from the dawn of excellence emanates the high noon of ......• awe can supply submersible flat...
TRANSCRIPT
From the dawn of Excellenceemanates the high noon of Performance
Gelco Electronics is a full service electronic company that manufactures superior quality electronic control and
switchgear products & measuring equipment alongwith power saving devices. Established in 1984, the company
is located in the industrial belt of Ahmedabad, which is one of the fastest developing metropolitan cities of India.
Our state of the art manufacturing facility with its prolific R&D centre in conjunction with our strict adherence
to quality control and safety norms has ensured an impressive growth record in these past three decades. More
importantly, it has gained a reputation of excellence & dependability from its clients.
After achieving wide success in the Indian market, Gelco is now spreading its wings internationally. To attain the
same level of success globally, Gelco has conducted extensive research in each market to understand their electrical
equipment’s needs and subsequently, developed specific products for them that are longlasting, efficient and safe.
R a n g e o f PR o d u c t s
• Single Phase Motor Starters & Control Panel• Three Phase DOL Motor Starters & Control Panel• Three Phase Star Delta Motor Starters & Control Panel• Duty Stand by Panel for Dual Pumps• Panel Accessories
a P P l i c at i o n s
• Home• Agriculture• Industries
1
note:• A wide range of products which can be offered on request.• We can supply starter / panel / A.T.S. panel / 60 Hz starter / panel as per customer’s specifications.• A wide range of lighting products which can be offered on request.• We can supply submersible flat & round, PVC & rubber, 3 core and 4 core cable.• We can supply submersible pumpsets, monoblock pumpsets, industrial pumpset, electric induction motors &
UPVC column pipes, etc.• Due to continuous R & D, specifications, construction of materials, design, outlook, colour & finishing, etc. can be
changed without intimation.
indeXTopic Page
Single Phase Motor Starter 1-2
Single Phase Electronic Control Panel 3
Three Phase Dol Motor Starter 4-5
Three Phase Dol Motor Starter - Metal Body 6
Three Phase Star Delta Motor Starter 7
Three Phase Dol Electronic Control Panel 8
Three Phase Star Delta Electronic Control Panel 9
Duty Stand By Panel For Dual Pumps Operation 10
Voltage Stabilizer 11
Auto Switch 12
Single Phase Starter 13
A.C. Switch 14
Phase Failure Relay 15-16
Motor Protection Relay 17
Pump Protection Relay 18
Analog Timer 19-20
Digital Timer 21
Digital Time Switch 22
Earth Leakage Relay 23-24
Earth Leakage Circuit Breaker 25
Panel Meters 26
Automatic Light Controller 27
Single Phasing Preventer With Water Level Guard 28
Water Level Controller 29-30
(1.1) | GSS-MCB
sa l i e n t fe at u R e s :• Easy to operate
• Overload protection through MCB
• Economical solution
• Enclosure made from engineering grade plastic (ABS)
a P P l i c at i o n:Only for Oil Filled Pump set
Va R i a n t s:
Motor H.P. Run Capacitor MCB
0.75 H.P. 0 + 25 MFD 10 Amp.
1.0 H.P. 0 + 36 MFD 10 Amp.
2.0 H.P. 0 + 50 MFD 16 Amp.
3.0 H.P. 0 + 72 MFD 25 Amp.
(1.2) | GSS-RE
sa l i e n t fe at u R e s :• Electronic start/stop push buttons
• Electronic overload protection
• High voltage protection above 280 V AC
• Low voltage protection below 150 V AC
• Engineering grade plastic enclosure (ABS)
• Facility to connect Gelco Water Level Controller Adaptor
(LLC-001D)
a P P l i c at i o n:Only for oil filled pump set
Va R i a n t s:
Motor H.P. Run Capacitor Current Range
0.75 H.P. 0 + 25 MFD 4 - 10 Amp.
1.0 H.P. 0 + 36 MFD 4 - 10 Amp.
2.0 H.P. 0 + 50 MFD 10 - 16 Amp.
3.0 H.P. 0 + 72 MFD 10 - 16 Amp.
SINGLE PHASE MOTOR STARTERInput supply voltage : 230V, AC ±20% | Output supply voltage : 230V, AC ±20%
2 3
SINGLE PHASE ELECTRONIC CONTROL PANEL
(2.1) | MCB WS
sa l i e n t fe at u R e s :• In built digital volt and amp. meter (GELCO ACCURA)• Easy to operate• Powder coated sheet metal enclosure
a P P l i c at i o n:• Submersible/monoblock pump set
Va R i a n t s:
MCB Start Capacitor Run Capacitor
10 100/120 MFD 36 MFD
20 150/200 MFD 36 + 36 MFD
25 200/250 MFD 36 + 36 MFD
25 200/250 MFD 50 + 50 MFD
(2.2) | DCP - 7201
sa l i e n t fe at u R e s :• Fully automatic electronic start/stop facility• Digital micro controller based technology• Higher accuracy• Digital indication of fault condition• Precise overload protection (over current)• Precise over voltage protection• Precise under voltage protection• Dry run protection
• With programmable parameters• In built auto ON/OFF timer (1 - 240 Minutes)• Powder coated sheet metal enclosure
a P P l i c at i o n:Submersible/Monoblock pumpset for drawing water in residence,
commercial, farming, gardening
Va R i a n t s:
Motor H.P. Start Capacitor Run Capacitor Current Range
1.0 H.P. 100/120 MFD 36 MFD 4 - 20 Amp
1.5 H.P. 150/200 MFD 36 + 36 MFD 4 - 20 Amp
2.0 H.P. 200/250 MFD 50 + 50 MFD 15 - 30 Amp
(1.3) | DCP - RE
sa l i e n t fe at u R e s :• Electronic start/stop push button
• Inbuilt digital volt and amp meter
• Latest micro controller based technology for better accuracy
• Precise protection against over load (over current)
• Precise protection against high voltage
• Precise protection against low voltage
• Dry run protection (optional)
• Digital indication of fault condition
• Engineering grade plastic enclosure (ABS)
• Facility to connect GELCO Water Level Controller Adaptor
(LLC-001D)
• With programmable parameters
a P P l i c at i o n:Only for oil filled pumpset
Va R i a n t s:
Motor H.P. Run Capacitor Current Range
1.0 H.P. 36 MFD 2-16 Amp.
1.5 H.P. 50 MFD 2-16 Amp.
2.0 H.P. 72 MFD 2-16 Amp.
Input supply voltage : 230V, AC ±20% Output supply voltage : 230V, AC ±20%
SINGLE PHASE MOTOR STARTERInput supply voltage : 230V, AC ±20% | Output supply voltage : 230V, AC ±20%
4 5
THREE PHASE DOL MOTOR STARTER Input/Output voltage : 415V, AC ±20% , 50Hz.
(3.1) | GTWsa l i e n t fe at u R e s :• Current sensing unit• Inverse time current characteristics• Electronic start/stop push button facility• Electronic overload protection• Over voltage protection• Under voltage protection• Dry run protection (optional)• Phase failure protection• Reverse phasing protection• Engineering grade plastic enclosure (ABS)• Can be used up to 7.5Hp DOL motor/pumps• Other Models are also available on request
a P P l i c at i o n:• DOL submersible pump set for drawing water in residence,
commercial, farming, gardening• Induction motor in industries
Va R i a n t s:
Type Current Range
GTW-304 2 - 5 Amp.
GTW-305 4 - 10 Amp.
GTW-306 8 - 20 Amp.
(3.2) | GTVsa l i e n t fe at u R e s :• All facilities available as per GTW• Current and voltage sensing unit• Over voltage protection• Under voltage protection• Low/High cut out• Facility to connect GELCO Water Level Controller
(Model LLC-001/LLC-001D)• Can be used up to 7.5Hp DOL motor/pumps
a P P l i c at i o n:• DOL submersible pump set for drawing water in residence,
commercial, farming, gardening• Induction motor in industries
Va R i a n t s:
Type Current Range
GTV-304 2 - 5 Amp.
GTV-305 4 - 10 Amp.
GTV-306 8 - 20 Amp.
(3.3) | GTAsa l i e n t fe at u R e s :• All facilities available as per GTV• Additional facility to put the Motor/Pump ‘ON’
automatically after power supply resumption• One minute time delay before start• Can be used up to 7.5Hp DOL motor/pumps
a P P l i c at i o n:• DOL submersible pump set for drawing water in residence,
commercial, farming, gardening• Induction motor in industries
Va R i a n t s:
Type Current Range
GTA-304 2 - 5 Amp.
GTA-305 4 - 10 Amp.
GTA-306 8 - 20 Amp.
(3.4) | DCP - 304
sa l i e n t fe at u R e s :• Using latest micro controller based technolgy• Electronic Start/Stop push button• Inbuilt digital volt & amp meter• Digital display of fault condition• Electronic overload protection• Over voltage protection• Under voltage protection• Dry run protection• With programmable parameters• Phase failure protection• Reverse phasing protection• Facility to connect GELCO Water Level Controller Adaptor (LLC-001D)• Engineering grade plastic enclosure (ABS)• Can be used up to 7.5Hp DOL motor/pumps
a P P l i c at i o n:• Three phase DOL submersible/monoblock pump setfor drawing water in residence, commercial, farming, gardening
Va R i a n t s:
Current Range
2 - 20 Amp.
6 7
THREE PHASE DOL MOTOR STARTER - METAL BODYInput voltage : 415 V ± 20% VAC I Output voltage: 415 V ± 20% VAC
THREE PHASE STAR DELTA MOTOR STARTERInput voltage : 415 V ± 20% VAC Output voltage: 415 V ± 20% VAC
(4.1) | GEW-1 (DOL)
sa l i e n t fe at u R e s :• Easy to operate• Powder coated sheet metal enclosure• Thermal overload protection
a P P l i c at i o n:• DOL motors for drawing water in residence, commercial, farming, gardening
Va R i a n t s:
Motor H.P. Overload Range
5.0 H.P. 6 – 10 A
7.5 H.P. 9 – 14 A
10 H.P 13 – 21 A
(4.2) | GLO-1 (DOL)
Va R i a n t s:
Motor H.P. Overload Range
3.0 H.P. 6 – 10 A
5 H.P. 6 – 10 A
7.5 H.P 10 - 16 A
(4.3) | GLO-1.5 / 2 / 3 (DOL)
Va R i a n t s:
Motor H.P. Overload Range
10 H.P. 13 - 21 A
15 H.P. 20 - 32 A
20 H.P. 20 - 32 A
30 H.P. 28 - 42 A
(5.1) | GLO-FASD / SA-Metal Body
Va R i a n t s:
Type Motor H.P. Overload Range
GLO-1 3 H.P. 6 - 10 A
GLO-1 4 H.P. 6 - 10 A
GLO-1 5 H.P. 6 - 10 A
GLO-1 6 H.P. 6 - 10 A
GLO-1 7.5 H.P. 6 - 10 A
GLO-1 10 H.P. 6 - 10 A
GLO-1 12 H.P. 10 - 16 A
GLO-1.5 15 H.P. 13 - 21 A
GLO-2 20 H.P. 20 - 32 A
GLO-2 25 H.P. 20 - 32 A
GLO-3 30 H.P. 28 - 42 A
GLO-3 40 H.P. 28 - 32 A
8 9
THREE PHASE DOL ELECTRONIC CONTROL PANEL
(6.1) | DIGI : DOLsa l i e n t fe at u R e s :• Inbuilt digital volt & amp meter (AVM-101)• With bright LED phase indication with flash• Automatic rotational phase to phase voltage indication• Thermal overload protection• Short circuit protection through MCB• Over voltage protection• Under voltage protection• Phase failure protection• Auto start after resumption of supply• Powder coated sheet metal encloser
a P P l i c at i o n:• For 3 phase DOL submersible/monoblock pump set for irrigating
remote farms, unreachable/vast gardening area
Va R i a n t s:
Relay Range
4 - 6.5 Amp. 6 - 10 Amp. 9 - 14 Amp. 13 - 21 Amp.
(6.2) | DCP-9603sa l i e n t fe at u R e s :• Using latest micro controller based technolgy• Electronic start/stop push button• Inbuilt digital volt & amp meter• Digital display of fault condition• Electronic overload protection• Over voltage protection• Under voltage protection• Dry run protection• With programmable parameters• Phase failure protection• Reverse phasing protection• Inbuilt auto ON/OFF timer• Facility to connect GELCO Water Level Controller Adaptor (LLC-001D)• Remote ON/OFF• Powder coated sheet metal enclosure (IP-55)• Digital display facility on faulty connection
a P P l i c at i o n:• Three phase DOL submersible/monoblock pump set
for drawing water in residence, commercial, farming, gardening
Va R i a n t s:
Current Range
2 - 5 Amp. 4 - 10 Amp. 8 - 20 Amp.
Input voltage : 415 V ± 20% VAC Output voltage: 415 V ± 20% VAC
THREE PHASE STAR DELTA ELECTRONIC CONTROL PANEL
(7.1) | DCP-9613sa l i e n t fe at u R e s :• Fully automatic star delta starter• Using latest micro controller based technology• Inbuilt digital volt /amp meter• Electronic overload protection• Over voltage protection• Under voltage protection• Dry run protection• Current sensing unit• Phase failure protection• Reverse phase protection• With programmable parameters• Inbuilt auto ON/OFF timer• Powder coated sheet metal enclosure (IP55)• Easy to maintain detachable spares• Remote ON/OFF• Facility to connect GELCO Water Level Controller Adaptor (LLC-001D)• Digital display facility on faulty connection
a P P l i c at i o n:• For three phase star delta motors used in farms, pumping
station, municipal corporation
Va R i a n t s:
Motor H.P. Overload Range Motor H.P. Overload
Range
7.5 H.P. 8 - 20 Amp. 20.0 H.P. 16 - 40 Amp.
10.0 H.P. 8 - 20 Amp. 25.0 H.P. 24 - 60 Amp.
12.5 H.P. 16 - 40 Amp. 30.0 H.P. 24 - 60 Amp.
15.0 H.P. 16 - 40 Amp. 35.0 H.P. 32 - 80 Amp.
Input voltage : 415 V ± 20% VAC Output voltage: 415 V ± 20% VAC
10 11
VOLTAGE STABILIZER
(9.1) | SERVO
s e R V o co n t R o l l e d Vo lta g e sta b i l i z e R
• I/P: 170V to 270V (For 1 Phase)
360V to 460V (For 3 Phase)
• O/P: 230V AC + 1% for 1 Phase
415V AC + 1% for 3 Phase
• Also available in customised I/P and O/P voltage range
• Capacity: Up to 400 KVA
• Cooling: Air cooled
Oil cooled
• Balance or unbalance type
• Display parameter: Digital volt and amp. meter
• Protection: Over voltage, under voltage, overload &
single phasing
(9.2) | VIOLTEÉ
Model Input Range Output Range
Time Delay Application
GDMS-20 170V AC – 270V AC 220V AC ± 10% 5 Sec. Television/
DTH
GDMS-50 170V AC – 270V AC 220V AC ± 10% 3 Min. Refrigerator
DLC-50 170V AC – 270V AC 210V AC – 230V AC 10 Sec. Computer
(9.3) | VIOLTEÉ emax
Model Input Range Output Range Time Delay
GDMS - 300 170V AC – 270V AC 220V AC ± 10% 3 Min.
GDMS - 400 170V AC – 270V AC 220V AC ± 10% 3 Min.
GDMS - 500 170V AC – 270V AC 220V AC ± 10% 3 Min.
DUTY STANDBY PANEL FOR DUAL PUMPS OPERATION
(8.1) | DCP-9603 DP
sa l i e n t fe at u R e s :• Volt current and other fault conditions display
• Over voltage, under voltage and dry run protection
• Pump run and trip indication
• Singe phasing, current and voltage sensing protection
• Selector/toggle switch for pump-1 and pump-2
or alternate operation
• Manual/auto ON/OFF
• Sheet metal enclosure with IP-55 protection
a P P l i c at i o n:• Suitable for booster pumps application
Va R i a n t s:• Up to 35 HP - DOL or FASD
12 13
AUTO SWITCH
(10.1) | Auto Switch
sa l i e n t fe at u R e s :• Voltage sensing unit
• Phase failure protection
• Reverse phasing protection
• Engineering grade plastic enclosure (ABS)
• Auto ‘ON’ after resumption of power supply
• Panel mountable
te c h n i c a l s P e c i f i c at i o n s:• Aux supply voltage: 415V AC +/- 20 % , 50 Hz
• Phase unbalance volt: 45 V +/- 5 V
• Start time delay: 1 Minute
• Output: 1 C/O, 6 Amp (Resi.) @ 230 VAC
a P P l i c at i o n:• For MCC panels of water pump at remote farms, unattainable area
SINGLE PHASE STARTER
(10.2.1) | GSW
sa l i e n t fe at u R e s :• I/P: 230 V, 1phase, AC supply• ABS body• High/Low voltage protection• Over load protection• Variable current (Amp.) setting
Va R i a n t s:
Type Current Range:
GSW-104 2 - 5 Amp.
GSW-105 4 - 10 Amp.
GSW-106 8 - 14 Amp.
GSW-107 10 - 16 Amp.
GSW-108 14 - 22 Amp.
(10.2.2) | GSW-T
sa l i e n t fe at u R e s :• I/P: 230 V, 1phase, AC supply• ABS body• High/Low voltage protection• Over load protection• Time delay facility• Variable current/Amp setting• Auto/manual start facility
Va R i a n t s:
Type Current Range:
GSW-T-104 2 - 5 Amp.
GSW-T-105 4 - 10 Amp.
GSW-T-106 8 - 14 Amp.
GSW-T-107 10 - 16 Amp.
GSW-T-108 14 - 22 Amp.
Input voltage : 230 V, AC ± 10% Output voltage: 230 V, AC ± 10%
14 15
A.C. SWITCH
(10.2.3) | AaCcSvch
te c h n i c a l s P e c i f i c at i o n s:• Input voltage: 85V Ac To 300V Ac• Current range: 2A to 16A• High voltage protection : Above 280V• High voltage cut in: Below 260V• Low voltage protection : Below 160V• Low voltage cut in : Above 175V• Over load protection programmable range 2A to 16A (auto/manual)• Time delay : 60 sec. (1minute) after resumption of power supply• Switching device : Relay• Display of live voltage and live current by seven segment LED• Display total run time of your load in hour
a P P l i c at i o n:• Air-conditioner, television, refrigerator, domestic flour mill
PHASE FAILURE RELAY
(10.3.1) | PFR-104
sa l i e n t fe at u R e s :• Micro controller based technology
• Slim in size
• Higher accuracy
• Voltage sensing unit
• Phase failure protection
• Reverse phasing protection
• Engineering grade plastic enclosure (ABS)
• DIN rail mountable
te c h n i c a l s P e c i f i c at i o n s:• Aux supply voltage: 415V AC +/- 20 % , 50 Hz
• Phase unbalance volt: 45V +/- 5V
• Tripping delay: 4 to 7 sec
• Output: 1 C/O, 6 Amp (Resi.)
a P P l i c at i o n:• For MCC panels of water pumps, generators, compressors
(10.3.2) | PFR-105
sa l i e n t fe at u R e s :• Micro controller based technology
• Slim in size
• Higher accuracy
• Voltage sensing unit
• Phase failure protection
• Engineering grade plastic enclosure (ABS)
• DIN rail mountable
te c h n i c a l s P e c i f i c at i o n s:• Aux supply voltage: 415 VAC +/- 20 % , 50 Hz
• Phase unbalance volt: 45V +/- 5V
• Tripping delay: 4 to 7 sec
• Output: 1 C/O, 6 Amp (Resi.)
a P P l i c at i o n:• For MCC panels of water pumps, generators, compressors
16 17
MOTOR PROTECTION RELAYPHASE FAILURE RELAY
(10.4.1) | MGR-101sa l i e n t fe at u R e s :• Current sensing unit• Inverse time current characteristics - 2 sec.• Reverse phase protection• Micro controller based technology• Electronic over load protection• Low/High voltage protection• Phase failure protection• Engineering grade plastic enclosure (ABS)• DIN rail & panel mountable
te c h n i c a l s P e c i f i c at i o n s:• Aux. supply voltage 415 +/- 20 % VAC• Over voltage: 120% +/- 5V of supply voltage• Under voltage : 80 % +/- 5V of supply voltage• Current unbalance phase-phase: 50 % of full scale current• Tripping delay: 4 to 7 sec.
a P P l i c at i o n:• MCC panels of water pump
R e l ay R a n g e :CT Unit CTU-05 CTU-10 CTU-20 CTU-40 CTU-80
Current Range (Amp) 2-5 A 4-10 A 8-20 A 16-40 A 32-80 A
(10.4.2) | MGR-102sa l i e n t fe at u R e s :• Current & voltage sensing unit• Inverse time current characteristics - 2 sec.• Micro controller based technology• Electronic over load protection• Over voltage protection• Under voltage protection• Phase failure protection• Reverse phase protection• Engineering grade plastic enclosure (ABS)• DIN rail & panel mountable
te c h n i c a l s P e c i f i c at i o n s:• Aux. supply voltage 415 +/- 20 % VAC• Over voltage: 120% +/- 5V of supply voltage• Under voltage : 80 % +/- 5V of supply voltage• Current unbalance phase-phase: 50 % of full scale current• Voltage unbalance phase-phase : 45 +/- 5V• Tripping delay: 4 to 7 sec.
a P P l i c at i o n:• MCC panels of water pump
R e l ay R a n g e :CT Unit CTU-05 CTU-10 CTU-20 CTU-40 CTU-80
Current Range (Amp) 2-5 A 4-10 A 8-20 A 16-40 A 32-80 A
(10.3.3) | PFR-106
sa l i e n t fe at u R e s :• Micro controller based technology• Slim in size• Higher accuracy• Voltage sensing unit• Phase failure protection• Over voltage protection• Under voltage protection• Reverse phasing protection• Engineering grade plastic enclosure (ABS)• DIN rail mountable
te c h n i c a l s P e c i f i c at i o n s:• Aux supply voltage: 415V AC +/- 20 % , 50 Hz• Phase unbalance volt: 45V +/- 5V• Over voltage: above 480 VAC• Under voltage: below 320V• Tripping delay: 4 to 7 sec• Output: 1 C/O, 6 Amp (Resi.)
a P P l i c at i o n:• For MCC panels of water pumps, generators, compressors, lift
18 19
PUMP PROTECTION RELAY
(10.5.1) | PGR-101sa l i e n t fe at u R e s :• Current sensing unit• Inverse time current characteristic - 2 sec.• Micro controller based technology• Electronic over load protection• Over voltage protection• Under voltage protection• Phase failure protection• Reverse phase protection• Dry run protection (prodless)
te c h n i c a l s P e c i f i c at i o n s:• Aux. supply voltage 415 +/- 20 % VAC• Over voltage: 120% +/- 5V of supply voltage• Under voltage : 80 % +/- 5V of supply voltage• Current unbalance phase-phase: 50 % of
full scale current• Dry run : 40 % to 80 % of overload setting• Tripping delay: 4 to 7 Sec.• Output 1 c/o, 6 Amp. (Resi) at 230VAC
a P P l i c at i o n:• MCC panels of water pump in hilly regions
R e l ay R a n g e :CT Unit CTU-05 CTU-10 CTU-20 CTU-40 CTU-80
Current Range (Amp) 2-5 A 4-10 A 8-20 A 16-40 A 32-80 A
(10.5.2) | PGR-102sa l i e n t fe at u R e s :• Current & voltage sensing unit• Inverse time current characteristics - 2 sec.• Micro controller based technology• Electronic over load protection• Over voltage protection• Under voltage protection• Phase failure protection• Reverse phase protection• Engineering grade plastic enclosure (ABS)• DIN rail & panel mountable
te c h n i c a l s P e c i f i c at i o n s:As per PGR-101Voltage unbalance phase to phase : 45+ 5V
a P P l i c at i o n:MCC panels of water pump
R e l ay R a n g e :CT Unit CTU-05 CTU-10 CTU-20 CTU-40 CTU-80
Current Range (Amp) 2-5 A 4-10 A 8-20 A 16-40 A 32-80 A
ANALOG TIMER
(10.6.1) | AC-22
sa l i e n t fe at u R e s :• Micro controller based technology• Cyclic timer• Easy to programme, through dial on front• DIN rail mountable• Engineering grade plastic enclosure (ABS)
te c h n i c a l s P e c i f i c at i o n s:• Supply: 110/230V AC ± 20% 50 Hz, 12/24V AC/DC• Output: 2 C/O relay (5A @ 230 VAC)• Control action: cyclic• Time range: 1-10 sec /min/hr. selectable through DIP switch• Reset: power on reset
a P P l i c at i o n:• MCC panels for water pump, compressor, generator,
airconditioner
(10.6.2) | AS-22
sa l i e n t fe at u R e s :• Micro controller based technology• Single action timer• Delay ON/ OFF timer (Selectable)• Easy to programme with the help of dial in front• DIN rail mountable• Engineering grade plastic enclosure (ABS)
te c h n i c a l s P e c i f i c at i o n s:• Supply: 110/230V AC ± 20% 50 Hz, 12/24V AC/DC• Output: 2 C/O Relay (5A @ 230 VAC)• Control action: selectable delay ON/OFF• Time range: 1/3/10/30 sec/min/hr. selectable through DIP Switch• Reset: power on reset
a P P l i c at i o n:• MCC panels for water pump, compressor, generator
20 21
ANALOG TIMER
(10.6.3) | AS-21
sa l i e n t fe at u R e s :• Micro controller based technology• Single action timer• Delay ON/OFF timer (factory set)• Higher accuracy• Easy to programme with the help of dial in front• DIN rail mountable• Engineering grade plastic enclosure (ABS)
te c h n i c a l s P e c i f i c at i o n s:• Supply: 230/415V AC ± 20% 50 Hz• Output: 1 C/O relay (5A @ 230 VAC)• Control Action: delay ON/ delay OFF• Time range: 0-60 sec• Reset: power on reset
a P P l i c at i o n:• MCC panels for water pump, compressor, generator, airconditioner
(10.6.4) | SD-22
sa l i e n t fe at u R e s :• Micro controller based technology• Star delta timer• DIN rail mountable• Higher accuracy• Easy to programme• Engineering grade plastic encloser (ABS)
te c h n i c a l s P e c i f i c at i o n s:• Supply: 110/230/415V AC ± 20% 50 Hz• Output: 2 No. 1 C/O (230V AC, 6A)• Time range: y run up time 30/60 sec y to
Δ change over time 30-100m sec• Reset: Power on reset
a P P l i c at i o n:• MCC panels for Star Delta pump set
DIGITAL TIMER
(10.6.1) | DT-48
te c h n i c a l s P e c i f i c at i o n s:• Supply: 85V-265V AC, 50 Hz• Output: 2 C/O relay (5A @ 230 VAC)• Control action: selectable Delay On/Off & Cyclic• Time range: 0-99.9 hr./min./sec.• Display: 0.4” seven segment LED• Accuracy: ± 0.01% of FSD
(10.6.2) | DT-21
te c h n i c a l s P e c i f i c at i o n s:• Supply voltage: 85V AC-265V AC, 50 Hz• Output: relay NO-C-NC• Relay contact rating: 5A/230V AC resistive• Modes: Delay on, delay off
Cyclic C1: (relay ON @ power ON)
Cyclic C2: (relay OFF @power ON)• Display: 2 digit 0.39” (7 segment LED)• Accuracy: 0.01% of set time ± 1 display
a P P l i c at i o n:• Processing industries
(10.6.3) | DOT - 101
sa l i e n t fe at u R e s :• Delayed off timer• Compact size• Body made from black colour, industrial plastic materials (ABS)• Easily programmable• Simple installation
te c h n i c a l s P e c i f i c at i o n s:• Input supply: 230V AC, 50 Hz, 1Ø• Output: 230V AC, 50 Hz, 1Ø• Output capacity: 6A, 230V (Resi.)• Time range: 5 to 40 min. (instep of 5 min/step)
a P P l i c at i o n:• Exhaust fan• Any application where delayed off time is required
22 23
EARTH LEAKAGE RELAY
(10.8.1) | ELR-101
sa l i e n t fe at u R e s :• High precision
• Surface mountable (DIN Standard)
• Parameters are settable through knob in front panel
• Engineering grade plastic enclosure (ABS)
• With CBCT
te c h n i c a l s P e c i f i c at i o n s:• Auxiliary supply: 110/230/415v, 50 HZ
• Relay contact: 1 C/O contact with 6 Amp. (Resi.)
• Leakage current range:
30 to 100 mA
0.1 to 1 Amp
0.5 to 5 Amp
• Reset: Manual
• Operating temp. : -5°C to 60°C
• CBCT : 70,100,200,300 & 400mm
a P P l i c at i o n:Distribution panels for hotels, commercial complex,
residential blocks, industrial complex, mining industry
DIGITAL TIME SWITCH
(10.7.1) | DTS-502
sa l i e n t fe at u R e s :
• Micro controller based technology
• On/Off time is programmable
• 10 no. of programme for On/Off
• Display of real time clock
• LED display for unit On
• Easy to programme
• Engineering grade plastic enclosure (ABS)
te c h n i c a l s P e c i f i c at i o n s:
• Input supply : 230 +/- 20 % VAC
• Output supply : 230 +/- 20 % VAC
• Capacity : 20 Amp at 230 VAC (Resi.)
a P P l i c at i o n:
Water pump, street lights
(10.7.2) | DTS-601
sa l i e n t fe at u R e s :• Micro controller based technology
• On/Off time is programmable
• 10 no. of programme for On/Off
• Display of real time clock
• LED display for unit On
• Easy to programme
• Engineering grade plastic enclosure (ABS)
te c h n i c a l s P e c i f i c at i o n s:• Input supply : 415 +/- 20 % VAC
• Output : potential free 1 contact, 6 Amp at 230 VAC (Resi.)
a P P l i c at i o n:• Water pump, street lights
24 25
(10.8.2) | ELR-9601
sa l i e n t fe at u R e s :• Micro controller based technology
• Higher precision
• Flush mountable (92x92)
• Digital display of leakage current
• Parameters are programmable
• Engineering grade plastic enclosure (ABS)
• With CBCT
te c h n i c a l s P e c i f i c at i o n s:• Supply voltage : 85-265V AC, 50/60 Hz
• Relay contact : 1 change over
• Potential free contact
• Positive safety output (relay will energies on fault)
• Contact rating: 6A at 230V AC / 30V DC
• Leakage current range :
30mA - 300mA
50mA - 999mA
150mA - 3A
250mA - 5A
500mA - 10A
• Trip time set: 00.1 to 10 sec.
• Display : Digital 7seg. LED display
• Operating temp. : -5°c to 60°c
• CBCT 70, 100, 200, 300 & 400mm
a P P l i c at i o n:Distribution panels for hotels, commercial complex, residential
blocks, industrial complex, mining industry
EARTH LEAKAGE CIRCUIT BREAKER
(10.9.1) | EL+MCB
sa l i e n t fe at u R e s :
• Load current rating : 16A / 25A / 32A
• System voltage: 230V AC, 1 phase, 50Hz
• Sensitivity : 3-50 mA
• Tripping time: <30 ms.
• High/low voltage cut off
• Overload – short circuit protection
a P P l i c at i o n:Protection against shock and leakage current
EARTH LEAKAGE RELAY
26 27
(10.10) | AVM-101
sa l i e n t fe at u R e s :• Micro controller based technology
• Inbuilt C.T.
• Indicates phase to phase voltage
• Indicates system current
• Indication for phase through high bright LED
• Rotating voltage indication at fixed interval for different phase to phase
• Surface mountable (DIN standard)
te c h n i c a l s P e c i f i c at i o n s:• Aux. Supply : 415 +/- 20 % VAC
• Amp. Range : 4-40 Amp, 10-100 Amp
a P P l i c at i o n:Control panels for housing, water pumps, industries,
residential complex, etc.
PANEL METERS
(10.11.1) | AUTOPHOTO
Type AMPR PHASE APPLICATION
ALC – 6 ( I ) 1 6 Amp 1 Phase Indoor application
ALC – 10 ( I ) 1 10 Amp 1 Phase Indoor application
ALC – 10 ( O ) 1 10 Amp 1 Phase Outdoor application
ALC – 25 ( I ) 1 25 Amp 1 Phase Indoor application
ALC – 25 ( O ) 1 25 Amp 1 Phase Outdoor application
ALC – 16 ( O ) 3 16 Amp 3 Phase Outdoor application
ALC – 32 ( O ) 3 32 Amp 3 Phase Outdoor application
ALC – 63 ( O ) 3 63 Amp 3 Phase Outdoor application
AUTOMATIC LIGHT CONTROLLER
28 29
SINGLE PHASING PREVENTER WITH WATER LEVEL GUARD
(10.12.1) | SWG
sa l i e n t fe at u R e s :• Phase failure relay with dry run protection (with prod)
• Voltage sensing unit
• Over voltage protection
• Under voltage protection
• Engineering grade plastic (HIPS) enclosure
• Panel mountable
• Available with S.S. Sensor
te c h n i c a l s P e c i f i c at i o n s:• Aux Supply: 415 +/- 20 % VAC, 50 Hz
• Output : 1 C/O , 6Amp @ 230 AC (Resi.)
• Over voltage: Above 480 VAC
• Under voltage : Below 320 VAC
a P P l i c at i o n:MCC panels for sewage pump
(10.13.1) | LLC-101
sa l i e n t fe at u R e s :• Easy to install• DIN rail/ surface mountable• Two tank controller• Automatic control of starter according to set water level in tanks• LED indications for water level in tank• Specially for three phase motor starters• Available with S.S sensors/magnetic sensors/float switch• Engineering grade plastic enclosure (ABS)
te c h n i c a l s P e c i f i c at i o n s:• System Voltage: 415 VAC +/- 20 % , 50 Hz• Output : 1 CO contact ,1 Amp. At 415 VAC, Pf=0.5
a P P l i c at i o n:MCC of water pump in hotels, housed, high rise towers,
societies, industries, commercial complexes, municipal water stations
(10.13.2) | LLC-2
sa l i e n t fe at u R e s :• Easy to install• Surface mountable• Two tank controller• Automatic control of starter according to set water level in tanks• LED indications for water level in tank• Specially for single phase motor• Available with S.S sensors/magnetic sensors/float switch• Engineering grade plastic enclosure (ABS)
te c h n i c a l s P e c i f i c at i o n s:• System voltage: 230 VAC +/- 20 %, 50 Hz• Output voltage: 230 VAC +/- 20 %, 50 Hz• Capacity 30 A at 230 VAC ( Resi.)
a P P l i c at i o n:MCC panels of water pump in hotels, house, high rise towers, housing societies,
industries, commercial complexes, municipal water stations
WATER LEVEL CONTROLLER
30 31
(10.13.3) | LLC-2S
sa l i e n t fe at u R e s :• Easy to install• Two tank controller• Automatic control of starter according to set water level in tanks• LED indications for water level in tank• Specially for single phase submersible pumps, semi automatic
motor starters• Available with S.S sensors/magnetic sensors/float switch• Engineering grade plastic enclosure (ABS)
te c h n i c a l s P e c i f i c at i o n s:• System voltage: 230 VAC +/- 20 % , 50 Hz• Output voltage: 230 VAC+/- 20 %, 50 Hz
Capacity 30 A at 230 VAC ( Resi.)
a P P l i c at i o n:MCC panels of water pump in hotels, house, high rise towers, housing societies,
industries, commercial complexes, municipal water stations
(10.13.4) | LLC-001/LLC-001D
sa l i e n t fe at u R e s :• Water level controller adopter• Usefull with GELCO make single or three phase DOL or
FASD starters having adopter facility only• Easy to install• Surface mountable• Two tank controller• Automatic control of starter according to set water level in tanks• LED indications for water level in tank• Available with S.S sensors/magnetic sensors/float switch• Engineering grade plastic enclosure (ABS)• For GELCO starter having micro controller based technology use
LLC-001 D
a P P l i c at i o n:Motor starter of water pump in hotels, house, high rise
towers, housing societies, industries, commercial complexes,
municipal water stations
WATER LEVEL CONTROLLER
32