWORKS®

Transmission specifications (BMS side)

Model name

Power Source

Power Consumption (W)

Dimensions (H X W X D) (mm)

Weight (g)

50-60Hz 220-240V

8.5

67 x 288 x 211

1,500

UTR-YRDA / UTY-VGGXZ1 Model name

Power Source

Power Consumption (W)

Dimensions (H X W X D) (mm)

Weight (g)

220-240V 50/60Hz

4.5

67 x 288 x 211

1,500

UTR-YLLA / UTY-VLGX

Personal Computer

Memory

Interface

Other Software Required

Operating System

CPU

AT compatible machine that runs Microsoft® Windows®

Packing List CD-ROM / Wibu Key

Microsoft® Windows® XP Professional (Service Pack 3 or later / Corresponds to 7 different languages.*)Microsoft® Windows Vista® Home Premium, Business (Service Pack 2 or later / Corresponds to 7 different languages.*)Microsoft® Windows® 7 Home Premium, Professional (Corresponds to 7 different languages.*)*English, Chinese, French, German, Spanish, Russian, Polish

USB port (x 2-5) is requiredEthernet port is required

Intel® Pentium® / Celeron®, AMD Athlon / Duron processor 2 GHz or higher

2 GB or more

40 GB or more of free spaceHDD

Adobe® Reader® 9.0 or later

UTR-YRDA / UTY-VGGXZ1 •This network convertor is to be used for connecting single split system or group remote controller with the VRF network system.

•Please select the function by switching the dip switch during the installation.

Network Convertor

UTY-ABGX•The VRF network system can be incorporated into a Building Management System.•Enables central control of up to 1,600 indoor units through BACnet®, a global standard for open networks. •Conforms to ANSI / ASHRAE Standards® 135-2004 BACnet® Application Specific Controller (B-ASC) BACnet® / IP over Ethernet.

•Connects up to 4 VRF network systems (1,600 indoor units / 400 outdoor units) per gateway.•Supports VRF S/V series and V-II series

BACnet® Gateway

* 2 refrigerant circuits can be covered by a single network convertor. Up to a total of 16 network convertors and central remote controller adapters can be connected in a single VRF network system.

78kbps

FT-X1 (Echelon® Corporation)

Free topology

None(It attaches at the terminal of a network.)

Transmission speed

Transceiver

Transmission way form

Terminal resistor

Software

CD-ROM(Software)

SoftwareProtection Key

Installation example

Lighting facilities

Security system

Automatic fire alarm interface

Ventilation system

BACnet Operator Workstation (B-OWS)

USB adaptor (Field supplied)

USB adaptor (Field supplied)

USB adaptor (Field supplied)

USB adaptor (Field supplied)CD-ROM

(Software)Software

Protection Key

(UTY-ABGX)BACnet Gateway

Outdoor unitIndoor unit

VRF network system 1

VRF network system 2

Indoor unit

BACnet

Max. 4 VRF network systems *1: USB adaptor is U10 USB Network

Interface of Echelon® Corporation.

®

®

®

= BACnet® Gateway for each system.= USB cable= Transmission line (VRF Network)= Ethernet

*1

Outdoor unit

Max. controllable

128indoor units

Max. controllable

4Units to BMS

Max. controllable

4VRF network systems

Max. controllable

400outdoor units

Max. controllable

1,600indoor units

Max. controllable

16Network

Convertor units

Model name UTY-ABGX

PACKING LIST

(UTR-YRDA) (UTR-YLLA)

Used for connecting Group Remote Controller

Big Multi

VRF networksystem

System Controller Single Split

Group of Single Split

4 group remort controllers can be connected to a single Network convertor.

VRF networksystem

Network Convertor

Group Remote Controller

Please consult your distributor for connectable split type air conditioner. Up to 100 network convertors may be connected in a single VRF network system. A single network convertor is considered as a single refrigerant system, irrespective of the number of connected single models.

Network Convertor

USBadaptor

General-purpose building control computer(LONWORKS® device)

LONWORKS® Network

NetworkConvertor

VRF network system 1 Lighting facilities

Security system

Automatic firealarm interface

Ventilation system

Max. 128 indoor unitsMax. 100outdoor units

Max. 4 NetworkConvertor

VRF network system 2

Max. 128 indoor unitsMax. 100outdoor units

The BACnet Gateway version 2.0 is eligible to display BTL Mark. Founded by BACnet International, BTL (BACnet Testing Laboratories) is an indication of worth trusting for its quality after passing the strict tests.

Adaptor & Convertor

Page 76: Fujitsu 2012 catalog

151150

UTY-VSGX•Transmission Line length can be extended up to 3,600m for V-II series (2,000m for S series) with multiple Signal Amplifiers.

•Up to 8 signal amplifiers can be installed in a VRF network system.•A signal amplifier is required,(1) When the total wiring length of the transnission line exceeds 500m.(2) When the total number of units on the transnission line exceeds 64.

Signal Amplifier

External Switch Controller

Wiring connection

Specifications Specifications

UTY-ASGX

•Operation status can be checked and analyzed to detect even the smallest abnormalities•Storage of data on system operation status on a PC allows access even from off site.•Up to 400 indoor units (a single VRF network system) can be controlled and monitored for large scale buildings or hotels•This software can be connected to any point of transmission line with USB adaptor (field supplied).•Supports VRF S/V series and V-II series.

Service Tool

Extensive monitoring and analysis functions for installation and maintenance

Personal Computer

Model name

Operating System

CPU

HDD

Memory

Interface

Software

Hardware

AT compatible machine that runs Microsoft® Windows®

Installation example

•Equipment Detail (List)•Error History•Remote File Download•System List•Commissioning Tool

PACKING LISTPacking List CD-ROM / Wibu Key

Installation exampleAuto mode operation, which switches the cooling and the heating automatically, is enabled by using the sensor switch and External Switch Controller. Note: All indoor units will operate in the same mode.

Microsoft® Windows® XP Professional (English version / Service pack 3 or later), Microsoft® Windows® Vista® Home Premium, Business Edition (English version / Service pack 2 or later), Microsoft® Windows® 7 Professional (64-bit is not supported. / English version / Service pack 1 or later)

USB port for U10 USB Network Interface and Software protection key.

Intel® Pentium® / Celeron®, AMD AthlonTM / DuronTM 1 GHz or higher

Internet Explorer 6.0 or 7.0 or 8.0 / Adobe® Reader® 9.0 or later

CD-ROM drive

USB port (for U10 USB Network Interface Max.4, Software protection key)Following interface is required for remote connection:Public Telephone LIne : Modem is requiredInternet using LAN : Ethernet port is required

1 GB or more

10 GB or more of free space 40 GB or more of free space

B

AD

Signal Amplifier

C

Electrical wiring

UTR-YESA / UTY-TEKX

•In combination with a field supply Card-Key Switch or other sensor, the External Switch Controller allows control of the ON / OFF, Room temperature, Fan speed and Master control functions. This makes this product suitable for installations such as hotel rooms.

•Card-key or other sensor switches are available as a field supplied parts.

Air conditioner switching can be controlled by connecting other sensor switches

RemoteController

Line

Indoor Unit 1 2 3 E COM SW1 SW2

Card-key

Externalinput

RemoteController

Line

Indoor Unit 1 2 3 E COM SW1 SW2

Sensor SW

Externalinput

Card-key(Field supplied)

Sensor SW(Field supplied)

External Switch Controller

External Switch Controller

Note 1. Please choose a thermosensor switch which can be set up for T1 and T2.

Note 2. The remote controller's operation is prior to the auto mode operation.

Roo

m te

mp.

Time

T1

T2

Cooling

Heating

Model name

Power Source

Dimensions (H X W X D) (mm)

Weight (g)

DC 12V

120 x 75 x 30

90

UTR-YESA / UTY-TEKXModel name

Power Source

Power Consumption (W)

Dimensions (H X W X D) (mm)

Weight (g)

220-240V 50/60Hz

4.5

67 x 288 x 211

1,500

UTY-VSGX

DC12V is supplied by the indoor unit.

Software

UTY-AMGX

•Troubleshooting is performed by monitoring each air conditioning unit remotely during periodical system checks.•Error notification can be automatically transmitted to several locations using the internet*1.•Requires either a dedicated internet connection or public telephone line.•Determination of an error occurrence can be made through error warnings and equipment status information obtained from a remote location.•The monitoring data in a remote side can be optionally downloaded. And, this data can be displayed in offline mode of the service tool.•Monitoring side computer is not required to install special software, requires only general web browser.•Supports VRF S/V series and V-II series.

Web Monitoring Tool

Product features

Software

(Field supplied)

Refrigerant piping

Tran

smis

sion

line

Indoor unit

Indoor unit

USB adaptor(Field supplied)

Functions•Equipment Detail (Diagram)

Support 4 VRF network systemsUSB adaptor (max. 4 adaptors per PC) permit, monitoring of up to 1,600 indoor units.Suitable for large-scale buildings or hotels.

VRF NetworkSystem 2

VRF NetworkSystem 3

VRF NetworkSystem 4

Indoor unitMax. 400

Indoor unitMax. 400

Indoor unitMax. 400

Indoor unitMax. 400

Web Monitoring System

Indoor unit

Transmission line

USB adapter(Field supplied)

Outdoor unit

WebMonitoring

Tool

USB adaptorsVRF Network System SideMonitoring Side

orInternet

PublicTelephone

Line

UTY-ASGX UTY-AMGX

Personal computer must be field supplied. U10 USB Network Interface must be field supplied. Contact Echelon® Corporation or its local sales representative for detail.Product Name : U10 USB Network Interface - TP/FT-10 Channel Model Number: 75010R

*1: Use of internet mail system required.

1 GB (Vista, 7), 512 MB (XP) or more

Max. Monitorand controll

100outdoor units

Max. Monitorand controll

400indoor units

VRF network systemcan be supported

41,600indoor units

can be supported

SU MO TU WE TH FR SA

7

3 126 9 15 18 21

T1 = ON, T2 = OFF

To individual dry contact

Sensor SW(Field supplied)

External Switch Controller (UTY-TEKX)VRF Network

System 1

Adaptor & Convertor, Service & Maintenance

Page 77: Fujitsu 2012 catalog

153152

Optional Parts for VRF

Wired Remote ControllerIndividual control

Without operation mode

Wireless Remote Controller

IR Receiver Kit

IR Receiver Unit For All Duct type

For All Cassette type

Group Remote ControllerCentralized control

Central Remote Controller

Touch panel Controller

System Controller

Network ConvertorAdaptor & Convertor

Network Convertor for LONWORKS®

BACnet® Gateway

Signal Amplifier

External Switch Controller

EV KitRefrigerant Piping Parts For Compact Wall Mounted type

Decoration PanelPanelFor Compact Cassette type

For Cassette type

Service Tool (software)Service

Web Monitoring Tool (software)

Auto Louver Grille Kit

Remote Sensor Others For All Duct type

Drain Pump Unit

Wide Panel

Panel Spacer

Fresh Air Intake Kit

Air Outlet Shutter Plate

For Cassette type

Insulation for High Humidity

For Compact Cassette type

For Cassette type

For Compact Cassette type

For Cassette type

For Cassette type

For Cassette type

For Ceiling type

For Compact Duct / Low Static Pressure Duct / Duct type

For Low Static Pressure Duct / Duct / Ceiling type

For Low Static Pressure Duct / Duct type

For Low Static Pressure Duct / Duct type

For High Static Pressure Duct type

For Compact Cassette type

S

-

-

-

-

-

-

-

-

-

J-II V-II

UTB-YUB

UTB-YPB

UTB-YRA

UTB-YVB

UTB-YDB

UTB-YCA

UTY-APGX

UTR-YRDA

UTR-YLLA

UTY-ABGX

UTY-VSGX

UTY-TEKX / UTR-YESA

UTG-UDYD-W

UTD-LF60KA

UTD-LF25NA

UTD-RF204

UTD-SF045T

UTZ-VXAA

- UTZ-VXGA

- UTR-YDZB

- UTR-YDZC

UTB-YWA

UTY-RNKY

UTY-RSKY

UTY-RHKY

UTY-LNHY

UTY-LRHYB1

UTY-CGGY

UTY-DCGY

UTY-DTGY

UTY-APGX / UTY-PEGX

UTR-EV09XB / UTR-EV14XB

UTG-UFYC-W

UTY-VGGXZ1

UTY-VLGX

UTY-TEKX

UTD-RS100

UTG-AGYA-W

UTG-BGYA-W

UTD-GXSA-W / UTD-GXSB-W / UTD-GXSC-W

-

UTZ-KXGA / UTZ-KXGB

UTZ-KXGC

UTZ-PX1BBA / UTZ-PX1NBA

UTR-DPB24T

UTD-SF045T

UTD-RF204

UTD-LF25NA

UTD-LF60KA

UTD-RS100

UTY-AMGX UTY-AMGX

UTY-ASGX UTY-ASGX

UTG-UGYA-W

UTB-YWC

TypeOptional Parts List

Simple Remote Controller

With operation mode

Long Life Filter

Flange

Refrigerant Piping PartsConnection Units

Separation Tube

UTR-BP54MA / UTR-BP90MA UTR-BP090X

For S series For J-II & V-II Series

Gas Pipe

Liquid Pipe

UTR-BP180X UTR-BP567X

UTR-CP567X

For V-II Series

Outdoor Unit Branch Kit

UTR-EV09XB / UTR-EV14XB

EV Kit

For V-II Series

For without EV Kit model(J-II & V-II Series)

For Compact Wall Mounted type

Gas Pipe

Liquid Pipe

Gas PipeLiquid Pipe

RB (Refrigerant Branch) Unit

UTF-Y54A1A UTF-Y90A4A

For S series

Single type Multi type

Header

UTR-HD906R UTR-HD908R

For S series

Headers are available for installation as necessary.

*Reducer is attached to each header kit.

Separation tubes are available for installation as necessary.

Gas Pipe

Liquid Pipe

Gas Pipe

Liquid Pipe

UTR-H0908L / UTR-H1808L* *For V-II Series onlyUTR-H0906L / UTR-H1806L*

Liquid Pipe

Gas Pipe

For J-II & V-II Series

Page 78: Fujitsu 2012 catalog

155154

Optional Parts for VRF

Controllers / Adaptor & Convertor Panel / Service

Others

Panel Service

For Cassette type

For Duct type

For Ceiling type

UTZ-PX1BBA / UTZ-PX1NBA

Flange

UTD-RF204(Round)

UTD-SF045T(Square)

Auto Louver Grille Kit

UTD-GXSA-W (For 07/09/12/14 type)UTD-GXSB-W (For 18 type)UTD-GXSC-W (For 24 type)

Indoor unit950

Panel 600

600(mm) Panel spacer

242mm

UTG-UFYC -W UTG-UGYA-W

UTG-AGYA-W

Wide Panel

Air Outlet Shutter PlateShuts the air outlet when only using as 2 or 3 blow out.

UTG-BGYA-W

Panel Spacer

UTZ-VXAAFor Compact Cassette type

UTZ-VXGAFor Cassette type

Fresh Air Intake Kit

UTG-UDYD-W

UTZ-KXGA / UTZ-KXGB / UTZ-KXGC

Insulation Kit For High Humidity

For Compact Cassette type / Cassette type

Insulation Kit

Remote Sensor Unit

UTD-RS100

New amenity space can be offered by installing the Remote sensor.

Drain Pump Unit

UTD-LF60KA UTD-LF25NA

Long-Life Filter

Drain Pump Unit

UTR-DPB24T

Controllers for Individual Control

Controllers for Centralized Control

Adaptors &Convertors

System Controller

UTY-APGX / UTY-PEGX

Touch Panel Controller

UTY-DTGY

Monitor ModeMonitor Mode 10/11/2008 Thu. 02:20 PM

AllPassage

ScheduleSchedule

OperationOperation

DownDownUpUpTopTop IconIcon

Name SetTemp.

RCProhibitExpandExpand Status

Lobby

Passage

Entrance

Staff Room

PC Room

Heat

Heat

Auto

Mode

21.5˚C High

21.5˚C Med

Low

Fan

On

On

On

On

Off

Cool

24.0˚C

Auto26.0˚C

On/OffOn

AllModeTemp.TimerFilter

Mng´g Op ModeOP Restricted

ScheduleFilter Sign

MixedHeat

GroupError

Cool/DryAuto/Fan

RC Prohibition

SettingSetting

Cancel AllCancel All

Select AllSelect All

OnOn

OffOff

OnOn

OffOff

OnStatus: On

Central Remote Controller

UTY-DCGYUTB-YCA

Group Remote Controller

UTB-YDB / UTY-CGGY

External Switch Controller

UTR-YESA / UTY-TEKX

Signal Amplifier

Network Convertorfor LONWORKS®

UTR-YLLA / UTY-VLGX

BACnet® Gateway

UTY-ABGX

Network Convertor

UTR-YRDA / UTY-VGGXZ1

Wired Remote Controller

UTB-YUB /UTY-RNKY UTB-YRA / UTY-RHKYWithout operation mode

Simple Remote Controller Decoration Panel Service Tool Web Monitoring Tool

UTB-YPB / UTY-RSKYWith operation mode

UTY-LNHY

Wireless Remote Controller

UTB-YVB

IR Receiver UnitFor Cassette type

UTY-LRHYB1

CD-ROM (Software)

Software Protection Key

UTY-VSGX

UTR-YDZCFor Cassette type

UTR-YDZBFor Compact Cassette type

For Duct type

UTB-YWA / UTB-YWC

UTY-ASGX

CD-ROM (Software)

UTY-AMGX

CD-ROM (Software)

Page 79: Fujitsu 2012 catalog

156

Thanks to efficient recovery of thermal energy lost during Ventilation, you can save an air-conditioning fee.

Thanks to a drastic reduction of load incurred by outside air,you can make air-conditioners more compact in parallel with the recovery of thermal energy.

In a cooling mode, a highly humid open-air is brought near to a dehumidified room atmosphere and then supplied. In a heating mode, a room humidity is transferred to the dry outside air and then supplied.

The ducts of the unit and the heat exchange element are characteristic of sound shield effect, so that the office and store environment can be preserved.

High efficiency and low noise are achieved using a highly efficient element.Comfortable air-conditioned environment is provided by effectively determining whether to use heat-exchange ventilation or normal ventilation while meeting diverse needs.

Suppresses indoor temperature changes while providing fresh air

Energy Recovery VentilatorMore Comfortable Air Conditioning

Page 80: Fujitsu 2012 catalog

159158

Energy Recovery Ventilator

81059931514260065519

27013515988241495

219144

Energy consumption is dramatically reduced by using a counter-flow heat-exchange element. Air conditioning load is reduced by approximately 20%, resulting in significant energy savings. Recovers up to 77% of the heat in the outgoing air.

With the cross-flow element, air moves in a straight line across the element. With the counter-flow element, air flows through the element for a longer time (longer distance), so the heat-exchange effect remains unchanged.

High Efficiency

Energy efficiency and ecology

Features of heat exchange element

Easy Installation and Maintenance

Counter-flow heat exchange element used for reduced noise and slimmer, more compact body shape.

Slim shape and easier installation

Adoption of straight air supply / exhaust system: Duct design is simplified because the air supply / exhaust ducts are straight.Since each unit can be mounted in reverse position, only one inspection hole is needed for two units: Two units can share one inspection hole so duct work is easier and more flexible.

Reverse mountable direct air supply / exhaust system

More Comfort

Significantly reducing low pressure loss and noise allows low-noise operation of 32 dB (High) or less for models with a capacity of 500 m3/h or less, and 37.5 dB (High) for models with a capacity of 1,000 m3/h.

Quiet operation

Cleaning reduced due to the special material heat exchanger. The nylon/polyester fibre filter offers high dust retention capacity.

Long heat-exchanger service life

Other element(Cross-flow element)

Fujitsu element(Counter-flow element)

Straightunit

Reversemounted unit

Outside airExhaust air Exhaust air

Supply airRoom air Room air

UTZ-BX025A/BX035A/BX050A

Height

270mm

20%Energy saving

UTZ-BX080A/BD100A

Height

388mmInspection

hatch

Inspectioncover

Specifications

* The noise level must be measured 1.5 m below the centre of the unit.

Dimensions (Unit : mm)Models: UTZ-BX025A / UTZ-BX035A / UTZ-BX050A / UTZ-BX080A / UTZ-BD100A

Maintenance space

Maintenance opening

UTZ-BX025AABCDEFGHIJKLMNO

81080448016260086019

27014515988241495

219144

UTZ-BX035A89090450020260096019

270145159962414107246194

UTZ-BX050A1,25088442822860094019388194218

1,32261285258242

UTZ-BX080A1,2501,134678228600

1,19019388194218

1,32261285258242

UTZ-BD100A

UTZ-BX080A UTZ-BD100A

UTZ-BX025A UTZ-BX035A

UTZ-BX050A

Energy recovery ventilator unit offers maximum comfort and greater energy savings.

Input powerAir flow rateExternal static pressure

Hea

t E

xcha

nge

Vent

ilatio

nN

orm

al

Vent

ilatio

n

DimensionsWeightOutlet duct diameterOperation rangeMaximum humidity

Rated flow rate

Model No.

250 m3/h

UTZ-BX025A

220-240V , 50Hz

350 m3/h

UTZ-BX035A

500 m3/h

UTZ-BX050A

800 m3/h

UTZ-BX080A UTZ-BD100A

1000 m3/h

Power sourceW

m3/hPa

%

%

%

dB*

dB*

Wm3/hPa

mmkg

°C%

mm

(Extra high)/High/Low(Extra high)/High/Low(Extra high)/High/Low

(Extra high)/High/Low(Extra high)/High/Low(Extra high)/High/Low(Extra high)/High/Low(Extra high)/High/LowW×D×H

(Extra high)/High/Low

(Extra high)/High/Low

(Extra high)/High/Low

Adopts a highly efficient counter-flow heat exchange element

Heat exchanger Outside air

Exhaust air

Supply airRoom air

Heat exchange ventilationWhen a room is cooled or heated, the exhausted cooling / heating energy is recovered by heat-exchange ventilation.

Normal ventilationThis is used in the spring and autumn, when rooms are not cooled or heated, that is, when there is little difference between the indoor and outdoor air conditions. In addition, at night during the hot season, when the outside air temperature drops the outside air is drawn inside without heat exchange, alleviating the load on the air conditioning equipment.

Heat exchange ventilation and normal ventilation

119 / 99 / 79250 / 250 / 170

90 / 80 / 37

154 / 124 / 117350 / 350 / 280

95 / 65 / 42

214 / 169 / 151500 / 500 / 370

105 / 70 / 38

347 / 309 / 302800 / 800 / 650140 / 110 / 70

445 / 360 / 3321,000 / 1,000 / 810

90 / 55 / 35

75 / 75 / 77

63 / 63 / 66

70 / 70 / 73

28 / 26 / 21119 / 98 / 79

250 / 250 / 17090 / 80 / 37

27 / 26.5 / 21.5882×599×270

29150

-10 to 4085

75 / 75 / 77

66 / 66 / 69

69 / 69 / 71

32 / 29 / 25151 / 119 / 113350 / 350 / 280

95 / 65 / 4231 / 30 / 26

882×804×27037

150-10 to 40

85

75 / 75 / 76

65 / 65 / 68

71 / 71 / 74

38 / 36.5 / 32337 / 300 / 297800 / 800 / 650140 / 110 / 7038.5 / 37 / 33

1,322×884×38871

250-10 to 40

85

75 / 75 / 76

65 / 65 / 68

71 / 71 / 73

37.5 / 36 / 31438 / 358 / 329

1,000 / 1,000 / 81090 / 55 / 35

38 / 36.5 / 31.51,322×1,134×388

83250

-10 to 4085

75 / 75 / 77

62 / 62 / 67

67 / 67 / 71

34 / 31 / 25210 / 161 / 145500 / 500 / 370

105 / 70 / 3834 / 32 / 26.5962×904×270

43200

-10 to 4085

Sound pressure levelInput powerAir flow rateExternal static pressureSound pressure level

Temperature ExchangeEfficiencyEnergy ExchangeEfficiency Cooling

Energy ExchangeEfficiency Heat pump

Page 81: Fujitsu 2012 catalog

160

Capacity

EER - Energy ClassCOP - Energy Class Running CurrentMoisture Removal

Air Flow (High)Noise (Indoor)

Net Dimension H x W x D

Operation RangeCooling

Super PowerSuper QuietSuper WaveInstant Air Exchange

HeatingRefrigerant

Feature

HeatingCooling/HeatingPower Consumption

Power SourceCooling

Cooling

Indoor / OutdoorCooling

HeatingCooling/Heating

°CDB

kW

kg(lbs)

A

W/W

m3/h

I/hdB(A)

mm

V/ Ø/Hz

kW

21~430~21

Model No. AFY16UA

230/1/504.554.30

1.81/1.622.51-E2.65-E8.0/7.2

2.156.5/51.5

620400x660x633

61(134)

R410A

For AFY Models

Minimum

140° Maximum

Swing

Unrestricted direction of airflow. The louver allows airflow coverage as wide as 140°. Mounting the louver in the center provides coverage of an area as wide as 140°. Cold or warm air is distributed throughout the room.

The filter can be cleaned without removing the front panel.

H/L

Quickly transforms your roominto an oasis

AFY16UA

Specifications

Window type Air ConditionersCompact, High Power, and Low Noise

Page 82: Fujitsu 2012 catalog

162

Complete Solution meets various needsThe clean energy produced by reliably delivers “comfort” to diverse spaces in the home up to the living room, bedrooms, bath and swimming pool.

is an Economical and Clean hot water heating system by Heat Pump

RadiatorDomestic hot water

Swimming pool

Floor heating

Domestic hotwater tank

Absorbing the free energy from atmosphere. Heat pump system requires only 1kW of electricity to generate 3 to 5 kW thermal energy.

1 kWhelectricity

Heat pump system

3 to 5 kWhof heat

Comfort heating

2 to 4 kWhAmbient air

High Power

Comfort

Compact

164

164

165

Page 83: Fujitsu 2012 catalog

165164

•2 Zone individual control (2 under floor heating zones or under floor heating + radiator zone, etc.)*

Indoor unit

*Optional parts are required.

Radiator

Floor heatingValve

Pump

Pump

Outdoorunit

~50°C

~35°C

2nd Circuit Kit

2 Zone individual control

2 Zone individual control

High leaving water temperature of 60°C keeps to -20°C of outdoor temperature without using backup heater.

-10-15 -5 0 5

40

-20

50

60

Leav

ing

wat

erte

mpe

ratu

re (°

C)

Powerful Heating & High Efficiency

High leaving water temperature

High Power model

Comfort model

High COP

Air to water heat pumps work with much more efficiency and save more energy than a traditional heating system.

4.30

3.90

High Power model

Comfort model

*The data refer to 16kW type Condition : Outdoor Temp. 7°C Heating Temp. 35°C.

Intelligent Control

High Reliability

High clean and durability

•Corrosion protected •No fouling through heat exchanger construction•Hot water is permanently available

Highly efficient water heat exchanger

Double-pipe water heat exchanger with built-in tank to reduce loss

Stainless steel buffer tank

Optimum co-axial heat exchanger

Anti-freeze is unnecessary

Warm refrigerant flow

Heated water

Compact model

WPYA080LAWPYA100LA

UTW-SCBYAControl box

High Power modelSPLIT TYPE SPLIT TYPE MONOBLOC TYPE

Comfort model

Indoor unitIndoor unitWSYA050DAWSYA065DAWSYA080DA

WSYG140DB6WSYK160DA9

WSYA095DAWSYA128DAWSYA155DA

AOYA18LALLAOYA24LALL

AOYA45LBTLAOY54LJBYL

WOYK112LATWOYK140LATWOYK160LAT

WOYG112LBTWOYG140LBT

Outdoor unit

Monobloc unit

Outdoor unit

AOYA30LBTL

Nobackupheater

Nobackupheater

Outdoor temperature (°C)

Outdoor temperature (°C)

-10-15 -5 0 5

40

50

60

-20

55

Leav

ing

wat

erte

mpe

ratu

re (°

C)

High COP is realized by using a DC twin rotary compressor, inverter technology, and high efficient water heat exchanger.

4.50

4.35

8 kW

10 kW

High COP

*Condition : Outdoor Temp. 7°C Heating Temp. 35°C.

High Reliability

Anti-freeze function

Water circulation and compressor can be automatically performed at low outdoor temperature. Freezing of circulated water can be prevented.

•No installation of refrigerant circuit connections.•Closed type enables decrease in the supply frequency of circulating water.

•Easy access for maintenance operations

Easy installation & maintenance

Time

ON OFF

High

Low

Anti-freeze mode

Outdoor temperature

Settingtemperature

Wired remote controller(control box) is adopted standard.

Intelligent Control

High leaving water temperature of 55°C keeps to -20°C of outdoor temperature without heater.

Compact & High Performance

High leaving water temperature

•Automatic heating curve control•Cooling operation is possible*•Anti-Legionella function•Possible to docking the boiler and electric heater for backup

Twin Rotary Compressor with Linear Control Injection port

Injection port

FUJITSU GENERAL’s advanced Linear Control Injection Technology (High Power model)

Control box

Compact & light weight design

850 mm

330 mm

Weight

82kg88

1.5

mm

*Optional parts are required.

And more

It realizes the high condensing temperature without overheating discharge gas temperature by Linear Control Injection process during compression.

Linear Control Injection

Normalrefrigerantcircuit

High compression

Page 84: Fujitsu 2012 catalog

167166

Smart & Comfort Control

Optional parts

UTW-KBSXA

Boiler Connection Kit

UTW-KCLXA

Cooling Kit

UTW-KCHXA

UTW-KDWXA

DHW Kit

UTW-KZSXA

2nd Circuit Kit

UTW-TEVXA

UTW-T20XA

DHW Tank200L

UTW-T30XA

DHW Tank 300L

UTW-KSPXA

Swimming Pool Kit

UTW-ESPXA

Heat exchanger for swiming pool

UTY-XWZXZ2

External Indication Kit

High Flow Rate Circulating Pump Kit

UTW-C75XA UTW-C55XA

Remote Control Room Thermostat

UTW ESPXA

g p

UTW KBSXA

UTW-KDWXA

HW Kit

Balancing Vessel

Cooling Kit (High flow rate)

UTW-PHFXA

Comfort

Flexible heating circuit

Automatic hot water temperature control matched to the application can be set. In addition, set temperature coefficient offset can be adjusted easily high or low side matched to the usage conditions.

Simple operation mode setting•Selecting the heating mode

Large LCD display•Operation status display•Error display / Error history

Navigation and setting•Selecting the heating menu

•Setting program timerThe growth of Legionella in DHW tank is suppressed and safe and clean hot water is supplied at all times.

Optional remote controller allows controls of hot water depending on indoor temperature.

Comfort/Reduce mode switching automatically according to outdoor temperature

Anti-legionella function

Remote control-extension

Programmed operation

Automatic mode

Day-Weekly timer setting

Heating mode

•The setting of programmed operation can be easily set.•Changing the heating mode linked with time is possible.

•The day-weekly timer can be set up for up to 3 times per day.•Allows separate settings for each day of the week.

Holiday timer setting•The holiday timer can be set up for up to 8 periods

•If you are absent for a long time in the winter, freezing of room can be prevented.

Convenience

Outdoor temperature (°C)Low High

High

Low

+4.5°C

-4.5°C

6 9 12 15 18 21 24Time

Monday-Friday

Setting heating curve

11 12 1 2 3 Date

Holiday timer Day-Weekly timer

Leav

ing

wat

erte

mpe

ratu

re (°

C)

Constant comfort temperature

Comfort mode

Constant reduce temperatureReduce mode

Stand-by mode with anti-frost protection

Protection mode

6 9 12 15 18 21 24Time

Saturday-Sunday

Room Thermostat(Option)

Remote Control(Option)

Outdoor unit

Indoor unit

orFloor heating Radiator

(Split type)

OutdoorSensor

Extendibility

Installation example The water heating system can be freely constructed for a wide range of applications from floor heating to hot water showers.

Design Versatility

Indoor unit

Boiler

Radiator

Valve

Valve

Valve

Pump

Pump

Tank

Outdoorunit

Under floor heating

Hot water showerIndoor unit

RadiatorValve

Valve

Pump

Pump

Tank

Outdoorunit

Under floor heating

Hot water shower

Indoor unit

Outdoorunit

Under floor heating

Indoor unit

Radiator

Valve

Pump

Pump

Outdoorunit

Under floor heating

3 types of heat distribution System for low outdoor air temperatures (additional heating boiler connection)Under floor heating + Radiator + Sanitary hot water

Single heating systemUnder floor heating

2 system simultaneous heating (Individual control)

Under floor heating + Radiator

Under floor heating + Radiator + Sanitary hot water

Meets diverse needs by combining with optional parts.

Diverse operation control

OPTIONS

2-temperature simultaneous heating Floor heating + Radiator heating(Split type only)

Operation together with boiler at low outdoor temperature

Temperature control of swimming pool (Controlled at 35°C)

Page 85: Fujitsu 2012 catalog

169168

DimensionsSpecifications (Unit : mm)

Indoor Units Comfort model

Compact model

Indoor Units High Power model

WSYA050DA / WSYA065DA / WSYA080DA WSYA095DA / WSYA128DA / WSYA155DA

Outdoor Units Comfort modelAOYA45LBTL / AOY54LJBYLAOYA30LBTLAOYA18LALL / AOYA24LALL

WPYA080LA / WPYA100LAControl BoxUTW-SCBYA

66790

10

300

578

347

77900

830

21

33031 12

400

Outdoor Units High Power modelWOYK112LAT / WOYK140LAT / WOYK160LAT

WOYG112LBT / WOYG140LBT

540155 155

90 60275

330

240

522.

533

5110

180

881.

5

116

357

850

436 152

171

1290

900

21

33031 12

400

48088

235

450

1034

1000

ØM26x34 ØM26x34

WSYG140DB6 / WSYK160DA9

1290

900

21

33031 12

400

77

1290

900

21

33031 12

400

77

Outdoor unit

Capacity range (kW)Series name

Input powerCOP

+7°C / +35°C floor heating

-7°C / +35°C floor heating

+7°C / +45°C radiators

-7°C / +45°C radiators

Input powerCOP

Input powerCOP

Input powerCOPCapacityBackup heater

Dimensions H×W×DWeight (Net)Buffer tank capacityExpansion vessel capacityLeaving water temperature range

Rated

Flow / ReturnWater pipe connection diameter

Indoor unit Model name

Model name

Heating capacity

Heating capacity

Heating capacity

Heating capacity

Power source

Power source

Current

Noise level (Sound pressure)Dimensions H×W×DWeight (Net)Refrigerant

Operation range

Connectionpipe

Diameter

Water circulation

kW

kW

kW

kW

kW×pcs.

mmkgLL

L /min

°Cmm

A

dB(A)mmkg

kg

mmm°C

mmmm

Comfort seriesType Split system

High Power series

RatedMax

LiquidGasMini / MaxMaxMaxHeating

LengthLength (chargeless)Height difference

Capacity range (kW)Series name

kWInput powerCOP

+7°C / +35°C floor heating

-7°C / +35°C floor heating

+7°C / +45°C radiators

-7°C / +45°C radiators

kWInput powerCOP

kWInput powerCOP

kW

mmdB(A)

A

Input powerCOP

Dimensions H×W×D

Rated

kg

kg

Noise level (Sound pressure)Current

Monobloc unit Model name

Heating capacity

Heating capacity

Heating capacity

Heating capacity

L

Power source

L /min

°C

mm

Water circulation

Type

Weight (Net)Expansion vessel capacity

Leaving water temperature range°COperation range

Water pipe connection diameterRefrigerant

Monobloc systemCompact series

1Ø 230V, 50Hz

881.5 × 850 × 330828

Ø25.4 / Ø25.4

8 ~ 55-20 ~ 35

R410A1.5Refrigerant amount

Rated

Heating

+2°C / +35°C floor heating

Input powerCOP

Heating capacitykW

+2°C / +35°C floor heating

kWInput powerCOP

Heating capacity

Mini / Max

Mini / Max

Flow / Return

Refrigerant amount

*2

8

WPYA080LA

8.001.784.507.402.732.717.102.932.427.802.233.506.502.982.18

22.910.0 / 30.0

518.30

*2

1111.202.514.46

11.203.922.86

11.203.453.25

10.502.903.6210.504.162.52

9.0(3.0 × 3 pcs.)

3.608.50

32.120.0 / 40.0

53*2

1616.003.724.30

15.005.552.70

15.104.423.42

14.506.382.27

9.0(3.0 × 3 pcs.)

15.104.873.10

5.5010.50

45.928.3 / 56.7

56*2

AOYA18LALL

10.80

578 × 790 × 30040

201.25

Ø6.35Ø12.705 / 15

1515

39*3

R410A

1034×450×48052.5258

1Ø 230V, 50Hz

1Ø 230V, 50Hz

-15 ~ 24

Ø25.4 / Ø25.48 ~ 50

1414.003.224.35

14.005.152.7213.103.703.5413.105.392.43

9.0(3.0 × 3 pcs.)WSYK160DA9

14.004.40

4.809.50

1290 × 900 × 33099

R410A

50Ø9.52

Ø15.885 / 20

1515

40.125.0 / 50.0

1034 × 450 × 48053

258

Ø25.4 / Ø25.4

3Ø 400V, 50Hz

3Ø 400V, 50Hz

2.50

3.18

55*2

8 ~ 60

1010.002.304.35

WPYA100LA

8.103.002.708.003.322.419.802.883.407.003.312.11

28.710.0 / 30.0

51*210.20

Additional refrigerant charge amount g/m

54.601.074.30

4.801.772.704.171.23

4.05

3.0(1.5×2 pcs.)WSYA050DA

4.311.363.16

5.16

14.39.0 / 18.3

3.38

1.782.28

6.501.634.00

5.602.242.505.401.613.355.102.322.20

3.0(1.5×2 pcs.)

6

WSYA065DA

18.610.0 / 23.3

7.25

5.592.052.73

1010.302.584.00

8.103.522.308.302.513.307.003.332.10

6.0(3.0×2 pcs.)WSYA095DA

27.216.7 / 35.0

10.40

64

40Ø9.52

Ø15.885 / 20

2020

AOYA30LBTL

2.20

830×900×33055*2

16.00

8.693.212.71

55

13

Ø9.52Ø15.885 / 20

2020

13.703.424.00

11.554.372.649.702.983.269.204.302.14

6.0(3.0×2 pcs.)WSYA128DA

36.725.0 / 50.0

13.70

1290×900×33098

50

AOYA45LBTL

3.35

*219.00

12.313.873.18

16

Ø9.52Ø15.885 / 20

2020

16.204.153.90

12.404.772.60

13.304.203.17 11.005.372.05

6.0(3.0×2 pcs.)WSYA155DA

44.425.0 / 50.0

17.10

55.5

105

40

AOY54LJBYL

3.40

1290×900×330

24.50

13.944.772.92

88.00

7.002.542.756.201.883.305.902.622.25

3.0(1.5×2 pcs.)WSYA080DA

8.2711.22

44

20Ø6.35

Ø15.885 / 15

1515

AOYA24LALL

6.392.342.73

1.70

22.914.3 / 28.3

578×790×31540*3

2.004.00

55

11

6.0(3.0 × 2 pcs.)

11.20 2.54 4.40 11.203.54 3.16 11.204.16 2.69 9.60 2.77 3.46 9.60 4.12 2.33

32.120.0 / 40.0

*2 56

14

6.0(3.0 × 2 pcs.)

14.00 3.25 4.30 14.00 4.51 3.10 14.00 5.47 2.56 12.00 3.50 3.42 12.00 5.32 2.26

40.125.0 / 50.0

*2

1Ø 230V, 50Hz

1Ø 230V, 50Hz

WSYG140DB6

52

92

10.8 13.721.0 24.0

-25 ~ 35

WOYK112LAT WOYK160LATWOYK140LATWOYG112LBT WOYG140LBT

*1

*1

*1

*1

*1

*1

*1

*1

*1

*1

*1. The values of heating capacity/power input/COP are based on measurement of EN14511 standard.

Usage environment, such as operation of the heating equipment, room temperature, and controller adjustments, may cause disparities between practically determined and these values.

*2. Sound pressure level measured at distance of 1m from the device and at a height of 1.5m above ground in free field

*3. Sound pressure level measured at distance of 5m from the device and at a height of 1.5m above ground in free field

Page 86: Fujitsu 2012 catalog

170

This solves your problems with distracting lifestyles smells and other stubborn smells.

*1. Compared to our Model ACS-24NVU Air Cleaner using urine (substituted with ammonia), food and raw garbage (fermented beans used as compound odour). However, approximately 50 times the deodorising capability (our company’s study) for faecal waste (skatol and compound odour). Tested with constantly emitted odour. Calculated from the fact that the balance ratio of concentration for the same generation volume with the concentration of odour intensity level 1 as 10 times is inversely proportional to the removal capability.*2. Test organization: Kitasato Research Center of Environmental Sciences. Checked in UV deodorant system. *3. Washing with water once a year is the standard when cleaned with a vacuum cleaner once a month. (The cleaning frequency can vary depending on the conditions of use in the home. Replacement may also be necessary, depending on the condition of use.)

Page 87: Fujitsu 2012 catalog

173172

Washable

1 2 3 4 5

Automatic deodorisationcapability regeneration

2 WORLD FIRST functions.

UV deodorant system

High Performance Verification Test Results

Removes permeated odours

The deodorising component*5 (weak ozone) discharged from the body decomposes and deodorises odours permeating the room from their source.

DASY30S

Automatic deodorisationcapability regeneration system

Powerfully removes odours by the world’s first deodorisation decomposition technology.Simultaneously displays air cleaning and bacteria elimination effects, and makes living more pleasant.

WirelessRemote

Controller

*1 *1

Odour intensity : 5. Very strong odour 4. Strong odour 3. Easily sensible odour 2. Weak odour but type of odour is sensed 1. Slightly sensible odour 0. No odour

00

:Home air cleaner ACS-24NUV :Natural loss

1

2

345

5 10 15

Pet, human waste odour

Concentration differenceapprox.

(Fujitsu General rate)150 times

Concentration differenceapprox.

(Fujitsu General rate)

*3 150 times

Raw garbage odour (Change of stray virus in 1m3 box)

:AIR DEODORISER DASY30S

0

1009080706050403020100

(%)

105 15 20 25

Comparison of deodorising performance Virus elimination rate

:AIR DEODORISER DASY30S

Odo

ur in

tens

ity

Odo

ur in

tens

ity

Viru

s su

rviv

al ra

te

(minute)(minute)

00

1

2

345

5 10 15(minute)

99.98% removed

*4

Image of filter regeneration by heating operation

Rem

oval

rate

(%)

Operation time (hours)

0

100

0 12 24 36

Change of removal rate when heating operation was performedChange of removal rate without heating operation30 minutes heating operation approximately every 12 hours

Recovering original deodorising ratio in 30 minutes

Large volume of ozone is generated by light (185nm). Ozone power decomposes odour molecules.

Powerful deodorisation &bacteria elimination by 3 wavelengths

Photo catalytic deodorisationOdour molecules are decomposed by illuminating a titanium oxide plate with light (254nm).

Ozone deodorisation

Bacteria eliminationBacteria and virus are repelled by light (185nm) having a bacteria elimination power 1600 times that of sunlight.

*2Deodorisation capability regenerated by heating

*3

Specifications

Odo

ur in

tens

ity

0

deodorising component1

2

345

Time elapsed (hours)0 1 2 3 4

Natural elimination

Deodorising effect of a piece of cloth permeated with the odour of 10 cigarettes6 stage odour intensity method (test room of 13.2m2)

*1. Home air deodorisation machine announced November 7, 2005. *2. Generates light of 3 wavelengths; ozone generation 185nm, bacteria elimination 254nm, and photo catalyst activation 365nm. *3. Compared to our Model ACS-24NVU Air Cleaner using urine (substituted with ammonia), food and raw garbage (fermented beans used as compound odour). However, approximately 50 times the deodorising capability (our company’s study) for faecal waste (skatol and compound odour). Tested with constantly emitted odour. Calculated from the fact that the balance ratio of concentration for the same generation volume with the concentration of odour intensity level 1 as 10 times is inversely proportional to the removal capability. *4. Test organization: Kitasato Research Center of Environmental Sciences. Checked in UV deodorant system. *5. Generates very weak ozone. However, the concentration is less than the volume existing in the natural state in forests, etc. The deodorising effect varies depending on the room size and amount of ventilation. *6. Test organization: Tested by Shinshu University using lice carcass, lice faeces, cat epidermis, dog epidermis, and orchard grass. *7. Washing with water once a year is the standard when cleaned with a vacuum cleaner once a month. (The cleaning frequency can vary depending on the conditions of use in the home. Replacement may also be necessary, depending on the condition of use.) • Photographs and illustrations are images. • Harmful substances (carbon monoxide, etc.) of tobacco cannot be removed.

Air cleaning capability

Air is cleaned by powerful dust collection.

Prefilter: Removes pet hair and large dust particles.Allergenic substance decomposition dust collection filter: Removes pollen, lice, and other allergenic substances*6

Dust Cat and dogepidermis

Pollen(Orchard grass)

Lice(Carcass, droppings)

Filter replacement unnecessary*7

All filters do not require replacement. Economical

Washable. Replacement unnecessary.1. Prefilter2. Allergenic substance decomposition dust collection filter

Automatic deodorisation capability regeneration. Maintenance-free3. Heater unit4. Compound metal oxidation catalyst honeycomb filter5. Special activated charcoal filter

VHz

m3/mindBWm3

220-24050/60

AUTO, QUIET, HIGH, HI-POWERAt minimum 0.8, at maximum 3.0At minimum 19, at maximum 45At minimum 11, at maximum 35

Non-woven fabric pleat filterUV ozone + compound honeycomb

Bacteria elimination lampCatalytic honeycomb filter: Automatic refreshingDust collection filter: Water washing refreshing

Gas sensorInverter

1274 x 653 x 215

6.4Floor installation (wall mounting bracket installable)

2Overcurrent prevention (current fuse)

Excessive temperature rise prevention (automatic reset thermostat)Excessive temperature rise prevention (temperature fuse)

Accessory

Model No. DASY30S

h

kg

m

mm

~33 *By amount of generation source

•Oxidation and decomposition capability is promoted by heating the filter for 30 minutes every 12 hours.

•Initial performance is maintained by removing odour molecules clinging to the filter.

Power consumptionApplicable floor spaceDust collection functionDeodorising methodBacteria elimination method

Filter life

SensorMotor driveOff timerProduct outside dimensionsProduct weightInstallationPower cord length

Safety devices

Remote controller

Operating soundAir flowOperation modes

Rated voltage

Page 88: Fujitsu 2012 catalog

175174

Feature Explanation

Comfortable function Feature summary

Com

fort

able

func

tion

Con

veni

ent f

unct

ion

Cle

an fu

nctio

n

Double swing automaticComplex swing action of flaps enables automatically to swing both horizontal and vertical directions.

Up / down swing flapsThe up/down flaps automatically swing up and down.

Auto restartIn the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once the power supply is restored.

Auto-changeoverThe unit automatically switches between heating and cooling modes based on your temperature setting and the room temperature.

10°C HEAT operationThe room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.

Automatic air flow adjustmentThe micro-computer automatically adjusts the air flow effectively to follow the changes of room temperature.

Convenient function

Sleep timerThe micro-computer gradually changes the room temperature automatically to afford a comfortable night's sleep.

ON-OFF timerON-OFF timer can be set to operate once.

Program timerThis digital timer allows selection of one of four options: ON, OFF, ON OFF or OFF ON.

Weekly timerDifferent on-off times can be set for each day.

Weekly + setback timerWeekly + Setback timer can set temperature for two times spans and for each day of the week.

Filter signIndicates the filter cleaning period by lamp.

Economy modeLimits the maximum operation current, and performs operation with the power consumption suppressed.

Powerful modeOperation at maximum air flow and compressor speed, and quickly makes the room comfortable.

Low Noise ModeSound noise level of outdoor unit can be selected.

Connectable fresh air duct

Fresh air intakeFresh air can be taken in by a fan which can be connected using external control unit.

Connectable distributing duct

Energy saving modeThis mode raises the set temperature slightly in the cooling mode and lowers the set temperature in the heating mode to economically control the operation of the unit.

Automatic filterThe filter is automatically cleaned after the time is set for the air conditioner.

UV filter cleanerUV (ultraviolet rays) suppresses the growth of mold and germs inside the indoor unit.

The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.

Apple-catechin filterFine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol extracted from apples.

Coil dry

Washable panel

Clean function

Long-life ion deodorization filter

The indoor unit can be dried to prevent the growth of mold and bacteria.

i-PAM control models

V-PAM control models

Up / down swing flaps

Wall Mounted

FloorCeiling Wall

Compact Cassette / Cassette

Floor/Ceiling UniversalCeiling

Slim Duct

Compact Duct / Medium Static Pressure Duct

High Static Pressure Duct

Double swing automatic

Automatic air flow adjustment

Auto restart

Auto-changeover

10°C heat operation

Connectable distributing duct

Connectable fresh air duct

Fresh air intake

Economy mode

Sleep timer

On-off timer

Program timer

Weekly timer

Weekly + setback timer

Filter sign

Automatic filter cleaner

UV filter cleaner

Long-life ion deodorization filter

Apple-catechin filter

Coil dry

Washable panel

AWYZ14LB/18LB/24LB

ASYG09LT/12LT

ASYG07LU/09LU/12LU/14LU

ASYG18LF/24LF/30LF

ASYG07LE/09LE/12LE/14LE

ASY7UB/9UC/12UC

ASY18UB/24UB/30UB

AGYF09LA/12LA/14LA

AUYG12LVLB/14LVLB/18LVLB/AUYF24LB

AUY18UB

AUYA30LB/36LB/45LC/54LC

AUY25UU/30UU/36UU/45UU/54UU

ABYG18LVLB/ABYF24LB

ABY18UB/24UB

ABYA30LB/36LB/45LC/54LC

ABY30UB/36UB/45UB/54UB

ARYG12LLTB/14LLTB/18LLTB

ARY18UU

ARYF24LB/ARYA30LB/36LB/45LC

ARY25UU/30UU/36U(1)/36UU/45UU

ARYC45LC/54LC

ARY60UU

ARY90TL

(12/14/18) (18)

: Optional function

Energy saving mode

Human sensor

Low Noise modeLow noise

Powerful modePOWERFULPOWERFULPOWERFUL

Human sensorHuman sensor catches movements of people in a room.

Low noise

POWERFULPOWERFULPOWERFUL

(45/54) (45) (45)